Advertisement for orthosearch.org.uk
Results 1 - 20 of 765
Results per page:
Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 132 - 133
1 Mar 2006
Williams R Jones A Evans R Pritchard M Dent C
Full Access

We propose a grading system for contrast free MRI images of tennis elbow and evaluate the inter and intra observer variability of their interpretation. Methods: Three senior orthopaedic surgeons were asked to blindly grade 0.2T dedicated extremity contrast free MRI images of elbows of patients who presented with varying degrees of symptomatic tennis elbow. Our proposed grading system of 1 to 5 based on the pattern around the common extensor tendon was used. Images of the symptomatic and contralateral non symptomatic elbows were graded blindly twice with an interval of 1 month by each surgeon. Each surgeon graded 176 MRI images twice. The grades were subsequently grouped into (I) grades 1 to 2 and (II) grades 3 to 5. Results: With regards to the intra observer agreement, consultant A showed 90.1% agreement, consultant B showed 90.6% agreement and consultant C 96.0% agreement. The mean intra observer agreement rate was 92.2%. The inter observer agreement between consultant A and B was 82.46%, between A and C 67.1% and between B and C 80.1%. It was also noted that there were systematic differences to the inter observer variability. Consultant A graded the images 3 to 5 on both occasions 52.9% of the time, consultant B graded 3 to 5 on both occasions 37.8% of the time and consultant C graded 3 to 5 on both occasions 23.3% of the time. Conclusion: The intra observer agreement rate is high. There is however a greater inter observer variation but this variation is consistent. We suggest that the inter observer differences can be improved by (1) reducing the grades to positive or negative and (2) by group reeducation of the observers


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 6 - 6
1 Apr 2013
Sakagoshi D Sawaguchi T Shima Y Inoue D Oshima T Goldhahn S
Full Access

Introduction. Tip apex distance (TAD) is reported as a predictor for cut outs of lag screws in the treatment of intertrochanteric fractures, and surgeons are adviced to strive for TAD within 20 mm. However the definition of neck axis and the limb position of lateral radiograph are not clearly described in the original literature. We propose the refined TAD by defining these factors. The objective of this study was to analyze the interobserver agreement of this refined TAD. Materials and Method. X rays of 130 cases of unstable trochanteric fractures were used for the analysis of the refined TAD. In the refined TAD, neck axis was defined as the line between the center of femoral head and midpoint of narrowest part of the femoral neck, and lateral radiograph was taken with hip flexion 90 degrees and abduction 45 degrees. The refined TAD was independently measured by 2 experienced (observer 1,2) and 2 inexperienced (observer 3,4) orthopaedic surgeons who were trained with the new method before the measurement. Intraclass correlation coefficient (ICC [2,4]) was calculated to assess the interobserver agreement. Result. The mean refined TADs were 18.2:18.4:18.2:18.2 for observer 1:2:3:4. There was a strong correlation among all four observers (ICC 0.998, (95% CI: 0.998, 0.999). Discussion. Regardless of the clinical experience of observers, the refined TAD is a reliable tool and can be used to develop new TAD recommendations for predicting failure of fixation


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 157 - 157
1 Feb 2003
Hashmi M Rigby A Saleh M
Full Access

To determine the Inter & Intra-observer Agreement in Assessment & Classification of Non-unions of fractures based on Radiological appearance. Medical records and X-rays of patients who attended the Limb Reconstruction Clinic (1987 to 2000) in a University Hospital for fracture non-union were studied. X-rays of one hundred adult patients with established non-union were selected by random sampling. Common denominators of various classification / assessment systems were selected for study. Observers were selected in 3 categories (2 in each): Senior Limb Reconstruction specialist, Consultant Musculoskeletal Radiologists, Senior trainees (Post-FRCS Orth). Data was analysed by calculating kappa coefficients (95% confidence intervals). Kappa measures between observer agreements having been corrected for chance. Radiologists were unable to comment on vascularity. (S= substantial, M= moderate, F= fair & P= poor). It would appear that the agreement for classification of atrophic/hypertrophic non-union is good all round (both inter & intra). Within this classification, radiologists showed better agreement than trainees whose results were better than Orthopaedic specialists. Agreement of healing potential & infection was fair to poor only. Radiographic analysis of non-union remains poor indicating the need for further study to see whether identifiable features exist


