Advertisement for orthosearch.org.uk
Results 401 - 450 of 1226
Results per page:

The aim of this study is the comparative assessment of long term clinical (subjective and objective), functional and quality of life outcome data between primary and revision THA.

122 patients (130 hips) who underwent cementless revision THA of both components (TMT cup, Wagner SL stem, Zimmer Biomet) for aseptic loosening only (Group A) were compared to a matched group of 100 patients (100 hips) who underwent cementless primary THA for osteoarthritis (Synergy stem, R3 cup, Smith & Nephew) (Group B). Outcomes were evaluated with survival analysis curves, Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford hip score (OHS), Short form-12 health survey (SF-12) and EQ-5D-5L scales. Mobility was assessed with walking speed, timed up and go test (TUG), Parker mobility, Lower extremity function score (LEFS) and UCLA scores.

At a mean follow up of 14.4 years (10 to 20) a cumulative success rate of 96% (95% CI 96 to 99%) in Group A and 98% (95% CI 97 to 99%) in Group B with operation for any reason as an end point was recorded. Statistically significant differences between groups were developed for WOMAC (Mann-Whitney U test, p= 0.014), OHS (Mann-Whitney U test, p= 0.020) and physical component of SF-12 scores (Mann-Whitney U test, p= 0.029) only. In Group A, in multiple regression analysis, patients’ cognition (p=0.001), BMI (p=0.007) and pain (p=0.022) were found to be independent factors influencing functional recovery (WOMAC). Similarly, pain (p=0.03) was found to influence quality of life (EQ-5D-5).

In the long term, revision THA shows satisfactory but inferior clinical, functional, and quality of life outcomes when compared to primary THA. Residual pain, BMI and cognitive impairment independently affect functional outcomes.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 37 - 37
1 Nov 2021
Girard J
Full Access

The management of prosthetic joint infection (PJI) has been widely performed for total hip arthroplasties (THA), but none has compared it with hip resurfacing arthroplasty (RSA). We also carried out a retrospective case-control study comparing the surgical treatment of PJI by surgical debridement and implant retention between RSA and THA in order to clarify whether there was a difference in terms of (1) successful healing of PJI (2) functional scores after recovery (3) risk factors for recurrence of PJI. Our hypothesis was that simple debridement with prosthesis retention regardless of the timeframe allowed to obtain a higher success rate for RSA compared to THA.

From 2010 to 2018, a single-center case-control study based on 3056 RSA found 13 PJI were age-matched (based on the 139 THA PJI treated) with 15 THA PJI (mean age of 53 years old (47–58) for THA and 59 (45–66) for RSA (p=0.34)). We compared their survival (absence of infectious recurrence) and the means differences between the 2 groups (demographical, clinical and biological data).

There was no difference between the 2 groups concerning: age (p=0.3), BMI (p=0.4), initial diagnosis (p=0.4), operating time for primary surgery (p=0.3), the presence of a postoperative hematoma (p=0.4), the type of bacteria (p=0.5), the total duration of antibiotic therapy (p=0.9) and the type of antibiotic therapy (p=0.6). Early postoperative infections (less than 6 weeks) occurred in 7/13 RSA cases (54%) compared to 11/15 THA cases (73%). At the mean follow-up of 5 years (2–7), the success rate without recurrence was significantly higher in the RSA group 100% versus 66.7% (10/15) for the THA group (p=0.044). At the last follow-up, the Oxford Hip Score was higher in the RSA versus THA group's (14 versus 22 p=0.004).

Simple surgical debridement an RSA without changing implants after PJI can be done regardless of the time to onset of infection. This is secondary to the absence of metaphyseal bone invasion and the low content of joint fluid.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 52 - 52
1 Nov 2021
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M Yamaguchi R
Full Access

Although periacetabular osteotomies are widely used for the treatment of symptomatic acetabular dysplasia, the surgical outcomes after long term follow-up are still limited. Thus, we assessed hip survival and patient-reported outcomes (PROMs) at 20 years after the transposition osteotomy of acetabulum (TOA).

Among 260 hips in 238 patients treated with TOA, 172 hips in 160 patients were evaluated at average 20.8 years, excluding patients who died or lost to follow-up. Kaplan-Meier analysis was used to assess survivorship with an end-point of THA. PROMs were evaluated using the VAS satisfaction, VAS pain, Oxford hip score (OHS), and Forgotten joint score (FJS). The thresholds of favorable outcomes of FJS and OHS were obtained using the receiver-operating characteristic curve with VAS satisfaction ≥ 50 and VAS pain < 20 as anchors.

Thirty-three hips (19.2%) underwent THA at average 13.3 years after TOA. Kaplan-Meier analysis revealed hip survival rate at 20 years was 79.7%. Multivariate analysis showed the preoperative Tönnis grade significantly influenced hip survival. Survival rates with Tönnis grade 0, grade 1, and grade 2 were 93.3%, 86.7%, and 54.8% at 20 years, respectively. More than 60% of the patients showed favorable PROMs (VAS satisfaction ≥ 50, VAS pain < 20, OHS ≥ 42, FJS ≥ 51). Advanced Tönnis grade at the latest follow-up and higher BMI were significantly associated with unfavorable OHS, but not with other PROMs.

This study demonstrated the durability of TOA for hips with Tönnis grade 0–1 and favorable satisfaction in majority of the patients at 20 years after surgery. Current presence of advanced osteoarthritis is associated with the lower hip function (OHS), but not necessarily associated with subjective pain and satisfaction. Higher BMI also showed a negative impact on postoperative function.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 7 - 7
1 Nov 2021
Morlock M Bätz J Beverland D Board T Lampe F Konow T
Full Access

The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) have rarely been studied due to the difficult quantification. Meanwhile registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant-size, -position, press-fit, contact area, primary stability and the effect of using a powered impaction tool.

Primary hip stems were implanted in 16 cadaveric femur pairs by three experienced surgeons using manual and powered impaction. Quantitative CTs were taken before and after each process step and stem tilt, canal-fill-ratio, pressfit and contact area between bone and implant determined. 11 femur pairs were additionally tested for primary stability under cyclic loading conditions.

Higher variations in press-fit and contact area between the surgeons for manual impactions compared to powered were observed. Stem tilt and implant sizing varied between surgeons but not between impaction methods. Larger stems exhibited less micromotion compared to smaller stems.

Larger implants may increase PPF risk, while smaller implants reduce primary stability. The reduced variation for powered impactions indicates that appropriate measures may promote a more standardized process. The observed variations between the experienced surgeons may represent the acceptable range for this specific stem design. Variability in the implantation process warrants further investigations since certain deviations e.g. a stem tilt towards varus, might increase bone stresses and PPF risk.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 2 - 2
1 Nov 2021
Delaunay C
Full Access

Aim of this work is to critically analyze the current mandatory trend to adapt femoral cementless implant shape as to allow their use through mini-invasive anterior hip approach (MIS-AA).

During decades, designers of cementless stems tried to adapt implant shapes to patient anatomy, that led to various classification systems (straight, curved, anatomic, etc …). Another way to classify cementless stems is according to their longevity, outcome quality and long-term results. This is the goal of the Orthopaedic Data Evaluation Panel (ODEP) that provided in 2017 an approved list of prostheses that meet at least the NICE 10y revision rate standard.

In the last available ODEP 2020 issue, the best rating (13y experience “13”, with strong evidence “A” and < 6.5% rev rate “∗”) was achieved by only 10 cementless implant: Mallory-Head®, Taperloc®, Bimetric®, Accolade®, SL-Alloclassic®, Corail®, CLS Spotorno®, Furlong®, Synergy® & Versys Fibermetal®. All 10 are Ti straight tapers with large metaphyseal morphology in particular in Gruen Zone I. All these 10 ODEP 13A∗ cementless stems can universally be implanted through postero-lateral (PL), MIS-PL, lateral & conventional anterior approaches, but not safely through MIS-AA. Conversely, only new short and curved stems can be inserted safely through MIS-AA. Indeed, surgeons who promote MIS-AA cannot routinely use those successful femoral implants classified ODEP 13A∗.

Obviously, surgical approach determines the choice of femoral component. Surgeons who promote MIAA can only bet/hope that these new short curved implants with currently very few clinical evidence will reach the same success and longevity that ODEP 13A∗ conventional straight tapers. Only future long-term studies will address that concern.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 23 - 23
1 Nov 2021
Hernigou P
Full Access

Symptomatic and non-symptomatic hip osteonecrosis related to sickle cell disease (SCD) has a high risk of progression to collapse and total hip arthroplasty (THA) in this disease has a high rate of complications. We asked question about the benefit of performing an IRM to detect and treat with cell therapy an early (stage I or II) contralateral osteonecrosis.

430 consecutive SCD adult (32 years, 18 to 51) patients (225 males) with bilateral osteonecrosis (diagnosed with MRI) were included in this study from 1990 to 2010. One side with collapse was treated with THA and the contralateral without collapse (stage I or II) treated with cell therapy. The volume of osteonecrosis was measured with MRI. For cell therapy, the average total number of mesenchymal stem cells (MSCs) counted as number of colony forming units-fibroblast injected in each hip was 160,000 ± 45,000 cells (range 75,000 to 210,000 cells).

