The primary aim of this prospective, multicentre study is to describe the rates of returning to golf following hip, knee, ankle, and shoulder arthroplasty in an active golfing population. Secondary aims will include determining the timing of return to golf, changes in ability, handicap, and mobility, and assessing joint-specific and health-related outcomes following surgery. This is a multicentre, prospective, longitudinal study between the Hospital for Special Surgery, (New York City, New York, USA) and Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, (Edinburgh, UK). Both centres are high-volume arthroplasty centres, specializing in upper and lower limb arthroplasty. Patients undergoing hip, knee, ankle, or shoulder arthroplasty at either centre, and who report being golfers prior to arthroplasty, will be included. Patient-reported outcome measures will be obtained at six weeks, three months, six months, and 12 months. A two-year period of recruitment will be undertaken of arthroplasty patients at both sites.Aims
Methods
A substantial fraction of patients undergoing knee arthroplasty (KA) or hip arthroplasty (HA) do not achieve an improvement as high as the minimal clinically important difference (MCID), i.e. do not achieve a meaningful improvement. Using three patient-reported outcome measures (PROMs), our aim was: 1) to assess machine learning (ML), the simple pre-surgery PROM score, and logistic-regression (LR)-derived performance in their prediction of whether patients undergoing HA or KA achieve an improvement as high or higher than a calculated MCID; and 2) to test whether ML is able to outperform LR or pre-surgery PROM scores in predictive performance. MCIDs were derived using the change difference method in a sample of 1,843 HA and 1,546 KA patients. An artificial neural network, a gradient boosting machine, least absolute shrinkage and selection operator (LASSO) regression, ridge regression, elastic net, random forest, LR, and pre-surgery PROM scores were applied to predict MCID for the following PROMs: EuroQol five-dimension, five-level questionnaire (EQ-5D-5L), EQ visual analogue scale (EQ-VAS), Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS), and Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS).Aims
Methods
The present study aimed to investigate whether patients with inflammatory bowel disease (IBD) undergoing joint arthroplasty have a higher incidence of adverse outcomes than those without IBD. A comprehensive literature search was conducted to identify eligible studies reporting postoperative outcomes in IBD patients undergoing joint arthroplasty. The primary outcomes included postoperative complications, while the secondary outcomes included unplanned readmission, length of stay (LOS), joint reoperation/implant revision, and cost of care. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were calculated using a random-effects model when heterogeneity was substantial.Aims
Methods
The extended wait that most patients are now experiencing for hip and knee arthroplasty has raised questions about whether reliance on waiting time as the primary driver for prioritization is ethical, and if other additional factors should be included in determining surgical priority. Our Prioritization of THose aWaiting hip and knee ArthroplastY (PATHWAY) project will explore which perioperative factors are important to consider when prioritizing those on the waiting list for hip and knee arthroplasty, and how these factors should be weighted. The final product will include a weighted benefit score that can be used to aid in surgical prioritization for those awaiting elective primary hip and knee arthroplasty. There will be two linked work packages focusing on opinion from key stakeholders (patients and surgeons). First, an online modified Delphi process to determine a consensus set of factors that should be involved in patient prioritization. This will be performed using standard Delphi methodology consisting of multiple rounds where following initial individual rating there is feedback, discussion, and further recommendations undertaken towards eventual consensus. The second stage will then consist of a Discrete Choice Experiment (DCE) to allow for priority setting of the factors derived from the Delphi through elicitation of weighted benefit scores. The DCE consists of several choice tasks designed to elicit stakeholder preference regarding included attributes (factors).Aims
Methods
To investigate factors that contribute to patient decisions regarding attendance for arthroplasty during the COVID-19 pandemic. A postal questionnaire was distributed to patients on the waiting list for hip or knee arthroplasty in a single tertiary centre within the UK. Patient factors that may have influenced the decision to attend for arthroplasty, global quality of life (QoL) (EuroQol five-dimension three-level (EQ-5D-3L)), and joint-specific QoL (Oxford Hip or Knee Score) were assessed. Patients were asked at which ‘COVID-alert’ level they would be willing to attend an NHS and a “COVID-light” hospital for arthroplasty. Independent predictors were assessed using multivariate logistic regression.Aims
Methods
