The aim of this study was to determine the current incidence and epidemiology of humeral diaphyseal fractures. The secondary aim was to explore variation in patient and injury characteristics by fracture location within the humeral diaphysis. Over ten years (2008 to 2017), all adult patients (aged ≥ 16 years) sustaining an acute fracture of the humeral diaphysis managed at the study centre were retrospectively identified from a trauma database. Patient age, sex, medical/social background, injury mechanism, fracture classification, and associated injuries were recorded and analyzed.Aims
Methods
Aims. Fractures of the humeral
Aims. Though most humeral
Aims. The primary aim was to estimate the cost-effectiveness of routine operative fixation for all patients with humeral
Aims. The aims of this study were to describe the epidemiology of metacarpal
Aims. The aim of this study was to assess the safety and clinical outcome of patients with a femoral
Aims. The primary aim of this study was to determine the rates of return to work (RTW) and sport (RTS) following a humeral
Aims. To compare results of institutional preferences with regard to treatment of soft tissues in the setting of open tibial
Aims. The primary aim of this study was to develop a reliable, effective radiological score to assess the healing of humeral
Aims. The aim of this study was to describe the epidemiology of closed
isolated fractures of the femoral
Objectives. Experimental studies indicate that non-steroidal anti-inflammatory drugs (NSAIDs) may have negative effects on fracture healing. This study aimed to assess the effect of immediate and delayed short-term administration of clinically relevant parecoxib doses and timing on fracture healing using an established animal fracture model. Methods. A standardized closed tibia
We studied the epidemiology of 401 fractures of the
The management of radial nerve palsy associated with fractures of the
Methods. Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral
We report on the use of the Ilizarov method to
treat 40 consecutive fractures of the tibial
1. It appears that fracture of the humeral
1. Previous investigations into the blood supply of the femoral
Objectives. Healing in cancellous metaphyseal bone might be different from
midshaft fracture healing due to different access to mesenchymal
stem cells, and because metaphyseal bone often heals without a cartilaginous
phase. Inflammation plays an important role in the healing of a
shaft fracture, but if metaphyseal injury is different, it is important
to clarify if the role of inflammation is also different. The biology
of fracture healing is also influenced by the degree of mechanical
stability. It is unclear if inflammation interacts with stability-related
factors. Methods. We investigated the role of inflammation in three different models:
a metaphyseal screw pull-out, a
We analysed retrospectively the risk factors
leading to femoral overgrowth after flexible intramedullary nailing
in 43 children (mean age 7.1 years (3.6 to 12.0)) with fractures
of the
1. The results of treatment of fractures of the
We report retrospective and prospective studies to identify the causes of fracture of the femoral neck associated with femoral
Ninety-eight fractures of the
Fractures of the femoral
We have analysed the initial displacement and the retention of position after reduction of 192 spiral fractures of the tibial
1. The combination of femoral
Hindfoot (subtalar) movement and disability after fracture of the tibial
Twenty-six children conservatively treated for fracture of the femoral
A study was made of the mechanics of blood-bearing in a series of patients treated with a cast-brace for fracture of the distal femur. Knee hinges incorporating strain-gauges, a simple force-plate on the floor and a standardised weight-bearing test were used to record axial loads through the cast-brace itself and through the fracture during the phases of healing. The cast-brace carried loads of only 10 to 20 per cent of body weight and functioned mainly as an antibuckling hinged tube. Patterns of weight-bearing recovery showed that the fracture itself limited loads to safe levels. A measure of the recovery of strength at the fracture was determined and termed the "fracture load index". Graphs obtained in this way demonstrated four biomechanical phases of bony union which correlated well with the stages of clinical healing. The clinical application of these results have led to improvements in the design of braces and the use of a cylinder cast-brace for fractures of the distal half of the femoral
1. The frequency of variable degrees of ischaemia of soft tissue in closed tibial and fibular
Intramedullary locking nails have proved to be of considerable advantage when treating complex, comminuted or segmental femoral
The treatment of fractures of the femoral
From a series of 190 consecutive fractures of the
1. The results in 211 fractures of the
1. A series of twenty-one cases of re-fracture of the femoral
We reviewed 28 children with unilateral middle-third fractures of the femoral
Ten uncemented total hip replacements were performed in 1975 using an implant in which the cobalt-chrome femoral stem was coated to give a porous surface. In all but one case a high-density polyethylene head was used. The radiological changes in the upper femoral
We randomised prospectively 44 patients with fractures of the
One hundred patients who had sustained a fracture of the tibial