At the most recent FU (20 years, range 10 to 30), among the 430 hips treated with cell therapy, 45 hips (10.5%) had collapsed and had required THA at 10 years (range 5 to 14 years) and 380 hips (88%) were without collapse and asymptomatic (or with few symptoms) with a decrease percentage of necrosis on MRI from 45% to 11%. Among the 430 contralateral THA, 96 (22.3%) had required one revision, 28 had a re-revision, and 12 a third re-revision with aseptic loosening (85% of revisions) and/or infection (6% of revisions). Hips undergoing cell therapy were approximately three times less likely to undergo revision or re-revision surgery (p < 0.01) as compared with hips undergoing a primary THA.

THA is the usual treatment of collapsed ON in patients with SCD. In this population, it is worth looking with MRI for an early stage on the contralateral hip and performing (when necessary) bone marrow cell implantation during the same anesthesia as for arthroplasty.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 45 - 45
1 Nov 2021
Sugano N Hamada H Takao M Ando W Uemura K Nakamura N
Full Access

The purposes of this study were to evaluate the accuracy and feasibility of a robotic preparation for acetabular metal augments in patients with developmental dysplasia of the hip (DDH). Mako robotic arm reaming was used in 7 DDH to prepare the bony cavities for both Trident PSL cups and Tritanium acetabular wedge augments in six hips with Crowe 2 or 3 DDH. In CT-based planning, a properly sized cup was placed in the original acetabulum, and the same sized cup was also placed to fit the superolateral acetabular defect. The coordinates of the planned positions of cup and augment were recorded to manage the robotic arm reaming. After registration of the patient's pelvis, robotic reaming was performed first for the augment, then, for the cup by changing the target position of reaming as planned. The accuracy of the cup and augment placement was assessed on postoperative CT. To evaluate the feasibility of the robotic procedure, the OR time and blood loss were compared with those of 13 patients who received the same cup and augment systems with a conventional technique. All procedures were done without fracture or fixation failure. There were no differences in OR time or blood loss between the two procedures. Postoperative CT measurements of the distance between the cup center and the augment sphere center showed less than 2mm difference from the Mako preoperative planning.

Although a longer time of follow up evaluation is mandatory, our robotic acetabular augment preparation technique is accurate and feasible.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 27 - 27
1 Nov 2021
Gehrke T Althaus L Linke P Salber J Krenn V Citak M
Full Access

Arthrofibrosis is a relatively frequent complication after total knee arthroplasty. Although stiffness after total hip arthroplasty (THA), because of formation of heterotopic ossification or other causes, is not uncommon, to the authors’ best knowledge, arthrofibrosis after THA has not been described. The aim of this study is to describe the arthrofibrosis of the hip after primary total hip arthroplasty using an established clinical and histological classification of arthrofibrosis.

We retrospectively examined all patients who were histologically confirmed to have arthrofibrosis after primary THA during revision surgery by examination of tissue samples in our clinic. Arthrofibrosis was diagnosed according to the histopathological SLIM-consensus classification, which defines seven different SLIM types of the periimplant synovial membrane. The SLIM type V determines the diagnosis of endoprosthesis-associated arthrofibrosis.

The study population consists of 66 patients who were revised due to arthrofibrosis after primary THA. All patients had a limitation in range of motion prior to revision with a mean flexion of 90° (range from 40 to 125), mean internal rotation of 10° (range from 0 to 40) and mean external rotation of 20° (range from 0 to 50). All patients had histological SLIM type V arthrofibrosis, corresponding to endoprosthesis-associated arthrofibrosis. Histological examination revealed that seven patients (10.6%) had particle-induced and 59 patients (89.4%) had non-particle-induced arthrofibrosis.

This is the first decription of endoprosthetic-associated arthrofibrosis after primary THA on the basis of a well-established histological classification. Our study results could enable new therapeutic and diagnostic opportunities in patients with such an arthrofibrosis. Surgeons should keep arthrofibrosis as a possible cause for stiffness and pain after primary total hip arthroplasty in mind. Level of evidence Diagnostic study, Level of Evidence IV

Thorsten Gehrke and Lara Althaus contributed equally to the writing of this manuscript.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 41 - 41
1 Nov 2021
Rudelli S Rudelli M Giglio P Rudelli B
Full Access

Hip instability is one of the most common complications after total hip arthroplasty (THA). Among the possible techniques to treat and prevent hip dislocation, the use of constrained liners is a well-established option. However, there is concern regarding the longevity of these devices due to higher mechanical stress caused by limited hip motion. The primary aim of this paper is to analyze the failure rate of a specific constrained liner in a series of consecutive cases.

This study is a retrospective consecutive case series of THA and revision hip arthroplasty (RHA), in which a constrained polyethylene insert was used to treat or prevent hip instability. Patients were divided in 3 different groups (THA for hip fracture, THA for osteoarthrosis, and RHA). Survival analysis was performed for failure, defined as at least one episode of hip dislocation or radiographical signs of acetabular loosening. Logistical regression was used to investigate risk factors for failure.

A total of 103 patients were included in the study. Fourteen patients (13,6%) were THA for osteoarthrosis, 60 (58,3%) were THA for hip fracture, and 29(28,2%) were RHA. The median follow-up was 28 months (ranging 12 − 173 months). Failure occurred in 4 cases (3,9%) comprehending 2 dislocations (1,9%) and 2 early acetabular loosening (1,9%). Amongst the groups, there were no cases of failures in the THA due to osteoarthrosis, in the THA for hip fracture there were 3 cases (5%) and in the RHA one case (3,4%). Failure-free survival was not statistically different between groups. There were no risk factors statistically related to failure.

The use of constrained acetabular insert to prevent or treat instability achieved an adequate survival time with a low rate of complications. Further studies are necessary to corroborate our findings.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 48 - 48
1 Nov 2021
Santore R
Full Access

To quantify the prevalence of Generalized Joint Hypermobility (GJH), aka Hypermobility Spectrum Disorder, in adult patients presenting with hip pain to a sub-specialty hip practice, this 4-year, prospective, observational study evaluated correlations with clinical, demographic, and baseline outcomes.

1,004 consecutive new hip patients (390 males, 614 females) were evaluated for GJH using the Beighton 9-point physical exam criteria and the Hakim-Grahame 5-item history questionnaire. Diagnosis, age, sex and race were tested as predictors of GJH. Patient reported outcomes from iHOT-12 and a modified Harris Hip Score (mHHS) were also assessed.

There were 333 patients presenting with hip dysplasia over this period. Hip dysplasia (DDH) patients without osteoarthritis (OA) had a significantly elevated prevalence of GJH (77.9%) compared to non-dysplastic hip patients (32.8%, p<0.0001) or to patients with DDH+OA (35.7%, p<0.0001). The prevalence of GJH was significantly higher in females (OR=4.2, 95% CI: 3.2 to 5.5, p<0.0001) and inversely proportional to age. Hispanic patients presented with significantly lower prevalence of GJH compared with other races (p<0.05). GJH was not a predictor of patient-reported outcomes scores (p=0.51 for iHOT-12 and p=0.44 for mHHS). During the course of this study, we successfully performed our first PAO procedure on an outpatient basis (February 2019). That is currently our standard practice.

With a strong correlation observed between hypermobility and developmental dysplasia of the hip (DDH), further research is warranted to explore the genetic basis and significance of this association.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 629 - 638
20 Oct 2021
Hayashi S Hashimoto S Kuroda Y Nakano N Matsumoto T Ishida K Shibanuma N Kuroda R

Aims

This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH).

Methods

The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 639 - 649
19 Oct 2021
Bergiers S Hothi H Henckel J Di Laura A Belzunce M Skinner J Hart A

Aims

Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning.

Methods

3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham hip replacements (BHRs) allowed the co-registration of their acetabular wear maps and their computational models, segmented from CT scans. The in vivo location of edge-wear was measured within a standardized coordinate system, defined using the anterior pelvic plane.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 858 - 864
18 Oct 2021
Guntin J Plummer D Della Valle C DeBenedetti A Nam D

Aims

Prior studies have identified that malseating of a modular dual mobility liner can occur, with previous reported incidences between 5.8% and 16.4%. The aim of this study was to determine the incidence of malseating in dual mobility implants at our institution, assess for risk factors for liner malseating, and investigate whether liner malseating has any impact on clinical outcomes after surgery.

