Aims. Wear is difficult to predict in mixed lubricated articulating surfaces and the time of computation is one of the challenges due to the deterministic definition of
Introduction. Large-scale retrieval studies have shown backside wear in tibial inserts is dependent on the surface
Introduction. In Total Knee Arthroplasty (TKA) a proper choice of the implant size is mandatory in order to guarantee the success of the prosthesis, although the tribological behavior TKA is strongly influenced by the implant design. Retrieval analysis of failed total knee prosthesis is essential to investigate the wear mechanism leading to osteolysis and loosening of the implant. Assessments from retrieval studies constitute crucial information in the effort to improve prosthesis functionality and reduce the risk of revision. The aim of the present study was to investigate the correlation among different implant sizes of retrieved TKA and patients' variables such as Body Mass Index (BMI) in terms of surface modifications and morphology change, in order to examine prosthesis properties and performances. In particular, this study can improve the understanding of the tribological behavior of total knee prosthesis and it can help the surgeon to select the best implant size of TKA considering patient's variables. Methods. Twelve retrieved total knee prostheses of the same design but with different sizes were investigated. These prostheses were all cemented, fixed and posterior stabilized. These prostheses were explanted from 12 patients after a mean of 3.2 years (from 1.1 to 7.4 years). These patients had undergone a primary TKA at our hospital between 2005 and 2010; there were 10 women and 2 men with a mean age of 68 years (ranging from 48 to 77 years) at implantation. A qualitative assessment of wear patterns and surface damages was performed on femoral components and polyethylene inserts.
Introduction. The corrosion of modular taper junctions in hip implants is becoming an area of increased research focus. Many design factors have been hypothesized to contribute to this kind of corrosion. The authors' previous research indicated femoral stem taper
Introduction. Implant contamination prior to cement application has the potential to affect the cement-implant bond. the consequences of implant contamination were investigated in vitro using static shear loading with bone cement and titanium dowels of differing surface
Introduction. Recent clinical studies found no apparent reduction in wear using yttria-stabilized zirconia (Y-TZP) instead of cobalt chromium alloy femoral heads bearing against cross-linked UHMWPE. The purpose of this study was to compare the surface topography of retrieved Y-TZP and magnesia-stabilized zirconia (Mg-PSZ) femoral heads and evaluate the influence of time in vivo. The increase in average
Introduction. Wear-related osteolysis continues to be a concern in the long-term outcome and survivorship of total hip arthroplasty (THA) and there continues to be an emphasis on bearing materials that exhibit improved wear profiles. Oxidized zirconium metal (Oxinium®, Smith & Nephew) was developed to reduce the amount of polyethylene wear as compared to cobalt chromium femoral heads, without the risk of brittle fracture seen with older generation ceramics. There are a limited number of retrieval studies evaluating the performance of Oxinium in THA. The aims of this study were 1) to visually assess damage on the surface of a large number of retrieved Oxinium femoral heads, 2) to measure surface
In total hip arthroplasty (THA), aseptic loosening induced by polyethylene (PE) wear debris is the most important cause that limits the longevity of implants. Abrasive wear generated through the mechanism such that micrometer-roughened regions and small asperities on the metallic femoral heads surface locally plow through the PE cup surface. Abrasive wear results in the PE material being removed from the track traced by the asperity during the motion of the metallic femoral heads surface. For the purpose of reducing wear, alumina ceramics was introduced in Europe and Japan in 1970s. The clinical results of ceramic-on-PE bearings regarding the wear resistance have been superior to that of the metal-on-PE bearings. Compared with Co–Cr–Mo alloys, alumina ceramics is advantageous for precision machining because of its higher hardness, enable to form spherical and smooth surface. The fracture resistance of the alumina ceramics itself is related to grain size; the grain size reduction leads to the improvement of its resistance. In this study, we evaluated the roundness and the
Aseptic loosening induced by wear debris of polyethylene (PE) is the most common cause of long-term total hip arthroplasty failure. In the previous studies, we reported that the protruding contour and surface morphology of metallic femoral head brought an increase of PE wear. Alumina ceramics is advantageous (neutral shape and smooth surface) for precision machining compared with metal materials, because hardness of ceramics is higher than that of metal materials. In this study, we measured the roundness and the
