header advert
Results 41 - 60 of 4366
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 100 - 100
2 Jan 2024
Jahr H
Full Access

Degeneration of the intervertebral disc (IVD), and subsequent low back pain, is an almost inevitable cause of disability. The underlying mechanisms are complex and current therapeutic strategies mainly focus on symptomatic relief rather than on the intrinsic regeneration of the IVD. This talk will provide an overview of special anatomical features and the composition of the IVD as well as its cellular microenvironment. Selected promising conceptional regenerative approaches will be discussed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 50 - 50
11 Apr 2023
Souleiman F Zderic I Pastor T Gehweiler D Gueorguiev B Galie J Kent T Tomlinson M Schepers T Swords M
Full Access

The quest for optimal treatment of acute distal tibiofibular syndesmotic disruptions is still in progress. Using suture-button repair devices is one of the dynamic stabilization options, however, they may not be always appropriate for stabilization of length-unstable syndesmotic injuries. Recently, a novel screw-suture repair system was developed to address such issues. The aim of this study was to investigate the performance of the novel screw-suture repair system in comparison to a suture-button stabilization of unstable syndesmotic injuries.

Eight pairs of human cadaveric lower legs were CT scanned under 700 N single-leg axial loading in five foot positions – neutral, 15° external/internal rotation and 20° dorsi-/plantarflexion – in 3 different states: (1) pre-injured (intact); (2) injured, characterized by complete syndesmosis and deltoid ligaments cuts simulating pronation-eversion injury types III and IV as well as supination-eversion injury type IV according to Lauge-Hansen; (3) reconstructed, using a screw-suture (FIBULINK, Group 1) or a suture-button (TightRope, Group 2) implants for syndesmotic stabilization, placed 20 mm proximal to the tibia plafond. Following, all specimens were: (1) biomechanically tested over 5000 cycles under combined 1400 N axial and ±15° torsional loading; (2) rescanned. Clear space (diastasis), anterior tibiofibular distance, talar dome angle and fibular shortening were measured radiologically from CT scans. Anteroposterior (AP), axial, mediolateral and torsional movements at the distal tibiofibular joint level were evaluated biomechanically via motion tracking.

In each group clear space increased significantly after injury (p ≤ 0.004) and became significantly smaller in reconstructed compared with both pre-injured and injured states (p ≤ 0.041). In addition, after reconstruction it was significantly smaller in Group 1 compared to Group 2 (p < 0.001). AP and axial movements were significantly smaller in Group 1 compared with Group 2 (p < 0.001). No further significant differences were identified/detected between the groups (p ≥ 0.113).

Although both implant systems demonstrate ability for stabilization of unstable syndesmotic injuries, the screw-suture reconstruction provides better anteroposterior translation and axial stability of the tibiofibular joint and maintains it over time under dynamic loading. Therefore, it could be considered as a valid option for treatment of syndesmotic disruptions.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 58 - 58
2 Jan 2024
Camarero-Espinosa S
Full Access

The anterior cruciate ligament (ACL) is the connective tissue located at the end of long bones providing stability to the knee joint. After tear or rupture clinical reconstruction of the tissue remains a challenge due to the particular mechanical properties required for proper functioning of the tissue. The outstanding mechanical properties of the ACL are characterized by a viscoelastic behavior responsible of the dissipation of the loads that are transmitted to the bone. These mechanical properties are the result of a very specialized graded extracellular matrix that transitions smoothly between the heterotypic cells, stiffness and composition of the ACL and the adjacent bone. Thus, mimicking the zonal biochemical composition, cellular phenotype and organization are key to reset the proper functioning of the ACL.

We have previously shown how the biochemical composition presented to cells in electrospun scaffolds results in haptokinesis, reverting contact-guidance effects.[1] Here, we demonstrate that contact guidance can also be disrupted by structural parameters in aligned wavy scaffolds. The presentation of a wavy fiber arrangement affected the cell organization and the deposition of a specific ECM characteristic of fibrocartilage. Cells cultured in wavy scaffolds grew in aggregates, deposited an abundant ECM rich in fibronectin and collagen II, and expressed higher amounts of collagen II, X and tenomodulin as compared to aligned scaffolds. In-vivo implantation in rabbits of triphasic scaffolds accounting for aligned-wavy-aligned zones showed a high cellular infiltration and the formation of an oriented ECM, as compared to traditional aligned scaffolds.[2]


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 74 - 74
4 Apr 2023
Mariscal G Barrés M Barrios C Tintó M Baixauli F
Full Access

To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails.