Methods

We retrospectively reviewed the radiographs of 239 primary and revision total hip arthroplasties with a modular dual mobility liner. Two independent reviewers assessed radiographs for each patient twice for evidence of malseating, with a third observer acting as a tiebreaker. Univariate analysis was conducted to determine risk factors for malseating with Youden’s index used to identify cut-off points. Cohen’s kappa test was used to measure interobserver and intraobserver reliability.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 834 - 841
11 Oct 2021
O'Connor PB Thompson MT Esposito CI Poli N McGree J Donnelly T Donnelly W

Aims

Pelvic tilt (PT) can significantly change the functional orientation of the acetabular component and may differ markedly between patients undergoing total hip arthroplasty (THA). Patients with stiff spines who have little change in PT are considered at high risk for instability following THA. Femoral component position also contributes to the limits of impingement-free range of motion (ROM), but has been less studied. Little is known about the impact of combined anteversion on risk of impingement with changing pelvic position.

Methods

We used a virtual hip ROM (vROM) tool to investigate whether there is an ideal functional combined anteversion for reduced risk of hip impingement. We collected PT information from functional lateral radiographs (standing and sitting) and a supine CT scan, which was then input into the vROM tool. We developed a novel vROM scoring system, considering both seated flexion and standing extension manoeuvres, to quantify whether hips had limited ROM and then correlated the vROM score to component position.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 813 - 824
7 Oct 2021
Lerch TD Boschung A Schmaranzer F Todorski IAS Vanlommel J Siebenrock KA Steppacher SD Tannast M

Aims

The effect of pelvic tilt (PT) and sagittal balance in hips with pincer-type femoroacetabular impingement (FAI) with acetabular retroversion (AR) is controversial. It is unclear if patients with AR have a rotational abnormality of the iliac wing. Therefore, we asked: are parameters for sagittal balance, and is rotation of the iliac wing, different in patients with AR compared to a control group?; and is there a correlation between iliac rotation and acetabular version?

Methods

A retrospective, review board-approved, controlled study was performed including 120 hips in 86 consecutive patients with symptomatic FAI or hip dysplasia. Pelvic CT scans were reviewed to calculate parameters for sagittal balance (pelvic incidence (PI), PT, and sacral slope), anterior pelvic plane angle, pelvic inclination, and external rotation of the iliac wing and were compared to a control group (48 hips). The 120 hips were allocated to the following groups: AR (41 hips), hip dysplasia (47 hips) and cam FAI with normal acetabular morphology (32 hips). Subgroups of total AR (15 hips) and high acetabular anteversion (20 hips) were analyzed. Statistical analysis was performed using analysis of variance with Bonferroni correction.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 693 - 703
1 Oct 2021
Wang X Wang D Xia P Cheng K Wang Q Wang X Lin Q Song J Chen A Li X

Aims

To evaluate the effect of ultrasound-targeted simvastatin-loaded microbubble destruction (UTMDSV) for alleviation of the progression of osteoarthritis (OA) in rabbits through modulation of the peroxisome proliferator-activated receptor (PPARγ).

Methods

In vitro, OA chondrocytes were treated with ultrasound (US), US-targeted microbubble destruction (UTMD), simvastatin (SV), and UTMDSV on alternate days for four weeks. Chondrocytes were also treated with PPARγ inhibitor, PPARγ inhibitor+ UTMDSV, and UTMDSV. The cholesterol efflux rate and triglyceride levels were measured using an assay kit and oil red O staining, respectively. In vivo, the OA rabbits were treated with a single intra-articular injection of UTMD, SV, and UTMDSV every seven days for four weeks. Cartilage histopathology was assessed by safranin-O staining and the Mankin score. Total cholesterol (TC) and high-density lipoprotein-cholesterol (HDL-C) in rabbit knee synovial fluid were detected by enzyme-marker assay. Aggrecan, collagen II, and PPARγ expression levels were analyzed by Western blotting (WB).


Bone & Joint Research
Vol. 10, Issue 9 | Pages 594 - 601
24 Sep 2021
Karunaseelan KJ Dandridge O Muirhead-Allwood SK van Arkel RJ Jeffers JRT

Aims

In the native hip, the hip capsular ligaments tighten at the limits of range of hip motion and may provide a passive stabilizing force to protect the hip against edge loading. In this study we quantified the stabilizing force vectors generated by capsular ligaments at extreme range of motion (ROM), and examined their ability to prevent edge loading.

Methods

Torque-rotation curves were obtained from nine cadaveric hips to define the rotational restraint contributions of the capsular ligaments in 36 positions. A ligament model was developed to determine the line-of-action and effective moment arms of the medial/lateral iliofemoral, ischiofemoral, and pubofemoral ligaments in all positions. The functioning ligament forces and stiffness were determined at 5 Nm rotational restraint. In each position, the contribution of engaged capsular ligaments to the joint reaction force was used to evaluate the net force vector generated by the capsule.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 765 - 772
14 Sep 2021
Silitonga J Djaja YP Dilogo IH Pontoh LAP

Aims

The aim of this study was to perform a cross-cultural adaptation of Oxford Hip Score (OHS) to Indonesian, and to evaluate its psychometric properties.

Methods

We performed a cross-cultural adaptation of Oxford Hip Score into Indonesian language (OHS-ID) and determined its internal consistency, test-retest reliability, measurement error, floor-ceiling effect, responsiveness, and construct validity by hypotheses testing of its correlation with Harris Hip Score (HHS), vsual analogue scale (VAS), and Short Form-36 (SF-36). Adults (> 17 years old) with chronic hip pain (osteoarthritis or osteonecrosis) were included.


Bone & Joint Research
Vol. 10, Issue 9 | Pages 574 - 590
7 Sep 2021
Addai D Zarkos J Pettit M Sunil Kumar KH Khanduja V

Outcomes following different types of surgical intervention for femoroacetabular impingement (FAI) are well reported individually but comparative data are deficient. The purpose of this study was to conduct a systematic review (SR) and meta-analysis to analyze the outcomes following surgical management of FAI by hip arthroscopy (HA), anterior mini open approach (AMO), and surgical hip dislocation (SHD). This SR was registered with PROSPERO. An electronic database search of PubMed, Medline, and EMBASE for English and German language articles over the last 20 years was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We specifically analyzed and compared changes in patient-reported outcome measures (PROMs), α-angle, rate of complications, rate of revision, and conversion to total hip arthroplasty (THA). A total of 48 articles were included for final analysis with a total of 4,384 hips in 4,094 patients. All subgroups showed a significant correction in mean α angle postoperatively with a mean change of 28.8° (95% confidence interval (CI) 21 to 36.5; p < 0.01) after AMO, 21.1° (95% CI 15.1 to 27; p < 0.01) after SHD, and 20.5° (95% CI 16.1 to 24.8; p < 0.01) after HA. The AMO group showed a significantly higher increase in PROMs (3.7; 95% CI 3.2 to 4.2; p < 0.01) versus arthroscopy (2.5; 95% CI 2.3 to 2.8; p < 0.01) and SHD (2.4; 95% CI 1.5 to 3.3; p < 0.01). However, the rate of complications following AMO was significantly higher than HA and SHD. All three surgical approaches offered significant improvements in PROMs and radiological correction of cam deformities. All three groups showed similar rates of revision procedures but SHD had the highest rate of conversion to a THA. Revision rates were similar for all three revision procedures.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 757 - 764
1 Sep 2021
Verhaegen J Salih S Thiagarajah S Grammatopoulos G Witt JD

Aims

Periacetabular osteotomy (PAO) is an established treatment for acetabular dysplasia. It has also been proposed as a treatment for patients with acetabular retroversion. By reviewing a large cohort, we aimed to test whether outcome is equivalent for both types of morphology and identify factors that influenced outcome.

Methods

A single-centre, retrospective cohort study was performed on patients with acetabular retroversion treated with PAO (n = 62 hips). Acetabular retroversion was diagnosed clinically and radiologically (presence of a crossover sign, posterior wall sign, lateral centre-edge angle (LCEA) between 20° and 35°). Outcomes were compared with a control group of patients undergoing PAO for dysplasia (LCEA < 20°; n = 86 hips). Femoral version was recorded. Patient-reported outcome measures (PROMs), complications, and reoperation rates were measured.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims

The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs).

Methods

We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 696 - 704
1 Sep 2021
Malhotra R Gautam D Gupta S Eachempati KK

Aims

Total hip arthroplasty (THA) in patients with post-polio residual paralysis (PPRP) is challenging. Despite relief in pain after THA, pre-existing muscle imbalance and altered gait may cause persistence of difficulty in walking. The associated soft tissue contractures not only imbalances the pelvis, but also poses the risk of dislocation, accelerated polyethylene liner wear, and early loosening.

Methods

In all, ten hips in ten patients with PPRP with fixed pelvic obliquity who underwent THA as per an algorithmic approach in two centres from January 2014 to March 2018 were followed-up for a minimum of two years (2 to 6). All patients required one or more additional soft tissue procedures in a pre-determined sequence to correct the pelvic obliquity. All were invited for the latest clinical and radiological assessment.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 710 - 720
1 Sep 2021
Kjaervik C Gjertsen J Engeseter LB Stensland E Dybvik E Soereide O

Aims

This study aimed to describe preoperative waiting times for surgery in hip fracture patients in Norway, and analyze factors affecting waiting time and potential negative consequences of prolonged waiting time.

