Advertisement for orthosearch.org.uk
Results 1 - 50 of 129
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1607 - 1611
1 Dec 2009
Stufkens SAS Knupp M Lampert C van Dijk CN Hintermann B

We have compared the results at a mean follow-up of 13 years (11 to 14) of two groups of supination-external rotation type-4 fractures of the ankle, in one of which there was a fracture of the medial malleolus and in the other the medial deltoid ligament had been partially or completely ruptured. Of 66 patients treated operatively between 1993 and 1997, 36 were available for follow-up. Arthroscopy had been performed in all patients pre-operatively to assess the extent of the intra-articular lesions. The American Orthopaedic Foot and Ankle Society hind-foot score was used for clinical evaluation and showed a significant difference in both the total and the functional scores (p < 0.05), but not in those for pain or alignment, in favour of the group with a damaged deltoid ligament (p < 0.05). The only significant difference between the groups on the short-form 36 quality-of-life score was for bodily pain, again in favour of the group with a damaged deltoid ligament. There was no significant difference between the groups in the subjective visual analogue scores or in the modified Kannus radiological score. Arthroscopically, there was a significant difference with an increased risk of loose bodies in the group with an intact deltoid ligament (p < 0.005), although there was no significant increased risk of deep cartilage lesions in the two groups. At a mean follow-up of 13 years after operative treatment of a supination-external rotation type-4 ankle fracture patients with partial or complete rupture of the medial deltoid ligament tended to have a better result than those with a medial malleolar fracture


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims. Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Methods. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft. Results. Similar migration profiles were observed in all directions during the course of healing. At one year, eight patients in the SHS group and 12 patients in the TSP group were available for analysis, finding a clinically non-relevant, and statistically non-significant, difference in total translation of 1 mm (95% confidence interval -4.7 to 2.9) in favour of the TSP group. In line with the migration data, no significant differences in clinical outcomes were found. Conclusion. The TSP did not influence the course of healing or postoperative fracture motion compared to SHS alone. Based on our results, routine use of the TSP in AO/OTA 31-A2 trochanteric fractures cannot be recommended. The TSP has been shown, in biomechanical studies, to increase stability in sliding hip screw constructs in both unstable and intermediate stable trochanteric fractures, but the clinical evidence is limited. This study showed no advantage of the TSP in unstable (AO 31-A2) fractures in elderly patients when fracture movement was evaluated with radiostereometric analysis. Cite this article: Bone Jt Open 2024;5(1):37–45


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 178 - 183
1 Jan 2021
Kubik JF Rollick NC Bear J Diamond O Nguyen JT Kleeblad LJ Wellman DS Helfet DL

Aims. Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Methods. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances. Results. A difference of anterior to posterior syndesmotic distance > 2 mm was observed in 89% of ankles (n = 190) on unilateral CT assessment. Using bilateral CT, we found that 35% (n = 75) of normal ankles would be considered malreduced by current malreduction parameters. In 50 patients (23%), only one parameter was anomalous, 18 patients (8%) had two positive parameters and seven patients (3%) had three. Difference in fibular rotation had the lowest false positive rate of all parameters at 6%, whereas posterior syndesmotic distance difference had the highest at 15%. Conclusion. In this study, 35% of native, uninjured syndesmoses (n = 75) would be classified as malreduced by current diagnostic standards on bilateral CT and 89% had an asymmetric incisura on unilateral CT (n = 190). Current radiological parameters are insufficient to differentiate mild inherent anatomical asymmetry from malreduction of the syndesmosis. Cite this article: Bone Joint J 2021;103-B(1):178–183


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1229 - 1241
14 Sep 2020
Blom RP Hayat B Al-Dirini RMA Sierevelt I Kerkhoffs GMMJ Goslings JC Jaarsma RL Doornberg JN

Aims. The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size. Methods. This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up. Results. Bivariate analyses revealed that fracture morphology (p = 0.039) as well as fragment size (p = 0.007) were significantly associated with the FAOS. However, in multivariate analyses, fracture morphology (p = 0.001) (but not fragment size (p = 0.432)) and the residual intra-articular gap(s) (p = 0.009) were significantly associated. Haraguchi Type-II PMAFs had poorer FAOS scores compared with Types I and III. Multivariate analyses identified the following independent predictors: step-off in Type I; none of the Q3DCT-measurements in Type II, and quality of syndesmotic reduction in small-avulsion Type III PMAFs. Conclusion. PMAFs are three separate entities based on fracture morphology, with different predictors of outcome for each PMAF type. The current debate on whether or not to fix PMAFs needs to be refined to determine which morphological subtype benefits from fixation. In PMAFs, fracture morphology should guide treatment instead of fragment size. Cite this article: Bone Joint J 2020;102-B(9):1229–1241


