Advertisement for orthosearch.org.uk
Results 1 - 100 of 454
Results per page:
Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims. The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with ‘any cause revision’ was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion. In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%. Cite this article: Bone Jt Open 2023;4(10):776–781


Aims. The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral. Methods. The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype. Results. The most common phenotype was Type I-b (mild to moderate varus alignment-medial joint line; 27.1% (n = 256)), followed by Type IV-b (23.2%; n = 219). There was no significant difference in the clinical outcomes and long-term survival between the groups. In Type IV-b phenotypes, the neutrally corrected group showed higher 15-year survival compared with the unchanged-phenotype group (94.9% (95% confidence interval (CI) 92.0 to 97.8) vs 74.2% (95% CI 98.0 to 100); p = 0.020). Conclusion. Constitutional varus was confirmed in more than half of these patients. Mechanically aligned TKA can achieve consistent clinical outcomes and long-term survival, regardless of the patient’s phenotype. The neutrally corrected group had better long-term survival compared with the unchanged phenotype group. Cite this article: Bone Joint J 2024;106-B(5):460–467


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 875 - 883
1 Jul 2022
Mills K Wymenga AB van Hellemondt GG Heesterbeek PJC

Aims. Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). Methods. This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). Results. The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. Conclusion. These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875–883


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 840 - 845
1 May 2021
Rossi SMP Perticarini L Clocchiatti S Ghiara M Benazzo F

Aims. In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. Methods. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis. Results. The mean follow-up was nine years (6 to 13). All scores significantly improved from preoperatively to final follow-up (mean and SD): OKS from 23.2 (8.1) to 42.5 (3.5), EQ-5D from 0.44 (0.25) to 0.815 (0.1), EQ-VAS from 46.7 (24.9) to 89.1 (9.8), KSS (Knee) from 51.4 (8.5) to 94.4 (4.2), and KSS (Function) from 48.7 (5.5) to 88.8 (5.2). The mean FJS at final follow-up was 79.2 (4.2). All failures involved the medial UKA + PFA group. Overall, survival rate was 91.5% for all the combined implants at ten years with 95% confidence intervals and 22 knees at risk. Conclusion. Excellent clinical and radiological outcomes were achieved after a third-generation PFA combined with a medial or lateral UKA. BCA with unlinked partial knee prostheses showed a good survival rate at mid- to long-term follow-up. Cite this article: Bone Joint J 2021;103-B(5):840–845


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 55 - 60
1 Jul 2019
Laende EK Richardson CG Dunbar MJ

Aims. Early implant migration measured with radiostereometric analysis (RSA) has been proposed as a useful predictor of long-term fixation of tibial components in total knee arthroplasty. Evaluation of actual long-term fixation is of interest for cemented components, as well as for cementless fixation, which may offer long-term advantages once osseointegration has occurred. The objective of this study was to compare the long-term migration with one- and two-year migration to evaluate the predictive ability of short-term migration data and to compare migration and inducible displacement between cemented and cementless (porous metal monoblock) components at least ten years postoperatively. Patients and Methods. Patients who had participated in RSA migration studies with two-year follow-up were recruited to return for a long-term follow-up, at least ten years from surgery. Two cemented tibial designs from two manufacturers and one porous metal monoblock cementless tibial design were studied. At the long-term follow-up, patients had supine RSA examinations to determine migration and loaded examinations (single leg stance) to determine inducible displacement. In total, 79 patients (54 female) returned, with mean time since surgery of 12 years (10 to 14). There were 58 cemented and 21 cementless tibial components. Results. Migration at one year and two years was significantly correlated with long-term migration (p < 0.001). Median migration at the long-term follow-up was 0.6 mm (maximum total point motion; interquartile range (IQR) 0.4 to 0.9) for the cemented group and 0.6 mm. (IQR 0.3 to 1.1) for the cementless group with no difference between groups (p = 0.99). Inducible displacement was significantly lower for the cementless components (p < 0.001). Conclusion. Long-term migration was strongly correlated with two-year migration. Although long-term migration was not different for cemented or cementless tibial components, inducible displacement at the long-term visit was significantly lower for these cementless components, suggesting superior fixation. These findings support the predictive value of short-term migration in determining long-term fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):55–60


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 45 - 52
1 Jan 2022
Yapp LZ Clement ND Moran M Clarke JV Simpson AHRW Scott CEH

Aims. The aim of this study was to determine the long-term mortality rate, and to identify factors associated with this, following primary and revision knee arthroplasty (KA). Methods. Data from the Scottish Arthroplasty Project (1998 to 2019) were retrospectively analyzed. Patient mortality data were linked from the National Records of Scotland. Analyses were performed separately for the primary and revised KA cohorts. The standardized mortality ratio (SMR) with 95% confidence intervals (CIs) was calculated for the population at risk. Multivariable Cox proportional hazards were used to identify predictors and estimate relative mortality risks. Results. At a median 7.4 years (interquartile range (IQR) 4.0 to 11.6) follow-up, 27.8% of primary (n = 27,474/98,778) and 31.3% of revision (n = 2,611/8,343) KA patients had died. Both primary and revision cohorts had lower mortality rates than the general population (SMR 0.74 (95% CI 0.73 to 0.74); p < 0.001; SMR 0.83 (95% CI 0.80 to 0.86); p < 0.001, respectively), which persisted for 12 and eighteight years after surgery, respectively. Factors associated with increased risk of mortality after primary KA included male sex (hazard ratio (HR) 1.40 (95% CI 1.36 to 1.45)), increasing socioeconomic deprivation (HR 1.43 (95% CI 1.36 to 1.50)), inflammatory polyarthropathy (HR 1.79 (95% CI 1.68 to 1.90)), greater number of comorbidities (HR 1.59 (95% CI 1.51 to 1.68)), and periprosthetic joint infection (PJI) requiring revision (HR 1.92 (95% CI 1.57 to 2.36)) when adjusting for age. Similarly, male sex (HR 1.36 (95% CI 1.24 to 1.49)), increasing socioeconomic deprivation (HR 1.31 (95% CI 1.12 to 1.52)), inflammatory polyarthropathy (HR 1.24 (95% CI 1.12 to 1.37)), greater number of comorbidities (HR 1.64 (95% CI 1.33 to 2.01)), and revision for PJI (HR 1.35 (95% 1.18 to 1.55)) were independently associated with an increased risk of mortality following revision KA when adjusting for age. Conclusion. The SMR of patients undergoing primary and revision KA was lower than that of the general population and remained so for several years post-surgery. However, approximately one in four patients undergoing primary and one in three patients undergoing revision KA died within tenten years of surgery. Several patient and surgical factors, including PJI, were associated with the risk of mortality within ten years of primary and revision surgery. Cite this article: Bone Joint J 2022;104-B(1):45–52


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 9 - 15
1 Oct 2015
Parratte S Ollivier M Lunebourg A Abdel MP Argenson J

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (ie, combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation. Cite this article: Bone Joint J 2015;97-B(10 Suppl A):9–15


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 845 - 851
1 Jul 2020
Goh GS Liow MHL Tay YWA Chen JY Xu S Pang H Tay DK Chia S Lo N Yeo S

Aims. While patients with psychological distress have poorer short-term outcomes after total knee arthroplasty (TKA), their longer-term function is unknown. We aimed to 1) assess the influence of preoperative mental health status on long-term functional outcomes, quality of life, and patient satisfaction; and 2) analyze the change in mental health after TKA, in a cohort of patients with no history of mental health disorder, with a minimum of ten years’ follow-up. Methods. Prospectively collected data of 122 patients undergoing primary unilateral TKA in 2006 were reviewed. Patients were assessed pre- and postoperatively at two and ten years using the Knee Society Knee Score (KSKS) and Function Score (KSFS); Oxford Knee Score (OKS); and the Mental (MCS) and Physical Component Summary (PCS) which were derived from the 36-Item Short-Form Health Survey questionnaire (SF-36). Patients were stratified into those with psychological distress (MCS < 50, n = 51) and those without (MCS ≥ 50, n = 71). Multiple regression was used to control for age, sex, BMI, Charlson Comorbidity Index (CCI), and baseline scores. The rate of expectation fulfilment and satisfaction was compared between patients with low and high MCS. Results. There was no difference in the mean KSKS, KSFS, OKS, and SF-36 PCS at two years or ten years after TKA. Equal proportions of patients in each group attained the minimal clinically important difference for each score. Psychologically distressed patients had a comparable rate of satisfaction (91.8% (47/51) vs 97.1% (69/71); p = 0.193) and fulfilment of expectations (89.8% vs 97.1%; p = 0.094). The proportion of distressed patients declined from 41.8% preoperatively to 29.8% at final follow-up (p = 0.021), and their mean SF-36 MCS improved by 10.4 points (p < 0.001). Conclusion. Patients with poor mental health undergoing TKA may experience long-term improvements in function and quality of life that are comparable to those experienced by their non-distressed counterparts. These patients also achieved a similar rate of satisfaction and expectation fulfilment. Undergoing TKA was associated with improvements in mental health in distressed patients, although this effect may be due to residual confounding. Cite this article: Bone Joint J 2020;102-B(7):845–851


Bone & Joint Open
Vol. 3, Issue 6 | Pages 470 - 474
7 Jun 2022
Baek J Lee SC Ryu S Kim J Nam CH

Aims

The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up.