Introduction. The initial mechanical stability of cementless femoral stems in total hip arthroplasty is an important factor for stable biological fixation. Conversely, insufficient initial stability can lead to stem subsidence, and excessive subsidence can result in periprosthetic femoral fracture due to hoop stress. The surface
Aims:. To test the effect of different surface
Introduction. In this study, we aimed to investigate the effect of the topography of the female taper surface on taper wear. Patients/Materials & Methods. We measured volumetric material loss at the female taper surface of the first consecutive 36mm MoM hips received at our centre. The MoM hips were from a single manufacturer and possessed matching: head size (36mm); taper geometry (5.65 degree 12 14 tapers); and metallurgy (cobalt chrome female taper mated with a titanium stem). Volume loss was measured with a coordinate measuring machine using validated methods. Surface
Introduction. Implant-cement debonding at the knee has been reported previously [1]. The strength of the mechanical interlock of bone cement on to an implant surface can be associated with both bone cement and implant related factors. In addition to implant surface profile, sub-optimal mixing temperatures and waiting times prior to cement application may weaken the strength of the interlock. Aims. The study aimed to investigate the influence of bone cement related factors such as mixing temperature, viscosity, and the mixing and waiting times prior to application, in combination with implant surface
Previous retrieval studies demonstrate increased tibial baseplate
Purpose. Previous retrieval studies demonstrate increased tibial baseplate
The design of the femoral prosthesis in cementless total hip arthroplasty is known to affect the initial strains in the cortex during implantation and in the early postoperative time period. High strains have a direct influence on periprosthetic fracture. This study compares the existing ABGII stem, which is proximally coated with a grit blasted titanium surface with hydroxyapatite coating with a prototype that has a rougher titanium plasma spray proximal coating. The Australian National Joint registry results 2011 reported the ABG2 femoral component cumulative percent revision (CPR) of 6.5 (93.5% survival), which compares favourably with equivalent stems with 10 year CPR data such as the Taperloc 6.6 and Corail 7.3. Six pairs of fresh-frozen cadaveric femurs were mounted in blocks according to ISO guidelines in single leg stance setup. Five strain gauges were attached around the neck of the femur and then prepared according to routine operative techniques to accept the femoral prosthesis. Cortical strains were measured during insertion of the prosthesis with an instrumented mallet attached to an accelerometer. Subsequently, force-displacement readings were taken during cyclical loading on a servo-hydraulic machine and finally the stems were tested to failure. Our results showed significantly less strain during cyclical loading of the stem with increased surface
Aims. The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids. Methods. Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage. Results. At the completion of the wear test, the total thickness of the cartilage had significantly decreased in both the ceramic and metal groups, by 27% (p = 0.019) and 29% (p = 0.008), respectively. However, the differences between the two were not significant (p = 0.606) and the patterns of wear in the specimens were unpredictable. No significant correlation was found between cartilage wear and various factors, including age, sex, the size of the humeral head, joint mismatch, the thickness of the native cartilage, and the surface
Introduction. The release of metallic debris can promote many adverse tissue reactions, as metallosis, necrosis, pseudotumors and osteolysis . 1–3. This debris is mainly generated by the fretting-corrosion mechanism due to the geometric difference in the head-stem interface . 4. Retrieval and in silico analysis showed the
Aims. The aim of this study was to compare the design of the generic
OptiStem XTR femoral stem with the established Exeter femoral stem. Materials and Methods. We obtained five boxed, as manufactured, implants of both designs
at random (ten in total). Two examiners were blinded to the implant
design and independently measured the mass, volume, trunnion surface
topography, trunnion
Introduction. The accumulation of proteins and bacteria on implant surfaces is a critical concern in the biomedical field, especially with respect to the potential of biofilm formation on implant surfaces. Material surface wettability is often used as a predictor of potential colonization of specific bacterial strains. Surface