Abstract
Aims
The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA).
Methods
A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size.
Results
A total of 116 patients participated, of whom 77 were male. The median ages of the vE-PE 32 mm and 36 mm groups were 65 (interquartile range (IQR) 57 to 67) and 63 years (IQR 56 to 66), respectively, and of the XLPE 32 mm and 36 mm groups were 64 (IQR 58 to 66) and 61 years (IQR 54 to 66), respectively. Mean total head penetration was significantly lower into vE-PE acetabular liner groups than into XLPE acetabular liner groups (-0.219 mm (95% confidence interval -0.348 to -0.090); p = 0.001). There were no differences in wear according to head size, acetabular component migration, or PROMs, except for UCLA. There were no cases of aseptic loosening or failures requiring revision at long-term follow-up.
Conclusion
Significantly lower wear was observed in vE-PE acetabular liners than in XLPE acetabular liners. No difference in wear was observed between different head size or PROMs except for the UCLA at ten years.
Cite this article: Bone Joint J 2023;105-B(10):1052–1059.
Take home message
Head penetration is superior in vitamin E-diffused crosslinked polyethylene (vE-PE) compared to crosslinked polyethylene liners.
Safe use of vE-PE liner at ten-year follow-up potentially reduces the need for revision surgery in the long term.
Introduction
Increases in primary total hip arthroplasties (THAs) over the last decade have required researchers to develop new and more effective methods of reducing wear.1,2 The most commonly used acetabular bearing surface is made of cross-linked polyethylene (XLPE). The aim of using XLPE was to reduce the wear and the risk of osteolysis which was seen with previous ultra-high molecular weight polyethylene (UHMWPE) components.3 Polyethylene (PE) is exposed to radiation to induce cross-linking between the chains of the polyethylene polymers. Radiation creates free radicals prone to oxidative degradation in PE, which are usually removed by the process of annealing or remelting.4 However, annealing or remelting usually reduces resistance to wear, and a compromise between resistance to fatigue crack propagation, wear resistance, and oxidative stability is necessary.4
An alternative solution is to use PE that contains an antioxidant, such as vitamin E (α-tocopherol), to chemically remove free radicals. A cross-linked PE vitamin E (vE-PE) bearing surface should reduce free radicals while maintaining wear resistance.5 Moreover, this material has shown minimal wear rates in experimental settings, and enhanced resistance to fatigue crack propagation and oxidation.6,7 Short-term follow-up studies have either favoured vE-PE or shown similar head penetration to XLPE. However, it is unclear whether these results will be maintained into the longer term.8-12
Evidence on the effect of different head sizes on vE-PE wear remains sparse.2,13,14 The nature of randomized controlled trials (RCTs) makes it difficult to measure long-term outcomes. Revision rate and PE wear are associated variables. While PE wear can be estimated using a radiostereometric analysis (RSA), absolute risk of revision cannot be measured with certainty due to the long-term success of THA, high drop out rates with long-term studies and low overall revision rates.15,16
The primary aim of this multi-arm RCT was to investigate acetabular liner component wear related to its material and head size as measured by head penetration. Specifically, the objectives were to examine head penetration between vE-PE and XLPE liners in an uncemented acetabular component, and between 32 mm and 36 mm femoral heads, with ten-year follow-up. We have previously reported the results at five years of follow-up.17 The secondary aim was to compare acetabular component migration between the different liners and head sizes. Furthermore, we compared patient-reported outcome measures (PROMs) between the different head sizes. We hypothesized that vE-PE liners would show significantly less wear than XLPE liners after ten years.
Methods
Trial design
This study was a patient-blinded, multi-arm, 2 × 2 factorial RCT. The study was initially designed for 100 patients, with recruitment between May 2009 and April 2011 at two regional hospitals in Denmark (Odense University Hospital and Middelfart Hospital). This RCT is reported according to the Consolidated Standards of Reporting Trials guidelines for multi-arm RCTs.18
Patients
The patients included were aged between 40 and 70 years, had primary osteoarthritis of the hip, and were able to follow the proposed rehabilitation programme. Patients were excluded if they had dysplasia (centre-edge angle < 20°), severe anteversion of the femoral neck, previous radiotherapy, were unable to participate in the rehabilitation programme, had malignancy, femoral cerclage during surgery, or required screw augmentation to secure fixation of the acetabular shell. Patients requiring an acetabular shell with a diameter < 54 mm were also excluded, due to the need for adequate space to accommodate the 36 mm femoral head size. By implementing these exclusion criteria, we aimed to create a more focused and controlled study population, allowing for a more reliable evaluation of the factors under investigation.
