Advertisement for orthosearch.org.uk
Results 1 - 50 of 210
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 610 - 616
1 May 2018
Giannicola G Bullitta G Rotini R Murena L Blonna D Iapicca M Restuccia G Merolla G Fontana M Greco A Scacchi M Cinotti G

Aims. The aim of the study was to analyze the results of primary tendon reinsertion in acute and chronic distal triceps tendon ruptures (DTTRs) in the general population. Patients and Methods. A total of 28 patients were operated on for primary DTTR reinsertions, including 21 male patients and seven female patients with a mean age of 45 years (14 to 76). Of these patients, 23 sustained an acute DTTR and five had a chronic injury. One patient had a non-simultaneous bilateral DTTR. Seven patients had DTTR-associated ipsilateral fracture or dislocation. Comorbidities were present in four patients. Surgical treatment included transosseous and suture-anchors reinsertion in 22 and seven DTTRs, respectively. The clinical evaluation was performed using Mayo Elbow Performance Score (MEPS), the modified American Shoulder and Elbow Surgeons Score (m-ASES), the Quick Disabilities of the Arm, Shoulder and Hand score (QuickDASH), and the Medical Research Council (MRC) Scale. Results. A total of 27 patients (28 DTTRs) were available for review at a mean of 47.5 months (12 to 204). The mean MEPS, QuickDASH, and m-ASES scores were 94 (60 to 100), 10 (0 to 52), and 94 (58 to 100), respectively. Satisfactory results were observed in 26 cases (93%). Muscle strength was 5/5 and 4/5 in 18 and ten DTTRs, respectively. One patient with chronic renal failure experienced a traumatic rerupture of distal triceps. One patient (1 DTTR) experienced mild elbow stiffness. Conclusion. Primary repair of acute and chronic DTTRs in a general population yields satisfactory results in the majority of patients with a low rerupture rate. Cite this article: Bone Joint J 2018;100-B:610–16


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1074 - 1079
1 Aug 2016
Königshausen M Coulibaly MO Nicolas V Schildhauer TA Seybold D

Aims. Our aim was to investigate the outcomes of patients with a displaced fracture of the glenoid fossa who are treated conservatively. There is little information in the literature about the treatment of these rare injuries non-operatively. Patients and Methods. We reviewed 24 patients with a mean age of 52 years (19 to 81) at a mean of 5.6 years (11 months to 18 years) after the injury. Results. At final follow-up, the mean Constant and Murley score was 79 points (18 to 98); the mean Western Ontario Shoulder Instability Index score (WOSI) was 77% (12 to 100) and the mean Rowe score was 93 points (50 to 100). Fractures with little intra-articular displacement (≤ 3 mm) had an uneventful outcome. Those with intra-articular displacement of ≤ 3 mm had a significant better mean Constant and Murley score than those with displacement of ≥ 5 mm and/or a fracture gap of ≥ 5 mm. Poor clinical results such as nonunion and post-traumatic osteoarthritis were associated with displaced or angulated glenoid fragments and significant intra-articular displacement. Conclusion. Glenoid fossa fractures with displacement of ≥ 5 mm should be treated surgically if the patient’s condition allows. Displacement and angulation can lead to nonunion and a poor outcome if the degree of displacement results in a persistent fracture gap in the glenoid fossa or if the angulation of fragments leads to malunion. Cite this article: Bone Joint J 2016;98-B:1074–9


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims. The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. Methods. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision. Results. A total of 514 TEAs were included, of which 35 were revised. The five-year implant survival was 91%. Male sex, a higher BMI, and previous surgery to the same elbow showed a statistically significant association with revision (p < 0.036). Of the 35 revised implants, ten (29%) underwent a second revision. Conclusion. This study reports a five-year implant survival of TEA of 91%. Patient factors associated with revision are defined and can be used to optimize informed consent and shared decision-making. There was a high rate of secondary revisions. Cite this article: Bone Jt Open 2023;4(2):110–119


Bone & Joint Open
Vol. 4, Issue 8 | Pages 567 - 572
3 Aug 2023
Pasache Lozano RDP Valencia Ramón EA Johnston DG Trenholm JAI

Aims. The aim of this study is to evaluate the change in incidence rate of shoulder arthroplasty, indications, and surgeon volume trends associated with these procedures between January 2003 and April 2021 in the province of Nova Scotia, Canada. Methods. A total of 1,545 patients between 2005 and 2021 were analyzed. Patients operated on between 2003 and 2004 were excluded due to a lack of electronic records. Overall, 84.1% of the surgeries (n = 1,299) were performed by two fellowship-trained upper limb surgeons, with the remainder performed by one of the 14 orthopaedic surgeons working in the province. Results. Total shoulder arthroplasty (TSA) was the most frequent procedure (32.17%; n = 497), followed by stemmed hemiarthroplasty (SHA) (27.7%; n = 428). The most frequent indication for primary shoulder arthroplasty was degenerative osteoarthritis (58.1%; n = 882), followed by acute proximal humerus fracture in 15.11% (n = 245), and rotator cuff arthropathy in 14.18% (n = 220). The overall rate of revision was 7.7% (2.8% to 11.2%). The number of TSAs and reverse shoulder arthroplasties (RSAs) has been increasing since 2016. The amount of revision cases is proportional to the number of operations performed in the same year throughout the study period. Conclusion. The incidence of shoulder arthroplasty in the Maritime Provinces has increased over the last 16 years. Revision rates are similar the those found in other large database registries. Reverse shoulder arthroplasty prevalence has increased since 2016. Cite this article: Bone Jt Open 2023;4(8):567–572


Bone & Joint Open
Vol. 5, Issue 7 | Pages 534 - 542
1 Jul 2024
Woods A Howard A Peckham N Rombach I Saleh A Achten J Appelbe D Thamattore P Gwilym SE

Aims. The primary aim of this study was to assess the feasibility of recruiting and retaining patients to a patient-blinded randomized controlled trial comparing corticosteroid injection (CSI) to autologous protein solution (APS) injection for the treatment of subacromial shoulder pain in a community care setting. The study focused on recruitment rates and retention of participants throughout, and collected data on the interventions’ safety and efficacy. Methods. Participants were recruited from two community musculoskeletal treatment centres in the UK. Patients were eligible if aged 18 years or older, and had a clinical diagnosis of subacromial impingement syndrome which the treating clinician thought was suitable for treatment with a subacromial injection. Consenting patients were randomly allocated 1:1 to a patient-blinded subacromial injection of CSI (standard care) or APS. The primary outcome measures of this study relate to rates of recruitment, retention, and compliance with intervention and follow-up to determine feasibility. Secondary outcome measures relate to the safety and efficacy of the interventions. Results. A total of 53 patients were deemed eligible, and 50 patients (94%) recruited between April 2022 and October 2022. Overall, 49 patients (98%) complied with treatment. Outcome data were collected in 100% of participants at three months and 94% at six months. There were no significant adverse events. Both groups demonstrated improvement in patient-reported outcome measures over the six-month period. Conclusion. Our study shows that it is feasible to recruit to a patient-blinded randomized controlled trial comparing APS and CSI for subacromial pain in terms of clinical outcomes and health-resource use in the UK. Safety and efficacy data are presented. Cite this article: Bone Jt Open 2024;5(7):534–542


Bone & Joint Open
Vol. 3, Issue 11 | Pages 850 - 858
2 Nov 2022
Khoriati A Fozo ZA Al-Hilfi L Tennent D

Aims. The management of mid-shaft clavicle fractures (MSCFs) has evolved over the last three decades. Controversy exists over which specific fracture patterns to treat and when. This review aims to synthesize the literature in order to formulate an appropriate management algorithm for these injuries in both adolescents and adults. Methods. This is a systematic review of clinical studies comparing the outcomes of operative and nonoperative treatments for MSCFs in the past 15 years. The literature was searched using, PubMed, Google scholar, OVID Medline, and Embase. All databases were searched with identical search terms: mid-shaft clavicle fractures (± fixation) (± nonoperative). Results. Using the search criteria identified, 247 studies were deemed eligible. Following initial screening, 220 studies were excluded on the basis that they were duplicates and/or irrelevant to the research question being posed. A total of 27 full-text articles remained and were included in the final review. The majority of the meta-analyses draw the same conclusions, which are that operatively treated fractures have lower nonunion and malunion rates but that, in those fractures which unite (either operative or nonoperative), the functional outcomes are the same at six months. Conclusion. With regard to the adolescent population, the existing body of evidence is insufficient to support the use of routine operative management. Regarding adult fractures, the key to identifying patients who benefit from operative management lies in the identification of risk factors for nonunion. We present an algorithm that can be used to guide both the patient and the surgeon in a joint decision-making process, in order to optimize patient satisfaction and outcomes. Cite this article: Bone Jt Open 2022;3(11):850–858


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims. Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA). Methods. A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion. Results. RSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001). Conclusion. These findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation. Cite this article: Bone Joint J 2023;105-B(8):912–919


Bone & Joint Open
Vol. 5, Issue 7 | Pages 543 - 549
3 Jul 2024
Davies AR Sabharwal S Reilly P Sankey RA Griffiths D Archer S