A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the AO/OTA classification was performed. Baseline characteristics of each article were obtained, complication measures were analyzed: Peri-implant fracture, reoperations, deep/superficial infection, and mortality. Clinical variables consisted of blood loss (mL), length of stay (days), time of surgery (min) and nº of transfusions. Functional outcomes were also recorded. A meta-analysis was performed with Review Manager 5.4.

Twelve studies were included, nine were retrospective. The reoperations rate was lower in the short nail group and the peri-implant fracture rate was lower in the long nail group (OR 0.58, 95% CI 0.38 to 0.88) (OR 1.88, 95% CI 1.04 to 3.43). Surgery time and blood loss was significantly higher in the long nail group (MD −12.44, 95% CI −14.60 to −10.28) (MD −19.36, 95% CI −27.24 to −11.48). There were no differences in functional outcomes.

The short intramedullary nail has a higher risk of peri-implant fracture; however, the reoperation rate is lower compared to the long nail. Blood loss and surgery time was higher in the long nail group.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 78 - 78
4 Apr 2023
Voropai V Nieher M Kratsch A Kirchner W Giggel B Lohmann C Bertrand J Weißmantel S Döring J
Full Access

Total knee arthroplasty is one of the most common surgeries. About 92% of all implanted knee endorposthesis in 2020 were manufactured from uncoated CoCrMo articulating on ultra-high-molecular-weight polyethylene. All articluations generate wear particles and subsequent emission of metal ions due to the mechanical loading. These wear particles cause diverse negative reactions in the surrounding tissues and can lead to implant loosening. Coating technologies might offer the possibility to reduce this wear. Therefore, we investigated the applicability of tetrahedral amorphous carbon (ta-C) coating on CoCrMo alloy.

Polished specimens made of CoCrMo wrought alloy according to ISO 5832-12 were coated with ta-C coatings with different layer structure using pulsed laser deposition (PLD). This process allows the deposition of ta-C coatings with low internal stress using an additional relaxation laser. Surface quality and mechanical properties of the coating were characterised using optical surface measurements (NanoFocus μsurf expert, NanoFocus AG) and a nanoindentation tester NHT3 (Anton Paar GmbH). Scratch tests were performed on Micro Scratch Tester MST3 (Anton Paar TriTec SA) to define the coating adhesion. Pin-on-plate tribological tests, with a polyethylene ball sliding on the ta-C-coated plate under a defined load according to ISO 14243-1 were performed using a linear tribometer (Anton Paar GmbH) to evaluate the tribological and wear properties.

The ta-C coatings showed a mean roughness Ra of 5-20 nm and a hardness up to 60 GPa (n=3). The adhesion of the ta-C coatings (n=3) was comparable to the commercial coatings like TiN and TiNbN. The pin-on-plate tests showed an improvement of tribological properties in comparison with the polished uncoated CoCrMo specimens (n=3).

The ta-C coatings applied by DLP technology show increased hardness compared to the base material and sufficient adhesion. Further research will be needed to investigate the optimal coating strategy for implant coating.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 81 - 81
4 Apr 2023
Zühlke A Banicevic I Obradovic B Gasik M
Full Access

Design of bone tissue engineering scaffolds imposes a number of requirements for their physical properties, in particular porosity and mechanical behaviour. Alginates are known as a potential material for such purposes, usually deploying calcium as a cross-linker. Calcium over-expression was reported having proinflammatory effect, which is not always desirable. Contrary to this, barium has better immunomodulatory outcome but data for barium as a cross-linker are scarce. In this work the objective was to produce Ba-linked alginates and compare their viscoelastic properties with Ca-linked controls in vitro.