To develop and validate patient-centred algorithms that estimate individual risk of death over the first year after elective joint arthroplasty surgery for osteoarthritis. A total of 763,213 hip and knee joint arthroplasty episodes recorded in the National Joint Registry for England and Wales (NJR) and 105,407 episodes from the Norwegian Arthroplasty Register were used to model individual mortality risk over the first year after surgery using flexible parametric survival regression.Aims
Methods
Preoperative nasal All primary total hip arthroplasties (THA) and total knee arthroplasties (TKA) performed from January 2006 to April 2018 were retrospectively reviewed for the incidence of early PJI. Demographic parameters, risk factors for PJI (American Society of Anaesthesiologists classification, body mass index, smoking status, and diabetes mellitus) and implant types were collected. A preoperative screening and eradication protocol for nasal colonization of Aims
Methods
Arthrofibrosis is a relatively common complication after joint injuries and surgery, particularly in the knee. The present study used a previously described and validated rabbit model to assess the biomechanical, histopathological, and molecular effects of the mast cell stabilizer ketotifen on surgically induced knee joint contractures in female rabbits. A group of 12 skeletally mature rabbits were randomly divided into two groups. One group received subcutaneous (SQ) saline, and a second group received SQ ketotifen injections. Biomechanical data were collected at eight, ten, 16, and 24 weeks. At the time of necropsy, posterior capsule tissue was collected for histopathological and gene expression analyses (messenger RNA (mRNA) and protein).Aims
Methods
The aim of this study was to evaluate the diagnostic accuracy of the synovial alpha-defensin enzyme-linked immunosorbent assay (ELISA) for the diagnosis of prosthetic joint infection (PJI) in the work-up prior to revision of total hip (THA) and knee arthroplasty (TKA). Inclusion criteria for this prospective cohort study were acute or chronic symptoms of the index joint without specific exclusion criteria. Synovial fluid aspirates of 202 patients were analyzed and semiquantitative laboratory alpha-defensin ELISA was performed. Final diagnosis of PJI was established by examination of samples obtained during revision surgery.Aims
Patients and Methods
We wanted to investigate regional variations in the organisms
reported to be causing peri-prosthetic infections and to report
on prophylaxis regimens currently in use across England. Analysis of data routinely collected by Public Health England’s
(PHE) national surgical site infection database on elective primary
hip and knee arthroplasty procedures between April 2010 and March
2013 to investigate regional variations in causative organisms.
A separate national survey of 145 hospital Trusts (groups of hospitals
under local management) in England routinely performing primary
hip and/or knee arthroplasty was carried out by standard email questionnaire.Objectives
Methods
Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV.Objectives
Materials and Methods
Wound complications are reported in up to 10% hip and knee arthroplasties and there is a proven association between wound complications and deep prosthetic infections. In this randomised controlled trial (RCT) we explore the potential benefits of a portable, single use, incisional negative pressure wound therapy dressing (iNPWTd) on wound exudate, length of stay (LOS), wound complications, dressing changes and cost-effectiveness following total hip and knee arthroplasties. A total of 220 patients undergoing elective primary total hip and knee arthroplasties were recruited into in a non-blinded RCT. For the final analysis there were 102 patients in the study group and 107 in the control group.Objectives
Methods
Nylon sutures and skin staples are used commonly in total knee arthroplasty (TKA) surgical wound closure. However, there is no study that compares the wound healing efficacy and patient satisfaction scores of both techniques in the same knee. We randomised 70 patients who underwent primary TKA into two groups. In one group of 34 patients, the skin at the upper half of the wound was closed with skin staples and the lower half of the wound was closed with simple interrupted nylon sutures. In the other group of 36 patients, the skin at the upper half of the wound was closed with nylon stitches and the lower half of the wound was closed with skin staples. We recorded the wound closure time, pain score at the time of stitch removal, wound complication rate, patient satisfaction score, and the Hollander wound evaluation score at the post-operative periods of five days, 14 days, six weeks, three months, and six months. Each half wound was analysed separately.Objectives
Methods
The Oxford Hip and Knee Scores (OHS, OKS) have been demonstrated
to vary according to age and gender, making it difficult to compare
results in cohorts with different demographics. The aim of this
paper was to calculate reference values for different patient groups
and highlight the concept of normative reference data to contextualise an
individual’s outcome. We accessed prospectively collected OHS and OKS data for patients
undergoing lower limb joint arthroplasty at a single orthopaedic
teaching hospital during a five-year period.
