Aim. Prosthetic joint infections (PJI) remain a great challenge in orthopedic surgery with a high mortality rate. It is particularly complicated by biofilms and infections caused by Methicillin-resistant Staphylococcus aureus (MRSA). It concurrently shields bacteria from host immune responses and confers resistance to antibiotics. This study aims to investigate the efficacy of radioimmunotherapy as an innovative therapeutic modality to address the challenges posed by MRSA and its biofilm. Method. We induced specific monoclonal antibodies 4497-IgG1 as carriers, which target wall teichoic acids (WTA) existing on MRSA and its biofilm. Radionuclides actiniumr-225 (. 225. Ac, α-emitter) and lutetium-177 (. 177. Lu, β-emitter) were conjugated with mAbs using DOTA as chelator. Quality control was assessed using thin layer chromatography and immunoreactivity assays. . 225. Ac- and . 177. Lu-labelled 4497-IgG1 were employed to evaluate the susceptibility of MRSA and its biofilm to the radioimmunotherapy in vitro. Planktonic MRSA and biofilms, at concentrations of 10. 8. and 10. 7. CFU/mL, were incubated at 37°C for 60 minutes in PBS containing either . 225. Ac-mAb (0 - 14.8 kBq) or . 177. Lu-mAb (0 - 14.8 MBq). Radiolabelled dunituximab and free radionuclides serve as isotype-matched negative control. The bacterial viability and metabolic activity were subsequently quantified using CFU and XTT assays. Results. The radiochemical purity of the . 225. Ac-mAbs and . 177. Lu-mAbs complex were determined to be 95.4% and 96.16%. Immunoreactivity fractions of them were measured at 81.8% and 80.8%. . 225. Ac-mAbs and . 177. Lu-mAbs exhibited significant and dose-dependent antimicrobial effects on both planktonic MRSA and biofilm. . 225. Ac- and . 177. Lu-4497IgG1 at doses of 7.4 kBq and 7.4 MBq resulted in more than 4-log reduction in bacterial counts. In biofilms, 2-log reduction at the highest . 225. Ac radioactivity of 14,8kBq. The . 177. Lu complex showed a strong dose-dependent effect, with a reduction of up to 4-log. The XTT assay confirmed these findings, showing a decrease in metabolic activity corresponding to a decrease in bacterial counts, and a slight increase in metabolic activity at the lower dose. Conclusions. Our study demonstrates the efficacy of . 225. Ac and . 177. Lu-labelled 4497-IgG1 antibodies in mediating dose-dependent
Aim. Evaluate if Neutrophil Extracellular Traps related biomarkers (citrullinated histone H3 [H3Cit], cellfree DNA [cfDNA], and myeloperoxidase) are increased in synovial fluid of patients with PJI and investigate the diagnostic accuracy of NET formation biomarkers for PJI. Method. Patients who underwent hip or knee revision total joint arthroplasty were categorised into two groups according to the Second International Consensus Meeting on Musculoskeletal Infection (2018) criteria. Sixteen patients were classified as infected and 16 as non-infected. cf-DNA, myeloperoxidase and H3Cit were measured in synovial fluid collected during surgery. Sensitivity, specificity, and receiver operating characteristic (ROC) curve were calculated. Results. Patients with PJI presented significantly higher levels of synovial fluid cf-DNA (105.5 ng/ml ± 58.3 vs 1.9 ± 1.2, p>0.0001), myeloperoxidase (1575 pg/ml ± 826 vs 50.16 ± 100, p<0.0001) and citrullinated histone H3 (1.688 ± 1.214 vs 13.88 ± 24.4, p < 0.0001). In the ROC curve analyses, the area under the curve for cf-DNA, myeloperoxidase and H3cit were 1 [0.89 – 1], 0.98 [0.86 – 1], and 0.94 [0.8 – 0.99], respectively. The sensitivity for detecting PJI using synovial fluid was 100% for cf-DNA, 93,7% for myeloperoxidase, and 87,5% for H3cit. The sensitivity for cf-DNA and myeloperoxidase was 100%, and 87,5 % for H3cit. Conclusions. Our results show that neutrophils within periprosthetic microenvironment release NETs as part of the
