Advertisement for orthosearch.org.uk
Results 1 - 20 of 578
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 46 - 46
1 Dec 2022
de Vries G McDonald T Somayaji C
Full Access

Worldwide, most spine imaging is either “inappropriate” or “probably inappropriate”. The Choosing Wisely recommendation is “Do not perform imaging for lower back pain unless red flags are present.” There is currently no detailed breakdown of lower back pain diagnostic imaging performed in New Brunswick (NB) to inform future directions. A registry of spine imaging performed in NB from 2011-2019 inclusive (n=410,000) was transferred to the secure platform of the NB Institute for Data, Training and Research (NB-IRDT). The pseudonymized data included linkable institute identifiers derived from an obfuscated Medicare number, as well as information on type of imaging, location of imaging, and date of imaging. The transferred data did not include the radiology report or the test requisition. We included all lumbar, thoracic, and complete spine images. We excluded imaging related to the cervical spine, surgical or other procedures, out-of-province patients and imaging of patients under 19 years. We verified categories of X-ray, Computed Tomography (CT), and Magnetic Resonance Imaging (MRI). Red flags were identified by ICD-10 code-related criteria set out by the Canadian Institute for Health Information. We derived annual age- and sex-standardized rates of spine imaging per 100,000 population and examined regional variations in these rates in NB's two Regional Health Authorities (RHA-A and RHA-B). Age- and sex-standardized rates were derived for individuals with/without red flag conditions and by type of imaging. Healthcare utilization trends were reflected in hospital admissions and physician visits 2 years pre- and post-imaging. Rurality and socioeconomic status were derived using patients’ residences and income quintiles, respectively. Overall spine imaging rates in NB decreased between 2012 and 2019 by about 20% to 7,885 images per 100,000 people per year. This value may be higher than the Canadian average. Females had 23% higher average imaging rate than males. RHA-A had a 45% higher imaging rate than RHA-B. Imaging for red flag conditions accounted for about 20% of all imaging. X-rays imaging accounted for 67% and 75% of all imaging for RHA-A and RHA-B respectively. The proportions were 20% and 8% for CT and 13% and 17% for MRI. Two-year hospitalization rates and rates of physician visits were higher post-imaging. Females had higher age-standardized hospitalization and physician-visit rates, but the magnitude of increase was higher for males. Individuals with red flag conditions were associated with increased physician visits, regardless of the actual reason for the visit. Imaging rates were higher for rural than urban patients by about 26%. Individuals in the lowest income quintiles had higher imaging rates than those in the highest income quintiles. Physicians in RHA-A consistently ordered more images than their counterparts at RHA-B. We linked spine imaging data with population demographic data to look for variations in lumbar spine imaging patterns. In NB, as in other jurisdictions, imaging tests of the spine are occurring in large numbers. We determined that patterns of imaging far exceed the numbers expected for ‘red flag’ situations. Our findings will inform a focused approach in groups of interest. Implementing high value care recommendations pre-imaging ought to replace low-value routine imaging


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_9 | Pages 32 - 32
1 Sep 2019
Lemmers G van Lankveld W van der Wees P Westert G Staal J
Full Access

Background. Routine imaging (radiography, CT, MRI) provides no health benefits for low back pain (LBP) patients and is not recommended in clinical practice guidelines. Whether imaging leads to increased costs, healthcare utilization or absence from work is unclear. Purpose. To systematically review if imaging in patients with LBP increases costs, leads to higher health care utilization or increases absence from work. METHODS. Randomized controlled trials (RCTs) and observational studies (OSs), comparing imaging versus no imaging on targeted outcomes were extracted from medical databases until October 2017. Data extraction and risk of bias assessment was performed independently by two reviewers. The quality of the body of evidence was determined using GRADE methodology. Results. Moderate quality evidence (1 RCT; n=421) supports that direct costs increase for patients undergoing radiography. Low quality evidence (3 OSs; n=9535) supports that early MRI leads to a large increase in costs. Moderate quality evidence (2 RCTs, 6 OSs; n=19392) supports that performing MRI, radiography or CT is associated with increased healthcare utilization. Two RCTs (n=667) showed no significant differences between radiography or MRI groups compared with no imaging groups on absence from work. However, the results of two observational studies (n=7765) did show significantly greater absence from work in the imaging groups compared to the no imaging-groups. Conclusions. Imaging in LBP is associated with higher medical costs and increased healthcare utilisation. There are indications that it also leads to higher absence from work. No conflicts of interest. No funding obtained


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 67 - 67
7 Nov 2023
Mogale N van Schoor A Scott J Schantz D Ilyasov V Bush TR Slade JM
Full Access

