Advertisement for orthosearch.org.uk
Results 1 - 20 of 202
Results per page:
Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims. Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design. Methods. Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m. 2. (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds. Results. Mean acetabular subsidence from baseline to 24 months was 0.087 mm (SD 0.152), below the critical threshold of 0.2 mm (p = 0.005). Mean femoral subsidence from baseline to 24 months was -0.002 mm (SD 0.194), below the published reference of 0.5 mm (p < 0.001). There was significant improvement in patient-reported outcome measures at 24 months with good to excellent results. Conclusion. RSA analysis demonstrates excellent fixation with a predicted low risk of revision at ten years of this novel reverse total hip system. Clinical outcomes were consistent with safe and effective hip replacement prostheses. Cite this article: Bone Jt Open 2023;4(5):385–392


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 81 - 81
19 Aug 2024
Angelomenos V Shareghi B Itayem R Mohaddes M
Full Access

Early micromotion of hip implants measured with radiostereometric analysis (RSA) is a predictor for late aseptic loosening. Computed Tomography Radiostereometric Analysis (CT-RSA) can be used to determine implant micro-movements using low-dose CT scans. CT-RSA enables a non-invasive measurement of implants. We evaluated the precision of CT-RSA in measuring early stem migration. Standard marker-based RSA was used as reference. We hypothesised that CT-RSA can be used as an alternative to RSA in assessing implant micromotions. We included 31 patients undergoing Total Hip Arthroplasty (THA). Distal femoral stem migration at 1 year was measured with both RSA and CT-RSA. Comparison of the two methods was performed with paired-analysis and Bland-Altman plots. Furthermore, the inter- and intraobserver reliability of the CT-RSA method was evaluated. No statistical difference was found between RSA and CTMA measurements. The Bland-Altman plots showed good agreement between marker-based RSA and CT-RSA. The intra- and interobserver reliability of the CT-RSA method was found to be excellent (≥0.992). CT-RSA is comparable to marker-based RSA in measuring distal femoral stem migration. CTMA can be used as an alternative method to detect early implant migration


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims. The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods. A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. Results. The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee’s screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more anterior in the early flexion phase, while laterally the CP was more posterior during the entire movement cycle. The BCR-TKA group showed higher tibial migration. No differences were found for the clinical and functional outcomes. Conclusion. The BCR-TKA shows a different kinematic pattern in early flexion/late extension compared to the CR-TKA. The difference between both implants is mostly visible in the flexion phase in which the anterior cruciate ligament is effective; however, both designs fail to fully replicate the motion of a natural knee. The higher migration of the BCR-TKA was concerning and highlights the importance of longer follow-up. Cite this article: Bone Joint J 2023;105-B(1):35–46


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236


Bone & Joint Research
Vol. 6, Issue 6 | Pages 376 - 384
1 Jun 2017
Stentz-Olesen K Nielsen ET De Raedt S Jørgensen PB Sørensen OG Kaptein BL Andersen MS Stilling M

Objectives. Static radiostereometric analysis (RSA) using implanted markers is considered the most accurate system for the evaluation of prosthesis migration. By using CT bone models instead of markers, combined with a dynamic RSA system, a non-invasive measurement of joint movement is enabled. This method is more accurate than current 3D skin marker-based tracking systems. The purpose of this study was to evaluate the accuracy of the CT model method for measuring knee joint kinematics in static and dynamic RSA using the marker method as the benchmark. Methods. Bone models were created from CT scans, and tantalum beads were implanted into the tibia and femur of eight human cadaver knees. Each specimen was secured in a fixture, static and dynamic stereoradiographs were recorded, and the bone models and marker models were fitted to the stereoradiographs. Results. Results showed a mean difference between the two methods in all six degrees of freedom for static RSA to be within -0.10 mm/° and 0.08 mm/° with a 95% limit of agreement (LoA) ranging from ± 0.49 to 1.26. Dynamic RSA had a slightly larger range in mean difference of -0.23 mm/° to 0.16 mm/° with LoA ranging from ± 0.75 to 1.50. Conclusions. In a laboratory-controlled setting, the CT model method combined with dynamic RSA may be an alternative to previous marker-based methods for kinematic analyses. Cite this article: K. Stentz-Olesen, E. T. Nielsen, S. De Raedt, P. B. Jørgensen, O. G. Sørensen, B. L. Kaptein, M. S. Andersen, M. Stilling. Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data. Bone Joint Res 2017;6:376–384. DOI: 10.1302/2046-3758.66.BJR-2016-0113.R3


