This study aimed to define the histopathology of degenerated humeral head cartilage and synovial inflammation of the glenohumeral joint in patients with omarthrosis (OmA) and cuff tear arthropathy (CTA). Additionally, the potential of immunohistochemical tissue biomarkers in reflecting the degeneration status of humeral head cartilage was evaluated. Specimens of the humeral head and synovial tissue from 12 patients with OmA, seven patients with CTA, and four body donors were processed histologically for examination using different histopathological scores. Osteochondral sections were immunohistochemically stained for collagen type I, collagen type II, collagen neoepitope C1,2C, collagen type X, and osteocalcin, prior to semiquantitative analysis. Matrix metalloproteinase (MMP)-1, MMP-3, and MMP-13 levels were analyzed in synovial fluid using enzyme-linked immunosorbent assay (ELISA).Aims
Methods
The zona conoidea comprises the area of the lateral
trochlear ridge of the humerus. The purpose of this study is to reintroduce
this term ‘zona conoidea’ to the discussion of the human elbow and
to investigate its significance in the development of osteoarthritis
of the elbow. The upper extremities of 12
Latissimus dorsi tendon transfer (LDTT) is technically
challenging. In order to clarify the local structural anatomy, we undertook
a morphometric study using six complete
Objectives. Cadaveric models of the shoulder evaluate discrete motion segments
using the glenohumeral joint in isolation over a defined trajectory.
The aim of this study was to design, manufacture and validate a
robotic system to accurately create three-dimensional movement of
the upper body and capture it using high-speed motion cameras. Methods. In particular, we intended to use the robotic system to simulate
the normal throwing motion in an intact
The results of a
Reverse total shoulder replacement (RTSR) depends
on adequate deltoid function for a successful outcome. However, the
anterior deltoid and/or axillary nerve may be damaged due to prior
procedures or injury. The purpose of this study was to determine
the compensatory muscle forces required for scapular plane elevation
following RTSR when the anterior deltoid is deficient. The soft
tissues were removed from six
The lateral ligament complex is the primary constraint to posterolateral rotatory laxity of the elbow, and if it is disrupted during surgery, posterolateral instability may ensue. The Wrightington approach to the head of the radius involves osteotomising the ulnar insertion of this ligament, rather than incising through it as in the classic posterolateral (Kocher) approach. In this biomechanical study of 17 human
Disorders of the pisotriquetral joint are well recognised as the cause of pain on the ulnar side of the wrist. The joint is not usually examined during routine arthroscopy because it is assumed to have a separate joint cavity to the radiocarpal joint, although there is often a connection between the two. We explored this connection during arthroscopy and in fresh-frozen
Intraspinal re-implantation after traumatic avulsion of the brachial plexus is a relatively new technique. Three different approaches to the spinal cord have been described to date, namely the posterior scapular, anterolateral interscalenic multilevel oblique corpectomy and the pure lateral. We describe an anatomical study of the pure lateral approach, based on our clinical experience and studies on
We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human
Surgical access to the head of the radius is usually performed through a lateral approach. We present an alternative technique through a modified posterior approach which was developed following dissections of 22 human
We undertook this study to determine the minimum
amount of coronoid necessary to stabilise an otherwise intact elbow
joint. Regan–Morrey types II and III, plus medial and lateral oblique
coronoid fractures, collectively termed type IV fractures, were
simulated in nine fresh
External fixation is useful for the treatment of selected injuries to the hand. Some authors have suggested that external fixation of a phalanx may tether the extensor hood, thereby hindering active movements and predisposing to permanent adhesions. There is no consensus as to the best site for placement of the pin to minimise these problems. This study was performed on
We studied the stabilising effect of prosthetic replacement of the radial head and repair of the medial collateral ligament (MCL) after excision of the radial head and section of the MCL in five
Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.Aims
Methods
Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).Objectives
Methods
Surgical treatment for traumatic, anterior glenohumeral instability requires repair of the anterior band of the inferior glenohumeral ligament, usually at the site of glenoid insertion, often combined with capsuloligamentous plication. In this study, we determined the mechanical properties of this ligament and the precise anatomy of its insertion into the glenoid in fresh-frozen glenohumeral joints of
We undertook clinical and ultrasonographic examination of the shoulders of 420 asymptomatic volunteers aged between 50 and 79 years. MRI was performed in selected cases. Full-thickness tears of the rotator cuff were detected in 32 subjects (7.6%). The prevalence increased with age as follows: 50 to 59 years, 2.1%; 60 to 69 years, 5.7%; and 70 to 79 years, 15%. The mean size of the tear was less than 3 cm and tear localisation was limited to the supraspinatus tendon in most cases (78%). The strength of flexion was reduced significantly in the group with tears (p = 0.01). Asymptomatic tears of the rotator cuff should be regarded as part of the normal ageing process in the elderly but may be less common than hitherto believed.
