Limited information is available regarding the functional outcomes of radial head fractures managed with open reduction and internal fixation (ORIF). The purpose of this study was to determine the functional outcomes of radial head fractures treated with ORIF. Fifty-two patients, with a mean age of 4412 years, who were treated with radial head ORIF were evaluated at a mean of 4.42.4 years. Thirty were isolated radial head fractures (Group A), 13 (Group B) were associated with a complex fracture-dislocation (terrible triad variants), and 5 (Group C) were associated with a proximal ulnar fracture (Monteggia/trans-olecranon variants). Fourty-four were partial articular fractures and 8 were complete articular fractures. Outcomes were assessed with physical and radiographic examination, and validated self-reported questionnaires.Purpose
Method
Radial head implant over-lengthening, a common cause of capitellar wear and clinical failure, is difficult to diagnose using radiographs of the injured elbow. The purpose of this study was to determine if a novel measurement technique based on contralateral elbow radiographs, termed the RACER method, could be used to accurately estimate the magnitude of radial head implant over-lengthening. Part I of this study examined the side-to-side consistency of radiographic landmarks used in the measurement technique. Part II of this study validated the technique using simulated radial head implant over-lengthening in a cadaveric model. Part I: A side-to-side comparison of elbow joint dimensions was performed in 50 patients (100 radiographs). Part II: Radial head prostheses of varying lengths (0,+2mm,+4mm,+6mm,+8mm) were implanted in 4 paired cadaveric specimens (8 elbows). Radiographs were obtained and measurements were performed by 2 examiners blinded to implant size to determine if contralateral radiographs could diagnose and provide a valid estimate of the magnitude of implant over-lengthening. Intra and inter-rater reliability was determined.Purpose
Method
There have been a number of described techniques for sizing the diameter of radial head implants. All of these techniques, however, are dependent on measurements of the excised native radial head. When accurate sizing is not possible due to extensive comminution or due to a previous radial head excision, it has been postulated that the proximal radioulnar joint (PRUJ) may be used as an intraoperative landmark for correct sizing. The purpose of this study was to: 1) determine if the PRUJ could be used as a reliable landmark for radial head implant diameter sizing when the native radial head in unavailable, and (2) determine the reliability of measurements of the excised radial head. Twenty-seven fresh-frozen denuded ulnae and their corresponding radial heads (18 males, 9 females) were examined. The maximum diameter (MaxD), minimum diameter (MinD) and dish diameter (DD) of the radial heads were measured twice, 3–5 weeks apart, using digital calipers. Two fellowship-trained upper extremity surgeons, an upper extremity fellow and a senior orthopedic resident were then asked to independently select a radial head implant diameter based on the congruency of the radius of curvature of the PRUJ to that of the radial head trial implants. The examiners were blinded to the native radial head dimensions. This selection was repeated 3–5 weeks later by two of the investigators. Correlation between radial head measurements and radial head implant diameter sizes was assessed using Pearsons correlation coefficient (PCC) and inter and intra-observer reliability were assessed using intra-class correlation coefficient (ICC).Purpose
Method
Current coronoid fracture classification systems are based on fragment size and configuration using plain radiographs and/or CT. During surgery, coronoid fracture fragments appear much larger than anticipated because cartilage is radiolucent and therefore not taken into account with preoperative imaging. The purpose of this study was to quantify the articular cartilage thickness of the coronoid process, with reference to coronoid fracture classifications. Twenty-four cadaveric ulnae were dissected, imaged, and analyzed using the OsiriX software program (3.6–64 bit, Geneva). Thirteen identifiable landmarks were chosen on the coronoid, olecranon and proximal radioulnar joint to measure articular cartilage thickness. Intra-observer and inter-observer reliability were calculated.Purpose
Method