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 148 - 148
4 Apr 2023
Jørgensen P Kaptein B Søballe K Jakobsen S Stilling M
Full Access

Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry. 16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner- and neck movements were described as anteversion, inclination and rotation. Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute changes in the resulting liner/neck angle (small articulation) was 28° (12–46) and liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median (range) liner anteversion from 7° (-12–23) postoperatively to 10° (-3–16) at 1-year follow-up and inclination from 42 (35–66) postoperatively to 59 (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p=0.01). The polyethylene liner moves over time. One year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 11 - 11
1 May 2021
Skipsey DA Downing MR Ashcroft GP Cairns DA Kumar K
Full Access

Over the last decade stemless shoulder arthroplasty has become increasingly popular. However, stability of metaphyseal loading humeral components remains a concern. This study aimed to assess the stability of the Affinis stemless humeral component using Radiostereometric analysis (RSA). Patients underwent total shoulder arthroplasty via a standardised technique with a press-fit stemless humeral component and a cemented pegged glenoid. Tantalum beads were inserted into the humerus at the time of operation. RSA of the relaxed shoulder was completed at weeks 1, 6, 13, 26, 52 and 104 post-operatively. Stressed RSA with 12 newtons of abduction force was completed from week 13 onwards. ABRSA 5.0 software (Downing Imaging Limited, Aberdeen) was used to calculate humeral component migration and induced movement. 15 patients were recruited. Precision was: 0.041, 0.034, 0.086 and 0.101 mm for Superior, Medial, Posterior and Total Point Motion (TPM) respectively. The mean TPM over 2 years was 0.24 (0.30) mm, (Mean (Standard deviation)). The mean rate of migration per 3 month time period decreased from 0.45 (0.31) to 0.02 (0.01) mm over 2 years. Mean inducible movement TPM peaked at 26 weeks at 0.1 (0.08) mm, which reduced to 0.07 (0.06) mm by 104 weeks when only 3 patients had measurable inducible motion. There was no clear trend in direction of induced movement. There were no adverse events or revisions required. We conclude migration of the humeral component was low with little inducible movement in the majority of patients implying initial and 2 year stability of the stemless humeral component


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 3 - 3
1 Mar 2021
Chimutengwende-Gordon M Callary S Davidson J Costi K Pannach S Stamenkov R Howie DW Solomon LB
Full Access

Femoral impaction bone grafting (IBG) may be used to restore bone stock in revision total hip arthroplasty (THA) and allow use of a shorter, than otherwise, length prosthesis. This is most beneficial in young patients who are more likely to require further revision surgery. This study aimed to assess the results of femoral IBG for staged revision THA for infection. A prospective cohort of 29 patients who underwent staged revision THA for infection with femoral IBG and a cemented polished double-tapered (CPDT) stem at the final reconstruction was investigated. The minimum follow-up was two years (2 – 10 years, median 6 years). Stem subsidence was measured with radiostereometric analysis. Clinical outcomes were assessed with the Harris Hip, Harris Pain, and and Société Internationale de Chirurgie Orthopédique et de Traumatologie Activity (SICOT) Scores. The original infection was eradicated in 28 patients. One patient required a repeat staged revision due to re-infection with the same organism. At two-year follow-up, the median subsidence at the stem-bone interface was −1.70 mm (−0.31 to −4.98mm). The median Harris Hip Score improved from 51 pre-operatively to 80 at two years (p=0.000), the Harris Pain Score from 20 to 44 (p=0.000) and the SICOT Score from 2.5 to 3 (p=0.003). As successful eradication of infection was achieved in the majority of patients and the stem migration was similar to that of a primary CPDT stem, this study supports the use of femoral IBG during the final reconstruction of the femur after staged revision THA for infection