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
The pathogenesis of rotator cuff disease (RCD) is complex and
not fully understood. This systematic review set out to summarise
the histological and molecular changes that occur throughout the
spectrum of RCD. We conducted a systematic review of the scientific literature
with specific inclusion and exclusion criteria.Introduction
Methods
We hypothesised that a large acromial cover with
an upwardly tilted glenoid fossa would be associated with degenerative
rotator cuff tears (RCTs), and conversely, that a short acromion
with an inferiorly inclined glenoid would be associated with glenohumeral
osteoarthritis (OA). This hypothesis was tested using a new radiological parameter,
the critical shoulder angle (CSA), which combines the measurements
of inclination of the glenoid and the lateral extension of the acromion
(the acromion index). The CSA was measured on standardised radiographs of three groups:
1) a control group of 94 asymptomatic shoulders with normal rotator
cuffs and no OA; 2) a group of 102 shoulders with MRI-documented
full-thickness RCTs without OA; and 3) a group of 102 shoulders
with primary OA and no RCTs noted during total shoulder replacement.
The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0°
(29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in
the OA group. Of patients with a CSA >
35°, 84% were in the RCT
group and of those with a CSA <
30°, 93% were in the OA group. We therefore concluded that primary glenohumeral OA is associated
with significantly smaller degenerative RCTs with significantly
larger CSAs than asymptomatic shoulders without these pathologies.
These findings suggest that individual quantitative anatomy may
imply biomechanics that are likely to induce specific types of degenerative
joint disorders. Cite this article:
This study provides recommendations on the position
of the implant in reverse shoulder replacement in order to minimise
scapular notching and osteophyte formation. Radiographs from 151
patients who underwent primary reverse shoulder replacement with
a single prosthesis were analysed at a mean follow-up of 28.3 months
(24 to 44) for notching, osteophytes, the position of the glenoid
baseplate, the overhang of the glenosphere, and the prosthesis scapular
neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four
Grade 2) and 47 (31.1%) had an osteophyte. In patients without either
notching or an osteophyte the baseplate was found to be positioned
lower on the glenoid, with greater overhang of the glenosphere and
a lower PSNA than those with notching and an osteophyte. Female patients
had a higher rate of notching than males (13.3% Based on these findings we make recommendations on the placement
of the implant in both male and female patients to avoid notching
and osteophyte formation. Cite this article:
The aim of this study was to define the microcirculation of the normal rotator cuff during arthroscopic surgery and investigate whether it is altered in diseased cuff tissue. Blood flow was measured intra-operatively by laser Doppler flowmetry. We investigated six different zones of each rotator cuff during the arthroscopic examination of 56 consecutive patients undergoing investigation for impingement, cuff tears or instability; there were 336 measurements overall. The mean laser Doppler flowmetry flux was significantly higher at the edges of the tear in torn cuffs (43.1, 95% confidence interval (CI) 37.8 to 48.4) compared with normal cuffs (32.8, 95% CI 27.4 to 38.1; p = 0.0089). It was significantly lower across all anatomical locations in cuffs with impingement (25.4, 95% CI 22.4 to 28.5) compared with normal cuffs (p = 0.0196), and significantly lower in cuffs with impingement compared with torn cuffs (p <
0.0001). Laser Doppler flowmetry analysis of the rotator cuff blood supply indicated a significant difference between the vascularity of the normal and the pathological rotator cuff. We were unable to demonstrate a functional hypoperfusion area or so-called ‘critical zone’ in the normal cuff. The measured flux decreases with advancing impingement, but there is a substantial increase at the edges of rotator cuff tears. This might reflect an attempt at repair.