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 486 - 486
1 Sep 2009
Kumar N Guo-Xin N Wong H
Full Access

Study Design: A radiographic study using disarticulated cadaver thoracic vertebrae. Objective: To determine the accuracy of orthogonal X-rays in detecting thoracic pedicle screw position by different groups of observers. Summary of Background Data: Pedicle screws are increasingly being used for internal fixation of the thoracic spine. Surgeons and radiologists are often required to make decisions on the pedicle screw position by plain antero-posterior (AP) and lateral radiographs. Materials and Methods: 23 disarticulated fresh adult thoracic vertebrae were used in this study. Pedicle screws were inserted completely within the pedicle; or deliberately violating the lateral or medial cortex of the pedicle. AP and lateral radiographs of each vertebrae were assessed by 2 spine surgeons, 2 spine trainees, and 2 musculoskeletal radiologists in a sequence of AP alone, and AP + lateral views. They were supposed to cataogorize the pedicular screw as ‘out laterally’/‘inside the pedicle’/‘out medially’ or ‘unsure’. Their assessments were compared to the actual position of the screws determined by the axial views. Results: For each screw position, trend was found towards slightly better accuracy with availability of AP & lateral views in combination. From either AP alone or AP + lateral views, significantly higher accuracy was found in detecting screws “out laterally” than “inside pedicle” (p< 0.01), or “out medially”(p< 0.05), respectively. Nearly 30% of screws that were deliberately placed through the medial pedicle wall were not correctly identified. In addition, surgeons have highest accuracy from either AP alone, or AP + lateral views, followed by the spine trainees and radiologists. Radiologists provided more “unsure” answers than surgeons or trainees. Conclusions: Screws that perforated the lateral cortex were the easiest, and those that were wholly within the pedicle were the most difficult to identify correctly. The use of plain radiographs to detect thoracic pedicle screws placed through the critical medial cortex is unreliable. The positions of thoracic pedicle screws appear to be more accurately detected by AP + lateral, however, the major contribution was from AP views. Surgeon experience continues to be vitally important in the safe placement of thoracic pedicle screws. Key points:. Screws that perforated the lateral cortex were the easiest, and those that were wholly within the pedicle were the most difficult to identify correctly. The use of plain radiographs to detect thoracic pedicle screws placed through the critical medial cortex is unreliable. AP + lateral views provides higher accuracy in determining the screw position, while, the major contribution comes from AP views. Surgeon experience, in the use of tactile skills and anatomical knowledge continue to be vitally important in the safe placement of thoracic pedicle screws


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 349 - 349
1 Jul 2008
Higgs ZCJ Danks B Sibinski M Rymaszewski L
Full Access

Over the last 15 years there have been a series of publications reporting the beneficial effects of elbow arthrolysis, with considerable variation in operative technique and post-operative management.

Aim. To assess the results of open elbow arthrolysis in patients who did not receive any physiotherapy after discharge from hospital, although this is routinely prescribed by many surgeons.

Patients and Methods. Prospectively collected data of 34 patients with a minimum follow-up of 1 year after arthrolysis was analysed. All the procedures were performed by the same surgeon, achieving as much improvement in elbow motion as possible at operation. All the patients had continuous brachial plexus blocks and continual passive motion for 2–3 days postoperatively but none received any physiotherapy after discharge. At review, a senior physiotherapist formally assessed all the patients, including measuring elbow motion with a goniometer.

Results. All patients’ arc of movement improved from, with mean elbow flexion increasing by 16 degrees and extension 20 degress at the last follow-up. Upper limb function, assessed with a Disabilities of the Arm, Shoulder and Hand score (DASH), had improved 30%. Pain had decreased from 4.8 to 3.1 using the Visual Analogue Score. The greatest improvement in motion was obtained in the stiffest elbows – 5 patients with an arc of 30 degrees or less pre-operatively achieved an arc of 96 degrees by the time of the last review. Only early complications occurred – ulnar neuritis and significant pain – but these symptoms had largely settled by the time of the last review.