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 27 - 27
1 Jul 2020
Hurry J Spurway A Dunbar MJ El-Hawary R
Full Access

Radiostereometric analysis (RSA) allows for precise measurement of interbody distances on X-ray images, such as movement between a joint replacement implant and the bone. The low radiation biplanar EOS imager (EOS imaging, France) scans patients in a weight-bearing position, provides calibrated three-dimensional information on bony anatomy, and could limit the radiation during serial RSA studies. Following the ISO-16087 standard, 15 double exams were conducted to determine the RSA precision of total knee arthroplasty (TKA) patients in the EOS imager, compared to the standard instantaneous, cone-beam, uniplanar digital X-ray set-up. At a mean of 5 years post-surgery, 15 TKA participants (mean 67 years, 12 female, 3 male) were imaged twice in the biplanar imager. To reduce motion during the scan, a support for the foot was added and the scan speed was increased. The voltage was also increased compared to standard settings for better marker visibility over the implant. A small calibration object was included to remove any remaining sway in post-processing. The 95% confidence interval precision was 0.11, 0.04, and 0.15 mm in the x, y, and z planes, respectively and 0.15, 0.20, and 0.14° in Rx, Ry, and Rz. Two participants had motion artifacts successfully removed during post-processing using the small calibration object. With faster speeds and stabilization support, this study found an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20° for TKA exams, which is within published uniplanar values for arthroplasty RSA. The biplanar imager also adds the benefits of weight bearing imaging, 3D alignment measurements, a lower radiation dose, and does not require a reference object due to known system geometry and automatic image registration


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 37 - 37
1 May 2018
Ferguson R Broomfield J Malak T Palmer A Whitwell D Taylor A Glyn-Jones S
Full Access

Background. Short bone-conserving femoral stem implants were developed to achieve more physiological, proximal bone loading than conventional femoral stems. Concerns have arisen, however, that improved loading may be offset by lower primary stability because of the reduced potential area for bony contact. Aims. The aim of this study was to determine the primary stability of a novel short femoral stem compared with a conventional femoral stem following cementless total hip arthroplasty (THA), in a prospective, blinded, randomised, controlled trial using radiostereometric analysis. Methods. Fifty-three patients were randomised to receive cementless THA with either a short femoral stem or a conventional femoral stem. The CONSORT diagram is shown (Figure I). Surgery was performed at one institution by three surgeons. 26 patients received the short stem and 23 received the conventional stem. Complete follow-up was available on 40 patients (82%). All patients received the same cementless acetabular component. The primary outcomes were dynamically inducible micromotion and migration of the femoral stems at two years. Both were measured using radiostereometric analysis. Radiographs for radiostereometric analysis were taken post-operatively and at three, six, 12, 18 and 24 months. Validated geometric algorithms were used to determine the relative three-dimensional position of the prosthetic stem and host bone. Results. At two years, there was significantly less subsidence (inferior migration) of the short femoral stem (head: 0.28mm; 95% confidence interval [CI] +/−0.17; SD 0.38; tip: 0.10mm; 95% CI +/− 0.18; SD 0.41) compared with the conventional stem (head: 0.61mm, 95% CI +/−0.26, SD 0.55, P=0.03; tip: 0.44mm, 95% CI +/−0.21, SD 0.43, P=0.02) (Figure II). There was no significant difference in dynamically inducible micromotion. Conclusion. This study demonstrates that the short femoral stem has a stable and predictable migration. However, longer-term survival analysis remains important. For any figures and tables, please contact the authors directly


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1158 - 1166
14 Sep 2020
Kaptein BL den Hollander P Thomassen B Fiocco M Nelissen RGHH