Methods

From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 467 - 472
1 Apr 2014
Nakamura E Okamoto N Nishioka H Karasugi T Hirose J Mizuta H

We report the long-term outcome of 33 patients (37 knees) who underwent proximal tibial open-wedge osteotomy with hemicallotasis (HCO) for medial osteoarthritis of the knee between 1995 and 2000. Among these, 29 patients with unilateral HCO were enrolled and 19 were available for review at a mean of 14.2 years (10 to 15.7) post-operatively. For these 19 patients, the mean Hospital for Special Surgery knee score was 60 (57 to 62) pre-operatively and 85 (82 to 87) at final follow-up (p < 0.001; paired t-test). The femorotibial angle and tibial inclination angle (IA) were measured at short-term follow-up, one to four years post-operatively, and showed no significant subsequent changes. The clinical scores and radiological measurements showed little change over time. One patient required conversion to total knee replacement during this time. These results suggest that the coronal angle achieved at operation is maintained at long-term follow up after HCO without alteration of the IA, providing a good long-term clinical outcome. Cite this article: Bone Joint J 2014;96-B:467–72


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1071 - 1080
1 Sep 2019
Abram SGF Judge A Beard DJ Carr AJ Price AJ

Aims. The aim of this study was to determine the long-term risk of undergoing knee arthroplasty in a cohort of patients with meniscal tears who had undergone arthroscopic partial meniscectomy (APM). Patients and Methods. A retrospective national cohort of patients with a history of isolated APM was identified over a 20-year period. Patients with prior surgery to the same knee were excluded. The primary outcome was knee arthroplasty. Hazard ratios (HRs) were adjusted by patient age, sex, year of APM, Charlson comorbidity index, regional deprivation, rurality, and ethnicity. Risk of arthroplasty in the index knee was compared with the patient’s contralateral knee (with vs without a history of APM). A total of 834 393 patients were included (mean age 50 years; 37% female). Results. Of those with at least 15 years of follow-up, 13.49% (16 256/120 493; 95% confidence interval (CI) 13.30 to 13.69) underwent subsequent arthroplasty within this time. In women, 22.07% (95% CI 21.64 to 22.51) underwent arthroplasty within 15 years compared with 9.91% of men (95% CI 9.71 to 10.12), corresponding to a risk ratio (RR) of 2.23 (95% CI 2.16 to 2.29). Relative to the general population, patients with a history of APM were over ten times more likely (RR 10.27; 95% CI 10.07 to 10.47) to undergo arthroplasty rising to almost 40 times more likely (RR 39.62; 95% CI 27.68 to 56.70) at a younger age (30 to 39 years). In patients with a history of APM in only one knee, the risk of arthroplasty in that knee was greatly elevated in comparison with the contralateral knee (no APM; HR 2.99; 95% CI 2.95 to 3.02). Conclusion. Patients developing a meniscal tear undergoing APM are at greater risk of knee arthroplasty than the general population. This risk is three-times greater in the patient’s affected knee than in the contralateral knee. Women in the cohort were at double the risk of progressing to knee arthroplasty compared with men. These important new reference data will inform shared decision making and enhance approaches to treatment, prevention, and clinical surveillance. Cite this article: Bone Joint J 2019;101-B:1071–1080


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 46 - 52
1 Jan 2019
León SA Mei XY Safir OA Gross AE Kuzyk PR

Aims. The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function. Patients and Methods. We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score. Results. A total of 14 grafts (23.3%) failed at a mean of 8.6 years (1.4 to 20.1). Graft survivorship was 87.3% (95% confidence interval (CI) 79.0 to 96.6), 85.0% (95% CI 75.8 to 95.3), 74.8% (95% CI 62.2 to 90.0), 65.2% (95% CI 49.9 to 85.2), and 59.8% (95% CI 43.5 to 82.1) at five, ten, 15, 20, and 25 years, respectively. A total of 23 patients (38.3%) developed complications, and 26 (43.3%) had a further operation. Persistent postoperative malalignment occurred more frequently in failed grafts (28.6% vs 4.3%; p = 0.023), and was a risk factor for graft failure (hazard ratio 6.55; 95% CI 1.61 27.71; p = 0.009). The mean mHSS score improved from 74.1 (40 to 91) preoperatively to 89.0 (66 to 100) at final follow-up (p < 0.001). Conclusion. Femoral condylar FOCA with concomitant realignment osteotomy provides excellent long-term graft survival and reliable functional improvement. Persistent malalignment may increase the risk for graft failure


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 592 - 596
1 May 2008
Akizuki S Shibakawa A Takizawa T Yamazaki I Horiuchi H

We carried out a prospective study of 132 patients (159 knees) who underwent closed-wedge high tibial osteotomy for severe medial compartment osteoarthritis between 1988 and 1997. A total of 94 patients (118 knees) was available for review at a mean of 16.4 years (16 to 20). Seven patients (7.4%) (11 knees) required conversion to total knee replacement. Kaplan-Meier survival was 97.6% (95% confidence interval 95.0 to 100) at ten years and 90.4% (95% confidence interval 84.1 to 96.7) at 15 years. Excellent and good results as assessed by the Hospital for Special Surgery knee score were achieved in 87 knees (73.7%). A pre-operative body mass index > 27.5 kg/m. 2. and range of movement < 100° were risk factors predicting early failure. Although our long-term results were satisfactory, strict indications for osteotomy are required if long-term survival is required


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1067 - 1070
1 Aug 2012
Melton JTK Mayahi R Baxter SE Facek M Glezos C

A consecutive series of patients with a hydroxyapatite-coated uncemented total knee replacement (TKR) performed by a single surgeon between 1992 and 1995 was analysed. All patients were invited for clinical review and radiological assessment. Revision for aseptic loosening was the primary outcome. Assessment was based on the Knee Society clinical score (KSS) and an independent radiological analysis. Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in 31 patients lost to follow-up had a mean KSS of 176 (148 to 198) at a mean of ten years. There were revisions in 26 TKRs (5.5%), of which 11 (2.3%) were for aseptic loosening. Other further surgery was carried out on 49 TKRs (10.4%) including patellar resurfacing in 20, arthrolysis in 19, manipulation under anaesthetic in nine and extensor mechanism reconstruction in one. Survivorship at up to 18 years without aseptic loosening was 96% (95% confidence interval 91.9 to 98.1), at which point the mean KSS was 176 (134 to 200). Of 110 knees that underwent radiological evaluation, osteolysis was observed in five (4.5%), one of which was revised. These data indicate that uncemented hydroxyapatite-coated TKR can achieve favourable long-term survivorship, at least as good as that of cemented designs


Bone & Joint Research
Vol. 3, Issue 10 | Pages 297 - 304
1 Oct 2014
Fitch DA Sedacki K Yang Y