Aim. Chemical debridement is a fundamental step during Periprosthetic joint infection (PJI) surgery. Antiseptic solutions are commonly used, but evidence on the optimal antiseptic, concentration, and irrigation time is lacking. The aim of this study is to analyze and compare the anti-biofilm capacity of povidone iodine, H. 2. 0. 2. , acetic acid and Bactisure™ after different exposure times, as well as their combinations. Method. Surgical steel discs inoculated with methicillin susceptible (MSSA) and resistant S. aureus (MRSA), P. aeruginosa, and S. epidermidis were exposed to the following antiseptic solutions: 0.3% (PI0.3) and 10% povidone iodine (PI10), H. 2. 0. 2. , 3% Acetic acid (AA3) and Bactisure™. Combinations included AA3, H. 2. 0. 2. , and PI10 in various orders. Exposure time for the antiseptics solutions was 1, 3 and 5 minutes, while combinations had a 9-minute total exposure, 3 minutes per antiseptic sequentially. All experiments were performed in triplicate and with a sterile saline control. nThe reduction in colony-forming units (CFU) was measured after sonication, and biofilm structure was analyzed via scanning electron microscopy. Results. PI showed the highest antibiofilm activity. PI0.3 eradicated bacteria on the discs after 3 and 5 minutes of exposure, but only achieved a 77.1% reduction after 1 minute. After PI10 treatment, we did not recover any bacteria regardless of exposure time. H. 2. 0. 2. , AA3, and Bactisure™ reached a significantly lower bacterial decrease at all exposure times compared to PI0.3 and PI10. AA3 was less effective against MSSA and S. epidermidis. H. 2. 0. 2. showed less activity against MRSA than PI0.3, PI10, and Bactisure™. Combinations of antiseptics starting with AA3 showed the best results in terms of CFU reduction and cell viability. Conclusions. We propose a sequential combination of AA3 + H. 2. 0. 2. + PI10 with an exposure time of 9 minutes for the chemical debridement in PJI surgery. First, AA3 performs debridement and disruption of the biofilm. Then, H. 2. 0. 2. has a
Aims. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against Staphylococcus aureus. Methods. We performed in vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10 µM of copper. We determined the minimum
The efficacy of saline irrigation for treatment of implant-associated infections is limited in the presence of porous metallic implants. This study evaluated the therapeutic efficacy of antibiotic doped bioceramic (vancomycin/tobramycin-doped polyvinyl alcohol composite (PVA-VAN/TOB-P)) after saline wash in a mouse infection model implanted with titanium cylinders. Air pouches created in female BalBc mice by subcutaneous injection of air. In the first of two independent studies, pouches were implanted with titanium cylinders (400, 700, and 100 µm pore sizes) and inoculated with Aims
Methods
The optimum type of antibiotics and their administration route for treating Gram-negative (GN) periprosthetic joint infection (PJI) remain controversial. This study aimed to determine the GN bacterial species and antibacterial resistance rates related to clinical GN-PJI, and to determine the efficacy and safety of intra-articular (IA) antibiotic injection after one-stage revision in a GN pathogen-induced PJI rat model of total knee arthroplasty. A total of 36 consecutive PJI patients who had been infected with GN bacteria between February 2015 and December 2021 were retrospectively recruited in order to analyze the GN bacterial species involvement and antibacterial resistance rates. Antibiotic susceptibility assays of the GN bacterial species were performed to screen for the most sensitive antibiotic, which was then used to treat the most common GN pathogen-induced PJI rat model. The rats were randomized either to a PJI control group or to three meropenem groups (intraperitoneal (IP), IA, and IP + IA groups). After two weeks of treatment, infection control level, the side effects, and the volume of antibiotic use were evaluated.Aims
Methods
We aimed to determine the concentrations of synovial vancomycin and meropenem in patients treated by single-stage revision combined with intra-articular infusion following periprosthetic joint infection (PJI), thereby validating this drug delivery approach. We included 14 patients with PJI as noted in their medical records between November 2021 and August 2022, comprising eight hip and seven knee joint infections, with one patient experiencing bilateral knee infections. The patients underwent single-stage revision surgery, followed by intra-articular infusion of vancomycin and meropenem (50,000 µg/ml). Synovial fluid samples were collected to assess antibiotic concentrations using high-performance liquid chromatography.Aims
Methods
