Aims. The aim of this study was to evaluate the clinical and radiological outcomes of
Aim. The aim of this study was to compare the cost-effectiveness of
intramedullary nail fixation and ‘locking’ plate fixation in the
treatment of extra-articular fractures of the distal tibia. Patients and Methods. An economic evaluation was conducted from the perspective of
the United Kingdom National Health Service (NHS) and personal social
services (PSS), based on evidence from the Fixation of Distal Tibia
Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients
were available for analysis. Costs were collected prospectively
over the 12-month follow-up period using trial case report forms
and participant-completed questionnaires. Cost-effectiveness was
reported in terms of incremental cost per quality adjusted life
year (QALY) gained, and net monetary benefit. Sensitivity analyses
were conducted to test the robustness of cost-effectiveness estimates. Results. Mean NHS and PSS costs were significantly lower for patients
treated with an intramedullary nail than for those treated with
a
We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a
We investigated the static and cyclical strength of parallel and angulated
Aims. The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of tibia with a segmental
defect, without compromising the anatomical and functional outcomes
achieved using the classical Ilizarov technique. We also wished
to study the acceptability of this technique using patient-based
objective criteria. Patients and Methods. Between January 2012 and January 2015, 14 consecutive patients
were treated for an infected nonunion of the tibia with a gap and
were included in the study. During stage one, a radical debridement
of bone and soft tissue was undertaken with the introduction of
an antibiotic-loaded cement spacer. At the second stage, the tibia
was stabilized using a long lateral
Filling the empty holes in peri-articular locking
plates may improve the fatigue strength of the fixation. The purpose of
this in vitro study was to investigate the effect
of plugging the unused holes on the fatigue life of peri-articular distal
femoral plates used to fix a comminuted supracondylar fracture model. A
Aims. To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years. Methods. A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar
Aims. Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK. Methods. A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages. Results. A total of 859 patients from 18 different NHS trusts (15 trauma units and three major trauma centres) were included. The mean age was 57 years (18 to 99). Overall, 56% of patients (n = 481) were male. The most common mechanisms of injury were simple fall (57%; n = 487) and high-energy fall (29%; n = 248); 87% (n = 748) were treated conservatively and 54% (n = 463) were Neer type I fractures. Overall, 32% of fractures (n = 275) were type II (22% type IIa (n = 192); 10% type IIb (n = 83)). With regards to operative management, 89% of patients (n = 748) who underwent an operation were under the age of 60. The main fixation methods were: hook plate (n = 47);
A consecutive series of 320 patients with an
intracapsular fracture of the hip treated with a dynamic locking
plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients
were followed for a minimum of two years. During the follow-up period
109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed
nonunion or re-displacement and five (4.5%) developed avascular
necrosis of the femoral head. Revision to an arthroplasty was required
for five patients (4.5%). A further six patients (5.4%) had elective
removal of the plate and screws. There were 208 displaced fractures, of which 32 (15.4%) developed
nonunion or re-displacement and 23 (11.1%) developed avascular necrosis.
A further four patients (1.9%) developed a secondary fracture around
the TFN. Revision to a hip replacement was required for 43 patients
(20.7%) patients and a further seven (3.3%) had elective removal
of the plate and screws. It is suggested that the stronger distal fixation combined with
rotational stability may lead to a reduced incidence of complications
related to the healing of the fracture when compared with other
contemporary fixation devices but this needs to be confirmed in
further studies. Cite this article:
Fractures of the distal femur can be challenging to manage and
are on the increase in the elderly osteoporotic population. Management
with casting or bracing can unacceptably limit a patient’s ability
to bear weight, but historically, operative fixation has been associated
with a high rate of re-operation. In this study, we describe the outcomes
of fixation using modern implants within a strategy of early return
to function. All patients treated at our centre with lateral distal femoral
locking plates (LDFLP) between 2009 and 2014 were identified. Fracture
classification and operative information including weight-bearing
status, rates of union, re-operation, failure of implants and mortality
rate, were recorded.Aims
Patients and Methods
Objectives. External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised
Aims. To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus
Aims. Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. Methods. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral
We investigated a new intramedullary locking
nail that allows the distal interlocking screws to be locked to
the nail. We compared fixation using this new implant with fixation
using either a conventional nail or a
Aims. Fractures of the distal femur are an important cause of morbidity.