Intervention
This was a 2 × 2 study and the patients were blinded to which liner and head size they received. A patient was assigned to one of four intervention groups: 1) XLPE acetabular liner (ArComXL; Zimmer Biomet, USA) with 32 mm head (XLPE, 32 mm); 2) XLPE with a 36 mm head (XLPE, 36 mm); 3) vE-PE acetabular liner (E1; Zimmer Biomet) with a 32 mm head (vE-PE, 32 mm); or 4) vE-PE with a 36 mm head (vE-PE, 36 mm).
Patients undergoing THA received plasma-sprayed, porous-coated uncemented acetabular components (Exceed ABT; Zimmer Biomet) and uncemented, porous-coated femoral components (Bi-Metric; Zimmer Biomet) with cobalt-chrome (Co-Cr) femoral heads (Zimmer Biomet). The posterior approach was used in all patients in the lateral position. The proximal femur and periacetabular bone was marked with ten tantalum beads (diameter = 0.8 mm). The patients received antibiotics and tranexamic acid during surgery. Rehabilitation started on the day of the operation, with pain management and discharge completed according to standard procedures.
Outcomes and PROMs
We defined the primary endpoint, wear, as the total proximal head penetration into the liner as measured by RSA after ten years.17 The secondary endpoints were acetabular component migration and PROMs: the EuroQol five-dimension questionnaire (EQ-5D), which assesses general health and is used with the Danish time trade-off value set,19,20 36-Item Short-Form Health Survey (SF-36), which sums to a mental and physical health summary,21 Harris Hip Score (HHS), which ranges from 0 to 100 with higher scores corresponding to better outcomes, and assesses pain, function, deformity, and movement,22,23 and University of California, Los Angeles (UCLA) activity scale, which measures physical activity and uses a Likert-esque scale from 0 to 10.24 These PROMs were administered postoperatively and at each follow-up.
Radiostereometric analysis
RSA was performed in accordance with the RSA guidelines at baseline (within seven days after surgery) and at three, 12, 24, 60, 84, and 120 months.16 X-rays were produced with two synchronized, ceiling-mounted, and mobile roentgen tubes angled at approximately 35° to each other; the exposure was set to 130 kV and 20 mA. The two X-rays were performed simultaneously while the patient was in supine position with the hip situated over a uniplanar calibration cage (Cage 43; RSA Biomedical, Sweden). All patient radiographs were analyzed with model-based RSA (MBRSA; version 4.2, RSAcore, Netherlands) using contour detection software.
The RSA precision was calculated from double examinations and was comparable to those previously reported in our previous follow-up study.17 Examinations with a mean rigid body fitting error > 0.350 mm and a condition number > 135 were rejected according to the RSA guidelines.16
Adverse events
An investigation using the Danish Regional Patient Registry was performed on each patient at their ten-year follow-up to identify any reported parameters or indications for revision hip arthroplasty.
Sample size
This parallel 2 × 2 factorial design trial was designed to investigate whether vE-PE liners showed lower wear than XLPE liners. The risk of type 1 error was set to 5% with the power of 80%. Wear was expected to decrease from 0.05 mm/year with XLPE to 0.0005 mm/year with vE-PE, and the minimal clinically relevant difference was set at 0.05 mm/year. Based on these parameters, we required 15 hips for each group. A total of 25 patients were included per arm, to account for dropouts and secondary exclusions.17
Randomization
Lots were randomly computer-generated, and placed in sealed envelopes in two blocks: one with 100 lots of 25 per group, and another with 28 lots of seven per group. This was necessary due to over-recruitment at the participating hospitals. The study was blinded to patients, and the envelopes were opened immediately before the acetabular liners were inserted.
Registration and ethics
Oral and written informed consent was obtained from all patients, who could withdraw their consent at any time. This trial was approved by the Regional Committees on Health Research Ethics for Southern Denmark (S-20080151) and the Danish Data Protection Agency (14/35949 and 18/31287), and complied with the Declaration of Helsinki.25 This trial was registered at ClinicalTrials.gov (NCT02196792).
Statistical analysis
The patients were divided into intention-to-treat (ITT) and per-protocol (PP) groups. PP was defined as patients in the ITT group who were present at all RSA follow-ups. The mean and standard deviation (SD) or median and interquartile ranges (IQRs) were used as descriptive statistics. The statistical analysis followed an analysis protocol previously reported on ClinicalTrials.gov (NCT02196792). Mixed-effects analyses were performed using the restricted maximum likelihood method.26 We classified acetabular component liner material, head size, and time as fixed effects and patients as random effects. In addition, we included interactions between material and head size with time. A p-value < 0.05 was considered statistically significant. PROM analyses were adjusted to account for baseline values. We tested the mixed-effect estimates for significance using a Wald test. Independent statisticians managed all statistics using Stata v. 17 (StataCorp, USA).
