THE ANTIMICROBIAL PROPERTIES OF EXOGENOUS COPPER IN HUMAN SYNOVIAL FLUID AGAINST STAPHYLOCOCCUS AUREUS: AN IN VITRO STUDY

The Canadian Orthopaedic Association (COA) and Canadian Orthopaedic Research Society (CORS) Annual General Meeting, Quebec City, Quebec, Canada, 8–11 June 2022. Part 1 of 2.



Abstract

Staphylococcus aureus is the most frequently isolated organism in periprosthetic joint infections. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding of its antibacterial characteristics is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against S. aureus.

SF samples were collected from patients undergoing total elective knee or hip arthroplasty. Different S. aureus strains previously found to be sensitive and resistant, UAMS-1 and USA300 WT, respectively, were used. We performed in-vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated the sensitivity to killing, comparing WT and CopAZB-deficient USA300 strains.

UAMS-1 evidenced a greater sensitivity to SF when compared to USA300 WT, at 12 (p=0.001) and 24 hours (p=0.027). UAMS-1 significantly died at 24 hours (p=0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at 4 (p=0.001), 12 (p=0.005) and 24-hours (p=0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at 4 (p=0.011), 12 (p=0.011), and 24 hours (p=0.011). Both WT and CopAZB-deficient USA300 strains significantly died in SF, evidencing a MBC-Cu of 50µM against USA300 WT (p=0.011).

SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. The addition of 10µM of copper was highly toxic for both strains, confirming its bactericidal effect. We evidenced CopAZB-proteins involvement in copper effluxion by demonstrating the high sensitivity of the mutant strain to lower copper concentrations. Thus, we propose CopAZB-proteins as potential targets and the use of exogenous copper as possible treatment alternatives against S. aureus.