Conclusions. Good results of open arthrolysis for post-traumatic elbow stiffness can be achieved with continuous brachial plexus blocks and continual passive motion for 2–3 days post-operatively. There appears to be little evidence to support formal treatment with physiotherapy after discharge from hospital, as our results are similar to other reported series.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 88 - 88
1 Mar 2012
Higgs Z Danks B Sibinski M Rymaszewski L
Full Access

Aim

Over the last 15 years there has been a series of publications reporting the beneficial effects of elbow arthrolysis, with considerable variation in operative technique and post-operative management. Many advocate the use of passive stretching techniques in the early post-operative period if range of motion fails to improve satisfactorily. The purpose of this study was to assess our results of open elbow arthrolysis in patients who did not receive any passive stretching after discharge from hospital.

Methods

Prospectively collected data of 55 patients with a minimum follow-up of 1 year after arthrolysis were analysed. All procedures were performed by the same surgeon (LR), achieving as much improvement in elbow motion as possible at operation. All patients had continuous brachial plexus blocks and continual passive motion for 2-3 days post-operatively but none received any passive stretching after discharge. At review, a senior physiotherapist (BD) formally assessed all the patients.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 159 - 159
1 Mar 2009
Gruber G Bernhardt G Clar H Wurnig C
Full Access

Background: An acromiohumeral interval narrower than six millimeters has been considered pathologic and strongly indicative for rotator cuff tears by numerous authors. This prospective study was conducted as an assessment of inter- and intraobserver variation in the radiographic measurement of the acromiohumeral interval and its critical value.

Material and Methods: Thirty blinded, standardized anteroposterior shoulder radiographs were independently reviewed by five board certified orthopedic shoulder surgeons. The acromiohumeral distance, from the inferior anterior acromial aspect to the humeral head was measured in millimeters. The five investigators classified each film a second time in random order.

Results: Finally the same 27 radiographs (90%) have been evaluated by five investigators at both examination time points. The results of three investigators showed significant intra-observer variation ranging from 4 to 11 millimeters for the same radiograph. Six investigator pairs showed significant inter-observer variation at both examination time points (p< 0.05). The maximum inter-observer difference for the same radiograph was 11 millimeters (ranging from 1 to 11, SD 0.3 – 4.2).

Conclusion: In view of our results the assessment of the acromiohumeral interval using anteroposterior x-rays does not seem to be a reproducible method of measurement. Further investigations in combination with CT or MRI are necessary to ensure our findings.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 29 - 29
1 Sep 2012
Bajada S Harrison P Mofidi A Richardson J
Full Access

Introduction

Regenerative medicine is a rapidly expanding discipline. However due to a lack of validated outcome measures, clinical trials have been far few. This study aims to assess the validity, inter-observer reliability and intra-observer reproducibility of experimental fracture healing assessment on plain radiographies. This technique involves implantation of mesenchymal stem cell (MSC) seeded constructs on only one side of the fracture after randomisation.

Methods

We examined inter/intraobserver agreement on the area and “bridging length” of callus formed on opposite sides of the fracture. Among 16 orthopaedic surgeons with trauma commitments (8 consultants, 8 registrars) on two separate occasions (average 52 days apart). They independently assessed the radiographs (AP or lateral) of 28 patients with fractures of the tibial or femoral shaft. The fractures chosen included non-unions treated with MSC/constructs and fresh fractures at 4–9 months. For each radiograph the assessor assigned which side (medial or lateral) is there more callus. Chase-corrected agreement using Fleiss kappa was used to compare opinions. Digital analysis software (Image-J) was used to quantify extent/bridging callus and correlate it with surgeons opinion.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 38 - 38
2 May 2024
Buadooh KJ Holmes B Ng A
Full Access