Aims. The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs). Methods. A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively. Results. The overall migration (mean maximum total point motion (MPTM)) at two years was comparable: mean 1.13 mm (95% confidence interval (CI), 0.97 to 1.30) for the ATTUNE and 1.16 mm (95% CI, 0.99 to 1.35) for the PFC-sigma. At two years, the mean backward tilting was -0.43° (95% CI, -0.65 to -0.21) for the ATTUNE and 0.08° (95% CI -0.16 to 0.31), for the PFC-sigma. Overall migration between the first and second postoperative year was negligible for both components. The clinical outcomes and PROMs improved compared with preoperative scores and were not different between groups. Radiolucencies at the implant-cement interface were mainly seen below the medial baseplate: 17% in the ATTUNE and 3% in the PFC-sigma at two weeks, and at two years 42% and 9% respectively (p = 0.001). Conclusion. In the first two postoperative years the initial version of the ATTUNE tibial component was not inferior with respect to overall migration, although it showed relatively more backwards tilting and radiolucent lines at the implant-cement interface than the PFC-sigma. The version of the ATTUNE tibial component examined in this study has subsequently undergone modification by the manufacturer. Level of Evidence: 1 (randomized controlled clinical trial). Cite this article: Bone Joint J 2020;102-B(9):1158–1166


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 2 - 2
1 Feb 2020
Turgeon T Burnell C Hedden D Gascoyne T Bohm E
Full Access

Introduction. Total hip arthroplasty (THA) is a highly successful procedure achieving excellent clinical outcomes beyond 10 years post-surgery. With exception of periprosthetic infection, dislocation is the most common cause of failure in THA. A novel reverse total hip (RTH) replacement has been developed to address dislocation through reversal of the typical THA articulation in which a femoral cup and acetabular ball interlock at the extremes of motion to enhance mechanical stability in all planes. The purpose of this study was to assess the safety and efficacy of this novel RTH in a series of 22 patients and to monitor implant fixation using radiostereometric analysis (RSA). Methods. Twenty two patients with end-stage osteoarthritis of the hip were enrolled between 2017 and 2019 at a single center. All surgeries were performed by a group of four high-volume fellowship-trained arthroplasty surgeons. All patients received at least 1 acetabular cup screw and RSA markers inserted into the acetabulum and proximal femur. Follow-up time points were 6 weeks, 6, 12 and 24 months and included patient reported outcome measures (HOOS, Oxford-12, Harris Hip Score, SF-36 and Satisfaction) as well as RSA assessment. Results. The patient cohort consisted of 11 females and 11 males with mean age of 70.8 years and body mass index 31.3 kg/m. 2. At the time of writing, 21, 15 and 3 patients had completed their 6-month, 1- and 2-year clinical follow-ups, respectively. There was a significant improvement in function and pain with the RTH between pre-operative and six and twelve month follow up as collected by the HOOS, Oxfrod-12, HHS, WOMAC, EQ-5D and SF-36 PCS with p<0.001 for all. The sole exception was the SF-36 MCS which had a non-statistical improvement. Eighteen of 20 patients were satisfied or very satisfied with the outcome of surgery. Average vertical migration of the acetabular cup at 6 and 12 months was 0.082 mm and 0.110 mm, respectively. Average distal migration of the femoral stem at 6 and 12 months was 0.015 mm and 0.035 mm, respectively. Conclusions. Early results indicate acceptable safety and efficacy of this novel RTH for treating osteoarthritis of the hip. The femoral and acetabular components both appear well fixed at near-term follow-up, as assessed with RSA. Further follow-up will determine if these results are maintained at 24 months post-surgery. Additional patient enrollment will assess acetabular cup fixation without the use of screws. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 90 - 90
1 Feb 2020
Gascoyne T Parashin S Zarrabian M
Full Access