Pressure ulcers are a common occurrence in individuals with spinal cord injuries, and are attributed to prolonged sitting and limited mobility. This therefore creates the need to better understand soft tissue composition, in the attempt to prevent and treat pressure ulcers. In this study, novel approaches to imaging the soft tissue of the buttocks were investigated in the loaded and unloaded position using ultrasound (US) and magnetic resonance imaging (MRI). Twenty-six able-bodied participants (n=26, 13 males and 13 females) were recruited for this study and 1 male with a spinal cord injury. Two visits using US were required, as well as one MRI visit to evaluate soft tissue thickness and composition. US Imaging for the loaded conditions was performed using an innovative chair which allowed image acquisition in the seated upright position and MRI was done in the lateral decubitus position and loading was applied to the buttocks using a newly developed MRI compatible loader. The unloaded condition was a lateral decubitus position. Soft tissue was measured between the peak of the ischial tuberosity (IT) and the proximal femur and skin. Tissue thickness reliability for US was excellent, ICC=0.934–0.981 with no significant differences between the scan days. US and MRI measures of tissue thickness were significantly correlated (r=0.68–0.91). US underestimated unloaded tissue thicknesses with a mean bias of 0.39 – 0.56 for total tissue and muscle + tendon thickness. When the buttocks were loaded, total tissue thickness was reduced by 64.2±9.1%. US assessment of soft tissue thicknesses was reliable in both positions. The unloaded measurements using US were validated with MRI with acceptable limits of agreement, albeit tended to underestimate tissue thickness. Tissue thickness, but not fatty infiltration of muscle played a role in how the soft tissue of the buttocks responded to loading


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 168 - 168
1 Feb 2004
Zibis A Dailiana Z Karantanas A Varitimidis S Malizos K
Full Access

Purpose: To review the MRI findings in transient osteoporosis of the hip (TOH) and to investigate the pattern of perfusion in dynamic studies. Material and Methods: Twenty-seven patients (29 hips), 23–66 years old, were referred for hip pain without history of trauma. In all patients the diagnosis of TOH based on x-rays (decrease bone density of the femoral head) and MRI (bone marrow edema-BME) was confirmed after complete resolution of symptoms and MRI findings after 6–18 months. MRI studies included T1-w SE, T2-w-SPIR-TSE and contrast enhanced T1-w TFE in dynamic mode and delayed SE. Imaging assessment included joint effusion, location and extent of BME (types A–D), sparing of the femoral head, subchondral linear lesions, and collapse. Results: Joint effusion was observed in 28 of 29 hips. The extent of BME in the femoral head was type A in 5/29 hips, B in 2/29, C in 16/29, D in 6/29. Associated BME of the acetabulum was depicted in 6/29 hips. In 12/29 hips the bone marrow edema was sparing the subchondral area. Subchondral line was only found in 2/29 hips. On dynamic T1–w images all hips presented with a delayed pattern of perfusion up to 40 sec. Conclusion: MRI findings are useful in diagnosing TOH and differentiating this entity from early AVN


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 118 - 118
10 Feb 2023
Sundaraj K Corbett J Yong Yau Tai J Salmon L Roe J
Full Access

The emergence of patient specific instrumentation has seen an expansion from simple radiographs to plan total knee arthroplasty (TKA) with modern systems using computed tomography (CT) or magnetic resonance imaging scans. Concerns have emerged regarding accuracy of these non-weight bearing modalities to assess true mechanical axis. The aim of our study was to compare coronal alignment on full length standing AP imaging generated by the EOS acquisition system with the CT coronal scout image. Eligible patients underwent unilateral or bilateral primary TKA for osteoarthritis under the care of investigating surgeon between 2017 and 2022, with both EOS X-Ray Imaging Acquisition System and CT scans performed preoperatively. Coronal mechanical alignment was measured on the supine coronal scout CT scan and the standing HKA EOS. Pre-operative lower limb coronal alignment was assessed on 96 knees prior to TKA on the supine coronal scout CT scan and the standing HKA EOS. There were 56 males (56%), and 44 right knees (44%). The mean age was 68 years (range 53-90). The mean coronal alignment was 4.7 degrees (SD 5.3) on CT scan and 4.6 degrees (SD 6.2) on EOS (p=0.70). There was a strong positive correlation of coronal alignment on CT scan and EOS (pearson. 0.927, p=0.001). The mean difference between EOS and CT scan was 0.9 degrees (SD 2.4). Less than 3 degrees variation between measures was observed in 87% of knees. On linear regression for every 1° varus increase in CT HKA alignment, the EOS HKA alignment increased by 0.93° in varus orientation. The model explained 86% of the variability. CT demonstrates excellent reliability for assessing coronal lower limb alignment compared to EOS in osteoarthritic knees. This supports the routine use of CT to plan TKA without further weight bearing imaging in routine cases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 30 - 30
17 Nov 2023
Swain L Holt C Williams D
Full Access

