Advertisement for orthosearch.org.uk
Results 1 - 50 of 101
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 867 - 871
1 Jul 2019
Wilcox M Brown H Johnson K Sinisi M Quick TJ

Aims. Improvements in the evaluation of outcomes following peripheral nerve injury are needed. Recent studies have identified muscle fatigue as an inevitable consequence of muscle reinnervation. This study aimed to quantify and characterize muscle fatigue within a standardized surgical model of muscle reinnervation. Patients and Methods. This retrospective cohort study included 12 patients who underwent Oberlin nerve transfer in an attempt to restore flexion of the elbow following brachial plexus injury. There were ten men and two women with a mean age of 45.5 years (27 to 69). The mean follow-up was 58 months (28 to 100). Repeated and sustained isometric contractions of the elbow flexors were used to assess fatigability of reinnervated muscle. The strength of elbow flexion was measured using a static dynamometer (KgF) and surface electromyography (sEMG). Recordings were used to quantify and characterize fatigability of the reinnervated elbow flexor muscles compared with the uninjured contralateral side. Results. The mean peak force of elbow flexion was 7.88 KgF (. sd. 3.80) compared with 20.65 KgF (. sd . 6.88) on the contralateral side (p < 0.001). Reinnervated elbow flexor muscles (biceps brachialis) showed sEMG evidence of fatigue earlier than normal controls with sustained (60-second) isometric contraction. Reinnervated elbow flexor muscles also showed a trend towards a faster twitch muscle fibre type. Conclusion. The assessment of motor outcomes must involve more than peak force alone. Reinnervated muscle shows a shift towards fast twitch fibres following reinnervation with an earlier onset of fatigue. Our findings suggest that fatigue is a clinically relevant characteristic of reinnervated muscle. Adoption of these metrics into clinical practice and the assessment of outcome could allow a more meaningful comparison to be made between differing forms of treatment and encourage advances in the management of motor recovery following nerve transfer. Cite this article: Bone Joint J 2019;101-B:867–871


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1165 - 1175
1 Oct 2024
Frost Teilmann J Petersen ET Thillemann TM Hemmingsen CK Olsen Kipp J Falstie-Jensen T Stilling M

Aims. The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Methods. Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom. Results. The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly. Conclusion. The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA. Cite this article: Bone Joint J 2024;106-B(10):1165–1175


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1301 - 1305
1 Nov 2024
Prajapati A Thakur RPS Gulia A Puri A

Aims. Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection. Methods. Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score. Results. All patients were available for follow-up at a mean of 33 months (25 to 43) and were disease-free. The mean flexion arc was 0° to 105°. Three patients had complications. One had neuropraxia of the ulnar nerve. The symptoms resolved after three months. In one patient, the screw used for fixation of the triceps tendon became exposed and was removed, six months postoperatively. One patient with wound dehiscence required a local flap for soft-tissue cover, four months postoperatively. At a mean follow-up of 33 months (25 to 43), the mean flexion arc was 0° to 105°. All patients had full supination (85°) but none had any pronation. The mean MSTS score was 23.5 (23 to 24) and mean QuickDASH-9 score was 26.13 (16.5 to 35.75). Three patients had varus-valgus instability on examination, although only one had a sense of instability while working. Conclusion. Radial neck to humeral trochlea transposition offers a satisfactory and cost-effective biological reconstructive option after osteoarticular resection of the proximal ulna, in the short term. It provides good elbow function and, being a biological reconstruction option using native bone, is likely to provide long-term stability and durability. Cite this article: Bone Joint J 2024;106-B(11):1301–1305


Bone & Joint Open
Vol. 5, Issue 10 | Pages 851 - 857
10 Oct 2024
Mouchantaf M Parisi M Secci G Biegun M Chelli M Schippers P Boileau P

Aims. Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM. Methods. With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135° inclined polyethylene liner. Results. The configuration with lateralization and correction of the RSA angle (C+L+) led to better ROM in flexion, extension, adduction, and external rotation (p ≤ 0.001). Only internal rotation was not significantly different between groups (p = 0.388). The configuration where correction of the inclination was done by medialization (C+M+) led to the worst ROM in adduction, extension, abduction, flexion, and external rotation of the shoulder. Conclusion. Our software study shows that, when using a 135° inlay reversed humeral implant, correcting glenoid inclination (RSA angle 0°) and lateralizing the glenoid component by using an angled bony or metallic augment of 8 to 10 mm provides optimal impingement-free ROM. Cite this article: Bone Jt Open 2024;5(10):851–857


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1517 - 1520
1 Nov 2016
Quick TJ Singh AK Fox M Sinisi M MacQuillan A

