Herein, a tri-layered core-shell microfibrous scaffold with layer-specific growth factors (GFs) release is developed using coaxial electrohydrodynamic (EHD) printing for in situ cell recruitment and differentiation to facilitate gradient enthesis tissue repair. Our findings suggest that the microfibrous scaffolds with layer-specific GFs release may offer a promising clinical solution for enthesis regeneration. Utilizing coaxial electrohydrodynamic (EHD) printing, we engineered tri-layered core-shell microfibrous scaffolds, each layer tailored with specific growth factors (GFs) for targeted enthesis tissue repair. This configuration aims to sequentially guide cell migration and differentiation, mirroring the natural enthesis’ gradient structure. SDF-1 was strategically loaded into the shell, while bFGF, TGF-β, and BMP-2 were encapsulated in the core, each selected for their roles in stimulating the regeneration of corresponding enthesis tissue layers.Introduction
Method
The objective of the work is construction of a multi-bioactive scaffold based on that allows a space/time control over the regeneration of damaged bones by Medication-Related Osteonecrosis of the Jaw using a minimal invasive approach based on the injection of the fast-degrading pro neuro and angiogenic ELR (Elastin-Like Recombinamers) based hydrogels. Chemical crosslinking facilitated the creation of multi-bioactive scaffolds using ELRs with reactive groups. Cell-loaded multi-bioactive scaffolds, prepared and incubated, underwent evaluation for adhesion, proliferation, angiogenic, and neurogenic potential. In vitro assessments utilized immunofluorescence staining and ELISA assays, while live-recorded monitoring and live-dead analysis ensured cytocompatibility. In rat and rabbit models, preformed scaffolds were subcutaneously implanted, and the regenerative process was evaluated over time. Rabbit models with MRONJ underwent traditional or percutaneous implantation, with histological evaluation following established bone histological techniques.Introduction
Method
Understanding knee joint biomechanics is crucial, but studying Anterior cruciate ligament (ACL) biomechanics in human adolescents is challenging due to limited availability cadaveric specimens. This study aims to validate the adolescent porcine stifle joint as a model for ACL studies by examining the ACL's behavior under axial and torsion loads and assessing its deformation rate, stiffness, and load-to-failure. Human knee load during high-intensity sports can reach 5-6 times body weight. Based on these benchmarks, the study applied a force equivalent to 5-times body weight of juvenile porcine samples (90 pounds), estimating a force of 520N. Experiments involved 30 fresh porcine stifle joints (Yorkshire breed, Avg 90 lbs, 2-4 months old) stored at -22°C, then thawed and prepared. Joints were divided into three groups: control (load-to-failure test), axially loaded, and 30-degree torsion loaded. Using a servo-hydraulic material testing machine, the tibia's longitudinal axis was aligned with the load sensor, and specimens underwent unidirectional tensile loading at 1 mm/sec until rupture. Data on load and displacement were captured at 100 Hz.Introduction
Methods
Anterior shoulder instability results in labral and osseous glenoid injuries. With a large osseous defect, there is a risk of recurrent dislocation of the joint, and therefore the patient must undergo surgical correction. An MRI evaluation of the patient helps to assess the soft tissue injury. Currently, the volumetric three-dimensional (3D) reconstructed CT image is the standard for measuring glenoid bone loss and the glenoid index. However, it has the disadvantage of exposing the patient to radiation and additional expenses. This study aims to compare the values of the glenoid index using MRI and CT. The present study was a two-year cross-sectional study of patients with shoulder pain, trauma, and dislocation in a tertiary hospital in Karnataka. The sagittal proton density (PD) section of the glenoid and enface 3D reconstructed images of the scapula were used to calculate glenoid bone loss and the glenoid index. The baseline data were analyzed using descriptive statistics, and the Chi-square test was used to test the association of various complications with selected variables of interest.Introduction
Method
The surgical treatment of critical-sized bone defects with complex three-dimensional (3D) geometries is a challenge for the treating surgeon. Additive manufacturing such as 3D printing enables the production of highly individualized bone implants meeting the shape of the patient's bone defect and including a tunable internal structure. In this study, we showcase the design process for patient-specific implants with critical-sized tibia defects. Two clinical cases of patients with critical tibia defects (size 63×20×21 mm and 50×24×17 mm) were chosen. Brainlab software was used for segmentation of CT data generating 3D models of the defects. The implant construction involves multiple stages. Initially, the outer shell is precisely defined. Subsequently, the specified volume is populated with internal structures using Voronoi, Gyroid, and NaCl crystal structures. Variation in pore size (1.6 mm and 1.0 mm) was accomplished by adjusting scaffold size and material thickness.Introduction