Methods

Overall, 37,708 hip fractures in the Norwegian Hip Fracture Register from January 2014 to December 2018 were linked with data in the Norwegian Patient Registry. Hospitals treating hip fractures were characterized according to their hip fracture care. Waiting time (hours from admission to start of surgery), surgery within regular working hours, and surgery on the day of or on the day after admission, i.e. ‘expedited surgery’ were estimated.


Bone & Joint Research
Vol. 10, Issue 9 | Pages 558 - 570
1 Sep 2021
Li C Peng Z Zhou Y Su Y Bu P Meng X Li B Xu Y

Aims

Developmental dysplasia of the hip (DDH) is a complex musculoskeletal disease that occurs mostly in children. This study aimed to investigate the molecular changes in the hip joint capsule of patients with DDH.

Methods

High-throughput sequencing was used to identify genes that were differentially expressed in hip joint capsules between healthy controls and DDH patients. Biological assays including cell cycle, viability, apoptosis, immunofluorescence, reverse transcription polymerase chain reaction (RT-PCR), and western blotting were performed to determine the roles of the differentially expressed genes in DDH pathology.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 611 - 617
10 Aug 2021
Kubik JF Bornes TD Klinger CE Dyke JP Helfet DL

Aims

Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck.

Methods

A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed.


Bone & Joint Research
Vol. 10, Issue 8 | Pages 498 - 513
3 Aug 2021
Liu Z Lu C Shen P Chou S Shih C Chen J Tien YC

Aims

Interleukin (IL)-1β is one of the major pathogenic regulators during the pathological development of intervertebral disc degeneration (IDD). However, effective treatment options for IDD are limited. Suramin is used to treat African sleeping sickness. This study aimed to investigate the pharmacological effects of suramin on mitigating IDD and to characterize the underlying mechanism.

Methods

Porcine nucleus pulposus (NP) cells were treated with vehicle, 10 ng/ml IL-1β, 10 μM suramin, or 10 μM suramin plus IL-1β. The expression levels of catabolic and anabolic proteins, proinflammatory cytokines, mitogen-activated protein kinase (MAPK), and nuclear factor (NF)-κB-related signalling molecules were assessed by Western blotting, quantitative real-time polymerase chain reaction (qRT-PCR), and immunofluorescence analysis. Flow cytometry was applied to detect apoptotic cells. The ex vivo effects of suramin were examined using IDD organ culture and differentiation was analyzed by Safranin O-Fast green and Alcian blue staining.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 2 - 2
1 Aug 2021
Seewoonarain S Stavri R Behforootan S Abel R
Full Access

Hip fractures are associated with poor outcomes and high mortality rates of 30%. The current gold standard to measure bone fragility is a Dual-Energy X-ray Absorptiometry (DEXA) scan measuring bone mineral density. Yet DEXA under-diagnoses bone fragility by 50% (1). To combat the burden of bone fragility, this experimental study combined ultrasound (US) with a sophisticated computational algorithm, namely full wave inversion (FWI), to evaluate femoral bone structure.

The aims were to assess the association of bone structure between the proximal femoral diaphysis and femoral neck; secondly to evaluate whether transverse ultrasound could assess bone structure of the proximal femoral diaphysis.

Bone structure of 19 ex vivo human femora was assessed by micro-CT analysis (mean age 88.11 years, male:female 13:6)(Nikon HMXST 225). Using ImageJ/BoneJ, three 10.2mm subsections of proximal diaphysis and femoral neck underwent analysis: the total bone volume fraction, cortical parameters (bone volume fraction, porosity, thickness) and trabecular parameters (porosity, thickness, spacing and connectivity).

A unique US prototype was developed to analyse fifteen femoral diaphyseal subsections using two P4-1 transducers with a novel tomography sequence (Verasonics, Matlab ver R2019a, FWI TRUST protocol). Comparative quantitative analysis of US and Micro-CT measurements was assessed (Graphpad Prism 8.3.1).

Micro-CT analysis of the proximal femoral diaphysis demonstrated low correlation to the femoral neck (Pearson r −0.54 to 0.55). US was able to capture cortical structure, though a wide limit of agreement seen when compared to micro-CT analysis (Bland-Altman range 36–59% difference).

This novel US technique was able to capture cortical bone structure. Improvements in methodology and technology are required to improve the analysis of trabecular bone and overall accuracy. Further evaluation of US and FWI is required to develop the technique and determine its role in clinical practice.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 7 - 7
1 Aug 2021
Kennedy I Ng N Young D Kane N Marsh A Meek D
Full Access

Cement-in-cement revision of the femoral component represents a widely practiced technique for a variety of indications. In this study we compare the clinical and radiological outcomes of two polished tapered stems.

From our prospectively collated database we identified all patients undergoing cement-in-cement revision from January 2005 – 2013 who had a minimum of two years follow-up. All cases were performed by the senior author using either an Exeter short revision stem or the C-stem AMT high offset No 1. Patients were followed-up annually with clinical and radiological assessment.

Ninety-seven patients matched the inclusion criteria. There were 50 Exeter and 47 C-stem AMT components. There were no significant differences between the patient demographics in either group. Mean follow-up was 9.7 years. A significant improvement in OHS, WOMAC and SF-12 scores was observed in both cohorts. Leg lengths were significantly shorter in the Exeter group, with a mean of -4mm in this cohort compared to 0mm in the C-stem AMT group. One patient in the Exeter group had early evidence of radiological loosening. In total, 16 patients (15%) underwent further revision of the femoral component (seven in the C-stem AMT group and nine in the Exeter group). No femoral components were revised for aseptic loosening. There were two cases of femoral component fracture in the Exeter group.

Our series shows promising long-term outcomes for the cement-in-cement revision technique using either the Exeter or C-stem AMT components. These results demonstrate that cement-in-cement revision using a double or triple taper-slip design is a safe and reliable technique when used for the correct indications.


The protective effect of lipped polyethylene uncemented acetabular liners against revision THA for instability has been reported. However, the effect of lip size has not been explored, nor has the effect on revision THA for loosening. We aimed to determine if uncemented acetabular liner geometry, and lip size, influences the risk of revision THA for instability or loosening.

202511 primary THAs with uncemented polyethylene acetabular components were identified from the NJR dataset (2003 – 2017). The effect of acetabular liner geometry and lip size on the risk of revision THA for instability or loosening was investigated using binomial regression and competing risks survival analyses (competing risks were revision for other causes or death) adjusting for age, gender, ASA grade, diagnosis, side, institution type, surgeon grade, surgical approach, head size and polyethylene crosslinking.

The distribution of acetabular liners was: neutral – 39.4%, offset neutral – 0.9%, 10-degree – 34.5%, 15-degree – 21.6%, 20-degree – 0.8%, offset reorientating – 2.82%. There were 690 (0.34%) revision THAs for instability and 604 (0.3%) for loosening. Significant subhazard risk ratios were found in revision THA for instability with 10-degree (0.63), 15-degree (0.48) and offset reorientating (1.6) liners, compared to neutral liners. There was no association found between liner geometry and risk of revision THA for loosening.

This Registry based study confirms a significantly lower risk of revision THA for instability when a lipped liner is used, compared to neutral liners, and a higher risk with the use of offset reorientating liners. Furthermore, 15degree liners seem to have a lower risk than 10degree liners. We did not find an association between acetabular liner geometry and revision THA for loosening.

10- and 15-degree lipped polyethylene liners seem to offer a lower revision risk over neutral liners, at least at medium term followup. Further studies are required to confirm if this benefit continues into the long-term.


Our previous work presented at BHS revealed a reduced risk of revision for all reasons in THAs using lipped (asymmetric) liners. Some audience members felt that this finding may be due to unaccounted confounders and the hip surgery community remains sceptical.

A fully adjusted Cox model was built after exploratory Kaplan-Meier analyses. The following surgical approaches were included in the analysis: Posterior, Hardinge/anterolateral, Other. The variables included in the final Cox model included: Gender, liner asymmetry, age, head composition, stem fixation method, head diameter, indication for implantation and surgical approach. An additional analysis of the 3 most commonly used polyethylene liners with both a flat and asymmetric version was performed.

In the fully adjusted Cox model, the use of a flat liner was associated with increased risk of revision for instability (HR: 1.79, 95%CI: 1.52–2.10) and increased risk of revision for all reasons (HR 1.195, 95%CI: 1.104 – 1.293) when compared to THAs utilising flat liners. This finding was upheld in the product specific analysis.

When utilising flat liners, the Hardinge/anterolateral approach was associated with a reduced risk of revision for instability compared to the posterior approach (HR 0.56, 95%CI: 0.446 to 0.706). When an asymmetric liner was used, there was no significant difference in the risk of revision for instability between the Hardinge/anterolateral approach and the posterior approach (HR 0.838, 95%CI: 0.633 – 1.110).