Abstract. Objectives. Investigate Magnetic Resonance Imaging (MRI) as an alternative to Computerised Tomography (CT) when calculating kinematics using Biplane Video X-ray (BVX) by quantifying the accuracy of a combined MRI-BVX methodology by comparing with results from a gold-standard bead-based method. Methods. Written informed consent was given by one participant who had four tantalum beads implanted into their distal femur and proximal tibia from a previous study. Three-dimensional (3D) models of the femur and tibia were segmented (Simpleware Scan IP, Synopsis) from an MRI scan (Magnetom 3T Prisma, Siemens). Anatomical Coordinate Systems (ACS) were applied to the bone models using automated algorithms. 1. The beads were segmented from a previous CT and co-registered with the MRI bone models to calculate their positions. BVX (60 FPS, 1.25 ms pulse width) was recorded whilst the participant performed a lunge. The beads were tracked, and the ACS position of the femur and tibia were calculated at each frame (DSX Suite, C-Motion Inc.). The beads were digitally removed from the X-rays (MATLAB, MathWorks) allowing for blinded image-registration of the MRI models to the radiographs. The mean difference and standard deviation (STD) between bead-generated and image-registered bone poses were calculated for all degrees of freedom (DOF) for both bones. Using the principles defined by Grood and Suntay. 2. , 6 DOF kinematics of the tibiofemoral joint were calculated (MATLAB, MathWorks). The mean difference and STD between these two sets of kinematics were calculated. Results. The absolute mean femur and tibia ACS position differences (Table 1) between the bead and image-registered poses were found to be within 0.75mm for XYZ, with all STD within ±0.5mm. Mean rotation differences for both bones were found to be within 0.2º for XYZ (Table 1). The absolute mean tibiofemoral joint translations (Table 1) were found to be within ±0.7mm for all DOF, with the smallest absolute mean in compression-distraction. The absolute mean tibiofemoral rotations were found to be within 0.25º for all DOF (Table 1), with the smallest mean was found in abduction-adduction. The largest mean and STD were found in internal-external rotation due to the angle of the X-rays relative to the joint movement, increasing the difficulty of manual image registration in that plane. Conclusion. The combined MRI-BVX method produced bone pose and tibiofemoral kinematics accuracy similar to previous CT results. 3. This allows for confidence in future results, especially in clinical applications where high accuracy is needed to understand the effects of disease and the efficacy of surgical interventions. Acknowledgements: This research was supported by the Engineering and Physical Sciences Research Council (EPSRC) doctoral training grant (EP/T517951/1). Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 23 - 23
24 Nov 2023
Xie C Ren Y Weeks J Lekkala S Rainbolt J Xue T Shu Y Lee K de Mesy Bentley KL Yeh S Schwarz E
Full Access

Title. Longitudinal Intravital Imaging to Quantify the “Race for the Surface” Between Host Immune Cell and Bacteria for Orthopaedic Implants with S. aureus Colonization in a Murine Model. Aim. To assess S. aureus vs. host cell colonization of contaminated implants vis intravital multiphoton laser scanning microscopy (IV-MLSM) in a murine model. Method. All animal experiments were approved by IACUC. A flat stainless steel or titanium L-shaped pin was contaminated with 10. 5. CFU of a red fluorescent protein (RFP) expressing strain of USA300LAC, and surgically implanted through the femur of global GFP-transgenic mice. IV-MLSM was performed at 2, 4, and 6 hours post-op. Parallel cross-sectional CFU studies were performed to quantify the bacteria load on the implant at 2,4,6,12,18 and 24 hours. Results. 1) We developed a high-fidelity reproducible IV-MLSM system to quantify S. aureus and host cell colonization of a bone implant in the mouse femur. Proper placement of all implants were confirmed with in vivo X-rays, and ex vivo photos. We empirically derive the ROI during each imaging session by aggregating the imaged volume which ranges from (636.4um × 636.4um × 151um) = 0.625 +/- 0.014 mm. 3. of bone marrow in a global GFP-transgenic mouse. 2) IV-MLSM imaging acquisition of the “race for the surface”.In vitro MPLSM images of implants partially coated with USA300LAC (RFP-MRSA) were verified by SEM image. Results from IV-MLSM of RFP-MRSA and GFP. +. host cell colonization of the contaminated implants illustrated the mutually exclusive surface coating at 3hrs, which to our knowledge is the first demonstration of “the race for the surface” between bacteria and host cells via intravital microscopy. 3) Quantifying the “race for the surface” with CFU verification of S. aureus on the implant. 3D volumetric rendering of the GFP. +. voxels and RFP+ voxels within the ROI were generated in Imaris. The voxel numbers suggeste that the fight for the surface concludes ∼3hrs post-infection, and then transitions to an aggressive MRSA proliferation phase. The results of WT control demonstrate a significant increase in CFU by 12hrs post-op for both stainless steel (P<0.01) and titanium (P<0.01). Conclusions. We developed IV-MLSM to quantify the “Race for the Surface” between host cells and contaminating S. aureus in a murine femur implant model. This race is remarkably fast, as the implant surface is completely covered with 3hrs, peak bacterial growth on the implant occurs between 2 and 12 hours and is complete by 12hrs