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1114 - 1119
19 Dec 2024
Wachtel N Giunta RE Hellweg M Hirschmann M Kuhlmann C Moellhoff N Ehrl D

Aims

The free latissimus dorsi muscle (LDM) flap represents a workhorse procedure in the field of trauma and plastic surgery. However, only a small number of studies have examined this large group of patients with regard to the morbidity of flap harvest. The aim of this prospective study was therefore to objectively investigate the morbidity of a free LDM flap.

Methods

A control group (n = 100) without surgery was recruited to assess the differences in strength and range of motion (ROM) in the shoulder joint with regard to handedness of patients. Additionally, in 40 patients with free LDM flap surgery, these parameters were assessed in an identical manner.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 688 - 695
1 Jun 2023
Johnston GHF Mastel M Sims LA Cheng Y

Aims

The aims of this study were to identify means to quantify coronal plane displacement associated with distal radius fractures (DRFs), and to understand their relationship to radial inclination (RI).

Methods

From posteroanterior digital radiographs of healed DRFs in 398 female patients aged 70 years or older, and 32 unfractured control wrists, the relationships of RI, quantifiably, to four linear measurements made perpendicular to reference distal radial shaft (DRS) and ulnar shaft (DUS) axes were analyzed: 1) DRS to radial aspect of ulnar head (DRS-U); 2) DUS to volar-ulnar corner of distal radius (DUS-R); 3) DRS to proximal capitate (DRS-PC); and 4) DRS to DUS (interaxis distance, IAD); and, qualitatively, to the distal ulnar fracture, and its intersection with the DUS axis.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 236 - 242
22 Mar 2024
Guryel E McEwan J Qureshi AA Robertson A Ahluwalia R

Aims

Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest.

Methods

A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims

To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture.

Methods

This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims

The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs.

Methods

The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%).


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 972 - 979
1 Aug 2022
Richardson C Bretherton CP Raza M Zargaran A Eardley WGP Trompeter AJ

Aims

The purpose of this study was to determine the weightbearing practice of operatively managed fragility fractures in the setting of publically funded health services in the UK and Ireland.

Methods

The Fragility Fracture Postoperative Mobilisation (FFPOM) multicentre audit included all patients aged 60 years and older undergoing surgery for a fragility fracture of the lower limb between 1 January 2019 and 30 June 2019, and 1 February 2021 and 14 March 2021. Fractures arising from high-energy transfer trauma, patients with multiple injuries, and those associated with metastatic deposits or infection were excluded. We analyzed this patient cohort to determine adherence to the British Orthopaedic Association Standard, “all surgery in the frail patient should be performed to allow full weight-bearing for activities required for daily living”.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation. Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures. This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation. Cite this article: Bone Joint J 2015;97-B:391–7


Bone & Joint Open
Vol. 3, Issue 2 | Pages 165 - 172
21 Feb 2022
Kuwahara Y Takegami Y Tokutake K Yamada Y Komaki K Ichikawa T Imagama S

Aims

Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes.

Methods

In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 118 - 124
1 Jun 2012
Grawe B Le T Williamson S Archdeacon A Zardiackas L

Objectives. We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone. Methods. Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two constructs: 1) two locking screws using a five-hole locking compression plate (LCP) plate; or 2) three non-locking screws with a seven-hole LCP plate across each side of the fracture gap. The stiffness, maximum displacement, mode of failure and number of cycles to failure were recorded under progressive cyclic torsional and eccentric axial loading. Results. Locking plates in normal bone survived 10% fewer cycles to failure during cyclic axial loading, but there was no significant difference in maximum displacement or failure load. Locking plates in osteoporotic bone showed less displacement (p = 0.02), but no significant difference in number of cycles to failure or failure load during cyclic axial loading (p = 0.46 and p = 0.25, respectively). Locking plates in normal bone had lower stiffness and torque during torsion testing (both p = 0.03), but there was no significant difference in rotation (angular displacement) (p = 0.84). Locking plates in osteoporotic bone showed lower torque and rotation (p = 0.008), but there was no significant difference in stiffness during torsion testing (p = 0.69). Conclusions. The mechanical performance of locking plate constructs, using only two screws, is comparable to three non-locking screw constructs in osteoporotic bone. Normal bone loaded with either an axial or torsional moment showed slightly better performance with the non-locking construct