Results
Recruitment
A total of 220 patients were considered eligible for this study, of whom 93 were excluded for the following reasons (Figure 1): four required supplementary acetabular screws, 26 received an acetabular component < 54 mm, five received other manufacturers’ components, one experienced surgical complications, and 57 were excluded due to other reasons. Overall, 11 of the 127 patients who underwent randomization did not receive their allocated intervention. They were excluded for the following reasons: five underwent screening failure, one received other components, four required acetabular screws, and one had a dislocation during surgery and received other components.
Fig. 1
In total, 116 patients underwent both the intended intervention and randomization. At the ten-year timepoint, 34 were lost to follow-up, and 82 remained enrolled. Their baseline data are presented in Table I.
Table I.
Characteristic | vE-PE, 32 mm | vE-PE, 36 mm | XLPE, 32 mm | XLPE, 36 mm |
---|---|---|---|---|
Total, n | 24 | 29 | 30 | 33 |
Male sex, n (%) | 19 (79) | 20 (69) | 19 (63) | 19 (58) |
Median age, yrs (IQR) | 65 (57 to 67) | 63 (56 to 66) | 64 (58 to 66) | 61 (54 to 66) |
Mean BMI, kg/m2 (range) | 28 (22 to 40) | 29 (22 to 36) | 28 (20 to 41) | 27 (21 to 38) |
ASA grade, n (%) | ||||
I | 8 (31) | 10 (33) | 8 (27) | 13 (41) |
II | 14 (54) | 14 (47) | 15 (50) | 8 (25) |
III | 1 (4) | 1 (3) | 1 (3) | 1 (3) |
Data not available | 3 (12) | 5 (17) | 6 (20) | 11 (31) |
Median blood loss, ml (IQR) | 450 (225 to 550) | 300 (200 to 600) | 350 (300 to 400) | 350 (225 to 400) |
Median duration of anaesthesia, mins (IQR) | 90 (75 to 105) | 80 (66 to 95) | 75 (65 to 84) | 83 (71 to 99) |
Median days hospitalized (IQR) | 3 (3 to 3) | 3 (2 to 3) | 3 (2 to 4) | 3 (3 to 5) |
Mean Harris Hip Score (range) | 47 (29 to 80) | 49 (18 to 81) | 50 (13 to 74) | 44 (21 to 74) |
Median UCLA activity scale (IQR) | 6 (4 to 7) | 6 (4 to 8) | 6 (5 to 7) | 5 (4 to 7) |
Median EQ-5D index (IQR) | 0.72 (0.66 to 0.72) | 0.66 (0.59 to 0.72) | 0.72 (0.57 to 0.72) | 0.72 (0.59 to 0.72) |
Median EQ-5D VAS (IQR) | 65 (46 to 83) | 60 (40 to 70) | 70 (50 to 79) | 75 (60 to 90) |
Mean SF-36 PCS (range) | 40 (29 to 52) | 37 (24 to 54) | 37 (21 to 48) | 39 (20 to 56) |
Mean SF-36 MCS (range) | 55 (37 to 65) | 52 (29 to 66) | 51 (29 to 64) | 55 (35 to 67) |
-
Permission to reproduce this table was granted by author K. Kjærgaard.17
-
ASA, American Society of Anesthesiologists; EQ-5D, EuroQoL five dimension three-level questionnaire; IQR, interquartile range; MCS, mental component summary; PCS, physical component summary; SF-36, 36-Item Short-Form Health Survey; UCLA, University of California, Los Angeles; VAS, visual analogue scale; vE-PE, vitamin E-diffused crosslinked polyethylene liners; XLPE, cross-linked polyethylene liners.
Head penetration
We found significantly lower mean total head penetration into vE-PE than into XLPE (-0.219 mm (95% confidence interval (CI) -0.348 to -0.090); p = 0.001) at ten-year follow-up (Figure 2, Table II).
Fig. 2
Table II.