Sodium alginate aqueous solution (1 wt%) with 0.03 wt.% CaCl2 is gelled in dialysis tubing immersed in 27 mM CaCl2 (controls) or BaCl2, for 48 h, followed by freeze-drying and rehydration (with 0.3 wt.% CaCl2 and 0.8 wt.% NaCl). Hydrogel discs (diameter 8-10 mm, thickness 4-6 mm) were assessed in dry and wet (DMEM immersed) states by dynamic mechanical analysis (DMA) under compressive creep conditions with increased loads, frequency scans and strain-controlled sweeps in physiological range (0.1-20 Hz) at 25°C and 37°C. Resulting data were analysed by conventional methods and by a model-free BEST (Biomaterials Enhanced Simulation Testing) to extract invariant values and material functions.

Significant differences were observed in properties of Ba-linked hydrogel scaffolds vs. Ca-linked controls. Specifically, for the similar porosity Ba-samples exhibited lower creep compliance, higher dynamical stiffness and lower loss factor in the whole studied range. Invariant modulus exhibited a non-linear decay vs. applied stress. These differences were observed in both dry and wet states and temperatures.

Use of barium as a cross-linker for alginates allows further modification of biomechanical properties of the scaffolds for better compliancy to the tissues in the application. Barium release might have an immunomodulating effect but also promote ion exchange for osteogenesis due to additional Ca/Ba concentration gradient.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 82 - 82
4 Apr 2023
Kokozidou M Gögele C Pirrung F Hammer N Werner C Kohl B Hahn J Breier A Schöpfer M Meyer M Schulze-Tanzil G
Full Access

Although autografts represent the gold standard for anterior cruciate ligament (ACL) reconstruction, tissue-engineered ACLs provide a prospect to minimize donor site morbidity and limited graft availability. This given study characterizes the ligamentogenesis in embroidered poly(L-lactide-co-ε-caprolactone) (P(LA-CL)) / polylactic acid (PLA) constructs using a dynamic nude mice xenograft model. (P(LA-CL))/PLA scaffolds remained either untreated (co) or were functionalized by gas fluorination (F), collagen foam cross-linked with hexamethylene diisocyanate (HMDI) (coll), or gas fluorination combined with the foam (F+coll). Cell free constructs or those seeded for 1 week with lapine ACL ligamentocytes were implanted into nude mice for 12 weeks. Following explantation, biomechanical properties, cell vitality and content, histopathology of scaffolds (including organs: liver, kidney, spleen), sulphated glycosaminoglycan (sGAG) contents and biomechanical properties were assessed.

Implantation of the scaffolds did not negatively affect mice weight development and organs, indicating biocompatibility. All scaffolds maintained their size and shape for the duration of the implantation. A high cell viability was detected in the scaffolds prior to and following implantation. Coll or F+coll scaffolds seeded with cells yielded superior macroscopic properties when compared to the controls. Mild signs of inflammation (foreign-body giant cells, hyperemia) were limited to scaffolds without collagen. Microscopical score values and sGAG content did not differ significantly. Although remaining stable in vivo, elastic modulus, maximum force, tensile strength and strain at Fmax were significantly lower in the in vivo compared to the samples cultured 1 week in vitro, but did not differ between scaffold subtypes, except for a higher maximum force in F+coll compared with F samples (in vivo). Scaffold functionalization with fluorinated collagen foam provides a promising approach for ACL tissue engineering.

(shared first authorship)

Acknowledgement: The study was supported by DFG grants SCHU1979/9-1 and SCHU1979/14-1.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 83 - 83
4 Apr 2023
Loukopoulou C Vorstius J Paxton J
Full Access

To ensure clinical relevance, the in vitro engineering of tissues for implantation requires artificial replacements to possess properties similar to native anatomy. Our overarching study is focussed on developing a bespoke bone-tendon in vitro model replicating the anatomy at the flexor digitorum profundus (FDP) tendon insertion site at the distal phalanx. Anatomical morphometric analysis has guided FDP tendon model design consisting of hard and soft tissue types. Here, we investigate potential materials for creation of the model's bone portion by comparison of two bone cements; brushite and genex (Biocomposites Ltd).

3D printed molds were prepared based on anatomical morphometric analysis of the FDP tendon insertion site and used to cast identical bone blocks from brushite and genex cements. Studies assessing the suitability of each cement type were conducted e.g. setting times, pH on submersion in culture medium and interaction with fibrin gels. Data was collected using qualitative imaging and qualitative measurements (N=3,n=6) for experimental conditions.