The coronoid process is an integral component for elbow stability. In the setting of a comminuted coronoid fracture, where repair is not possible, a prosthetic device may be beneficial in restoring elbow stability. The hypothesis of this in-vitro biomechanical study was that an anatomic coronoid prosthesis would restore stability to the coronoid deficient elbow. A metal coronoid prosthesis was designed and developed based on CT-derived images adjusted for cartilage thickness. The kinematics and stability of eight fresh-frozen male cadaveric arms (mean age 77.4 years, range 69–92 years) were quantified in the intact state; after collateral ligament sectioning and repair (control state); after a simulated 40% transverse coronoid fracture; and after implantation of a coronoid prosthesis. Elbow flexion was simulated passively with the arm oriented in the varus position and the forearm in pronation. Varus-valgus angulation (VV) and internal-external rotation (IE) of the ulna relative to the humerus were quantified with an electromagnetic tracking system (Flock of Birds, Ascension Technologies, Burlington, VT, static accuracy: 1.8mm position, 0.5 orientation).Purpose
Method
Capitellum hemiarthroplasty is an emerging concept. The current metallic capitellar implants have spherical surface shapes, but the native capitellum is not spherical. This study evaluated the effect of capitellar implant shape on the contact mechanics of the radiocapitellar joint when articulating with the native radial head. Eight paired radii and humeri were potted in a custom jig. Articular casts were made with medium-viscosity resin while 85 N of axial load was applied to the reduced radiocapitellar joint at 0, 45, and 90 of elbow flexion, and at neutral, 50 pronation and 50 supination at each flexion angle. The native radiocapitellar articulation was compared to capitellar hemiarthroplasties of two surface designs (anatomical and spherical). Contact area and shape (circularity) were determined. Circularity was defined as the ratio of the minor axis and major axis of the shape.Purpose
Method
Release of tight lateral structures is an integral part of balancing the valgus knee during knee replacement surgery. The posterolateral capsule is released through an inside-out technique. The common peroneal nerve is in close proximity to the capsule during this step. This study was undertaken to determine the distance of the nerve and the safe level for the posterolateral release. MR scans of the knee of 100 patients were evaluated. The age range of selected patients was 50 to 70 years. The distance of the nerve was measured to the closest point on the posterolateral capsule. Two separate measurements were taken - one 9mm above the joint line indicating the distal femoral resection level and the other 9mm distal to the joint line indicating the level of tibial resection. A third point was at the joint line level. The position of the nerve was also recorded in relation to the cross section of the femur/tibia on a ‘clock-like’ reference.Purpose of the study
Methods
Rapid prototyping (RP), especially useful in surgical specialities involving critical three-dimensional relationships, has recently become cheaper to access both in terms of file processing and commercially available printing resources. One potential problem has been the accuracy of models generated. We performed computed tomography on a cadaveric human patella followed by data conversion using open source software through to selective-laser-sintering of a polyamide model, to allow comparative morphometric measurements (bone No significant differences in the dimensional measurements could be demonstrated. These data provide us with optimism as to the accuracy of the technology, and the feasibility of using RP cheaply to generate appropriate models for operative rehearsal of intricate orthopaedic procedures.
Hip resurfacing arthroplasty is an established and effective intervention for osteoarthritis of the hip in the young active patient, relying on the principle of femoral bone-stock preservation. A recognised mode of failure is neck thinning leading to radiological evidence of neck collapse and clinical failure. We report on a series of these slow-neck-failure patients and highlight the increased incidence of this phenomenon in post-menopausal female patients. This is a single operator, single implant series; 172 cases were identified from databases at our institution. 76 were female, mean (SD) age 52 (7) years. 96 were male, mean (SD) age 51(12) years. 15 (8.7%) patients required revision. 12 (80%) were female, 9 (75%) of these were due to slow neck failure. In the men one patient developed ALVAL requiring removal of his bilateral hip resurfacings, the other failure mode was early femoral neck failure. Mean time to failure was 6 months in men and 37 months in women. This difference in failure rates is also seen in the NJR figures. This review confirms the relatively high incidence of premature failure in post-menopausal females. NICE guidance in 2003, currently under review, stated that resurfacing is indicated in male patients up to 65 and female patients up to 60. As a result of this study we are currently advising post-menopausal patients that this risk of early failure may make total hip replacement a preferable option to resurfacing arthroplasty.