The use of polyethylene-based bearings gives the surgeon the option to use asymmetric liners. The reduced risk of revision in THAs with asymmetric liners was seen in the analysis of the complete dataset and in the product specific analysis. Our results demonstrate that the posterior approach, when used with asymmetric XLPE liners, is not associated with a higher risk of revision for instability as historical data suggested.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 12 - 12
1 Aug 2021
Deere K Matharu G Ben-Shlomo Y Wilkinson J Blom A Sayers A Whitehouse M
Full Access

A recent French report suggested that cobalt metal ions released from total hip replacements (THRs) were associated with an increased risk of dilated cardiomyopathy and heart failure. If the association is causal the consequences would be significant given the millions of Orthopaedic procedures in which cobalt-chrome is used annually. We examined whether cobalt-chrome containing THRs were associated with an increased risk of all-cause mortality, heart failure, cancer, and neurodegenerative disorders.

Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 375,067 primary THRs with up to 14·5 years follow-up. Implants were grouped as either containing cobalt-chrome or not containing cobalt-chrome. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined.

There were 132,119 individuals (35·2%) with an implant containing cobalt-chrome. There were 48,106 deaths, 27,406 heart outcomes, 35,823 cancers, and 22,097 neurodegenerative disorders. There was no evidence of an association that patients with cobalt-chrome implants had higher rates of any of the outcomes. For all-cause mortality there was a very small survival advantage for patients having a cobalt-chrome implant (restricted mean survival time 13·8=days, 95% CI=6·8-20·9).

Cobalt-chrome containing THRs did not have an increased risk of all-cause mortality, heart failure, cancer, and neurodegenerative disorders into the second decade post-implantation. Our findings will reassure clinicians and patients that primary THR is not associated with systemic implant effects.


Total hip replacement (THR) for end-stage osteoarthritis is a commonly performed cost-effective procedure, which provides patients with significant clinical improvement. Estimating the future demand for joint replacement is important to identify the healthcare resources needed. We estimated the number of primary THRs that will need to be performed up to the year 2060.

We used data from The National Joint Registry for England, Wales, Northern Ireland and the Isle of Man on the current volume of primary THR (n=94,936) performed in 2018. We projected future numbers of THR using a static estimated rate from 2018 applied to population growth forecast data from the UK Office for National Statistics up to 2060.

By 2060, primary THR volume would increase from 2018 levels by an estimated 37.7% (n=130,766). For both males and females demand for surgery was also higher for patients aged 70 and over, with older patients having the biggest relative increase in volume over time: 70–79 years (144.6% males, 141.2% females); 80–89 years (212.4% males, 185.6% females); 90 years and older (448.0% males, 298.2% females).

By 2060 demand for THR is estimated to increase by almost 40%. Demand will be greatest in older patients (70 years+), which will have significant implications for the health service that requires forward planning given morbidity and resource use is higher in this population. There is a backlog of current demand with cancellation of elective surgery due to seasonal flu pressures in 2017 and now Covid-19 in 2020. Orthopaedics already has the largest waiting list of any speciality. These issues will negatively impact the health services ability to deliver timely joint replacement to many patients for a number of years and require urgent planning.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 15 - 15
1 Aug 2021
Fowler T Blom A Reed M Aquilina A Sayers A Whitehouse M
Full Access

Total hip replacements (THRs) are performed by surgeons at various stages in their training, with varying levels of senior supervision. There is a balance between protecting training opportunities for the next generation of surgeons, while limiting the exposure of patients to unnecessary risk during the training process. The aim of this study was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THR.

We included 603 474 primary THRs recorded in the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man (NJR) between 2003 and 2016 for an indication of osteoarthritis. Exposures were the grade of the surgeon (consultant or trainee), and whether trainees were supervised by a scrubbed consultant or not. Outcomes were all-cause revision, the indication for revision, and the temporal variation in risk of revision (all up to 10 years). Net failure was calculated using Kaplan-Meier analysis and adjusted analyses used Cox regression and flexible parametric survival analysis (adjusted for patient, operative, and unit level factors).

There was no association between surgeon grade and all-cause revision up to 10 years (crude hazard ratio (HR) 0·999, 95% confidence interval (CI) 0.936–1.065; p=0.966); a finding which persisted with adjusted analysis. Adjusted analysis demonstrated an association between trainees operating without supervision by a scrubbed consultant and an increase in all-cause revision (HR 1.100, 95% CI 1.002–1.207; p=0.045). There was an association between the trainee-performed THRs and revision due to instability (crude HR 1.143, 95% CI, 1.007–1.298; p=0.039). However, this was not observed in fully adjusted models, or when trainees were supervised by a scrubbed consultant.

Within the current training system in the United Kingdom, trainees achieve comparable outcomes to consultant surgeons when supervised by a scrubbed consultant. Revision rates are higher when trainees are not supervised by a scrubbed consultant but remain within internationally recognised acceptable limits.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 16 - 16
1 Aug 2021
Gupta V Thomas C Parsons H Metcalfe A Foguet P King R
Full Access

Total hip arthroplasty (THA) is one of the most successful surgical procedures of modern times, however debate continues as to the optimal orientation of the acetabular component and how to reliably achieve this. We hypothesised that functional CT-based planning with patient specific instruments using the Corin Optimised Positioning System (OPS) would provide more accurate component alignment than the conventional freehand technique using 2D templating.

A pragmatic single-centre, patient-assessor blinded, randomised control trial of patients undergoing THA was performed. 54 patients (age 18–70) were recruited to either OPS THA or conventional THA. All patients received a cementless acetabular component. Patients in both arms underwent pre- and post-operative CT scans, and four functional x-rays (standing and seated). Patients in the OPS group had a 3D surgical plan and bespoke guides made. Patients in the conventional group had a surgical plan based on 2D templating x-rays, and the pre-operative target acetabular orientation was recorded by the surgeon. The primary outcome measure was the difference between planned and achieved acetabular anteversion and was determined by post-operative CT scan performed at 6 weeks. Secondary outcome measures included Hip disability and Osteoarthritis Outcome Score (HOOS), Oxford Hip Score (OHS), EQ-5D and adverse events.

In the OPS group, the achieved acetabular anteversion was within 10° of the plan in 96% of cases, compared with only 76% of cases in the conventional group. For acetabular inclination, the achieved position in the OPS group was within 10° of the plan in 96% of cases, compared with in only 84% of cases in the conventional group. These differences were not statistically significant. The clinical outcomes were comparable between the two groups.

Large errors in acetabular orientation appear to be reduced when functional CT-based planning and patient-specific instruments are used compared to the freehand technique, but no statistically significant differences were seen in the difference between planned and achieved angles. Larger studies are needed to analyse this in more detail and to determine whether the reduced numbers of outliers lead to improved clinical outcomes.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 29 - 29
1 Aug 2021
Fishley W Selvaratnam V Carluke I Partington P Reed M Kramer D Wilson M Hubble M Howell J Timperley A Whitehouse S Kassam A Petheram T
Full Access

Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision necessitate removal of all bone cement from the femur. In our two institutions, we have been using a cement-in-cement technique, leaving the distal femoral cement in selected cases for septic hip revision surgery.

Between February 2010 and September 2019, 89 patients with prosthetic hip infection underwent first or single stage procedures leaving the distal femoral cement in situ and performing a cement-in-cement revision. The mean patient age was 72.0 years (24–92). The median time from the last arthroplasty procedure was 29.0 months (1–294).

81 patients underwent revision using a cemented Exeter stem, 7 patients received an articulating spacer, and one patient underwent excision arthroplasty with the distal cement left in situ. Patients received clinical and radiographic follow-up with a mean of 42.8 months (range 11.0–120.1 months). Oxford hip scores were collected from each institution's existing databases.

9 patients (10.1%) died within one year of surgery. No deaths were directly related to joint infection or the surgery. One patient was lost to follow up before one year.

Of the remainder, 7 patients (8.9%) required further procedures for infection and were therefore considered to be treatment failures. 6 patients (7.6%) underwent planned second stage procedures with no recurrence of infection. 7 patients (8.9%) had further surgery for non-infective reasons. The Kaplan-Meier estimate of infection free survival at one year was 93.7% (95% CI 88.4 to 99.0%).

No patients underwent revision for stem loosening. Oxford hip scores were available at over one year postoperatively for 51 patients with a mean score of 30.6, and a mean gain of 11.9.

In our combined cohort of patients, cement-in-cement revision had an infection eradication rate of 91.1%. Patient selection is crucial, and the procedure can only be performed when there is a well-fixed cement mantle. However, when strict criteria are followed, this technique offers potential significant benefits to surgeons performing this challenging surgery, and more importantly the patients undergoing them.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 10 - 10
1 Aug 2021
Jain S Lamb J Townsend O Scott C Kendrick B Middleton R Jones S Board T West R Pandit H
Full Access

Cemented total hip replacement (THR) provides excellent outcomes and is cost-effective. Polished taper-slip (PTS) stems demonstrate successful results and have overtaken traditional composite-beam (CB) stems. Recent reports indicate they are associated with a higher risk of postoperative periprosthetic femoral fracture (PFF) compared to CB stems. This study evaluates risk factors influencing fracture characteristics around PTS and CB cemented stems.