Aims. Improvements in the evaluation of outcome after nerve transfers are required. The assessment of force using the Medical Research Council (MRC) grades (0 to 5) is not suitable for this purpose. A ceiling effect is encountered within MRC grade 4/5 rendering this tool insensitive. Our aim was to show how the strength of flexion of the elbow could be assessed in patients who have undergone a re-innervation procedure using a continuous measurement scale. Methods. A total of 26 patients, 23 men and three women, with a mean age of 37.3 years (16 to 66), at the time of presentation, attended for review from a cohort of 52 patients who had undergone surgery to restore flexion of the elbow after a brachial plexus injury and were included in this retrospective study. The mean follow-up after nerve transfer was 56 months (28 to 101, standard deviation (. sd. ) 20.79). The strength of flexion of the elbow was measured in a standard outpatient environment with a static dynamometer. Results. In total, 21 patients (81%) gained MRC grade 4 strength of flexion of the elbow. The mean force of flexion was 7.2 kgf (3 to 15.5, . sd. 3.3). Conclusion. This study establishes that the dynamometer may be used for assessing the strength of flexion of the elbow in the outpatient department after nerve reconstructive surgery. Cite this article: Bone Joint J 2016;98-B:1517–20


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims. The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment. Methods. Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated. Results. Patients treated with ORIF showed significantly better postoperative range of motion for flexion and extension (121.1° (SD 16.4°) vs 108.1° (SD 25.8°); p = 0.018). Postoperative functional scores also showed significantly better results in the ORIF group (MEPS 90.1 (SD 13.6) vs 78 (SD 20.5); p = 0.004). There was no significant difference between the groups in terms of the complication rate (RHA 23.8% (n = 10) vs ORIF 26.2% (n = 11)). Implant-related complications occurred in six cases (14.3%) in the RHA group and in five cases (11.9%) in the ORIF group. Conclusion. Irrespective of the patient’s age, sex, type of injury, or number of fracture fragments, ORIF of the radial head should be attempted initially, if a stable reconstruction can be achieved, as it seems to provide a superior postoperative outcome for the patient compared to primary RHA. If reconstruction is not feasible, RHA is still a viable alternative. In the surgical treatment of complex radial head fractures, reconstruction shows superior postoperative outcomes compared to RHA. Good postoperative results can be achieved even after failed reconstruction and conversion to secondary RHA. Therefore, we encourage surgeons to favour reconstruction of complex radial head fractures, regardless of injury type or number of fragments, as long as a stable fixation can be achieved. Cite this article: Bone Joint J 2024;106-B(10):1158–1164


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1284 - 1292
1 Nov 2024
Moroder P Poltaretskyi S Raiss P Denard PJ Werner BC Erickson BJ Griffin JW Metcalfe N Siegert P

Aims

The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different.

Methods

A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 826 - 831
28 Oct 2022
Jukes C Dirckx M Bellringer S Chaundy W Phadnis J

Aims. The conventionally described mechanism of distal biceps tendon rupture (DBTR) is of a ‘considerable extension force suddenly applied to a resisting, actively flexed forearm’. This has been commonly paraphrased as an ‘eccentric contracture to a flexed elbow’. Both definitions have been frequently used in the literature with little objective analysis or citation. The aim of the present study was to use video footage of real time distal biceps ruptures to revisit and objectively define the mechanism of injury. Methods. An online search identified 61 videos reporting a DBTR. Videos were independently reviewed by three surgeons to assess forearm rotation, elbow flexion, shoulder position, and type of muscle contraction being exerted at the time of rupture. Prospective data on mechanism of injury and arm position was also collected concurrently for 22 consecutive patients diagnosed with an acute DBTR in order to corroborate the video analysis. Results. Four videos were excluded, leaving 57 for final analysis. Mechanisms of injury included deadlift, bicep curls, calisthenics, arm wrestling, heavy lifting, and boxing. In all, 98% of ruptures occurred with the arm in supination and 89% occurred at 0° to 10° of elbow flexion. Regarding muscle activity, 88% occurred during isometric contraction, 7% during eccentric contraction, and 5% during concentric contraction. Interobserver correlation scores were calculated as 0.66 to 0.89 using the free-marginal Fleiss Kappa tool. The prospectively collected patient data was consistent with the video analysis, with 82% of injuries occurring in supination and 95% in relative elbow extension. Conclusion. Contrary to the classically described injury mechanism, in this study the usual arm position during DBTR was forearm supination and elbow extension, and the muscle contraction was typically isometric. This was demonstrated for both video analysis and ‘real’ patients across a range of activities leading to rupture. Cite this article: Bone Jt Open 2022;3(10):826–831