Contracture of the collateral ligaments is considered to be an important factor in post-traumatic stiffness of the elbow. We reviewed the results of isolated release of the medial collateral ligament in a series of 14 patients with post-traumatic loss of elbow flexion treated between 1998 and 2002. There were nine women and five men with a mean age of 45 years (17 to 76). They were reviewed at a mean follow-up of 25 months (9 to 48). The operation was performed through a longitudinal posteromedial incision centred over the ulnar nerve. After decompression of the ulnar nerve, release of the medial collateral ligament was done sequentially starting with the posterior bundle and the transverse component of the ligament, with measurement of the arc of movement after each step. If full flexion was not achieved the posterior half of the anterior bundle of the medial collateral ligament was released. At the latest follow-up, the mean flexion of the elbow improved significantly from 96° (85° to 115°) pre-operatively to 130° (110° to 150°) at final follow-up (p = 0.001). The mean extension improved significantly from 43° (5° to 90°) pre-operatively to 22° (5° to 40°) at final follow-up (p = 0.003). There was a significant improvement in the functional outcome. The mean Broberg and Morrey score increased from a mean of 54 points (29.5 to 85) pre-operatively to 87 points (57 to 99) at final follow-up (p <
0.001). All the patients had normal elbow stability. Our results indicate that partial surgical release of the medial collateral ligament is associated with improved range of movement of the elbow in patients with post-traumatic stiffness, but was less effective in controlling pain.
The sternoclavicular joint (SCJ) is a pivotal
articulation in the linked system of the upper limb girdle, providing
load-bearing in compression while resisting displacement in tension
or distraction at the manubrium sterni. The SCJ and acromioclavicular
joint (ACJ) both have a small surface area of contact protected
by an intra-articular fibrocartilaginous disc and are supported
by strong extrinsic and intrinsic capsular ligaments. The function
of load-sharing in the upper limb by bulky periscapular and thoracobrachial
muscles is extremely important to the longevity of both joints.
Ligamentous and capsular laxity changes with age, exposing both
joints to greater strain, which may explain the rising incidence
of arthritis in both with age. The incidence of arthritis in the
SCJ is less than that in the ACJ, suggesting that the extrinsic
ligaments of the SCJ provide greater stability than the coracoclavicular
ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish
from medial clavicular physeal or metaphyseal fracture-separation:
cross-sectional imaging is often required. The distinction is important
because the treatment options and outcomes of treatment are dissimilar,
whereas the treatment and outcomes of ACJ separation and fracture
of the lateral clavicle can be similar. Proper recognition and treatment
of traumatic instability is vital as these injuries may be life-threatening.
Instability of the SCJ does not always require surgical intervention.
An accurate diagnosis is required before surgery can be considered,
and we recommend the use of the Stanmore instability triangle. Most
poor outcomes result from a failure to recognise the underlying
pathology. There is a natural reluctance for orthopaedic surgeons to operate
in this area owing to unfamiliarity with, and the close proximity
of, the related vascular structures, but the interposed sternohyoid
and sternothyroid muscles are rarely injured and provide a clear
boundary to the medial retroclavicular space, as well as an anatomical
barrier to unsafe intervention. This review presents current concepts of instability of the SCJ,
describes the relevant surgical anatomy, provides a framework for
diagnosis and management, including physiotherapy, and discusses
the technical challenges of operative intervention. Cite this article:
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75)
underwent arthroscopic repair of the rotator cuff and simple tenotomy
of the long head of biceps tendon. At two years post-operatively,
ultrasound revealed that the tendon was inside the bicipital groove
in 43 patients (82.7%) and outside in nine (17.3%); in six of these
it was lying just outside the groove and in the remaining three
(5.8%) it was in a remote position with a positive Popeye Sign.
A dynamic ultrasound scan revealed that the tenotomised tendons
had adhered to the surrounding tissues (autotenodesis).The initial
condition of the tendon influenced its final position (p <
0.0005).