Osteonecrosis (ON) is a disease that ultimately results in bone collapse. We investigated the correlation between SNPs and osteonecrosis. In this study, 109 patients with systematic lupus erythematosus (SLE) (21 with and 88 without osteonecrosis) were collected for genotype analysis of 7 genes including Introduction
Methods
We carried out a prospective investigation into
the radiological outcomes of uncemented Oxford medial compartment
unicondylar replacement in 220 consecutive patients (231 knees)
performed in a single centre with a minimum two-year follow-up.
The functional outcomes using the mean Oxford knee score and the
mean high-activity arthroplasty score were significantly improved
over the pre-operative scores (p <
0.001). There were 196 patients
with a two-year radiological examination performed under fluoroscopic
guidance, aiming to provide images acceptable for analysis of the
bone–implant interface. Of the six tibial zones examined on each
knee on the anteroposterior radiograph, only three had a partial
radiolucent line. All were in the medial aspect of the tibial base plate
(zone 1) and all measured <
1 mm. All of these patients were
asymptomatic. There were no radiolucent lines seen around the femoral
component or on the lateral view. There was one revision for loosening
at one year due to initial inadequate seating of the tibial component.
These results confirm that the early uncemented Oxford medial unicompartmental
compartmental knee replacements were reliable and the incidence
of radiolucent lines was significantly decreased compared with the
reported results of cemented versions of this implant. These independent
results confirm those of the designing centre.
Osteonecrosis (ON) is one of the most debilitating skeletal disorders. Most patients with ON of the femoral head eventually require surgery, usually total hip arthroplasty, within a few years of disease onset. Previous reports have shown that alendronate reduces osteoclastic activity and reduces the incidence of femoral head collapse in osteonecrotic hips. A randomized study to examine the ability of alendronate to delay or prevent femoral head collapse was performed. From June 2005 to December 2006, sixty four patients were enrolled and randomly assigned to alendronate or placebo. Five patients were excluded from the analysis because of their failure to adhere to the study protocol. Disease progression was evaluated using radiographs and magnetic resonance imaging (MRI).Introduction
Methods
Controversy surrounds the most appropriate treatment
method for patients with a rupture of the tendo Achillis. The aim
of this study was to assess the long term rate of re-rupture following
management with a non-operative functional protocol. We report the outcome of 945 consecutive patients (949 tendons)
diagnosed with a rupture of the tendo Achillis managed between 1996
and 2008. There were 255 female and 690 male patients with a mean
age of 48.97 years (12 to 86). Delayed presentation was defined
as establishing the diagnosis and commencing treatment more than
two weeks after injury. The overall rate of re-rupture was 2.8%
(27 re-ruptures), with a rate of 2.9%
(25 re-ruptures) for those with an acute presentation and 2.7% (two
re-ruptures) for those with delayed presentation. This study of non-operative functional management of rupture
of the tendo Achillis is the largest of its kind in the literature. Our
rates of re-rupture are similar to, or better than, those published
for operative treatment. We recommend our regime for patients of
all ages and sporting demands, but it is essential that they adhere
to the protocol.