Objectives. This systematic review and meta-analysis was conducted to determine the mid- to long-term clinical outcomes for a medial-pivot total knee replacement (TKR) system. The objectives were to synthesise available survivorship, Knee Society Scores (KSS), and reasons for revision for this system. Methods. A systematic search was conducted of two online databases to identify sources of survivorship, KSS, and reasons for revision. Survivorship results were compared with values in the National Joint Registry of England, Wales, and Northern Ireland (NJR). Results. A total of eight studies that included data for 1146 TKRs performed in six countries satisfied the inclusion/exclusion criteria. Pooled component survivorship estimates were 99.2% (95% CI, 97.7 to 99.7) and 97.6% (95% CI, 95.8 to 98.6) at five and eight years, respectively. Survivorship was similar or better when compared with rates reported for all cemented TKRs combined in the NJR and was significantly better than some insert types at mid-term intervals. The weighted mean post-operative KSS was 87.9 (73.2 to 94.2), in the excellent range. Similar cumulative revision rates and KSS were reported at centres in the United States, Europe, and Asia. Conclusions. The subject system was associated with survivorship and KSS similar or better than that reported for other TKR systems. Cite this article: Bone Joint Res 2014;3:297–304


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 45 - 51
1 Jan 2013
Williams DP Blakey CM Hadfield SG Murray DW Price AJ Field RE

The Oxford knee score (OKS) is a validated and widely accepted disease-specific patient-reported outcome measure, but there is limited evidence regarding any long-term trends in the score. We reviewed 5600 individual OKS questionnaires (1547 patients) from a prospectively-collected knee replacement database, to determine the trends in OKS over a ten-year period following total knee replacement. The mean OKS pre-operatively was 19.5 (95% confidence interval (CI) 18.8 to 20.2). The maximum post-operative OKS was observed at two years (mean score 34.4 (95% CI 33.7 to 35.2)), following which a gradual but significant decline was observed through to the ten-year assessment (mean score 30.1 (95% CI 29.1 to 31.1)) (p < 0.001). A similar trend was observed for most of the individual OKS components (p < 0.001). Kneeling ability initially improved in the first year but was then followed by rapid deterioration (p < 0.001). Pain severity exhibited the greatest improvement, although residual pain was reported in over two-thirds of patients post-operatively, and peak improvement in the night pain component did not occur until year four. Post-operative OKS was lower for women (p < 0.001), those aged < 60 years (p < 0.003) and those with a body mass index > 35 kg/m. 2. (p < 0.014), although similar changes in scores were observed. This information may assist surgeons in advising patients of their expected outcomes, as well as providing a comparative benchmark for evaluating longer-term outcomes following knee replacement. Cite this article: Bone Joint J 2013;95-B:45–51


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 836 - 840
1 Aug 2003
Kooijman HJ Driessen APPM van Horn JR

We studied retrospectively the outcome of patellofemoral arthroplasty (PFA) using the Richards prosthesis in 51 patients (56 knees). Their mean age was 50 years (30 to 77). In 43 patients (45 knees), the American Knee Society score and the patients’ subjective judgement were assessed. Excellent or good results were obtained in 86% of cases at a mean follow-up of 17 years (15 to 21). Because of ongoing tibiofemoral osteoarthritis, two patients required a high tibial osteotomy and ten PFAs were converted to a total knee arthroplasty after a mean of 15.6 years (10 to 21). The PFAs were stable during follow-up with a loosening rate of only 2%. We conclude that a patellofemoral prosthesis is a good treatment option with successful long-term results in middle-aged patients with radiologically documented, isolated, patellofemoral osteoarthritis


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1497 - 1499
1 Nov 2013
Abram SGF Nicol F Hullin MG Spencer SJ

We reviewed the long-term clinical and radiological results of 63 uncemented Low Contact Stress (LCS) total knee replacements (TKRs) in 47 patients with rheumatoid arthritis. The mean age of the patients at the time of surgery was 69 years (53 to 81). At a mean follow-up of 22 years (20 to 25), 12 patients were alive (17 TKRs), 27 had died (36 TKRs), and eight (ten TKRs) were lost to follow-up. Revision was necessary in seven patients (seven TKRs, 11.1%) at a mean of 12.1 years (0 to 19) after surgery. In the surviving ten patients who had not undergone revision (15 TKRs), the mean Oxford knee score was 30.2 (16 to 41) at a mean follow-up of 19.5 years (15 to 24.7) and mean active flexion was 105° (90° to 150°). The survival rate was 88.9% at 20 years (56 of 63) and the Kaplan–Meier survival estimate, without revision, was 80.2% (95% confidence interval 37 to 100) at 25 years. Cite this article: Bone Joint J 2013;95-B:1497–9


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 337 - 343
1 Mar 2017
Ahmed I Salmon L Roe J Pinczewski L

Aims. The aim of this study was to investigate the long-term clinical and radiological outcome of patients who suffer recurrent injuries to the anterior cruciate ligament (ACL) after reconstruction and require revision surgery. Patients and Methods. From a consecutive series of 200 patients who underwent primary reconstruction following rupture of the ACL, we identified 36 who sustained a further rupture, 29 of whom underwent revision surgery. Patients were reviewed prospectively at one, two, seven, 15 and about 20 years after their original surgery. Primary outcome measures were the number of further ruptures, the posterior tibial slope (PTS), and functional and radiological outcomes. These were compared with a gender and age matched cohort of patients who underwent primary ACL reconstruction only. Results. At a mean follow-up of 18.3 years (14.3 to 20.2), 29 patients had undergone revision surgery and within this revision group 11 had sustained more than three ruptures of the ACL (3 to 6). The mean age at the time of revision reconstruction was 26.4 years (14 to 54). The mean PTS was significantly higher in those patients who suffered a further injury to the ACL (11°) compared with the control group (9°) (p < 0.001). The mean PTS in those patients who sustained more than three ruptures was 12°. Conclusion. Patients who suffer recurrent injuries to the ACL after reconstruction have poorer functional and radiological outcomes than those who suffer a single injury. The causes of further injury are likely to be multifactorial but an increased PTS appears to have a significant association with recurrent ACL injuries. Cite this article: Bone Joint J 2017;99-B:337–43


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 355 - 358
1 Apr 2001
Gill GS Joshi AB

We present the long-term results of the Kinematic Condylar Knee Arthroplasty followed in a prospective fashion. Between October 1982 and March 1988, 404 consecutive replacement arthroplasties were carried out on 335 patients. Of these, 354 knees had osteoarthritis, 45 rheumatoid arthritis and five other diagnoses. At the time of final follow-up 158 patients (188 knees) had died. No patient was lost to follow-up. The minimum follow-up for all living patients was ten years (10 to 17). The mean age at surgery was 68 years (30 to 92). There were seven complications (1.7%). Sixteen knees (3.9%) were revised, four because of infection. Survivorship was 99.4% (CI 97.9 to 99.8) at five years, 98.2% (CI 96.1 to 99.2) at ten years and 92.6% (CI 87.6 to 95.6) at 17 years


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 660 - 666
1 Jun 2019
Chalmers BP Limberg AK Athey AG Perry KI Pagnano MW Abdel MP

Aims

There is little literature about total knee arthroplasty (TKA) after distal femoral osteotomy (DFO). Consequently, the purpose of this study was to analyze the outcomes of TKA after DFO, with particular emphasis on: survivorship free from aseptic loosening, revision, or any re-operation; complications; radiological results; and clinical outcome.

Patients and Methods

We retrospectively reviewed 29 patients (17 women, 12 men) from our total joint registry who had undergone 31 cemented TKAs after a DFO between 2000 and 2012. Their mean age at TKA was 51 years (22 to 76) and their mean body mass index 32 kg/m2 (20 to 45). The mean time between DFO and TKA was ten years (2 to 20). The mean follow-up from TKA was ten years (2 to 16). The prostheses were posterior-stabilized in 77%, varus-valgus constraint (VVC) in 13%, and cruciate-retaining in 10%. While no patient had metaphyseal fixation (e.g. cones or sleeves), 16% needed a femoral stem.


Bone & Joint Research
Vol. 8, Issue 11 | Pages 535 - 543
1 Nov 2019
Mohammad HR Campi S Kennedy JA Judge A Murray DW Mellon SJ

Objectives

The aim of this study was to determine the polyethylene wear rate of Phase 3 Oxford Unicompartmental Knee Replacement bearings and to investigate the effects of resin type and manufacturing process.