Methods
The Achilles tendon is the thickest and strongest tendon in the human body. Even though the tendon is so strong, it is one of the most frequently injured tendons. Treatment of patients after rupture is planned conservatively and surgically. Conservative treatment is generally applied to elderly patients with sedentary lives. If the treatment is surgical, it can be planned as open surgery or percutaneous surgery. In our study with rabbits, we wrapped a membrane made of plga (polylactic-co-glycolic acid) nanotubes impregnated with type 1 collagen around the tendon in rabbits that underwent open Achilles tendon repair surgery. After surgery, biomechanical and histological tests were performed on the tendons. In the study consisting of 24 rabbits, 2 groups were created by random distribution. In the study group, after the Achilles tendon rupture was created, a type 1 collagen-impregnated plga-based membrane was placed around the tendon after the repair of 1 modified Kesslerr suture. In the control group, after the Achilles tendon rupture was created, 1 modified Kessler suture and Tendon repair was performed with the application of 3 primary sutures. At the end of the 6th week of the study, the rabbits in 2 groups were randomly distributed and histological examination was performed. Additionally, biomechanical testing was performed. Bonar and Movın scoring were used in histological examinations.Introduction
Method
Intervertebral disc (IVD) degeneration is not completely understood because of the lack of relevant models. In vivo models are inappropriate because animals are quadrupeds. IVD is composed of the Nucleus Pulposus (NP) and the Annulus Fibrosus (AF), an elastic tissue that surrounds NP. AF consists of concentric lamellae made of collagen I and glycosaminoglycans with fibroblast-like cells located between layers. In this study, we aimed to develop a novel 3D in vitro model of Annulus Fibrosus to study its degeneration. For this purpose, we reproduced the microenvironment of AF cells using 3D printing. An ink consisting of dense collagen (30 mg.mL-1) and tyramine-functionalized hyaluronic acid (THA) at 7.5 mg.mL-1 was first designed by modulating pH and [NaCl] in order to inhibit the formation of polyionic complexes between collagen and THA. Then, composite inks were printed in different gelling baths to form collagen hydrogels. Last, THA photocrosslinking using eosin and green light was performed to strengthen hydrogels. Selected 3D printed constructs were then cellularized with fibroblasts.INTRODUCTION
METHOD
Vascularized fibular grafting following tumor resection is an essential treatment option in limb salvage surgery. This study aimed to assess the surgical and oncological outcomes of patients treated in Denmark between 2010 and 2022. We present a retrospective review of a national cohort comprising 27 patients. The indications were 13 cases of Ewing sarcoma, 12 cases of osteosarcoma, and 2 cases of giant cell tumor. The median age at surgery was 16 years (range: 2-39), and the median follow-up was 82 months (range: 12-138). Patients were analyzed overall and stratified into upper and lower extremity groups based on tumor location.Introduction
Method
The non-union of long bones poses a substantial challenge to clinicians and patients alike. The Ilizarov fixation system and Limb Reconstruction System (LRS), renowned for their versatility in managing complex non-unions. The purpose of this retrospective study was to assess the outcomes of acute docking with the bone peg-in-bone technique for the management of non-unions of long bones. The study seeks to evaluate its effectiveness in achieving complete bony union, preserving limb length and alignment, correcting existing deformities, and preventing the onset of new ones. A retrospective analysis of 42 patients was done with infected and non-infected non-unions of long bones who received treatment at a tertiary care hospital between April 2016 to April 2022. We utilized the Association for the Study and Application of Methods of the Ilizarov (ASAMI) scoring system to assess both bone and functional outcomes and measured mechanical lateral distal femoral angle (mLDFA) for the femur and the medial proximal tibial angle (MPTA) for the tibia.Introduction
Method
Assessment of the humeral head translation with respect to the glenoid joint, termed humeral head migration (HHM), is crucial in total shoulder arthroplasty pre-operative planning. Its assessment informs current classification systems for shoulder osteoarthritis as well as the evaluation of surgical correction. In current clinical practice, HHM assessment relies on computed-tomography (CT) imaging. However, the associated supine position might undermine its functional relevance as it does not reflect the weight-bearing condition with active muscle engagement associated with the upright standing position of most daily activities. Therefore, we assessed to what extent HHM in a supine position is associated with HHM in a range of functional arm positions. 26 shoulder osteoarthritis patients and 12 healthy volunteers were recruited. 3D shapes of the humerus and scapula were reconstructed from their respective CT scans using an image processing softwareIntroduction
Method