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1333 - 1338
2 Aug 2021
Kankanalu P Borton ZM Morgan ML Cresswell T Espag MP Tambe AA Clark DI

Aims. Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. Methods. All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up. Results. The implant was revised in ten shoulders (5.2%) with a median time to revision of 21.2 months (interquartile range (IQR) 9.9 to 41.8). The Kaplan-Meier survivorship estimate at seven years was 95.9% (95% confidence interval (CI) 91.7 to 98; 35 RTSAs at risk) for aseptic mechanical failure of the glenoid and 94.8% (95% CI 77.5 to 96.3; 35 RTSAs at risk) for all-cause revision. Minimum five-year clinical and radiological outcomes were available for 103 and 98 RTSAs respectively with a median follow-up time of six years (IQR 5.2 to 7.0). Median postoperative Oxford Shoulder Score was 38 (IQR 31 to 45); median Constant and Murley score was 60 (IQR 47.5 to 70); median forward flexion 115° (IQR 100° to 125°); median abduction 95° (IQR 80° to 120°); and external rotation 25° (IQR 15° to 40°) Scapular notching was seen in 62 RTSAs (63.2%). Conclusion. We present the largest and longest-term series of TM-backed glenoid implants demonstrating 94.8% all-cause survivorship at seven years. Specifically pertaining to glenoid loosening, survival of the implant increased to 95.9%. In addition, we report satisfactory minimum five-year clinical and radiological outcomes. Cite this article: Bone Joint J 2021;103-B(8):1333–1338


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims. Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). Methods. Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection. Results. The accuracy of injection in the US and blind groups was 100% (45/45) and 71.1% (32/45), respectively; this difference was significant (p < 0.001). Both groups had significant improvements in VAS pain score, ASES score, SSV, forward flexion, abduction, external rotation, and internal rotation throughout follow-up until 12 weeks after injection (all p < 0.001). There were no significant differences between the VAS pain scores, the ASES score, the SSV and all ROMs between the two groups at the time points assessed (all p > 0.05). No injection-related adverse effects were noted in either group. Conclusion. We found no significant differences in pain and functional outcomes between the two groups, although an US-guided injection was associated with greater accuracy. Considering that it is both costly and time-consuming, an US-guided intra-articular injection of corticosteroid seems not always to be necessary in the treatment of FS as it gives similar outcomes as a blind injection. Cite this article: Bone Joint J 2021;103-B(2):353–359


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims. To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes. Methods. Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible. Results. At follow-up the mean MEPS was 87.1 (20 to 100); mean OES, 36.9 (6 to 48); and mean DASH score, 18.6 (0 to 90). Mean movement was 118° (30° to 150°) for extension to flexion and 162° (90° to 180°) for pronation to supination. The overall reoperation rate was 24%, with nine ORIF, ten RHA, and two patients without treatment to the radial head needing surgical revision. When treated with RHA, Mason type III fractures exhibited significantly inferior outcomes. Suboptimal results were also identified in patients with degenerative or heterotopic changes on their latest radiograph. In contrast, more favourable outcomes were detected in patients with successful radial head reconstruction after Mason type III fractures. Conclusion. Using a standardized protocol, sufficient elbow stability and good outcomes can be achieved in most TTIs. Although some bias in treatment allocation, with more severe injuries assigned to RHA, cannot be completely omitted, treatment of radial head fractures may have an independent effect on outcome, as patients subjected to RHA showed significantly inferior results compared to those subjected to reconstruction, in terms of elbow function, incidence of arthrosis, and postoperative complications. As RHA showed no apparent advantage in Mason type III injuries between the two treatment groups, we recommend reconstruction, providing stable fixation can be achieved. Cite this article: Bone Joint J 2020;102-B(12):1620–1628


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1284 - 1291
1 Jul 2021
Carter TH Karunaratne BJ Oliver WM Murray IR White TO Reid JT Duckworth AD