Outcome | vE-PE (95% CI) | XLPE (95% CI) | vE-PE vs XLPE (95% CI) | p-value |
---|---|---|---|---|
Comparison between vE-PE and XLPE | ||||
Total head penetration (mm) | -0.012 (-0.114 to 0.089) | 0.207 (0.087 to 0.326) | -0.219 (-0.348 to -0.090) | 0.001 |
Head penetration rate, mm/yr | ||||
0 to 3 mths | 0.141 (-0.236 to 0.517) | -0.277 (-0.643 to 0.090) | 0.417 (-0.108 to 0.943) | 0.120 |
3 mths to 1 yr | -0.066 (-0.194 to 0.062) | -0.008 (-0.134 to 0.117) | -0.058 (-0.237 to 0.121) | 0.527 |
1 to 2 yrs | -0.067 (-0.161 to 0.027) | 0.025 (-0.065 to 0.115) | -0.091 (-0.222 to 0.039) | 0.527 |
2 to 5 yrs | -0.002 (-0.034 to 0.031) | -0.027 (-0.057 to 0.002) | 0.026 (-0.018 to 0.070) | 0.250 |
5 to 7 yrs | 0.056 (0.005 to 0.107) | -0.013 (-0.058 to 0.031) | 0.069 (0.001 to 0.137) | 0.046 |
7 to 10 yrs | -0.004 (-0.040 to 0.031) | -0.016 (-0.047 to 0.016) | 0.011 (-0.036 to 0.059) | 0.644 |
Secondary outcomes | ||||
Cup migration, mm | 0.155 (-0.020 to 0.329) | 0.363 (0.159 to 0.568) | -0.209 (-0.441 to 0.023) | 0.078 |
Comparison between 32 and 36 mm | 32 mm (95% CI) | 36 mm (95% CI) | 32 mm vs 36 mm (95% CI) | p-value |
Total head penetration, mm | 0.076 (-0.025 to 0.176) | 0.140 (0.018 to 0.263) | -0.065 (-0.195 to 0.066) | 0.332 |
Head penetration rate, mm/yr | ||||
0 to 3 mths | -0.067 (-0.446 to 0.312) | -0.078 (-0.450 to 0.294) | 0.011 (-0.520 to 0.542) | 0.968 |
3 mths to 1 yr | -0.035 (-0.165 to 0.095) | -0.039 (-0.165 to 0.087) | 0.004 (-0.177 to 0.186) | 0.962 |
1 to 2 yrs | 0.034 (-0.062 to 0.130) | -0.065 (-0.156 to 0.025) | 0.050 (-0.016 to 0.116) | 0.962 |
2 to 5 yrs | -0.039 (-0.071 to -0.007) | 0.006 (-0.025 to 0.037) | -0.045 (-0.089 to -0.000) | 0.048 |
5 to 7 yrs | 0.004 (-0.046 to 0.054) | 0.027 (-0.019 to 0.074) | -0.024 (-0.092 to 0.045) | 0.498 |
7 to 10 yrs | 0.014 (-0.021 to 0.049) | -0.033 (-0.065 to -0.000) | 0.047 (-0.001 to 0.095) | 0.053 |
Secondary outcomes | ||||
Cup migration | 0.235 (0.061 to 0.408) | 0.310 (0.104 to 0.516) | -0.075 (-0.307 to 0.156) | 0.523 |
Harris Hip Score | 31 (24 to 37) | 36 (29 to 44) | -6 (-14 to 2) | 0.139 |
UCLA activity scale | 0.6 (-0.1 to 1.4) | 1.8 (0.9 to 2.7) | -1.2 (-2.1 to -0.2) | 0.017 |
EQ-5D index | 0.17 (0.10 to 0.23) | 0.16 (0.09 to 0.22) | 0.01 (-0.06 to 0.08) | 0.806 |
EQ-5D VAS | 12 (4 to 19) | 10 (2 to 18) | 2 (-7 to 10) | 0.715 |
SF-36 PCS | 10 (7 to 12) | 10 (6 to 14) | -1 (-4 to 3) | 0.777 |
SF-36 MCS | 1 (-2 to 4) | 3 (-1 to 6) | -1 (-5 to 2) | 0.439 |
-
CI, confidence interval; EQ-5D, EuroQol five-dimension questionnaire; IQR, interquartile range; MCS, mental component summary; PCS, physical component summary; SF-36, 36-Item Short-Form Health Survey; UCLA, University of California, Los Angeles; VAS, visual analogue scale; vE-PE, vitamin E-diffused highly cross-linked ultra-high-molecular weight polyethylene liner; XLPE, medium cross-linked polyethylene liner.
However, penetration did not differ significantly between 32 mm and 36 mm head sizes: -0.065 mm (95% CI -0.195 to 0.066; p = 0.332; Figure 2 and Table II). The PP analysis showed similar results (Supplementary Table i).
Acetabular component migration
Acetabular component migration did not differ significantly between vE-PE and XLPE groups. The difference was -0.209 mm (95% CI -0.441 to 0.023; p = 0.078) (Table II). The head size of 32 mm and 36 mm femoral heads did not influence component migration. The difference was -0.075 mm (95% CI -0.307 to 0.156; p = 0.523) (Table II). However, acetabular component migration up to the final follow-up differed significantly from baseline measurements within each liner and head size group. However, migration appeared to stabilize after 12 months (Supplementary Figure a).