Methods

A total of 63 patients with at least ten years’ follow-up with three bearing types (1900 resin machined, 1050 resin machined, and 1050 resin moulded) were recruited. Patients underwent full weight-bearing model-based radiostereometric analysis to determine the bearing thickness. The linear wear rate was estimated from the change in thickness divided by the duration of implantation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1022 - 1026
1 Aug 2006
Langlais F Belot N Ropars M Lambotte JC Thomazeau H

We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibiotic-loaded cement. The mean age at operation was 33 years (13 to 61). No patient was lost to follow-up; 13 patients died and the 19 survivors were examined at a mean follow-up of 12.5 years (4 to 21). Standard revision press-fit cemented stems were used on the side of the joint which was not involved with tumour (26 tibial and six femoral), on this side there was no loosening or osteolysis and stem survival was 100%. On the reconstruction side, custom-made press-fit stems were used and the survival rate, with any cause for revision as an end point, was 88%, but 97% for loosening or osteolysis. This longevity is similar to that achieved at 20 years with the Charnley-Kerboull primary total hip replacement with press-fit cemented femoral components. We recommend this type of fixation when extensive reconstruction of the knee is required. It may also be suitable for older patients requiring revision of a total knee replacement or in difficult situations such as severe deformity and complex articular fractures


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 478 - 485
1 Apr 2013
Naveed MA Ackroyd CE Porteous AJ

We present the ten- to 15-year follow-up of 31 patients (34 knees), who underwent an Elmslie-Trillat tibial tubercle osteotomy for chronic, severe patellar instability, unresponsive to non-operative treatment. The mean age of the patients at the time of surgery was 31 years (18 to 46) and they were reviewed post-operatively, at four years (2 to 8) and then at 12 years (10 to 15). All patients had pre-operative knee radiographs and Cox and Insall knee scores. Superolateral portal arthroscopy was performed per-operatively to document chondral damage and after the osteotomy to assess the stability of the patellofemoral joint. A total of 28 knees (82%) had a varying degree of damage to the articular surface. At final follow-up 25 patients (28 knees) were available for review and underwent clinical examination, radiographs of the knee, and Cox and Insall scoring. Six patients who had no arthroscopic chondral abnormality showed no or only early signs of osteoarthritis on final radiographs; while 12 patients with lower grade chondral damage (grade 1 to 2) showed early to moderate signs of osteoarthritis and six out of ten knees with higher grade chondral damage (grade 3 to 4) showed marked evidence of osteoarthritis; four of these had undergone a knee replacement. In the 22 patients (24 knees) with complete follow-up, 19 knees (79.2%) were reported to have a good or excellent outcome at four years, while 15 knees (62.5%) were reported to have the same at long-term follow-up. The functional and radiological results show that the extent of pre-operatively sustained chondral damage is directly related to the subsequent development of patellofemoral osteoarthritis. Cite this article: Bone Joint J 2013;95-B:478–85


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 328 - 333
1 Mar 2012
Crawford DA Tompkins BJ Baird GO Caskey PM

Most patients (95%) with fibular hemimelia have an absent anterior cruciate ligament (ACL). The purpose of this study was to assess the long-term outcome of such patients with respect to pain and knee function. We performed a retrospective review of patients with fibular hemimelia and associated ACL deficiency previously treated at our institution. Of a possible 66 patients, 23 were sent the Musculoskeletal Outcomes Data Evaluation and Management System (MODEMS) questionnaire and Lysholm knee score to complete. In all, 11 patients completed the MODEMS and nine completed the Lysholm score questionnaire. Their mean age was 37 years (27 to 57) at review. Five patients had undergone an ipsilateral Symes amputation. There was no significant difference in any subsections of the Short-Form 36 scores of our patients compared with age-matched controls. The mean Lysholm knee score was 90.2 (82 to 100). A slight limp was reported in six patients. No patients had episodes of locking of the knee or required a supportive device for walking. Four had occasional instability with sporting activities. . These results suggest that patients with fibular hemimelia and ACL deficiency can live active lives with a similar health status to age-matched controls


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1077 - 1080
1 Aug 2005
Sharma S Nicol F Hullin MG McCreath SW

We analysed the long-term clinical and radiological results of 63 uncemented Low Contact Stress total knee replacements in 47 patients with rheumatoid arthritis. At a mean follow-up of 12.9 years (10 to 16), 36 patients (49 knees) were still alive; three patients (five knees) were lost to follow-up. Revision was necessary in three knees (4.8%) and the rate of infection was 3.2%. The mean clinical and functional Knee Society scores were 90 (30 to 98) and 59 (25 to 90), respectively, at final follow-up and the mean active range of movement was 104° (55° to 120°). The survival rate was 94% at 16 years but 85.5% of patients lost to follow-up were considered as failures. Radiological evidence of impending failure was noted in one knee


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1172 - 1177
1 Sep 2007
Benoit B Laflamme GY Laflamme GH Rouleau D Delisle J Morin B

We retrospectively reviewed the operative treatment carried out between 1988 and 1994 of eight patients with habitual patellar dislocation. In four the condition was bilateral. All patients had recurrent dislocation with severe functional disability. The surgical technique involved distal advancement of the patella by complete mobilisation of the patellar tendon, lateral release and advancement of vastus medialis obliquus. The long-term results were assessed radiologically, clinically and functionally using the Lysholm knee score, by an independent observer. The mean age at operation was 10.3 years (7 to 14) with a mean follow-up of 13.5 years (11 to 16). One patient required revision. At the latest follow-up, all patellae were stable and knees functional with a mean Lysholm knee score of 98 points (95 to 100). In those aged younger than ten years at operation there was a statistically significant improvement in the sulcus angle at the latest follow-up (Student’s t-test, p = 0.001). Two patients developed asymptomatic patella infera as a late complication. This technique offers a satisfactory treatment for the immature patient presenting with habitual patellar dislocation associated with patella alta. If performed early, we believe that remodelling of the shallow trochlea may occur, adding intrinsic patellofemoral stability


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 601 - 607
1 May 2016
McClelland D Barlow D Moores TS Wynn-Jones C Griffiths D Ogrodnik PJ Thomas PBM

In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty. . Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up. At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5). . HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term. . Cite this article: Bone Joint J 2016;98-B:601–7


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1317 - 1323
1 Oct 2007
Kim Y Yoon S Kim J

We compared the results of 146 patients who received an anatomic modular knee fixed-bearing total knee replacement (TKR) in one knee and a low contact stress rotating platform mobile-bearing TKR in the other. There were 138 women and eight men with a mean age of 69.8 years (42 to 80). The mean follow-up was 13.2 years (11.0 to 14.5). The patients were assessed clinically and radiologically using the rating systems of the Hospital for Special Surgery and the Knee Society at three months, six months, one year, and annually thereafter. The assessment scores of both rating systems pre-operatively and at the final review did not show any statistically significant differences between the two designs of implant. In the anatomic modular knee group, one knee was revised because of aseptic loosening of the tibial component and one because of infection. In addition, three knees were revised because of wear of the polyethylene tibial bearing. In the low contact stress group, two knees were revised because of instability requiring exchange of the polyethylene insert and one because of infection. The radiological analysis found no statistical difference in the incidence of radiolucent lines at the final review (Student’s t-test, p = 0.08), most of which occurred at tibial zone 1. The Kaplan-Meier survivorship for aseptic loosening of the anatomic modular knee and the low contact stress implants at 14.5 years was 99% and 100%, respectively, with a 95% confidence interval of 94% to 100% for both designs. We found no evidence of the superiority of one design over the other at long-term follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 510 - 512
1 May 2001
Gill GS Joshi AB

We analysed the long-term results with a mean follow-up of 10.2 years, of 66 total knee replacements in 42 patients with rheumatoid arthritis. In all cases the posterior cruciate ligament was retained. There were only three complications (4.5%). Revision surgery was necessary in five knees (7.6%), including one (1.5%) with infection. At the final follow-up, 75.8% of knees were rated excellent clinically. Only 15% had an excellent function score. The survival rate of the implant was 90.7% at 19 years. The clinical, radiological and survivorship analysis shows that the posterior-cruciate-retaining knee arthroplasty performs well in rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 937 - 940
1 Jul 2012
Manopoulos P Havet E Pearce O Lardanchet JF Mertl P

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 941 - 948
1 Jul 2010
Stone KR Adelson WS Pelsis JR Walgenbach AW Turek TJ

We describe 119 meniscal allograft transplantations performed concurrently with articular cartilage repair in 115 patients with severe articular cartilage damage. In all, 53 (46.1%) of the patients were over the age of 50 at the time of surgery. The mean follow-up was for 5.8 years (2 months to 12.3 years), with 25 procedures (20.1%) failing at a mean of 4.6 years (2 months to 10.4 years). Of these, 18 progressed to knee replacement at a mean of 5.1 years (1.3 to 10.4). The Kaplan-Meier estimated mean survival time for the whole series was 9.9 years (sd 0.4). Cox’s proportional hazards model was used to assess the effect of covariates on survival, with age at the time of surgery (p = 0.026) and number of previous operations (p = 0.006) found to be significant.