Intraoperative navigation systems for lumbar spine surgery allow to perform preoperative planning and visualize the real-time trajectory of pedicle screws. The aim of this study was to evaluate the deviation from preoperative planning and the correlations between screw deviation and accuracy. Patients affected by degenerative spondylolisthesis who underwent posterior lumbar interbody fusion using intraoperative 3D navigation since April 2022 were included. Intraoperative cone-beam computed tomography (CBCT) was performed before screw planning and following implantation. The deviation from planning was calculated as linear, angular, and 3D discrepancies between planned and implanted screws. Accuracy and facet joint violation (FJV) were evaluated using Gertzbein-Robbins system (GRS) and Yson classification, respectively. Statistical analysis was performed using SPSS version28. One-way ANOVA followed by Bonferroni post-hoc tests were performed to evaluate the association between GRS, screw deviation and vertebral level. Statistical significance was set at p<0.05.Introduction
Method
Inaccurate identification of implants on X-rays may lead to prolonged surgical duration as well as increased complexity and costs during implant removal. Deep learning models may help to address this problem, although they typically require large datasets to effectively train models in detecting and classifying objects, e.g. implants. This can limit applicability for instances when only smaller datasets are available. Transfer learning can be used to overcome this limitation by leveraging large, publicly available datasets to pre-train detection and classification models. The aim of this study was to assess the effectiveness of deep learning models in implant localisation and classification on a lower limb X-ray dataset. Firstly, detection models were evaluated on their ability to localise four categories of implants, e.g. plates, screws, pins, and intramedullary nails. Detection models (Faster R-CNN, YOLOv5, EfficientDet) were pre-trained on the large, freely available COCO dataset (330000 images). Secondly, classification models (DenseNet121, Inception V3, ResNet18, ResNet101) were evaluated on their ability to classify five types of intramedullary nails. Localisation and classification accuracy were evaluated on a smaller image dataset (204 images).Introduction
Method
In daily clinical practice, progression of spinal fusion is typically monitored during clinical follow-up using conventional radiography and Computed Tomography scans. However, recent research has demonstrated the potential of implant load monitoring to assess posterolateral spinal fusion in an in-vivo sheep model. The question arises to whether such a strain sensing system could be used to monitor bone fusion following lumbar interbody fusion surgery, where the intervertebral space is supported by a cage. Therefore, the aim of this study was to test human cadaveric lumbar spines in two states: after a transforaminal lumbar interbody fusion (TLIF) procedure combined with a pedicle-screw-rod-construct (PSR) and subsequently after simulating bone fusion. The study hypothesized that the load on the posterior instrumentation decreases as the segment stiffens due to simulated fusion. A TLIF procedure with PSR was performed on eight human cadaveric spines at level L4-L5. Strain sensors were attached bilaterally to the rods to derive implant load changes during unconstrained flexion-extension (FE), lateral bending (LB) and axial rotation (AR) loads up to ±7.5Nm. The specimens were retested after simulating bone fusion between vertebrae L4-L5. In addition, the range of motion (ROM) was measured during each loading mode.Introduction
Method
Tibiocalcaneal arthrodesis with a retrograde intramedullary nail is an established procedure considered as a salvage in case of severe arthritis and deformity of the ankle and subtalar joints [1]. Recently, a significant development in hindfoot arthrodesis with plates has been indicated. Therefore, the aim of this study was to compare a plate specifically developed for arthrodesis of the hindfoot with an already established nail system [2] Sixteen paired human cadaveric lower legs with removed forefoot and cut at mid-tibia were assigned to two groups for tibiocalcaneal arthrodesis using either a hindfoot arthrodesis nail or an arthrodesis plate. The specimens were tested under progressively increasing cyclic loading in dorsiflexion and plantar flexion to failure, with monitoring via motion tracking. Initial stiffness was calculated together with range of motion in dorsiflexion and plantar flexion after 200, 400, 600, 800, and 1000 cycles. Cycles to failure were evaluated based on 5° dorsiflexion failure criterionIntroduction
Method
Identification of the causative pathogen in musculoskeletal infection is critical as it directs further treatment. Fracture-related infection is often associated with ‘no growth’ in standard culture. We investigated the efficiency of two alternate methods to identify the causative pathogen, namely extended bacterial culture and 16Sr RNA gene sequence analysis with next generation sequencing (NGS) in ‘culture negative’ fracture related infections. Patients were diagnosed as having fracture related infection based on the MSIS criteria (n=120). All patients had samples taken for culture and sensitivity. All samples which were culture negative by standard culture methods formed the study group. These samples were subjected to further extended culture in both aerobic and anaerobic medium for 14 days to improve recovery of pathogens. Further, DNA isolated from implants from a sub-group of these culture negative patients were subjected to 16SrRNA gene amplification followed by Sanger sequencing. Subsequent sequencing analysis was performed using the Illumina NGS platform which identified and detected the most abundant genera/species present in those samples more precisely.Introduction