Both brushite (BC) and genex (GC) cements could be cast into bespoke molds, producing individual blocks and were mixed/handled with appropriate setting times. On initial submersion in culture medium, BC caused a reduction in pH values (7.49 [control]) to 6.85) while GC remained stable (7.59). Reduction in pH value also affected fibrin gel interaction where gel was seen to be detaching/not forming around BC and medium discolouration was noted. This was not observed in GC. While GC outperformed BC in initial tests, repeated washing of BC led to pH stabilisation (7.5,3xwashes), consistent with their further use in this model.

This study has compared BC and GC as materials for bone block production. Both materials show promise, and current work assessing material properties and cell proliferation are needed to inform our choice for use in our FDP-tendon-bone interface model.

This research was supported by an ORUK Studentship award (ref:533). Genex was kindly provided by Biocomposites, Ltd.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 7 - 7
4 Apr 2023
Bottomley J Al-Dadah O
Full Access

Meniscal tears are the most common injury in the knee, affecting 66/100,000 people/year. Surgical treatment includes arthroscopic meniscectomy or meniscal repair. Little is known regarding medium-term outcomes following these procedures in isolated meniscal tears. This study aims to quantitatively evaluate patients with meniscal tears, and those who have undergone meniscectomy and meniscal repair using validated patient reported outcome measures (PROMs), further exploring factors which affect surgical outcomes.

This observational study screened 334 patients who underwent arthroscopic surgery at South Tyneside Hospital since August 2013. 134 patients with isolated meniscal tears were invited to complete postal PROMs. A combination of patient notes and radiological imaging was used to collect information of interest including age, gender, knee-laterality, injured meniscus, tear pattern, procedure performed, complications, and associated injuries.

A total of 115 patients (pre-operative patients with current meniscal tear (n=36), meniscectomy (n=63), meniscal repair (n=16)) were included in the analysis with 96% successful PROM completion. Both meniscectomy and meniscal repairs (mean 55-months follow-up) showed better outcomes than pre-operative patients with meniscal tears. Meniscal repairs demonstrated superior outcomes across all PROMs when compared to meniscectomy, with a greater mean overall KOOS score of 17.2 (p=0.009). Factors including higher pre-operative Kellgren-Lawrence Grade, pre-operative articular cartilage lesions and bilateral meniscectomies were shown to negatively influence outcomes.

Both meniscectomy and meniscal repair maintain clinical benefit at mean 55-months follow-up, affirming their use for treatment of meniscal tears. When feasible, meniscal repair should be performed preferentially over meniscectomy in isolated meniscal tears. Identified predictive factors allow adequate treatment stratification in specific patient groups.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 8 - 8
17 Nov 2023
Alieldin E Samir M
Full Access

Abstract

Introduction

The medial meniscus is crescent shaped and it is wider posteriorly than anteriorly. It covers up to 60 % of the articular surface of medial tibial condyle and helps with the loading distribution in the medial compartment. Meniscal lesions occur in association with ACL tears in 60 % of the time. The posterior aspect of the menisco-capsular junction is known as the meniscal rampzone. If not addressed during surgery, it could lead to unfavourable results.

Objective

Incidence of ramp lesion following ACL injuries.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 18 - 18
11 Apr 2023
Kühl J Gorb S Klüter T Naujokat H Seekamp A Fuchs S
Full Access

Critical-sized bone defects can result from trauma, inflammation, and tumor resection. Such bone defects, often have irregular shapes, resulting in the need for new technologies to produce suitable implants. Bioprinting is an additive manufacturing method to create complex and individualised bone constructs, which can already include vital cells.

In this study, we established an extrusion-based printing technology to produce osteoinductive scaffolds based on polycaprolactone (PCL) combined with calcium phosphate, which is known to induce osteogenic differentiation of stem cells.

The model was created in python based on the signed distance functions. The shape of the 3D model is a ring with a diameter of 20 mm and a height of 10 mm with a spongiosa-like structure. The interconnected irregular pores have a diameter of 2 mm +/− 0.2 mm standard deviation.

