Introduction. Persistent patellofemoral (PF) pain is a common postoperative complication after total knee arthroplasty (TKA). In the USA, patella resurfacing is conducted in more than 80% of primary TKAs [1], and is, therefore, an important factor during surgery. Studies have revealed that the position of the
Introduction:. The widespread use of TKA promoted studies on kinematics after TKA, particularly of the femorotibial joint. Knee joint kinematics after TKA, including the range of motion (ROM) and the physical performance, are also influenced by the biomechanical properties of the patella. Surgeons sometimes report complications after TKA involvinganterior knee pain, patellofemoral impingement and instability. However, only few studies have focused specially on the patella. Because the patella bone is small and overlapped with the femoral component on scan images. In addition, the
Aims: The aim of the study was to determine the efþcacy of jet lavage in comparison to syringe lavage with respect to cement penetration and stability of the poly-ethylene
Purpose: Patellar complications are among the most frequent after total knee arthroplasty. Encasing the patellar piece is one way of resisting the shear forces leading to loosening. Material and Methods: We studied at more than five years the results obtained with a total knee prosthesis implanted with preservation of the posterior cruciate ligament (PCL). This prosthesis has an asymmetric encased patellar insert with a cemented central pivot. The instrumentation ensures patellar thickness. We reviewed 104 implants at more than five years. Six had been lost to follow-up. Ninety-eight implants were still in place. Results: The following complications were observed: four fractures of the upper rim with little displacement (these fractures healed and pain regressed but the insert had moved); three vertical patellar fractures with little displacement (these fractures healed; two were symptomatic temporarily); one transverse fracture of the upper pole with displacement causing a defect in active extension; eight moderate asymptomatic impactions which were visible on the lateral x-ray (modified orientation of the insert with cement fracture). There was no significant difference for functional results (pain 40.9; movement 21.9; knee score 84.3) between patients with or without a patellar complication. Discussion: Insertion of an asymmetric prosthesis increased the risk of an orientation error (two cases early in our experience). Encasing the patellar insert limits medialisation yet the centering was satisfactory (centred patella 95.2%, shift 3.6%, subluxation 1.2%). Encasing provides a peripheral wall protecting against transverse sheer forces. The lateral wall did not fracture, demonstrating its efficacy. The upper wall can fracture under the force of flexion without functional consequences. The other fractures, favoured by section of the lateral patellar wing (p<
0.05), were not treated. Moderate but certain impaction was noted in eight cases at a mean 3.5 years (1–6 years). It was due to failure of bony support under the effect of the compression forces applied on a small surface. The diameter of the encased patellar inserts was rarely more than 25 mm. Once the prosthesis is in place, the periphery of the patella is the only component articulating with the trochlea and its impaction does not cause further aggravation. This contact did not lead to pain in any patients. Conclusions: Complications observed with encased
Purpose: Patellar complications are among the most frequent after total knee arthroplasty. Encasing the patellar piece is one way of resisting the shear forces leading to loosening. Material and methods: We studied at more than five years the results obtained with a total knee prosthesis implanted with preservation of the posterior cruciate ligament (PCL). This prosthesis has an asymmetric encased patellar insert with a cemented central pivot. The instrumentation ensures patellar thickness. We reviewed 104 implants at more than five years. Six had been lost to follow-up. Ninety-eight implants were still in place. Results: The following complications were observed: four fractures of the upper rim with little displacement (these fractures healed and pain regressed but the insert had moved); three vertical patellar fractures with little displacement (these fractures healed; two were symptomatic temporarily); one transverse fracture of the upper pole with displacement causing a defect in active extension; eight moderate asymptomatic impactions which were visible on the lateral x-ray (modified orientation of the insert with cement fracture). There was no significant difference for functional results (pain 40.9; movement 21.9; knee score 84.3) between patients with or without a patellar complication. Discussion: Insertion of an asymmetric prosthesis increased the risk of an orientation error (two cases early in our experience). Encasing the patellar insert limits medialisation yet the centering was satisfactory (centred patella 95.2%, shift 3.6%, subluxation 1.2%). Encasing provides a peripheral wall protecting against transverse sheer forces. The lateral wall did not fracture, demonstrating its efficacy. The upper wall can fracture under the force of flexion without functional consequences. The other fractures, favoured by section of the lateral patellar wing (p<
0.05), were not treated. Moderate but certain impaction was noted in eight cases at a mean 3.5 years (1–6 years). It was due to failure of bony support under the effect of the compression forces applied on a small surface. The diameter of the encased patellar inserts was rarely more than 25 mm. Once the prosthesis is in place, the periphery of the patella is the only component articulating with the trochlea and its impaction does not cause further aggravation. This contact did not lead to pain in any patients. Conclusions: Complications observed with encased
Abstract. Patellofemoral Arthroplasty (PFA) is an alternative to TKA for patellofemoral osteoarthritis that preserves tibiofemoral compartments. It is unknown how implant positioning affects biomechanics, especially regarding the patella. This study analysed biomechanical effects of femoral and