Aims. Shoulder arthroplasty is effective in the management of end-stage glenohumeral joint arthritis. However, it is major surgery and patients must balance multiple factors when considering the procedure. An understanding of patients’ decision-making processes may facilitate greater support of those considering shoulder arthroplasty and inform the outcomes of future research. Methods. Participants were recruited from waiting lists of three consultant upper limb surgeons across two NHS hospitals. Semi-structured interviews were conducted with 12 participants who were awaiting elective shoulder arthroplasty. Transcribed interviews were analyzed using a grounded theory approach. Systematic coding was performed; initial codes were categorized and further developed into summary narratives through a process of discussion and refinement. Data collection and analyses continued until thematic saturation was reached. Results. Two overall categories emerged: the motivations to consider surgery, and the information participants used to inform their decision-making. Motivations were, broadly, the relief of pain and the opportunity to get on with life and regain independence. When participants’ symptoms and restrictions prevented them enjoying life to a sufficient extent, this provided the motivation to proceed with surgery. Younger participants tended to focus on maintaining employment and recreational activities, and older patients were eager to make the most of their remaining lifetime. Participants gathered information from a range of sources and were keen to optimize their recovery where possible. An important factor for participants was whether they trusted their surgeon and were prepared to delegate responsibility for elements of their care. Conclusion. Relief of pain and the opportunity to get on with life were the primary reasons to undergo shoulder arthroplasty. Participants highlighted the importance of the patient-surgeon relationship and the need for accurate information in an accessible format which is relevant to people of different ages and functional demands. Cite this article: Bone Jt Open 2024;5(7):543–549


Bone & Joint Open
Vol. 4, Issue 7 | Pages 478 - 489
1 Jul 2023
Tennent D Antonios T Arnander M Ejindu V Papadakos N Rastogi A Pearse Y

Aims. Glenoid bone loss is a significant problem in the management of shoulder instability. The threshold at which the bone loss is considered “critical” requiring bony reconstruction has steadily dropped and is now approximately 15%. This necessitates accurate measurement in order that the correct operation is performed. CT scanning is the most commonly used modality and there are a number of techniques described to measure the bone loss however few have been validated. The aim of this study was to assess the accuracy of the most commonly used techniques for measuring glenoid bone loss on CT. Methods. Anatomically accurate models with known glenoid diameter and degree of bone loss were used to determine the mathematical and statistical accuracy of six of the most commonly described techniques (relative diameter, linear ipsilateral circle of best fit (COBF), linear contralateral COBF, Pico, Sugaya, and circle line methods). The models were prepared at 13.8%, 17.6%, and 22.9% bone loss. Sequential CT scans were taken and randomized. Blinded reviewers made repeated measurements using the different techniques with a threshold for theoretical bone grafting set at 15%. Results. At 13.8%, only the Pico technique measured under the threshold. At 17.6% and 22.9% bone loss all techniques measured above the threshold. The Pico technique was 97.1% accurate, but had a high false-negative rate and poor sensitivity underestimating the need for grafting. The Sugaya technique had 100% specificity but 25% of the measurements were incorrectly above the threshold. A contralateral COBF underestimates the area by 16% and the diameter by 5 to 7%. Conclusion. No one method stands out as being truly accurate and clinicians need to be aware of the limitations of their chosen technique. They are not interchangeable, and caution must be used when reading the literature as comparisons are not reliable. Cite this article: Bone Jt Open 2023;4(7):478–489


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims. Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research. Methods. A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review. Results. A total of 362 studies met the inclusion criteria. Most were of total elbow arthroplasty (246; 68%), followed by radial head arthroplasty (100; 28%), distal humeral hemiarthroplasty (11; 3%), and radiocapitellar arthroplasty (5; 1%). Most were retrospective (326; 90%) and observational (315; 87%). The median sample size for all types of implant across all studies was 36 (interquartile range (IQR) 21 to 75). The median length of follow-up for all studies was 56 months (IQR 36 to 81). A total of 583 unique outcome descriptors were used and were categorized into 18 domains. A total of 105 instruments were used to measure 39 outcomes. Conclusion. We found that most of the literature dealing with elbow arthroplasty consists of retrospective observational studies with small sample sizes and short follow-up. Many outcomes have been used with many different instruments for their measurement, indicating a need to define a core set of outcomes and instruments for future research in this area. Cite this article: Bone Joint J 2022;104-B(10):1148–1155


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims. There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA). Methods. We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal. Results. The mean MEPS significantly improved from 47 (15 to 70) points preoperatively to 95 (70 to 100) points at final follow-up (p < 0.001). Complications were noted in six elbows (23%) in six patients, and of these, four with an ulnar neuropathy and one elbow with postoperative traumatic fracture required additional surgeries. There was no revision with implant removal, and there was no radiological evidence of loosening around the components. With any revision surgery as the endpoint, the survival rates up to 25 years were 78.1% (95% confidence interval 52.8 to 90.6) as determined by Kaplan-Meier analysis. Conclusion. The clinical outcome of primary unlinked TEA for young patients with RA was satisfactory and comparable with that for elderly patients. A favourable survival rate without implant removal might support the use of unlinked devices for young patients with this disease entity, with a caution of a relatively high complication rate regarding ulnar neuropathy. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Jt Open 2023;4(1):19–26


Bone & Joint Open
Vol. 3, Issue 10 | Pages 826 - 831
28 Oct 2022
Jukes C Dirckx M Bellringer S Chaundy W Phadnis J

Aims. The conventionally described mechanism of distal biceps tendon rupture (DBTR) is of a ‘considerable extension force suddenly applied to a resisting, actively flexed forearm’. This has been commonly paraphrased as an ‘eccentric contracture to a flexed elbow’. Both definitions have been frequently used in the literature with little objective analysis or citation. The aim of the present study was to use video footage of real time distal biceps ruptures to revisit and objectively define the mechanism of injury. Methods. An online search identified 61 videos reporting a DBTR. Videos were independently reviewed by three surgeons to assess forearm rotation, elbow flexion, shoulder position, and type of muscle contraction being exerted at the time of rupture. Prospective data on mechanism of injury and arm position was also collected concurrently for 22 consecutive patients diagnosed with an acute DBTR in order to corroborate the video analysis. Results. Four videos were excluded, leaving 57 for final analysis. Mechanisms of injury included deadlift, bicep curls, calisthenics, arm wrestling, heavy lifting, and boxing. In all, 98% of ruptures occurred with the arm in supination and 89% occurred at 0° to 10° of elbow flexion. Regarding muscle activity, 88% occurred during isometric contraction, 7% during eccentric contraction, and 5% during concentric contraction. Interobserver correlation scores were calculated as 0.66 to 0.89 using the free-marginal Fleiss Kappa tool. The prospectively collected patient data was consistent with the video analysis, with 82% of injuries occurring in supination and 95% in relative elbow extension. Conclusion. Contrary to the classically described injury mechanism, in this study the usual arm position during DBTR was forearm supination and elbow extension, and the muscle contraction was typically isometric. This was demonstrated for both video analysis and ‘real’ patients across a range of activities leading to rupture. Cite this article: Bone Jt Open 2022;3(10):826–831


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims. Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty. Methods. This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates. Results. A total of 13 studies (919 shoulders) were included in the analysis. The mean age of patients at initial evaluation was 72.2 years (42 to 87), with a mean follow-up time of 40.7 months (24 to 120). Nine studies with 292 rTSAs evaluated the use of bone graft and five studies with 627 rTSAs evaluated the use of augmented glenoid baseplates. One study was analyzed in both groups. Both techniques demonstrated improvement in patient-reported outcome measures and ROM assessment, with augmented prostheses outperforming bone grafting on improvements in the American Shoulder and Elbow Surgeons Score. There was a higher complication rate (8.9% vs 3.5%; p < 0.001) and revision rate among the bone grafting group compared with the patients who were treated with augmented prostheses (2.4% vs 0.6%; p = 0.022). Conclusion. This review provides strong evidence that both bone graft and augmented glenoid baseplate techniques to address glenoid bone loss give excellent ROM and functional outcomes in primary rTSA. The use of augmented base plates may confer fewer complications and revisions. Cite this article: Bone Joint J 2022;104-B(12):1334–1342


Bone & Joint Open
Vol. 3, Issue 10 | Pages 815 - 825
20 Oct 2022
Athanatos L Kulkarni K Tunnicliffe H Samaras M Singh HP Armstrong AL

