Advertisement for orthosearch.org.uk
Results 1 - 26 of 26
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1257 - 1263
1 Sep 2015
Sheps DM Bouliane M Styles-Tripp F Beaupre LA Saraswat MK Luciak-Corea C Silveira A Glasgow R Balyk R

This study compared the clinical outcomes following mini-open rotator cuff repair (MORCR) between early mobilisation and usual care, involving initial immobilisation. In total, 189 patients with radiologically-confirmed full-thickness rotator cuff tears underwent MORCR and were randomised to either early mobilisation (n = 97) or standard rehabilitation (n = 92) groups. Patients were assessed at six weeks and three, six, 12 and 24 months post-operatively. Six-week range of movement comparisons demonstrated significantly increased abduction (p = 0.002) and scapular plane elevation (p = 0.006) in the early mobilisation group, an effect which was not detectable at three months (p > 0.51) or afterwards. At 24 months post-operatively, patients who performed pain-free, early active mobilisation for activities of daily living showed no difference in clinical outcomes from patients immobilised for six weeks following MORCR. We suggest that the choice of rehabilitation regime following MORCR may be left to the discretion of the patient and the treating surgeon. Cite this article: Bone Joint J 2015;97-B:1257–63


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 530 - 534
1 Apr 2014
Gallucci GL Piuzzi NS Slullitel PAI Boretto JG Alfie VA Donndorff A De Carli P

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment. . We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction. . Cite this article: Bone Joint J 2014;96-B:530–4


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1521 - 1525
1 Nov 2016
Su Y Nan G

Aims. Cubitus varus is the most common late complication of a supracondylar fracture of the humerus in children. Correction can be performed using one of a number of techniques of osteotomy but each has disadvantages. We describe a new technique for correcting post-traumatic cubitus varus using a lateral closing wedge isosceles triangular osteotomy. Patients and Methods. A lateral closing wedge isosceles triangular osteotomy was performed in 25 patients (15 male and ten female with a mean age of 9.5 years (6 to 12)) between May 2010 and April 2013. All patients had cubitus varus secondary to malunion of a supracondylar fracture, with good function of the elbow and a full range of movement. The osteotomy lines were marked on the bone with an isosceles triangular template made before surgery, after which the osteotomy was performed leaving the medial cortex intact. Fixation was performed using two lateral 2 mm Kirschner (K)-wires and patients were immobilised in an above-elbow plaster. By six to eight weeks callus was present and the wires and cast were removed. Patients were reviewed at four and six weeks, three, six and 12 months and then every two years until skeletal maturity. Clinical and radiographic outcomes were categorised as excellent, good or poor. Results. A total of 23 patients had an excellent and two had a good outcome at a mean final follow-up of 3.4 years (two to four). The mean post-operative carrying angle in the corrected elbow was 11.7° (7° to 18°). One patient fell, displacing the osteotomy, and needed revision of the fixation. No patient had a nerve injury. Conclusion. A lateral isosceles triangular osteotomy and with K-wire fixation is a practical, effective, reliable, safe and simple method of correcting post-traumatic cubitus varus in children. It has inherent stability and excellent cosmesis without prominence of the lateral condyle. . Cite this article: Bone Joint J 2016;98-B:1521–5


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1197 - 1203
1 Sep 2017
Laumonerie P Reina N Ancelin D Delclaux S Tibbo ME Bonnevialle N Mansat P

Aims

Radial head arthroplasty (RHA) may be used in the treatment of non-reconstructable radial head fractures. The aim of this study was to evaluate the mid-term clinical and radiographic results of RHA.

