Advertisement for orthosearch.org.uk
Results 51 - 100 of 119
Results per page:
Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 114 - 114
1 Mar 2006
Bartlett W Gooding C Amin A Skinner J Carrington R Flanagan A Briggs T Bentley G
Full Access

Background: Autologous chondrocyte implantation (ACI) was introduced over 15 years ago as a treatment for full-thickness chondral defects in the knee. Current understanding of ACI graft morphology and maturation in humans is limited. The aims of this study were determine the incidence of hyaline-like repair following ACI, and to clarify the relationship between repair morphology and clinical outcome.

Methods: A retrospective review of 194 ACI graft biopsies from 180 patients, and their clinical outcome was conducted. 154 Biopsies were performed 1 year after implantation and 40 biopsies were performed at 2 years. Three techniques of ACI implantation were used; Collagen covered ACI (ACI-C), periosteum covered ACI (ACI-P) and Matrix-Induced ACI (MACI).

Results: At 1 year, hyaline repair tissue was found in 48 (53%) ACI-C grafts, 7 (44%) ACI-P grafts, and 12 (36%) MACI grafts. The frequency of hyaline tissue found in biopsies performed at 2 years (84%) was significantly higher than those performed at 1 year (48.6%), p=0.0001, suggesting that grafts continue to remodel after the first year post implantation.

Clinical outcomes during the first two postoperative years did not vary according to repair morphology type, though hyaline repair was associated with better clinical outcomes beyond 2 years; At 1 year, good to excellent clinical scores were observed in 29 (78.4%) patients with hyaline-like repair, 23 (76.7%) patients with fibrohyaline repair, and 54 (74.0%) patients with fibrocartilage repair. By years 3 and 4 post-implantation, clinical scores further improved in patients with hyaline-like repair yet declined in those with fibrocartilage and fibrohyaline. The difference was significant at 3 years though not at 4 due to the small number of cases.

Conclusions: Achieving hyaline-like repair is critical to the longevity of cartilage repair. The finding of hyaline-like cartilage or fibrohyaline cartilage in 31 of 37 biopsies (84%) performed after 2 years is therefore encouraging and supports further use of the ACI technique.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 114 - 114
1 Mar 2006
Bartlett W Gooding C Skinner J Carrington R Flanagan A Briggs T Bentley G
Full Access

Background: Autologous Chondrocyte Implantation (ACI) is widely used as a treatment for symptomatic chondral and osteochondral defects of the knee. Variations of the original periosteum cover technique include the use of porcine-derived type I/III collagen as a cover (ACI-C), and the use of a collagen bilayer seeded with chondrocytes (MACI).

Aim: To determine whether differences in clinical, arthroscopic and histological outcomes at 1 year exist between ACI-C and MACI techniques.

Methods: We have performed a prospective randomised comparison of ACI-C versus MACI for the treatment of symptomatic chondral defects of the knee on 91 patients of whom 44 received ACI-C and 47 received MACI grafts.

Results: Both treatments resulted in improvements of clinical scores after 1 year. Mean modified Cincinnati knee scores increased by 17.5 in the ACI-C group and 19.6 in the MACI group (p> 0.05). Arthroscopic assessments performed after 1 year demonstrated good to excellent ICRS graft repair scores in 79% of ACI-C grafts and 67% of MACI grafts. Hyaline-like or hyaline-like cartilage with fibrocartilage was found in the biopsies of 43% of ACI-C grafts and 36% of MACI grafts after 1 year. The rate of graft hypertrophy was 9% in the ACI-C group and 6% in the MACI group. The frequency of re-operation was 9% in each group.

Conclusions: We conclude that clinical, arthroscopic and histological outcomes are comparable for both ACI-C and MACI techniques. While the MACI technique is technically attractive, further long-term studies are required before widespread adoption of this new technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 203 - 205
1 Feb 2006
Krishnan SP Skinner JA Carrington RWJ Flanagan AM Briggs TWR Bentley G

We prospectively studied the clinical, arthroscopic and histological results of collagen-covered autologous chondrocyte implantation (ACI-C) in patients with symptomatic osteochondritis dissecans of the knee. The study included 37 patients who were evaluated at a mean follow-up of 4.08 years.

Clinical results showed a mean improvement in the modified Cincinnati score from 46.1 to 68.4. Excellent and good clinical results were seen in 82.1% of those with juvenile-onset osteochondritis dissecans but in only 44.4% of those with adult-onset disease.

Arthroscopy at one year revealed International Cartilage Repair Society grades of 1 or 2 in 21 of 24 patients (87.5%). Of 23 biopsies, 11 (47.8%) showed either a hyaline-like or a mixture of hyaline-like and fibrocartilage, 12 (52.2%) showed fibrocartilage.

The age at the time of ACI-C determined the clinical outcome for juvenile-onset disease (p = 0.05), whereas the size of the defect was the major determinant of outcome in adult-onset disease (p = 0.01).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 61 - 64
1 Jan 2006
Krishnan SP Skinner JA Bartlett W Carrington RWJ Flanagan AM Briggs TWR Bentley G

We investigated the prognostic indicators for collagen-covered autologous chondrocyte implantation (ACI-C) performed for symptomatic osteochondral defects of the knee.

We analysed prospectively 199 patients for up to four years after surgery using the modified Cincinnati score. Arthroscopic assessment and biopsy of the neocartilage was also performed whenever possible. The favourable factors for ACI-C include younger patients with higher pre-operative modified Cincinnati scores, a less than two-year history of symptoms, a single defect, a defect on the trochlea or lateral femoral condyle and patients with fewer than two previous procedures on the index knee. Revision ACI-C in patients with previous ACI and mosaicplasties which had failed produced significantly inferior clinical results. Gender (p = 0.20) and the size of the defect (p = 0.97) did not significantly influence the outcome.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 322 - 322
1 Sep 2005
Gooding C Bentley G Carrington R Briggs T Skinner J
Full Access

Introduction and Aims: ACI (autologous chondrocyte implantation) using a periosteum cover was developed by Peterson et al. Recently, the technique has been developed using a Type I/Type III collagen membrane (Chondro-Gide). A second technique MACI (matrix-induced autologous chondrocyte implantation) has evolved using a membrane with chondrocytes seeded onto its surface. Aim is to review the one and two-year results of the first 159 patients at a single regional centre.

Method: The two-stage procedure was performed with a standardised, progressive rehabilitation program. Patients were assessed clinically at three, six, nine, 12 and 24 months (pain score, Modified Cincinnati, Bentley), and arthroscopically at 12 and 24 months.

Results: 159 patients have been assessed at one year and 101 patients at two years. Of those patients reviewed at one year, 110 patients had the ACI repair with Chondro-Gide, 31 patients had the ACI repair with periosteum and 18 patients had the MACI repair. Sixty-nine percent had good or excellent results at one year and 60% at two years.

These figures represent the early results of this study performed at this unit.

Conclusion: We propose that the ACI technique is valuable for selected patients with Chondral and osteochondral defects of the knee even with large and multiple defects in the articular cartilage.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 344 - 345
1 Sep 2005
Beard D Bentley G Carrington R Briggs T Skinner J
Full Access

Introduction and Aims: Uni-compartmental knee arthroplasty (UKA) is appropriate for one in three osteoarthritic knees requiring replacement. An accelerated protocol enables patients undergoing UKA to be discharged within 24 hours of surgery. Before such an approach is universally accepted it must be safe, effective and economically viable. A study was performed to compare the new accelerated protocol with current standard care in a state healthcare system.