The presence of a Popeye sign was statistically influenced by the
pre-operative co-existence of supraspinatus and subscapularis tears (p
<
0.0001). It appears that the natural history of the tenotomised long head
of biceps tendon is to tenodese itself inside or just outside the
bicipital groove, while its pre-operative condition and coexistent
subscapularis tears play a significant role in the occurrence of
a Popeye sign.
Bone loss involving articular surface is a challenging
problem faced by the orthopaedic surgeon. In the hand and wrist,
there are articular defects that are amenable to autograft reconstruction
when primary fixation is not possible. In this article, the surgical
techniques and clinical outcomes of articular reconstructions in
the hand and wrist using non-vascularised osteochondral autografts
are reviewed.
In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the conventional radiological technique in a further 100 patients. Three orthopaedic surgeons counted the number of images without overlap between the humeral head and glenoid and calculated the amount of the glenoid surface visible in each radiograph. The analysis was repeated for intraobserver reliability. The learning curves of both techniques were studied. The amount of free visible glenoid space was significantly higher using the fulcrum-axis method (64 vs 31) and the comparable glenoid size increased significantly (8.56 vs 6.47). Thus the accuracy of the anteroposterior radiographs of the shoulder is impaired by using this technique. The intra and interobserver reliability showed a high consistency. No learning curve was observed for either technique.
The aim of this study was to compare a third-generation
cementing procedure for glenoid components with a new technique
for cement pressurisation. In 20 pairs of scapulae, 20 keeled and
20 pegged glenoid components were implanted using either a third-generation
cementing technique (group 1) or a new pressuriser (group 2). Cement penetration
was measured by three-dimensional (3D) analysis of micro-CT scans.
The mean 3D depth of penetration of the cement was significantly
greater in group 2 (p <
0.001). The mean thickness of the cement
mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and
5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm
(0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement
mantle <
2 mm was detected less frequently in group 2 (p <
0.001). Using the cement pressuriser the proportion of cement mantles
<
2 mm was significantly reduced compared with the third-generation
cementing technique.
We describe a new method of stabilising a painful unstable sternoclavicular joint using the sternocleidomastoid tendon and passing it through the medial clavicle and onto the manubrium sternum. This method is simple, reproducible and avoids the potential risks of reefing the joint to the first rib. The technique was used in seven cases of sternoclavicular joint instability in six patients who were reviewed at a mean of 39.7 months (15 to 63). Instability was markedly reduced or eliminated in all cases, but in one there was occasional persistant subluxation. There were minor scar complications after two procedures and one patient had transient ulnar neuritis. This procedure provides satisfactory results in the medium term.
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0° to 150° of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90° of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.
In light of the growing number of elderly osteopenic
patients with distal humeral fractures, we discuss the history of
their management and current trends. Under most circumstances operative
fixation and early mobilisation is the treatment of choice, as it
gives the best results. The relative indications for and results
of total elbow replacement
Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved. We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap.
This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p <
0.01). Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears.
Linburg-Comstock syndrome is characterised by an anomalous tendon slip from the flexor pollicis longus to the flexor digitorum profundus, usually of the index finger. An incidence as high as 60% to 70% has been reported. Post-traumatic inflammation of inter-tendinous connections between the flexor pollicis longus and flexor digitorum profundus, usually of the index finger, may cause unexplained chronic pain in the distal forearm. A total of 11 patients (eight females, three males), mean age 29.1 years (14 to 47) with a clinical diagnosis of Linburg-Comstock syndrome underwent surgical release of the inter-tendinous connection. The mean follow-up was for 27 months (2 to 48). Ten patients reported excellent relief of pain in the forearm, with independent flexion of flexor pollicis longus and flexor digitorum profundus to the index finger. Surgical release was an effective treatment for the Linburg-Comstock syndrome in this series.
We describe 14 patients who underwent transfer of latissimus dorsi using a new technique through a single-incision. Their mean age was 61 years (47 to 76) and the mean follow-up was 32 months (19 to 42). The mean Constant score improved from 46.5 to 74.6 points. The mean active flexion increased from 119° to 170°, mean abduction from 118° to 169° and mean external rotation from 19° to 33°. The Hornblower sign remained positive in three patients (23%) as did the external rotation lag sign also in three patients (23%). No patient had a positive drop-arm sign at follow-up. No significant difference was noted between the mean pre- and postoperative acromiohumeral distance as seen on radiographs. An increased grade of osteoarthritis was found in three patients (23%). Electromyographic analysis showed activity of the transferred muscle in all patients.