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 830 - 835
1 Jun 2015
Li SL Lu Y Wang MY

This study compares the outcomes of two methods of fixation of displaced fractures of the radial neck. The 58 patients with a mean age of 38.5 years (18 to 56), were treated in a non randomised study with screws (n = 29) or a plate and screws (n = 29) according to the surgeon’s preference. The patients were reviewed at one year. Radiographs and functional evaluations were carried out up to one year post-operatively, using the Broberg and Morrey functional evaluation score, range of movement, and assessment of complications. The mean functional scores did not differ significantly between groups (90 (55 to 100) vs 84; 50 to 100, p = 0.09), but the mean range of forearm rotation in screw group was significantly better than in the plate group (152°; 110° to 170° vs 134°; 80° to 170°, p = 0.001). Although not statistically significant, the screw group had a lower incidence of heterotopic ossification than the plate group (n = 1) than the plated group (n = 3) and the pathology was graded as less severe. Cite this article: Bone Joint J 2015;97-B:830–5


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1126 - 1131
1 Aug 2015
Nortunen S Flinkkilä T Lantto I Kortekangas T Niinimäki J Ohtonen P Pakarinen H

We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination–external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test. For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47). . In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result. Cite this article: Bone Joint J 2015; 97-B:1126–31


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims

The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols.

Methods

A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.


Bone & Joint Open
Vol. 1, Issue 8 | Pages 481 - 487
11 Aug 2020
Garner MR Warner SJ Heiner JA Kim YT Agel J

Aims

To compare results of institutional preferences with regard to treatment of soft tissues in the setting of open tibial shaft fractures.

Methods

We present a retrospective review of open tibial shaft fractures at two high-volume level 1 trauma centres with differing practices with regard to the acute management of soft tissues. Site 1 attempts acute primary closure, while site 2 prefers delayed closure/coverage. Comparisons include percentage of primary closure, number of surgical procedures until definitive closure, percentage requiring soft tissue coverage, and percentage of 90-day wound complication.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 103 - 114
13 May 2020
James HK Gregory RJH Tennent D Pattison GTR Fisher JD Griffin DR

Aims

The primary aim of the survey was to map the current provision of simulation training within UK and Republic of Ireland (RoI) trauma and orthopaedic (T&O) specialist training programmes to inform future design of a simulation based-curriculum. The secondary aims were to characterize; the types of simulation offered to trainees by stage of training, the sources of funding for simulation, the barriers to providing simulation in training, and to measure current research activity assessing the educational impact of simulation.

Methods

The development of the survey was a collaborative effort between the authors and the British Orthopaedic Association Simulation Group. The survey items were embedded in the Performance and Opportunity Dashboard, which annually audits quality in training across several domains on behalf of the Speciality Advisory Committee (SAC). The survey was sent via email to the 30 training programme directors in March 2019. Data were retrieved and analyzed at the Warwick Clinical Trials Unit, UK.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 516 - 520
1 Apr 2007
Bufquin T Hersan A Hubert L Massin P

We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58). The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed peri-prosthetic calcification in 36 patients (90%), displacement of the tuberosities in 19 (53%) and a scapular notch in ten (25%). Compared with conventional hemiarthroplasty, satisfactory mobility was obtained despite frequent migration of the tuberosities. However, long-term results are required before reverse shoulder arthroplasty can be recommended as a routine procedure in complex fractures of the upper humerus in the elderly


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1218 - 1224
1 Sep 2007
Molloy AP Myerson MS Yoon P

We have treated 14 patients (15 fractures) with nonunion of an intra-articular fracture of the body of the calcaneum. The mean follow-up was six years (2 to 8.5). A total of 14 fractures (93%) had initially been treated operatively with 12 (86%) having non-anatomical reductions. Four feet (27%) had concomitant osteomyelitis. Of the nonunions, 14 (93%) went on to eventual union after an average of two reconstructive procedures. All underwent bone grafting of the nonunion. The eventual outcome was a subtalar arthrodesis in ten (67%) cases, a triple arthrodesis in four (27%) and a nonunion in one (6%). Three patients had a wound dehiscence; all required a local rotation flap. The mean American Orthopaedic Foot and Ankle Society score at latest follow-up was 69, and the mean Visual analogue scale was 3. Of those who were initially employed, 82% (9 of 11) eventually returned to work. We present an algorithm for the treatment of calcaneal nonunion, and conclude that despite a relatively high rate of complication, this complex surgery has a high union rate and a good functional outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 955 - 962
1 Nov 1999
Lindahl J Hirvensalo E Böstman O Santavirta S