Method: A single blind RCT design was used. Patients eligible for UKA were screened for NSAID tolerance, social circumstances and geographical location before allocation to either an accelerated recovery group (Group A) or a standard non-accelerated group (Group S). The accelerated protocol included dedicated pain management and discharge support. Primary outcome was the Oxford Knee Assessment at six months post-operation, compared using independent t tests. Pain, range of movement and incidence of complications were also recorded by assessors blind to group allocation. Cost effectiveness was calculated in quality life adjusted years (QLAY) using the Euroqual instrument. The study power was sufficient to avoid type 2 errors. The study was supported by a NHS Regional R& D grant.

Results: Forty-one patients (21 group A, 20 group S) were included. Groups had comparable age and patient profiles. Average discharge time was 37 hours (1.5 days) for group A and 114 hours (4.3 days) for group S. Pain on hospital discharge was similar for both groups. No significant difference was found between groups for pain or range of movement at any time, although patients in group S regained pre-operative flexion faster than group A. One major complication occurred in each group; one infection (group S) and one manipulation for poor movement (group A). The cost per QLAY for the new protocol was 59% of the standard care.

Conclusion: The new protocol allows for safe accelerated discharge from hospital after UKA. The approach is cost-effective and should help to increase the throughput of patients who require knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1143 - 1149
1 Aug 2005
Akmal M Singh A Anand A Kesani A Aslam N Goodship A Bentley G

The purpose of this study was to examine the effects of hyaluronic acid supplementation on chondrocyte metabolism in vitro. The clinical benefits of intra-articular hyaluronic acid injections are thought to occur through improved joint lubrication. Recent findings have shown that exogenous hyaluronic acid is incorporated into articular cartilage where it may have a direct biological effect on chondrocytes through CD44 receptors.

Bovine articular chondrocytes were isolated and seeded into alginate constructs. These were cultured in medium containing hyaluronic acid at varying concentrations. Samples were assayed for biochemical and histological changes.

There was a dose-dependent response to the exposure of hyaluronic acid to bovine articular chondrocytes in vitro. Low concentrations of hyaluronic acid (0.1 mg/mL and 1 mg/mL) significantly increase DNA, sulphated glycosaminoglycan and hydroxyproline synthesis. Immunohistology confirmed the maintenance of cell phenotype with increased matrix deposition of chondroitin-6-sulphate and collagen type II. These findings confirm a stimulatory effect of hyaluronic acid on chondrocyte metabolism.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 640 - 645
1 May 2005
Bartlett W Skinner JA Gooding CR Carrington RWJ Flanagan AM Briggs TWR Bentley G

Autologous chondrocyte implantation (ACI) is used widely as a treatment for symptomatic chondral and osteochondral defects of the knee. Variations of the original periosteum-cover technique include the use of porcine-derived type I/type III collagen as a cover (ACI-C) and matrix-induced autologous chondrocyte implantation (MACI) using a collagen bilayer seeded with chondrocytes. We have performed a prospective, randomised comparison of ACI-C and MACI for the treatment of symptomatic chondral defects of the knee in 91 patients, of whom 44 received ACI-C and 47 MACI grafts.

Both treatments resulted in improvement of the clinical score after one year. The mean modified Cincinnati knee score increased by 17.6 in the ACI-C group and 19.6 in the MACI group (p = 0.32). Arthroscopic assessments performed after one year showed a good to excellent International Cartilage Repair Society score in 79.2% of ACI-C and 66.6% of MACI grafts. Hyaline-like cartilage or hyaline-like cartilage with fibrocartilage was found in the biopsies of 43.9% of the ACI-C and 36.4% of the MACI grafts after one year. The rate of hypertrophy of the graft was 9% (4 of 44) in the ACI-C group and 6% (3 of 47) in the MACI group. The frequency of re-operation was 9% in each group.

We conclude that the clinical, arthroscopic and histological outcomes are comparable for both ACI-C and MACI. While MACI is technically attractive, further long-term studies are required before the technique is widely adopted.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 330 - 332
1 Mar 2005
Bartlett W Gooding CR Carrington RWJ Skinner JA Briggs TWR Bentley G

Autologous chondrocyte implantation (ACI) is a technique used for the treatment of symptomatic osteochondral defects of the knee. A variation of the original periosteum membrane technique is the matrix-induced autologous chondrocyte implantation (MACI) technique. The MACI membrane consists of a porcine type-I/III collagen bilayer seeded with chondrocytes. Osteochondral defects deeper than 8 to 10 mm usually require bone grafting either before or at the time of transplantation of cartilage. We have used a variation of Peterson’s ACI-periosteum sandwich technique using two MACI membranes with bone graft which avoids periosteal harvesting. The procedure is suture-free and requires less operating time and surgical exposure. We performed this MACI-sandwich technique on eight patients, five of whom were assessed at six months and one year post-operatively using the modified Cincinnati knee, the Stanmore functional rating and the visual analogue pain scores.

All patients improved within six months with further improvement at one year. The clinical outcome was good or excellent in four after six months and one year. No significant graft-associated complications were observed. Our early results of the MACI-sandwich technique are encouraging although larger medium-term studies are required before there is widespread adoption of the technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 128 - 134
1 Jan 2005
Goldberg AJ Lee DA Bader DL Bentley G

An increasing number of patients are treated by autologous chondrocyte implantation (ACI). This study tests the hypothesis that culture within a defined chondrogenic medium containing TGF-β enhances the reexpression of a chondrocytic phenotype and the subsequent production of cartilaginous extracellular matrix by human chondrocytes used in ACI. Chondrocytes surplus to clinical requirements for ACI from 24 patients were pelleted and cultured in either DMEM (Dulbecco’s modified eagles medium)/ITS+Premix/TGF-β1 or DMEM/10%FCS (fetal calf serum) and were subsequently analysed biochemically and morphologically.

Pellets cultured in DMEM/ITS+/TGF-β1 stained positively for type-II collagen, while those maintained in DMEM/10%FCS expressed type-I collagen. The pellets cultured in DMEM/ITS+/TGF-β1 were larger and contained significantly greater amounts of DNA and glycosaminoglycans. This study suggests that the use of a defined medium containing TGF-β is necessary to induce the re-expression of a differentiated chondrocytic phenotype and the subsequent stimulation of glycosaminoglycan and type-II collagen production by human monolayer expanded chondrocytes.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 625 - 625
1 Jul 2004
Benson M Bentley G


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 619 - 620
1 May 2004
BENTLEY G


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 263 - 263
1 Mar 2004
Carrington R Skinner J Lewis A Bentley G
Full Access

Aims: The objective of this study was to clinically assess the outcome of CADCAM femoral components in the revision hip replacement. Methods: Between 1991 and 2000, 125 revision total hip replacements using CAD-CAM femoral components were performed. Clinical assessment was performed using the Harris Hip score, by direct patient consultation, and telephone or postal questionnaire. Survivorship was defined as the requirement for revision. Results: The patients were reviewed at a mean of 5.2 yrs (1 to 10)

The mean Harris hip score increased from 44 points (range, 27 to 71 points) preoperatively to 71 points (range, 21 to 98 points) at the time of the most recent follow-up. 9 patients required subsequent revision; 4 for aseptic loosening, 1 for septic loosening and 4 for fracture of the femoral component. Conclusions: CAD-CAM technology provides a viable alternative to the challenge of revision hip surgery, with results comparable to other cementless techniques.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 223 - 230
1 Mar 2003
Bentley G Biant LC Carrington RWJ Akmal M Goldberg A Williams AM Skinner JA Pringle J

Autologous chondrocyte implantation (ACI) and mosaicplasty are both claimed to be successful for the repair of defects of the articular cartilage of the knee but there has been no comparative study of the two methods. A total of 100 patients with a mean age of 31.3 years (16 to 49) and with a symptomatic lesion of the articular cartilage in the knee which was suitable for cartilage repair was randomised to undergo either ACI or mosaicplasty; 58 patients had ACI and 42 mosaicplasty. Most lesions were post-traumatic and the mean size of the defect was 4.66 cm2. The mean duration of symptoms was 7.2 years and the mean number of previous operations, excluding arthroscopy, was 1.5. The mean follow-up was 19 months (12 to 26).