We have investigated whether the use of laminar-flow theatres and space suits reduced the rate of revision for early deep infection after total hip (THR) and knee (TKR) replacement by reviewing the results of the New Zealand Joint Registry at ten years. Of the 51 485 primary THRs and 36 826 primary TKRs analysed, laminar-flow theatres were used in 35.5% and space suits in 23.5%. For THR there was a significant increase in early infection in those procedures performed with the use of a space suit compared with those without (p <
0.0001), in those carried out in a laminar-flow theatre compared with a conventional theatre (p <
0.003) and in those undertaken in a laminar-flow theatre with a space suit (p <
0.001) when compared with conventional theatres without such a suit. The results were similar for TKR with the use of a space suit (p <
0.001), in laminar-flow theatres (p <
0.019) and when space suits were used in those theatres (p <
0.001). These findings were independent of age, disease and operating time and were unchanged when the surgeons and hospital were analysed individually. The rate of revision for early deep infection has not been reduced by using laminar flow and space suits. Our results question the rationale for their increasing use in routine joint replacement, where the added cost to the health system seems to be unjustified.
A longer stay in the hospital after primary total hip replacement is consistent with an increased morbidity and slower recovery for patients. In addition, it is among the more costly aspects of a total joint replacement. A process, which reduces the length of stay following this procedure and synchronically maintains the high standards of safe care would certainly improve the clinical practice and provide financial benefits. Our objective was to evaluate the efficiency of a holistic perioperative, accelerated recovery programme following this procedure and in particular to assess its impact in the shot term patient’s recovery, morbidity, complications, readmission rate and cost savings for the NHS. Eighty-nine patients participated in our rapid recovery programme, which is a comprehensive approach to patient care, combining individual pre-operative patient education, pain management, infection control, continuous nursing and medical staff motivation as well as intensive physiotherapy in the ward and the community. Forty-eight male and 41 female patients with an average age of 69 (range-50 to 87) underwent a total hip replacement in an NHS District General Hospital. The average BMI was 28 (range-18 to 39) and the average ASA 2.3 (range-1 to 4). The procedure was performed by 3 different surgeons using the same operative standards. A standardised post-operative protocol was followed and the patients were discharged when they were medically fit and had achieved the ward physiotherapy requirements. They were then daily followed up by a community orthopaedic rehabilitation team in patient’s own environment as long as it was required. The average length of stay was reduced from 7.8 days to 5. There was no increase in complications–or readmissions rate while there were significant cost savings. The waiting list for this surgery was reduced and the patient’s satisfaction was high. The rapid recovery programme for primary total hip replacement surgeries has been proved to be an efficient method of reducing the length of stay in hospital and consequently the financial costs while it ensures the safe and effective peri-operative management of patients.
We reviewed the rate of revision of unicompartmental knee replacements (UKR) from the New Zealand Joint Registry between 1999 and 2008. There were 4284 UKRs, of which 236 required revision, 205 to a total knee replacement (U2T) and 31 to a further unicompartmental knee replacement (U2U). We used these data to establish whether the survival and functional outcome for revised UKRs were comparable with those of primary total knee replacement (TKR). The rate of revision for the U2T cohort was four times higher than that for a primary TKR (1.97 The poor outcome of a UKR converted to a primary TKR compared with a primary TKR should contra-indicate the use of a UKR as a more conservative procedure in the younger patient.
We analysed data from the Oxford hip and knee questionnaires collected by the New Zealand Joint Registry at six months and five years after joint replacement, to determine if there was any relationship between the scores and the risk of early revision. Logistic regression of the six-month scores indicated that for every one-unit decrease in the Oxford score, the risk of revision within two years increased by 9.7% for total hip replacement (THR), 9.9% for total knee replacement (TKR) and 12.0% for unicompartmental knee replacement (UKR). Our findings showed that 70% of the revisions within two years for TKR and 67% for THR and UKR would have been captured by monitoring the lowest 22%, 28% and 28%, respectively, of the Oxford scores. When analysed using the Kalairajah classification a score of <
27 (poor) was associated with a risk of revision within two years of 7.6% for THR, 7.0% for TKR and 24.3% for UKR, compared with risks of 0.7%, 0.7% and 1.8%, respectively, for scores >
34 (good or excellent). Our study confirms that the Oxford hip and knee scores at six months are useful predictors of early revision after THR and TKR and we recommend their use for the monitoring of the outcome and potential failure in these patients.