Aims. Acute distal biceps tendon repair reduces fatigue-related pain and minimizes loss of supination of the forearm and strength of flexion of the elbow. We report the short- and long-term outcome following repair using fixation with a cortical button techqniue. Methods. Between October 2010 and July 2018, 102 patients with a mean age of 43 years (19 to 67), including 101 males, underwent distal biceps tendon repair less than six weeks after the injury, using cortical button fixation. The primary short-term outcome measure was the rate of complications. The primary long-term outcome measure was the abbreviated Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. Secondary outcomes included the Oxford Elbow Score (OES), EuroQol five-dimension three-level score (EQ-5D-3L), satisfaction, and return to function. Results. Eight patients (7.8%) had a major complication and 34 (33.3%) had a minor complication. Major complications included re-rupture (n = 3; 2.9%), unrecovered nerve injury (n = 4; 3.9%), and surgery for heterotopic ossification (n = 1; 1.0%). Three patients (2.9%) overall required further surgery for a complication. Minor complications included neurapraxia (n = 27; 26.5%) and superficial infection (n = 7; 6.9%). A total of 33 nerve injuries occurred in 31 patients (30.4%). At a mean follow-up of five years (1 to 9.8) outcomes were available for 86 patients (84.3%). The median QuickDASH, OES, EQ-5D-3L, and satisfaction scores were 1.2 (IQR 0 to 5.1), 48 (IQR 46 to 48), 0.80 (IQR 0.72 to 1.0), and 100/100 (IQR 90 to 100), respectively. Most patients were able to return to work (81/83, 97.6%) and sport (51/62,82.3%). Unrecovered nerve injury was associated with an inferior outcome according to the QuickDASH (p = 0.005), OES (p = 0.004), EQ-5D-3L (p = 0.010), and satisfaction (p = 0.024). Multiple linear regression analysis identified an unrecovered nerve injury to be strongly associated with an inferior outcome according to the QuickDASH score (p < 0.001), along with infection (p < 0.001), although re-rupture (p = 0.440) and further surgery (p = 0.652) were not. Conclusion. Acute distal biceps tendon repair using cortical button fixation was found to result in excellent patient-reported outcomes and health-related quality of life. Although rare, unrecovered nerve injury adversely affects outcome. Cite this article: Bone Joint J 2021;103-B(7):1284–1291


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims

Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty.

Methods

This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims

In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.

Methods

A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims

The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance.

Methods

A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims

Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients.

Methods

This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10).


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 964 - 969
1 Sep 2024
Wang YC Song JJ Li TT Yang D Lv ZB Wang ZY Zhang ZM Luo Y

Aims

To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population.

Methods

Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC).


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims

We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients.

Methods

A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 376 - 382
10 Jul 2020
Gill JR Vermuyten L Schenk SA Ong JCY Schenk W

Aims. The aim of this study is to report the results of a case series of olecranon fractures and olecranon osteotomies treated with two bicortical screws. Methods. Data was collected retrospectively for all olecranon fractures and osteotomies fixed with two bicortical screws between January 2008 and December 2019 at our institution. The following outcome measures were assessed; re-operation, complications, radiological loss of reduction, and elbow range of flexion-extension. Results. Bicortical screw fixation was used to treat 17 olecranon fractures and ten osteotomies. The mean age of patients being treated for olecranon fracture and osteotomy were 48.6 years and 52.7 years respectively. Overall, 18% of olecranon fractures were classified as Mayo type I, 71% type II, and 12% type III. No cases of fracture or osteotomy required operative re-intervention. There were two cases of loss of fracture reduction which occurred in female patients ≥ 75 years of age with osteoporotic bone. In both cases, active extension and a functional range of movement was maintained and so the loss of reduction was managed non-operatively. For the fracture fixation cohort, at final follow-up mean elbow extension and flexion were -5. °. ± 5. °. and 136. °. ± 7. °. , with a mean arc of motion of 131. °. ± 11. °. . Conclusion. This series has shown that patients regain near full range of elbow flexion-extension and complication rates are low following bicortical screw fixation of olecranon fractures and osteotomy. Cite this article: Bone Joint Open 2020;1-7:376–382


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1293 - 1300
1 Nov 2024
O’Malley O Craven J Davies A Sabharwal S Reilly P

Aims

Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA.

Methods

MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1041 - 1048
19 Nov 2024
Delgado C Martínez-Rodríguez JM Candura D Valencia M Martínez-Catalán N Calvo E

Aims

The Bankart and Latarjet procedures are two of the most common surgical techniques to treat anterior shoulder instability with satisfactory clinical and functional outcomes. However, the outcomes in the adolescent population remain unclear, and there is no information regarding the arthroscopic Latarjet in this population. The purpose of this study was to evaluate the outcomes of the arthroscopic Bankart and arthroscopic Latarjet procedures in the management of anterior shoulder instability in adolescents.

Methods

We present a retrospective, matched-pair study of teenagers with anterior glenohumeral instability treated with an arthroscopic Bankart repair (ABR) or an arthroscopic Latarjet (AL) procedure with a minimum two-year follow-up. Preoperative demographic and clinical features, factors associated with dislocation, and complications were collected. Recurrence, defined as dislocation or subluxation, was established as the primary outcome. Clinical and functional outcomes were analyzed using objective (Rowe), and subjective (Western Ontario Shoulder Instability Index (WOSI) and Single Assessment Numeric Evaluation (SANE)) scores. Additionally, the rate of return to sport was assessed.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 815 - 825
20 Oct 2022
Athanatos L Kulkarni K Tunnicliffe H Samaras M Singh HP Armstrong AL

Aims

There remains a lack of consensus regarding the management of chronic anterior sternoclavicular joint (SCJ) instability. This study aimed to assess whether a standardized treatment algorithm (incorporating physiotherapy and surgery and based on the presence of trauma) could successfully guide management and reduce the number needing surgery.