The Revision Hip Complexity Classification (RHCC) was developed by modified Delphi system in 2022 to provide a comprehensive, reproducible framework for the multidisciplinary discussion of complex revision hip surgery. The aim of this study was to assess the validity, intra-relater and inter-relater reliability of the RHCC. Radiographs and clinical vignettes of 20 consecutive patients who had undergone revision of Total Hip Arthroplasty (THA) at our unit during the previous 12-month period were provided to observers. Five observers, comprising 3 revision hip consultants, 1 hip fellow and 1 ST3-8 registrar were familiarised with the RHCC. Each revision THA case was classified on two separate occasions by each observer, with a mean time between assessments of 42.6 days (24–57). Inter-observer reliability was assessed using the Fleiss™ Kappa statistic and percentage agreement. Intra-observer reliability was assessed using the Cohen Kappa statistic. Validity was assessed using percentage agreement and Cohen Kappa comparing observers to the RHCC web-based application result. All observers were blinded to patient notes, operation notes and post-operative radiographs throughout the process. Inter-observer reliability showed fair agreement in both rounds 1 and 2 of the survey (0.296 and 0.353 respectively), with a percentage agreement of 69% and 75%. Inter-observer reliability was highest in H3-type revisions with kappa values of 0.577 and 0.441. Mean intra-observer reliability showed moderate agreement with a kappa value of 0.446 (0.369 to 0.773). Validity percentage agreement was 44% and 39% respectively, with mean kappa values of 0.125 and 0.046 representing only slight agreement. This study demonstrates that classification using the RHCC without utilisation of the web-based application is unsatisfactory, showing low validity and reliability. Reliability was higher for more complex H3-type cases. The use of the RHCC web app is recommended to ensure the accurate and reliable classification of revision THA cases


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 12 - 12
4 Jun 2024
Chapman J Choudhary Z Gupta S Airey G Mason L
Full Access

Introduction. Treatment pathways of 5. th. metatarsal fractures are commonly directed based on fracture classification, with Jones types for example, requiring closer observation and possibly more aggressive management. Primary objective. To investigate the reliability of assessment of subtypes of 5. th. metatarsal fractures by different observers. Methods. Patients were identified from our prospectively collected database. We included all patient referred to our virtual fracture clinic with a suspected or confirmed 5. th. metatarsal fracture. Plain AP radiographs were reviewed by two observers, who were initially trained on the 5. th. metatarsal classification identification. Zones were defined as Zone 1.1, 1.2, 1.3, 2, 3, diaphyseal shaft (DS), distal metaphysis (DM) and head. An inter-observer reliability analysis using Cohen's Kappa coefficient was carried out, and degree of observer agreement described using Landis & Koch's description. All data was analysed using IBM SPSS v.27. Results. 878 patients were identified. The two observers had moderate agreement when identifying fractures in all zones, apart from metatarsal head fractures, which scored substantial agreement (K=.614). Zones 1.1 (K=.582), 2 (K=.536), 3 (K=.601) and DS (K=.544) all tended towards but did not achieve substantial agreement. Whilst DS fractures achieved moderate agreement, there was an apparent difficulty with distal DS, resulting in a lot of cross over with DM (DS 210 vs 109; DM 76 vs 161). Slight agreement with the next highest adjacent zone was found when injuries were thought to be in zones 1.2, 1.3 and 2 (K=0.17, 0.115 and 0.152 respectively). Conclusions. Reliability of sub-categorising 5. th. metatarsal fractures using standardised instructions conveys moderate to substantial agreement in most cases. If the region of the fracture is going to be used in an algorithm to guide a management plan and clinical follow up during a virtual clinic review, defining fractures of zones 1–3 needs careful consideration


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 8 - 8
10 Oct 2023
Leow J Oliver W Bell K Molyneux S Clement N Duckworth A
Full Access

To develop a reliable and effective radiological score to assess the healing of isolated ulnar shaft fractures (IUSF), the Radiographic Union Score for Ulna fractures (RUSU). Initially, 20 patients with radiographs six weeks following a non-operatively managed ulnar shaft fracture were selected and scored by three blinded observers. After intraclass correlation (ICC) analysis, a second group of 54 patients with radiographs six weeks after injury (18 who developed a nonunion and 36 who united) were scored by the same observers. In the initial study, interobserver and intraobserver ICC were 0.89 and 0.93, respectively. In the validation study the interobserver ICC was 0.85. The median score for patients who united was significantly higher than those who developed a nonunion (11 vs 7, p<0.001). A ROC curve demonstrated that a RUSU ≤8 had a sensitivity of 88.9% and specificity of 86.1% in identifying patients at risk of nonunion. Patients with a RUSU ≤8 (n = 21) were more likely to develop a nonunion (n = 16/21) than those with a RUSU ≥9 (n = 2/33; OR 49.6, 95% CI 8.6–284.7). Based on a PPV of 76%, if all patients with a RUSU ≤8 underwent fixation at 6-weeks, the number of procedures needed to avoid one nonunion would be 1.3. The RUSU shows good interobserver and intraobserver reliability and is effective in identifying patients at risk of nonunion six weeks after fracture. This tool requires external validation but may enhance the management of patients with isolated ulnar shaft fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 89 - 89
23 Feb 2023
Marasco S Gieroba T Di Bella C Babazadeh S Van Bavel D
Full Access