It is established good practice that joint replacements should have regular follow-up and for the past seven years at the North Hampshire Hospital a local joint register has been used for this purpose and we compare this with results of the Swedish and UK national registries. Since March 1999, all primary and revision knee arthroplasties performed at North Hampshire Hospital, Basingstoke have been prospectively recorded onto a database set up by one of the senior authors (JMB). Data from patients entered in the first six years of the register were analysed. All patients have at least one year clinical and radiological review then a minimum of yearly postal follow-up. As of 31/12/2006, 2854 knee replacement procedures had been performed under the care of 13 consultants. OA was the most common diagnosis in over 75% of knees. 5.2% of patients had died and 4.6% were lost to follow-up. Our revision burden was 3.5% and we had a revision rate of 1.4% for primary total knee replacements. Audit of data for revisions and patello-femoral replacements has enabled us to change our practices. Mean length of stay was 7.2 days for primary total knee arthroplasty versus 4.0 days for unicompartmental knee arthroplasty and 5.4 days for patellofemoral replacement and mean flexion at discharge was 88.4, 93.7 and 88.7 degrees respectively. WOMAC and Oxford scores at 2 years had improved from a mean of 52 and 21 pre-operatively to 74 and 39 respectively for primary total knee arthroplasty. Our costs are estimated at approximately £35 per patient for their lifetime on the register. Compared to other registries:
Our dataset is more complete and comprehensive Our costs are less All patients have a unique identifier (at least 19% of UKNJR data is anonymous) Our audit loops have been closed
Stress shielding (i.e. reduction in bone strains) in the distal ulna is commonly noted following ulnar head replacement arthroplasty. Optimal design parameters for distal ulnar implants, including the length of the stem, are currently unknown. The purpose of this study was to investigate the effect of stem length on bone strains along the length of the ulna. Strain gauges were applied to each of eight cadaveric ulnae to measure bending loads at six locations along each ulna’s length (approximately 1.5, 2.5, 4.0, 6.0, 8.0, and 13.0cm from the ulnar head). The proximal portion of each bone was secured in a custom-designed jig. A materials testing machine applied loads (5–30N) to the ulnar head while native strains were recorded. The ulnar head was removed and the loading procedure repeated for cemented stainless steel stems 3 and 7cm in length, according to a previously reported technique (Austman et al, CORS 2006). Other stem lengths between 3 and 7cm were tested in 0.5cm intervals with a 20N load applied only. Data were analyzed using a two-way repeated measures ANOVA (á=0.05). In general, distal bone strains increased as stem length decreased (e.g. average microstrains at the second distal-most gauges: 138±13 (7cm), 147±15 (6cm), 159±21 (5cm), 186±40 (4cm), 235±43 (3cm)). The native strains were different from all stem lengths for the four distal-most gauges (p<
0.05). No differences were found between any stem length and the native bone at the two proximal-most gauges. The 3cm stem replicated the native strains more closely than the 7cm, over all applied loads (e.g. average microstrains at the third gauge level for a 25N load: 357±59 (native), 396±74 (3cm), 257±34 (7cm)). No stem length tested matched the native strains at all gauge locations. The 3cm stem results were closer to the native strains than the 7cm stem for all loads at gauges overtop of the stem. Overall, the 3cm stem produced the highest strains, and thus would likely result in less distal ulnar bone resorption after implantation. These results suggest that shorter (approximately 3cm) stems should be considered for distal ulnar implants to potentially reduce stress shielding, although this must be balanced by adequate stem length for fixation.