Functional assessment using the modified Cincinatti and Stanmore scores and objective clinical assessment showed that 88% had excellent or good results after ACI compared with 69% after mosaicplasty. Arthroscopy at one year demonstrated excellent or good repairs in 82% after ACI and in 34% after mosaicplasty. All five patellar mosaicplasties failed.

Our prospective, randomised, clinical trial has shown significant superiority of ACI over mosaicplasty for the repair of articular defects in the knee. The results for ACI are comparable with those in other studies, but those for mosaicplasty suggest that its continued use is of dubious value.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 107 - 107
1 Feb 2003
Biant LC Bentley G
Full Access

Autologous Chondrocyte Implantation (ACI) is a technique for repair of isolated symptomatic articular cartilage defects in the young adult knee. The knee is arthroscopically assessed and a sample of cartilage is harvested from the margin of the joint, this is digested and the liberated chondrocytes expanded in culture. At subsequent arthrotomy, the articular cartilage lesion is debrided and the cells injected behind a sutured flap. A concern regarding ACI is the iatrogenic insult to non-injured healthy cartilage adjacent to that harvested for culture.

Damaged cartilage around the lesion is routinely debrided and discarded at the second stage operation. The purpose of this study was to determine whether this damaged debrided cartilage could yield an adequate number of equivalent chondrocytes for ACL.

Cells from 11 patients were analysed. The debrided “waste” from around the lesion was collected, enzymatically digested and the liberated chondrocytes cultured in monolayer.

The cells were recovered and placed in a 3D-pellet culture in a defined medium.

Chondrocytes obtained from the routine harvest of healthy cartilage were placed in a similar culture system. The two groups were compared using DNA and GAG assays, histological and immunohistochemical techniques.

Chondrocytes obtained from the debrided cartilage lesion were equivalent to those obtained from the harvested healthy cartilage. Sufficient cell numbers for implantation were achieved for all patients, however cells cultured from the debrided defect in patients who had a large degenerate lesion required significantly longer in culture to attain the required number of cells.

For many patients undergoing ACI, the potential iatrogenic insult to the joint cartilage of the harvesting procedure could be avoided by harvesting the damaged tissue from around the defect itself.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 105 - 105
1 Feb 2003
Bentley G Biant LC Hunter M Nicolau M Carrington R Williams A Goldberg A Akmal M Pringle J
Full Access

Mosaicplasty1 and Autologous Chondrocyte Implantation2 (ACI) are both modern cartilage repair techniques used to repair symptomatic articular cartilage defects in the knee, based on small osteochondral grafts and cultured chondrocytes respectively. The aim is the restoration of articular cartilage, but until now there is no data comparing the two methods.

100 consecutive patients aged 15–45 with a symptomatic articular cartilage lesion in the knee suitable for cartilage repair were randomised at arthroscopic assessment to undergo either mosaicplasty or ACI. 42 patients underwent mosaicplasty, 58 had ACI. Mean age at time of surgery was 31 years and the average defect size 4. 66 cm2.

46% of the defects were post-traumatic, 19% had osteochondritis dissecans, 14% had chondromalacia patella and 16% had lesions of unknown aetiology. 53% had a medial femoral condyle lesion, 25% patella, 18% lateral femoral condyle, 3% trochlea and there was one defect of the lateral tibial plateau.

The mean duration of symptoms was 7. 2 years and the average number of previous operations (excluding arthroscopies) was 1. 5. Only 6 patients had no prior surgical interventions to the affected knee. The mean follow-up was 1. 7 years.

Patients were evaluated using Modified Cincinnati and Stanmore Functional rating systems, visual analogue scores and clinical assessment. Arthroscopy and biopsy was performed at one year and repair assessed with the International Cartilage Repair Society grading system.

Clinical results at one year showed 70% of mosaic-plasty patients and 87% of ACI patients had a good or excellent result. Arthroscopy at one year demonstrated more complete healing in ACI patients. Eleven (26%) of the mosaicplasty group subsequently failed clinically and arthroscopically, with peak failure at 2 years.

At one year follow-up, both techniques of articular cartilage repair can be useful in selected patients. ACI is preferred for lesions of the patella. Long-term follow-up is needed to assess the durability of articular cartilage repair using these methods, in particular mosaicplasty which showed signs of progressive failure over 2 years.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 106 - 106
1 Feb 2003
Bentley G Hunter M Biant LC Nicolau M Carrington R Williams A Goldberg A Akmal M Pringle J
Full Access

Autologous Chondrocyte Implantation’ (ACI) is a cartilage repair technique that involves implantation of cultured chondrocytes beneath a membrane of autologous periosteum. In this study a porcine biodegradable membrane was also used to assess its effectiveness. The aim is to restore articular cartilage to symptomatic defects, rather than initiating a fibrocartilagenous repair.

We undertook a prospective study of 125 consecutive patients who underwent ACI. Average age at the time of surgery was 30. 9 years (range 14 – 49), 55% of patients were male. The average size of the defect was 4. 35 cm².

44% of defects were attributable to known traumatic incidents, 2 1 % had osteochondritis dessicans, 18% chondromalacia patella, 12% had defects of unknown aetiology and 5% other.

The average duration of symptoms prior to this surgery was 7. 16 years. The mean number of previous operations (excluding arthroscopies) was 1. 6. Only 9 patients had no previous major surgery to the affected knee. 44% had defects of the medial femoral condyle, 31% patella, 20% lateral femoral condyle and 5% had a trochlea lesion. 26% of the defects were covered with periosteum and 74% with a porcine collagen membrane (chondrogide)

Minimum follow-up was six months, 70 patients had minimum follow-up of one year. Mean follow-up 18 months.

Patients were assessed using Modified Cincinnati and Stanmore Functional rating systems, visual analogue scores and clinical evaluation.

Arthroscopy and biopsy was performed at one year and the repair assessed using the International Cartilage Research Society grading system.

At one year follow-up overall 41 % patients had an excellent result, 48% good, 8% fair and 3% poor. For defects of the medial femoral condyle, 88% had a good or excellent result, 85% for the lateral femoral condyle and 80% for the patella.

61 patients were arthroscopically assessed at one year. 50/61 (82%) demonstrated ICRS grade 1 or 2 repair. Healing of the defect occurred with either a periosteum or chondrogide defect cover.

Results at one year suggest that ACI is a successful articular cartilage repair technique in selected patients. Long-term follow-up is required to assess the durability of the repair.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 118 - 118
1 Feb 2003
Biring GS Bentley G
Full Access

The clinical results of carbon matrix support prostheses for treatment of articular cartilage defects of the femoral condyle and patella were assessed in 97 patients (100 prostheses) between 1989–99. Patients were independently reviewed by subjective and objective criteria. Pre-operative and current visual analogue scores for pain (VAPS); Stanmore and modified Cincinnati functional rating scores were obtained. Forty-nine patients had lesions of the patella, forty-four patients of the medial femoral condyle and seven patients of the lateral femoral condyle.

Patella group – subjectively 49% reported they were improved, 8% unchanged and 43% worse. Stanmore score: 6 excellent and 17 good (47%), 5 fair and 21 were poor. The Cincinnati score increased from 26. 5 pre-operatively to 47. 5 currently (p< 0. 001). The mean VAPS decreased from 8. 1 to 5. 0 (p< 0. 001).