Their optimal management remains controversial. Contemporary implants
include angular-stable anatomical
Unstable bicondylar tibial plateau fractures
are rare and there is little guidance in the literature as to the
best form of treatment. We examined the short- to medium-term outcome
of this injury in a consecutive series of patients presenting to
two trauma centres. Between December 2005 and May 2010, a total
of 55 fractures in 54 patients were treated by fixation, 34 with
peri-articular
We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous
This study compares the cost-effectiveness of
treating dorsally displaced distal radial fractures with a volar
locking plate and percutaneous fixation. It was performed from the
perspective of the National Health Service (NHS) using data from
a single-centre randomised controlled trial. In total 130 patients
(18 to 73 years of age) with a dorsally displaced distal radial
fracture were randomised to treatment with either a volar locking
plate (n = 66) or percutaneous fixation (n = 64). The methodology
was according to National Institute for Health and Care Excellence guidance
for technology appraisals. . There were no significant differences in quality of life scores
between groups at any time point in the study. Both groups returned
to baseline one year post-operatively. . NHS costs for the plate group were significantly higher (p <
0.001, 95% confidence interval 497 to 930). For an additional £713,
fixation with a volar
Objectives. The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator. Materials and Methods. An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal
This multicentre prospective clinical trial aimed
to determine whether early administration of alendronate (ALN) delays
fracture healing after surgical treatment of fractures of the distal
radius. The study population comprised 80 patients (four men and
76 women) with a mean age of 70 years (52 to 86) with acute fragility
fractures of the distal radius requiring open reduction and internal
fixation with a volar
A total of 118 consecutive patients with a fracture of the distal radius were treated with a volar
Objectives. We aimed to further evaluate the biomechanical characteristics
of two locking screws versus three standard bicortical
screws in synthetic models of normal and osteoporotic bone. Methods. Synthetic tubular bone models representing normal bone density
and osteoporotic bone density were used. Artificial fracture gaps
of 1 cm were created in each specimen before fixation with one of
two constructs: 1) two locking screws using a five-hole locking
compression plate (LCP) plate; or 2) three non-locking screws with
a seven-hole LCP plate across each side of the fracture gap. The
stiffness, maximum displacement, mode of failure and number of cycles
to failure were recorded under progressive cyclic torsional and
eccentric axial loading. Results. Locking plates in normal bone survived 10% fewer cycles to failure
during cyclic axial loading, but there was no significant difference
in maximum displacement or failure load. Locking plates in osteoporotic
bone showed less displacement (p = 0.02), but no significant difference
in number of cycles to failure or failure load during cyclic axial loading
(p = 0.46 and p = 0.25, respectively). Locking plates in normal
bone had lower stiffness and torque during torsion testing (both
p = 0.03), but there was no significant difference in rotation (angular
displacement) (p = 0.84). Locking plates in osteoporotic bone showed
lower torque and rotation (p = 0.008), but there was no significant difference
in stiffness during torsion testing (p = 0.69). Conclusions. The mechanical performance of
Percutaneous stabilisation of tibial fractures by
The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest. A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).Aims
Methods
Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.Aims
Methods
The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients. In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.Aims
Methods
The purpose was to compare operative treatment with a volar plate and nonoperative treatment of displaced distal radius fractures in patients aged 65 years and over in a cost-effectiveness analysis. A cost-utility analysis was performed alongside a randomized controlled trial. A total of 50 patients were randomized to each group. We prospectively collected data on resource use during the first year post-fracture, and estimated costs of initial treatment, further operations, physiotherapy, home nursing, and production loss. Health-related quality of life was based on the Euro-QoL five-dimension, five-level (EQ-5D-5L) utility index, and quality-adjusted life-years (QALYs) were calculated.Aims
Methods
Proximal humeral fractures (PHFs) are common. There is increasing evidence that most of these fractures should be treated conservatively. However, recent studies have shown an increase in use of operative treatment. The aim of this study was to identify the trends in the incidence and methods of treatment of PHFs in Finland. The study included all Finnish inhabitants aged ≥ 16 years between 1997 and 2019. All records, including diagnostic codes for PHFs and all surgical procedure codes for these fractures, were identified from two national registers. Data exclusion criteria were implemented in order to identify only acute PHFs, and the operations performed to treat them.Aims
Methods
The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.Aims
Methods
Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes. In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes.Aims
Methods
Objectives. To investigate the differences of open reduction and internal
fixation (ORIF) of complex AO Type C distal radius fractures between
two different models of a single implant type. Methods. A total of 136 patients who received either a 2.4 mm (n = 61)
or 3.5 mm (n = 75) distal radius
Fractures of the distal radius are common, and form a considerable proportion of the trauma workload. We conducted a study to examine the patterns of injury and treatment for adult patients presenting with distal radius fractures to a major trauma centre serving an urban population. We undertook a retrospective cohort study to identify all patients treated at our major trauma centre for a distal radius fracture between 1 June 2018 and 1 May 2021. We reviewed the medical records and imaging for each patient to examine patterns of injury and treatment. We undertook a binomial logistic regression to produce a predictive model for operative fixation or inpatient admission.Aims
Methods
Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome. Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.Aims
Methods
The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing. A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.Aims
Methods
To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes. A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.Aims