Abstract. Objectives. Patella resurfacing in primary total knee arthroplasty (TKA) remains a contentious issue. Australian rates of patellar resurfacing are 66.6%, significantly higher compared to UK rates of 8–15% and Swedish rates of 2%. Resurfacing has gained popularity in Australia since registry data has shown decreased revision rates with no increase in
Introduction. We have been re-evaluating patellofemoral alignment after total knee arthroplasty (TKA) by using a weight- bearing axial radiographic view after detecting patellar maltracking (lateral tilt > 5° or lateral subluxation > 5 mm) on standard non-weight-bearing axial radiographs. However, it is unclear whether the
Complications of the patellofemoral (PF) joint remain a common cause for revision of total knee replacements. PF complications, such as patellar maltracking, subluxation, dislocation and implant failure, have been linked to femoral and
INTRODUCTION. Wear and fracture of
Introduction. A large number of total knee arthroplasty (TKA) patients, particularly in Japan, India and the Middle East, exhibit anatomy with substantial proximal tibial torsion. Alignment of the tibial components with the standard anterior-posterior (A-P) axis of the tibia can result in excessive external rotation of the tibial components with respect to femoral component alignment. This in turn influences patellofemoral (PF) mechanics and forces required by the extensor mechanism. The purpose of the current study was to determine if a rotating-platform (RP) TKA design with an anatomic
Many recent knee prostheses are designed aiming to the physiological knee kinematics on tibiofemoral joint, which means the femoral rollback and medial pivot motion. However, there have been few studies how to design a
Introduction. Uncemented highly porous titanium implants have been shown to promote osseointegration, and may result in a durable construct for total knee arthroplasty (TKA). Given the mixed results of uncemented TKA, it is important to evaluate the early stability for this product. The objective of the following study was to use radiostereometric analysis (RSA) to assess early fixation of a highly porous tibial baseplate and metal backed patella. Methods. Twenty-seven patients (mean age 64 years, 30% female) undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate, a metal backed patella and tantalum RSA bone markers. Implant migration was assessed using model-based RSA at 1.5, 3, 6, 12 and 24 months post-operative. Patient reported outcome measures were captured using the same follow-up schedule, and compared to pre-operative measures. Results. There were no adverse events affecting implant fixation, and no revisions. Patient function significantly improved by 3 months post-operation (p < 0.001). The highest rate of tibia and patellar component migration occurred over the first six post-operative weeks, with minimal migration thereafter. Mean maximum total point motion (MTPM) at 24 months was 0.72 (SD 0.34) mm for the tibia, and 0.44 (SD 0.25) mm for the patella. Three tibia baseplates migrated more than 1 standard deviation greater than the mean at 24 months, and also had continuous migration (> 0.2mm of MTPM) in the second post-operative year. One
Introduction A biomechanical model was developed to measure wear of all-polyethylene
INTRODUCTION: Following Total Knee Arthroplasties, patellofemoral complications have shown to be responsible for approximately 50% of re-operations. Contemporary patellar designs employ both “onlay” and “inset” configurations. The latter promotes ease of placement, reduced bone removal and a heralded theoretic advantage of increased strength at the fixation interface. However, to date, no reports have compared the disassociation strengths of these two
Purpose. Measurements of patellar kinematics are essential to investigate the link between anterior knee pain following knee arthroplasty and patellar maltracking. A major challenge in studying the patellofemoral (PF) joint postoperatively is that the
Introduction/Aim. Outcomes for guided motion primary total knee arthroplasty (TKA) in obese patients are unknown. Materials and Methods. 1,684 consecutive patients underwent 2,059 primary TKAs with a second-generation guided motion implant (Journey II Bi-Cruciate Stabilized Knee System, Smith & Nephew, Inc., Memphis) between 2011–2017 at three European and seven US sites. Results. Of 2,003 (97.3%) TKAs in 1,644 patients with BMI data: average age 64.5 years; 58.4% females; average BMI 32.5 kg/m. 2. ;13.4% had BMI ≥ 40 kg/m. 2. Subjects with BMI ≥ 40 kg/m. 2. had longest length of hospital stay (LOS) at European sites; LOS similar at US sites. Subjects with BMI ≥ 40 kg/m. 2. (P=0.0349) had longest surgery duration. BMI ≥ 40 kg/m. 2. had more re-hospitalizations or post-TKA reoperations than BMI < 40 kg/m. 2. (12.7% and 9.2% at five-year post-TKA, P<.0495). 62 TKAs were revised (3.39/100 TKA at five years) with no differences in revision risk between groups. 17 (27.4%) revisions involved femoral or tibial component removal; 45 (72.6%) involved tibial insert or
Introduction. Patellar tracking in total knee replacements has been extensively studied, but little is known about patellar tracking in isolated patellofemoral replacements. We compared patellar tracking and the position of the patellar groove in the natural knee, followed by implantation of the femoral component of a PFR (patella unresurfaced) and after implantation of the femoral &
Introduction: Patellar complications after total knee arthroplasty (TKA) remain a common reason for failure. Fully congruent
Total knee arthroplasty (TKA) is a successful operation associated with a high rate of clinical success and long-term durability. Cementless technology for TKA was first explored 30 years ago with the hope of simplifying the performance of the procedure and reducing an interface for potential failure by eliminating the use of cement. Poor implant design and the use of first generation biomaterials have been implicated in many early failures of these prostheses due to aseptic loosening and reflected the failure of either the tibial or