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 96 - 96
1 Oct 2012
Dubois-Ferriere V Hoffmeyer P Assal M
Full Access

In foot and ankle surgery incorrect placement of implants, or inaccuracy in fracture reduction may remain undiscovered with the use of conventional C-arm fluoroscopy. These imperfections are often only recognized on postoperative computer tomography scans. The apparition of three dimensional (3D) mobile Imaging system has allowed to provide an intraoperative control of fracture reduction and implant placement. Three dimensional computer assisted surgery (CAS) has proven to improve accuracy in spine and pelvic surgery. We hypothesized that 3D-based CAS could improve accuracy in foot and ankle surgery. The purpose of our study was to evaluate the feasibility and utility of a multi-dimensional surgical imaging platform with intra-operative three dimensional imaging and/or CAS in a broad array of foot and ankle traumatic and orthopaedic surgery. Cohort study of patients where the 3D mobile imaging system was used for intraoperative 3D imaging or 3D-based CAS in foot and ankle surgery. The imaging system used was the O-arm Surgical Imaging System and the navigation system was the Medtronic's StealthStation. Surgical procedures were performed according to standard protocols. In case of fractures, image acquisition was performed after reduction of the fracture. In cases of 3D-based CAS, image acquisition was performed at the surgical step before implants placement. At the end of the operations, an intraoperative 3D scan was made. We used the O-arm Surgical Imaging system in 11 patients: intraoperative 3D scans were performed in 3 cases of percutaneus fixation of distal tibio-fibular syndesmotic disruptions; in 2 of the cases, revision of reduction and/or implant placement were needed after the intraoperative 3D scan. Three dimensional CAS was used in 10 cases: 2 open reduction and internal fixation (ORIF) of the calcaneum, 1 subtalar fusion, 2 ankle arthrodesis, 1 retrograde drilling of an osteochondral lesion of the talus, 1 Charcot diabetic reconstruction foot and 1 intramedullary screw fixation of a fifth metatarsal fracture. The guidance was used essentially for screw placement, except in the retrograde drilling of an osteochondral lesion where the guidance was used to navigate the drill tool. Intraoperative 3D imaging showed a good accuracy in implant placement with no need to revision of implants. We report a preliminary case series with use of the O-arm Surgical Imaging System in the field of foot and ankle surgery. This system has been used either as intraoperative 3D imaging control or for 3D-based CAS. In our series, the 3D computer assisted navigation has been very useful in the placement of implants and has shown that guidance of implants is feasible in foot and ankle surgery. Intraoperative 3D imaging could confirm the accuracy of the system as no revisions were needed. Using the O-arm as intraoperative 3D imaging was also beneficial because it allowed todemonstrate intraoperative malreduction or malposition of implants (which were repositioned immediately). Intraoperative 3D imaging system showed very promising preliminary results in foot and ankle surgery. There is no doubt that intraoperative use of 3D imaging will become a standard of care. The exact indications need however to be defined with further studies


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 81 - 81
14 Nov 2024
Ahmed NA Narendran K Ahmed NA
Full Access

Introduction

Anterior shoulder instability results in labral and osseous glenoid injuries. With a large osseous defect, there is a risk of recurrent dislocation of the joint, and therefore the patient must undergo surgical correction. An MRI evaluation of the patient helps to assess the soft tissue injury. Currently, the volumetric three-dimensional (3D) reconstructed CT image is the standard for measuring glenoid bone loss and the glenoid index. However, it has the disadvantage of exposing the patient to radiation and additional expenses. This study aims to compare the values of the glenoid index using MRI and CT.

Method

The present study was a two-year cross-sectional study of patients with shoulder pain, trauma, and dislocation in a tertiary hospital in Karnataka. The sagittal proton density (PD) section of the glenoid and enface 3D reconstructed images of the scapula were used to calculate glenoid bone loss and the glenoid index. The baseline data were analyzed using descriptive statistics, and the Chi-square test was used to test the association of various complications with selected variables of interest.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 2 - 2
1 Apr 2019
Chappell K Van Der Straeten C McRobbie D Gedroyc W Brujic D Meeson R
Full Access