We reviewed 110 patients with an unstable fracture of the pelvic ring who had been treated with a trapezoidal external fixator after a mean follow-up of 4.1 years. There were eight open-book (type B1, B3-1) injuries, 62 lateral compression (type B2, B3-2) and 40 rotationally and vertically unstable (type C1-C3) injuries. The rate of complications was high with loss of reduction in 57%, malunion in 58%, nonunion in 5%, infection at the pin site in 24%, loosening of the pins in 2%, injury to the lateral femoral cutaneous nerve in 2%, and pressure sores in 3%. The external fixator failed to give and maintain a proper reduction in six of the eight open-book injuries, in 20 of the 62 lateral compression injuries, and in 38 of the 40 type-C injuries. Poor functional results were usually associated with failure of reduction and an unsatisfactory radiological appearance. In type-C injuries more than 10 mm of residual vertical displacement of the injury to the posterior pelvic ring was significantly related to poor outcome. In 14 patients in this unsatisfactory group poor functional results were also affected by associated nerve injuries. In lateral compression injuries the degree of displacement of fractures of the pubic rami caused by internal rotation of the hemipelvis was an important prognostic factor. External fixation may be useful in the acute phase of resuscitation but it is of limited value in the definitive treatment of an unstable type-C injury and in type-B open-book injuries. It is usually unnecessary in minimally displaced lateral compression injuries


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 42 - 47
1 Jan 2020
Jayakumar P Teunis T Vranceanu AM Williams M Lamb S Ring D Gwilym S

Aims

Patient engagement in adaptive health behaviours and interactions with their healthcare ecosystem can be measured using self-reported instruments, such as the Patient Activation Measure (PAM-13) and the Effective Consumer Scale (ECS-17). Few studies have investigated the influence of patient engagement on limitations (patient-reported outcome measures (PROMs)) and patient-reported experience measures (PREMs). First, we assessed whether patient engagement (PAM-13, ECS-17) within two to four weeks of an upper limb fracture was associated with limitations (the Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), and Patient-Reported Outcome Measurement Information System Upper Extremity Physical Function computer adaptive test (PROMIS UE PF) scores) measured six to nine months after fracture, accounting for demographic, clinical, and psychosocial factors. Secondly, we assessed the association between patient engagement and experience (numerical rating scale for satisfaction with care (NRS-C) and satisfaction with services (NRS-S) six to nine months after fracture.

Methods

A total of 744 adults with an isolated fracture of the proximal humerus, elbow, or distal radius completed PROMs. Due to multicollinearity of patient engagement and psychosocial variables, we generated a single variable combining measures of engagement and psychosocial factors using factor analysis. We then performed multivariable analysis with p < 0.10 on bivariate analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims

In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia.

Patients and Methods

Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1307 - 1312
1 Oct 2019
Jacxsens M Schmid J Zdravkovic V Jost B Spross C

Aims

In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries.

Patients and Methods

Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1253 - 1255
1 Sep 2005
Alam A Willett K Ostlere S

Incomplete intertrochanteric fractures do not extend across to the medial femoral cortex and are stable, without rotational deformity or shortening of the lower limb. The aim of our study was to establish whether they can be successfully managed conservatively. A total of 68 patients over a five-year period presented with a suspected fracture of the femoral neck and underwent an MRI scan for further assessment. From these, we retrospectively reviewed eight patients with normal plain radiographs but with an incomplete, intertrochanteric fracture on MRI scan. Five were managed conservatively and three operatively. The mean length of hospital stay was 16 days for the conservatively-treated group and 15 days for those who underwent surgery; this was not statistically significant (p > 0.5) and all patients were mobilised on discharge. Although five patients were readmitted at a mean of 3.2 years after discharge, none had progressed to a complete fracture. We believe that patients with incomplete intertrochanteric fractures should be considered for conservative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 232 - 238
1 Mar 2004
Matsuzaki K Nakatani N Harada M Tamaki T