Medial femoral condyle group – subjectively 60% reported they were improved, 14% unchanged and 26% worse. Stanmore score: 8 excellent and 16 good (55%), 8 fair and 12 poor. The Cincinnati score increased from 22. 3 pre-operatively to 48. 5 currently (p< 0. 001). The mean VAPS decreased from 8. 6 to 5. 1 (p< 0. 001).

Lateral femoral condyle group – subjectively 42% reported they were improved, 29% unchanged and 29% worse.

Stanmore score: 2 excellent and 1 good (43%), 2 fair and 2 poor. The Cincinnati score increased from 35. 0 pre-operatively to 52. 0 currently (p< 0. 25). The mean VAPS decreased from 6. 5 to 4. 0 (p< 0. 25).

There were no statistical differences in outcome based upon gender, site, pre-operative functional rating score, diagnosis, or any correlation with age or length of follow up, or when comparing excellent/good with fair/ poor subgroups in patellae or femoral condyles in relation to these variables.

This study demonstrated that 49% improved in the patella group, 60% in the medial femoral condyle and 43% in the lateral femoral condyle groups. The use of these prostheses was effective on the medial femoral condyle for periods up to 10 years but the use in the patella and lateral femoral condyle was less successful.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 5 - 5
1 Jan 2003
Singh A Akmal M Enobakhare B Kesani A Goodship A Bentley G
Full Access

The use of intra-articular hyaluronic acid injections for the treatment of early osteoarthritis is in widespread clinical use. Hyaluronate (HA) is a major component of connective tissue1 and is available commercially for the intra-articular injective treatment of osteoarthritis of the knee and periarthritis of the shoulder. Although it is known to improve intra-articular lubrication it is also thought to promote articular cartilage structure and prevent catabolism of matrix proteoglycans in osteoarthritis. Clinical studies have shown beneficial effects lasting for many months after cessation of therapy unlike anti-inflammatory drugs that have relatively short term relieving effects2,3 . Documentation of the true chondroprotective effects of hyaluronic acid (HA) at the cellular level is lacking and therefore this study aimed to identify the effects of HA on chondrocytes cultured in vitro.

Bovine articular chondrocytes were isolated by sequential digestion with pronase and collagenase and seeded in 2% alginate at 1x107 cells/ml. The constructs were cultured for up to 14 days in standard culture medium (DMEM + 20% Fetal calf serum) containing varying concentrations of HA (Sigma), including doses equivalent to those found in vivo. The medium was replaced every 3 days and representative constructs were removed from culture, digested and assayed for DNA, glycosaminoglycans and Collagen. Further constructs were fixed in 4% paraformaldehyde for standard histology and immunolocalisation of collagen types I, II and chondroitin-6-sulphate.

Chondrocytes cultured in the HA system proliferated (increase in DNA) at a faster rate than the controls. There was a 2.2 fold increase in cell concentration at 14 days compared to a 1.2 fold increase in the controls. Total GAG levels at each time point were significantly greater for cells cultured in HA than in controls. Histologically, constructs were characterised by extensive cell cluster formation and intense Safranin-O staining. The newly synthesised matrix also stained positive for type II collagen. By contrast, control constructs exhibited minimal cluster formation, Safranin-O and type II collagen staining.

Cells maintained with HA exhibited a significantly greater rate of proliferation and matrix production. The presence of matrix rich in type II collagen indicates maintenance of chondrocytic phenotype. By contrast, cells cultured without HA did not show these features. These results support the use of intra-articular injections for the treatment of osteoarthritis. The benefits of HA injections may be due to cellular mechanisms as well as mechanical.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 5 - 5
1 Jan 2003
Mannering N Akmal M Enobakhare B Singh A Goodship A Bentley G
Full Access

The use of intra-articular corticosteroid injections for their anti-inflammatory effects is widespread amongst clinicians. Despite their use in both rheumatoid arthritis and osteoarthritis, the effect of these agents on articular chondrocytes is not fully established. Previous reports suggest a detrimental effect on cartilage explants resulting from inhibition of matrix synthesis1. However it has also been suggested that the beneficial effects in vivo may be due to prevention of inflamed synovium causing cartilage degradation2. Our aim was to assess the effect of a commercially available preparation of methylprednisolone (MP), at clinical doses, on articular chondrocytes cultured in vitro.

Bovine articular chondrocytes were isolated by sequential digestion with pronase and collagenase and seeded in 2% alginate at 1x107 cells/ml. The constructs were cultured for up to 15 days in standard culture medium (DMEM + 20% Fetal calf serum) containing varying concentrations of MP, including doses equivalent to those found in vivo. The medium was replaced every 3 days and representative constructs were removed from culture, digested and assayed for DNA and glycosaminoglycans. Further constructs were fixed in 4% paraformaldehyde for standard histology and immunolocalisation of collagen types I, II and chondroitin-6-sulphate.

Chondrocytes cultured in MP containing medium showed a significant abnormality in cell morphology compared to controls at the day 15 time point. Histologically there was evidence of cell necrosis, reduced amounts of extracellular matrix and loss of collagen type II staining. The effects were dose dependant, with significant damage occurring even at clinical doses. Biochemical analysis revealed a reduction in DNA content and an inhibition of glycosaminoglycan and collagen type II synthesis. In contrast, in the controls, there was cell proliferation with a cell doubling time of 14 days, collagen type II containing extracellular matrix synthesis occurred and the chondrocytes maintained their phenotype throughout the culture period.

Methylprednisolone has a significant detrimental effect on cultured articular chondrocytes in vitro. There was significant cell necrosis associated with inhibition of extracellular matrix synthesis. Based on these results, intra-articular corticosteroid injections should be used with extreme caution.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 6 - 6
1 Jan 2003
Kesani A Akmal M Enobakhare B Mannering N Goodship A Bentley G
Full Access

Nicotine is a constituent of tobacco smoke and is present in the body fluids of smokers1,2. Numerous studies have confirmed that smoking is a strong risk factor for back pain3. The most widely accepted explanation for the association is that smoking leads to malnutrition of spinal discs due to carboxyhaemoglobin formation. However, other constituents of smoke, such as nicotine, may also be responsible for intervertebral disc (IVD) degeneration by leading to cell necrosis in both the nucleus pulposus and annulus fibrosis. Despite evidence suggesting the detrimental effect on a variety of tissues, the effect of nicotine on IVD cells has not previously been investigated. This study investigated the influence of nicotine on the metabolism and viability of IVD cells cultured in vitro.

Bovine nucleus pulposus (NP) intervertebral disc cells were isolated by sequential digestion of caudal spinal disc nuclei with pronase and collagenase and seeded in 2% alginate at 5x106 cells/ml. The constructs were cultured for 21 days in standard culture medium (DMEM + 20% Fetal calf serum) containing free base nicotine (Sigma) at concentrations ranging from 25nM and 300nM, which reflected the normal physiological concentrations found in the serum of smokers. The medium was replaced every 3 days and representative constructs were removed from culture, digested and assayed for DNA, glycosaminoglycan (GAG) and hydroxyproline content at time points 3, 7, 14 and 21 days. Further constructs were processed for standard histology and immunolocalisation of collagen types I, II and chondroitin-6-sulphate.