Aims. There remains a lack of consensus regarding the management of chronic anterior sternoclavicular joint (SCJ) instability. This study aimed to assess whether a standardized treatment algorithm (incorporating physiotherapy and surgery and based on the presence of trauma) could successfully guide management and reduce the number needing surgery. Methods. Patients with chronic anterior SCJ instability managed between April 2007 and April 2019 with a standardized treatment algorithm were divided into non-traumatic (offered physiotherapy) and traumatic (offered surgery) groups and evaluated at discharge. Subsequently, midterm outcomes were assessed via a postal questionnaire with a subjective SCJ stability score, Oxford Shoulder Instability Score (OSIS, adapted for the SCJ), and pain visual analogue scale (VAS), with analysis on an intention-to-treat basis. Results. A total of 47 patients (50 SCJs, three bilateral) responded for 75% return rate. Of these, 31 SCJs were treated with physiotherapy and 19 with surgery. Overall, 96% (48/50) achieved a stable SCJ, with 60% (30/50) achieving unrestricted function. In terms of outcomes, 82% (41/50) recorded good-to-excellent OSIS scores (84% (26/31) physiotherapy, 79% (15/19) surgery), and 76% (38/50) reported low pain VAS scores at final follow-up. Complications of the total surgical cohort included a 19% (5/27) revision rate, 11% (3/27) frozen shoulder, and 4% (1/27) scar sensitivity. Conclusion. This is the largest midterm series reporting chronic anterior SCJ instability outcomes when managed according to a standardized treatment algorithm that emphasizes the importance of appropriate patient selection for either physiotherapy or surgery, based on a history of trauma. All but two patients achieved a stable SCJ, with stability maintained at a median of 70 months (11 to 116) for the physiotherapy group and 87 months (6 to 144) for the surgery group. Cite this article: Bone Jt Open 2022;3(10):815–825


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims. This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate. Methods. We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view. Results. There were no significant differences in the initial preoperative demographic characteristics. In both groups, there were significant improvements in postoperative clinical scores (p < 0.001). However, most clinical outcomes, including range of motion measurements (forward elevation, external rotation, internal rotation, and abduction), showed no differences between the pre- and postoperative values. Comparing the postoperative outcomes of both groups, no further improvement from biceps augmentation was found. Group B, although not reaching statistical significance, had more re-tears than group A (30% vs 15%; p = 0.117). Conclusion. In LMRCTs, biceps augmentation provided no significant improvement of an incomplete repair. Therefore, biceps augmentation is not recommended in the treatment of LMRCTs. Cite this article: Bone Joint J 2022;104-B(11):1234–1241


Bone & Joint Open
Vol. 3, Issue 9 | Pages 701 - 709
2 Sep 2022
Thompson H Brealey S Cook E Hadi S Khan SHM Rangan A

Aims. To achieve expert clinical consensus in the delivery of hydrodilatation for the treatment of primary frozen shoulder to inform clinical practice and the design of an intervention for evaluation. Methods. We conducted a two-stage, electronic questionnaire-based, modified Delphi survey of shoulder experts in the UK NHS. Round one required positive, negative, or neutral ratings about hydrodilatation. In round two, each participant was reminded of their round one responses and the modal (or ‘group’) response from all participants. This allowed participants to modify their responses in round two. We proposed respectively mandating or encouraging elements of hydrodilatation with 100% and 90% positive consensus, and respectively disallowing or discouraging with 90% and 80% negative consensus. Other elements would be optional. Results. Between 4 August 2020 and 4 August 2021, shoulder experts from 47 hospitals in the UK completed the study. There were 106 participants (consultant upper limb orthopaedic surgeons, n = 50; consultant radiologists, n = 52; consultant physiotherapist, n = 1; extended scope physiotherapists, n = 3) who completed round one, of whom 97 (92%) completed round two. No elements of hydrodilatation were “mandated” (100% positive rating). Elements that were “encouraged” (≥ 80% positive rating) were the use of image guidance, local anaesthetic, normal saline, and steroids to deliver the injection. Injecting according to patient tolerance, physiotherapy, and home exercises were also “encouraged”. No elements were “discouraged” (≥ 80% negative rating) although using hypertonic saline was rated as being “disallowed” (≥ 90% negative rating). Conclusion. In the absence of rigorous evidence, our Delphi study allowed us to achieve expert consensus about positive, negative, and neutral ratings of hydrodilatation in the management of frozen shoulder in a hospital setting. This should inform clinical practice and the design of an intervention for evaluation. Cite this article: Bone Jt Open 2022;3(9):701–709


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims. The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance. Methods. A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated. Results. The mean follow-up was six years (2 to 14). PRNR started after a mean of 7.5 weeks (SD 2.1) and progressed significantly during the first two years, by the end of which the bone resorption stabilized. PRNR was detected in 81% (n = 45) of patients in Group 1 and 88% (n = 36) in Group 2. The final mean PRNR was 3.0 mm (SD 2.3) in Group 1 and 3.7 mm (SD 2.5) in Group 2. The mean MEPS, QuickDASH, and pASES-E were 95.9 (SD 11.5), 4.4 (SD 9.2), and 94.8 (SD 10.9) in Group 1 and 92.2 (SD 16.2), 9.9 (SD 21.5), and 90.8 (SD 15) in Group 2, respectively. No significant differences were observed between groups in the clinical and radiological outcomes. No correlations were found between PRNR and the clinical results. Conclusion. PRNR after press-fit RHA is a common radiological finding that develops in the first 24 months before stabilizing definitively. PRNR does not affect the clinical results or implant survival in the mid term. Cite this article: Bone Joint J 2023;105-B(8):905–911


Bone & Joint Research
Vol. 13, Issue 8 | Pages 392 - 400
5 Aug 2024
Barakat A Evans J Gibbons C Singh HP

Aims. The Oxford Shoulder Score (OSS) is a 12-item measure commonly used for the assessment of shoulder surgeries. This study explores whether computerized adaptive testing (CAT) provides a shortened, individually tailored questionnaire while maintaining test accuracy. Methods. A total of 16,238 preoperative OSS were available in the National Joint Registry (NJR) for England, Wales, Northern Ireland, the Isle of Man, and the States of Guernsey dataset (April 2012 to April 2022). Prior to CAT, the foundational item response theory (IRT) assumptions of unidimensionality, monotonicity, and local independence were established. CAT compared sequential item selection with stopping criteria set at standard error (SE) < 0.32 and SE < 0.45 (equivalent to reliability coefficients of 0.90 and 0.80) to full-length patient-reported outcome measure (PROM) precision. Results. Confirmatory factor analysis (CFA) for unidimensionality exhibited satisfactory fit with root mean square standardized residual (RSMSR) of 0.06 (cut-off ≤ 0.08) but not with comparative fit index (CFI) of 0.85 or Tucker-Lewis index (TLI) of 0.82 (cut-off > 0.90). Monotonicity, measured by H value, yielded 0.482, signifying good monotonic trends. Local independence was generally met, with Yen’s Q3 statistic > 0.2 for most items. The median item count for completing the CAT simulation with a SE of 0.32 was 3 (IQR 3 to 12), while for a SE of 0.45 it was 2 (IQR 2 to 6). This constituted only 25% and 16%, respectively, when compared to the 12-item full-length questionnaire. Conclusion. Calibrating IRT for the OSS has resulted in the development of an efficient and shortened CAT while maintaining accuracy and reliability. Through the reduction of redundant items and implementation of a standardized measurement scale, our study highlights a promising approach to alleviate time burden and potentially enhance compliance with these widely used outcome measures. Cite this article: Bone Joint Res 2024;13(8):392–400


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims. The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. Methods. This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). Results. Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. Conclusion. In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes. Cite this article: Bone Joint J 2023;105-B(11):1189–1195


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims. Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm. Methods. An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score. Results. Of the 18 patients (nine male, nine female) who met the inclusion criteria, the median follow-up was 8.5 years (interquartile range (IQR) 5.6 to 10). Their mean age was 49 years (SD 11). The mean extension improved significantly from 38° (SD 15°) to 24° (SD 9°) (p = 0.027), with a mean flexion-extension arc change from 81° (SD 27°) to 93° (SD 30°) (p = 0.172) but with no forearm rotational improvement (p = 0.233) at latest follow-up. The QuickDASH functional score improved significantly from 80 (SD 14) to 52 (SD 26) following reconstruction (p = 0.031), but generally the level of disability remains high. Radiological assessment showed no progression of proximal migration of the radius, with a stable interbutton distance and ulnar variance from immediate postoperative radiograph to the latest follow-up. Conclusion. Central band interosseus membrane reconstruction using a synthetic braided cross-linked graft can improve patient-rated arm function and range of motion, but significant functional deficits remain in patients with chronic injuries. Cite this article: Bone Joint J 2024;106-B(2):182–188


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 663 - 667
1 Jun 2023
Youn S Rhee SM Cho S Kim C Lee J Rhee YG

Aims. The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the rotator cuff defect. Methods. A total of 99 patients who underwent treatment between December 2013 and August 2019 were retrospectively reviewed. Visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) scores were reviewed pre- and postoperatively according to the location, size, physical characteristics, and radiological features of the calcific deposits. Additionally, the influence of any residual calcific deposits shown on postoperative radiographs was explored. The healing rate of the unrepaired cuff defect was determined by reviewing the 29 patients who had follow-up MRIs. Results. Statistically significant improvement from pre- to postoperation was seen in all VAS and ASES scores for each group, but no statistical differences were seen between the postoperative scores according to the differences in the features of the calcific deposits. When residual calcification was observed postoperatively, the mean ASES and VAS (rest) scores improved significantly to 95.0 (SD 5.6) and 0.0 (SD 0.0), respectively (p = 0.006 and p < 0.001), and did not differ from those who had the complete removal. Of 29 patients who had follow-up MRIs, six (20.7%) showed signs of an interstitial tear. This group’s mean postoperative ASES and VAS (rest) scores improved to excellent levels of 96.0 (SD 3.7) and 0.0 (SD 0.0), respectively, and were similar to those of the 23 patients with normal MRI appearances. Conclusion. Arthroscopic removal of calcific deposits without repairing the rotator cuff defect resulted in significant improvement in function and pain level, regardless of the deposit’s location, size, type, and whether or not complete excision was achieved. Despite leaving the defects unrepaired, in the limited number of patients with follow-up MRIs, 23 of 29 patients (79.3%) showed good healing, and the rest, who had persistent signs of interstitial defects on the MRIs, still had excellent outcomes. The removal of calcific deposits without repairing the cuff defects provided excellent outcomes. Cite this article: Bone Joint J 2023;105-B(6):663–667