Extrusion-based printing was performed using the BIO X6. To produce the bioink, PCL (80 kDa) was combined with calcium phosphate nanopowder (> 150 nm particle size) under heating. After printing, 5 × 106 hMSC were seeded on the construct using a rotating incubator.

We were able to print a highly accurate ring construct with an interconnected pore structure. The PCL combined with calcium phosphate particles resulted in a precise printed construct, which corresponded to the 3D model. The bioink containing calcium phosphate nanoparticles had a higher printing accuracy compared to PCL alone. We found that hMSC cultured on the construct settled in close proximity to the calcium phosphate particles. The hMSC were vital for 22 days on the construct as demonstrated by life/dead staining.

The extrusion printing technology enables to print a mechanically stable construct with a spongiosa-like structure. The porous PCL ring could serve as an outer matrix for implants, providing the construct the stability of natural bone. To extend this technology and to improve the implant properties, a biologised inner structure will be integrated into the scaffold in the future.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 11 - 11
17 Nov 2023
Wahdan Q Solanke F Komperla S Edmonds C Amos L Yap RY Neal A Mallinder N Tomlinson JE Jayasuriya R
Full Access

Abstract

INTRODUCTION

In the NHS the structure of a “regular healthcare team” is no longer the case. The NHS is facing a workforce crisis where cross-covering of ward-based health professionals is at an all-time high, this includes nurses, doctors, therapists, pharmacists and clerks. Comprehensive post-operative care documentation is essential to maintain patient safety, reduce information clarification requests, delays in rehabilitation, treatment, and investigations. The value of complete surgical registry data is emerging, and in the UK this has recently become mandated, but the completeness of post-operative care documentation is not held to the same importance, and at present there is no published standard. This project summarises a 4-stage approach, including 6 audit cycles, >400 reviewed operation notes, over a 5 year period.

OBJECTIVE

To deliver a sustainable change in post operative care documentation practices through quality improvement frameworks.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 13 - 13
17 Nov 2023
Armstrong R McKeever T McLelland C Hamilton D
Full Access

Abstract

Objective

There is no specific framework for the clinical management of sports related brachial plexus injuries. Necessarily, rehabilitation is based on injury presentation and clinical diagnostics but it is unclear what the underlying evidence base to inform rehabilitative management.

Methods

A systematic review of the literature was undertaken in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We applied the PEO criteria to inform our search strategy to find articles that reported the rehabilitative management of brachial plexus injuries sustained while playing contact sports. An electronic search of Medline, CINAHL, SPORTDiscus and Web of Science from inception to 3rd November 2022 was conducted. MESH terms and Boolean operators were employed. We applied an English language restriction but no other filters. Manual searches of Google Scholar and citation searching of included manuscripts were also completed. All study types were considered for inclusion provided they were published as peer-reviewed primary research articles and contained relevant information. Two investigators independently carried out the searches, screened by title, abstract and full text. Two researchers independently extracted the data from included articles. Data was cross-checked by a third researcher to ensure consistency. To assess internal validity and risk of bias, the Joanna Briggs Institute (JBI) critical appraisal tools were utilised.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 102 - 102
4 Apr 2023
Lu V Zhou A Hussain H Thahir A Krkovic M
Full Access

A hot swollen joint is a commonly encountered condition in clinical practice. With a broad range of differentials, septic arthritis (SA) is perhaps one of the most concerning. Treated by culture-specific antibiotics and arthroscopic lavage, some patients require multiple washouts. We aimed to determine:

(1) What are the risk factors for development of SA?

(2) What are the risk factors for repeat washout in SA patients?

(3) What are the important clinical differences between a periprosthetic joint infection (PJI) and SA cohort?

All patients presenting to the emergency department, orthopaedic, and rheumatology clinics between January 2020 to January 2021 with a hot, swollen joint were retrospectively evaluated. Patients with previous trauma on the ipsilateral joint, with data missing from their medical records in any of the variables required for analysis, <24 months follow-up were excluded.

Variables of interest in the three-month period preceding the diagnosis of SA were compared between SA and non-SA patients. Factors with a p-value of p<0.100 in univariate analysis were included in a stepwise multivariate logistic regression model. Similar analyses were performed to compare SA patients with multiple washouts with those needing one washout. Demographical and clinical data for PJI patients were collected to delineate important differences with SA cohort.