Method
To compare postoperative clinical outcomes between posterior cruciate ligament (PCL) retaining and resecting total knee arthroplasty (TKA) using same cruciate-substituting (CS) inserts, and to elucidate the clinical relevance of the residual PCL in cruciate-retaining TKA, considering intraoperative influence factors, such as the posterior tibial slope, posterior condylar offset, joint gap, joint balance, and joint laxity. A total of 64 consecutive knees (44 patients) were enrolled in this study and divided into following two groups: 39 knees underwent PCL-retaining TKA group (CR group), and 25 underwent PCL-resecting TKA group (CS group). Preoperative patients’ demographic data and one-year postoperative clinical outcomes including range of motion, the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Japanese Orthopaedic Association (JOA) score, and Forgotten Joint Score-12 (FJS-12) were compared between two groups.Purpose
Methods
Research studies have established mathematical correlations between the lengths of bone segments and the possible biomechanical implications of these correlations. The Lucas sequence comprises a series of integers that adhere to the same recurrence relation as the Fibonacci sequence; it differs in that it can start with any two initial integers. The purpose of this study is to determine whether segmental lengths of the foot height, tibia, femur, and upper body follow a Lucas sequence pattern. This was a retrospective radiographic review of patients who underwent full-body EOS scans. The AP scan was used to measure standing foot height (Ft), tibial length (T), femoral length (Fe), upper body length (UB), and full body length. A linear regression test was performed to determine whether a Lucas sequence-based relationship exists between Ft + T and Fe, and between T + Fe and UB.Introduction
Method
Shared decision making (SDM) was introduced in hospital Lillebelt in 2019 and research reports that patients are more satisfied with their treatment, if they play an active role in choosing treatment. A Decision-Helper was constructed and introduced in the treatment for Colles fractures. This study aimed to understand how patients experience shared decision-making (SDM) for an acute illness, and how it affects them when making decisions about the treatment of their distal radius fracture. An exploratory, qualitative study design was performed to understand the patient's experience, during the choice of treatment with SDM. 12 were recruited when they came to their first follow-up 5 days after the injury, in the outpatient clinic. 10 were interviewed; 3 face to face and 7 by telephone. All women aged 57-87 years and all had a displaced Colles fracture, which had been reduced in the Emergency Room.Introduction
Method
Femoral head osteonecrosis (FHO) is a condition in which the inadequate blood supply disrupts osteogenic-angiogenic coupling that results in diminishment of femoral perfusion and ends up with FHO. The insufficient knowledge on molecular background and progression pattern of FHO and the restrictions in obtaining human samples bring out the need for a small animal trauma model to research FHO aetiology. Hence, this study aims to develop a mouse trauma model to elucidate the molecular mechanisms behind FHO. Left femoral head was dislocated from the hip joint, ligamentum teres was cut, and a slight circular incision was done around the femoral neck of 8-week-old male C57BL/6J mice to disrupt the blood supply to femoral head. Right hip joint was left unoperated as control. Animals (n=5 per time point) were sacrificed on 2-3-4-6-8-10-12 weeks, and ex-vivo µCT was taken to assess bone structural parameters. Haematoxylin/eosin (HE)- and immunohistochemical-staining (IHCS) for CD31 and EMCN were done to observe histology and marrow-specific H-type vascular structures, respectively.Introduction
Method
Cephalomedullary nails are widely used for fixation of unstable pertrochanteric fractures. In 2018, the Depuy Synthes Trochanteric Fixation Nail - Advanced (TFNA) implant was introduced at a level I academic trauma center. Thereafter, the TFNA swiftly replaced the older implant models used at the time. Subsequently, clinical concerns were raised about the use of the TFNA due to reports of nail breakage. The purpose of this study was to investigate whether the concerns raised about the performance of the TFNA were valid and to assess long-term outcomes. The data consisted of 2397 patients who had undergone a proximal femoral hip fracture procedure between 2014 and 2020. Data were handpicked from patient records. TFNA was compared with TFN, PFNA, Gamma3, and Intertan regarding nail breakage, breakage time and long-term outcomes.Background
Methods