We recorded inter- and intra-observer variations in the classification of ankle fractures by the Lauge Hansen and Weber systems. Radiographs of 94 patients were classified independently by four
A study was undertaken to assess the degree of inter-observer error when a panel of
We studied 19 videotaped knee arthroscopies in 19 patients with mild to moderate osteoarthritis (OA) of the knee in order to compare the intraobserver and interobserver reliability and the patterns of disagreement between four orthopaedic surgeons. The classifications of OA of Collins, Outerbridge and the French Society of Arthroscopy were used. Intraobserver and interobserver agreements using kappa measures were 0.42 to 0.66 and 0.43 to 0.49, respectively. Only 6% to 8% of paired intraobserver classifications differed by more than one category. Observer-specific disagreement was evident both within and between
Aims. Taper corrosion has been widely reported to be problematic for modular total hip arthroplasty implants. A simple and systematic method to evaluate taper damage with sufficient resolution is needed. We introduce a semiquantitative grading system for modular femoral tapers to characterize taper corrosion damage. Methods. After examining a unique collection of retrieved cobalt-chromium (CoCr) taper sleeves (n = 465) using the widely-used Goldberg system, we developed an expanded six-point visual grading system intended to characterize the severity, visible material loss, and absence of direct component contact due to corrosion. Female taper sleeve damage was evaluated by three blinded
Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Methods. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six
Aims. The evidence demonstrating the superiority of early MRI has led to increased use of MRI in clinical pathways for acute wrist trauma. The aim of this study was to describe the radiological characteristics and the inter-observer reliability of a new MRI based classification system for scaphoid injuries in a consecutive series of patients. Methods. We identified 80 consecutive patients with acute scaphoid injuries at one centre who had presented within four weeks of injury. The radiographs and MRI scans were assessed by four
Aims. Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Methods. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The
Aims. Various radiological parameters are used to evaluate a flatfoot
deformity and their measurements may differ. The aims of this study
were to answer the following questions: 1) Which of the 11 parameters
have the best inter- and intraobserver reliability in a standardized
radiological setting? 2) Are pre- and postoperative assessments
equally reliable? 3) What are the identifiable sources of variation?. Patients and Methods. Measurements of the 11 parameters were recorded on anteroposterior
and lateral weight-bearing radiographs of 38 feet before and after
surgery for flatfoot, by three
Aims. Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method. Methods. This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior
Aims. Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Methods. Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three
Objectives. The determination of the volumetric polyethylene wear on explanted material requires complicated equipment, which is not available in many research institutions. Our aim in this study was to present and validate a method that only requires a set of polyetheretherketone balls and a laboratory balance to determine wear. Methods. The insert to be measured was placed on a balance, and a ball of the appropriate diameter was inserted. The cavity remaining between the ball and insert caused by wear was filled with contrast medium and the weight of the contrast medium was recorded. The volume was calculated from the known density of the liquid. The precision, inter- and intraobserver reliability, were determined by four investigators on four days using nine inserts with specified wear (0.094 ml to 1.626 ml), and the intra-class correlation coefficient was calculated. The feasibility of using this method in routine clinical practice and the time required for measurement were tested on 84 explanted inserts by one investigator. Results. In order to get the mean for all investigators and determinations, the deviation between the measured and specified wear was -0.08 ml . (sd. 0.12; -0.21 to 0.11). The interobserver reliability was 0.989 ml (95% confidence interval (CI) 0.964 to 0.997) and the intraobserver reliability was 0.941 for
Aims. The primary aim of this study was to develop a reliable, effective radiological score to assess the healing of humeral shaft fractures, the Radiographic Union Score for HUmeral fractures (RUSHU). The secondary aim was to assess whether the six-week RUSHU was predictive of nonunion at six months after the injury. Patients and Methods. Initially, 20 patients with radiographs six weeks following a humeral shaft fracture were selected at random from a trauma database and scored by three
Aims. The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively. Methods. A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three
Aims. Some patients presenting with hip pain and instability and underlying acetabular dysplasia (AD) do not experience resolution of symptoms after surgical management. Hip-spine syndrome is a possible underlying cause. We hypothesized that there is a higher frequency of radiological spine anomalies in patients with AD. We also assessed the relationship between radiological severity of AD and frequency of spine anomalies. Methods. In a retrospective analysis of registry data, 122 hips in 122 patients who presented with hip pain and and a final diagnosis of AD were studied. Two
Assessment of skeletal age is important in children’s
orthopaedics. We compared two simplified methods used in the assessment
of skeletal age. Both methods have been described previously with
one based on the appearance of the epiphysis at the olecranon and
the other on the digital epiphyses. We also investigated the influence
of assessor experience on applying these two methods. Our investigation was based on the anteroposterior left hand
and lateral elbow radiographs of 44 boys (mean: 14.4; 12.4 to 16.1
) and 78 girls (mean: 13.0; 11.1 to14.9) obtained during the pubertal
growth spurt. A total of nine
Aims. Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Methods. Three
Aims. The primary aim of this study was to compare the postoperative systemic inflammatory response in conventional jig-based total knee arthroplasty (conventional TKA) versus robotic-arm assisted total knee arthroplasty (robotic TKA). Secondary aims were to compare the macroscopic soft tissue injury, femoral and tibial bone trauma, localized thermal response, and the accuracy of component positioning between the two treatment groups. Methods. This prospective randomized controlled trial included 30 patients with osteoarthritis of the knee undergoing conventional TKA versus robotic TKA. Predefined serum markers of inflammation and localized knee temperature were collected preoperatively and postoperatively at six hours, day 1, day 2, day 7, and day 28 following TKA. Blinded
Aims. The Oswestry-Bristol Classification (OBC) was recently described as an MRI-based classification tool for the femoral trochlear. The authors demonstrated better inter- and intraobserver agreement compared to the Dejour classification. As the OBC could potentially provide a very useful MRI-based grading system for trochlear dysplasia, it was the aim to determine the inter- and intraobserver reliability of the classification system from the perspective of the non-founder. Methods. Two orthopaedic surgeons independently assessed 50 MRI scans for trochlear dysplasia and classified each according to the OBC. Both
Aims. The Wrightington classification system of fracture-dislocations of the elbow divides these injuries into six subtypes depending on the involvement of the coronoid and the radial head. The aim of this study was to assess the reliability and reproducibility of this classification system. Methods. This was a blinded study using radiographs and CT scans of 48 consecutive patients managed according to the Wrightington classification system between 2010 and 2018. Four trauma and orthopaedic consultants, two post CCT fellows, and one speciality registrar based in the UK classified the injuries. The seven