1. A series of 154 patients with 156 femoral
The management of closed fractures of the humerus with an associated nerve palsy remains controversial. With very little written about this injury in children, we present the case of a three-year-old child with a closed humeral
We undertook a retrospective study of 50 consecutive patients (41 male, 9 female) with an infected nonunion and bone defect of the femoral
We treated 39 patients with fractures of the humeral
We have analysed 249 consecutive fractures of the humeral
We performed a prospective randomised trial on matched groups of patients with displaced tibial
One hundred consecutive closed fractures of the adult tibial
We report the outcome of 19 children aged 5.2 to 13.2 years with 20 fractures of the femoral
1. One hundred and eighty-one fractures of the tibial
1. A method of medullary nailing of fractures of the
Excellent results can be achieved by plating fractures of the
1. A study of the late results of 343 soundly united tibial
We analysed the results of 93 tibial
We have used total hip replacement combined with cemented intramedullary nailing to treat a selected group of nine patients with pathological fractures of the proximal femur and impending fractures of the
1 . A series of 343 tibial
In patients with traumatic brain injury and fractures
of long bones, it is often clinically observed that the rate of bone
healing and extent of callus formation are increased. However, the
evidence has been unconvincing and an association between such an
injury and enhanced fracture healing remains unclear. We performed
a retrospective cohort study of 74 young adult patients with a mean
age of 24.2 years (16 to 40) who sustained a femoral
The torsion of both femora was evaluated in 110 patients who had been treated by intramedullary nailing for unilateral femoral
1. Three cases of injury to the femoro-popliteal artery complicating fracture of the femoral
We report the use of elastic stable intramedullary nailing (ESIN) in 123 fractures of the femoral
All tibial
The off-loading characteristics of the cast-braces of 30 patients with fractures of the
In two hospitals, 115 consecutive open femoral
1. Eighty consecutive open fractures of the tibial
The Medoff sliding plate (MSP) is a new device used to treat intertrochanteric and subtrochanteric fractures. There are three options for sliding; either along the
We studied 47 patients with closed, displaced, diaphyseal fractures of the femur caused by blunt trauma, to determine the incidence of associated knee injuries, particularly of the meniscus. After femoral nailing, all patients had an examination under anaesthesia and an arthroscopy. There were 12 medial meniscal injuries (5 tears) and 13 injuries of the lateral meniscus (8 tears). Ten of the 13 tears were in the posterior third of the meniscus, and two patients had tears of both menisci. Synovitis was common at the meniscal attachments. Complex and radial tears were more common than peripheral or bucket-handle tears. Examination under anaesthesia revealed ligamentous laxity in 23 patients (49%), but meniscal injuries had a similar incidence in knees with and without ligament injury. Femoral
We have treated 42 consecutive complex ununited fractures of the femoral
We describe the use of intramedullary reconstruction nails in the treatment of 14 patients with pathological subtrochanteric fractures and coexisting metastases in the femoral
We describe the use of Ender nails for the internal fixation of femoral
Ten patients with humeral
We measured pressures in the anterior and deep posterior compartments continuously for up to 72 hours in 20 patients with closed fractures of the tibial
The stability of union following the conservative treatment of tibial
Sixty patients each of whom had a fracture of the lower limb a minimum of five years (median 11 years) previously were studied by photoplethysmography, foot volumetry, popliteal venous reflux and arterial Doppler measurements. The non-fractured limb was used as a control. Postphlebitic symptoms were present in 51% and signs in 49% of fractured limbs compared with 4% and 24% respectively in the control limbs. The incidence was greater in patients who had fractured 15 years or more previously than in those who had fractured 5 to 15 years previously. Eleven limbs had clinically disabling postphlebitic symptoms including venous ulceration. The postphlebitic syndrome following lower limb fractures in young patients is more common than generally appreciated and develops after a prolonged latent interval. A prospective randomised study using prophylactic anticoagulation for lower limb
In a prospective study, we randomly allocated 39 patients with isolated fractures of the lower two-thirds of the ulnar
A prospective study of 141 patients with 143 tibial
We have reviewed 402 traumatic fractures of the femoral
We have reviewed our recent results with functional bracing of tibial
We reviewed and radiographed 30 skeletally-mature patients after isolated closed femoral
One hundred and two fractures of the femoral
Over 15 years (1967 to 1982) 140 uncomplicated femoral
