Health care is best delivered face to face, doctor to patient. However, in some places like Scotland, patients can be in remote areas, far from the nearest health care provider. Medical video conferencing (VC) enables patients and doctors to meet for consultations from wherever they may be without the need for travel, and is already used widely in countries like Australia and Canada. To do a pilot study of using the existing VC facility at our hospital for surgical pre-assessment of patients for elective foot/ankle and lower limb arthroplasty surgery. Methods- A prospective pilot study was performed at our hospital after approval from our ethics committee. Patient-records were vetted to include/exclude from the study and cases considered as “straightforward” were included. Two separate rooms with VC facility were set up in the orthopaedic outpatients, one with the patient and a trained physiotherapist, while the surgeon used the second room to discuss patient's complaints, do a physical examination, and discuss surgery where appropriate.Background-
Aim-
Isolated Weber B lateral malleolus fractures heal uneventfully, but concern that late subluxation may occur due to unrecognised medial ligament tearing, despite an intact mortice on initial radiographs, often results in overtreatment. The aim of this study was to determine the incidence of late talar shift with nonoperative management in a cohort of patients with no initial talar shift, and also record functional outcomes at 16–28 months following injury. This was a retrospective review of 129 patients with Weber B lateral malleolar fractures initially referred to the fracture clinic between October 2011 and October 2012. Eight had obvious talar shift and therefore underwent surgery, with the remaining 121 treated in plaster (n=41), a Velcro boot (n=70) or bandage (n=10). No stress x-rays or MRI scans were performed. Weight-bearing was permitted as pain allowed. Radiographs taken on discharge from the clinic were reviewed to assess talar shift. Functional outcomes assessment was carried out using Manchester Oxford Foot Questionnaire and Olerud-Molander score.Introduction:
Methods:
We compared the postoperative wound discharge rates and 3 months clinical results of three types of wound closure and dressing – 2-octylcyanoacrylate with Opstie (G+O), 2-octylcyanoacrylate with Tegaderm (G+T), and Opsite without 2-octylcyanoacrylate (O) in patients having primary total hip arthroplasty. We randomised 141 patients scheduled for primary total hip arthroplasty into 3 arms of this study- G+O, G+T, or O. The extent of wound discharge was recorded on a diagrammatic representation of the dressing in situ on paper and graded each day. Dressings were left in-situ provided the extent of wound discharge allowed for this. The patient was clinically reviewed at 3 months to assess their scar length, cosmesis, scar discomfort, and evidence of superficial or deep wound sepsis. A greater number of patients dressings remained dry on day 1 postoperatively in the two groups with 2-octylcyanoacrylate compared to the no glue group In patients who have had primary total hip arthroplasty, usage of 2-octylcyanoacrylate for wound closure along with Tegaderm dressing reduces wound discharge. The same effect is not noted in glue with Opsite group. Whilst dressing changes required in the non-glue group compared from the two glue groups did not reach statistical significance, this may have clinical relevance for patients and nursing staff. No effect on postoperative length of stay, or wound complications was noted.
A consensus regarding management of calcaneal fractures eludes orthopaedic surgeons. While operative treatment has gained more acceptance, surgical morbidity remains high. We undertook a retrospective review of early complications and radiological outcomes following internal fixation of calcaneal fractures in our unit over 15 months. A consecutive series of 33 patients who underwent fixation of the Calcaneus was selected. Patient records, X-rays and scans were reviewed. 37 fractures in 33 patients underwent fixation. 81 % were male. Mean age at surgery was 37yrs (19 -59yrs). 35 % were operated within 1 wk of injury and 13% after 2 wks of injury. 43% were Sanders' type III, 18% type II and 13% tuberosity avulsion fractures. 63% had a reversed/zero Bohler's angle. Mean post-op Bohler's angle was 32 degrees. Overall complication rate was 32%, with a combined deep infection rate of 8%. All patients with infection were male, and 70% were smokers. 86% were above 40yrs of age (mean 47yrs). The deep infection rate for intra-articular fractures was 3% and for tuberosity avulsion fractures 40%. Majority of patients with wound complications had been operated within 7 days of injury. Males over 40yrs and smokers seem to be at most risk of wound complications. Time to surgery/delay in surgery up to 2 wks did not seem to have any adverse consequences. Complications increase with fracture complexity and avulsion fractures have highest risk of wound breakdown. Near anatomical restoration of the articular surface is possible in most.