In 1980, we developed a specially designed brace for treating supracondylar fractures of the humerus in children, along with an easy and safe technique of reduction by skeletal traction. This method, which takes into consideration only the medial tilting and anterior angulation of the distal fragment, achieves complete reduction, ignoring any lateral, posterior and minor rotational displacements of the fragment. Skeletal traction is applied through a screw inserted into the olecranon and the angulation at the fracture site is reduced regardless of the anatomical position without manipulation. We treated 193 children with displaced supracondylar fractures of the humerus using this method between 1980 and 2001. Only four children (2%) developed cubitus varus. The majority obtained an excellent range of movement at the elbow; one had a 25° limitation of flexion. This technique is an effective and easy method of treating supracondylar fractures of the humerus in children


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 652 - 654
1 Jul 2000
Tornetta P Tiburzi D

Retrograde femoral nailing is gaining in popularity. We report a prospective, randomised comparison of antegrade and retrograde procedures in 68 patients with 69 fractures of the femoral shaft. All nails were inserted after appropriate reaming. There was no difference in operating time, blood loss, technical complications, size of nail or reamer, or transfusion requirements. There were more problems of length and rotation using a retrograde technique on a radiolucent table than with an antegrade approach on a fracture table. All fractures in both groups healed and there was no difference in the time taken to achieve union. Although retrograde nailing is a promising technique the skills required need practice. A longer period of follow-up is necessary to determine whether there are long-term problems in the knee after such surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 748 - 752
1 Sep 1997
Song H Cho S Jeong S Park Y Koo K

Stable fixation after a corrective supracondylar osteotomy in adults is difficult because of the irregularity of the area of bony contact, displacement of the fragments, the predominance of cortical bone, and the need for early mobilisation. We have used the Ilizarov apparatus for fixation in 15 patients who were treated by complex osteotomies with displacement of fragments for cubitus varus or valgus. Most patients with cubitus varus required medial displacement with rotation of the distal fragment. Those with cubitus valgus required lateral shift of the distal fragment to reduce the medial prominence of the elbow that would otherwise result. All osteotomies united within the expected time without loss of correction, despite early mobilisation. Complications related to the fixation were few and had resolved at the long-term follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 4 - 8
1 Jan 1997
Krettek C Miclau T Blauth M Lindsey RW Donow C Tscherne H

Rotational deformity following intramedullary nailing may cause symptoms and require surgical correction by osteotomy. Reamed, locked intramedullary nailing may be performed, but concern about cortical blood supply and potential pulmonary dysfunction from reaming have led many surgeons to limit this and use smaller diameter nails. Slotted nails are commonly used but are less stiff in torsion than the newer unslotted nails, particularly at the lower diameters. We report two cased of recurrent femoral rotational deformity after using statically interlocked slotted intramedullary nails to correct existing femoral rotational deformities. These patients show that small diameter statically interlocked femoral nails with diminished bone-nail contact must be stiff enough in rotation to avoid potential recurrence


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1227 - 1233
1 Sep 2018
Gitajn IL Titus AJ Tosteson AN Sprague S Jeray K Petrisor B Swiontkowski M Bhandari M Slobogean G

Aims

The aims of this study were to quantify health state utility values (HSUVs) after a tibial fracture, investigate the effect of complications, to determine the trajectory in HSUVs that result in these differences and to quantify the quality-adjusted life years (QALYs) experienced by patients.

Patients and Methods

This is an analysis of 2138 tibial fractures enrolled in the Fluid Lavage of Open Wounds (FLOW) and Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) trials. Patients returned for follow-up at two and six weeks and three, six, nine and 12 months. Short-Form Six-Dimension (SF-6D) values were calculated and used to calculate QALYs.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 972 - 976
1 Sep 2000
Wakefield AE McQueen MM

The capacity for physiotherapy to improve the outcome after fracture of the distal radius is unproven. We carried out a randomised controlled trial on 96 patients, comparing conventional physiotherapy with a regime of home exercises. The function of the upper limb was assessed at the time of removal of the plaster cast and at three and six months after injury. Factors which may predict poor outcome in these patients were sought. Grip strength and hand function did not significantly differ between the two groups. Flexion and extension of the wrist were the only movements to improve with physiotherapy at six months (p = 0.001). Predictors of poor functional outcome were malunion and impaired function before the fracture. These patients presented with pain, decreased rotation of the forearm and low functional scores at six weeks. Our study has shown that home exercises are adequate rehabilitation after uncomplicated fracture of the distal radius, and routine referral for a course of physiotherapy should be discouraged. The role of physiotherapy in patients at high risk of a poor outcome requires further investigation