211 patients were included (SA:28;PJI:24;pseudogout:32;gout:26;others:101). Multivariate analysis showed rheumatoid arthritis (RA), skin infection, and liver disease were risk factors for SA. Amongst patients with septic arthritis, multivariate analysis showed that WBC levels above normal limits (3.6-10.5×109 cells/L) and RA were risk factors for multiple washouts.

Between the SA and PJI cohorts, BMI (p=0.002) was significantly lower in the former, whilst WBC level (p=0.023) and CRP (p<0.0001) was significantly higher in the former.

Early diagnosis of septic arthritis requires understanding the risk factors, namely RA, skin infection, and liver disease. Considering PJI and septic arthritis as the same entity can lead to wrong clinical judgement, and clinicians should be aware of important differences. We believe that the models in this study are of prognostic value to clinicians who are presented with the common presenting compliant of a hot swollen joint.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 14 - 14
4 Apr 2023
Luk J
Full Access

In this study, we aimed to investigate tibiofemoral and allograft loading parameters after OCA transplantation using tibial plateau shell grafts to characterize the clinically relevant biomechanics that may influence joint kinematics and OCA osseointegration after transplantation. The study was designed to test the hypothesis that there are significant changes in joint loading after tibial plateau OCA transplantation that may require unique post-operative rehabilitation regimens in patients to restore balance in the knee joint.

Fresh-frozen cadaveric knees (n=6) were thawed and mounted onto a 6 DOF KUKA robot. Specimens were size matched to +2 mm for the medial-to-lateral width of the medial tibial hemiplateaus. Three specimens served as allograft recipient knees and three served as donor knees. Recipient knees were first tested in their native state and then tested with size-matched medial tibial hemiplateau shell grafts (n=3) prepared from the donor knees using custom-cut tab-in-slot and subchondral drilling techniques. Tekscan sensors were placed in the joint spaces to evaluate the loading conditions under 90N biaxial loading at full extension of the knee before and after graft placement. The I-Scan system used in conjunction analyzed the total force, pressure distribution, peak pressure, and center of force within the joint space.

Data demonstrated significant difference (p<0.05) in joint space loading after graft implantation compared to controls in both lateral and medial tibial plateaus. The I-Scan pressure mapping system displayed changes in femoral condylar contact points as well.

The results demonstrated that joint space loading was significantly different (p<0.05) between all preoperative and postoperative cadaveric specimens. Despite the best efforts to size match grafts, slight differences in the host's joint geometry resulted in shifts of contact areas between the tibial plateau and femoral condyle therefore causing either an increase or decrease in pressure measured by the sensor. This concludes that accuracy in graft size matching is extremely important to restoring close to normal loading across the joint and this can be further ensured through postoperative care customized to the patient after OCA surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 22 - 22
11 Apr 2023
Sun Y
Full Access

To analyze the effect of tooth extraction site preservation on bone mineral density 6 months after surgery.

From 2020 to 2021, two adjacent teeth (37, 38) of the same patient were extracted at the same time, and then 37 were selected for site preservation, implanted with Bio-oss bone powder, covered with double Bio-gide membrane, reduce tension and sutured. After 6 months of self-healing, 38 was taken CBCT, and the gray value measurement tool in the software was used to measure the bone mineral density of 37 bone graft areas and 38 extraction sockets.

Bone density was high in the center of the bone graft area after the extraction site, and the density decreased in the adjacent alveolar socket, but the gray value was still higher than 38 for natural healing.

Extraction site surgery can improve bone mass and quality at the extraction site. It is good for implanting.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 70 - 70
17 Apr 2023
Flood M Gette P Cabri J Grimm B
Full Access

For clinical movement analysis, optical marker-based motion capture is the gold standard.

With the advancement of AI-driven computer vision, markerless motion capture (MMC) has emerged. Validity against the marker-based standard has only been examined for lightly-dressed subjects as required for marker placement. This pilot study investigates how different clothing affects the measurement of typical gait metrics.