Methods
Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.Aims
Methods
Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP. This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity.Aims
Methods
This study reviews the past 30 years of research from the Canadian Orthopedic Trauma Society (COTS), to identify predictive factors that delay or accelerate the course of randomized controlled trials in orthopaedic trauma. We conducted a methodological review of all papers published through the Canadian Orthopaedic Trauma Society or its affiliates. Data abstracted included: year of publication; journal of publication; study type; number of study sites; sample size; and achievement of sample size goals. Information about the study timelines was also collected, including: the date of study proposal to COTS; date recruitment began; date recruitment ended; and date of publication.Aims
Methods
The aim of this study was to examine trends in the management of fractures of the distal radius in Ireland over a ten-year period, and to determine if there were any changes in response to the English Distal Radius Acute Fracture Fixation Trial (DRAFFT). Data was grouped into annual intervals from 2008 to 2017. All adult inpatient episodes that involved emergency surgery for fractures of the distal radius were includedAims
Patients and Methods
To compare the functionality of adults with displaced mid-shaft clavicular fractures treated either operatively or nonoperatively and to compare the relative risk of nonunion and reoperation between the two groups. Based on specific eligibility criteria, 120 adults (median age 37.5 years (interquartile range (18 to 61)) and 84% males (n = 101)) diagnosed with an acute displaced mid-shaft fracture were recruited, and randomized to either the operative (n = 60) or nonoperative (n = 60) treatment group. This randomized controlled, partially blinded trial followed patients for 12 months following initial treatment. Functionality was assessed by the Constant score (CS) (assessor blinded to treatment) and Disability of the Arm, Shoulder and Hand (DASH) score. Clinical and radiological evaluation, and review of patient files for complications and reoperations, were added as secondary outcomes.Aims
Methods
No randomized comparative study has compared the extensile lateral approach (ELA) and sinus tarsi approach (STA) for Sanders type 2 calcaneal fractures. This randomized comparative study was conducted to confirm whether the STA was prone to fewer wound complications than the ELA. Between August 2013 and August 2018, 64 patients with Sanders type 2 calcaneus fractures were randomly assigned to receive surgical treatment by the ELA (32 patients) and STA (32 patients). The primary outcome was development of wound complications. The secondary outcomes were postoperative complications, pain scored of a visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, 36-item Short Form health survey, operative duration, subtalar joint range of motion (ROM), Böhler’s angle and calcaneal width, and posterior facet reduction.Aims
Methods
The augmentation of fixation with bone cement
is increasingly being used in the treatment of severe osteoporotic fractures.
We investigated the influence of bone quality on the mechanics of
augmentation of plate fixation in a distal femoral fracture model
(AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral
models were randomly assigned to either an augmented or a non-augmented
group. Fixation was performed using a
The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot.Aims
Methods
The aim of this study was to assess the feasibility of conducting a full-scale, appropriately powered, randomized controlled trial (RCT) comparing internal fracture fixation and distal femoral replacement (DFR) for distal femoral fractures in older patients. Seven centres recruited patients into the study. Patients were eligible if they were greater than 65 years of age with a distal femoral fracture, and if the surgeon felt that they were suitable for either form of treatment. Outcome measures included the patients’ willingness to participate, clinicians’ willingness to recruit, rates of loss to follow-up, the ability to capture data, estimates of standard deviation to inform the sample size calculation, and the main determinants of cost. The primary clinical outcome measure was the EuroQol five-dimensional index (EQ-5D) at six months following injury.Aims
Patients and Methods
The primary aim of this study was to determine if delayed clavicular fixation results in a greater risk of operative complications and revision surgery. A retrospective case series was undertaken of all displaced clavicular fractures that underwent plate fixation over a ten-year period (2007 to 2017). Patient demographics, time to surgery, complications, and mode of failure were collected. Logistic regression was used to identify independent risk factors contributing towards operative complications. Receiver operating characteristic (ROC) curve analysis was used to determine if a potential ‘safe window’ exists from injury to delayed surgery. Propensity score matching was used to construct a case control study for comparison of risk.Aims
Patients and Methods
The primary aim of this study was to establish the cost-effectiveness of the early fixation of displaced midshaft clavicle fractures. A cost analysis was conducted within a randomized controlled trial comparing conservative management (n = 92) Aims
Patients and Methods
This study reviews the use of a titanium mesh cage (TMC) as an
adjunct to intramedullary nail or plate reconstruction of an extra-articular
segmental long bone defect. A total of 17 patients (aged 17 to 61 years) treated for a segmental
long bone defect by nail or plate fixation and an adjunctive TMC
were included. The bone defects treated were in the tibia (nine),
femur (six), radius (one), and humerus (one). The mean length of
the segmental bone defect was 8.4 cm (2.2 to 13); the mean length
of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and
radiological records of the patients were analyzed retrospectively.Aims
Patients and Methods
In the time since Letournel popularised the surgical
treatment of acetabular fractures, more than 25 years ago, there
have been many changes within the field, related to patients, surgical
technique, implants and post-operative care. However, the long-term
outcomes appear largely unchanged. Does this represent stasis or
have the advances been mitigated by other negative factors? In this
article we have attempted to document the recent changes within
the surgery of patients with a fracture involving the acetabulum,
outline contemporary management, and identify the major problem
areas where further research is most needed. Cite this article:
The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery. A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.Objectives
Methods