We have reviewed the rate of revision of fully cemented, hybrid and uncemented primary total hip replacements (THRs) registered in the New Zealand Joint Registry between 1999 and December 2006 to determine whether there was any statistically significant difference in the early survival and reason for revision in these different types of fixation. The percentage rate of revision was calculated per 100 component years and compared with the reason for revision, the type of fixation and the age of the patients. Of the 42 665 primary THRs registered, 920 (2.16%) underwent revision requiring change of at least one component. Fully-cemented THRs had a lower rate of revision when considering all causes for failure (p <
0.001), but below the age of 65 years uncemented THRs had a lower rate (p <
0.01). The rate of revision of the acetabular component for aseptic loosening was less in the uncemented and hybrid groups compared with that in the fully cemented group (p <
0.001), and the rate of revision of cemented and uncemented femoral components was similar, except in patients over 75 years of age in whom revision of cemented femoral components was significantly less frequent (p <
0.02). Revision for infection was more common in patients aged below 65 years and in cemented and hybrid THRs compared with cementless THRs (p <
0.001). Dislocation was the most common cause of revision for all types of fixation and was more frequent in both uncemented acetabular groups (p <
0.001). The experience of the surgeon did not affect the findings. Although cemented THR had the lowest rate of revision for all causes in the short term (90 days), uncemented THR had the lowest rate of aseptic loosening in patients under 65 years of age and had rates comparable with international rates of aseptic loosening in those over 65 years.
All patients were evaluated prior to surgery. The patients with coexisting inflammatory disease or peri-prosthetic fracture were also evaluated. A hip was diagnosed as infected on the basis of positive intra operative microbiology samples three or more out of five and or histological evidence.
To determine the ten-year survivorship of the Original M E Muller Straight Stem Total Hip Replacement System with emphasis on the longevity of the femoral component in accordance with guidelines published by the National Institute of Clinical Excellence, 266 consecutive hip arthroplasties using the above prosthesis were performed by the senior author between 1983 and 1992. 24 patients were lost to follow-up. Of the remaining 242 patients 80 were male and 162 female. The mean age was 67.49 years. The diagnosis for the majority of patients was osteoarthritis of the hip joint. Pre-operative planning was carried out and the patients were scored using Charnley’s modification of the d’ Aubigne and Postel numerical grading system A mono-bloc stem with a 32-millimeter head used via the trans gluteal approach recommended by Muller. Following discharge serial follow-up consisted of both clinical and radiological evaluation. The data was prospectively stored on a Microsoft access database. The survival of the prosthesis using revision for aseptic loosening as an end-point was calculated by actuarial analysis. 135 patients attended their ten-year follow-up. 97% of patients had good to excellent pain relief and improvement in movement of the joint following surgery. 38% had good to excellent mobility with the remaining having restricted mobility due to associated co-morbid factors. Only in 3% of patients was mobility restricted as a result of the arthroplasty. 7 revisions were carried out for aseptic loosening, all as a result of failure of the acetabular component. The cumulative survival for this hip replacement system was 95.9% and that for the femoral component was 100% at 10 years. The Muller Straight Stem femoral component is based on a press-fit concept and gives predictable long-term results when recommended surgical technique is followed. This series confirms the reliability of the stem design and satisfies the NICE guidelines.
This in-vitro study was conducted to determine the effect of rotator cuff tears on joint kinematics. A shoulder simulator produced unconstrained active abduction of the humerus. Three sequential 1cm lesions were created, the first two in the supraspinatus tendon and the third in the subscapularis tendon. The plane of abduction moved posteriorly and became more abnormal throughout abduction as the size of the tear increased. It is concluded that in order to generate the same motions achieved by the intact joint other muscle groups must be employed, inevitably resulting in altered joint loading. This in-vitro study was conducted to determine the effect of simulated progressive tears of the rotator cuff on active glenohumeral joint kinematics. Five cadaveric shoulders were tested using a shoulder simulator designed to produce unconstrained active motion of the humerus. Forces were applied to simulate loading of the supraspinatus, subscapularis, infraspinatus/teres minor, anterior, middle, and posterior deltoid muscles based upon variable ratios of electromyographic data and average physiological cross-sectional area of the muscles. Three sequential 1cm lesions were created, the first two in the supraspinatus tendon and the third in the subscapularis tendon. Simulated active glenohumeral abduction was performed following the creation of each lesion. Five successive tests were performed to quantify repeatability. The plane of abduction moved posteriorly and became more abnormal throughout abduction as the size of the lesion increased (p=0.01) (Figure 1). In order to generate the same motions achieved with an intact rotator cuff other muscle groups must be employed, inevitably resulting in altered joint loading. A better understanding of the effects that rotator cuff tears have on the kinematics of the glenohumeral joint may result in the development of innovative rehabilitation strategies to compensate for this change in muscle balance and improve the clinical outcomes. Please contact author for diagram and/or graph.