PROMs
PROMs did not differ significantly between 32 and 36 mm head size groups, except for the UCLA activity scale, which was 1.2 points higher in the 36 mm group than in the 32 mm group (-1.2 (95% CI -2.1 to -0.2); p = 0.017) (Table II). Nevertheless, individual within-head size group PROM improvements were all significantly better than baseline at the ten-year follow-up, except for the UCLA activity scale in the 32 mm head size group.
Adverse events
One patient in the 36 mm XLPE group underwent revision two days after surgery due to dislocation and was excluded from the trial.
Discussion
To our knowledge, this study has the longest follow-up period (ten years) comparing the wear outcomes of vE-PE and XLPE acetabular component liners. We found that total head penetration was significantly lower for vE-PE liners compared to XLPE liners at the ten-year follow-up (p = 0.001). Our results support our hypothesis that vE-PE liners would show significantly lower wear than XLPE liners. These findings show that vitamin E prevents the reduced wear resistance seen in XLPE liners due to processes such as annealing or remelting.4 Furthermore, we did not observe a significant influence of head size on wear. This finding aligns with previous studies that demonstrated that total head penetration and wear rates are independent from femoral head size.27-29
No patients experienced aseptic loosening, and only one underwent revision due to dislocation two days after surgery. Given that the THA lifespan is usually 20 years,2,14 the sample size was small, and the wear rate was low, other revisions would have been unlikely. Moreover, wear in this study was below the reported osteolysis threshold of 0.1 mm/year,15 except for the zero- to three-month results. This exception could be attributed to the early creep phase that is present during the first months after surgery.30
Numerous studies have examined the effects of vitamin E on PE wear. Six of the most recent studies, with the same RSA technique as this study, compared wear vE-PE and XLPE acetabular component liners, but came to different conclusions.8-12,17 Two reported no difference in wear at five and seven years, while four reported lower wear in vE-PE liners at two to five years. These reports show that there is no established consensus regarding whether vE-PE liners show better wear resistance than XLPE liners. These reported differences could be explained by sources of systematic error such as biological variability, ‘noise’ within the software, the in-hospital location, and the correct placement of patients before performing RSA.
Studies have shown that acetabular component sizes ≥ 58 mm and inclination angles ≥ 45° are correlated with PE wear.31,32 No similar studies to ours have investigated inclination angle or the influence of these parameters, and only two reported the acetabular component size used.10,17 One study investigated highly XLPE with vitamin E and UHMWPE components, and found no significant difference in PE wear with increasing acetabular component inclination angle.33 Therefore, PE wear relative to acetabular component inclination angle might explain differences in results over the same period.
This study confirmed our previous report’s conclusion, at five-year review, that a longer follow-up was needed to evaluate actual differences in wear.17 A significant difference in wear between vE-PE and XLPE liners was found at seven and ten years (Figure 2a). There was a slight decrease in wear from the fifth year in the vE-PE liner group at both seven and ten years. This decrease in wear represents the ITT results and potentially reflects the loss of follow-up subjects at ten years, of whom 75% were in the vE-PE group. Another possible explanation is the challenge of measuring penetration of the acetabular liner material that displays wear close to zero. However, the wear in the PP population (Supplementary Figure b) shows a more flat, horizontal, linear trend with less deviation. This pattern supports the assumption that dropouts explain the negative wear rate in vE-PE between seven and ten years.