Introduction. Cruciate retaining knee replacements are only implanted into patients with “healthy” ligaments. However, partial anterior cruciate ligament (ACL) tears are difficult to diagnose with conventional MRI. Variations of signal intensity within the ligament are suggestive of injury but it is not possible to confirm damage or assess the collagen alignment within the ligaments. The potential use of Magic Angle Directional Imaging (MADI) as a collagen contrast mechanism is not new, but has remained a challenge. In theory, ligament tearing or joint degeneration would decrease tissue anisotropy and reduce the magic angle effect. Spontaneous cruciate ligament rupture is relatively common in dogs. This study presents results from ten canine knees. Methods. Ethical approval was obtained to collect knees from euthanized dogs requiring a postmortem (PM). A Siemens Verio 3T MRI scanner was used to scan a sphere containing the canine knees in 9 directions to the main magnetic field (B. 0. ) with an isotropic 3D-T1-FLASH sequence. After imaging, the knees were dissected and photographed. The images were registered and aligned to compare signal intensity variations. Segmentation using a thresholding technique identified voxels containing collagen. For each collagen-rich voxel the orientation vector was computed using Szeverenyi and Bydder's method. Each orientation vector reflects the net effect of all fibers comprised within a voxel. The assembly of all unit vectors represents the fiber orientation map and was visualised in ParaView using streamlines. The Alignment Index (AI) is defined as a ratio of the fraction of orientations within 20° (solid angle) centred in that direction to the same fraction in a random (flat) case. By computing AI for a regular gridded orientation space we can visualise differences in AI on a hemisphere. AI was normalised so that AI=0 indicates isotropic collagen alignment. Increasing AI values indicate increasingly aligned structures: AI=1 indicates that all collagen fibers are orientated within the cone of 20° centred at the selected direction. Results. Dogs cranial cruciate ligament (CCL) is similar to human ACL. It's composed of an anteromedial (AM) bundle and a posterolateral (PL) bundle. Two knees were damaged with partial CCL tears, the PL bundle was intact but the AM bundle was torn. Paraview streamlines of the CCL for healthy and damaged knees differ. The healthy knee has continuous fiber tracts with no ligament disruption. In the AM bundle fibers are discontinuous and the PL bundle fibers are continuous as expected in a partially torn CCL. The AI for healthy (mean AI=0.25) and damaged CCL (mean AI= 0.075) is significantly different (p<0.01). The damaged AM bundle has a more diffuse spread of less aligned fibers compared to the more concentrated and aligned PL fiber bundle. Conclusion. This study demonstrates the first visualisation of a CCL partial tear using MADI. Combined with AI, our scanning technique offers a tool to visualise and quantify changes in collagen fiber orientation. Thus, MRI can be used to improve the diagnosis and quantification of partial ligament tears in the knee


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 124 - 124
1 Jan 2016
Mclawhorn A Carroll K Esposito C Maratt J Mayman DJ
Full Access

Background. Digital templating is a critical part of preoperative planning for total hip arthroplasty (THA) that is increasingly used by orthopaedic surgeons as part of their preoperative planning process. Digital templating has been used as a method of reducing hospital costs by eliminating the need for acetate films and providing an accurate method of preoperative planning. Pre-operative templating can help anticipate and predict appropriate component sizes to help avoid postoperative leg length discrepancy, failure to restore offset, femoral fracture, and instability. A preoperative plan using digital radiographs for surgical templating for component size can improve intraoperative accuracy and precision. While templating on conventional and digital radiographs is reliable and accurate, the accuracy of templating on digital images acquired with a novel biplanar imaging system (EOS Imaging Inc, Cambridge, MA, USA) remains unknown. EOS imaging captures whole body images of a standing patient without stitching or vertical distortion, less magnification error and exposes patients to less radiation than a pelvis AP radiograph. Therefore, the purpose of this study was to compare EOS imaging and conventional anteroposterior (AP) xrays for preoperative digital templating for THA, and compare the results to the implant sizes used intraoperatively. Methods. Forty primary unilateral THA patients had preoperative supine AP xrays and standing EOS imaging. The mean age for patients was 61 ± 8 years, the mean body mass index 29 ± 6 kg/m. 2. and 21 patients were female. All patients underwent a THA with the same THA system (R3 Acetabular System and Synergy Cementless Stem, Smith & Nephew, TN, USA) by a single surgeon. Two blinded observers preoperatively templated using both AP xray and EOS imaging for each patient to predict acetabular size, femoral component size, and stem offset. All templating was performed by two observers with standard software (Ortho Toolbox, Sectra AB, Linköping, Sweden) [Figure 1] one week prior to surgery, and were compared using the Cronbach's alpha (∝) coefficient of reliability. The accuracy of templating was reported as the average percent agreement between the implanted size and the templated size for each component. Results. For templating acetabular component size, the exact size was predicted for 48% using AP xrays and 70% using EOS imaging, and within 1 size for 88% using xrays and 98% using EOS imaging. For templating femoral component size, the exact size was predicted exactly for 33% using AP xrays and 60% using EOS imaging, and within 1 size for 85% using xrays and 98% using EOS imaging (Figure 2). Interobserver agreement was excellent for acetabular components (Cronbach's α = 0.94) and femoral components (Cronbach's α = 0.96) using EOS imaging. Conclusions. This study demonstrates that preoperative digital templating for THA using EOS imaging is accurate, with excellent interobserver agreement. EOS imaging has less magnification error, which may partially explain the accuracy of our templating method


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 1 - 1
1 Nov 2022
Patel R
Full Access

Abstract

Aims

The aim of this study was to evaluate the indications for patients presenting with knee pain undergoing magnetic resonance imaging of the knee prior to referral to the orthopaedic department and to ascertain whether plain radiograph imagining would be more beneficial prior to an MRI scan.