Patients and Methods

Between 2002 and 2014, 77 RHAs were implanted in 54 men and 23 women with either acute injuries (54) or with traumatic sequelae (23) of a fracture of the radial head. Four designs of RHA were used, including the Guepar (Small Bone Innovations (SBi)/Stryker; 36), Evolutive (Aston Medical; 24), rHead RECON (SBi/Stryker; ten) or rHead STANDARD (SBi/Stryker; 7) prostheses. The mean follow-up was 74.0 months (standard deviation (sd) 38.6; 24 to 141). The indication for further surgery, range of movement, mean Mayo Elbow Performance (MEP) score, quick Disabilities of the Arm, Shoulder and Hand (quickDASH) score, osteolysis and positioning of the implant were also assessed according to the design, and acute or delayed use.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 520 - 526
1 Apr 2015
Roberts SB Beattie N McNiven ND Robinson CM

The natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients remains unclear and there is no consensus for management of these patients.

The objectives of this study were to report the natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients and to identify the risk factors for recurrent dislocation.

We reviewed prospectively-collected clinical and radiological data on 133 adolescent patients diagnosed with a primary anterior dislocation of the glenohumeral joint who had been managed non-operatively at our hospital between 1996 and 2008. There were 115 male (86.5%) and 18 female patients (13.5%) with a mean age of 16.3 years (13 to 18) and a mean follow-up of 95.2 months (1 to 215).

During follow-up, 102 (absolute incidence of 76.7%) patients had a recurrent dislocation. The median interval between primary and recurrent dislocation was ten months (95% CI 7.4 to 12.6). Applying survival analysis the likelihood of having a stable shoulder one year after the initial injury was 59% (95% CI 51.2 to 66.8), 38% (95% CI 30.2 to 45.8%) after two years, 21% (95% CI 13.2 to 28.8) after five years, and 7% (95% CI 1.1 to 12.9) after ten years. Neither age nor gender significantly predicted recurrent dislocation during follow-up.

We conclude that adolescent patients with a primary anterior dislocation of the glenohumeral joint have a high rate of recurrent dislocation, which usually occurs within two years of their initial injury: these patients should be considered for early operative stabilisation.

Cite this article: Bone Joint J 2015;97-B:520–6.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 812 - 817
1 Jun 2017
Woods DA Loganathan K

Aims

Manipulation under anaesthetic (MUA) is a recognised form of treatment for patients with a frozen shoulder. However, not all patients benefit. Some have persistent or recurrent symptoms. There are no clear recommendations in the literature on the optimal management of recurrent frozen shoulder after a MUA. We aimed to address this issue in this study.

Patients and Methods

We analysed a prospectively collected, single-surgeon, consecutive series of patients who underwent MUA for frozen shoulder between January 1999 and December 2015. The Oxford Shoulder Scores (OSS) and range of movement were the outcome measures.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims

We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA).

Materials and Methods

We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203).


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 209 - 217
1 Feb 2016
Satbhai NG Doi K Hattori Y Sakamoto S

Aims

Between 2002 and 2011, 81 patients with a traumatic total brachial plexus injury underwent reconstruction by double free muscle transfer (DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve transfers (NT, 18 cases).

Methods

They were evaluated for functional outcome and quality of life (QoL) using the Disability of Arm, Shoulder and Hand questionnaire, both pre- and post-operatively. The three groups were compared and followed-up for at least 24 months.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 963 - 966
1 Jul 2015
Evans JP Guyver PM Smith CD

Frozen shoulder is a recognised complication following simple arthroscopic shoulder procedures, but its exact incidence has not been reported. Our aim was to analyse a single-surgeon series of patients undergoing arthroscopic subacromial decompression (ASD; group 1) or ASD in combination with arthroscopic acromioclavicular joint (ACJ) excision (group 2), to establish the incidence of frozen shoulder post-operatively. Our secondary aim was to identify associated risk factors and to compare this cohort with a group of patients with primary frozen shoulder.

We undertook a retrospective analysis of 200 consecutive procedures performed between August 2011 and November 2013. Group 1 included 96 procedures and group 2 104 procedures. Frozen shoulder was diagnosed post-operatively using the British Elbow and Shoulder Society criteria. A comparative group from the same institution involved 136 patients undergoing arthroscopic capsular release for primary idiopathic frozen shoulder.