We have investigated the mid-term outcome of total shoulder replacement using a keeled cemented glenoid component and a modern cementing technique with regard to the causes of failure and loosening of the components. Between 1997 and 2003 we performed 96 total shoulder replacements on 88 patients, 24 men and 64 women with a mean age of 69.7 years (31 to 82). The minimum follow-up was five years and at the time of review 87 shoulders (77 patients) were examined at a mean follow-up of 89.1 months (60 to 127). Cumulative survival curves were generated with re-operations (accomplished and planned), survivorship of the proshesis, loosening of the glenoid (defined as tilt >
5° or subsidence >
5 mm), the presence of radiolucent lines and a Constant score of <
30 as the endpoints. There were two re-operations not involving revision of the implants and the survival rate of the prosthesis was 100.0% for the follow-up period, with an absolute Constant score of >
30 as the endpoint the survival rate was 98%. Radiological glenoid loosening was 9% after five years, and 33% after nine years. There was an incidence of 8% of radiolucent lines in more than three of six zones in the immediate post-operative period, of 37.0% after the first year which increased to 87.0% after nine years. There was no correlation between the score of Boileau and the total Constant score at the latest follow-up, but there was correlation between glenoid loosening and pain (p = 0.001). We found that total shoulder replacement had an excellent mid-term survivorship and clinical outcome. The surgical and cementing techniques were related to the decrease in radiolucent lines around the glenoid compared with earlier studies. One concern, however, was the fact that radiolucent lines increased over time and there was a rate of glenoid loosening of 9% after five years and 33% after nine years. This suggests that the design of the glenoid component, and the implantation and cementing techniques may need further improvement.
Inability to actively supinate the forearm makes common activities of daily living and certain vocational activities awkward or impossible to perform. A total of 11 patients with deficient supination of the arm underwent transfer of the tendon of flexor carpi ulnaris to the split tendon of brachioradialis with its bony insertion into the radial styloid left intact. Active supination beyond neutral rotation was a mean of 37.2° (25° to 49.5°) at a minimum follow-up of three years, representing a significant improvement (95% confidence interval 25 to 50, p <
0.001). Functional evaluation of the hand after this transfer showed excellent and good results in ten patients and fair in one. The split tendon of brachioradialis as an insertion for transfer of the flexor carpi ulnaris appears to provide adequate supination of the forearm without altering the available pronation and avoids the domination of wrist extension sometimes associated with transfers of the flexor carpi ulnaris to the radial extensors of the wrist.
We undertook a prospective study in 51 male patients aged between 17 and 27 years to ascertain whether immobilisation after primary traumatic anterior dislocation of the shoulder in external rotation was more effective than immobilisation in internal rotation in preventing recurrent dislocation in a physically active population. Of the 51 patients, 24 were randomised to be treated by a traditional brace in internal rotation and 27 were immobilised in external rotation of 15° to 20°. After immobilisation, the patients undertook a standard regime of physiotherapy and were then assessed clinically for evidence of instability. When reviewed at a mean of 33.4 months (24 to 48) ten from the external rotation group (37%) and ten from the internal rotation group (41.7%) had sustained a futher dislocation. There was no statistically significant difference (p = 0.74) between the groups. Our findings show that external rotation bracing may not be as effective as previously reported in preventing recurrent anterior dislocation of the shoulder.
In a prospective randomised study we compared the results of arthroscopic subacromial bursectomy alone with debridement of the subacromial bursa followed by acromioplasty. A total of 57 patients with a mean age of 47 years (31 to 60) suffering from primary subacromial impingement without a rupture of the rotator cuff who had failed previous conservative treatment were entered into the trial. The type of acromion was classified according to Bigliani. Patients were assessed at follow-up using the Constant score, the simple shoulder test and visual analogue scores for pain and functional impairment. One patient was lost to follow-up. At a mean follow-up of 2.5 years (1 to 5) both bursectomy and acromioplasty gave good clinical results. No statistically significant differences were found between the two treatments. The type of acromion and severity of symptoms had a greater influence on the clinical outcome than the type of treatment. As a result, we believe that primary subacromial impingement syndrome is largely an intrinsic degenerative condition rather than an extrinsic mechanical disorder.