Method

A retrospective review of all referrals received by the hospital over a 6-month period was performed. Patients with knee pain that underwent an MRI scan were classified into two age groups, under 50 years and over 50 years old. Patients having undergone Magnetic resonance imaging (MRI) prior to referral were identified, and findings of the scan were recorded. These patients were reviewed further to see if a plain radiograph had been completed prior to or after the MRI.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 26 - 26
1 Oct 2022
Bell J Owen D Meek K Terrill N Sanchez-Weatherby J Le Maitre C
Full Access

Background

An improved understanding of intervertebral disc (IVD) structure and function is required for treatment development. Loading induces micro-fractures at the interface between the nucleus pulposus (NP) and the annulus fibrosus (AF), which is hypothesized to induce a cascade of cellular changes leading to degeneration. However, there is limited understanding of the structural relationship between the NP and AF at this interface and particularly response to load. Here, X-ray scattering is utilised to provide hierarchical morphometric information of collagen structure across the IVD, especially the interface region under load.

Methodology

IVDs were imaged using the I22 SAXS/WAXS beamline at Diamond Light Source. Peaks associated with the D-banded structure of collagen fibrils were fitted to quantify their azimuthal distribution, as well the magnitude and direction of internal strains under static and applied strain (0–20%).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 7 - 7
1 Jun 2023
Harris PC Lacey S Steward A Sertori M Homan J
Full Access

Introduction

The various problems that are managed with circular external fixation (e.g. deformity, complex fractures) also typically require serial plain x-ray imaging.

One of the challenges here is that the relatively radio-opaque components of the circular external fixator (e.g. the rings) can obscure the view of the area of interest (e.g. osteotomy site, fracture site).

In this presentation we describe how the geometry of the x-ray beam affects the produced image and how we can use knowledge of this to our advantage.

Whilst this can be applied to any long bone, we have focused on the tibia, given that it's the most common long bone that is treated by circular external fixation.

Materials & Methods

In the first part of the presentation we describe the known attributes (geometry) of the x-ray beam and postulate what effect it would have when we x-ray a long bone that is surrounded by a circular external fixator.

In the second part we demonstrate this in practice using a tibia and a 3 ring circular external fixator. Differing x-ray beam orientations are used to demonstrate both how the geometry of the beam affects the produced image and how we can use this to our advantage to better visualise part of the bone.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 126 - 126
14 Nov 2024
Lu C Lian W Wu R Lin Y Su C Chen C Tai M Chen Y Wang S Wang F
Full Access

Introduction

Cartilage damage is a critical aspect of osteoarthritis progression, but effective imaging strategies remain limited. Consequently, multimodal imaging approaches are receiving increased attention. Gold nanomaterials, renowned for their therapeutic and imaging capabilities, hold promise in drug development. However, their potential for cartilage imaging is rarely discussed. Here, we developed a versatile nanomaterial, AuNC@BSA-Gd-I, for cartilage detection. By leveraging electrostatic interactions with sulfated glycosaminoglycans (sGAG), the AuNC@BSA-Gd-I can effectively penetrate damaged cartilage while accumulating minimally in healthy cartilage. This probe can be visualized or detected using CT, MRI, IVIS, and a gamma counter, providing a comprehensive approach to cartilage imaging. Additionally, we compared the imaging abilities, cartilage visualization capacities, and versatility of currently disclosed multimodal gold nanomaterials with those of AuNC@BSA-Gd-I.

Method

The physicochemical properties of nanomaterials were measured. The potential for cartilage visualization of these nanomaterials was assessed using an in vitro porcine model. The sGAG content in cartilage was determined using the dimethylmethylene blue (DMMB) assay to establish the correlation between sGAG concentration and imaging intensity acquired at each modality.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 129 - 129
1 May 2016
Carroll K Esposito C Miller T Lipman J Padgett D Jerabek S Mayman D
Full Access