The survival of the transplant was not affected by gender, the severity of cartilage damage, axial alignment, the degree of narrowing of the joint space or medial versus lateral allograft transplantation. Patients experienced significant improvements at all periods of follow-up in subjective outcome measures of pain, activity and function (all p-values < 0.05), with the exception of the seven-year Tegner index score (p = 0.076).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 185 - 189
1 Feb 2012
Lim H Bae J Park Y Park Y Park J Park J Suh D

The purpose of this study was to evaluate the long-term functional and radiological outcomes of arthroscopic removal of unstable osteochondral lesions with subchondral drilling in the lateral femoral condyle. We reviewed the outcome of 23 patients (28 knees) with stage III or IV osteochondritis dissecans lesions of the lateral femoral condyle at a mean follow-up of 14 years (10 to 19). The functional clinical outcomes were assessed using the Lysholm score, which improved from a mean of 38.1 (sd 3.5) pre-operatively to a mean of 87.3 (sd 5.4) at the most recent review (p = 0.034), and the Tegner activity score, which improved from a pre-operative median of 2 (0 to 3) to a median of 5 (3 to 7) at final follow-up (p = 0.021). The radiological degenerative changes were evaluated according to Tapper and Hoover’s classification and when compared with the pre-operative findings, one knee had grade 1, 22 knees had grade 2 and five knees had grade 3 degenerative changes. The overall outcomes were assessed using Hughston’s rating scale, where 19 knees were rated as good, four as fair and five as poor.

We found radiological evidence of degenerative changes in the third or fourth decade of life at a mean of 14 years after arthroscopic excision of the loose body and subchondral drilling for an unstable osteochondral lesion of the lateral femoral condyle. Clinical and functional results were more satisfactory.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1096 - 1099
1 Aug 2010
Sutherland AG Cooper K Alexander LA Nicol M Smith FW Scotland TR

We identified a series of 128 patients who had unilateral open reconstruction of the anterior cruciate ligament (ACL) by a single surgeon between 1993 and 2000. In all, 79 patients were reviewed clinically and radiologically eight to 15 years after surgery. Assessment included measurement of the Lysholm and Tegner scores, the ACL quality-of-life score and the Short Form-12 score, as well as the International Knee Documentation Committee clinical assessment, measurement of laxity by the KT-1000 arthrometer, a single-leg hop test and standardised radiography of both knees using the uninjured knee as a control.

Of the injured knees, 46 (57%) had definite radiological evidence of osteoarthritis (Kellgren-Lawrence grade 2 or 3), with a mean difference between the injured and non-injured knees of 1.2 grades. The median ACL quality-of-life score was 80 (interquartile range (IQR) 60 to 90), the Lysholm score 84 (IQR 74 to 95), the Short Form-12 physical component score 54 (IQR 49 to 56) and the mean Hop Index 0.94 (0.52 to 1.52). In total 58 patients were graded as normal, 20 as nearly normal and one as abnormal on the KT-1000 assessment and pivot-shift testing. Taking the worst-case scenario of assuming all non-attenders (n = 48), two septic failures and one identified unstable knee found at review to be failures, the failure rate was 40%. Only two of the patients reviewed stated that they would not have similar surgery again.

Open reconstruction of the ACL gives good, durable functional results, but with a high rate of radiologically evident osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1366 - 1371
1 Oct 2012
Pijls BG Valstar ER Kaptein BL Nelissen RGHH

This single-blinded randomised controlled trial investigated whether one design of mobile-bearing (MB) total knee replacement (TKR) has any advantage over a fixed-bearing (FB) design on long-term fixation as measured by radiostereometry. The amount of wear underneath the mobile bearing was also evaluated. A series of 42 knees was randomised to MB or FB tibial components with appropriate polyethylene inserts and followed for between ten and 12 years, or until the death of the patient. The polyethylene in the MB group was superior in that it was gamma-irradiated in inert gas and was calcium-stearate free; the polyethylene in the FB group was gamma-irradiated in air and contained calcium stearate. In theory this should be advantageous to the wear rate of the MB group. At final follow-up the overall mean migration was 0.75 mm (sd 0.76) in the MB group and 0.66 mm (sd 0.4) in the FB group, with the FB group demonstrating more posterior tilt and the MB group more internal rotation. In the FB group there was one revision for aseptic loosening, but none in the MB group. There were no significant differences in clinical or radiological scores.

For the MB group, the mean linear wear rate on the under-surface was 0.026 mm/year (sd 0.014). This was significantly smaller than the wear rate of 0.11 mm/year (sd 0.06) in the MB between femur and polyethylene (p < 0.001). Nevertheless, even in a best-case setting the mobile bearings of this TKR design had no apparent advantage in terms of fixation over the FB knee prosthesis at ten to 12 years. The wear underneath the mobile bearing was small and is unlikely to be clinically relevant.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 217 - 221
1 Feb 2010
Hahn SB Choi YR Kang HJ Lee SH

Between 1987 and 2006 we performed a modified Thompson’s quadricepsplasty on 40 fracture-related stiff knees and followed the patients for a mean of 7.9 years (2 to 11.1). The factors affecting the final gain of movement were investigated. A total of 15 knees required lengthening of the rectus femoris. The mean flexion gain was 70.2° (42.3° to 112.5°). According to Judet’s criteria, the results were excellent in 30 knees, good in seven, and fair in three. The range of movement which was achieved intra-operatively was related to the gain of knee flexion on univariate analysis. Five patients had complications: deep infection in one, recurrent patellar dislocation in one, and rupture of the extensor mechanism in three. This modified technique gives satisfactory results. Achieving maximum knee flexion intra-operatively seems to be the most important factor in enhancing the outcome in patients with stiffness of the knee following fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 861 - 864
1 Aug 2002
Nakagawa K Wada Y Minamide M Tsuchiya A Moriya H

We examined an39 patients (45 knees) who had undergone Elmslie-Trillat procedure for recurrent or habitual dislocation of the patella with a follow-up of more than ten years. The mean age at the time of surgery was 18.4 years; the mean follow-up was 161 months (120 to 238). Using Fulkerson’s functional knee score, 41 knees (91%) had an excellent or good result at a mean follow-up of 45 months, and this was maintained in 29 (64%) at the final review.

The main cause of deterioration in the clinical results was the onset or worsening of patellofemoral joint pain, not patellar instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 513 - 516
1 May 2001
Hoser C Fink C Brown C Reichkendler M Hackl W Bartlett J

We evaluated the outcome of partial lateral meniscectomy of 31 knees in 29 patients whose knees were otherwise normal. The mean follow-up was 10.3 years.

According to the Lysholm score, 14 knees were rated as excellent, four as good, five as fair and eight as poor, with a mean score of 80.5 points. Radiologically, only one lateral compartment was classified as grade 0, eight as grade 1, nine as grade 2, 11 as grade 3, and two as grade 4 according to Tapper and Hoover. No significant (p < 0.05) correlation was found between the amount of tissue resected and the subjective, clinical and radiological outcome.

Although early results of lateral meniscectomy may be satisfactory, we have demonstrated that in the long term there was a high incidence of degenerative changes, a high rate of reoperation (29%) and a relatively low functional outcome score.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 599 - 603
1 May 2007
Robertsson O Stefánsdòttir A Lidgren L Ranstam J

Patients with osteoarthritis undergoing knee replacement have been reported to have an overall reduced mortality compared with that of the general population. This has been attributed to the selection of healthier patients for surgery. However, previous studies have had a maximum follow-up time of ten years. We have used information from the Swedish Knee Arthroplasty Register to study the mortality of a large national series of patients with total knee replacement for up to 28 years after surgery and compared their mortality with that of the normal population. In addition, for a subgroup of patients operated on between 1980 and 2002 we analysed their registered causes of death to determine if they differed from those expected.