The patients were divided into two groups, A and B. The first, Group A, in which only Dynesys was used and the second, Group B, in which Dynesys was used adjacent to one or more fused segments.
The ROM of the end plate angle at the instrumented segments in Group A reduced from 5.72o to 1.44o{difference 4.28o(p=0.005)} and in Group B reduced from 6.00o to 2.17o,{difference 3.83o(p=0.001)}. The ROM of the end plate angle at the level above instrumentation in Group A reduced from 8.2o to 5.1o {reduction 3.1o(p=0.085)}, while in group-B increased from 7.3o to 7.5o, a difference of 0.2o (p=0.877). The mean anterior disc height in Group A reduced by 2.1mm (p<
0.001) from 9.59mm to 7.44mm. The posterior disc height also reduced from 6.56mm to 6.26mm, a difference of 0.3mm, (p=0.434). In Group B, the anterior disc height reduced by 1.98mm (pre-op=9.04mm, post-op= 7.06mm, p=0.001) and the posterior height by 0.35mm (pre-op 6.14mm to post op 5.79mm, p=0.443)
At 6 months, there was a significant increase in the spinal canal and foraminal dimension. However at 2 years there was a reduction in these dimensions such that there was no significant difference from the preop-erative measurements.
The patients were divided into two groups, A and B. The first, Group A, in which only Dynesys was used and the second, Group B, in which Dynesys was used adjacent to one or more fused segments.
The ROM of the end plate angle at the instrumented segments in Group A reduced from 5.72o to 1.44o{difference 4.28o(p=0.005)} and in Group B reduced from 6.00o to 2.17o,{difference 3.83o(p=0.001)}. The ROM of the end plate angle at the level above instrumentation in Group A reduced from 8.2o to 5.1o {reduction 3.1o(p=0.085)}, while in group-B increased from 7.3o to 7.5o, a difference of 0.2o (p=0.877). The mean anterior disc height in Group A reduced by 2.1mm (p<
0.001) from 9.59mm to 7.44mm. The posterior disc height also reduced from 6.56mm to 6.26mm, a difference of 0.3mm, (p=0.434). In Group B, the anterior disc height reduced by 1.98mm (pre-op=9.04mm, post-op= 7.06mm, p=0.001) and the posterior height by 0.35mm (pre-op 6.14mm to post op 5.79mm, p=0.443)
The ZCQ, ODI, SF-36 and VAS were completed preoperatively and at 12 months by 54, 50, 52, 52 respectively. Thirty-nine patients completed all questionnaires at all time points and the maximal clinical efficacy was evident 3 months post-operatively. Clinical significant improvement was maintained at the 6- and 12 month post-operative follow-ups despite a minimal loss of clinical efficacy in absolute mean values. Overall, clinically significant response was achieved in 65%. Seventy-one per cent of double level patients and 61% of single level patients as determined by the ZCQ, had a clinically significant response. Corresponding changes were seen in VAS and ODI and SF-36. Ten patients (18%) required caudal epidural for recurrence of symptoms and 1 patient required perifacet injections for back pain.
Thirty patients with were treated with Dynesys system. All had discography and positional MRI preoperatively and nine months post-operatively. The patients were divided in to two groups. The first in which only Dynesys was used and the second in which Dynesys was used with fusion.
The ROM of the end plate angle at the instrumented segments in group-A reduced from 5.24o to 2.18o{difference 3.06o(p<
0.005)} and in group-B reduced from 6.69o to 2.46o,{difference 4.23o(p=0.008)}. The ROM of the end plate angle at adjacent level in group-A changed from 8.26o to 7.0o {reduction 1.26o(p=0.388)},while in group-B increased from 6.91o to 8.64o, {difference 1.73o(p=0.149)} The mean anterior disc height in-group A reduced by 1.43mm (p<
0.005) from 9.75mm to 8.32mm, and the posterior one was increased from 6.27mm to 6.77mm {difference of 0.5mm,(p=0.008)}. In group-B the anterior disc height reduced by 1.11mm (pre-op=10.44mm,post-op= 9.33mm,p=0.049) and the posterior one by 0.16mm (pre-op 6.98mm to post-op 6.82mm,p=0.714).