Migration analysis showed no significant difference in wear between acetabular liner materials and head sizes. These findings confirm previous data showing that implants which are stable for two years do not progress to clinical loosening.34
All groups showed PROM improvement from baseline with no significant differences between head sizes, except for the UCLA activity scale. While a minimal clinically important difference in the UCLA activity scale has not yet been established for THA, a one-level increase is expected to provide a meaningful clinical difference.35 None of the other PROMs were significant, and we do not think the UCLA activity scale has any clinical significance, as the study was not designed to adjust for multiple comparisons, and because the UCLA activity scale was not the primary outcome of this trial.35
The only differences in the intervention groups were head size and acetabular liner material; all other parameters were identical between the groups. We believe that our patients were representative of most THA patients, considering that 80% of patients undergoing THA is for primary osteoarthritis.2 The primary outcome was assessed using a standardized protocol.16 We performed ITT and PP analyses to strengthen our results by reducing potential biases due to differential dropouts. Both analyses were statistically significant and favoured vE-PE over XLPE. Moreover, the sample size calculation was consistent with similar RCTs.9,10
While we included a randomization process and used the gold-standard RSA,36 the most sensitive and accurate measurement technique, this study still had limitations. The acetabular liners did not contain implanted tantalum beads. Therefore, only the model-based RSA method was used, which might have compromised our outcome accuracy. However, studies have shown that the marker method is clinically inconsequential and that model-based method’s precision is sufficient.37 This study’s single-blinded, randomized nature permitted the surgeons to contribute a conscious or unconscious observer bias while performing the surgery with either acetabular liner type. In addition, it is important to note that all surgeries in this study were performed by three highly experienced orthopaedic surgeons (OO, CH, SO). Further, this study’s insufficient and decentralized trial organization impacted patient recruitment and randomization. While this trial was designed for 100 patients, 127 were randomized, and additional randomization envelopes had to be generated. These measures were implemented upon the realization by the involved parties that an excess number of patients had provided consent to participate. This unintentional increase demonstrated a lack of administrative coordination between its different hospital sites. Finally, 34 patients were lost to follow-up after ten years, which is expected in any long-term follow-up study. We expected the loss to follow-up to occur at random, as no group of patients suffered from any clinical complications or side effects associated with a requirement for revision surgery.
In summary, this ten-year RCT found a significant difference in wear between vE-PE and XLPE acetabular liner components that favoured vE-PE, but no significant differences in wear between 32 mm and 36 mm head sizes. All PROMs did not differ significantly between head sizes, except for the UCLA activity scale, and all PROMs reported improvements from the baseline. While we found that vE-PE liners provided superior performance with reduced head penetration compared to XLPE liners, longer follow-up is still needed to determine any significant clinical differences that may still arise.
References
1. Kurtz SM . UHMWPE Biomaterials Handbook . 3rd ed . Oxford, UK : Elsevier , 2015 : 293 – 304 . Google Scholar
2. No authors listed . (Danish Hip Arthroplasty Register National Annual Report for 2021) , Danish Hip Arthroplasty Register . 2021 . http://danskhoftealloplastikregister.dk/wp-content/uploads/2022/07/DHR-aarsrapport-2021_Udgivet-2022_offentliggjort-version-1.pdf ( date last accessed 27 July 2023 ). (Report in Danish). Google Scholar
3. Hopper RH , Ho H , Sritulanondha S , Williams AC , Engh CA . Otto Aufranc Award: Crosslinking reduces THA wear, osteolysis, and revision rates at 15-year followup compared with noncrosslinked polyethylene . Clin Orthop Relat Res . 2018 ; 476 ( 2 ): 279 – 290 . Crossref PubMed Google Scholar
4. Atwood SA , Van Citters DW , Patten EW , Furmanski J , Ries MD , Pruitt LA . Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene . J Mech Behav Biomed Mater . 2011 ; 4 ( 7 ): 1033 – 1045 . Crossref PubMed Google Scholar
5. Bracco P , Oral E . Vitamin E-stabilized UHMWPE for total joint implants: a review . Clin Orthop Relat Res . 2011 ; 469 ( 8 ): 2286 – 2293 . Crossref PubMed Google Scholar