Identifying and restoring alignment is a primary aim of total knee arthroplasty (TKA). In the coronal plane, the pre-pathological hip knee angle can be predicted using an arithmetic method (aHKA) by measuring the medial proximal tibial angle (MPTA) and lateral distal femoral angle (aHKA=MPTA - LDFA). The aHKA is shown to be predictive of coronal alignment prior to the onset of osteoarthritis; a useful guide when considering a non-mechanically aligned TKA. The aim of this study is to investigate the intra- and inter-observer accuracy of aHKA measurements on long leg standing radiographs (LLR) and preoperative Mako CT planning scans (CTs). Sixty-eight patients who underwent TKA from 2020–2021 with pre-operative LLR and CTs were included. Three observers (Surgeon, Fellow, Registrar) measured the LDFA and MPTA on LLR and CT independently on three separate occasions, to determine aHKA. Statistical analysis was undertaken with Bland-Altman test and coefficient of repeatability. An average intra-observer measurement error of 3.5° on LLR and 1.73° on CTs for MPTA was detected. Inter-observer errors were 2.74° on LLR and 1.28° on CTs. For LDFA, average intra-observer measurement error was 2.93° on LLR and 2.3° on CTs, with inter-observer errors of 2.31° on LLR and 1.92° on CTs. Average aHKA intra-observer error was 4.8° on LLR and 2.82° on CTs. Inter-observer error of 3.56° for LLR and 2.0° on CTs was measured. The aHKA is reproducible on both LLR and CT. CT measurements are more reproducible both between and within observers. The difference between measurements using LLR and CT is small and hence these two can be considered interchangeable. CT may obviate the need for LLRs and may overcome difficulties associated with positioning, rotation, body habitus and flexion contractures when assessing coronal alignment


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 57 - 57
1 Nov 2022
Prem R West B Jenner E Bolton L Deshmukh S
Full Access

Abstract. Aim. This study aims to Inter and intra observer reliability compare, use of a standard goniometer (SG) to measure intermetacarpal angle (degrees) vs use of a new technique of using a digital vernier calliper (DVC) (mm) to measure the distance between the first and second metacarpal head. Method. Maximal active abduction and extension of both thumbs was measured in 20 healthy volunteers on two occasions at least one week apart by two assessors. Results. The inter and intra-observer agreement was higher & the variance of the data was lower using the DVC with the new technique than the SG for both thumb abduction and extension. Additionally, the correlation between measurement of extension and abduction was higher using the DVC than the SG. Conclusion. Whilst both tools provide acceptable intra and inter-observer agreement, the new technique using a DVC is consistently better and more reliable than a SG in measuring thumb abduction and extension. The study also supports our hypothesis that the thumb rotates around the second metacarpal head with a consistent radius


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_6 | Pages 2 - 2
20 Mar 2023
Brennan C Slevin Z Savaridas T
Full Access

The suprascapular nerve is an ideal target for nerve blockade to alleviate shoulder pain given its widespread innervation to the shoulder girdle. Many techniques have been described. To widen the availability of this treatment we investigate whether an anatomical landmark technique can be easily learned by novice injectors to provide efficacious blockade. Five injectors were recruited with varying experience; from the novice medical student to an orthopaedic consultant. Five torsos (10 shoulders) were used. A single page of written instruction and illustration of the Dangoisse landmark technique was provided prior to injection of a Thiel embalmed cadaver bilaterally. A pre-mixed injectate with blue dye was used. Cadavers were dissected and the presence or absence of dye staining reported by 3 observers and a consensus agreement reached. Dissection demonstrated diffuse staining in the suprascapular fossa. 90% of shoulders were found to have adequate staining of the suprascapular nerve directly, or its distal branches, in a manner which would provide adequate anaesthesia. The inter-observer agreement was good (k = 0.73) for staining at the supraspinous fossa and excellent (k=0.87) for staining distally. The technique was easily performed by novice injectors with a 100% success rate. We demonstrate that this technique is reproducible by a range of clinicians to effectively provide anaesthesia of the SScN. The main risks are ineffective block (10% in this series) and of intravascular injection. Within a resource strained healthcare environment greater uptake of this technique is likely to be of benefit to a wider array of patients