The incidence of frozen shoulder was 5.21% in group 1 and 5.71% in group 2. Age between 46 and 60 years (p = 0.002) and a previous idiopathic contralateral frozen shoulder (p < 0.001) were statistically significant risk factors for the development of secondary frozen shoulder. Comparison of baseline characteristics against the comparator groups showed no statistically significant differences for age, gender, diabetes and previous contralateral frozen shoulder.

These results suggest that the risk of frozen shoulder following simple arthroscopic procedures is just over 5%, with no increased risk if the ACJ is also excised. Patients aged between 46 and 60 years and a previous history of frozen shoulder increase the relative risk of secondary frozen shoulder by 7.8 (95% confidence interval (CI) 2.1 to 28.3)and 18.5 (95% CI 7.4 to 46.3) respectively.

Cite this article: Bone Joint J 2015; 97-B:963–6.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1208 - 1214
1 Sep 2016
Cowling PD Akhtar MA Liow RYL

Objectives

A variety of operative techniques have been described as under the term ‘Bristow-Latarjet’ procedure. This review aims to define the original procedure, and compare the variation in techniques described in the literature, assessing any effect on clinical outcomes.

Materials and Methods

A systematic review of 24 studies was performed to compare specific steps of the technique (coracoid osteotomy site, subscapularis approach, orientation and position of coracoid graft fixation and fixation method, additional labral and capsular repair) and detect any effect this variability had on outcomes.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims

Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA.

Patients and Methods

Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three.

Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89).


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 969 - 975
1 Jul 2016
Theivendran K Varghese M Large R Bateman M Morgan M Tambe A Espag M Cresswell T Clark DI

Aim

We present the medium-term clinical results of a reverse total shoulder arthroplasty with a trabecular metal glenoid base plate.

Patients and Methods

We reviewed 125 consecutive primary reverse total shoulder arthroplasties (RTSA) implanted in 124 patients for rotator cuff arthropathy. There were 100 women and 24 men in the study group with a mean age of 76 years (58 to 89). The mean follow-up was 32 months (24 to 60). No patient was lost to follow-up.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 512 - 518
1 Apr 2016
Spencer HT Hsu L Sodl J Arianjam A Yian EH

Aims

To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries.

Patients and Methods

We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1239 - 1243
1 Sep 2014
Zafra M Uceda P Flores M Carpintero P

Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia’s classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection.

Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high.

Cite this article: Bone Joint J 2014;96-B:1239–43.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 75 - 80
1 Jan 2016
Merolla G Chin P Sasyniuk TM Paladini P Porcellini G

Aims

We evaluated clinical and radiographic outcomes of total shoulder arthroplasty (TSA) using the second-generation Trabecular Metal (TM) Glenoid component. The first generation component was withdrawn in 2005 after a series of failures were reported. Between 2009 and 2012, 40 consecutive patients with unilateral TSA using the second-generation component were enrolled in this clinical study. The mean age of the patients was 63.8 years (40 to 75) and the mean follow-up was 38 months (24 to 42).

Methods

Patients were evaluated using the Constant score (CS), the American Shoulder and Elbow Surgeons (ASES) score and routine radiographs.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1377 - 1384
1 Oct 2015
Nestorson J Ekholm C Etzner M Adolfsson L

We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients.

A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation.

The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients.

Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty.

Cite this article: Bone Joint J 2015;97-B:1377–84.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach.

We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis.

Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps.

Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (sd) 5.5), 0.3° valgus (sd 2.7), and 0.7° extension (sd 3.2) for the humeral component, and 9.3° pronation (sd 9.7), 0.3° valgus (sd 4.0), and 8.6° extension (sd 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs.

The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results.