We report our experience with a modified implant and a new technique for locked intramedullary nailing of the humerus in 41 patients. Locking was by cross-screws placed from lateral to medial in the proximal humerus, and anteroposteriorly in the distal humerus. Early in the series, 11 nails were inserted at the shoulder, but we found that rehabilitation was faster after retrograde nailing through the olecranon fossa, which was used for the other 30. We used a closed technique for 29 of the nailings. Of the 41 patients treated, 21 had acute fractures, five had nonunion, and 15 had pathological fractures. Secure fixation was obtained for comminuted and osteoporotic fractures in any part of the humeral
The use of two implants to manage concomitant ipsilateral femoral
shaft and proximal femoral fractures has been indicated, but no
studies address the relationship of dynamic hip screw (DHS) side
plate screws and the intramedullary nail where failure might occur
after union. This study compares different implant configurations
in order to investigate bridging the gap between the distal DHS
and tip of the intramedullary nail. A total of 29 left synthetic femora were tested in three groups:
1) gapped short nail (GSN); 2) unicortical short nail (USN), differing
from GSN by the use of two unicortical bridging screws; and 3) bicortical
long nail (BLN), with two angled bicortical and one unicortical bridging
screws. With these findings, five matched-pairs of cadaveric femora
were tested in two groups: 1) unicortical long nail (ULN), with
a longer nail than USN and three bridging unicortical screws; and
2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally
rotated 90°/sec until failure.Objectives
Methods
1. A series of 705 fractures of the tibia is reviewed, 674 of which were treated conservatively. 2. The factors most conducive to delayed or non-union are initial displacement, comminution, associated soft-tissue wound and infection. The extent to which these are combined in any fracture determines its "personality" and its inherent propensity for union. 3. Eight fracture types are differentiated based on the above "personality rating." The incidence of delayed union or non-union varies from 9 per cent in the most favourable type to 39 per cent in the least favourable. Infection raises the incidence to 60 per cent. Comparative statistics which fail to recognise these differences can be entirely misleading. 4. Continuous traction does not retard union. 5. The results of conservative treatment are analysed with regard to union, deformity, stiff joints and contractures and the conclusion is reached that no case has yet been made out for internal fixation as the method of choice in the treatment of this fracture.
We have systematically reviewed the effect of alternative methods of stabilisation of open tibial fractures on the rates of reoperation, and the secondary outcomes of nonunion, deep and superficial infection, failure of the implant and malunion by the analysis of 799 citations on the subject, identified from computerised databases. Although 68 proved to be potentially eligible, only eight met all criteria for inclusion. Three investigators independently graded the quality of each study and extracted the relevant data. One study (n = 56 patients) suggested that the use of external fixators significantly decreased the requirement for reoperation when compared with fixation with plates. The use of unreamed nails, compared with external fixators (five studies, n = 396 patients), reduced the risk of reoperation, malunion and superficial infection. Comparison of reamed with unreamed nails showed a reduced risk of reoperation (two studies, n = 132) with the reamed technique. An indirect comparison between reamed nails and external fixators also showed a reduced risk of reoperation (two studies) when using nails. We have identified compelling evidence that unreamed nails reduced the incidence of reoperations, superficial infections and malunions, when compared with external fixators. The relative merits of reamed
It is accepted that resurfacing hip replacement
preserves the bone mineral density (BMD) of the femur better than total
hip replacement (THR). However, no studies have investigated any
possible difference on the acetabular side. Between April 2007 and March 2009, 39 patients were randomised
into two groups to receive either a resurfacing or a THR and were
followed for two years. One patient’s resurfacing subsequently failed,
leaving 19 patients in each group. Resurfaced replacements maintained proximal femoral BMD and,
compared with THR, had an increased bone mineral density in Gruen
zones 2, 3, 6, and particularly zone 7, with a gain of 7.5% (95%
confidence interval (CI) 2.6 to 12.5) compared with a loss of 14.6%
(95% CI 7.6 to 21.6). Resurfacing replacements maintained the BMD
of the medial femoral neck and increased that in the lateral zones
between 12.8% (95% CI 4.3 to 21.4) and 25.9% (95% CI 7.1 to 44.6). On the acetabular side, BMD was similar in every zone at each
point in time. The mean BMD of all acetabular regions in the resurfaced
group was reduced to 96.2% (95% CI 93.7 to 98.6) and for the total
hip replacement group to 97.6% (95% CI 93.7 to 101.5) (p = 0.4863).
A mean total loss of 3.7% (95% CI 1.0 to 6.5) and 4.9% (95% CI 0.8
to 9.0) of BMD was found above the acetabular component in W1 and
10.2% (95% CI 0.9 to 19.4) and 9.1% (95% CI 3.8 to 14.4) medial
to the implant in W2 for resurfaced replacements and THRs respectively.
Resurfacing resulted in a mean loss of BMD of 6.7% (95% CI 0.7 to
12.7) in W3 but the BMD inferior to the acetabular component was
maintained in both groups. These results suggest that the ability of a resurfacing hip replacement
to preserve BMD only applies to the femoral side.