Bone regeneration and repair are crucial to ambulation and quality of life. Factors such as poor general health, serious medical comorbidities, chronic inflammation, and ageing can lead to delayed healing and nonunion of fractures, and persistent bone defects. Bioengineering strategies to heal bone often involve grafting of autologous bone marrow aspirate concentrate (BMAC) or mesenchymal stem cells (MSCs) with biocompatible scaffolds. While BMAC shows promise, variability in its efficacy exists due to discrepancies in MSC concentration and robustness, and immune cell composition. Understanding the mechanisms by which macrophages and lymphocytes – the main cellular components in BMAC – interact with MSCs could suggest novel strategies to enhance bone healing. Macrophages are polarized into pro-inflammatory (M1) or anti-inflammatory (M2) phenotypes, and influence cell metabolism and tissue regeneration via the secretion of cytokines and other factors. T cells, especially helper T1 (Th1) and Th17, promote inflammation and osteoclastogenesis, whereas Th2 and regulatory T (Treg) cells have anti-inflammatory pro-reconstructive effects, thereby supporting osteogenesis. Crosstalk among macrophages, T cells, and MSCs affects the bone microenvironment and regulates the local immune response. Manipulating the proportion and interactions of these cells presents an opportunity to alter the local regenerative capacity of bone, which potentially could enhance clinical outcomes. Cite this article:
Aims. This study investigated vancomycin-microbubbles (Vm-MBs) and meropenem (Mp)-MBs with ultrasound-targeted microbubble destruction (UTMD) to disrupt biofilms and improve
Delayed postoperative inoculation of orthopaedic implants with persistent wound drainage or bacterial seeding of a haematoma can result in periprosthetic joint infection (PJI). The aim of this in vivo study was to compare the efficacy of vancomycin powder with vancomycin-eluting calcium sulphate beads in preventing PJI due to delayed inoculation. A mouse model of PJI of the knee was used. Mice were randomized into groups with intervention at the time of surgery (postoperative day (POD) 0): a sterile control (SC; n = 6); infected control (IC; n = 15); systemic vancomycin (SV; n = 9); vancomycin powder (VP; n = 21); and vancomycin bead (VB; n = 19) groups. Delayed inoculation was introduced during an arthrotomy on POD 7 with 1 × 105 colony-forming units (CFUs) of a bioluminescent strain of Aims
Methods
Continuous local antibiotic perfusion (CLAP) has recently attracted attention as a new drug delivery system for orthopaedic infections. CLAP is a direct continuous infusion of high-concentration gentamicin (1,200 μg/ml) into the bone marrow. As it is a new system, its influence on the bone marrow is unknown. This study aimed to examine the effects of high-concentration antibiotics on human bone tissue-derived cells. Cells were isolated from the bone tissue grafts collected from six patients using the Reamer-Irrigator-Aspirator system, and exposed to different gentamicin concentrations. Live cells rate, apoptosis rate, alkaline phosphatase (ALP) activity, expression of osteoblast-related genes, mineralization potential, and restoration of cell viability and ALP activity were examined by in vitro studies.Aims
Methods
To investigate the efficacy of ethylenediaminetetraacetic acid-normal saline (EDTA-NS) in dispersing biofilms and reducing bacterial infections. EDTA-NS solutions were irrigated at different durations (1, 5, 10, and 30 minutes) and concentrations (1, 2, 5, 10, and 50 mM) to disrupt Aims
Methods
This study was designed to characterize the recurrence incidence and risk factors of antibiotic-loaded cement spacer (ALCS) for definitive bone defect treatment in limb osteomyelitis. We included adult patients with limb osteomyelitis who received debridement and ALCS insertion into the bone defect as definitive management between 2013 and 2020 in our clinical centre. The follow-up time was at least two years. Data on patients’ demographics, clinical characteristics, and infection recurrence were retrospectively collected and analyzed.Aims
Methods