Methods

Patients with chronic anterior SCJ instability managed between April 2007 and April 2019 with a standardized treatment algorithm were divided into non-traumatic (offered physiotherapy) and traumatic (offered surgery) groups and evaluated at discharge. Subsequently, midterm outcomes were assessed via a postal questionnaire with a subjective SCJ stability score, Oxford Shoulder Instability Score (OSIS, adapted for the SCJ), and pain visual analogue scale (VAS), with analysis on an intention-to-treat basis.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1273 - 1283
1 Nov 2024
Mahmud H Wang D Topan-Rat A Bull AMJ Heinrichs CH Reilly P Emery R Amis AA Hansen UN

Aims

The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids.

Methods

Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims

The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow.

Methods

We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1512 - 1519
1 Dec 2019
Klug A Konrad F Gramlich Y Hoffmann R Schmidt-Horlohé K

Aims. The aim of this study was to evaluate the outcome of Monteggia-like lesions at midterm follow-up and to determine whether the surgical treatment of the radial head influences the clinical and radiological results. Patients and Methods. A total of 78 patients with a Monteggia-like lesion, including 44 women and 34 men with a mean age of 54.7 years (19 to 80), were available for assessment after a mean 4.6 years (2 to 9.2). The outcome was assessed using the Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), Mayo Modified Wrist Score (MMWS), and The Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiographs were analyzed for all patients. A total of 12 Mason type I, 16 type II, and 36 type III fractures were included. Surgical treatment consisted of screw fixation for all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) or excision was performed if reconstruction was not possible. Results. The mean MEPS was 88.9 (40 to 100), mean OES was 40.1 (25 to 48), mean MMWS was 88.1 (50 to 100), mean DASH score was 14.7 (0 to 60.2), and mean movement was 114° (. sd. 27) in extension/flexion and 155° (. sd. 37) in pronation/supination. Mason III fractures, particularly those with an associated coronoid fracture treated with RHA, had a significantly poorer outcome. Suboptimal results were also identified in patients who had degenerative changes or heterotopic ossification on their latest radiograph. In contrast, all patients with successful radial head reconstruction or excision had a good outcome. Conclusion. Good outcomes can be achieved in Monteggia-like lesions with Mason II and III fractures, when reconstruction is possible. Otherwise, RHA is a reliable option with satisfactory outcomes, especially in patients with ligamenteous instability. Whether the radial head should be excised remains debatable, although good results were achieved in patients with ligamentous stability and in those with complications after RHA. Cite this article: Bone Joint J 2019;101-B:1512–1519


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Lädermann A Tay E Collin P Piotton S Chiu C Michelet A Charbonnier C

Objectives. To date, no study has considered the impact of acromial morphology on shoulder range of movement (ROM). The purpose of our study was to evaluate the effects of lateralization of the centre of rotation (COR) and neck-shaft angle (NSA) on shoulder ROM after reverse shoulder arthroplasty (RSA) in patients with different scapular morphologies. Methods. 3D computer models were constructed from CT scans of 12 patients with a critical shoulder angle (CSA) of 25°, 30°, 35°, and 40°. For each model, shoulder ROM was evaluated at a NSA of 135° and 145°, and lateralization of 0 mm, 5 mm, and 10 mm for seven standardized movements: glenohumeral abduction, adduction, forward flexion, extension, internal rotation with the arm at 90° of abduction, as well as external rotation with the arm at 10° and 90° of abduction. Results. CSA did not seem to influence ROM in any of the models, but greater lateralization achieved greater ROM for all movements in all configurations. Internal and external rotation at 90° of abduction were impossible in most configurations, except in models with a CSA of 25°. Conclusion. Postoperative ROM following RSA depends on multiple patient and surgical factors. This study, based on computer simulation, suggests that CSA has no influence on ROM after RSA, while lateralization increases ROM in all configurations. Furthermore, increasing subacromial space is important to grant sufficient rotation at 90° of abduction. In summary, increased lateralization of the COR and increased subacromial space improve ROM in all CSA configurations. Cite this article: A. Lädermann, E. Tay, P. Collin, S. Piotton, C-H Chiu, A. Michelet, C. Charbonnier. Effect of critical shoulder angle, glenoid lateralization, and humeral inclination on range of movement in reverse shoulder arthroplasty. Bone Joint Res 2019;8:378–386. DOI: 10.1302/2046-3758.88.BJR-2018-0293.R1


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 394 - 400
1 Mar 2022
Lee KJ Kim YT Choi M Kim SH

Aims

The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears.