A protocol for the treatment of fractures of the middle third of the femur by the early application of a hip spica has been evaluated in 191 children aged 10 years or less. Children without other injuries spent only a few days in hospital for the application and later removal of the spica. At all ages, anterior angulation of less than 20 degrees and valgus angulation of less than 15 degrees were accepted at the one-week review. Acceptance of shortening varied with the age of the child and the stage of treatment, but was 10% or less of the femoral length at the time of spica removal. At late review leg-length discrepancy was rare and clinically insignificant. This method of treatment was simple and effective. It dramatically reduced the cost of care and freed a number of children's hospital beds.
1. The probable greatest bending moment applied to a plated or nailed fracture of the tibia during restricted weight-bearing is estimated to be, in men, up to about 79 Newton metres (58 poundsforce feet). The maximum twisting moment is estimated to be about 29 Newton metres (22 poundsforce feet). 2. Twenty-two human tibiae were loaded in three-point bending and broke at bending moments of from 57·9 to 294 Newton metres (42·7 to 216 poundsforce feet) if they had not previously been drilled; tibiae which had holes made through both cortices with a c. 3-millimetre (⅛-inch) drill broke at from 32·4 to 144 Newton metres (23·8 to 106 poundsforce feet). Tibiae loaded in torsion broke at twisting moments of from 27·5 to 892 Newton metres (20·2 to 65·8 poundsforce feet) when not drilled, 23·6 to 77·5 Newton metres (l7·3 to 57·1 poundsforce feet) when drilled. 3. When bent so as to open the fracture site, the 14-centimetre Stamm was the strongest of all the single plates tested (reaching its elastic limit at a bending moment of 17·6 Newton metres (13 poundsforce feet) and 5 degrees total angulation at 22·6 Newton metres (16·6 poundsforce feet)), while the Venable was the weakest (elastic limit 4·9 Newton metres (3·6 poundsforce feet) and 5 degrees at 7·9 Newton metres (5·8 poundsforce feet)). A 13-millimetre Küntscher nail reached its elastic limit at 42·2 Newton metres (31·1 poundsforce feet) and 5 degrees total angulation at 49 Newton metres (36 poundsforce feet). 4. In torsion the 15-centimetre Hicks was the strongest ofthe plates (elastic limit 27·5 Newton metres (20·2 poundsforce feet) and 5 degrees rotation at 16·7 Newton metres (l2·3 poundsforce feet)). 5. Küntscher nails in bones provided no dependable strength in torsion. 6. In both bending and torsion, a preparation of one Venable plate on each of the two anterior surfaces was stronger than any single plate, and was as strong as the weaker drilled tibiae. 7. The three currently available metallic materials (stainless steel, cobalt-chrome and titanium) have static mechanical properties so similar that the choice between them can be made on other grounds. 8. The highest load applied to a screw during bending tests was about half that needed to pull a screw out of even a thin-walled tibia. 9. Screws beyond four for one plate are mechanically redundant at the moment of implantation but may be necessary as an insurance against subsequent deterioration in strength. 10. Countersinks in plates are a source of significant weakness, and should preferably be as shallow as possible. 11. An unoccupied screw hole in the centre of a plate is a source of serious weakness. 12. Only the strongest implants tested were strong enough to withstand the bending or twisting moments to be expected in restricted weight-bearing. In two-plate preparations a danger is introduced by the fact that these moments are similar to those required to Ireak a drilled tibia.
1. A brief summary is given of the literature on patients with a dislocated hip and a fractured femur on the same side. 2. One further patient is reported, treated by closed reduction of the hip and the fracture. 3. A warning is given on the frequency with which the dislocation is not diagnosed in this double injury.
We have reviewed our experience of four iatrogenic femoral neck fractures in 315 consecutive closed intramedullary nailings with the AO/ASIF universal femoral nail. The average neck-shaft angle in the bones that fractured was 139.3 degrees +/- 1.2 degrees SD (136 to 141); in the whole series the average neck-shaft angle was 125.3 degrees +/- 8.6 degrees and only 11 had angles of more than 135 degrees. The upper ends of the nails in the four which fractured were 17 mm, 5 mm, 3 mm, and 1 mm below the tip of the greater trochanter. In the seven patients with neck-shaft angles greater than 135 degrees but with no fracture, none of the nails had been inserted beyond the tip of the greater trochanter. We nailed six cadaver femora to simulate the forces produced by intramedullary nailing. Despite deep insertion, only one of the six sustained a neck fracture. This specimen had a radiographic neck-shaft angle of 140 degrees against an average of 127.3 degrees +/- 4.0 degrees for the other five. We believe that the medial prong of the AO insertion jig, with its medial overhang of 2 to 3 mm, may impinge on the superior aspect of a valgus femoral neck during final impaction, causing a neck fracture. This may be avoided by leaving the end of the nail above the tip of the trochanter in such cases.