6. Oral E , Rowell SL , Muratoglu OK . The effect of alpha-tocopherol on the oxidation and free radical decay in irradiated UHMWPE . Biomaterials . 2006 ; 27 ( 32 ): 5580 – 5587 . Crossref PubMed Google Scholar
7. Oral E , Wannomae KK , Hawkins N , Harris W , Muratoglu O . Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear . Biomaterials . 2004 ; 25 ( 24 ): 5515 – 5522 . Crossref PubMed Google Scholar
8. Thoen PS , Nordsletten L , Pripp AH , Röhrl SM . Results of a randomized controlled trial with five-year radiostereometric analysis results of vitamin E-infused highly crosslinked versus moderately crosslinked polyethylene in reverse total hip arthroplasty . Bone Joint J . 2020 ; 102-B ( 12 ): 1646 – 1653 . Crossref PubMed Google Scholar
9. Nebergall AK , Greene ME , Laursen MB , Nielsen PT , Malchau H , Troelsen A . Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis . Bone Joint J . 2017 ; 99-B ( 5 ): 577 – 584 . Crossref PubMed Google Scholar
10. Shareghi B , Johanson P-E , Kärrholm J . Wear of vitamin E-infused highly cross-linked polyethylene at five years . J Bone Joint Surg Am . 2017 ; 99-A ( 17 ): 1447 – 1452 . Crossref PubMed Google Scholar
11. Galea VP , Rojanasopondist P , Laursen M , Muratoglu OK , Malchau H , Bragdon C . Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis . Bone Joint J . 2019 ; 101-B ( 7 ): 760 – 767 . Crossref PubMed Google Scholar
12. Sköldenberg OG , Rysinska AD , Chammout G , et al. A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty . Bone Joint J . 2019 ; 101-B ( 10 ): 1192 – 1198 . Crossref PubMed Google Scholar
13. Tarasevicius S , Robertsson O , Kesteris U , Kalesinskas RJ , Wingstrand H . Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: A sonographic and radiographic study of 39 patients . Acta Orthop . 2008 ; 79 ( 4 ): 489 – 493 . Crossref PubMed Google Scholar
14. No authors listed . The New Zealand Joint Registry twenty-two year report January 1999 to December 2020 . New Zealand Joint Registry . 2021 . https://www.nzoa.org.nz/sites/default/files/NZJR_22_Year_Report_Final.pdf ( date last accessed 20 July 2023 ). Google Scholar
15. Dumbleton JH , Manley MT , Edidin AA . A literature review of the association between wear rate and osteolysis in total hip arthroplasty . J Arthroplasty . 2002 ; 17 ( 5 ): 649 – 661 . Crossref PubMed Google Scholar
16. Valstar ER , Gill R , Ryd L , Flivik G , Börlin N , Kärrholm J . Guidelines for standardization of radiostereometry (RSA) of implants . Acta Orthop . 2005 ; 76 ( 4 ): 563 – 572 . Crossref PubMed Google Scholar
17. Kjærgaard K , Ding M , Jensen C , et al. Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial . Bone Joint J . 2020 ; 102-B ( 10 ): 1303 – 1310 . Crossref PubMed Google Scholar
18. Juszczak E , Altman DG , Hopewell S , Schulz K . Reporting of multi-arm parallel-group randomized trials: Extension of the CONSORT 2010 Statement . JAMA . 2019 ; 321 ( 16 ): 1610 – 1620 . Crossref PubMed Google Scholar
19. Herdman M , Gudex C , Lloyd A , et al. Development and preliminary testing of the new five-level version of EQ-5D (EQ-5D-5L) . Qual Life Res . 2011 ; 20 ( 10 ): 1727 – 1736 . Crossref PubMed Google Scholar
20. Wittrup-Jensen KU , Lauridsen J , Gudex C , Pedersen KM . Generation of a Danish TTO value set for EQ-5D health states . Scand J Public Health . 2009 ; 37 ( 5 ): 459 – 466 . Crossref PubMed Google Scholar
21. Ware JE . SF-36: Physical and Mental Health Summary Scales: A User’s Manual . Vol 1 . Boston, Massachusetts, USA : Health Institute , 1994 . Google Scholar
22. Harris WH . Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation . J Bone Joint Surg Am . 1969 ; 51-A ( 4 ): 737 – 755 . PubMed Google Scholar
23. Söderman P , Malchau H . Is the Harris hip score system useful to study the outcome of total hip replacement? Clin Orthop Relat Res . 2001 ; 384 : 189 – 197 . Crossref PubMed Google Scholar
24. Zahiri CA , Schmalzried TP , Szuszczewicz ES , Amstutz HC . Assessing activity in joint replacement patients . J Arthroplasty . 1998 ; 13 ( 8 ): 890 – 895 . Crossref PubMed Google Scholar
25. World Medical Association . World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects . JAMA . 2013 ; 310 ( 20 ): 2191 – 2194 . Crossref PubMed Google Scholar
26. Kirkwood BR , Sterne JAC . Essential Medical Statistics . 2nd ed . Hoboken : Wiley-Blackwell , 2003 . Google Scholar
27. Lindalen E , Thoen PS , Nordsletten L , Høvik Ø , Röhrl SM . Low wear rate at 6-year follow-up of vitamin E-infused cross-linked polyethylene: a randomised trial using 32- and 36-mm heads . HIP Int . 2019 ; 29 ( 4 ): 355 – 362 . Crossref PubMed Google Scholar
28. Tsikandylakis G , Mortensen KRL , Gromov K , Mohaddes M , Malchau H , Troelsen A . Does the use of the largest possible metal head increase the wear of vitamin E-doped cross-linked polyethylene? Two-year results from a randomized controlled trial . Bone Joint J . 2021 ; 103-B ( 7 ): 1206 – 1214 . Crossref PubMed Google Scholar