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 413 - 418
1 May 1996
McKee MD Richards RR

We reviewed 23 patients who had had 25 Darrach procedures for traumatic or post-traumatic disorders of the wrist at a mean follow-up of 75.5 months (36 to 121). The mean age at the time of operation was 61.1 years (34 to 82). All patients were reviewed in person. Assessment included a history, a questionnaire on patient satisfaction and a detailed physical examination. Standardised radiographs of both wrists were taken with the patient’s hands in a resting position and during maximal grip. Convergence of the distal ulnar stump towards the distal radius during maximal grip (dynamic radio-ulnar convergence) was seen in 14 wrists including five with actual contact (dynamic radio-ulnar impingement), but this produced symptoms in only two cases. The presence of dynamic radio-ulnar convergence did not correlate with grip strength, pinch strength, range of movement or wrist score, but was associated with increased length of excision of the distal ulna. Nineteen of the 23 patients were satisfied with the procedure. Dynamic radio-ulnar convergence is common after the Darrach procedure, but is rarely symptomatic; resection of the distal ulna remains a reliable procedure in the older patient with pain and loss of movement. Excision of the lower end of the ulna should be restricted to the least required to restore full rotation


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1399 - 1408
1 Oct 2017
Scott CEH MacDonald D Moran M White TO Patton JT Keating JF

Aims

To evaluate the outcomes of cemented total hip arthroplasty (THA) following a fracture of the acetabulum, with evaluation of risk factors and comparison with a patient group with no history of fracture.

Patients and Methods

Between 1992 and 2016, 49 patients (33 male) with mean age of 57 years (25 to 87) underwent cemented THA at a mean of 6.5 years (0.1 to 25) following acetabular fracture. A total of 38 had undergone surgical fixation and 11 had been treated non-operatively; 13 patients died at a mean of 10.2 years after THA (0.6 to 19). Patients were assessed pre-operatively, at one year and at final follow-up (mean 9.1 years, 0.5 to 23) using the Oxford Hip Score (OHS). Implant survivorship was assessed. An age and gender-matched cohort of THAs performed for non-traumatic osteoarthritis (OA) or avascular necrosis (AVN) (n = 98) were used to compare complications and patient-reported outcome measures (PROMs).


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 975 - 978
1 Nov 1997
Bar-On E Sagiv S Porat S

We report the outcome of 19 children aged 5.2 to 13.2 years with 20 fractures of the femoral shaft requiring surgery, who were randomly assigned to have external fixation (EF) or flexible intramedullary nailing (FIN) (10 fractures each). The duration of the operation averaged 56 minutes for the EF group with 1.4 minutes of fluoroscopy, compared with 74 minutes and 2.6 minutes, respectively, for the FIN group. The early postoperative course was similar, but the EF group showed much more callus formation. The time to full weight-bearing, full range of movement and return to school were all shorter in the FIN group. The FIN complications included one transitory foot drop and two cases of bursitis at an insertion site. In the EF group there was one refracture, one rotatory malunion requiring remanipulation and two pin-track infections. At an average follow-up of 14 months two patients in the EF group had mild pain, four had quadriceps wasting, one had leg-length discrepancy of over 1 cm, four had malalignment of over 5°, and one had limited hip rotation. In the FIN group, one patient had mild pain and one had quadriceps wasting; there were no length discrepancies, malalignment or limitation of movement. Parents of the FIN group were more satisfied. We recommend the use of flexible intramedullary nailing for fractures of the femoral shaft which require surgery, and reserve external fixation for open or severely comminuted fractures


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 973 - 983
1 Jul 2018
Schmal H Froberg L S. Larsen M Südkamp NP Pohlemann T Aghayev E Goodwin Burri K

Aims

The best method of treating unstable pelvic fractures that involve the obturator ring is still a matter for debate. This study compared three methods of treatment: nonoperative, isolated posterior fixation and combined anteroposterior stabilization.