We found a reduced overall mortality during the first 12 post-operative years after which it increased and became significantly higher than that of the general population. Age-specific analysis indicated an inverse correlation between age and mortality, where the younger the patients were, the higher their mortality. The shift at 12 years was caused by a relative over-representation of younger patients with a longer follow-up. Analysis of specific causes of death showed a higher mortality for cardiovascular, gastrointestinal and urogenital diseases. The observation that early onset of osteoarthritis of the knee which has been treated by total knee replacement is linked to an increased mortality should be a reason for increased general awareness of health problems in these patients.


Aims. The use of high tibial osteotomy (HTO) to delay total knee arthroplasty (TKA) in young patients with osteoarthritis (OA) and constitutional deformity remains debated. The aim of this study was to compare the long-term outcomes of TKA after HTO compared to TKA without HTO, using the time from the index OA surgery as reference (HTO for the study group, TKA for the control group). Methods. This was a case-control study of consecutive patients receiving a posterior-stabilized TKA for OA between 1996 and 2010 with previous HTO. A total of 73 TKAs after HTO with minimum ten years’ follow-up were included. Cases were matched with a TKA without previous HTO for age at the time of the HTO. All revisions were recorded. Kaplan-Meier survivorship analysis was performed using revision of metal component as the endpoint. The Knee Society Score, range of motion, and patient satisfaction were assessed. Results. Mean follow-up was 13 years (SD 3) after TKA in both groups. The 20-year Kaplan-Meier survival estimate was 98.6% in TKA post-HTO group (HTO as timing reference) and 81.4% in control group (TKA as timing reference) (p = 0.030). There was no significant difference in clinical outcomes, radiological outcomes, and complications at the last follow-up. Conclusion. At the same delay from index surgery (HTO or TKA), a strategy of HTO followed by TKA had superior knee survivorship compared to early TKA at long term in young patients. Level of evidence: III. Cite this article: Bone Jt Open 2023;4(2):62–71


Bone & Joint Open
Vol. 5, Issue 5 | Pages 401 - 410
20 May 2024
Bayoumi T Burger JA van der List JP Sierevelt IN Spekenbrink-Spooren A Pearle AD Kerkhoffs GMMJ Zuiderbaan HA

Aims. The primary objective of this registry-based study was to compare patient-reported outcomes of cementless and cemented medial unicompartmental knee arthroplasty (UKA) during the first postoperative year. The secondary objective was to assess one- and three-year implant survival of both fixation techniques. Methods. We analyzed 10,862 cementless and 7,917 cemented UKA cases enrolled in the Dutch Arthroplasty Registry, operated between 2017 and 2021. Pre- to postoperative change in outcomes at six and 12 months’ follow-up were compared using mixed model analyses. Kaplan-Meier and Cox regression models were applied to quantify differences in implant survival. Adjustments were made for patient-specific variables and annual hospital volume. Results. Change from baseline in the Oxford Knee Score (OKS) and activity-related pain was comparable between groups. Adjustment for covariates demonstrated a minimally greater decrease in rest-related pain in the cemented group (β = -0.09 (95% confidence interval (CI) -0.16 to -0.01)). Cementless fixation was associated with a higher probability of achieving an excellent OKS outcome (> 41 points) (adjusted odds ratio 1.2 (95% CI 1.1 to 1.3)). The likelihood of one-year implant survival was greater for cemented implants (adjusted hazard ratio (HR) 1.35 (95% CI 1.01 to 1.71)), with higher revision rates for periprosthetic fractures of cementless implants. During two to three years’ follow-up, the likelihood of implant survival was non-significantly greater for cementless UKA (adjusted HR 0.64 (95% CI 0.40 to 1.04)), primarily due to increased revision rates for tibial loosening of cemented implants. Conclusion. Cementless and cemented medial UKA led to comparable improvement in physical function and pain reduction during the initial postoperative year, albeit with a greater likelihood of achieving excellent OKS outcomes after cementless UKA. Anticipated differences in early physical function and pain should not be a decisive factor in the choice of fixation technique. However, surgeons should consider the differences in short- and long-term implant survival when deciding which implant to use. Cite this article: Bone Jt Open 2024;5(5):401–410


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims. A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Methods. Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits. Results. The patient cohort mean age was 66 years (SD seven years), 59% were female, and the mean BMI was 32 kg/m. 2. (SD 6 kg/m. 2. ). Mean two-year subsidence of the EF-TKA was 0.056 mm (95% confidence interval (CI) 0.025 to 0.086) versus 0.006 mm (95% CI -0.029 to 0.040) for the Std-TKA, and the two-year maximum total point motion (MTPM) was 0.285 mm (95% upper confidence limit (UCL) ≤ 0.363) versus 0.346 mm (95% UCL ≤ 0.432), respectively, for a mean difference of -0.061 mm (95% CI -0.196 to 0.074). Inducible displacement also did not differ between groups. The MTPMs between 12 and 24 months for each group was below the published threshold of 0.2 mm for predicting early aseptic loosening (p < 0.001 and p = 0.001, respectively). Conclusion. Both the enhanced fixation and the standard tibial implant design showed fixation with a predicted low risk of long-term aseptic loosening. Cite this article: Bone Jt Open 2024;5(1):20–27


Bone & Joint Open
Vol. 5, Issue 10 | Pages 937 - 943
22 Oct 2024
Gregor RH Hooper GJ Frampton C

Aims. The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs). Methods. This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period. Results. Obese patients (BMI > 30 kg/m. 2. ) were 3.1 years younger than non-obese patients (BMI < 30 kg/m. 2. ) at the time of surgery (mean age of obese patients 65.5 years (SD 9.7) and mean age of non-obese patients 68.6 years (SD 10.1)). Preoperatively, obese patients tended to have significantly lower functional scores than non-obese patients, which continued at five and ten years postoperatively. At these timepoints, obese patients had significantly lower scores for most PROMs measured compared to non-obese patients. However, there was no significant difference in the improvement of any of these scores after surgery between obese and non-obese patients. There was no significant difference in revision rates between obese and non-obese patients at any time. All-cause revision rate for obese patients was 0.73 per 100 observed component years compared to 0.67 in non-obese patients at ten years. There was also no significant difference in the aseptic loosening rate between groups. Conclusion. Our study supports the use of UKAs in obese patients, with similar benefit and survival compared to non-obese patients at ten years


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1168 - 1176
1 Nov 2023
Yüksel Y Koster LA Kaptein BL Nelissen RGHH den Hollander P

Aims. Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes. Methods. A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months’ follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively. Results. At five-year follow-up, RSA data from 61 patients were available and the mean maximum total point motion (MTPM) of the femoral components were: ATTUNE: 0.96 mm (95% confidence interval (CI) 0.79 to 1.14) and PFC-Sigma 1.37 mm (95% CI 1.18 to 1.59) (p < 0.001). The PFC-Sigma femoral component migrated more in the first postoperative year, but stabilized thereafter. MPTM of the tibial components were comparable at five-year follow-up: ATTUNE 1.12 mm (95% CI 0.95 to 1.31) and PFC-Sigma 1.25 mm (95% CI 1.07 to 1.44) (p = 0.438). RLL at the medial tibial implant-cement interface remained more prevalent for the ATTUNE at five-year follow-up compared to the PFC-Sigma (20% vs 3%). RLL did not progress over time, and varied between patients at different timepoints for both TKA systems. Clinical outcomes and PROMs improved compared with preoperative scores, and were not different between groups. Conclusion. MTPM migration at five-year follow-up of the femoral and tibial component of the ATTUNE were similar and as low as that of the PFC-Sigma. MTPM migration of both knee implants did not significantly change from one year post-surgery, indicating stable fixation. Long-term ATTUNE performance may be expected to be comparable to the clinically well-performing PFC-Sigma. We have not found evidence of increased tibial component migration as measured by RSA to support concerns about cement debonding and a higher risk of aseptic loosening with the ATTUNE TKA. Cite this article: Bone Joint J 2023;105-B(11):1168–1176