The purpose of this study was to investigate the effectiveness of casting in achieving acceptable radiological parameters for unstable ankle injuries. This retrospective observational cohort study was conducted involving the retrieval of X-rays of all ankles taken over a 2 year period in an urban setting to investigate the radiological outcomes of cast management for unstable ankle fractures using four acceptable parameters measured on a single X- ray at union. The Picture Archiving and Communication System (PACS) was used, the X-rays were measured by a single observer. From the 1st of January 2020 to the 31st of December 2021, a total of 1043 ankle fractures were treated at the three hospitals with a male to female ratio of 1:1.7. Of the 628 unstable ankle injuries, 19% of patients were lost to follow up. 190 were managed conservatively with casts, requiring an average of 4 manipulations, with a malunion rate of 23.2%. Unstable ankle injuries that were treated surgically from the outset and those who failed conservative management and subsequently converted to surgery had a malunion rate of 8.1% and 11.0% respectively. Unstable ankle fractures pose a challenge with a high rate of radiological malunion, regardless of the treatment Casting surgery from the outset or converted to surgery, with rates of 23% and 8% and 11% respectively. In this multivariate analysis we found that conservative management was the only factor influencing the incidence of malunion, age, sex and type of fracture did not have a scientific significant influence


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 132 - 132
11 Apr 2023
van Hoogstraten S Arts J
Full Access

Malalignment is often postulated as the main reason for the high failure rate of total ankle replacements (TARs). Only a few studies have been performed to correlate radiographic TAR malalignment to the clinical outcome, but no consistent trends between TAR alignment parameters and the clinical outcome were found. No standard TAR alignment measurement method is present, so reliable comparison between studies is difficult. Standardizing TAR alignment measurements and increasing measurable parameters on radiographs in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurement on radiographs in the clinic. A tool to semi-automatically measure TAR alignment on anteroposterior and lateral radiographs was developed and used by two observers to measure TAR alignment parameters of ten patients. The Intraclass Coefficient (ICC) was calculated and accuracy was compared to the manual measurement method commonly used in the clinic. The tool showed an accuracy of 76% compared to 71% for the method used during follow-up in the clinic. ICC values were 0.94 (p<0.01) and higher for both inter-and intra-observer reliability. The tool presents an accurate, consistent, and reliable method to measure TAR alignment parameters. Three-dimensional alignment parameters are obtained from two-dimensional radiographs, and as the tool can be applied to any TAR design, it offers a valuable addition in the clinic and for research purposes


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 23 - 23
10 May 2024
Leary J Lynskey T Muller A
Full Access

Objective. Carpal tunnel release surgery is a commonly performed procedure for alleviating symptoms of median nerve compression and restoring hand function. With pressure on theatre time these procedures are now commonly performed in a step-down out-patient facility under local anaesthetic. The choice of suture for skin closure in this procedure can impact the quality of wound healing, patient outcomes and the follow-up required however the question of the best type of suture remains unanswered. The purpose of this study was to compare the outcomes of absorbable and non-absorbable sutures using a randomised control trial design. Methods. Eighty patients diagnosed with bilateral carpal tunnel syndrome were enrolled and underwent outpatient carpal tunnel release surgery under local anaesthetic in a staged fashion. Random number generation was used to assign each hand to receive interrupted nylon or Vicryl Rapide sutures. Pre-operative data collection included patient demographics, ASA, inflammatory conditions, smoking status as well as a Boston Carpal Tunnel Questionnaire (BCTQ) for each hand. Patients were followed up at 2 and 6 weeks after each operation and the BCTQ was repeated along with the Patient and Observer Scar Assessment Scale and the VAS score for wound discomfort. This study has approval from the DHB ethics committee, Local Iwi, HDC and ANZ Clinical Trials:ACTRN12623000100695. Results. Statistical analysis assessed patient preference and the scores between the groups. Multi-variate analysis was performed to assess the factors that may be contributing to patient choice. Conclusion. Insights into patient preference and clinical outcomes associated with absorbable sutures and non-absorbable sutures in the setting of out-patient surgery are discussed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 41 - 41
23 Feb 2023
Bekhit P Saffi M Hong N Hong T
Full Access