Patients and Methods

The study used data from the German Pelvic Trauma Registry and compared patients undergoing conservative management (n = 2394), surgical treatment (n = 1345) and transpubic surgery, including posterior stabilization (n = 730) with isolated posterior osteosynthesis (n = 405) in non-complex Type B and C fractures that only involved the obturator ring anteriorly. Calculated odds ratios were adjusted for potential confounders. Outcome criteria were intraoperative and general short-term complications, the incidence of nerve injuries, and mortality.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims

This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect.

Patients and Methods

A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 964 - 972
1 Jul 2017
Duckworth AD Clement ND McEachan JE White TO Court-Brown CM McQueen MM

Aims

The aim of this prospective randomised controlled trial was to compare non-operative and operative management for acute isolated displaced fractures of the olecranon in patients aged ≥ 75 years.

Patients and Methods

Patients were randomised to either non-operative management or operative management with either tension-band wiring or fixation with a plate. They were reviewed at six weeks, three and six months and one year after the injury. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims

The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications.

Patients and Methods

We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51).


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1665 - 1676
1 Dec 2017
Stinton SB Graham PL Moloney NA Maclachlan LR Edgar DW Pappas E

Aims

To synthesise the literature and perform a meta-analysis detailing the longitudinal recovery in the first two years following a distal radius fracture (DRF) managed with volar plate fixation.

Materials and Methods

Three databases were searched to identify relevant articles. Following eligibility screening and quality assessment, data were extracted and outcomes were assimilated at the post-operative time points of interest. A state-of-the-art longitudinal mixed-effects meta-analysis model was employed to analyse the data.


Bone & Joint Research
Vol. 6, Issue 4 | Pages 216 - 223
1 Apr 2017
Ang BFH Chen JY Yew AKS Chua SK Chou SM Chia SL Koh JSB Howe TS

Objectives

External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate the axial and torsional stiffness of the externalised titanium locking compression plate (ET-LCP), the externalised stainless steel locking compression plate (ESS-LCP) and the unilateral external fixator (UEF).

Methods

A fracture gap model was created to simulate comminuted mid-shaft tibia fractures using synthetic composite bones. Fifteen constructs were stabilised with ET-LCP, ESS-LCP or UEF (five constructs each). The constructs were loaded under both axial and torsional directions to determine construct stiffness.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 508 - 515
1 Apr 2017
Haefeli PC Marecek GS Keel MJB Siebenrock KA Tannast M

Aims

The aims of this study were to determine the cumulative ten-year survivorship of hips treated for acetabular fractures using surgical hip dislocation and to identify factors predictive of an unfavourable outcome.

Patients and Methods

We followed up 60 consecutive patients (61 hips; mean age 36.3 years, standard deviation (sd) 15) who underwent open reduction and internal fixation for a displaced fracture of the acetabulum (24 posterior wall, 18 transverse and posterior wall, ten transverse, and nine others) with a mean follow-up of 12.4 years (sd 3).


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 128 - 133
1 Jan 2017
Socci AR Casemyr NE Leslie MP Baumgaertner MR

Aims

The aim of this paper is to review the evidence relating to the anatomy of the proximal femur, the geometry of the fracture and the characteristics of implants and methods of fixation of intertrochanteric fractures of the hip.

Materials and Methods

Relevant papers were identified from appropriate clinical databases and a narrative review was undertaken.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 1003 - 1008
1 Jul 2016
Fenton P Al-Nammari S Blundell C Davies M

Aims

Although infrequent, a fracture of the cuboid can lead to significant disruption of the integrity of the midfoot and its function. The purpose of this study was to classify the pattern of fractures of the cuboid, relate them to the mechanism of injury and suggest methods of managing them.

Patients and Methods

We performed a retrospective review of patients with radiologically reported cuboid fractures. Fractures were grouped according to commonly occurring patterns of injury. A total of 192 fractures in 188 patients were included. They were classified into five patterns of injury.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1668 - 1673
1 Dec 2016
Konda SR Goch AM Leucht P Christiano A Gyftopoulos S Yoeli G Egol KA

Aims

To evaluate whether an ultra-low-dose CT protocol can diagnose selected limb fractures as well as conventional CT (C-CT).

Patients and Methods

We prospectively studied 40 consecutive patients with a limb fracture in whom a CT scan was indicated. These were scanned using an ultra-low-dose CT Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) protocol. Studies from 16 selected cases were compared with 16 C-CT scans matched for age, gender and type of fracture. Studies were assessed for diagnosis and image quality. Descriptive and reliability statistics were calculated. The total effective radiation dose for each scanned site was compared.