The results were analysed statistically using an ANOVA test followed by a non-parametric Dunnit’s test. NP cells demonstrated a dose dependent response. At 25nM dose of nicotine there was a significant increase (p< 0.05) in DNA content, GAG and collagen synthesis in the constructs. At 100nM, 200nM and 300nM doses, there was a significant dose dependent decrease (p< 0.05) in all of these parameters compared to controls cultured under nicotine free conditions. In addition, adverse morphological changes were observed on histology, which included reduced cell proliferation, disrupted cell architecture, disintegration of cells and extracellular matrix. Immunohistochemistry showed the production of type I collagen rather than type II collagen as in the controls.

Nicotine has an overall detrimental effect on cultured nucleus pulposus disc cells in vitro. There was significant inhibition of cell proliferation and extracellular matrix synthesis. Nicotine in tobacco smoke may therefore play a role in the aetiology of disc degeneration that leads to back pain in smokers.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 2 - 3
1 Jan 2003
Akmal M Kesani A Kakar S Bentley G
Full Access

Deep infection is a devastating complication of total joint arthroplasty. In a significant proportion of cases it remains a diagnostic challenge. Haematological tests are not specific, particularly in chronic cases, and radiological investigations such as bone scan and radiographs are of only limited value. The most common infective organisms are staphylococcus and some streptococcus species. Acidity is a well established occurrence in infective processes and is caused by the direct production of acid by the organism or by enzymatic degradation of tissues 1,2. In wound infections, peritonitis and some other conditions pH is used as an indicator of infection in clinical practice3. The aim was to assess whether fluid biochemistry (pH, pCO2, pO2, Lactate and Glucose) is altered in infected total knee replacements and whether it could be used as a diagnostic test.

Nineteen consecutive patients undergoing either revision total knee replacement (TKR) or arthroscopic synovial biopsy were included in the study. All had had their primary joint replacement within the previous 3 years. All had a painful total knee replacement and some had evidence of loosening of the prosthesis on radiological investigations. The following investigations were performed on each patient, White cell count (WCC), Erythrocyte Sedimentation Rate (ESR), C-Reactive Protein (CRP), interface synovial biopsy for histology and microbiology and a synovial fluid aspiration from the affected joint prior to application of a tourniquet. A blood gas analyser was used to measure pH, pCO2, pO2, Lactate and Glucose in all synovial fluid specimens.

Seven patients were diagnosed as having an infected TKR on clinical and laboratory investigations. The mean synovial fluid biochemistry results were pH = 7.09, pO2= 5.08kPa, pCO2=10.40kPa, Lactate = 5.33 mmol/l, Glucose = 2.30 mmol/l. In the non-infected group the results were pH = 7.23, pO2 = 7.72kPa, pCO2 = 8.41kPa, Lactate = 4.03 mmol/l, Glucose = 3.42 mmol/l. The differences in pH, pCO2/pO2 ratio, and glucose levels were statistically significant (t-Test p < 0.05) between the two groups. Lactate levels were not significantly different. There was no correlation between high WCC’s and synovial fluid biochemistry or laboratory results for infected cases. Using laboratory results as a gold standard and a synovial fluid pH of less than 7.20, the sensitivity was 85% and specificity 77% for diagnosing an infection. Using a combination of the synovial fluid biochemistry results these values were greater.

Synovial fluid biochemistry is significantly altered in infected total knee replacements. pH levels below 7.2, pCO2/pO2 ratio above 2.5 and Glucose levels below 2.5 mmol/l are strong indicators of an infected TKR. Synovial pH assessment may prove to be a quick, cheap and effective method of diagnosing an infected TKR and may also apply to other joints. Further studies using non-problematic TKR’s as controls are required.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 242 - 242
1 Nov 2002
Bentley G Goldberg A Biant L Hunter M Carrington R
Full Access

Many methods have been described over the past 5 years for repair of articular cartilage defects. The best reported results have been from the use of autologous chondrocyte transplantation (ACT)(1) and mosaicplasty.(2) There have, however, been no prospective clinical trials of these two methods. In this trial 70 patients were prospectively randomized to receive either autologous chondrocyte transplantation (37) or mosaicplasty (33) in the knee. 37 patients were female and 33 male. The average age was 32 years (16 – 44). The indications for surgery were persistent pain and mechanical symptoms in the knee with an isolated defect of the articular cartilage. 38 (56%) were post-traumatic, 12 (16%) due to osteochondritis dissecans, 10 (14%) due to previous meniscectomy, and 10 (14%) due to chondromalacia patellae. The size of the defects ranged from 2cm2 to 12cm2 (mean 4.8cm2). There were 35 defects on the medial femoral condyle, 13 on the lateral femoral condyle, 17 on the patella and 5 on the trochlear. 31 patients were undergoing primary surgery and 39 secondary surgery. All were independently reviewed using the Visual Analogue Pain Score, the Cincinatti Pain Score and the Stanmore Score. Patients were arthroscoped at one year with MRI scan and biopsies where possible.

Results: The visual analogue pain score improved overall from a mean of 5.4 (range 3.4 – 7.4) pre-operatively to 3.9 (1.8 – 5.1) at one year review. Similarly the Cincinatti pain score improved from 6.5 pre-operatively to 10.2 post-operatively and the Cincinatti function score improved from 46 to 62 at one year before sport commenced. Overall 71% (49) patients were excellent or good on the clinical scoring scales, 15% (11) were fair, and 14% (10) were poor. The 10 poor results were no different from the main group with regard to age, sex, pain level or site or size of lesion. However, 5 were secondary procedures, 2 had multiple lesions, and 3 had had previous ruptured anterior cruciate ligaments. Arthroscopy and biopsy of 21 lesions so far after one year has shown mature articular cartilage in 2, and immature cartilage in 19. In all cases there was bonding of the repair tissue to the underlying bone. This study is already clarifying the role of ACT and mosaicplasty in the management of cartilage defects in the knee and also the necessity for the use of periosteal covering membrane.


The purpose of this study was to evaluate the influence of trochlear design in total knee replacement with and without patellar resurfacing.

Methods and Results: In 1992 a trial was set up, including all patients undergoing primary PFC (Johnson & Johnson) total knee replacement. Patients were randomised to either patellar resurfacing or retention. The patients were assessed using the American Knee Society rating, a clinical anterior knee pain score and BOA patient satisfaction score. Assessment was performed without knowing whether the patella had been resurfaced.

In July 1998 we began using the PFC Sigma. This incorporates a deeper trochlear groove with a 5° valgus angle.

We compared the results for the two types of prosthesis. In the PFC group there were 474 knees in 390 patients. Follow-up was from 2 to 9 years (mean 5.5 years). The overall prevalence of anterior knee pain) was 25.1% (58 knees) and 5.3% (13 knees) in the non-resurfaced group (n=231) versus the resurfaced group (n=243) respectively. Anterior knee pain became apparent in all cases within 18 months.

In the PFC sigma group there were 67 knees in 62 patients. Follow-up was from 18 months to 3 years (mean 2 years). The incidence of anterior knee pain was 0 in the resurfaced group (n=30) versus 37.8% (14 knees) in the non-resurfaced group (n=37). Knee scores were lower in the non-resurfaced groups for each prosthesis.

Conclusion: The prevalence of anterior knee pain was significantly higher in knees with non-resurfacing of the patella. The asymmetrical, deeper femoral groove improves anterior knee pain with the resurfaced patella but may contribute to it if not resurfaced. We recommend patellar resurfacing in all cases where technically possible.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 125 - 125
1 Jul 2002
Maruthainar N Graham D Surace F Bentley G
Full Access

The issue of preservation or sacrifice of the posterior cruciate ligament in total knee arthroplasty remains unresolved.