Gram-negative periprosthetic joint infection (PJI) has been poorly studied despite its rapidly increasing incidence. Treatment with one-stage revision using intra-articular (IA) infusion of antibiotics may offer a reasonable alternative with a distinct advantage of providing a means of delivering the drug in high concentrations. Carbapenems are regarded as the last line of defense against severe Gram-negative or polymicrobial infection. This study presents the results of one-stage revision using intra-articular carbapenem infusion for treating Gram-negative PJI, and analyzes the characteristics of bacteria distribution and drug sensitivity. We retrospectively reviewed 32 patients (22 hips and 11 knees) who underwent single-stage revision combined with IA carbapenem infusion between November 2013 and March 2020. The IA and intravenous (IV) carbapenem infusions were administered for a single Gram-negative infection, and IV vancomycin combined with IA carbapenems and vancomycin was applied for polymicrobial infection including Gram-negative bacteria. The bacterial community distribution, drug sensitivity, infection control rate, functional recovery, and complications were evaluated. Reinfection or death caused by PJI was regarded as a treatment failure.Aims
Methods
Staphylococcus aureus is the most frequently isolated organism in periprosthetic joint infections. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding of its antibacterial characteristics is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against S. aureus. SF samples were collected from patients undergoing total elective knee or hip arthroplasty. Different S. aureus strains previously found to be sensitive and resistant, UAMS-1 and USA300 WT, respectively, were used. We performed in-vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10µM of copper. We determined the minimum
There is a lack of biomaterial-based carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotics for bone infections. RIF is also known for causing rapid development of antibiotic resistance when given as monotherapy. This in vitro study evaluated a clinically used biphasic calcium sulphate/hydroxyapatite (CaS/HA) biomaterial as a carrier for dual delivery of RIF with vancomycin (VAN) or gentamicin (GEN). The CaS/HA composites containing RIF/GEN/VAN, either alone or in combination, were first prepared and their injectability, setting time, and antibiotic elution profiles were assessed. Using a continuous disk diffusion assay, the antibacterial behaviour of the material was tested on both planktonic and biofilm-embedded forms of standard and clinical strains of Aims
Methods
Periprosthetic joint infection (PJI) remains an extremely challenging complication. We have focused on this issue more over the last decade than previously, but there are still many unanswered questions. We now have a workable definition that everyone should align to, but we need to continue to focus on identifying the organisms involved. Surgical strategies are evolving and care is becoming more patient-centred. There are some good studies under way. There are, however, still numerous problems to resolve, and the challenge of PJI remains a major one for the orthopaedic community. This annotation provides some up-to-date thoughts about where we are, and the way forward. There is still scope for plenty of research in this area. Cite this article:
Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models. Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted.Aims
Methods
Aim. Implant infections caused by Staphylococcus aureus are difficult to treat due to biofilm formation, which complicates surgical and antibiotic treatment. Herewith we introduce an alternative approach using monoclonal antibodies (mAbs) targeting S. aureus and provide the biodistribution and specificity in a mouse implant infection model. Methods. 4497-IgG1targeting S. aureus Wall Teichoic Acid was labeled to Indium-111 using “CHXA” as a chelator. SPECT-CT scans were performed at 24, 72 and 120 hours after administration in Balb/cAnNCrl mice with a subcutaneous implant pre-colonized with biofilm of S. aureus. Biodistribution over the various organs of this labelled antibody was visualized and quantified using SPECT-CT imaging and compared to uptake at the target tissue with implant infection. Results. Uptake of the . 111. In-4497 mAbs (half-life 59 hours) at the infected implant gradually increased from 8.34%ID/g at 24 hours to 9.22%ID/g at 120 hours. Uptake at the heart/blood pool decreased over time from 11.60 to 7.58%ID/g whereas the uptake in other organs decreased from 7.26 to less than 4.66%ID/g at 120 hours. Conclusion. 111. In-4497 mAbs was found to specifically detect S. aureus and its biofilm with excellent and prolonged accumulation at the colonized implant site. Therefore, it holds great promise as a drug delivery system for diagnostic and