Acromial morphology has been implicated as a risk factor for unidirectional posterior shoulder instability. Studies utilising plain film radiographic landmarks have identified an increased risk of posterior shoulder dislocation in patients with higher acromion positioning. The aims of this study were to develop a reproducible method of measuring this relationship on cross sectional imaging and to evaluate acromial morphology in patients with and without unidirectional posterior shoulder instability. We analysed 24 patients with unidirectional posterior instability. These were sex and age matched with 61 patients with unidirectional anterior instability, as well as a control group of 76 patients with no instability. Sagittal T1 weighted MRI sequences were used to measure posterior acromial height relative to the scapular body axis (SBA) and long head of triceps insertion axis (LTI). Two observers measured each method for inter-observer reliability, and the intraclass correlation coefficient (ICC) calculated. LTI method showed good inter-observer reliability with an ICC of 0.79. The SBA method was not reproducible due suboptimal MRI sequences. Mean posterior acromial height was significantly greater in the posterior instability group (14.2mm) compared to the anterior instability group (7.7mm, p=0.0002) as well when compared with the control group (7.0mm, p<0.0001). A threshold of 7.5mm demonstrated a significant increase in the incidence of posterior shoulder instability (RR = 9.4). We conclude that increased posterior acromial height is significantly associated with posterior shoulder instability. This suggests that the acromion has a role as an osseous restraint to posterior shoulder instability


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 30 - 30
1 Dec 2022
Lohre R Lobo A Bois A Pollock J Lapner P Athwal G Goel D
Full Access

Glenoid baseplate orientation in reverse shoulder arthroplasty (RSA) influences clinical outcomes, complications, and failure rates. Novel technologies have been produced to decrease performance heterogeneity of low and high-volume surgeons. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterise glenoid component orientation in an intra-operative scenario. Glenoid baseplates were implanted in eight fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior centre of rotation (COR) offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3D CT scans with digitally reconstructed radiographs (DRRs) by two independent observers. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results. Visual assessment of glenoid baseplate orientation showed “poor” to “fair” correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a clinically relevant, large discrepancy between intra-operative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 19.2 degrees of inclination and 8mm supero-inferior COR offset occurred. Experienced surgeons had greater measurement error than novices for all measured parameters. Intra-operative measurement errors in glenoid placement may reach unacceptable clinical limits. Kinesthetic input during implantation likely improves orientation understanding and has implications for hands-on learning


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 16 - 16
7 Aug 2023
Arthur L Amin A Rahman A Tu SJ Mellon S Murray D
Full Access

Abstract. Introduction. Anecdotal reports suggest some cementless Oxford Unicompartmental Knee Replacements (OUKRs) have painful early subsidence of the tibial component with valgus rotation and/or posterior tilting. The incidence of subsidence and its association with pain is poorly understood. This radiographic study aimed to evaluate the incidence of tibial subsidence and five-year patient reported outcome measures (PROMs) of a cementless OUKR cohort. Methodology. Cementless OUKRs from a high-volume centre with acceptable post-operative and five-year radiographs were included. Subsidence was determined by measuring the angle of the tibial tray/tibial axis angle and distance between the tibial tray axis and fibula head on anteroposterior and lateral radiographs using a custom MATLAB program. Analysis of 5-year PROMs assessed the relationship between subsidence and pain. Radiographs indicating tibial subsidence were validated by two observers. Results. Radiographs of 94 cementless OUKRs were analysed of which five tibial components had subsided (incidence=5%) with an average of 1.92° varus rotation and 2.97° posterior tilt. Subsidence appeared to occur within the first post-operative year with all tibial components fixed securely at 5 years. Two subsiders had moderate pain (ICOAP=20.5,15.9, AKSS Pain=20,45) and lower Oxford Knee Scores (OKS=26,31) compared to the cohort means (ICOAP=3.91, AKSS Pain=45.9, OKS = 43.6). These two subsiders had BMIs greater than 30. Conclusion. This study found 5% of cementless OUKRs in the cohort underwent tibial subsidence. Subsidence with moderate pain occurred in 2% of cases, and pain may be associated with obesity. A larger study is needed to study subsidence in greater detail