Data were collected for 584 PFF patients admitted to eight UK centres from 25/05/2006-01/03/2020. Radiographs were assessed for Unified Classification System (UCS) grade and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (PTS versus CB). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (OR) with 95% confidence intervals (CI).

Median (IQR) age was 79.1 (72.0–86.0) years, 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The commonest AO/OTA type was spiral (352, 60.3%). Metaphyseal-split fractures occurred only with PTS stems with an incidence of 10.1%. Male gender was associated with a five-fold reduction in odds of a type C fracture (OR 0.22, 95% CI 0.12 to 0.41, p<0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51, 95% CI 3.72 to 24.34, p <0.001) and wedge fracture (OR 3.72, 95% CI 1.16 to 11.95, p <0.05) compared to PTS stems.

This is the largest study investigating PFF characteristics around cemented stems. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal-split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems had higher odds of bending type fractures (transverse and wedge) compared to PTS stems. Biomechanical testing is needed for validation and investigation of modifiable factors which may reduce the risk of unstable fracture patterns requiring complex revision surgery over internal fixation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 11 - 11
1 Aug 2021
Lukic J Rajeev A Tyas B Singisetti K
Full Access

Hip fractures in elderly patients are managed at both major trauma centers (MTC) and trauma units (TU). Previous evidence has demonstrated the importance of early surgery to reduce the morbidity and mortality related to the injury. The aim of this study is to compare the ‘time to theatre' and ‘30 day mortality' in TUs versus MTC in UK.

A retrospective review of prospectively collected data on NHFD was performed. The average ‘time to theatre' in hours and ‘30 day mortality' of all hospitals were analysed between January and December 2018. Further subgroup analysis was done to check for any regional variations; in each instance a Shapiro-Wilk test was used to check for normal distribution, followed by a one-way ANOVA with a Tukey's post hoc test.

Data from 158 hospitals in England (ENG), Wales (WAL) and Northern Ireland (NI) were used; 18 of which were MTC. There were 57,936 operative cases in TUs and 8606 in MTC's. The mean time (hours) to surgery from presentation was 32.51 and 32.64 for TUs and MTC respectively (p=0.513).

There was no significant difference in ‘30 day mortality' (p=0.635) between TUs (6%) and 5.7% MTC's (5.7%), MTC's and TUs in ENG, WAL and NI (p=0.555), and MTC and WAL, NI and the different regions of ENG (p=0.209).

A significant difference was observed, between the regional practice for TUs versus MTC's in ENG, WAL and NI (p=0.001) and between MTC's and TUs in WAL, NI and the different regions of ENG (p=0.001), with patients waiting significantly longer in NI for their procedure (mean=60.25 hours, p=0.001)

There was no significant difference in time to surgery or 30 day mortality between TUs and MTC's, demonstrating comparable hip fracture care, despite MTCs need to prioritise more serious injuries.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 3 - 3
1 Aug 2021
Wignall A Giannoudis V Jimenez A De C Sturdee S Giannoudis P Pandit H Gulati A Palan J
Full Access

In March 2020, the World Health Organisation declared the COVID-19 outbreak a pandemic. Multiple new guidelines were proposed and existing models of social, domestic and hospital care altered. Most healthcare systems were largely unprepared for this and this pandemic has tested their adaptability. This study is aimed at assessing the impact of covid-19 on the demographics, presentation and clinical management of patients with proximal femoral (hip) fractures.

This retrospective multi-centre cohort study compared all patients admitted with hip fractures, between 1st March and 30th May 2019 (Group PC: Pre-Covid) with hip fracture patients admitted over the same time period during the pandemic in 2020 (Group C: Covid). The data was obtained from the hospitals' local and National Hip Fracture Databases. Mortality data was checked with the Office for National Statistics (ONS). Primary outcomes were time to theatre, in-patient length of stay and 30-day mortality.

580 patients were included (304 PC, 276 C). Patient Charlson comorbidity index and Nottingham Hip Fracture scores were broadly similar across the two cohorts. There was a significant reduction in percentage of total hip replacements in Group C (11% to 5%, p=0.006). There was an increase in conservative management in group C (1% to 5%, p=0.002). The time to theatre was significantly delayed in Group C (43.7 hours C versus 34.6 hours PC, p<0.001). Overall length of hospital stay was similar in both groups (16.6 days PC versus 15 days C, p=0.089). 30-day mortality rate in Group C was 9.8% compared to 8.2% in Group PC (p=0.431), but for covid (+) patients it was significantly higher at 38.2% versus 5.8% in covid (−) patients (p<0.001).

This is one of the largest multi-centre comparative cohort study in the literature to date, examining the impact of the covid-19 pandemic on the management of hip fracture patients. Whilst mortality rates were similar in both groups, covid patients were almost seven times more likely to die, reflecting the seriousness of the covid-19 infection and its sequelae in such elderly, vulnerable patients.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 4 - 4
1 Aug 2021
Sahemey R Chahal G Lawrence T
Full Access

Safe and meticulous removal of the femoral cement mantle and cement restrictor can be a challenging process in revision total hip arthroplasty (rTHA). Many proximal femoral osteotomies have been described to access this region however they can be associated with fracture, non-union and revision stem instability. The aim of this study is to report outcomes of our previously unreported vascularised anterior window to the proximal femur.

We report on a cohort of patients who underwent cemented single and staged rTHA at our single institution by the same surgeon between 2012 and 2017 using a novel vascularised anterior window of the femur to extract the cement mantle and restrictor safely under direct vision. We describe our technique, which maintains the periosteal and muscular attachments to the osteotomised fragment, which is then repaired with a polymer cerclage cable. In all revisions a polished, taper slip, long stem Exeter was cemented. Primary outcome measures included the time taken for union and the patient reported WOMAC score.

Thirty-two rTHAs were performed in 29 consecutive patients (13 female, 16 male) with a mean age of 63.4 years (range, 47–88). The indications for revision included infection, aseptic loosening and implant malpositioning. Mean follow up was 5.3 (range, 3.2–8 years). All femoral windows achieved radiographic union by a mean of 7.2 weeks. At the latest point in follow-up the mean WOMAC score was 21.6 and femoral component survivorship was 100%. There were no intraoperative complications or additional revision surgery.

Our proposed vascularised anterior windowing technique of the femur is a safe and reproducible method to remove the distal femoral cement and restrictor under direct vision without the need for perilous instruments. This method also preserves the proximal bone stock and provides the surgeon with the option of cemented stems over uncemented revision implants that predominantly rely on distal fixation.


Greater trochanteric pain syndrome is a painful condition characterised by pain around the greater trochanter usually affecting middle-aged women. The majority of patients will improve with conservative management such as physiotherapy and non-steroidal anti-inflammatory drugs (NSAIDs); however, if this fails then more invasive treatments including corticosteroids and surgery may be required. Platelet-rich plasma (PRP) is an autologous blood product, which has a higher concentration of growth factors postulated to provide enhanced healing and anti-inflammatory properties. The Hip Injections PRP Vs Placebo (HIPPO) trial aims to assess the ability of ultrasound-guided PRP injections to improve symptoms and function in patients with GTPS.

64 patients were enrolled and randomised to either the PRP or placebo (normal saline) treatment arm. Two patients decided to drop out of the trial. Clinical outcomes in both groups were evaluated and compared using the International Hip Outcome Tool-12 (iHOT12), Visual Analogue Scale (VAS) of pain, the modified Harris Hip Score (mHHS) and the presence or absence of complications at 3 and six months. The level of significance was set at p<0.05. Both groups received physiotherapy after the injections.

The mean age was 57.5. There were 6 males and 56 females with M:F ratio of 1:9.3. Both groups were similar in terms of demography and preoperative scores. The iHOT12 score improved from 28.23 to 45.42 at three-months and decreased slightly to 42.44 at six-months in the Placebo group. The iHOT12 in the PRP group improved from 35.51 to 44.47 at three-months and decreased to 39.78 at six-months. Both groups showed improved VAS and mHHS at three-months compared to the baseline with no statistically significant difference between the two groups (p >0.05). The scores decreased at six-months however remained above the baseline. No complications were reported. Gender and age had no effect on outcomes.

Both groups similarly improved from baseline. Physiotherapy can be considered as an important factor in patients' treatment. Further research should be conducted to investigate the role of physiotherapy in the treatment of GTPS.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 27 - 27
1 Aug 2021
Edwards T Keane B Garner A Logishetty K Liddle A Cobb J
Full Access

This study investigates the use of the Metabolic Equivalent of Task (MET) score in a hip arthroplasty population and its ability to capture additional benefit beyond the maximum Oxford Hip Score (OHS).

OHS, EuroQol-5D index (EQ-5D), and the MET were prospectively recorded in 221 primary hip arthroplasty procedures pre-operatively and at 1-year. The distribution was examined reporting the presence of ceiling & floor effects. Validity was assessed correlating the MET with the other scores using Spearman's rank and determining responsiveness using the standardised response mean (SRM). A subgroup of 93 patients scoring 48/48 on the OHS were analysed by age group, sex, BMI and pre-operative MET using the other two metrics to determine if differences could be established despite all scoring identically on the OHS.