Gait tests at self-selected speed (4 km/h) were performed on a treadmill (Motek Grail), captured by 9 cameras (Qualisys Miqus, 720p, f=100Hz) and analyzed by a leading MMC application (Theia, Canada). A healthy subject (female, h=164cm, m=54kg) donned clothes between trials starting from lightly dressed (LD: bicycle tight, short-sleeved shirt), adding a short skirt (SS: hip occlusion) or a midi-skirt (MS: partial knee occlusion) or street wear (SW: jeans covering ankle, long-sleeved blouse), the lattern combined with a short jacket (SWJ) or a long coat (SWC). Gait parameters (mean±SD, t=10s) calculated (left leg, mid-stance) were ankle pronation (AP-M), knee flexion (KF-M), pelvic obliquity (PO-M) and trunk lateral lean (TL-M) representing clinically common metrics, different joints and anatomic planes. Four repetitions of the base style (LD) were compared to states of increased garment coverage using the t-test (Bonferroni correction).

For most gait metrics, differences between the light dress (LD) and various clothing styles were absent (p>0.0175), small (< 2SD) or below the minimal clinically important differences (MCID). For instance, KF-M was for LD=10.5°±1.7 versus MD=12.0°±0.5 (p=0.07) despite partial knee cover. AP-M measured for LD=5.2°±0.6 versus SW=4.1°±0.7 (p<0.01) despite ankle cover-up. The difference for KF-M between LD=10.5°±1.7 versus SWL=6.0°±0.9, SW and SWJ (7.6°±1.5, p<0.01) indicates more intra-subject gait variability than clothing effect.

This study suggests that typical clothings styles only have a small clinically possibly negligible effect on common gait parameters measured with MMC. Thus, patients may not need to change clothes or be instructed to wear specific garments. In addition to avoiding marker placement, this further increases speed, ease and economy of clinical gait analysis with MMC facilitating high volume or routine application.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 73 - 73
2 Jan 2024
Vinhas A Rodrigues M Gonçalves A Gomes M
Full Access

Common tendon injuries impair healing, leading to debilitation and an increased re-rupture risk. The impact of oxygen-sensing pathways on repair mechanisms, vital in regulating inflammation and fibrosis, remains unclear despite their relevance in tendon pathologies. Recent studies show that pulsed electromagnetic field (PEMF) reduce inflammation in human tendon cells (hTDCs) and in hypoxia-induced inflammation. We investigated the hypoxia's impact (1% and 2% oxygen tension) using magnetic cell sheet constructs (IL-1β-magCSs) primed with IL-1β. IL-1β-magCSs were exposed to low OT (1h, 4h,6h) in a hypoxic chamber. To confirm the role of PEMF (5Hz, 4mT, 50% duty cycle) on hypoxia modulation, IL-1β-magCSs, previously exposed to OT, were 1h-stimulated with PEMF. Our results show a significant increase in HIF- 1a and HIF-2a expression on IL-1β-magCSs after exposure to 2%-OT at all time points, compared to 1%- OT and normoxia. TNFa, IL-6, and IL-8 expression increased after 6 hours of 1%-OT exposure. PEMF stimulation of hypoxic IL-1β-magCSs led to decreased pro-inflammatory genes and increased anti-inflammatory (IL-4,IL-10) expression compared to unstimulated magCSs. IFN-g, TNF-α, and IL-6 release increased after 6 hours, regardless of %-OT, while IL-10 levels tended to rise after PEMF stimulation at 2%-OT. Also, NFkB expression was increased on IL-1β-magCSs exposed to 4 h and 6 h of 2%-OT, suggesting a link between NFkB and the production of pro-inflammatory factors. Moreover, PEMF stimulation showed a significantly decreased NFkB level in IL-1β-magCSs.

Overall, low OT enhances expression of hypoxia-associated genes and inflammatory markers in IL-1β-magCSs with the involvement of NFkB. PEMF modulates the response of magCSs, previously conditioned to hypoxia and to inflammatory triggers, favouring expression of anti-inflammatory genes and proteins, supporting PEMF impact in pro-regenerative tendon strategies.