We report the results of 200 consecutive total knee arthroplasties performed at our hospital under the direction of the senior author. Pre-operatively, patients were randomly chosen to receive either a Kinemax (posterior cruciate retaining) or a Press-Fit-Condylar (posterior cruciate sacrificing) prosthesis. We implanted 97 Kinemax and 103 Press-Fit-Condylar prostheses which were prospectively followed-up by clinical and radiographic assessment. Review at mean follow-up of 2.7 years showed a satisfactory clinical result in both groups [Surace, et al., 1994].

We present the results of our further review, with maximum follow-up of over nine years (mean: 5.9 years). Revision of the implant has been performed in five knees (three Kinemax and two Press-Fit-Condylar). The polythene spacer had to be replaced in one patient with a Press-Fit-Condylar implant.

Patients were assessed with the Hospital for Special Surgery Knee Score and radiologically assessed with the Knee Society Roentgenographic Evaluation and Scoring System. Pre-operative demographics and disease states of the patients were similar, with an average Hospital for Special Surgery Knee Score of 63. At the latest assessment the average knee score was good (85). Remarkably, the mean knee score for the posterior cruciate sacrifice and the PCL groups remains similar (mean: 85). Radiographic evaluation demonstrated that the prosthetic components of both groups were in comparable alignment. The posterior cruciate ligament retained (Kinemax) patient group showed a mean 5.9 degrees of the valgus angle at the knee. The angle in the posterior cruciate ligament sacrifice (PFC implant) group was 6.2 degrees. Evaluation of the radiolucent depths below the femoral, tibial and any patella component showed a mean total depth of 1.5 mm (pcl retaining) and 1.7 mm (pcl sacrificing).

Our study presents a quantitative perspective of the results of total knee replacement with proven implant systems and performed in a general orthopaedic unit by both consultants and surgeons in training. The Kinemax (Howmedica) and Press-Fit-Condylar (DePuy Johnson and Johnson) implant systems have both previously demonstrated good results and continue to be available with little subsequent modification.

To our knowledge, there have been no other large prospectively randomised studies of posterior cruciate ligament preservation or sacrifice in total knee replacement.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 119 - 119
1 Jul 2002
Davidson A Bentley G
Full Access

We clinically and radiologically reviewed 79 uncemented PFC acetabular components inserted by our unit during a seven-year period, June 1991 to June 1998. Of these, 50 (63.3%) were primary and 29 (26.7%) were revision arthroplasties. The mean follow-up was five years (60 months), with a range of 12 to 95 months. Sixteen (20%) were excluded from the study, leaving 63 (26.7%) for review. Three (4.7%) cases were deemed to have failed (at 63, 69, 79 months), all of which were primary arthroplasties. One of them was found to be loose at revision and the other two cups had 2 mm of periacetabular radiolucency in only one zone, but had no definite evidence of loosening.

The remaining 60 (95.3%) cases showed no radiological evidence of migration of any cups, and no hip had a radiolucent line in all three zones of the acetabulum. Clinical review gave a mean Harris hip score of 96.5. Fifty (79.4%) reported no pain from the hip. One case (1.6%) had undergone recent revision of the stem, at which time the cup was found to be stable. Three (4.7%) reported slight, occasional pain. Another three (4.7%) described mild pain that did not compromise their average activities and was relieved by simple analgesia. Two cases (3.2%) complained of moderate pain that placed some limitations on their activities and required regular analgesia, and one elderly patient who had an ankylosed contralateral hip and ipsilateral sciatic nerve palsy described marked pain (1.6%), and these were considered poor outcomes. In all of these cases the cups were clinically and radiologically stable.

In conclusion, 81% of outcomes were excellent, painfree THRs. A further 4.75% had good and 4.75% fair results. 4.75% had poor outcomes and 4.75% of cases failed. We conclude that the PFC cup merits continued use and follow-up, and together with other uncemented cup designs, may produce benefits in the form of quality and longevity of results in total hip arthroplasty.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 157 - 157
1 Jul 2002
Waters T Bentley G
Full Access

The purpose of this study was to evaluate the role of patellar resurfacing in total knee replacement surgery. We reviewed 48 patients who had undergone bilateral knee replacement with patellar resurfacing on only one side. Follow-up was from 18 months to 9.5 years and the patients were assessed using the Knee Society rating, a clinical anterior knee pain score and BOA patient satisfaction score. Patients were also asked specifically if they had a preference for either knee. Assessment was performed without knowing which patella had been resurfaced.

52.1% of patients favoured the resurfaced knee, 8% the unresurfaced knee and 39.9% had no particular preference. The overall prevalence of anterior knee pain was 8.3% in the resurfaced cases (3 mild, 1 moderate) and 27.1% in the unresurfaced knees (8 mild, 3 moderate, 2 severe). No significant difference was found between knee scores.

This study shows a significantly higher rate of anterior knee pain in unresurfaced patellae and preference for the resurfaced side.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 22 - 28
1 Jan 2001
Bentley G Haddad F Bull TM Seingry D

We have treated 101 patients with scoliosis secondary to muscular dystrophy over a 13-year period; 64 had Duchenne’s muscular dystrophy, 33 spinal muscular atrophy and four congenital muscular dystrophy.

The patients underwent a modified Luque (87) or Harrington-Luque instrumentation (14) combined with a limited Moe fusion in all except 27 cases. A mean of 13 levels was instrumented. The mean preoperative sitting Cobb angle was 84° (10 to 150) and the mean postoperative angle 40° (52% correction). Most patients (96%) were able to discard their braces and there was a high level of patient satisfaction (89.6%).

Less correction was seen for severe curves, and there was a greater recurrence of postoperative pelvic tilt in those patients not instrumented to the sacrum. Although the incidence of minor or temporary complications was high, these occurred chiefly in the early high-risk patients with very severe curves and considerable pre-existing immobility.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1054 - 1058
1 Sep 2000
Khan U Kakar S Akali A Bentley G McGrouther DA

The formation of restrictive adhesions around the musculotendinous unit after injury is one of the most vexing processes faced by the surgeon. In flexor tendons it has been shown that the synovial tissue is the source of aggressive fibroblasts which contribute to this process. Using a rabbit model, we have examined the effects of treating the synovial sheath with the antimetabolite 5-fluorouracil (5-FU) for five minutes. Inflammatory, proliferative and molecular markers were compared in the response of the treated and control tendons to injury. Compared with a control group we found that the proliferative and inflammatory responses were significantly reduced (p < 0.001) in the treated tendons. Not only was there a reduction in the cellular and cytokine response, but there also was a significant (p < 0.001) reduction in the level of activity of the known pro-scarring agent, transforming growth factor beta 1 (TGF-β1). These pilot studies indicate that the formation of restrictive adhesions may be modulated using a simple single-touch technique in the hope of producing a better return of function.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 647 - 653
1 Jul 1999
Li PLS Zamora J Bentley G

We reviewed the outcome of 146 Insall-Burstein II total knee replacements carried out in 121 patients over a period of nearly four years in a general orthopaedic unit. At a mean follow-up of ten years, 94 knees in 78 patients were available for review. Six patients (7 knees) were lost to follow-up and 37 (45 knees) had died.

The clinical outcome using the scoring system of the Hospital for Special Surgery (HSS) was excellent or good in 79% of patients, fair in 14% and poor in 7%. The mean preoperative HSS score was 31, improving to 79 at the latest review. Using the newer rating system of the Knee Society, the mean score at ten years was 87 and the mean functional score 56. The arc of flexion improved from a mean preoperative value of 88° to 100°. The 18 patients who had had a previous high tibial osteotomy were analysed separately and were found to have benefited equally from the operation. Nine prostheses were revised, giving a cumulative survival rate of 92.3% at ten years. Radiological evaluation of 104 radiographs showed radiolucent lines around ten tibial components, none of which required revision. Anterior knee pain was a significant problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 965 - 970
1 Nov 1998
Meister K Cobb A Bentley G

Between 1989 and 1993 we implanted a matrix support prosthesis made of carbon fibre for the treatment of chronic painful articular defects of the patella in 27 patients. The mean period of follow-up was 33 months (11 to 54) with clinical and arthroscopic evaluation of the implant.