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims. Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up. Methods. Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk. Results. Fewer TKA patients with ‘poor’ outcomes (≤ 25) subsequently underwent revision compared with UKA at six months (5.1% vs 19.6%; p < 0.001), five years (4.3% vs 12.5%; p < 0.001), and ten years (6.4% vs 15.0%; p = 0.024). Compared with TKA, the relative risk for UKA was 2.5-times higher for ‘unknown’ reasons, bearing dislocations, and disease progression. Conclusion. Compared with TKA, more UKA patients with poor outcomes underwent revision from early to long-term follow-up, and were more likely to undergo revision for ‘unknown’ reasons, which suggest a lower clinical threshold for UKA. For UKA, revision risk was higher for bearing dislocations and disease progression. There is supporting evidence that the higher revision UKA rates are associated with lower clinical thresholds for revision and additional modes of failure. Cite this article: Bone Joint J 2023;105-B(3):269–276


Bone & Joint Open
Vol. 4, Issue 6 | Pages 457 - 462
26 Jun 2023
Bredgaard Jensen C Gromov K Petersen PB Jørgensen CC Kehlet H Troelsen A

Aims. Medial unicompartmental knee arthroplasty (mUKA) is an advised treatment for anteromedial knee osteoarthritis. While long-term survival after mUKA is well described, reported incidences of short-term surgical complications vary and the effect of surgical usage on complications is less established. We aimed to describe the overall occurrence and treatment of surgical complications within 90 days of mUKA, as well as occurrence in high-usage centres compared to low-usage centres. Methods. mUKAs performed in eight fast-track centres from February 2010 to June 2018 were included from the Lundbeck Foundation Centre for Fast-track Hip and Knee Replacement Database. All readmissions within 90 days of surgery underwent chart review and readmissions related to the surgical wound or the prosthesis were recorded. Centres were categorized as high-usage centres when using mUKA in ≥ 20% of annual knee arthroplasties. The occurrence of complications between high- and low-usage centres were compared using Fisher’s exact test. Results. We included 3,757 mUKAs: 2,377 mUKAs from high-usage centres and 1,380 mUKAs from low-usage centres. Surgical complications within 90 days occurred in 69 cases (1.8%), 45 (1.9%) in high-usage centres and 24 (1.7%) in low-usage centres (odds ratio (OR) 1.1 (95% confidence interval (CI) 0.65 to 1.8)). The most frequent complications were periprosthetic joint infections (PJIs) (n = 18; 0.48%), wound-related issues (n = 14; 0.37%), and periprosthetic fractures (n = 13; 0.35%). Bearing dislocations (n = 7; 0.19%) occurred primarily in procedures from high-usage centres. In high-usage centres, seven periprosthetic fractures (0.29%) occurred compared to six (0.43%) in low-usage centres (OR 0.68 (95% CI 0.20 to 2.0)). In high-usage centres, nine PJIs (0.38%) occurred compared to nine (0.65%) in low-usage centres (OR 0.58 (95% CI 0.22 to 1.6)). Conclusion. Surgical complications are rare after fast-track mUKA surgery and with no difference in overall occurrence of surgical complications between high- and low-usage centres, although the risk of some specific surgical complications may favour high-usage centres. Cite this article: Bone Jt Open 2023;4(6):457–462


Bone & Joint Open
Vol. 4, Issue 10 | Pages 791 - 800
19 Oct 2023
Fontalis A Raj RD Haddad IC Donovan C Plastow R Oussedik S Gabr A Haddad FS

Aims. In-hospital length of stay (LOS) and discharge dispositions following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, it is imperative to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge dispositions following robotic arm-assisted total knee arthroplasty (RO TKA) and unicompartmental arthroplasty (RO UKA) versus conventional technique (CO TKA and UKA). Methods. This large-scale, single-institution study included patients of any age undergoing primary TKA (n = 1,375) or UKA (n = 337) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for post anaesthesia care unit (PACU) admission, anaesthesia type, readmission within 30 days, and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge. Results. The median LOS in the RO TKA group was 76 hours (interquartile range (IQR) 54 to 104) versus 82.5 (IQR 58 to 127) in the CO TKA group (p < 0.001) and 54 hours (IQR 34 to 77) in the RO UKA versus 58 (IQR 35 to 81) in the CO UKA (p = 0.031). Discharge dispositions were comparable between the two groups. A higher percentage of patients undergoing CO TKA required PACU admission (8% vs 5.2%; p = 0.040). Conclusion. Our study showed that robotic arm assistance was associated with a shorter LOS in patients undergoing primary UKA and TKA, and no difference in the discharge destinations. Our results suggest that robotic arm assistance could be advantageous in partly addressing the upsurge of knee arthroplasty procedures and the concomitant healthcare burden; however, this needs to be corroborated by long-term cost-effectiveness analyses and data from randomized controlled studies. Cite this article: Bone Jt Open 2023;4(10):791–800


Bone & Joint Open
Vol. 5, Issue 10 | Pages 911 - 919
21 Oct 2024
Clement N MacDonald DJ Hamilton DF Gaston P

Aims. The aims were to assess whether joint-specific outcome after total knee arthroplasty (TKA) was influenced by implant design over a 12-year follow-up period, and whether patient-related factors were associated with loss to follow-up and mortality risk. Methods. Long-term follow-up of a randomized controlled trial was undertaken. A total of 212 patients were allocated a Triathlon or a Kinemax TKA. Patients were assessed preoperatively, and one, three, eight, and 12 years postoperatively using the Oxford Knee Score (OKS). Reasons for patient lost to follow-up, mortality, and revision were recorded. Results. A total of 94 patients completed 12-year functional follow-up (62 females, mean age 66 years (43 to 82) at index surgery). There was a clinically significantly greater improvement in the OKS at one year (mean difference (MD) 3.0 (95% CI 0.4 to 5.7); p = 0.027) and three years (MD 4.7 (95% CI 1.9 to 7.5); p = 0.001) for the Triathlon group, but no differences were observed at eight (p = 0.331) or 12 years’ (p = 0.181) follow-up. When assessing the OKS in the patients surviving to 12 years, the Triathlon group had a clinically significantly greater improvement in the OKS (marginal mean 3.8 (95% CI 0.2 to 7.4); p = 0.040). Loss to functional follow-up (53%, n = 109/204) was independently associated with older age (p = 0.001). Patient mortality was the major reason (56.4%, n = 62/110) for loss to follow-up. Older age (p < 0.001) and worse preoperative OKS (p = 0.043) were independently associated with increased mortality risk. An age at time of surgery of ≥ 72 years was 75% sensitive and 74% specific for predicting mortality with an area under the curve of 78.1% (95% CI 70.9 to 85.3; p < 0.001). Conclusion. The Triathlon TKA was associated with clinically meaningful greater improvement in knee-specific outcome when compared to the Kinemax TKA. Loss to follow-up at 12 years was a limitation, and studies planning longer-term functional assessment could limit their cohort to patients aged under 72 years. Cite this article: Bone Jt Open 2024;5(10):911–919


Bone & Joint Open
Vol. 2, Issue 6 | Pages 397 - 404
1 Jun 2021
Begum FA Kayani B Magan AA Chang JS Haddad FS

Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship


Bone & Joint Open
Vol. 2, Issue 1 | Pages 48 - 57
19 Jan 2021
Asokan A Plastow R Kayani B Radhakrishnan GT Magan AA Haddad FS

Cementless knee arthroplasty has seen a recent resurgence in popularity due to conceptual advantages, including improved osseointegration providing biological fixation, increased surgical efficiency, and reduced systemic complications associated with cement impaction and wear from cement debris. Increasingly younger and higher demand patients are requiring knee arthroplasty, and as such, there is optimism cementless fixation may improve implant survivorship and functional outcomes. Compared to cemented implants, the National Joint Registry (NJR) currently reports higher revision rates in cementless total knee arthroplasty (TKA), but lower in unicompartmental knee arthroplasty (UKA). However, recent studies are beginning to show excellent outcomes with cementless implants, particularly with UKA which has shown superior performance to cemented varieties. Cementless TKA has yet to show long-term benefit, and currently performs equivalently to cemented in short- to medium-term cohort studies. However, with novel concepts including 3D-printed coatings, robotic-assisted surgery, radiostereometric analysis, and kinematic or functional knee alignment principles, it is hoped they may help improve the outcomes of cementless TKA in the long-term. In addition, though cementless implant costs remain higher due to novel implant coatings, it is speculated cost-effectiveness can be achieved through greater surgical efficiency and potential reduction in revision costs. There is paucity of level one data on long-term outcomes between fixation methods and the cost-effectiveness of modern cementless knee arthroplasty. This review explores recent literature on cementless knee arthroplasty, with regards to clinical outcomes, implant survivorship, complications, and cost-effectiveness; providing a concise update to assist clinicians on implant choice. Cite this article: Bone Jt Open 2021;2(1):48–57