Methods

A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 401 - 407
1 Mar 2022
Kriechling P Zaleski M Loucas R Loucas M Fleischmann M Wieser K

Aims

The aim of this study was to report the incidence of implant-related complications, further operations, and their influence on the outcome in a series of patients who underwent primary reverse total shoulder arthroplasty (RTSA).

Methods

The prospectively collected clinical and radiological data of 797 patients who underwent 854 primary RTSAs between January 2005 and August 2018 were analyzed. The hypothesis was that the presence of complications would adversely affect the outcome. Further procedures were defined as all necessary operations, including reoperations without change of components, and partial or total revisions. The clinical outcome was evaluated using the absolute and relative Constant Scores (aCS, rCS), the Subjective Shoulder Value (SSV) scores, range of motion, and pain.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1505
1 Nov 2018
Mazhar FN Ebrahimi H Jafari D Mirzaei A

Aims. The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury. Patients and Methods. The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (. sd. 13.6) in the resection group and 36 years (. sd. 9.4) in the prosthesis group. The mean follow-up of the patients was 24.4 months (. sd. 12) in the resection group and 45.8 months (. sd. 6.8) in the prosthesis group. Outcome measures included visual analogue scale (VAS) for pain, Mayo Elbow Performance Score (MEPS), Disabilities of Arm, Shoulder and Hand (DASH) Score, and range of movement. Postoperative radiological complications were also recorded. Results. The mean ranges of extension, flexion, supination, and pronation were not significantly different between the two study groups (p = 0.75, p = 0.65, p = 0.82, and p = 0.68, respectively). The mean VAS score, DASH score, and MEPS of the two groups were also not statistically significantly different (p = 0.93, p = 0.19, and p = 0.32, respectively). At the final visit, the elbow was stable in all patients. No patient was found to have developed an Essex–Lopresti injury. Osteoarthritis grade I and II was observed in five and three patients of the resection group, respectively, and four and one patients of the arthroplasty group, respectively. Conclusion. The outcome of patients undergoing treatment for terrible triad injuries is similar whether the patient’s radial head was excised or replaced. Cite this article: Bone Joint J 2018;100-B:1499–505


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 209 - 217
1 Feb 2016
Satbhai NG Doi K Hattori Y Sakamoto S

Aims. Between 2002 and 2011, 81 patients with a traumatic total brachial plexus injury underwent reconstruction by double free muscle transfer (DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve transfers (NT, 18 cases). . Methods. They were evaluated for functional outcome and quality of life (QoL) using the Disability of Arm, Shoulder and Hand questionnaire, both pre- and post-operatively. The three groups were compared and followed-up for at least 24 months. Results. The mean shoulder abduction and flexion were comparable in all groups, but external rotation was significantly better in the DFMT group as were range and quantitative power of elbow flexion. Patients who had undergone DFMT had reasonable total active finger movement and hook grip strength. All groups showed improvement in function at a level greater than a minimum clinically important difference. The DFMT group showed the greatest improvement. Discussion. Patients in the DFMT group had a better functional outcome and QoL recovery than those in the NT and SMT groups. . Take home message: Double free muscle transfer procedure is capable of restoring maximum function in patients of total brachial plexus palsy. Cite this article: Bone Joint J 2016;97-B:209–17


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims

Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided.

Methods

This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 953 - 956
1 Jul 2018
Erşen A Atalar AC Bayram S Demirel M Tunalı O Demirhan M