Introduction. Implant position plays a major role in the mechanical stability of a total hip replacement. The standard modality for assessing hip component position postoperatively is a 2D anteroposterior radiograph, due to low radiation dose and low cost. Recently, the EOS® X-Ray Imaging Acquisition System has been developed as a new low-dose radiation system for measuring hip component position. EOS imaging can calculate 3D patient information from simultaneous frontal and lateral 2D radiographs of a standing patient without stitching or vertical distortion, and has been shown to be more reliable than conventional radiographs for measuring hip angles[1]. The purpose of this prospective study was to compare EOS imaging to computer tomography (CT) scans, which are the gold standard, to assess the reproducibility of hip angles. Materials and Methods. Twenty patients undergoing unilateral THA consented to this IRB-approved analysis of post-operative THA cup alignment. Standing EOS imaging and supine CT scans were taken of the same patients 6 weeks post-operatively. Postoperative cup alignment and femoral anteversion were measured from EOS radiographs using sterEOS® software. CT images of the pelvis and femur were segmented using MIMICS software (Materialise, Leuven, Belgium), and component position was measured using Geomagic Studio (Morrisville, NC, USA) and PTC Creo Parametric (Needham, MA). The Anterior Pelvic Plane (APP), which is defined by the two anterior superior iliac spines and the pubic symphysis, was used as an anatomic reference for acetabular inclination and anteversion. The most posterior part of the femoral condyles was used as an anatomic reference for femoral anteversion. Two blinded observers measured hip angles using sterEOS® software. Reproducibility was analysed by the Bland-Altman method, and interobserver reliability was calculated using the Cronbach's alpha (∝) coefficient of reliability. Results. The Bland-Altman analysis of test-retest reliability indicated that the 95% limits of agreement between the EOS and CT measurements ranged from −3° to 4° for acetabular inclination, from −5° to 5° for acetabular anteversion, and from −7° to 2° for femoral anteversion. The average difference between EOS measurements and CT measurements was 2° ± 2° for acetabular inclination, 3°± 2° degrees for acetabular anteversion and 4° ± 4° femoral anteversion. Interobserver agreement was good for acetabular inclination (Cronbach's α = 0.55), acetabular anteversion (Cronbach's α = 0.76) and femoral components (Cronbach's α = 0.98) using EOS imaging. Conclusions. EOS imaging can accurately and reliably measure hip component position, while exposing patients to a much lower dose of radiation than a CT scan


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 54 - 54
1 Jan 2003
Donell ST
Full Access

Imaging techniques including MR scanning and ultrasound were discussed. However it was noted that for standard orthopaedic practice in the UK plain films were the initial imaging available. The importance of taking a skyline view was stressed. The Dejour protocol was then outlined where the lateral Xray of the knee assesses the patellar height, the presence of dysplasia of the trochlear groove, and, if present, its boss height. A CT scan defines the patellar tilt angle, and with cuts through the tibial tubercle, the offset of the tibial tubercle from the trochlear groove (TTTG). The four abnormalities that can be defined are then corrected at operation. All patients undergo a lateral release. If the patellar tilt angle is greater than 20° then a medial reefing is performed. If the patellar height is greater than 1.2, a distalisation of the tibial tubercle to correct this to 1.0 is done. A MG of greater than 2Omm leads to a correction by an Elmsie medial tubercle transfer. A boss height of greater than 6mm suggests a trochleoplasty should be performed. However the Dejour protocol is yet to be validated. It was concluded that imaging is essential for analysing patellofemoral instability. Plain films alone do not give enough information. Patterns of patellofemoral instability as assessed by CT scan (and MRI scan) are yet to be established. Postoperative imaging to confirm correction of abnormalities should be done. The measurements are worthwhile but their validation is awaited


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 36 - 36
1 May 2016
Benard M Heesterbeek P Wymenga A
Full Access

Background. Total knee arthroplasty (TKA) is a cost-effective surgical procedure for degenerative knee disease and has good long-term results. However, these results are not always related to patient satisfaction and functional outcome. With an increasing demand of surgeons and patients on functioning of total knee implants, the need for adequate objective outcome measures is high. Imaging of the knee is commonly used in clinical practice and research to objectively measure many different outcome parameters concerning the implant, such as alignment and complications.1 However, techniques on comparison of the sagittal contour of the knee before and after implant placement are scarce. Goal. To develop and describe a standardized method for measuring the sagittal contour of the implant in a 3D model of the knee before and after implant placement. Methods. Images of the static knee of a subject are obtained in-vivo using fluoroscopy over a 180° sweep at 15 frames per second (MultiDiagnost Eleva, Philips, The Netherlands). A 3D model of the knee is constructed in accompanying software (3D-RX, Philips, The Netherlands) and is subsequently imported in OsiriX imaging software (Pixmeo, Switzerland). In Osirix, a reproducible coordinate system is obtained using the bone stub axis and the anatomical epicondylar axis as references [Fig. 1]. We quantified the sagittal contour of the distal femur in two parameters: the flexion angle of femoral component and the sagittal profile of the implant. To measure the flexion angle, the image is located in the midtrochlear plane. The angle is measured between the bone stub axis and the neutral line of the femoral component [Fig. 2]. To measure the sagittal profile of the distal femur, the lengths of three lines connecting the anatomical epicondylar axis of the distal femur and the outer border of the femur/prosthesis are summed. This is done both anterior and posterior [Fig. 3]. These profiles are measured in planes of the lateral and medial condyle and of the midtrochlear plane. Due to the reproducible coordinate system, the profiles can be compared for the knee before and after implant placement. Conclusion. Using fluoroscopy and readily available 3D imaging software we have developed a technique for measuring valuable parameters concerning implant placement in TKA. This technique can be used for scientific purposes concerning comparison of the knee before and after implant placement and to study its effect on functional and biomechanical outcome after TKA