T-scores were calculated based on the OHS and OKS distributions. Objectives
Methods
To assess the responsiveness and ceiling/floor effects of the Forgotten Joint Score -12 and to compare these with that of the more widely used Oxford Hip Score (OHS) in patients six and 12 months after primary total hip arthroplasty. We prospectively collected data at six and 12 months following total hip arthroplasty from 193 patients undergoing surgery at a single centre. Ceiling effects are outlined with frequencies for patients obtaining the lowest or highest possible score. Change over time from six months to 12 months post-surgery is reported as effect size (Cohen’s d).Objectives
Methods
Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis component and the adjacent bone. Composite tibias were implanted with fixed and RP primary and revision tibial trays and biomechanically tested under up to 2.5 kN of axial compression and 10° of external femoral component rotation. Relative micromotion between the implanted tibial tray and the neighbouring bone was quantified using high-precision digital image correlation techniques.Objectives
Methods
Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters.Objectives
Methods
Patient function after arthroplasty should ideally quickly improve.
It is not known which peri-operative function assessments predict
length of stay (LOS) and short-term functional recovery. The objective
of this study was to identify peri-operative functions assessments
predictive of hospital LOS and short-term function after hospital discharge
in hip or knee arthroplasty patients. In total, 108 patients were assessed peri-operatively with the
timed-up-and-go (TUG), Iowa level of assistance scale, post-operative
quality of recovery scale, readiness for hospital discharge scale,
and the Western Ontario and McMaster Osteoarthritis Index (WOMAC).
The older Americans resources and services activities of daily living
(ADL) questionnaire (OARS) was used to assess function two weeks
after discharge. Objectives
Methods
Effective analgesia after total knee arthroplasty (TKA) improves
patient satisfaction, mobility and expedites discharge. This study
assessed whether continuous femoral nerve infusion (CFNI) was superior
to a single-shot femoral nerve block in primary TKA surgery completed
under subarachnoid blockade including morphine. We performed an adequately powered, prospective, randomised,
placebo-controlled trial comparing CFNI of 0.125% bupivacaine Objectives
Methods
Satisfaction with care is important to both patients
and to those who pay for it. The Net Promoter Score (NPS), widely
used in the service industries, has been introduced into the NHS
as the ‘friends and family test’; an overarching measure of patient
satisfaction. It assesses the likelihood of the patient recommending
the healthcare received to another, and is seen as a discriminator
of healthcare performance. We prospectively assessed 6186 individuals
undergoing primary lower limb joint replacement at a single university
hospital to determine the Net Promoter Score for joint replacements
and to evaluate which factors contributed to the response. Achieving pain relief (odds ratio (OR) 2.13, confidence interval
(CI) 1.83 to 2.49), the meeting of pre-operative expectation (OR
2.57, CI 2.24 to 2.97), and the hospital experience (OR 2.33, CI
2.03 to 2.68) are the domains that explain whether a patient would
recommend joint replacement services. These three factors, combined
with the type of surgery undertaken (OR 2.31, CI 1.68 to 3.17),
drove a predictive model that was able to explain 95% of the variation
in the patient’s recommendation response. Though intuitively similar,
this ‘recommendation’ metric was found to be materially different
to satisfaction responses. The difference between THR (NPS 71) and
TKR (NPS 49) suggests that no overarching score for a department
should be used without an adjustment for case mix. However, the
Net Promoter Score does measure a further important dimension to
our existing metrics: the patient experience of healthcare delivery. Cite this article:
Because posterior cruciate ligament (PCL) resection makes flexion
gaps wider in total knee replacement (TKR), preserving or sacrificing
a PCL affects the gap equivalence; however, there are no criteria
for the PCL resection that consider gap situations of each knee.
This study aims to investigate gap characteristics of knees and
to consider the criteria for PCL resection. The extension and flexion gaps were measured, first with the
PCL preserved and subsequently with the PCL removed (in cases in
which posterior substitute components were selected). The PCL preservation
or sacrifice was solely determined by the gap measurement results,
without considering other functions of the PCL such as ‘roll back.’Objectives
Methods
Wear debris released from bearing surfaces has been shown to
provoke negative immune responses in the recipient. Excessive wear
has been linked to early failure of prostheses. Analysis using coordinate
measuring machines (CMMs) can provide estimates of total volumetric
material loss of explanted prostheses and can help to understand
device failure. The accuracy of volumetric testing has been debated,
with some investigators stating that only protocols involving hundreds
of thousands of measurement points are sufficient. We looked to
examine this assumption and to apply the findings to the clinical
arena. We examined the effects on the calculated material loss from
a ceramic femoral head when different CMM scanning parameters were
used. Calculated wear volumes were compared with gold standard gravimetric
tests in a blinded study. Objectives
Methods