Aims. The present study aimed to investigate the long-term functional results of scapulothoracic fusion using multifilament cables in patients with facioscapulohumeral dystrophy (FSHD) to identify if the early improvement from this intervention is maintained. Patients and Methods. We retrospectively investigated the long-term outcomes of 13 patients with FSHD (18 shoulders) in whom scapulothoracic fusion using multifilament cables was performed between 2004 and 2007. These patients have previously been reported at a mean of 35.5 months (24 to 87). There were eight men and five women with a mean age of 26 years. Their mean length of follow-up of our current study was 128 months (94 to 185). To evaluate long-term functional results, the range of shoulder flexion and abduction, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores were analyzed with a comparison of preoperatively, interim and at the final outcomes. The fusion was examined radiographically in all. Results. The complication rate was 33% (six of 18 scapulothoracic fusions) in 13 patients, which comprised failure of fusion in four shoulders (four patients) all occurring within the first year postoperatively. In two shoulders (one patient) wound problems arose due to attribution from the cables which required shortening but the fusion developed satisfactorily. At the final examination, the mean QuickDASH score and range of movement significantly improved in all but one patient (p < 0.001, p < 0.001 and p < 0.001). In the comparison of 13 patients’ mid- and long-term results, the mean QuickDASH score decreased from 9.8 (. sd. 6.7; 3 to 26) in the third year to 9.1 (. sd. 5.6; 3 to 22) in the tenth year (p = 0.7); the mean range of shoulder flexion and abduction decreased from 129° (. sd. 22°; 90° to 160°) and 124° (. sd. 12; 100° to 150°) at the mid-term to 103° (. sd. 12°; 80° to 120°) and 101° (. sd. 8°; 80° to 120°) at the long-term, respectively (p = 0.78 and p = 0.65). Conclusion. Scapulothoracic fusion using a multiple cabling method can confer a considerable improvement in clinical and functional outcomes for most patients with FSHD after a long follow-up period. The technique requires careful execution to avoid complications. Cite this article: Bone Joint J 2018;100-B:953–6


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 761 - 766
1 Jun 2018
Holschen M Siemes M Witt K Steinbeck J

Aims. The reasons for failure of a hemirthroplasty (HA) when used to treat a proximal humeral fracture include displaced or necrotic tuberosities, insufficient metaphyseal bone-stock, and rotator cuff tears. Reverse total shoulder arthroplasty (rTSA) is often the only remaining form of treatment in these patients. The aim of this study was to evaluate the clinical outcome after conversions from a failed HA to rTSA. Material and Methods. A total of 35 patients, in whom a HA, as treatment for a fracture of the proximal humerus, had failed, underwent conversion to a rTSA. A total of 28 were available for follow-up at a mean of 61 months (37 to 91), having been initially reviewed at a mean of 20 months (12 to 36) postoperatively. Having a convertible design, the humeral stem could be preserved in nine patients. The stem was removed in the other 19 patients and a conventional rTSA was implanted. At final follow-up, patients were assessed using the American Shoulder and Elbow Surgeons (ASES) score, the Constant Score, and plain radiographs. Results. At final follow-up, the mean ASES was 59 (25 to 97) and the mean adjusted Constant Score was 63% (23% to 109%). Both improved significantly (p < 0.001). The mean forward flexion was 104° (50° to 155°) and mean abduction was 98° (60° to 140°). Nine patients (32%) had a complication; two had an infection and instability, respectively; three had a scapular fracture; and one patient each had delayed wound healing and symptomatic loosening. If implants could be converted to a rTSA without removal of the stem, the operating time was shorter (82 minutes versus 102 minutes; p = 0.018). Conclusion. After failure of a HA in the treatment of a proximal humeral fracture, conversion to a rTSA may achieve pain relief and improved shoulder function. The complication rate is considerable. Cite this article: Bone Joint J 2018;100-B:761–6


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001). Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims

The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results.

Methods

This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 530 - 534
1 Apr 2014
Gallucci GL Piuzzi NS Slullitel PAI Boretto JG Alfie VA Donndorff A De Carli P

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment. . We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction. . Cite this article: Bone Joint J 2014;96-B:530–4


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 237 - 241
1 Feb 2014
Miyake J Shimada K Oka K Tanaka H Sugamoto K Yoshikawa H Murase T

We retrospectively assessed the value of identifying impinging osteophytes using dynamic computer simulation of CT scans of the elbow in assisting their arthroscopic removal in patients with osteoarthritis of the elbow. A total of 20 patients were treated (19 men and one woman, mean age 38 years (19 to 55)) and followed for a mean of 25 months (24 to 29). We located the impinging osteophytes dynamically using computerised three-dimensional models of the elbow based on CT data in three positions of flexion of the elbow. These were then removed arthroscopically and a capsular release was performed. The mean loss of extension improved from 23° (10° to 45°) pre-operatively to 9° (0° to 25°) post-operatively, and the mean flexion improved from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively. The mean Mayo Elbow Performance Score improved from 62 (30 to 85) to 95 (70 to 100) post-operatively. All patients had pain in the elbow pre-operatively which disappeared or decreased post-operatively. According to their Mayo scores, 14 patients had an excellent clinical outcome and six a good outcome; 15 were very satisfied and five were satisfied with their post-operative outcome. We recommend this technique in the surgical management of patients with osteoarthritis of the elbow. Cite this article: Bone Joint J 2014;96-B:237–41


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 366 - 372
1 Feb 2021
Sun Z Li J Luo G Wang F Hu Y Fan C

Aims

This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID.