Cite this article: 2015;97-B:1096–1101.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 967 - 972
1 Jul 2015
Hussey MM Hussey SE Mighell MA

Failed internal fixation of a fracture of the proximal humerus produces many challenges with limited surgical options. The aim of this study was to evaluate the clinical outcomes after the use of a reverse shoulder arthroplasty under these circumstances. Between 2007 and 2012, 19 patients (15 women and four men, mean age 66 years; 52 to 82) with failed internal fixation after a proximal humeral fracture, underwent implant removal and reverse shoulder arthroplasty (RSA). The mean follow-up was 36 months (25 to 60). The mean American Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019). The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p = 0.020), and the mean visual analogue scale for pain improved from 6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7° to 101.1° (p < 0.001), mean abduction from 58.7° to 89.1° (p = 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043) and mean internal rotation from buttocks to L4 (p = 0.034). A major complication was recorded in five patients (26%) (one intra-operative fracture, loosening of the humeral component in two and two peri-prosthetic fractures). A total of 15 patients (79%) rated their outcome as excellent or good, one (5%) as satisfactory, and three (16%) as unsatisfactory.

An improvement in outcomes and pain can be expected when performing a RSA as a salvage procedure after failed internal fixation of a fracture of the proximal humerus. Patients should be cautioned about the possibility for major complications following this technically demanding procedure.

Cite this article: Bone Joint J 2015;97-B:967–72.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1681 - 1687
1 Dec 2014
Foruria AM Lawrence TM Augustin S Morrey BF Sanchez-Sotelo J

We retrospectively reviewed 89 consecutive patients (45 men and 44 women) with a mean age at the time of injury of 58 years (18 to 97) who had undergone external fixation after sustaining a unilateral fracture of the distal humerus. Our objectives were to determine the incidence of heterotopic ossification (HO); identify risk factors associated with the development of HO; and characterise the location, severity and resultant functional impairment attributable to the presence of HO.

HO was identified in 37 elbows (42%), mostly around the humerus and along the course of the medial collateral ligament. HO was hazy immature in five elbows (13.5%), mature discrete in 20 (54%), extensive mature in 10 (27%), and complete bone bridges were present in two elbows (5.5%). Mild functional impairment occurred in eight patients, moderate in 27 and severe in two. HO was associated with less extension (p = 0.032) and less overall flexion-to-extension movement (p = 0.022); the flexion-to-extension arc was < 100º in 21 elbows (57%) with HO compared with 18 elbows (35%) without HO (p = 0.03). HO was removed surgically in seven elbows.

The development of HO was significantly associated with sustaining a head injury (p = 0.015), delayed internal fixation (p = 0.027), the method of fracture fixation (p = 0.039) and the use of bone graft or substitute (p = 0.02).HO continues to be a substantial complication after internal fixation for distal humerus fractures.

Cite this article: Bone Joint J 2014;96-B:1681–7.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 117 - 122
1 Apr 2014
Uhthoff HK Coletta E Trudel G

Objectives

Although many clinical and experimental investigations have shed light on muscle atrophy and intramuscular accumulation of fat after rotator cuff disruption, none have reported on their onset in the absence of muscle retraction.

Methods

In 30 rabbits, we detached one supraspinatus (SSP) tendon and repaired it immediately, thus preventing muscle retraction. The animals were killed in groups of 10 at one, two and six weeks. Both shoulders of 15 non-operated rabbits served as controls. We measured the weight and volume of SSP muscles and quantified the cross-sectional area of intramuscular fat (i-fat) histologically.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 354 - 359
1 Mar 2014
Khan A Samba A Pereira B Canavese F

The ideal treatment for traumatic anterior dislocation of the shoulder in the skeletally immature patient is controversial. The aim of this study is to evaluate the outcomes after either conservative and/or surgical treatment using the Latarjet technique. A retrospective series of 49 out of 80 patients were reviewed. We found no significant differences between either treatment method regarding functional scores and pain levels. Although not statistically significant, post-surgical patients showed better signs of shoulder stability than others who have a higher rate of recurrence. Further, 92% of the post-surgical group had returned to the same level of activity versus 52% in the non-surgically treated group. We found no contraindications to operate on a skeletally immature patient.