Introduction. This research determines the feasibility of radiostereometric analysis (RSA) as a diagnostic tool for assessing fusion following spinal arthrodesis. Further, to estimate clinical thresholds for precision and accuracy of the proposed method in the cervical and lumbar spine. Methods. Two-level lumbo-sacral and three-level cervical posterior arthrodesis procedures were performed on an artificial spine model and a cadaveric spine (Figure 1). Using a spring-loaded inserter, RSA marker beads were placed within each of the L4-S1 and C3-C6 vertebrae, then analyzed for optimal bead distribution and detection. RSA imaging consisted of 12 double exams (24 exams) of the cervical and lumbar regions for both the Sawbones and cadaveric spine to assess precision of measurement under zero-displacement conditions, defined as the 95% confidence interval of error. Accuracy assessment was performed on the Sawbones model in which the middle vertebrae (L5 and C4-C5) were moved relative to the superior (L4 and C3) and inferior (S1 and C6) vertebrae by known, incremental displacements (Figure 2). RSA images were obtained at each displacement (Figure 3). Accuracy was defined as the mean difference between known and measured displacements. Results. Median RSA bead detection was 100% in cervical vertebrae and >75% in lumbar vertebrae in the artificial and cadaveric models. Translational RSA precision for both spine models was better than 0.25mm and 0.82mm for the lumbar and cervical regions, respectively. Rotational precision was better than 0.4° and 1.9° for the lumbar and cervical regions, respectively. RSA accuracy for the artificial spine overall demonstrated less than 0.11 mm translational bias (margin < ±0.02 mm) and less than 0.22° rotational bias (margin < ±0.15°). Discussion and Conclusion. This study demonstrates that RSA achieves sufficient precision and accuracy to detect intervertebral micromotion for the purpose of assessing arthrodesis. Well dispersed bead placement is critical to achieving sufficient accuracy and avoiding occlusion by metal hardware. The results of this work will aid in the development of a clinical study to assess arthrodesis in patients. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 50 - 50
1 Jul 2020
Gascoyne T Parashin S Zarrabian M
Full Access

The purpose of this research was to determine the feasibility of radiostereometric analysis (RSA) as a diagnostic tool for assessing non-union following spinal arthrodesis procedures. Further, to estimate clinical thresholds for precision and accuracy of the proposed method in the cervical and lumbar spine. A three-level lumbo-sacral and a four-level cervical posterior arthrodesis procedures were performed on an artificial spine model (Sawbones, WA). Using a spring loaded inserter (RSA Biomedical, Sweden), eight to ten RSA markers were placed within each of the L4 and L5 segments in the spinous process (L4 only), lamina, transverse processes, posterior and anterior (down the pedicle) wall of the vertebral body. Eight to ten markers were placed within the proximal sacrum (S1) at the medial and lateral crests, tuberosity, and within the sacral canal wall. Four to eight RSA markers were placed into the C3-C6 lateral masses. Titanium screws and rods were applied to the spinal segments. Identical procedures were then performed on a cadaveric spine using similar bead placement and hardware. RSA imaging consisted of 12 double exams (24 exams) of the cervical and lumbar regions for both the Sawbones and cadaveric spine to assess precision of measurement under zero-displacement conditions. The most distal vertebrae were considered the datum against which the movement of all other vertebrae was compared. The artificial spine was then dismantled for accuracy assessment in which the middle vertebrae (L5 and C4-C5) were moved relative to the superior (L4 and C3) and inferior (S1 and C6) vertebrae by known, incremental displacements on an imaging phantom device. Displacements occurred along the superior-inferior, anterior-posterior, and flexion-extension (rotational) axes of motion. RSA images were obtained at each displacement. Image analysis was performed using model-based software (RSACore v3.41, Leiden, Netherlands) to visualize implanted RSA beads in 3-D space. Precision was defined as the 95% confidence interval of error in measuring zero-displacement. Accuracy was defined as the mean difference (with 95% confidence interval) between the known and measured displacement. The rate of RSA bead detection was high with 5–8 implanted beads being visible in both the lumbar and cervical regions of the artificial and cadaveric spines. Translational RSA precision for both spines was better than 0.25 mm and 0.82 mm for the lumbar and cervical regions, respectively. Rotational precision was better than 0.40° and 1.9° for the lumbar and cervical regions, respectively. RSA accuracy for the artificial spine overall demonstrated less than 0.11 mm translational bias (margin < ±0.02 mm) and less than 0.22° rotational bias (margin < ±0.15°). This study demonstrates that RSA achieves sufficient precision and accuracy to detect intervertebral micromotion for the purpose of assessing arthrodesis. Well dispersed RSA bead placement is critical to achieving sufficient accuracy as well as avoiding occlusion by metal hardware. Cervical bead implantation is particularly sensitive to bead clustering due to small vertebrae size and proximity to critical structures. The results of this work will aid in the development of a clinical study to assess arthrodesis in patients