The generally-accepted treatment for large, displaced fractures of the glenoid associated with traumatic anterior dislocation of the shoulder is operative repair. In this study, 14 consecutive patients with large (>
5 mm), displaced (>
2 mm) anteroinferior glenoid rim fractures were treated non-operatively if post-reduction radiographs showed a centred glenohumeral joint. After a mean follow-up of 5.6 years (2.8 to 8.4), the mean Constant score and subjective shoulder value were 98% (90% to 100%) and 97% (90% to 100%), respectively. There were no redislocations or subluxations, and the apprehension test was negative. All fragments healed with an average intra-articular step of 3.0 mm (0.5 to 11). No patient had symptoms of osteoarthritis, which was mild in two shoulders and moderate in one. Traumatic anterior dislocation of the shoulder, associated with a large displaced glenoid rim fracture can be successfully treated non-operatively, providing the glenohumeral joint is concentrically reduced on the anteroposterior radiograph.
Allografts of bone from the femoral head are often used in orthopaedic procedures. Although the donated heads are thoroughly tested microscopically before release by the bone bank, some surgeons take additional cultures in the operating theatre before implantation. There is no consensus about the need to take these cultures. We retrospectively assessed the clinical significance of the implantation of positive-cultured bone allografts. The contamination rate at retrieval of the allografts was 6.4% in our bone bank. Intra-operative cultures were taken from 426 femoral head allografts before implantation; 48 (11.3%) had a positive culture. The most frequently encountered micro-organism was coagulase-negative staphylococcus. Deep infection occurred in two of the 48 patients (4.2%). In only one was it likely that the same micro-organism caused the contamination and the subsequent infection. In our study, the rate of infection in patients receiving positive-cultured allografts at implantation was not higher than the overall rate of infection in allograft surgery suggesting that the positive cultures at implantation probably represent contamination and that the taking of additional cultures is not useful.
We present four patients who had sustained a traumatic dislocation of the atlanto-occipital joint. The diagnosis was initially missed in two patients. One patient, who was neurologically intact, was treated non-operatively. The remaining three recovered neurologically after an occipitocervical fusion. Early recognition of the injury, especially in multiply-injured patients with head injuries, and timely management may improve survival and neurological recovery.
We prospectively investigated a consecutive series of ten patients undergoing a cemented primary total hip replacement (THR) for osteoarthritis in order to establish the elution characteristics of Simplex-tobramycin bone cement (Howmedica, Limerick, Ireland). Specimens of blood, urine and drainage fluid were collected for 72 hours postoperatively. Very high concentrations of tobramycin were found in the drainage fluid, with mean levels at one hour of 103 mg/l, which steadily declined to 15.1 mg/l after 48 hours. The mean serum tobramycin levels reached a peak of 0.94 mg/l at three hours and declined rapidly to 0.2 mg/l by 48 hours. The mean urinary tobramycin levels peaked at 57.8 mg/l at 12 hours with a rapid decline to 12.6 mg/l by 24 hours. There was a direct correlation between the amount of tobramycin bone cement which was implanted and the amount of tobramycin systemically absorbed. Excellent local delivery was achieved with minimal systemic concentrations. Simplex-tobramycin bone cement is an efficient and safe method for the delivery of antibiotics after THR.