Cite this article: Bone Joint J 2014;96-B:354–9.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 35 - 35
1 Aug 2013
Tytherleigh-Strong G


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 224 - 228
1 Feb 2014
Simone JP Streubel PH Athwal GS Sperling JW Schleck CD Cofield RH

We assessed the clinical results, radiographic outcomes and complications of patients undergoing total shoulder replacement (TSR) for osteoarthritis with concurrent repair of a full-thickness rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%) undergoing TSR for osteoarthritis underwent rotator cuff repair. The final study group comprised 33 patients with a mean follow-up of 4.7 years (3 months to 13 years). Tears were classified into small (10), medium (14), large (9) or massive (0). On a scale of 1 to 5, pain decreased from a mean of 4.7 to 1.7 (p = < 0.0001), the mean forward elevation improved from 99° to 139° (p = < 0.0001), and the mean external rotation improved from 20° (0° to 75°) to 49° (20° to 80°) (p = < 0.0001). The improvement in elevation was greater in those with a small tear (p = 0.03). Radiographic evidence of instability developed in six patients with medium or large tears, indicating lack of rotator cuff healing. In all, six glenoid components, including one with instability, were radiologically at risk of loosening. Complications were noted in five patients, all with medium or large tears; four of these had symptomatic instability and one sustained a late peri-prosthetic fracture. Four patients (12%) required further surgery, three with instability and one with a peri-prosthetic humeral fracture.

Consideration should be given to performing rotator cuff repair for stable shoulders during anatomical TSR, but reverse replacement should be considered for older, less active patients with larger tears.

Cite this article: Bone Joint J 2014;96-B:224–8.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 229 - 236
1 Feb 2014
deVos MJ Verdonschot N Luites JWH Anderson PG Eygendaal D

We determined the short-term clinical outcome and migration within the bone of the humeral cementless component of the Instrumented Bone Preserving (IBP) total elbow replacement in a series of 16 patients. There were four men and 12 women with a mean age at operation of 63 years (40 to 81). Migration was calculated using radiostereometric analysis. There were no intra-operative complications and no revisions. At two-year follow-up, all patients showed a significant reduction in pain and functional improvement of the elbow (both p < 0.001). Although ten components (63%) showed movement or micromovement during the first six weeks, 14 (88%) were stable at one year post-operatively. Translation was primarily found in the proximal direction (median 0.3 mm (interquartile range (IQR) -0.09 to 0.8); the major rotational movement was an anterior tilt (median 0.7° (IQR 0.4° to 1.6°)). One malaligned component continued to migrate during the second year, and one component could not be followed beyond three months because migration had caused the markers to break off the prosthesis.

This study shows promising early results for the cementless humeral component of the IBP total elbow replacement. All patients had a good clinical outcome, and most components stabilised within six months of the operation.

Cite this article: Bone Joint J 2014;96-B:229–36.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1106 - 1113
1 Aug 2013
Lädermann A Walch G Denard PJ Collin P Sirveaux F Favard L Edwards TB Kherad O Boileau P

The indications for reverse shoulder arthroplasty (RSA) continue to be expanded. Associated impairment of the deltoid muscle has been considered a contraindication to its use, as function of the RSA depends on the deltoid and impairment of the deltoid may increase the risk of dislocation. The aim of this retrospective study was to determine the functional outcome and risk of dislocation following the use of an RSA in patients with impaired deltoid function. Between 1999 and 2010, 49 patients (49 shoulders) with impairment of the deltoid underwent RSA and were reviewed at a mean of 38 months (12 to 142) post-operatively. There were nine post-operative complications (18%), including two dislocations. The mean forward elevation improved from 50° (sd 38; 0° to 150°) pre-operatively to 121° (sd 40; 0° to 170°) at final follow-up (p < 0.001). The mean Constant score improved from 24 (sd 12; 2 to 51) to 58 (sd 17; 16 to 83) (p < 0.001). The mean Single Assessment Numeric Evaluation score was 71 (sd 17; 10 to 95) and the rate of patient satisfaction was 98% (48 of 49) at final follow-up.

These results suggest that pre-operative deltoid impairment, in certain circumstances, is not an absolute contraindication to RSA. This form of treatment can yield reliable improvement in function without excessive risk of post-operative dislocation.

Cite this article: Bone Joint J 2013;95-B:1106–13.