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims. The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years. Methods. All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders. Results. In total, 3,902 rTSAs were included. A deltopectoral approach was used in 54% (2,099/3,902) and an anterosuperior approach in 46% (1,803/3,902). Overall, the mean age in the cohort was 75 years (50 to 96) and the most common indication for rTSA was cuff tear arthropathy (35%; n = 1,375), followed by osteoarthritis (29%; n = 1,126), acute fracture (13%; n = 517), post-traumatic sequelae (10%; n = 398), and an irreparable cuff rupture (5%; n = 199). The two high-volume centres performed the anterosuperior approach more often compared to the medium- and low-volume centres (p < 0.001). Of the 3,902 rTSAs, 187 were revised (5%), resulting in a five-year survival of 95.4% (95% confidence interval 94.7 to 96.0; 3,137 at risk). The most common reason for revision was a periprosthetic joint infection (35%; n = 65), followed by instability (25%; n = 46) and loosening (25%; n = 46). After correcting for relevant confounders, the revision rate for glenoid loosening, instability, and the overall implant survival did not differ significantly between the two approaches (p = 0.494, p = 0.826, and p = 0.101, respectively). Conclusion. The surgical approach used for rTSA did not influence the overall implant survival or the revision rate for instability or glenoid loosening. Cite this article: Bone Joint J 2023;105-B(9):1000–1006


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims. Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries. Methods. A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis. Results. A total of 18 patients (0.5%) had a proximal humeral fracture and clinical evidence of vascular compromise, giving an annual incidence of 0.29 per 100,000 of the population. Their mean age was 68.7 years (45 to 92) and ten (56%) were female. Evidence of a mixed pattern neurological deficit (brachial plexus palsy) (odds ratio (OR) 380.6 (95% CI 85.9 to 1,685.8); p < 0.001), complete separation of the proximal shaft from the humeral head with medial displacement (OR 39.5 (95% CI 14.0 to 111.8); p < 0.001), and a fracture-dislocation (OR 5.0 (95% CI 1.6 to 15.3); p = 0.015) were all associated with an increased risk of associated vascular compromise. A policy of reduction and fixation of the fracture prior to vascular surgical intervention had favourable outcomes without vascular sequelae. Conclusion. The classic signs of distal ischaemia are often absent in patients with proximal injuries to major vessels. We were able to identify specific clinical and radiological ‘red flags’ which, particularly when present in combination, should increase the suspicion of a fracture with an associated vascular injury, and facilitate early diagnosis and appropriate combined orthopaedic and vascular intervention. Cite this article: Bone Joint J 2024;106-B(8):842–848


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 174 - 181
1 Feb 2024
Mandalia KP Brodeur PG Li LT Ives K Cruz Jr. AI Shah SS

Aims. The aim of this study was to characterize the influence of social deprivation on the rate of complications, readmissions, and revisions following primary total shoulder arthroplasty (TSA), using the Social Deprivation Index (SDI). The SDI is a composite measurement, in percentages, of seven demographic characteristics: living in poverty, with < 12 years of education, single-parent households, living in rented or overcrowded housing, households without a car, and unemployed adults aged < 65 years. Methods. Patients aged ≥ 40 years, who underwent primary TSA between 2011 and 2017, were identified using International Classification of Diseases (ICD)-9 Clinical Modification and ICD-10 procedure codes for TSA in the New York Statewide Planning and Research Cooperative System database. Readmission, reoperation, and other complications were analyzed using multivariable Cox proportional hazards regression controlling for SDI, age, ethnicity, insurance status, and Charlson Comorbidity Index. Results. A total of 17,698 patients with a mean age of 69 years (SD 9.6), of whom 57.7% were female, underwent TSA during this time and 4,020 (22.7%) had at least one complication. A total of 8,113 patients (45.8%) had at least one comorbidity, and the median SDI in those who developed complications 12 months postoperatively was significantly greater than in those without a complication (33 vs 38; p < 0.001). Patients from areas with higher deprivation had increased one-, three-, and 12-month rates of readmission, dislocation, humeral fracture, urinary tract infection, deep vein thrombosis, and wound complications, as well as a higher three-month rate of pulmonary embolism (all p < 0.05). Conclusion. Beyond medical complications, we found that patients with increased social deprivation had higher rates of humeral fracture and dislocation following primary TSA. The large sample size of this study, and the outcomes that were measured, add to the literature greatly in comparison with other large database studies involving TSA. These findings allow orthopaedic surgeons practising in under-served or low-volume areas to identify patients who may be at greater risk of developing complications. Cite this article: Bone Joint J 2024;106-B(2):174–181


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims. The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. Methods. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). Results. Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). Conclusion. These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids. Cite this article: Bone Joint J 2023;105-B(6):668–678


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 389 - 399
15 Mar 2023
Makaram NS Nicholson JA Yapp LZ Gillespie M Shah CP Robinson CM

Aims. The open Latarjet procedure is a widely used treatment for recurrent anterior instability of the shoulder. Although satisfactory outcomes are reported, factors which influence a patient’s experience are poorly quantified. The aim of this study was to evaluate the effect of a range of demographic factors and measures of the severity of instability on patient-reported outcome measures in patients who underwent an open Latarjet procedure at a minimum follow-up of two years. Methods. A total of 350 patients with anterior instability of the shoulder who underwent an open Latarjet procedure between 2005 and 2018 were reviewed prospectively, with the collection of demographic and psychosocial data, preoperative CT, and complications during follow-up of two years. The primary outcome measure was the Western Ontario Shoulder Instability Index (WOSI), assessed preoperatively, at two years postoperatively, and at mid-term follow-up at a mean of 50.6 months (SD 24.8) postoperatively. The secondary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. The influence of the demographic details of the patients, measurements of the severity of instability, and the complications of surgery were assessed in a multivariate analysis. Results. The mean age of the patients was 25.5 years (22 to 32) and 27 (7.7%) were female. The median time to surgery after injury was 19 months (interquartile range (IQR) 13 to 39). Seven patients developed clinically significant complications requiring further intervention within two years of surgery. The median percentage WOSI deficiency was 8.0% (IQR 4 to 20) and median QuickDASH was 3.0 (IQR 0 to 9) at mid-term assessment. A minority of patients reported a poorer experience, and 22 (6.3%) had a > 50% deficiency in WOSI score. Multivariate analysis revealed that consumption of ≥ 20 units of alcohol/week, a pre-existing affective disorder or epilepsy, medicolegal litigation, increasing time to surgery, and residing in a more socioeconomically deprived area were independently predictive of a poorer WOSI score. Conclusion. Although most patients treated by an open Latarjet procedure have excellent outcomes at mid-term follow-up, a minority have poorer outcomes, which are mainly predictable from pre-existing demographic factors, rather than measures of the severity of instability. Cite this article: Bone Joint J 2023;105-B(4):389–399


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims. This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA). Methods. From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery. Results. There were no significant differences in demographic data and preoperative characteristics between the two groups. Both groups showed significant improvements in patient-reported outcome measures (visual analogue scale for pain, visual analogue scale for function, American Shoulder and Elbow Surgeons, Constant, and Simple Shoulder Test scores) from preoperative to final assessment (p < 0.001). However, AGB showed no additional benefit. Notably, within range of motion, Group B showed significant postoperative decrease in both external rotation and internal rotation, unlike Group A (p = 0.028 and 0.003, respectively). Both groups demonstrated a significant correction of superior-inclination after surgery, while patients in Group B exhibited a significant decrease in LHO postoperatively (p = 0.001). Regarding complications, Group A experienced more acromial stress fractures (3 cases; 12.5%), whereas Group B had a higher occurrence of scapular notching (24 cases; 33.3%) (p = 0.008). Conclusion. Both eccentric reaming with STB and off-axis reaming with AGB are effective methods for addressing superior glenoid wear in RSA, leading to improved clinical outcomes. However, it is important to be aware of the potential risks associated with eccentric reaming, which include excessive bone loss leading to reduced rotation and scapular notching. Cite this article: Bone Joint J 2024;106-B(3):268–276


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results. A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion. The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface. Cite this article: Bone Joint J 2024;106-B(5):482–491


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 534 - 542
1 May 2023
Makaram NS Khan LAK Jenkins PJ Robinson CM