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 36 - 36
1 Jan 2011
Eardley W Stewart M
Full Access

Shoulder Instability impacts on the ability of military personnel to fulfil their operational role and maintain sporting competence. Magnetic Resonance Imaging (MRI) and Arthrogram (MRA) are increasingly available as diagnostic adjuncts. We analysed MR reports from personnel undergoing stabilisation, correlating clinical diagnosis with operative findings and reviewed the literature in order to recommend improvements. We report a retrospective, consecutive case note analysis of 106 personnel undergoing open anterior capsulolabral reconstruction (ACLR) by a single surgeon. Seventy patients had MR (48 MRA, 22 MRI). Commonly reported pathology included Hill Sachs Lesions (41%), Soft tissue (59%) and bony Bankart lesions (16%), capsular laxity (20 %), supraspinatus lesion (20%), ACJ disease (13%) and SLAP tear (12%). The sensitivity of MR for identification of labral lesions was 82% with a specificity of 86%. For bony glenoid lesions, sensitivity was 63% and specificity 94%. Disparity between report and operative findings occurred mainly in standard MRI. Patients with lesions unrelated to instability achieved a pain free functioning shoulder following stabilisation. 100% of patients referred for ACLR with clinical evidence of instability without MR had positive pre-operative and operative correlation with instability. In 5 cases, the original equivocal MRI was repeated by MRA due to clinical suspicion of instability. In all cases the repeat MRA correlated with pre-operative and operative findings of instability. In 5 cases with equivocal clinical findings, MRA provided confirmation of instability. Delay in referral due to scanning and follow up ranged from 0 – 15 weeks. The diagnosis of those instigating referral is accurate. Reporting of MR is open to variation and has cost implications. MRA performed by a radiologist with a musculoskeletal specialist interest is recommended on an individual basis only and routine use of non-arthrographic studies should be discontinued. This will improve the efficiency of the fast track pathway


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 21 - 21
1 Dec 2022
Kim D Dermott J Lebel D Howard AW
Full Access

Primary care physicians rely on radiology reports to confirm a scoliosis diagnosis and inform the need for spine specialist referral. In turn, spine specialists use these reports for triage decisions and planning of care. To be a valid predictor of disease and management, radiographic evaluation should include frontal and lateral views of the spine and a complete view of the pelvis, leading to accurate Cobb angle measurements and Risser staging. The study objectives were to determine 1) the adequacy of index images to inform treatment decisions at initial consultation by generating a score and 2) the utility of index radiology reports for appropriate triage decisions, by comparing reports to corresponding images.

We conducted a retrospective chart and radiographic review including all idiopathic scoliosis patients seen for initial consultation, aged three to 18 years, between January 1-April 30, 2021. A score was generated based on the adequacy of index images to provide accurate Cobb angle measurements and determine skeletal maturity (view of full spine, coronal=two, lateral=one, pelvis=one, ribcage=one). Index images were considered inadequate if repeat imaging was necessary. Comparisons were made between index radiology report, associated imaging, and new imaging if obtained at initial consultation. Major discrepancies were defined by inter-reader difference >15°, discordant Risser staging, or inaccuracies that led to inappropriate triage decisions. Location of index imaging, hospital versus community-based private clinic, was evaluated as a risk factor for inadequate or discrepant imaging.

There were 94 patients reviewed with 79% (n=74) requiring repeat imaging at initial consultation, of which 74% (n=55) were due to insufficient quality and/or visualization of the sagittal profile, pelvis or ribcage. Of index images available for review at initial consult (n=80), 41.2% scored five out of five and 32.5% scored two or below. New imaging showed that 50.0% of those patients had not been triaged appropriately, compared to 18.2% of patients with a full score. Comparing index radiology reports to initial visit evaluation with <60 days between imaging (n=49), discrepancies in Cobb angle were found in 24.5% (95% CI 14.6, 38.1) of patients, with 18.4% (95% CI 10.0, 31.4) categorized as major discrepancies. Risser stage was reported in only 14% of index radiology reports. In 13.8% (n=13) of the total cohort, surgical or brace treatment was recommended when not predicted based on index radiology report. Repeat radiograph (p=0.001, OR=8.38) and discrepancies (p=0.02, OR=7.96) were increased when index imaging was obtained at community-based private clinic compared to at a hospital. Re-evaluation of available index imaging demonstrated that 24.6% (95% CI 15.2, 37.1) of Cobb angles were mis-reported by six to 21 degrees.

Most pre-referral paediatric spine radiographs are inadequate for idiopathic scoliosis evaluation. Standardization of spine imaging and reporting should improve measurement accuracy, facilitate triage and decrease unnecessary radiation exposure.