Abstract. Introduction. Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA). Methodology. Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS). Results. Preliminary analysis of Maximum Total Point Motion (MTPM) indicated cementless tibial components undergo significantly more migration than cemented components during the first 6 months (1.6mm/year, SD=0.92 versus 1.3mm/year, SD=1.1, p<0.001). Cementless migration was predominantly subsidence inferiorly (Mean=0.51mm/year, SD=0.29, p<0.001) and posteriorly (0.13mm/year, SD=0.21, p=0.03). Contrastingly, from 6 months to 10 years cemented components migrated significantly (MTPM=0.039mm/year, SD=0.11, p=0.04) whereas cementless components did not (MTPM=0.002mm/year, SD=0.02, p=0.744). Radiolucent lines occurred more frequently below cemented (10/13) than cementless (4/16) tibial components, but radiolucencies did not correlate with differences in migration or OKS. There was no significant difference in OKS between cemented and cementless. Conclusion. These results suggest that cementless tibial components migrate more than cemented before achieving primary fixation. However, long-term fixation of cementless tibial components appears to be as good, if not better, than cemented with the benefit of fewer radiolucent lines


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 256 - 256
1 May 2009
Nuttall D Trail IA Stanley JK
Full Access

Purpose: To measure any observed migration and rotation of humeral and ulnar components using radiostereometric analysis. Methods: From 2002–2004 in a prospective study, twelve elbows in patients treated with either a linked(3) or unlinked(9) Acclaim total elbow prosthesis were included in a radiostereometry study. Six tantalum markers were introduced into the humerus another 3 markers were located on a humeral component. Four markers were placed in to ulna and three markers located on the ulnar component. RSA radiographs were taken postoperatively, six, twelve and twenty-four months. The radiographs were digitised and analysed using UmRSA software. The relative movement of the humeral and ulnar implants with respect to the bone was measured. Results: At twelve months, the largest rotation of the humeral component was anteversion/retroversion with a mean of 20, anterior tilt had a mean of 1.10 and varus/valgus tilt was minimal mean 0.60. Mean difference between twelve and 24 months segment rotation was no more than 0.50. Rotation in unlinked humeral implants reached a plateau at 12 months this did not occur in linked implants. Paired t-tests between twelve and 24 months segment translation data showed the mean differences to be no more than 0.04mm. In contrast, humeral tip motion produced a mean of 1.3mm at 12 months dominated by movement in the horizontal plane with a mean difference at 24 months of 0.2mm. Mean micro-motion of the ulna implant tip was 0.32mm at 12 months with a mean difference at 24 months of 0.1mm. Conclusions: Early micromotion of the Acclaim humeral implant occurs mostly by rotation about the vertical axis accompanied by anterior tilt. In unlinked implants this motion reaches a plateau at 12 months after operation but does occur in linked implants


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2019
Wilson C Critchely O Callary S Campbell D
Full Access