We treated 22 patients with a diagnosis of primary frozen shoulder resistant to conservative treatment by manipulation under anaesthetic and arthroscopic release of the rotator interval, at a mean time from onset of 15 months (3 to 36). Biopsies were taken from this site and histological and immunocytochemical analysis was performed to identify the types of cell present. The tissue was characterised by the presence of fibroblasts, proliferating fibroblasts and chronic inflammatory cells. The infiltrate of chronic inflammatory cells was predominantly made up of mast cells, with T cells, B cells and macrophages also present. The pathology of frozen shoulder includes a chronic inflammatory response with fibroblastic proliferation which may be immunomodulated.
We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty. Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant complications. This procedure can restore the mechanical integrity of the proximal pole of the scaphoid satisfactorily and maintain wrist movement while avoiding the potential complications of alternative replacement arthroplasty techniques and problems associated with vascularised grafts and salvage techniques.
We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a partial tear of the subscapularis tendon. Repair was undertaken through a small deltopectoral groove approach. The mean Constant score improved in total tears from 38.7 to 89.3 points (p = 0.003) and in partial tears from 50.7 to 87.9 points (p = 0.008). The total tears were significantly more improved by surgery than the partial tears (p = 0.001). The delay between trauma and surgery was inversely proportional to the improvement in the Constant score suggesting that early diagnosis and surgical repair improves outcome.
There have been few reports in the literature of total elbow arthroplasty extending beyond 10 to 15 years. We reviewed 40 patients (41 elbows) with a mean age of 56 years (19 to 83) who had undergone a Coonrad/Coonrad-Morrey elbow arthroplasty by one surgeon for various diagnoses between 1974 and 1994. Surgical selection excluded patients with previous elbow infection or who refused to accept a sedentary level of elbow activity postoperatively. Objective data were collected from charts, radiographs, clinical photographs and supplemented by the referring orthopaedic surgeons’ records and radiographs if health or distance prevented a patient from returning for final review. Subjective outcome was defined by patient satisfaction. Of the 41 elbows, 21 were functional between 10 and 14 years after operation, ten between 15 and 19 years and ten between 20 and 31 years. There were 14 complications and 13 revisions, but no cases of acute infection, or permanent removal of any implant.
We have studied cellular and vascular changes in different stages of full thickness tears of the rotator cuff. We examined biopsies from the supraspinatus tendon in 40 patients with chronic rotator cuff tears who were undergoing surgery and compared them with biopsies from four uninjured subscapularis tendons. Morphological and immunocytochemical methods using monoclonal antibodies directed against leucocytes, macrophages, mast cells, proliferative and vascular markers were used. Histological changes indicative of repair and inflammation were most evident in small sized rotator cuff tears with increased fibroblast cellularity and intimal hyperplasia, together with increased expression of leucocyte and vascular markers. These reparative and inflammatory changes diminished as the size of the rotator cuff tear increased. Marked oedema and degeneration was seen in large and massive tears, which more often showed chondroid metaplasia and amyloid deposition. There was no association between the age of the patient and the duration of symptoms. In contrast, large and massive tears showed no increase in the number of inflammatory cells and blood vessels. Small sized rotator cuff tears retained the greatest potential to heal, showing increased fibroblast cellularity, blood vessel proliferation and the presence of a significant inflammatory component. Tissue from large and massive tears is of such a degenerative nature that it may be a significant cause of re-rupture after surgical repair and could make healing improbable in this group.
Ulnar nerve function, during and after open reduction and internal fixation of fractures of the distal humerus with subperiosteal elevation of the nerve, was assessed by intra-operative neurophysiological monitoring. Intermittent recording of the compound muscle action potentials was taken from the hypothenar muscles in 18 neurologically asymptomatic patients. The mean amplitude of the compound muscle action potential after surgery was 98.1% (