Overall, there were four excellent, three good, seven fair and 13 poor results. Nine patients subsequently had a patellectomy for persistent pain at a mean of 27 months after surgery (14 to 47). The mean visual analogue pain scores in those who retained their patella were 7.6 before operation and 5.5 at the time of the latest follow-up. Patient satisfaction for the entire group was 41%.

There appeared to be good incorporation of the prosthesis and a satisfactory ingrowth of fibrocartilage, but the poor results in 48% and low patient satisfaction discourage us from recommending the procedure for lesions of the articular cartilage of the patella. The consistent seeding of the joint with carbon-fibre debris and a histiocytic giant-cell reaction in the synovium are also a cause for concern.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 53 - 57
1 Jan 1997
Noordeen MHH Lee J Gibbons CER Taylor BA Bentley G

We reviewed retrospectively the role of monitoring of somatosensory spinal evoked potentials (SSEP) in 99 patients with neuromuscular scoliosis who had had operative correction with Luque-Galveston rods and sublaminar wiring.

Our findings showed that SSEP monitoring was useful and that a 50% decrease in the amplitude of the trace optimised both sensitivity and specificity. The detection of true-positive results was higher than in cases of idiopathic scoliosis, but the method was less sensitive and specific and there were more false-negative results. In contrast with the findings in idiopathic scoliosis, recovery of the trace was associated with a 50% to 60% risk of neurological impairment.

Only one permanent injury occurred during the use of this technique, and any temporary impairment resolved within two months.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 546 - 549
1 Jul 1996
Haddad FS Cobb AG Bentley G Levell NJ Dowd PM

Aseptic loosening is seen in a significant proportion of cemented total hip replacements (THR). In a small subgroup of patients who suffer early loosening polyethylene debris is unlikely to be responsible. We recently reported one case of allergic contact dermatitis to N,N-dimethylparatoluidine (DMT), an accelerator used in bone cement. We have therefore investigated this using skin-patch tests to a variety of substances including metals, polyethylene and the separated individual components of Simplex cement.

We studied 70 patients, 15 with aseptic loosening less than two years after THR, 25 with satisfactory long-term cemented fixation, five with infected loosening of cemented THRs and 25 awaiting hip arthroplasty. We found seven positive reactions to DMT, all of them in patients with the rapid onset of aseptic loosening.

Allergy to DMT is recognised in the dental profession in respect of the ‘denture sore mouth’ syndrome, and could also be an occupational hazard since some industrial glues contain DMT. Our results suggest the need for awareness of possible previous dental or occupational exposure to the constituents of bone cement. We recommend the use of skin-patch testing in high-risk cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 178 - 184
1 Mar 1996
Marston RA Cobb AG Bentley G

From 1982 to 1987, we randomised prospectively 413 patients requiring primary total hip replacements to receive either a Stanmore or Charnley prosthesis. They were reviewed by an independent observer in an attempt to correlate a number of factors including femoral head size with longevity. There were 213 Stanmore hips and 200 Charnley prostheses. At five to ten years (mean 6.5) 76 patients had died and 16 arthroplasties had required revision. Seven were radiologically loose in asymptomatic patients. There was only one case of deep infection.

We found no difference statistically in the clinical outcome or in the revision rate of 4% in the two types of prosthesis. The revision rate was greater for trainees than for senior operating surgeons, and there were recognisable technical errors in seven of the nine Stanmore, and four of the seven Charnley replacements which required revision. Retrospective radiological analysis of a random subset of 51 Charnley and 57 Stanmore femoral components showed no difference in femoral subsidence, but in 14 patients who had had bilateral replacements with one femoral component of each type, there was greater early subsidence of the Stanmore prosthesis.

Our results confirm that conventional cemented total hip replacements give acceptable results in a general teaching unit, and we found no evidence of any effect of the size of the femoral head on wear or loosening at five to ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 705 - 714
1 Sep 1995
Walker P Mai S Cobb A Bentley G Hua J

We report the theoretical basis of a method to measure axial migration of femoral components of total hip replacements (THR). The use of the top of the greater trochanter and a lateral point on the collar of the stem, allowing for variations of up to 10 degrees rotation of the femur in any direction between successive radiographs, gave a maximum error of 0.37 mm. At a more realistic 5 degrees rotational variation, the error was only 0.13 mm. These data were confirmed in an experimental study using digitisation of points and special software. We also showed that the centre of the femoral head, the stem tip, and the lesser trochanter provided less accurate landmarks. In a second study we digitised a series of radiographs of 51 Charnley and 57 Stanmore THRs; the mean migration rates were found to be identical. We then studied 46 successful stems with a minimum follow-up of eight years and 46 stems which had failed by aseptic loosening at different times. At two years, the successful stems had migrated by a mean of 1.45 +/- 0.68 mm, but the failed cases had a mean migration of 4.32 +/- 2.58 mm (p < 0.0001). Of the successful cases 76% had migrated less than 2 mm, while in the failed group 84% had migrated more than 2 mm. For any particular case migration of more than 2.6 mm at two years had only a 5% chance of continuing success and would therefore merit special follow-up. Only 24% of the eventually successful stems showed migration at the stem-cement interface, but this had happened in every failed stem. We conclude that it would be possible to evaluate a new cemented design of femoral stem over a two-year period by the use of our method and to compare its performance against the reported known standard of the Charnley and Stanmore designs.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 557 - 561
1 Jul 1995
Harper G Bull T Cobb A Bentley G

We report a high rate of failure of the Ring polyethylene cementless cup caused largely by granulomatous osteolysis. We have reviewed 126 prostheses inserted from 1986 to 1992 at from 11 to 90 months after surgery. There was radiological evidence of osteolytic granulomas adjacent to the external surface of the cup in 32%, appearing on average at three years from operation. In a subgroup of 59 prostheses followed for at least four years the incidence of such changes was 54%. A total of 27 cups (22%) have required revision, 21 for granulomatous loosening at an average follow-up of five years. In the retrieved prostheses there was obvious polyethylene abrasion and histological examination confirmed the presence of polyethylene wear debris. We found no significant correlation of osteolysis with cup size, although smaller cups were predominant among those having revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 384 - 386
1 May 1995
Zaidi S Cobb A Bentley G

We report a case in which the popliteal artery was divided during upper tibial osteotomy performed with the knee in 90 degrees of flexion. This position is believed to allow it to fall safely back from the tibia, but we could find no published confirmation. We used duplex ultrasonography in ten healthy volunteers to measure the distance from the popliteal artery to the posterior surface of the tibia at various degrees of flexion of the knee. Our results showed that in 12 of 20 knees the popliteal artery was closer to the tibia in 90 degrees of knee flexion than in full extension. Surgeons performing upper tibial osteotomy should be aware that flexing the knee does not protect the popliteal artery from injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 329 - 330
1 Mar 1995
Haddad F Levell N Dowd P Cobb A Bentley G


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 485 - 487
1 May 1994
Lennox I Cobb A Knowles J Bentley G