Introduction & aims. The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration. Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail hydroxyapatite-coated cementless stem at 10 years using RSA. Method. A prospective cohort of 30 patients undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration behaviour of a cementless stem. Tantalum markers were attached to the stem and placed in the bone intraoperatively, allowing for RSA measurements to be taken in vivo. Previous 5-year results have been presented. A total of 14 patients (total 15 hips, one bilateral) with mean age 82 years (range, 69–92 years) underwent repeat long-term RSA radiographs at minimum 10 years post op. The mean time to follow up was 13.9 years (range, 13.3–14.4 years). The RSA radiographs were analysed to assess for implant rotation and translation. Results. None of the 14 patients (15 hips) followed up have been revised. The migration (rotation and translation) at 6 months, 1 year, 2 years, and 6 years has been described previously. No stems had additional subsidence of more than 0.25 mm between 6 months and 6 years. The resultant mean subsidence between 2 years and 6 years was 0.03 mm, which is below the limit measurable by RSA. The long-term, 10-year results, on implant rotation and translation will be presented. Conclusions. The Corail stem exhibited variable subsidence within the first 6 months after which there is persistent stabilisation through to 6 years. 10-year results on long-term migration show no further migration. These results can be used as a gold standard for other uncemented stems


Bone & Joint Research
Vol. 4, Issue 5 | Pages 78 - 83
1 May 2015
Martinkevich P Rahbek O Møller-Madsen B Søballe K Stilling M

Objectives. Lengthening osteotomies of the calcaneus in children are in general grafted with bone from the iliac crest. Artificial bone grafts have been introduced, however, their structural and clinical durability has not been documented. Radiostereometric analysis (RSA) is a very accurate and precise method for measurements of rigid body movements including the evaluation of joint implant and fracture stability, however, RSA has not previously been used in clinical studies of calcaneal osteotomies. We assessed the precision of RSA as a measurement tool in a lateral calcaneal lengthening osteotomy (LCLO). Methods. LCLO was performed in six fixed adult cadaver feet. Tantalum markers were inserted on each side of the osteotomy and in the cuboideum. Lengthening was done with a plexiglas wedge. A total of 24 radiological double examinations were obtained. Two feet were excluded due to loose and poorly dispersed markers. Precision was assessed as systematic bias and 95% repeatability limits. Results. Systematic bias was generally below 0.10 mm for translations. Precision of migration measurements was below 0.2 mm for translations in the osteotomy. Conclusion. RSA is a precise tool for the evaluation of stability in LCLO. Cite this article: Bone Joint Res 2015;4:78–83


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 519 - 519
1 Oct 2010
Howie D Callary S Kane T McGee M Pannach S Russell N Solomon L Stamenkov R
Full Access

Introduction: In the past, surgeons have found impaction bone grafting technically difficult leading to its limited use. This paper reviews the long term results and developments in instrumentation and techniques aimed at simplifying femoral impaction grafting at revision hip replacement. The expanded indications for this procedure are reviewed and recent results of stem fixation using radiostereometric analysis (RSA) are reported. Methods: The impaction bone grafting procedure, using a cemented collarless polished double taper stem, has been used in 66 hips (median patient age 63yrs) since 1993. The technique has undergone numerous developments. Modular tamps have been used in the last 29 hips and in the last seven hips, a pneumatic mechanical vibration device has been used in place of manual impaction. Stem subsidence at both the prosthesis-cement and cement-graft/bone interfaces was measured, more recently using radiostereometric analysis. Results: There was a high early incidence of failure in the initial cases but there have been no further revisions for mechanical failure at up to 15 years. Technique developments have resulted in dramatic improvements in stem fixation achieved. In the modular tamp cases, the mean stem subsidence at the cement-bone interface at 12 months was 0.07mm (0 to 0.7mm) at 12 months. The stem subsidence in the hips where the mechanical vibration device was used was 0.05mm (0 to 0.06mm). Femoral impaction grafting offers special advantages in younger patients include standard femoral stem revision and at the second stage of two stage revision for infection. Discussion and Conclusion: A stable cement-bone interface is achieved using advanced techniques of femoral impaction grafting that includes the use of modular impaction instruments. Early results of mechanical vibration impaction are encouraging. Femoral impaction grafting restores bone and new techniques simplify the femoral revision procedure