117 total hip and 104 hip resurfacing arthroplasty operations were included. Mean age was 59.4 ± 11.3. Post-operatively the OHS and EQ-5D demonstrate significant negatively skewed distributions with ceiling effects of 41% and 53%, respectively. The MET was normally distributed post-operatively with no ceiling effect. Weak-moderate but statistically significant correlations were found between the MET and the other two metrics both pre & post-operatively. Responsiveness was excellent, SRM for OHS: 2.01, EQ-5D: 1.06 and MET: 1.17. In the 48/48 scoring subgroup, no differences were found comparing groups with the EQ-5D, however significantly higher MET scores were demonstrated for patients aged <60 (12.7 vs 10.6, p=0.008), male patients (12.5 vs 10.8, p=0.024) and those with pre-operative MET scores >6 (12.6 vs 11.0, p=0.040).

The MET is normally distributed in patients following hip arthroplasty, recording levels of activity which are undetectable using the OHS. As a simple, valid activity metric, it should be considered in addition to conventional PROMs in order to capture the entire benefit experienced following hip arthroplasty.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 28 - 28
1 Aug 2021
Whelton C Barrow J Singhal R Board T
Full Access

Orthopaedic surgical hoods rely on an intrinsic fan to force clean external air over the wearer and allow potentially contaminated and expired air to flow down and away from the surgical field. Carbon dioxide (CO2) is produced through aerobic metabolism and can potentially accumulate inside the hood. Levels above 2500ppm have been shown to affect cognitive and practical function in flight simulator studies. Maximum Health and Safety Executive (HSE) 8-hour exposure limit is 5000ppm There is a paucity of data on real-world CO2 levels experienced during arthroplasty surgery whilst wearing a hood.

CO2 levels were continuously recorded during 31 elective arthroplasties, both primary and revision. Data was collected for surgeon and assistant. Data was recorded at 0.5Hz throughout the procedure utilising a Bluetooth CO2 detector, worn inside a Stryker Flyte surgical helmet worn with a toga gown. Four surgeons contributed real time data to the study. This data was augmented with experimental data, investigating varying fan speeds and activity levels.

Median operative duration was 82 minutes (range 36–207).

The average CO2 level across all procedures was 2952ppm, with 22 of the cases having a mean above 2500ppm, but none having a mean above 5000ppm.

For each procedure, the time spent above 2500 and 5000 ppm was calculated, with the average being 68.4 % and 5.6% respectively.

The experimental data demonstrated higher CO2 levels with lower fan speed, and at higher activity levels, and levels exceeding 15000 ppm during gentle exercise. During operative cases, low fan speed cases did have a marginally higher mean CO2 value than high fan speed (3033.02 and 2903.56 respectively) but the small numbers of cases (n=10) where this data was captured limit the relevance of this difference.

The use of surgical helmets for elective orthopaedic surgery, can results in CO2 levels regularly rising to a point which may affect cognitive function. This study recommends the use of a higher fan speed where possible to minimise the risk of such CO2 levels, and recommends further research in this area.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 32 - 32
1 Aug 2021
Powell-Bowns M Oag E Ng N Patton J Pandit H Moran M Clement N Scott C
Full Access

The aim of this study is to determine whether fixation, as opposed to revision arthroplasty, can be safely used to treat reducible Vancouver B type fractures in association with a cemented collarless polished tapered femoral stem (the Exeter).

This is a retrospective cohort study of 152 operatively managed consecutive unilateral Vancouver B fractures involving Exeter stems. 130 were managed with open reduction and internal fixation (ORIF) and 22 with revision arthroplasty. Radiographs were assessed and classified by 3 observers. The primary outcome measure was revision of ≥1 component. Kaplan Meier survival analysis was performed. Logistic regression was used to identify risk factors for revision following ORIF. Secondary outcomes included any reoperation, complications, blood transfusion, length of hospital stay and mortality.

Fractures (B1 n=74 (49%); B2 n=50 (33%); and B3 n=28 (18%)) occurred at mean 6.7±10.4 years after primary THA (n=143) or hemiarthroplasty (n=15). Mean follow up was 6.5 ±2.6 years (3.2 to 12.1). Rates of revision and reoperation were significantly higher following revision arthroplasty compared to ORIF for B2 (p=0.001) fractures and B3 fractures (p=0.05). Five-year survival was significantly better following ORIF: 92% (86.4 to 97.4 95%CI) Vs 63% (41.7 to 83.3), p<0.001. No independent predictors of revision following ORIF were identified: fixation of B2 or B3 fractures was not associated with an increased risk of revision. Dislocation was the commonest mode of failure after revision arthroplasty. ORIF was associated with reduced blood transfusion requirement and reoperations, but there were no differences in medical complications, hospital stay or mortality between surgical groups.

When the bone-cement interface was intact and the fracture was anatomically reducible, Vancouver B2 fractures around Exeter stems can be treated with fixation as opposed to revision arthroplasty. Fixation of Vancouver B3 fractures can be performed in frail elderly patients without increasing revision risk.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 34 - 34
1 Aug 2021
Ramavath A Leong J Siney P Kay P Divecha H Board T
Full Access

Principles of bone preservation and restoration of biomechanical alignment should be followed during revision total hip arthroplasty (THA). Where possible, conservative femoral revision techniques and even reconstructive de-escalation involving using primary stems should be considered. This study aims to investigate the outcome of patients who have undergone conservative femoral revision THA in our Institution.

We retrospectively identified patients from our Institution's revision arthroplasty database who had cemented, or un-cemented primary stems implanted during revision THA of a previous stemmed femoral implant. Our primary outcome measure was all-cause re-revision THA with a secondary outcome measure of improvement in Oxford hip score (OHS). Radiographic evidence of stem loosening and post-op complications were recorded.

Between 02/12/2014 to 12/12/2019, there were 226 patients identified with a mean follow up of 2 years (1–5 years). The majority of cases were represented by Paprosky type 1 (63%) and type 2 (25%) femoral defects. There were 45 patients (20%) who underwent impaction bone grafting (IBG) and 43 patients (19%) who had a cement in cement (CinC) femoral revision and cemented primary stem in 137 (60%), 1 uncemented stem with no IBG or CinC revision. Kaplan Meier survival for all-cause re-revision THA was 93.7% (95% CI: 88.3 – 100) at 3 years. The reasons for re-revision included 4 periprosthetic fractures, 4 dislocations, 1 deep infection, 1 loosening of femoral component and 1 loosening of acetabular component. Pre- and post-operative OHS scores were available in 137 hips (60%) with a mean improvement of 13. Radiographic review revealed 7% of cases with evidence of loosening in 1 or more Gruen zones.

Our early results support the use of conservative femoral revision THA techniques where appropriate, with low complication and re-revision rates. Revisions using primary femoral components, where appropriate, should be considered in surgical planning to avoid unnecessary reconstructive escalation.


Computer aided Total Hip Arthroplasty (THA) surgery is known to improve implantation precision, but clinical trials have failed to demonstrate an improvement in survivorship or patient reported outcome measures (PROMs). Our aim was to compare the risk of revision, PROMs and satisfaction rates between computer guided and THA implanted without computer guidance.

We used the National Joint Registry dataset and linked PROMs data. Our sample included THAs implanted for osteoarthritis using cementless acetabular components from a single manufacturer (cementless and hybrid). An additional analysis was performed limiting the sample size to THAs using cementless stems (fully cementless). The primary endpoint was revision (of any component) for any reason. Kaplan Meier survivorship analysis and an adjusted Cox Proportional Hazards model were used.

41683 non computer guided, and 871 (2%) computer guided cases were included in our cementless and hybrid analysis. 943 revisions were recorded in the non-guided and 7 in the computer guided group (adjusted Log-rank test, p= 0.028). Cumulative revision rate at 10 years was 3.88% (95%CI: 3.59 – 4.18) and 1.06% (95%CI: 0.45 – 2.76) respectively. Cox Proportional Hazards adjusted HR: 0.45 (95%CI: 0.21 – 0.96, p=0.038). In the fully cementless group, cumulative revision rate at 10 years was 3.99% (95%CI: 3.62 – 4.38) and 1.20% (95%CI: 0.52 – 3.12) respectively. Cox Proportional Hazards adjusted HR: 0.47 (95%CI: 0.22 – 1.01, p=0.053). There was no statistically significant difference in the 6-month Oxford Hip Score, EQ-5D, EQ-VAS and success rates. Patient Satisfaction (single-item satisfaction outcome measure) was improved in the computer guided group but this finding was limited by a reduced number of responses.

In this single manufacturer acetabular component analysis, the use of computer guided surgery was associated with a significant reduction in the early risk of revision. Causality cannot be inferred in view of the observational nature of the study, and further database and prospective studies are recommended to validate these findings.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 40 - 40
1 Aug 2021
Holleyman R Stamp G Board T Bankes M Khanduja V Malviya A
Full Access

Chondral hip injuries are common secondary to femoroacetabular impingement (FAI). Treatment with arthroscopic procedures including chondroplasty and microfracture is becoming increasingly common but literature is limited to case series at specialist centres. The aim of this study is to compare outcomes of arthroscopic acetabular chondral procedures using the NAHR dataset (UK) which represents the largest series to date.