We describe 83 knees (69 patients) which had had patellectomy for anterior knee pain (52), patellofemoral osteoarthritis (25) or comminuted fractures (6) between 1942 and 1978. The patients were questioned about their symptoms and the function of the operated knee 14 to 50 years after operation. In the group with anterior knee pain, 76% achieved good results and were satisfied with the operation. Only 54% of the osteoarthritis group had satisfactory relief of pain and most had progressive deterioration of function. Sixteen patients who had had unilateral patellectomy were assessed by dynamometry, ultrasound and radiography. The average quadriceps muscle power was 60% of that on the normal side although two patients had stronger muscles in their operated than in their unoperated legs.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 476 - 477
1 May 1992
Bentley G


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 795 - 801
1 Sep 1991
Jeffery A Blunn G Archer C Bentley G

The three-dimensional architecture of bovine articular cartilage collagen and its relationship to split lines has been studied with scanning electron microscopy. In the middle and superficial zones, collagen was organised in a layered or leaf-like manner. The orientation was vertical in the intermediate zone, curving to become horizontal and parallel to the articular surface in the superficial zone. Each leaf consisted of a fine network of collagen fibrils. Adjacent leaves merged or were closely linked by bridging fibrils and were arranged according to the split-line pattern. The surface layer (lamina splendens) was morphologically distinct. Although ordered, the overall collagen structure was different in each plane (anisotropic) a property described in previous morphological and biophysical studies. As all components of the articular cartilage matrix interact closely, the three-dimensional organisation of collagen is important when considering cartilage function and the processes of cartilage growth, injury and repair.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 53 - 56
1 Jan 1991
Barrett D Cobb A Bentley G

We measured joint position sense in the knee by a new method which tests the proprioceptive contribution of the joint capsule and ligaments. The leg was supported on a splint, and held in several positions of flexion. The subjects' perception of the position was recorded on a visual analogue model and compared with the actual angle of flexion. Eighty-one normal and 45 osteoarthritic knees were examined, as were 10 knees with semi-constrained and 11 with hinged joint replacements. All were assessed with and without an elastic bandage around the knee. There was a steady decline in joint position sense with age in subjects with normal knees. Those with osteoarthritic knees had impaired joint position sense at all ages (p less than 0.001). Knee replacement improved the joint position sense slightly (p less than 0.02); semi-constrained replacement had a greater effect than hinged replacement. The effect of an elastic bandage in subjects with poor position sense was dramatic, improving accuracy by 40% (p less than 0.001). It is proposed that reduced proprioception in elderly and osteoarthritic subjects may be responsible for initiation or advancement of degeneration of the knee.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 57 - 64
1 Jan 1991
Shahgaldi B Amis A Heatley F McDowell J Bentley G

We report the experimental use of three different biological implants to restore articular surface defects: glutaraldehyde-fixed bovine meniscal xenograft, glutaraldehyde-fixed bovine costal cartilage xenograft, and viable osteochondral allografts. The grafts were implanted in the knees of 19 goats who were allowed free-field activity and were studied for up to one year. The natural articular surfaces of meniscal fibrocartilage provided excellent articular surfaces at all times. Equally good articular surfaces were restored by host tissue growth covering costal cartilage grafts at six months, but by 12 months this surface had degenerated. The majority of the allografts survived and integrated with the host at six months, but many showed signs of failure at 12 months. Only three out of seven ungrafted defects healed completely at six months and the healed surfaces were degenerating at 12 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 634 - 638
1 Jul 1990
Volpin G Dowd G Stein H Bentley G

We reviewed 31 of 33 consecutive patients with intra-articular fractures of the knee at 6 to 22 years (average 14). Of these, 77% had excellent or good results; the others had various degrees of degenerative osteoarthritis. There was no significant difference between the results after surgical or conservative treatment. Secondary degeneration was not related to cause or type of fracture, but its incidence increased with the patient's age at the time of injury, though not with the length of follow-up. Early mobilisation appeared to be beneficial in preventing later degenerative changes.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 607 - 610
1 Aug 1988
Willett K Simmons C Bentley G

A prospective study of 120 consecutive total hip replacements showed that deep suction drains produced maximal drainage volumes in the first 24 hours. Their continued presence resulted in minimal further drainage, did not reduce the likelihood of haematoma formation and led in some cases to the spread of skin organisms into the wound.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 729 - 733
1 Nov 1986
Greenough C Dimmock S Edwards D Ransford A Bentley G

Computerised tomography of the lumbar spine was performed on 22 patients with clinical evidence of prolapse of an intervertebral disc and normal or equivocal radiculograms. Of 11 patients with positive scans who had an operation the presence of pathology was confirmed in 10. Although CT scanning is always helpful in diagnosing disc disorders, where facilities are scarce (as in Great Britain) it is best employed in patients with negative or non-contributory radiculography.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 629 - 634
1 Aug 1986
Volpin G Rees J Ali S Bentley G

Experimentally produced fractures in long bones studied by light and electron microscopic histochemistry were found to heal by a process of enchondral calcification. There was intense proliferation in the cells of the cambium layer of the periosteum, with differentiation to chondroblasts and osteoblasts, suggesting that this layer was the primary tissue responsible for development of the callus. Cytoplasmic processes of the hypertrophic chondrocytes appeared to bud and produce matrix vesicles. Alkaline phosphatase activity was detected along the plasma membrane of the hypertrophic chondrocytes and around the matrix vesicles, before any signs of mineral deposition. Calcification took place by deposition of hydroxyapatite crystals in and around these matrix vesicles which frequently showed alkaline phosphatase activity. It is suggested that there is a close functional association between alkaline phosphatase activity and calcification in the process of fracture healing, which is another type of enchondral calcification mediated by matrix vesicles.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 297 - 300
1 Mar 1986
Dowd G Bentley G

Minor degrees of malalignment of the patella and anatomical abnormalities including a flattened sulcus angle and an increased ratio between patellar tendon length and patellar length (PT:P) have been suggested as predisposing factors in the causation of chondromalacia patellae, as well as patellar instability. In order to confirm or refute this hypothesis a prospective study has been performed comparing the congruence and sulcus angles and the PT:P ratio in a group of 35 patients with chondromalacia confirmed by arthroscopy and a group of 33 patients with instability, with those of a group of 50 knees in normal volunteers. While there was a statistically significant correlation between an increased sulcus and congruence angle and a high-riding patella in patients with instability, no correlation could be identified in patients with idiopathic chondromalacia.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 29 - 35
1 Jan 1986
Aston J Bentley G

Allografts of intact cartilage, isolated chondrocytes and cultured chondrocytes taken from the epiphysial growth-plate and from the articular surface of immature rabbits were inserted into full thickness defects in the tibial articular surface of 160 mature rabbits. In the contralateral knees, which were used as controls, similar defects were made but no grafts were inserted. Grafts were followed up for periods of up to one year after transplantation. Both intact articular and intact growth-plate grafts produced significantly better repair than that seen in control ungrafted defects in normal joints (P less than 0.01 and P less than 0.05 respectively) and in arthritic joints (P less than 0.01). Cultured chondrocytes cut to a precise fit also produced significantly better repair than ungrafted defects in arthritic joints (P less than 0.05).


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 769 - 774
1 Nov 1985
Bentley G

Full thickness samples of articular cartilage were removed from areas of chondromalacia on the medial and "odd" facets of the patellae of 21 adults and examined by histology, autoradiography and electron microscopy. Surface fibrillation, loss of superficial matrix staining and reduced 35SO4 labelling was seen, with little change in the deep zone. Ten cases showed "fibrous metaplasia" of the superficial cartilage with definite evidence of cell division and apparent smoothing of the surface. Scattered chondrocyte replication appeared to occur in the surrounding intact cartilage. The findings suggest that early lesions in chondromalacia patellae may heal either by cartilage or fibrous metaplasia and that this may account for the resolution of clinical symptoms.