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 57 - 57
1 Oct 2019
Broberg JS Teeter MG Lanting B Vasarhelyi EM Howard JL Yuan X Naudie DDR
Full Access

Introduction. Surgeons performing a total knee replacement (TKR) have two techniques to assist them achieve proper bone resections and ligament tension – gap balancing (GB) and measured resection (MR). GB relies on balancing ligaments prior to bony resections, whereas bony resections are made based on anatomical landmarks in MR. Many studies have been done to compare the implant migration and kinematics between the two techniques, but the results have been varied. However, these studies have not been done on modern anatomically designed prostheses using radiostereometric analysis (RSA). Anatomical designs attempt to mimic the normal knee joint structure to return more natural kinematics to the joint, with emphasis on eliminating both paradoxical anterior motion and reduced posterior femoral rollback. Given the major design differences between anatomical and non-anatomical prostheses, it is important to investigate whether one surgical technique may have advantages another. We hypothesize that there would be no difference between GB and MR techniques in implant migration, but that GB might provide better knee kinematics. Methods. Patients were recruited to receive an anatomically designed prosthesis and randomized to groups where the GB or MR technique is used. For all patients in the study, RSA images were acquired at a 2 week baseline, as well as at 6 weeks, 3 months, and 6 months post-operatively. These images were used to collect the maximum total point motion (MTPM) of the tibial and femoral implant components relative to the bone using a model-based RSA software. A series of RSA images were also acquired at 3-months post-operatively at different knee flexion angles, ranging in 20° increments from 0° to 100°. Model-based RSA software was used to obtain the 3D positions and orientations of the femoral and tibial components, which were used to obtain the anterior-posterior (AP) contact locations for each condyle. Results. Results from 47 patients (27 GB, 20 MR) were analyzed. No significant differences were present between the two surgical techniques for tibial component MTPM at 6 weeks (mean difference=0.02 mm, p=0.61), 3 months (mean difference=0.01 mm, p=0.92), and 6 months (mean difference=0.01 mm, p=0.93) post-operatively. No significant differences were present between the two surgical techniques for femoral component MTPM at 6 weeks (mean difference=0.12 mm, p=0.08), 3 months (mean difference=0.05 mm, p=0.54), and 6 months (mean difference=0.13 mm, p=0.05) post-operatively. On the medial condyle, no significant differences in AP contact location were found at all angles between 0° and 80° of flexion (p-values from 0.28 to 0.95). There was a significant difference medially between the AP contact location of the two surgical techniques at 100° of flexion (p=0.01), indicating more posterior rollback on the medial condyle in the GB technique. On the lateral condyle, no significant differences in AP contact location were found at all angles of flexion (p-values from 0.13 to 0.62). On the medial condyle of the GB group, the AP contact location moved posteriorly 5.83 mm from 0° to 20°, anteriorly 2.60 mm from 20° to 60°, and posteriorly 7.40 mm from 60° to 100°. On the medial condyle of the MR group, the AP contact location moved posteriorly 5.36 mm from 0° to 20°, anteriorly 2.87 mm from 20° to 60°, and posteriorly 3.65 mm from 60° to 100°. On the lateral condyle of the GB group, the AP contact location moved posteriorly 6.87 mm from 0° to 20°, 0.30 mm from 20° to 60°, and 3.61 mm from 60° to 100°. On the lateral condyle of the MR group, the AP contact location moved posteriorly 6.86 mm from 0° to 20°, anteriorly 0.02 mm from 20° to 60°, and posteriorly 3.56 mm from 60° to 100°. Conclusions. The GB and MR techniques are very similar in terms of implant migration and overall kinematics when an anatomical prosthesis design is used for TKR. This study suggests that surgeon preference should be used when deciding which technique to use for implanting this anatomically designed knee replacement. For figures, tables, or references, please contact authors directly