Aims. The outcomes following nonoperative management of minimally displaced greater tuberosity (GT) fractures, and the factors which influence patient experience, remain poorly defined. We assessed the early patient-derived outcomes following these injuries and examined the effect of a range of demographic- and injury-related variables on these outcomes. Methods. In total, 101 patients (53 female, 48 male) with a mean age of 50.9 years (19 to 76) with minimally displaced GT fractures were recruited to a prospective observational cohort study. During the first year after injury, patients underwent experiential assessment using the Disabilities of the Arm, Shoulder and Hand (DASH) score and assessment of associated injuries using MRI performed within two weeks of injury. The primary outcome was the one-year DASH score. Multivariate analysis was used to assess the effect of patient demographic factors, complications, and associated injuries, on outcome. Results. The mean DASH score improved from 42.3 (SD 9.6) at six weeks post-injury, to 19.5 (SD 14.3) at one-year follow-up (p < 0.001), but outcomes were mixed, with 30 patients having a DASH score > 30 at one year. MRI revealed a range of associated injuries, with a full-thickness rotator cuff tear present in 19 patients (19%). Overall, 11 patients (11%) developed complications requiring further operative intervention; 20 patients (21%) developed post-traumatic secondary shoulder stiffness. Multivariate analysis revealed a high-energy mechanism (p = 0.009), tobacco consumption (p = 0.033), use of mobility aids (p = 0.047), a full-thickness rotator cuff tear (p = 0.002), and the development of post-traumatic secondary shoulder stiffness (p = 0.035) were independent predictors of poorer outcome. Conclusion. The results of nonoperative management of minimally displaced GT fractures are heterogeneous. While many patients have satisfactory early outcomes, a substantial subgroup fare much worse. There is a high prevalence of rotator cuff injuries and post-traumatic shoulder stiffness, and their presence is associated with poorer patient experience. Furthermore, patients who have a high-energy injury, smoke, or use walking aids, have worse outcomes. Cite this article: Bone Joint J 2023;105-B(5):534–542


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims. Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE. Methods. This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates. Results. Compared with non-stiff aTSAs, stiff aTSAs had poorer passive FE and active external rotation (ER), whereas there were no significant postoperative differences between stiff rTSAs and non-stiff rTSAs. There were no significant differences in preoperative function when comparing stiff aTSAs with stiff rTSAs. However, stiff rTSAs had significantly greater postoperative active and passive FE (p = 0.001 and 0.004, respectively), and active abduction (p = 0.001) compared with stiff aTSAs. The outcome scores were significantly more favourable in stiff rTSAs for the Shoulder Pain and Disability Index, Simple Shoulder Test, American Shoulder and Elbow Surgeons score, University of California, Los Angeles score, and the Constant score, compared with stiff aTSAs. When comparing the proportion of stiff aTSAs versus stiff rTSAs that exceeded the minimal clinically important difference and substantial clinical benefit, stiff rTSAs achieved both at greater rates for all measurements except active ER. The complication rate did not significantly differ between stiff aTSAs and stiff rTSAs, but there was a significantly higher rate of revision surgery in stiff aTSAs (p = 0.007). Conclusion. Postoperative overhead ROM, outcome scores, and rates of revision surgery favour the use of a rTSA rather than aTSA in patients with glenohumeral OA, an intact rotator cuff and limited FE, with similar rotational ROM in these two groups. Cite this article: Bone Joint J 2023;105-B(12):1303–1313


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 56 - 63
1 Jan 2023
de Klerk HH Oosterhoff JHF Schoolmeesters B Nieboer P Eygendaal D Jaarsma RL IJpma FFA van den Bekerom MPJ Doornberg JN

Aims. This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons?. Methods. A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment. Results. Accuracy significantly improved with 3D-printed models for the whole group on pattern recognition (acc. 2D/3D. = 0.62 vs acc. 3Dprint. = 0.69; Δacc = 0.07 (95% confidence interval (CI) 0.00 to 0.14); p = 0.025). A significant improvement was also seen in reliability for pattern recognition with the additional 3D-printed models (κ. 2D/3D. = 0.41 (moderate) vs κ. 3Dprint. = 0.59 (moderate); Δκ = 0.18 (95% CI 0.14 to 0.22); p ≤ 0.001). Accuracy was comparable between junior and senior surgeons with the 3D-printed model (acc. junior. = 0.70 vs acc. senior. = 0.68; Δacc = -0.02 (95% CI -0.17 to 0.13); p = 0.904). Reliability was also comparable between junior and senior surgeons without the 3D-printed model (κ. junior. = 0.39 (fair) vs κ. senior. = 0.43 (moderate); Δκ = 0.03 (95% CI -0.03 to 0.10); p = 0.318). However, junior surgeons showed greater improvement regarding reliability than seniors with 3D-printed models (κ. junior. = 0.65 (substantial) vs κ. senior. = 0.54 (moderate); Δκ = 0.11 (95% CI 0.04 to 0.18); p = 0.002). Conclusion. The use of 3D-printed models significantly improved the accuracy and reliability of recognizing the pattern of complex fractures of the elbow. However, the current long printing time and non-reusable materials could limit the usefulness of 3D-printed models in clinical practice. They could be suitable as a reusable tool for teaching residents. Cite this article: Bone Joint J 2023;105-B(1):56–63


Bone & Joint Open
Vol. 3, Issue 6 | Pages 463 - 469
7 Jun 2022
Vetter P Magosch P Habermeyer P

Aims. The aim of this study was to determine whether there is a correlation between the grade of humeral osteoarthritis (OA) and the severity of glenoid morphology according to Walch. We hypothesized that there would be a correlation. Methods. Overal, 143 shoulders in 135 patients (73 females, 62 males) undergoing shoulder arthroplasty surgery for primary glenohumeral OA were included consecutively. Mean age was 69.3 years (47 to 85). Humeral head (HH), osteophyte length (OL), and morphology (transverse decentering of the apex, transverse, or coronal asphericity) on radiographs were correlated to the glenoid morphology according to Walch (A1, A2, B1, B2, B3), glenoid retroversion, and humeral subluxation on CT images. Results. Increased humeral OL correlated with a higher grade of glenoid morphology (A1-A2-B1-B2-B3) according to Walch (r = 0.672; p < 0.0001). It also correlated with glenoid retroversion (r = 0.707; p < 0.0001), and posterior humeral subluxation (r = 0.452; p < 0.0001). A higher humeral OL (odds ratio (OR) 1.17; 95% confidence interval (CI) 1.03 to 1.32; p = 0.013), posterior humeral subluxation (OR 1.11; 95% CI 1.01 to 1.22; p = 0.031), and glenoid retroversion (OR 1.48; 95% CI 1.30 to 1.68; p < 0.001) were independent factors for a higher glenoid morphology. More specifically, a humeral OL of ≥ 13 mm was indicative of eccentric glenoid types B2 and B3 (OR 14.20; 95% CI 5.96 to 33.85). Presence of an aspherical HH in the coronal plane was suggestive of glenoid types B2 and B3 (OR 3.34; 95% CI 1.67 to 6.68). Conclusion. The criteria of humeral OL and HH morphology are associated with increasing glenoid retroversion, posterior humeral subluxation, and eccentric glenoid wear. Therefore, humeral radiological parameters might hint at the morphology on the glenoid side. Cite this article: Bone Jt Open 2022;3(6):463–469


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 620 - 626
1 May 2022
Stadecker M Gu A Ramamurti P Fassihi SC Wei C Agarwal AR Bovonratwet P Srikumaran U

Aims. Corticosteroid injections are often used to manage glenohumeral arthritis in patients who may be candidates for future total shoulder arthroplasty (TSA) or reverse shoulder arthroplasty (rTSA). In the conservative management of these patients, corticosteroid injections are often provided for symptomatic relief. The purpose of this study was to determine if the timing of corticosteroid injections prior to TSA or rTSA is associated with changes in rates of revision and periprosthetic joint infection (PJI) following these procedures. Methods. Data were collected from a national insurance database from January 2006 to December 2017. Patients who underwent shoulder corticosteroid injection within one year prior to ipsilateral TSA or rTSA were identified and stratified into the following cohorts: < three months, three to six months, six to nine months, and nine to 12 months from time of corticosteroid injection to TSA or rTSA. A control cohort with no corticosteroid injection within one year prior to TSA or rTSA was used for comparison. Univariate and multivariate analyses were conducted to determine the association between specific time intervals and outcomes. Results. In total, 4,252 patients were included in this study. Among those, 1,632 patients (38.4%) received corticosteroid injection(s) within one year prior to TSA or rTSA and 2,620 patients (61.6%) did not. On multivariate analysis, patients who received corticosteroid injection < three months prior to TSA or rTSA were at significantly increased risk for revision (odds ratio (OR) 2.61 (95% confidence interval (CI) 1.77 to 3.28); p < 0.001) when compared with the control cohort. However, there was no significant increase in revision risk for all other timing interval cohorts. Notably, Charlson Comorbidity Index ≥ 3 was a significant independent risk factor for all-cause revision (OR 4.00 (95% CI 1.40 to 8.92); p = 0.036). Conclusion. There is a time-dependent relationship between the preoperative timing of corticosteroid injection and the incidence of all-cause revision surgery following TSA or rTSA. This analysis suggests that an interval of at least three months should be maintained between corticosteroid injection and TSA or rTSA to minimize risks of subsequent revision surgery. Cite this article: Bone Joint J 2022;104-B(5):620–626