Methods

A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims. We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA). Materials and Methods. We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203). Results. Aseptic loosening of the ulnar component occurred in 11 elbows. There was no radiolucency around any humeral component. There was one deep infection. The survival rate according to Kaplan-Meier survivorship analysis was 87.8% after five years and 70.7% after ten years. The range of extension/flexion was a mean -38° (-80° to 0°)/105° (30° to 150°) before surgery and -40° (-70° to -20°)/132° (100° to 150°) at the final follow-up, while the mean Mayo elbow performance score was 43 before surgery and 80 at final follow-up. Disease duration of RA up to the TEA of < 15 years and a pre-operative range of movement (ROM) of > 85° were significant risk factors for revision or aseptic loosening. Conclusion. Although Kudo type-5 prostheses gave satisfactory results in the short-term, aseptic loosening increased after five years. In most cases, elbow function was maintained in the long-term without loosening of the implant. A short duration from the onset of RA to TEA and a large pre-operative ROM were significant risk factors for revision or aseptic loosening. Cite this article: Bone Joint J 2017;99-B:818–23


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1510 - 1516
1 Nov 2016
Suter T Henninger HB Zhang Y Wylie JD Tashjian RZ

Aims. The aim of this study was to analyse the effect of altered viewing perspectives on the measurement of the glenopolar angle (GPA) and the differences between these measurements made on 3D CT reconstructions and anteroposterior (AP) scapular view radiographs. . Materials and Methods. The influence of the viewing perspective on the GPA was assessed, as were the differences in the measurements of the GPA between 3D CT reconstructions and AP scapular view radiographs in 68 cadaveric scapulae. Results. The median GPA in 3D reconstructions and AP scapular views were 42.7° (95% confidence intervals (CI), 42.0° to 43.5°) and 41.3° (95% CI 40.4° to 42.0°) respectively (p < 0.001). All but five of 20 malpositions demonstrated a significant difference in GPA compared with the respective AP scapular view (p ≤ 0.005). The GPA was most susceptible to malposition in retroversion/anteversion. Inter- and intra-observer reliability for all measurements of the GPA was excellent for 3D CT reconstructions (intraclass correlation (ICC) 0.93 (95% CI 0.87 to 0.96) and 0.94 (95% CI 0.89 to 0.97), respectively) and higher than on AP scapular radiographs (p < 0.001). The intra- and inter-observer reliability was excellent in AP scapular views and malpositions in extension/flexion (ICC ≥ 0.84) but tended to decrease with increasing viewing angle in retroversion/anteversion. Conclusion. These data suggest that 3D reconstructions are more reproducible than AP scapular radiographs in the assessment of the GPA and should be used to compare data in different studies, to predict outcome, define malunion, and act as an indication for surgery in patients with a scapular fracture. Cite this article: Bone Joint J 2016;98-B:1510–16


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 530 - 535
1 Mar 2021
Giannicola G Castagna V Villani C Gumina S Scacchi M

Aims

It has been hypothesized that proximal radial neck resorption (PRNR) following press-fit radial head arthroplasty (RHA) is due to stress-shielding. We compared two different press-fit stems by means of radiographs to investigate whether the shape and size of the stems are correlated with the degree of PRNR.

Methods

The radiographs of 52 RHAs were analyzed both at 14 days postoperatively and after two years. A cylindrical stem and a conical stem were implanted in 22 patients (group 1) and 30 patients (group 2), respectively. The PRNR was measured in the four quadrants of the radial neck and the degree of stem filling was calculated by analyzing the ratio between the prosthetic stem diameter (PSD) and the medullary canal diameter (MCD) at the proximal portion of the stem (level A), halfway along the stem length (level B), and distally at the stem tip (level C).


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims

The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis.

Methods

From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 718 - 724
1 Apr 2021
Cavalier M Johnston TR Tran L Gauci M Boileau P

Aims

The aim of this study was to identify risk factors for recurrent instability of the shoulder and assess the ability to return to sport in patients with engaging Hill-Sachs lesions treated with arthroscopic Bankart repair and Hill-Sachs remplissage (ABR-HSR).

Methods

This retrospective study included 133 consecutive patients with a mean age of 30 years (14 to 69) who underwent ABR-HSR; 103 (77%) practiced sports before the instability of the shoulder. All had large/deep, engaging Hill-Sachs lesions (Calandra III). Patients were divided into two groups: A (n = 102) with minimal or no (< 10%) glenoid bone loss, and B (n = 31) with subcritical (10% to 20%) glenoid loss. A total of 19 patients (14%) had undergone a previous stabilization, which failed. The primary endpoint was recurrent instability, with a secondary outcome of the ability to return to sport.