Among two hundred and twenty hemivertebrae in our files we performed over a period of eighteen years sixty nine hemivertebrae (HV) excision. Only H.V. with evidence of curve progression were operated on. The technique was a one stage anterior and posterior approach plus convex anterior and posterior arthrodesis plus convex posterior instrumentation using in the more recents cases a baby C.D. Material: The location of the H.V. was thoraco-lumbar in twenty five cases, lumbar in twenty nine and lumbo-sacral in fifteen. Thirty two free, thirty six hemifused and only one fused H.V. were operated on. The sex ratio was 35 males and 34 females. Associarted malformations were numerous. If the rate of visceral associated malformations is rather the same whatever was the location of the H.V. ( 40% ) the number of associated spine malformations decrease from cranial to caudal ( 60% for thoraco-lumbar H.V. versus 13 % for lumbo-sacral H.V.) The mean age at surgery was 3Y 3M ( 1Y- 9Y) with a mean F.U. of 5Y ( 6M-18Y) for the 25 thoraco-lumbar H.V., respectively 3Y3M ( 1Y- 8Y3M) for the mean age at surgery and 5Y ( 1M-17Y5M) for the average F.U.for the 29 lumbar H.V. and 5Y1M (1M-10Y4M) for surgery and 7Y (1M-18Y3M) for F.U. for the remaining 15 lumbo-sacral H.V. Results: 8 complications were encountered: 4 hardware failures, 1 sepsis, 1 transient paresthesia of the tibial nerve, 1 partial loss of power in the tibialis anterior and 1 valgus deformity following fibular bone grafting. For the 25 thoraco-lumbar H.V. the average scoliosis Cobb angle pre operatively was 38° ( 18°/ 75°) and at F.U. 24° ( 0°/ 76°) . The mean kyphosis Cobb angle was 24° ( -20°/ 54°) pre operatively and 25° (-16°/60°) at F.U. For the 29 lumbar H.V. the mean scoliosis Cobb angle was 35° (16°/58°) pre operatively and 10° (0°/38°) at F.U.The average kyphosis Cobb angle was -2°( -45°/20°) pre operatively and -6° (-42°/22°) at F.U. For the remaining 15 lumbo-sacral H.V. the average scoliosis Cobb angle was 30° (18°/40°) pre operatively and 13° (2°/32°) at F.U. The mean kyphosis Cobb angle was -22°(-54°/0°) pre operatively and -25°(-64°/-8°) at F.U. H.V. excision is in our opinion the best procedure to treat thoraco-lumbar,lumbar and lumbo-sacral H.V. as far as there is evidence of curve progression. The appropriate age to perform this kind of surgery is before three years of age.
We wished to see if Orthopaedic Surgeons are using the current evidence with regard to the use of drains in knee arthroplasty. A questionnaire was faxed to UK members of BASK. We had a 71. 7% response rate (160 responses out of 223). For primary TKR, 89. 5% always use a drain. 42. 1% removed their drains at between 24 and 48 hours. The commonest reason for using drains was to prevent haematoma or haemarthrosis development. The study suggests that the majority of BASK members do not practice evidence based medicine with regard to the use of knee drains.
Primary TKR: Always 136(89.5%); Sometimes 13(8.5%), Never 3(2.0%). Revision TKR: Always 141(94.6%); Sometimes 3 (2.0%); Never 5(3.4%); Not applicable 3. Unicompartmental: Always 66(57.9%); Sometimes 28(24.6%); Never 20(17.5%); Not applicable 3.1. Hours drain removed at: <
24 hours 77(50.7%); 24–48 hours 64(42.1%); >
48 hours 4(2.6%); No answer 7(4.6%). Rationale for drain use: Prevent wound haematoma/haemarthrosis 74; personal reasons 27; to allow retransfusion 20; evidence based 12; despite evidence 5. 29.6% of the responders are currently using cell salvage drains, and a further 7.9% are keen to start using cell salvage drains when the circumstances in their hospitals change to allow them to do so.