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims. The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow. Methods. We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation. Results. BMI, the duration of stiffness, the preoperative ROM, the preoperative intensity of pain, and grade of post-traumatic osteoarthritis of the elbow were identified as predictors of outcome and incorporated to construct the nomogram. SPESSO displayed good discrimination with a C-index of 0.73 (95% confidence interval 0.64 to 0.81). A high C-index value of 0.70 could still be reached in the interval validation. The calibration graph showed good agreement between the nomogram prediction and the outcome. Conclusion. The newly developed SPESSO is a valid and convenient model which can be used to predict the outcome of open arthrolysis of the elbow. It could assist clinicians in counselling patients regarding the choice and expectations of treatment. Cite this article: Bone Joint J 2022;104-B(4):486–494


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 479 - 485
1 Apr 2022
Baker M Albelo F Zhang T Schneider MB Foster MJ Aneizi A Hasan SA Gilotra MN Henn RF

Aims. The purpose of this study was to assess the prevalence of depression and anxiety symptoms in patients undergoing shoulder surgery using the National Institutes of Health (NIH) Patient-Reported Outcomes Measurement Information System (PROMIS) Depression and Anxiety computer adaptive tests, and to determine the factors associated with more severe symptoms. Additionally, we sought to determine whether PROMIS Depression and Anxiety were associated with functional outcomes after shoulder surgery. Methods. This was a retrospective analysis of 293 patients from an urban population who underwent elective shoulder surgery from 2015 to 2018. Survey questionnaires included preoperative and two-year postoperative data. Bivariate analysis was used to identify associations and multivariable analysis was used to control for confounding variables. Results. Mean two-year PROMIS Depression and Anxiety scores significantly improved from preoperative scores, with a greater improvement observed in PROMIS Anxiety. Worse PROMIS Depression and Anxiety scores were also significantly correlated with worse PROMIS Physical Function (PF) and American Shoulder and Elbow Surgeons scores (ASES). After controlling for confounding variables, worse PROMIS Depression was an independent predictor of worse PROMIS PF, while worse PROMIS Anxiety was an independent predictor of worse PROMIS PF and ASES scores. Conclusion. Mean two-year PROMIS Depression and Anxiety scores improved after elective shoulder surgery and several patient characteristics were associated with these scores. Worse functional outcomes were associated with worse PROMIS Depression and Anxiety; however, more severe two-year PROMIS Anxiety was the strongest predictor of worse functional outcomes. Cite this article: Bone Joint J 2022;104-B(4):479–485


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 401 - 407
1 Mar 2022
Kriechling P Zaleski M Loucas R Loucas M Fleischmann M Wieser K

Aims. The aim of this study was to report the incidence of implant-related complications, further operations, and their influence on the outcome in a series of patients who underwent primary reverse total shoulder arthroplasty (RTSA). Methods. The prospectively collected clinical and radiological data of 797 patients who underwent 854 primary RTSAs between January 2005 and August 2018 were analyzed. The hypothesis was that the presence of complications would adversely affect the outcome. Further procedures were defined as all necessary operations, including reoperations without change of components, and partial or total revisions. The clinical outcome was evaluated using the absolute and relative Constant Scores (aCS, rCS), the Subjective Shoulder Value (SSV) scores, range of motion, and pain. Results. The overall surgical site complication rate was 22% (188 complications) in 152 patients (156 RTSAs; 18%) at a mean follow-up of 46 months (0 to 169). The most common complications were acromial fracture (in 44 patients, 45 RTSAs; 5.3%), glenoid loosening (in 37 patients, 37 RTSAs; 4.3%), instability (in 23 patients, 23 RTSAs; 2.7%), humeral fracture or loosening of the humeral component (in 21 patients, 21 RTSAs; 2.5%), and periprosthetic infection (in 14 patients, 14 RTSAs; 1.6%). Further surgery was undertaken in 79 patients (82 RTSAs) requiring a total of 135 procedures (41% revision rate). The most common indications for further surgery were glenoid-related complications (in 23 patients, 23 RTSAs; 2.7%), instability (in 15 patients, 15 RTSAs; 1.8%), acromial fractures (in 11 patients, 11 RTSAs; 1.3%), pain and severe scarring (in 13 patients, 13 RTSAs; 1.5%), and infection (in 8 patients, 8 RTSAs; 0.9%). Patients who had a complication had significantly worse mean rCS scores (57% (SD 24%) vs 81% (SD 16%)) and SSV scores (53% (SD 27%) vs 80% (SD 20%)) compared with those without a complication. If revision surgery was necessary, the outcome was even further compromised (mean rCS score: 51% (SD 23%) vs 63% (SD 23%); SSV score: 4% (SD 25%) vs 61% (SD 27%). Conclusion. Although the indications for, and use of, a RTSA are increasing, it remains a demanding surgical procedure. We found that about one in five patients had a complication and one in ten required further surgery. Both adversely affected the outcome. Cite this article: Bone Joint J 2022;104-B(3):401–407


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 394 - 400
1 Mar 2022
Lee KJ Kim YT Choi M Kim SH

Aims. The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears. Methods. A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI. Results. Patients in group RL were significantly older than in group L (p = 0.008), and group RL was significantly associated with female sex (odds ratio 2.5 (95% confidence interval 1.03 to 6.32); p = 0.041). Mean postoperative pain visual analogue scale (VAS) score was significantly greater (group L = 0.8 (SD 1.5), group RL = 1.7 (SD 2.2); p = 0.033) and mean postoperative American Shoulder and Elbow Surgeons (ASES) score was significantly lower in group RL than group L (group L = 91.4 (SD 13.1), group RL = 83.8 (SD 17.9); p = 0.028). However, postoperative mean VAS for pain and ASES score were not lower than the patient-acceptable symptom state scores. Mean retracted tear length was significantly larger in group L (group L = 24.6 mm (SD 6.5), group RL = 20.0 mm (SD 6.8); p = 0.003). Overall re-tear rate for 82 tears was 11.0% (nine shoulders), and re-tear rates in group L and RL were similar at 11.1% (four shoulders) and 10.9% (five shoulders), respectively (p = 1.000). No significant intergroup difference was found for fatty degeneration (FD) or muscle atrophy. Within group L, postoperative FD grades of supraspinatus and subscapularis worsened significantly (p = 0.034 and p = 0.008, respectively). Mean postoperative pain VAS (male = 1.2 (SD 1.8), female = 1.3 (SD 2.0)) and ASES scores (male = 88.7 (SD 15.5), female = 86.0 (SD 16.8)) were similar in male and female patients (p = 0.700 and p = 0.475, respectively). Regression analysis showed age was not a prognostic factor of postoperative pain VAS or ASES scores (p = 0.188 and p = 0.150, respectively). Conclusion. Older age and female sex were associated with reverse L-shaped tears. Although the postoperative functional outcomes of patients with reverse L-shaped tears were satisfactory, the clinical scores were poorer than those of patients with L-shaped tears. Surgeons should be aware of the differences in clinical outcome between L-shaped and reverse L-shaped rotator cuff tears. Cite this article: Bone Joint J 2022;104-B(3):394–400


Bone & Joint Open
Vol. 4, Issue 3 | Pages 205 - 209
16 Mar 2023
Jump CM Mati W Maley A Taylor R Gratrix K Blundell C Lane S Solanki N Khan M Choudhry M Shetty V Malik RA Charalambous CP

Aims

Frozen shoulder is a common, painful condition that results in impairment of function. Corticosteroid injections are commonly used for frozen shoulder and can be given as glenohumeral joint (GHJ) injection or suprascapular nerve block (SSNB). Both injection types have been shown to significantly improve shoulder pain and range of motion. It is not currently known which is superior in terms of relieving patients’ symptoms. This is the protocol for a randomized clinical trial to investigate the clinical effectiveness of corticosteroid injection given as either a GHJ injection or SSNB.