All adult Arthroscopies recorded in the NAHR from Jan 2012 were available for inclusion. Exclusions included significant arthritis and femoral, complex or revision chondral procedures. Patients completed iHOT-12 & EQ-5D Index pre-operatively, 6 and 12 months. Data was analysed using T-test/ANOVA for between group/within group for continuous variables, chi square test for categorical variables and linear regression model for multivariable analysis.

5,752 patients, 60% female. 27% Chondroplasty, 5% Microfracture, 68% no Chondral Procedure. Maximum acetabular Outerbridge classification 14% Grade 1, 15% Grade 2, 17% Grade 3, 8% Grade 4, 9% no damage, not recorded in 37%. Higher proportion of Cam impingement in association with chondral treatments and a larger proportion of patients with no impingement recorded in group with no chondral procedures. There was a significant improvement versus baseline for all groups in iHOT-12 and EQ-5D Index (p<0.0001) including Grade four Outerbridge. There was significantly greater improvement in pre-operative scores in the chondroplasty group compared to the microfracture group at 6 and 12 months (p<0.05).

Following hip arthroscopy, patients with chondral procedures experienced improved outcome scores despite Outerbridge 4 chondral damage. Presence of cam lesions are more commonly associated with chondral treatments. Good outcomes were maintained up to 12 months for chondral procedures, regardless of age or impingement pathology however pincers improved less and patients over 40 years took longer to see improvement.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 1 - 1
1 Aug 2021
Barrow J Foster A Kenawey M Board T
Full Access

The decision to undertake THA in a child is complex and surgery challenging. Pre-operatively patients' typically have significant pain and mobility restriction. Little is published on the functional gains after THA in this group.

The aim of this study was therefore to measure the impact THA had on the PROMS in our young patients undergoing THA, to determine QoL improvement.

This was a prospective, consecutive cohort study of patients under the age of 17 years undergoing THA by a single surgeon in a tertiary referral centre. Patient electronic notes, radiographs, and PROMS (EQ5D-Y, Oxford Hip Score (OHS) and modified Harris Hip Score (mHHS)) were reviewed.

12 children (8 females and 4 males) underwent THA before their 17th birthday, with 5 undergoing bilateral operations (17 THA total). The mean age was 14.6 years (10.75–16.9) and mean follow-up 1.5 years. Nine of the THA were undertaken for congenital syndromes, 4 for AVN, 2 for Perthe's disease and 1 for dysplasia and idiopathic chondrolysis. The mean pre-operative OHS was 15 (1–33) improving to 31 (19–39) at 6-weeks, 44 (42–46) at a year and 48 (47–48) at 3 years. mHHS improved from a pre-operative mean of 25 (0–56) to 60 (37–92) at 6-weeks, 65 (38–84) at a year and 91 (91) at 3 years. The EQ-VAS mean score pre-operatively was 35 (8–100) improving at 6-weeks to 73 (55–96), 84 (76–96) at a year and 92 (76–100) at 3 years. All patients achieved MCID or higher for OHS. 6 patients were wheelchair users preop. All patients were independent walkers at follow-up. There were no complications.

THA in children is safe and leads to a significant positive impact on QoL as measured with validated PROMS scores. Wheelchair users can reliably gain independent walking. Further follow-up is required understand the long-term outcomes.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 5 - 5
1 Aug 2021
Thompson J Corbett J Bye D Jones A Tissingh E Nolan J
Full Access

The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems.

A systematic literature search was performed adhering to PRISMA criteria. In parallel we performed a retrospective single centre study of Exeter V40 femoral stem prosthetic fractures between April 2003– June 2020.

There are 25 reported cases of such prosthetic fractures confined to small case series and case reports within the literature. We report an additional 19 cases to the literature (mean age 66.3 ± 11.7 years; 12 female [63%]; body mass index 32.9 ± 5.9 kg/m2). The mean time from index procedure to fracture was 7.8 years (2.5–16.3, ±3.6). Exeter V40 stem fracture incidence was 0.27%. Incidence was significantly higher in 125 mm length stems compared to ≥150 mm length stems (1.26% vs 0.13%, respectively, p <0.001) and revision arthroplasty (1.209% vs 0.149%, p <0.001). When comparing different stem length cohorts, 125-mm short-stem were associated with stem body fractures (92% vs 29%, p = 0.0095), earlier time to fracture (6.2 vs 11.0 years, p = 0.0018), younger patient age at time of fracture (62.7 vs 72.6 years old, p = 0.037) and female sex (75% vs 43%, p = 0.33).

This case series in conjunction with the systematic review provides evidence stem morphology plays a role in femoral implant fracture. This complication remains rare, although we report a significantly higher incidence at up to 17 years follow-up than in the literature. As femoral geometries remain the same, increasing BMIs in THR patients should raise concern. Short 125 mm length Exeter V40 stems undoubtedly have a role in restoring anatomy and biomechanics in smaller femoral geometries, although the surgeon has to appreciate the higher risk of stem fracture and the associated predisposing factors which may necessitate meticulous surgical technique and planning.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 6 - 6
1 Aug 2021
Kennedy I Hrycaiczuk A Ng N Sheerins O Patil S Jones B Stark A Meek D
Full Access

Periprosthetic fractures (PPF) of the femur following total hip arthroplasty represent a significant complication with a rising incidence. The commonest subtype is Vancouver B2 type, for which revision to a long uncemented tapered fluted stem is a widely accepted management. In this study we compare this procedure to the less commonly performed cement-in-cement revision.

All patients undergoing surgical intervention for a Vancouver B2 femoral PPF in a cemented stem from 2008 – 2018 were identified. We collated patient age, gender, ASA score, BMI, operative time, blood transfusion requirement, change in haemoglobin (Hb) level, length of hospital stay and last Oxford Hip Score (OHS). Radiographic analysis was performed to assess time to fracture union and leg length discrepancy. Complications and survivorship of implant and patients were recorded.

43 uncemented and 29 cement-in-cement revisions were identified. There was no difference in patient demographics between groups. A significantly shorter operative time was found in the cement-in-cement group, but there was no difference in transfusion requirement, Hb change, or length of hospital stay. OHS was comparable between groups. A non-significant increase in overall complication rates was found in the revision uncemented group, with a significantly higher dislocation rate. Time of union was comparable and there were no non-unions in the cement-in-cement group. A greater degree of stem subsidence was found in the uncemented group. There was no difference in any revision surgery required in either group. Three patients in the uncemented group died in the perioperative period, compared to none in the cement-in-cement group.

With appropriate patient selection, both cement-in-cement and long uncemented tapered stem revision represent appropriate treatment options for Vancouver B2 fractures.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 23 - 23
1 Aug 2021
Holleyman R Sohatee M Bankes M Andrade T McBryde C Board T Conroy J Wilson M Malviya A Khanduja V
Full Access

FAI may cause pain or functional impairment for an individual, as well as potentially resulting in arthritis and degeneration of the hip joint. Results from recent randomised control trials demonstrate the superiority of surgery over physiotherapy in patients with FAI. However, there is paucity of evidence regarding which factors influence outcomes for FAI surgery, most notably on patient reported outcomes measures (PROMs).

Our study looks to explore factors influencing the outcomes for patients undergoing surgery for FAI utilising data from the Non-Arthroplasty Hip Registry.

This study is a retrospective analysis of data collected prospectively via the NAHR database. Patients meeting the inclusion criteria, who underwent surgery between January 2011 and September 2019 were identified and included in the study. Follow-up data was captured in September 2020 to allow a minimum of 12 months follow-up.

Patients consenting to data collection received questionnaires to determine EQ-5D Index and iHOT-12 scores preoperatively and at 6 months, 1, 2- and 5-year follow-up.

Changes in outcome scores were analysed for all patients and sub-analysis was performed looking at the influence of; FAI morphological subtype, age, and sex, on outcome scores.

Our cohort included 4,963 patients who underwent arthroscopic treatment for FAI. There was significant improvement from pre-operative PROMs when compared with those at 6 and 12 months.

Pre-operatively, and at 12-month follow-up, iHOT-12 scores were significantly better for the cam / mixed groups compared to the pincer group (p<0.01).

In multivariable regression analysis, pincer pathology and a high-grade chondral lesion were associated significantly poorer iHOT-12 improvement at 6 and 12 months (p<0.05)

Age (<40 vs >40) demonstrated no statistical significance when considering 12 months outcome scores.

This study demonstrates that hip arthroscopy is an effective treatment for patients with symptomatic FAI and shows statistically significant improvements at 12 months.

The findings of this study are relevant to orthopaedic surgeons who manage young adults with hip pathology. This will help them to; predict which patients may benefit from operative intervention, and better inform patients, when undertaking shared decision making.