29. Fransen BL , Bengoa FJ , Neufeld ME , Sheridan GA , Garbuz DS , Howard LC . Thin highly cross-linked polyethylene liners combined with large femoral heads in primary total hip arthroplasty show excellent survival and low wear rates at a mean follow-up of 12.8 years . Bone Joint J . 2023 ; 105-B ( 1 ): 29 – 34 . Crossref PubMed Google Scholar
30. Glyn-Jones S , McLardy-Smith P , Gill HS , Murray DW . The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis . J Bone Joint Surg Br . 2008 ; 90-B ( 5 ): 556 – 561 . Crossref PubMed Google Scholar
31. Little NJ , Busch CA , Gallagher JA , Rorabeck CH , Bourne RB . Acetabular polyethylene wear and acetabular inclination and femoral offset . Clin Orthop Relat Res . 2009 ; 467 ( 11 ): 2895 – 2900 . Crossref PubMed Google Scholar
32. Tian J-L , Sun L , Hu R-Y , Han W , Tian X-B . Correlation of cup inclination angle with liner wear for metal-on-polyethylene in hip primary arthroplasty . Orthop Surg . 2017 ; 9 ( 2 ): 186 – 190 . Crossref PubMed Google Scholar
33. Rochcongar G , Remazeilles M , Bourroux E , et al. Reduced wear in vitamin E-infused highly cross-linked polyethylene cups: 5-year results of a randomized controlled trial . Acta Orthop . 2021 ; 92 ( 2 ): 151 – 155 . Crossref PubMed Google Scholar
34. Pijls BG , Nieuwenhuijse MJ , Fiocco M , et al. Early proximal migration of cups is associated with late revision in THA . Acta Orthopaedica . 2012 ; 83 ( 6 ): 583 – 591 . Crossref PubMed Google Scholar
35. Canfield M , Savoy L , Cote MP , Halawi MJ . Patient-reported outcome measures in total joint arthroplasty: defining the optimal collection window . Arthroplast Today . 2020 ; 6 ( 1 ): 62 – 67 . Crossref PubMed Google Scholar
36. Valstar ER , H S Gill R . Radiostereometric analysis in orthopaedic surgery: editorial comment . Clin Orthop Relat Res . 2006 ; 448 : 2 . Crossref PubMed Google Scholar
37. Nebergall AK , Rader K , Palm H , Malchau H , Greene ME . Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner . Acta Orthop . 2015 ; 86 ( 5 ): 563 – 568 . Crossref PubMed Google Scholar
Author contributions
J. A. N. El-Sahoury: Conceptualization, Data curation, Formal analysis, Investigation, Project administration, Validation, Visualization, Writing – original draft, Writing – review & editing.
K. Kjærgaard: Formal analysis, Supervision, Writing – review & editing.
O. Ovesen: Investigation, Methodology, Writing – review & editing.
C. Hofbauer: Investigation, Methodology, Writing – review & editing.
S. Overgaard: Funding acquisition, Investigation, Methodology, Project administration, Supervision, Writing – review & editing.
M. Ding: Investigation, Methodology, Project administration, Supervision, Writing – review & editing.
Funding statement
The authors disclose receipt of the following financial or material support for the research, authorship, and/or publication of this article: a grant from Zimmer Biomet covered the cost of study materials and a research nurse, moreover the role of the Funder/Sponsor had the rights to comment on the manuscript but with no changes.
ICMJE COI statement
The authors declare no conflict of interest. J. A. N. El-Sahoury reports an undergraduate scholarship from Odense University Hospital, and reports support to travel to Lisbon, Portugal, to present the data as part of the scientific content of the 23rd EFORT Annual Congress from 22 to 24 June 2022. S. Overgaard reports a personal payment from Johnson & Johnson for a lecture, and institutional payments for lectures and work as a course moderator from Heraeus, unrelated to this study.
Data sharing
The datasets generated and analyzed in the current study are not publicly available due to data protection regulations. Access to data is limited to the researchers who have obtained permission for data processing. Further inquiries can be made to the corresponding author.
Acknowledgements
We thank Annie Gam-Pedersen, the project nurse, for her essential role in patient recruitment. We also extend our appreciation to statisticians Frank Sjøberg Kjeldsen and Sören Möller from Open Patient data Explorative Network (OPEN), Odense University Hospital (OUH), for their invaluable assistance with statistical analyses. Special thanks to medical student David Karimi from SDU for his help with data collection. Their contributions were vital to the successful completion of this study.
Ethical review statement
This trial was approved by The Regional Committees on Health Research Ethics for Southern Denmark (S-20080151) and The Danish Data Protection Agency (14/35949 and 18/31287) and complied with the Declaration of Helsinki.
Open access funding
The authors confirm that the open access fee was covered by their study budget.
Open access statement
This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/
Trial registration number
The trial was registered at ClinicalTrials.gov (NCT02196792).