Methods

The Therapeutic Injections For Frozen Shoulder (TIFFS) study is a single centre, parallel, two-arm, randomized clinical trial. Participants will be allocated on a 1:1 basis to either a GHJ corticosteroid injection or SSNB. Participants in both trial arms will then receive physiotherapy as normal for frozen shoulder. The primary analysis will compare the Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include OSS at six and 12 months, range of shoulder movement at three months, and Numeric Pain Rating Scale, abbreviated Disabilities of Arm, Shoulder and Hand score, and EuroQol five-level five-dimension health index at three months, six months, and one year after injection. A minimum of 40 patients will be recruited to obtain 80% power to detect a minimally important difference of ten points on the OSS between the groups at three months after injection. The study is registered under ClinicalTrials.gov with the identifier NCT04965376.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims. Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided. Methods. This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively. Results. There was significant improvement in the mean OSS from 24.7 (SD 5.4) preoperatively to 42.0 (SD 6.3) at one year, and this improvement was maintained at 9.1 years (p < 0.001), with a score of 42.8 (SD 6.8). Similar significant improvements in the pain score were seen and maintained at the final follow-up from 6.1 (SD 1.6) to 2.1 (SD 2.3) (p < 0.001). There were also significant improvements in the ROM of the shoulder, and patient satisfaction was high. Conclusion. The use of an interposition human dermal allograft in patients with an irreparable rotator cuff tear leads to good outcomes that are maintained at a mean of nine years postoperatively. Cite this article: Bone Joint J 2022;104-B(1):91–96


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 76 - 82
1 Jan 2022
ten Brinke B Hesseling B Eygendaal D Hoelen MA Mathijssen NMC

Aims. Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. Methods. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Results. At two years, median translation along the x-, y-, and z-axis was -0.12 mm (interquartile range (IQR) -0.18 to 0.02), -0.17 mm (IQR -0.27 to -0.09), and 0.09 mm (IQR 0.02 to 0.31). Median rotation around the x-, y-, and z-axis was 0.12° (IQR -0.50 to 0.57), -0.98° (IQR -1.83 to 1.23), and 0.09° (IQR -0.76 to 0.30). Overall, 20 prostheses stabilized within 12 months postoperatively. Four prostheses showed continuous migration between 12 and 24 months. At two-year follow-up, with the exception of one revised prosthesis, all clinical scores improved significantly (median VAS difference at rest: -3.0 (IQR -1.5 to -6.0); OSS 22.0 (IQR 15.0 to 25.0); CMS 29.5 (IQR 15.0 to 35.75); and DASH -30.0 (IQR -20.6 to -41.67) (all p < 0.001)) with the exception of one revised prosthesis. Conclusion. In conclusion, we found that 20 out of 24 implants stabilized within 12 months postoperatively. The significance of continuous migration in four implants is unclear and future research on the predictive value of early migration for future loosening in TSA is required. Clinical results revealed a clinically relevant improvement. Cite this article: Bone Joint J 2022;104-B(1):76–82


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 83 - 90
1 Jan 2022
Batten TJ Gallacher S Evans JP Harding RJ Kitson J Smith CD Thomas WJ

Aims. The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Methods. Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening. Results. Mean OSS at mean follow-up of 6.67 years (5.0 to 10.74) was 40.12 (9 to 48), with no statistically significant difference between those implanted for a non-OA indication and those for OA (p = 0.056) or time-dependent deterioration between two years and five years (p = 0.206). Ranges of motion significantly improved compared with preoperative findings and were maintained between two and five years with a mean external rotation of 38° (SD 18.1, 0 to 100) and forward elevation of 152° (SD 29.9, 90 to 180). Of those components with radiographs suitable for analysis (n = 83), 23 (28%) were found to have a least one humeral radiolucent line, which were predominantly incomplete, less than 2 mm, and in a single anatomical zone. No humeral components were loose. A radiolucent line was present around 22 (15%) of glenoid components, and 15 (10%) of components had failed. Rotator cuff failure was found in 21 (15%) components. The mean time to either glenoid or rotator cuff failure was greater than three years following implantation. Survivorship was 96.4% (95% CI 91.6 to 98.5, number at risk 128) at five years, and 94.3% (95% CI 88.2 to 97.3, number at risk 76) at seven years, both of which compare favourably with best results taken from available registries. Conclusion. Functional and radiological outcomes of the Eclipse stemless TSA are excellent, with no loose humeral components at minimum five-year follow-up. The presence of radiolucent lines is of interest and requires long-term observation but does not impact on the clinical results. Of the eight revisions required, this was predominantly for glenoid and rotator cuff failure. Cite this article: Bone Joint J 2022;104-B(1):83–90


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1717 - 1724
1 Nov 2021
Singh HP Haque A Taub N Modi A Armstrong A Rangan A Pandey R

Aims. The main objective of this study was to examine whether the Oxford Shoulder Score (OSS) demonstrated floor or ceiling effects when used to measure outcomes following shoulder arthroplasty in a large national cohort. Secondary objectives were to assess its pain and function subscales, and to identify independent predictors for patients achieving a postoperative ceiling score following shoulder arthroplasty. Methods. Secondary database analysis of the National Joint Registry (NJR), which included 48,270 patients undergoing shoulder arthroplasty, was conducted. The primary outcome measure was the OSS. Secondary outcome measures were the OSS-Function Component Subscale and OSS-Pain Component Subscale. Floor and ceiling effects were considered to be present if > 15% of patients scored either the lowest or highest possible score. Logistic regression analysis was used to identify independent predictors for scoring the highest possible OSS score postoperatively. Results. Preoperatively, 1% of patients achieved the lowest possible OSS score (0) and 0.4% of patients achieved the highest possible score (48). Postoperatively, < 1% of patients achieved the lowest score at all timepoints, but the percentage achieving the highest score at six months was 8.3%, at three years 16.9%, and at five years 17%. Male patients, those aged between 60 and 89 years, and those undergoing an anatomical total shoulder arthroplasty (ATSA) were more likely to contribute to the ceiling effect seen in the OSS questionnaire. Pain and function subscales exhibited greater ceiling effects at three years and five years when compared with the overall OSS questionnaire. Logistic regression analysis showed that sex, procedure type, and preoperative OSS score were independent predictors for scoring the highest possible OSS at years. Conclusion. Based on NJR patient-reported outcome measures data, the OSS does not exhibit a ceiling effect at six months, but does at three years and five years, in part due to outcome scores of ATSA. Preoperative OSS, age, male sex, and ATSA are independent predictors of achieving a ceiling score. Cite this article: Bone Joint J 2021;103-B(11):1717–1724


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims. The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results. Methods. This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included. Results. All patients underwent more than two years of follow-up (mean 33.5 months (24 to 45)). All clinical scores were also improved at two-year follow-up (mean visual analogue scale 0.7 (SD 0.5) vs 6.1 (SD 1.2); p < 0.001; mean American Shoulder and Elbow Surgeons score 93.5 (SD 5.3) vs 42.5 (SD 10.8); p < 0.001; mean University of California, Los Angeles score, 31.7 (SD 3.7) vs 12.0 (SD 3.1); p < 0.001; and mean Constant-Murley score 88.7 (SD 3.5) vs 43.3 (SD 10.9); p < 0.001), and 24 of 26 fascia lata grafts were fully healed on MRI (92%). One patient had haematoma formation at the harvesting side of the fascia lata at two days postoperatively. Conclusion. The fascia lata autograft bridging repair combined with artificial ligament internal brace reinforcement technique achieved good functional outcomes, with a high rate of graft healing at two-year follow-up. Although the short-term results are promising, further studies with a greater number of patients would provide clearer results. Cite this article: Bone Joint J 2021;103-B(10):1619–1626


Aims. To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component. Methods. Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed. Results. A total of 93 patients were randomized (46 TM; 47 POLY). No significant or clinically important differences were found with patient-reported outcomes at 24-month follow-up. Regarding the glenoid components, there were no complications or revision surgeries in either group. Grade 1 metal debris was observed in three (6.5%) patients with TM glenoids at 24 months but outcomes were not negatively impacted. Conclusion. Early results from this RCT showed no differences in disease-specific QOL, radiographs, complication rates, or shoulder function between uncemented second-generation TM and cemented POLY glenoids at 24 months postoperatively. Revision surgeries and reoperations were reported in both groups, but none attributed to glenoid implant failure. At 24 months postoperatively, Grade 1 metal debris was found in 6.5% of patients with a TM glenoid but did not negatively influence patient-reported outcomes. Longer-term follow-up is needed and is underway. Cite this article: Bone Jt Open 2021;2(9):728–736


Bone & Joint Open
Vol. 2, Issue 9 | Pages 773 - 784
1 Sep 2021
Rex SS Kottam L McDaid C Brealey S Dias J Hewitt CE Keding A Lamb SE Wright K Rangan A

Aims. This systematic review places a recently completed multicentre randomized controlled trial (RCT), UK FROST, in the context of existing randomized evidence for the management of primary frozen shoulder. UK FROST compared the effectiveness of pre-specified physiotherapy techniques with a steroid injection (PTSI), manipulation under anaesthesia (MUA) with a steroid injection, and arthroscopic capsular release (ACR). This review updates a 2012 review focusing on the effectiveness of MUA, ACR, hydrodilatation, and PTSI. Methods. MEDLINE, Embase, PEDro, Science Citation Index, Clinicaltrials.gov, CENTRAL, and the World Health Organization (WHO) International Clinical Trials Registry were searched up to December 2018. Reference lists of included studies were screened. No language restrictions applied. Eligible studies were RCTs comparing the effectiveness of MUA, ACR, PTSI, and hydrodilatation against each other, or supportive care or no treatment, for the management of primary frozen shoulder. Results. Nine RCTs were included. The primary outcome of patient-reported shoulder function at long-term follow-up (> 6 months and ≤ 12 months) was reported for five treatment comparisons across four studies. Standardized mean differences (SMD) were: ACR versus MUA: 0.21 (95% confidence interval (CI) 0.00 to 0.42), ACR versus supportive care: -0.13 (95% CI -1.10 to 0.83), and ACR versus PTSI: 0.33 (95% CI 0.07 to 0.59) and 0.25 (95% CI -0.34 to 0.85), all favouring ACR; MUA versus supportive care: 0 (95% CI -0.44 to 0.44) not favouring either; and MUA versus PTSI: 0.12 (95% CI -0.14 to 0.37) favouring MUA. None of these differences met the threshold of clinical significance agreed for the UK FROST and most confidence intervals included zero. Conclusion. The findings from a recent multicentre RCT provided the strongest evidence that, when compared with each other, neither PTSI, MUA, nor ACR are clinically superior. Evidence from smaller RCTs did not change this conclusion. The effectiveness of hydrodilatation based on four RCTs was inconclusive and there remains an evidence gap. Cite this article: Bone Jt Open 2021;2(9):773–784