Images were taken in sitting flexed, extended, neutral, and standing. The total range of motion of the lumbar spine and of the individual segments were measured, along with changes in disc height, areas of the exit foramina, and dural sac. The mean area of the dural sac at the operated levels increased from 62.46mm2 to 77.69mm2 (p=0.004) in the standing posture and from 70.85mm2 to 94.62mm2 (p=0.019) in extension postoperatively. The area of the exit foramina in extension increased from 83.57mm2 to 107.88mm2 (p=0.002) on the left side and from 83.77mm2 to 108.69mm2 (p=0.012) on the right. The overall changes in the range of movement of the individual segments or of the lumbar spine were statistically insignificant.
The patients were divided into two groups. The Group-A with 14 patients in which only Dynesys was used and Group-B with 11 patients in which Dynesys was combined with fused levels. The operated levels were 51, 13 of which were fused. The results showed that the mean range of movement of the lumbosacral angle reduced by 10.28° (Preop=39.21°, Postop=28.93°) (p=0.016) in group-A. In group-B it reduced by 13.73° (Preop=36.18°, Postop=22.45°) (p=0.02). The range of movement of the end plate angle at the instrumented segments in group-A reduced by 2.96° (Preop=5.56°, Postop=2.60°) (p=0.016) while in group-Bit reduced by 4.23° (Preop=6.69°, Postop=2.46°)(p=0.008). The mean range of movement of the end plate angle at adjacent level in group-A reduced by 1.58° (Preop=8.7°, Postop=7.21°)(p=0.427) while in group-B it increased by 1.73° (Preop=6.91°, Postop=8.64°) (p=0.149) The mean anterior disc height in group-A reduced by 1.18mm (Preop=10.05mm, Postop=8.87mm) (p<
0.005), and the posterior one was increased by 0.6mm (Preop=6.51mm, Postop=8.87mm) (p=0.013). In group-B, the anterior disc height was reduced by 1.11mm (Preop= 10.44mm, Postop=9.33mm) (p=0.049) and the posterior one by 0.16mm (Preop=6.98mm Postop=6.82mm) (p=0.714)
This study measures the changes in the lumbar spine in different postures, pre- and after insertion of the device.
All had a positional MRI preoperatively and nine months post-operatively in flexion-extension-lateral bending. The patients were divided in to two groups: Group(A) with 8 patients in which Dynesys was used with fusion (disc-height<
40 %) Group(B) with 12 patients was the Dynesys-only group (disc-height=40–90%).
The changes in the anterior disc height was (mean= −1.18)(p<
0.05) and to the posterior (mean=0.37)(p=0.134). In bending were (mean=−0.87°)(p=0.18) for left and (mean=−0.24°)(p=0.75) for the right
21 patients (11 males; 10 females) were included in the study. Age ranged from 57 – 88 years. All had symptomatic lumbar spinal stenosis- single level- 13 (L2/3-1; L3/4-3; L4/5-9); double level 8(L3/4, L4/5 – 7; L4/5, L5/ S1 – 1).
This study measures the changes in the lumbar spine in different postures, pre- and after insertion of the device. Methods In our study 25 patients with dominant low back pain, with or without leg pain, were treated with Dynesys system, 14 females and 11 males with mean age 43.5 yrs. Discography was done to evaluate the symptomatic painful level. All patients had a positional magnetic resonance imaging (pMRI) scans preoperatively and nine months post-operatively in standing; sitting flexion and extension, and left and right bending postures. The patients were initially divided into two groups. The first (Group A) with 14 patients in which only Dynesys was used (disc height 40–90%) and the second (group B) with 11 patients in which Dynesys was used with fusion (disc height <
40 %).
The range of movement of the end plate angle at the instrumented segments in group A reduced from 5.6° preoperatively to 2.6° with a difference of 3.0° (p=0.016) while in group B it reduced from 6.7° to 2.5° postoperatively with a difference of 4.2°(p=0.008). The range of movement of the end plate angle at adjacent level in group A changed from 8.8° preop. to 7.2° with a reduction of 1.6° (p=0.427) while in group B it increased from 6.9° to 8.6°, difference of 1.7° (p=0.149) The mean anterior disc height in group A reduced by 1.2mm (p<
0.005) from 10.1mm to 8.9mm postoperatively, and the posterior one was increased from 6.5mm to 8.9mm with a difference of 0.6mm (p= 0.013). In group B the anterior disc height was reduced by 1.1mm (pre-op 10.4mm to post-op 9.3mm; p=0.049) and the posterior one by 0.16mm (pre-op 6.98mm to post-op 6.82mm; p=0.714)