Acknowledgements: ERC CoG MagTendon(No.772817), FCT under the Scientific Employment Stimulus-2020.01157.CEECIND. Thanks to Hospital da Prelada for providing tendon tissue samples (Portugal), and TERM

RES Hub (Norte-01-0145-FEDER-022190).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 29 - 29
2 Jan 2024
Klatte-Schulz F Gehlen T Bormann N Tsitsilonis S Manegold S Schmock A Melzer J Schmidt-Bleek K Geißler S Duda G Sawitzki B Wildemann B
Full Access

Early identification of patients at risk for impaired tendon healing and corresponding novel therapeutic approaches are urgent medical needs. This study aimed to clarify the role of CD3+ T-cells during acute Achilles tendon (AT) healing. Blood and hematoma aspirate were taken from 26 patients during AT reconstruction, and additional blood samples were obtained during clinical follow-up at 6, 26 and 52 weeks after surgery. T-cell subsets were analyzed by flow cytometry using CD3, CD4, CD8, CD11a, CD57 and CD28 antibodies. Clinical follow-up included functional tests, MRI assessments, and subjective questionnaires. In vitro, the functional behavior of patient-derived tenocytes was investigated in co-cultures with autologous unpolarized CD4+ or CD8+ T-cells, or IFNy-polarized CD8+ or IL17-polarized CD4+ Tcells (n=5-6). This included alterations in gene expression (qPCR), MMP secretion (ELISA), migration rate (scratch wound healing assay) or contractility (collagen gels). Analysis revealed that elevated CD4+ T-cell levels and reduced CD8+ T-cell levels (increased CD4/CD8 ratio) in hematoma aspirate and pre-operative blood were associated with inferior clinical outcomes regarding pain and function at 26 and 52 weeks. Increased levels of CD8+ -memory T-cell subpopulations in blood 6 weeks after surgery were associated with less tendon elongation. In vitro, tenocytes showed increased MMP1/2/3 levels and collagen III/I ratio in co-culture with unpolarized and/or IL17-polarized CD4+ T-cells compared to unpolarized CD8+ T-cells. This coincided with increased IL17 receptor expression in tenocytes co-cultured with CD4+ T-cells. Exposure of tenocytes to IL17-polarized CD4+ T-cells decreased their migration rate and increased their matrix contractility, especially compared to IFNy-polarized CD8+ T-cells. The CD4+ /CD8+ T-cell ratio could serve as prognostic marker for early identification of patients with impaired AT healing potential. Local reduction of CD4+ T-cell levels or their IL17 secretion represent a potential therapeutic approach to improve AT healing and to prevent weakening of the tendon ECM.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 76 - 76
2 Jan 2024
Zamboulis D Ali F Thorpe C
Full Access

Energy storing tendons such as the human Achilles and equine superficial digital flexor tendon (SDFT) are prone to age-related injury. Tendons have poor healing capacity and a lack of effective treatments can lead to ongoing pain, reduced function and re-injury. It is therefore important to identify the mechanisms underpinning age-related tendinous changes in order to develop more effective treatments. Our recent single cell sequencing data has shown that tendon cell populations have extensive heterogeneity and cells housed in the tendon interfascicular matrix (IFM) are preferentially affected by ageing. There is, however, a lack of established surface markers for cell populations in tendon, limiting the capacity to isolate distinct cell populations and study their contribution to age-related tendon degeneration. Here, we investigate the presence of the cell surface proteins MET proto-oncogene (MET), integrin subunit alpha 10 (ITGA10), fibroblast activation protein alpha (FAP) and platelet derived growth factor receptor alpha (PDGFRA) in the equine SDFT cell populations and their co-localisation with known markers.

Using Western blot we validated the specificity of selected antibodies in equine tissue before performing immunohistochemistry to establish the location of the respective proteins in the SDFT. We subsequently used double labelling immunofluorescence with the established mural cell marker desmin (DES) to distinguish between tenocyte and mural cell populations.

In situ, MET, ITGA10, and FAP presence was found in cells throughout the tendon whereas PDGFRA was present in cells within the IFM. Double labelling immunofluorescence with the mural cell marker DES showed lack of co-localisation between PDGFRA and DES suggesting PDGFRA is labelling an IFM cell population distinct from those associated with blood vessels.

PDGFRA is a promising target for the specific cell sorting of IFM-localised tenocytes, enabling their isolation and subsequent characterisation.

Acknowledgments: The authors acknowledge the Biotechnology and Biological Sciences Research Council (BB/W007282/1) for funding this work.