Bone & Joint Open
Vol. 2, Issue 8 | Pages 685 - 695
2 Aug 2021
Corbacho B Brealey S Keding A Richardson G Torgerson D Hewitt C McDaid C Rangan A

Aims. A pragmatic multicentre randomized controlled trial, UK FROzen Shoulder Trial (UK FROST), was conducted in the UK NHS comparing the cost-effectiveness of commonly used treatments for adults with primary frozen shoulder in secondary care. Methods. A cost utility analysis from the NHS perspective was performed. Differences between manipulation under anaesthesia (MUA), arthroscopic capsular release (ACR), and early structured physiotherapy plus steroid injection (ESP) in costs (2018 GBP price base) and quality adjusted life years (QALYs) at one year were used to estimate the cost-effectiveness of the treatments using regression methods. Results. ACR was £1,734 more costly than ESP ((95% confidence intervals (CIs) £1,529 to £1,938)) and £1,457 more costly than MUA (95% CI £1,283 to £1,632). MUA was £276 (95% CI £66 to £487) more expensive than ESP. Overall, ACR had worse QALYs compared with MUA (-0.0293; 95% CI -0.0616 to 0.0030) and MUA had better QALYs compared with ESP (0.0396; 95% CI -0.0008 to 0.0800). At a £20,000 per QALY willingness-to-pay threshold, MUA had the highest probability of being cost-effective (0.8632) then ESP (0.1366) and ACR (0.0002). The results were robust to sensitivity analyses. Conclusion. While ESP was less costly, MUA was the most cost-effective option. ACR was not cost-effective. Cite this article: Bone Jt Open 2021;2(8):685–695


Bone & Joint Open
Vol. 2, Issue 7 | Pages 552 - 561
28 Jul 2021
Werthel J Boux de Casson F Burdin V Athwal GS Favard L Chaoui J Walch G

Aims. The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts. Methods. In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary osteoarthritis (OA). The four rotator cuff muscles were manually segmented and their volume, including intramuscular fat, was calculated. The normalized volume (NV) of each muscle was calculated by dividing muscle volume to the patient’s scapular bone volume. Muscle volume and percentage of muscle atrophy were compared between muscles and between cohorts. Results. Rotator cuff muscle volume was significantly decreased in patients with OA, CTA, and IRCT compared to healthy patients (p < 0.0001). Atrophy was comparable for all muscles between CTA, IRCT, and OA patients, except for the supraspinatus, which was significantly more atrophied in CTA and IRCT (p = 0.002). In healthy shoulders, the anterior cuff represented 45% of the entire cuff, while the posterior cuff represented 40%. A similar partition between anterior and posterior cuff was also found in both CTA and IRCT patients. However, in OA patients, the relative volume of the anterior (42%) and posterior cuff (45%) were similar. Conclusion. This study shows that rotator cuff muscle volume is significantly decreased in patients with OA, CTA, or IRCT compared to healthy patients, but that only minimal differences can be observed between the different pathological groups. This suggests that the influence of rotator cuff muscle volume and atrophy (including intramuscular fat) as an independent factor of outcome may be overestimated. Cite this article: Bone Jt Open 2021;2(7):552–561


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1333 - 1338
2 Aug 2021
Kankanalu P Borton ZM Morgan ML Cresswell T Espag MP Tambe AA Clark DI

Aims. Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. Methods. All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up. Results. The implant was revised in ten shoulders (5.2%) with a median time to revision of 21.2 months (interquartile range (IQR) 9.9 to 41.8). The Kaplan-Meier survivorship estimate at seven years was 95.9% (95% confidence interval (CI) 91.7 to 98; 35 RTSAs at risk) for aseptic mechanical failure of the glenoid and 94.8% (95% CI 77.5 to 96.3; 35 RTSAs at risk) for all-cause revision. Minimum five-year clinical and radiological outcomes were available for 103 and 98 RTSAs respectively with a median follow-up time of six years (IQR 5.2 to 7.0). Median postoperative Oxford Shoulder Score was 38 (IQR 31 to 45); median Constant and Murley score was 60 (IQR 47.5 to 70); median forward flexion 115° (IQR 100° to 125°); median abduction 95° (IQR 80° to 120°); and external rotation 25° (IQR 15° to 40°) Scapular notching was seen in 62 RTSAs (63.2%). Conclusion. We present the largest and longest-term series of TM-backed glenoid implants demonstrating 94.8% all-cause survivorship at seven years. Specifically pertaining to glenoid loosening, survival of the implant increased to 95.9%. In addition, we report satisfactory minimum five-year clinical and radiological outcomes. Cite this article: Bone Joint J 2021;103-B(8):1333–1338


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1292 - 1300
1 Jul 2021
Märtens N Heinze M Awiszus F Bertrand J Lohmann CH Berth A

Aims. The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. Methods. A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted. Results. The ROM (p < 0.001), CS (p < 0.001), and DASH score (p < 0.001) showed significant improvements after shoulder arthroplasty for both implants. There were no differences between the groups treated with stemmed or stemless shoulder prosthesis with respect to the mean CS (79.2 (35 to 118) vs 74.4 (31 to 99); p = 0.519) and DASH scores (11.4 (8 to 29) vs 13.2 (7 to 23); p = 0.210). The ten-year unadjusted cumulative survival rate was 95.3% for the stemmed anatomical shoulder prosthesis and 91.5% for the stemless shoulder prosthesis and did not differ between the treatment groups (p = 0.251). The radiological evaluation of the humeral components in both groups did not show loosening of the humeral implant. The main reason for revision for each type of arthroplasties were complications related to the glenoid. Conclusion. The use of anatomical stemless shoulder prosthesis yielded good and reliable results and did not differ from anatomical stemmed shoulder prosthesis over a mean period of ten years. The differences in periprosthetic humeral bone adaptations between both implants have no clinical impact during the follow-up. Cite this article: Bone Joint J 2021;103-B(7):1292–1300


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1284 - 1291
1 Jul 2021
Carter TH Karunaratne BJ Oliver WM Murray IR White TO Reid JT Duckworth AD

Aims. Acute distal biceps tendon repair reduces fatigue-related pain and minimizes loss of supination of the forearm and strength of flexion of the elbow. We report the short- and long-term outcome following repair using fixation with a cortical button techqniue. Methods. Between October 2010 and July 2018, 102 patients with a mean age of 43 years (19 to 67), including 101 males, underwent distal biceps tendon repair less than six weeks after the injury, using cortical button fixation. The primary short-term outcome measure was the rate of complications. The primary long-term outcome measure was the abbreviated Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. Secondary outcomes included the Oxford Elbow Score (OES), EuroQol five-dimension three-level score (EQ-5D-3L), satisfaction, and return to function. Results. Eight patients (7.8%) had a major complication and 34 (33.3%) had a minor complication. Major complications included re-rupture (n = 3; 2.9%), unrecovered nerve injury (n = 4; 3.9%), and surgery for heterotopic ossification (n = 1; 1.0%). Three patients (2.9%) overall required further surgery for a complication. Minor complications included neurapraxia (n = 27; 26.5%) and superficial infection (n = 7; 6.9%). A total of 33 nerve injuries occurred in 31 patients (30.4%). At a mean follow-up of five years (1 to 9.8) outcomes were available for 86 patients (84.3%). The median QuickDASH, OES, EQ-5D-3L, and satisfaction scores were 1.2 (IQR 0 to 5.1), 48 (IQR 46 to 48), 0.80 (IQR 0.72 to 1.0), and 100/100 (IQR 90 to 100), respectively. Most patients were able to return to work (81/83, 97.6%) and sport (51/62,82.3%). Unrecovered nerve injury was associated with an inferior outcome according to the QuickDASH (p = 0.005), OES (p = 0.004), EQ-5D-3L (p = 0.010), and satisfaction (p = 0.024). Multiple linear regression analysis identified an unrecovered nerve injury to be strongly associated with an inferior outcome according to the QuickDASH score (p < 0.001), along with infection (p < 0.001), although re-rupture (p = 0.440) and further surgery (p = 0.652) were not. Conclusion. Acute distal biceps tendon repair using cortical button fixation was found to result in excellent patient-reported outcomes and health-related quality of life. Although rare, unrecovered nerve injury adversely affects outcome. Cite this article: Bone Joint J 2021;103-B(7):1284–1291