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 98 - 104
1 Jan 2021
van Ooij B Sierevelt IN van der Vis HM Hoornenborg D Haverkamp D

Aims. For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. Methods. A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization. Results. RSA secondary stabilization did not show a significant difference between the three types of fixation. A maximum total point motion of less than 0.2 mm in the second postoperative year was shown in each group, which suggests stabilization of the implant. At 24 months after surgery, PROMs significantly improved compared to baseline in all treatment groups. No significant difference was observed between the three groups. Conclusion. Secondary stabilization measurements in this study demonstrated no significant difference between the groups. In all groups migration stabilized after initial settling of the implant. For this implant the long-term outcome is not expected to be influenced by the type of fixation to the bone. Cite this article: Bone Joint J 2021;103-B(1):98–104


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims. Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m. 2. (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results. At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). Conclusion. Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1043 - 1048
1 Dec 2021

Aims. There is limited information on outcomes of revision ACL reconstruction (rACLR) in soccer (association football) athletes, particularly on return to sport and the rate of additional knee surgery. The purpose of this study was to report return to soccer after rACLR, and to test the hypothesis that patient sex and graft choice are associated with return to play and the likelihood of future knee surgery in soccer players undergoing rACLR. Methods. Soccer athletes enrolled in a prospective multicentre cohort were contacted to collect ancillary data on their participation in soccer and their return to play following rACLR. Information regarding if and when they returned to play and their current playing status was recorded. If they were not currently playing soccer, they were asked the primary reason they stopped playing. Information on any subsequent knee surgery following their index rACLR was also collected. Player demographic data and graft choice were collected from their baseline enrolment data at rACLR. Results. Soccer-specific follow-up was collected on 76% (33 male, 39 female) of 95 soccer athletes. Subsequent surgery information was collected on 95% (44 male, 46 female). Overall, 63% of athletes returned to soccer a mean 9.6 months (SD 5.8) after index revision surgery but participation in soccer decreased to 19% at a mean of 6.4 years (SD 1.3) after surgery. There was no significant association of patient sex or graft choice with return to play, time of return to play, or long-term return to play. Females were more likely than males to have subsequent knee surgery following rACLR (20% (9/46) vs 5% (2/44); p = 0.050). The rate of recurrent graft tear (5.6%; 5/90) was similar between males and females. Conclusion. Approximately two-thirds of soccer players return to sport after rACLR, but the rate of participation drops significantly over time. Neither patient sex nor graft choice at the time of rACLR were associated with return to play. Female soccer players face a higher risk for additional knee surgery after rACLR than male soccer players. Cite this article: Bone Jt Open 2021;2(12):1043–1048


Bone & Joint Open
Vol. 2, Issue 9 | Pages 737 - 744
1 Sep 2021
Øhrn F Lian ØB Tsukanaka M Röhrl SM

Aims. Medial pivot (MP) total knee arthroplasties (TKAs) were designed to mimic native knee kinematics with their deep medial congruent fitting of the tibia to the femur almost like a ball-on-socket, and a flat lateral part. GMK Sphere is a novel MP implant. Our primary aim was to study the migration pattern of the tibial tray of this TKA. Methods. A total of 31 patients were recruited to this single-group radiostereometric analysis (RSA) study and received a medial pivot GMK Sphere TKA. The distributions of male patients versus female patients and right versus left knees were 21:10 and 17:14, respectively. Mean BMI was 29 kg/m. 2. (95% confidence interval (CI) 27 to 30) and mean age at surgery was 63 years (95% CI 61 to 66). Maximum total point motions (MTPMs), medial, proximal, and anterior translations and transversal, internal, and varus rotations were calculated at three, 12, and 24 months. Patient-reported outcome measure data were also retrieved. Results. MTPMs at three, 12, and 24 months were 1.0 mm (95% CI 0.8 to 1.2), 1.3 mm (95% CI 0.9 to 1.7), and 1.4 mm (0.8 to 2.0), respectively. The Forgotten Joint Score was 79 (95% CI 39 to 95) and Knee Injury and Osteoarthritis Outcome Score obtained at two years was 94 (95% CI 81 to 100), 86 (95% CI 75 to 93), 94 (95% CI 88 to 100), 69 (95% CI 48 to 88), and 81 (95% CI59 to 100) for Pain, Symptoms, Activities of Daily Living, Sport & Recreation, and Quality of Life, respectively. Conclusion. In conclusion, we found that the mean increase in MTPM was lower than 0.2 mm between 12 and 24 months and thus apparently stable. Yet the GMK Sphere had higher migration at one and two years than anticipated. Based on current RSA data, we therefore cannot conclude on the long-term performance of the implant, pending further assessment. Cite this article: Bone Jt Open 2021;2(9):737–744


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 855 - 863
1 May 2021
Koster LA Meinardi JE Kaptein BL Van der Linden - Van der Zwaag E Nelissen RGHH

Aims. The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). Methods. A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. Results. A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. Conclusion. The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855–863


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1367 - 1372
1 Aug 2021
Plancher KD Brite JE Briggs KK Petterson SC

Aims. The patient-acceptable symptom state (PASS) is a level of wellbeing, which is measured by the patient. The aim of this study was to determine if the proportion of patients who achieved an acceptable level of function (PASS) after medial unicompartmental knee arthroplasty (UKA) was different based on the status of the anterior cruciate ligament (ACL) at the time of surgery. Methods. A total of 114 patients who underwent UKA for isolated medial osteoarthritis (OA) of the knee were included in the study. Their mean age was 65 years (SD 10). No patient underwent a bilateral procedure. Those who had undergone ACL reconstruction during the previous five years were excluded. The Knee injury Osteoarthritis Outcome Score Activities of Daily Living (KOOS ADL) function score was used as the primary outcome measure with a PASS of 87.5, as described for total knee arthroplasty (TKA). Patients completed all other KOOS subscales, Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the Veterans Rand 12-item health survey score. Failure was defined as conversion to TKA. Results. Survivorship at ten years was 97% in both the ACL-deficient and ACL-intact groups. The mean survival was 16.1 years (95% confidence interval (CI) 15.3 to 16.8) for the ACL-deficient group and 15.6 years (95% CI 14.8 to 16.361) for the ACL-intact group (p = 0.878). At a mean of nine years (SD 3.5) in the ACL-deficient group, 32 patients (87%) reached the PASS for the KOOS ADL. In the ACL-intact group, at a mean of 8.6 years (SD 3) follow-up, 63 patients (85%) reached PASS for the KOOS ADL. There was no significant difference in the percentage of patients who reached PASS for all KOOS subscales and Lysholm between the two groups. Conclusion. PASS was achieved in 85% of all UKAs for KOOS ADL, similar to reports for TKA. Fixed-bearing, medial, non-robotically-assisted UKA resulted in 97% survival at ten years in both the ACL-deficient and ACL-intact groups. There was no significant difference in all outcomes between the two groups. Understanding PASS will allow better communication between surgeons and patients to improve the surgical management of patients with single compartment OA of the knee. This study provides mid- to long-term data supporting the use of PASS to document outcomes following UKA. PASS was met in more than 85% of patients with no differences between ACL-deficient and ACL-intact knees at a mean follow-up of nine years. Cite this article: Bone Joint J 2021;103-B(8):1367–1372


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 116 - 122
1 Jun 2020
Bedard NA Cates RA Lewallen DG Sierra RJ Hanssen AD Berry DJ Abdel MP

Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in relation to implant fixation. Moreover, radiographs revealed incorporation of the bone graft and biological fixation of the cone. While long-term follow-up will be important, this technique provides an excellent option for the management of complex revision TKAs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):116–122


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 32 - 37
1 Jun 2021
Restrepo S Smith EB Hozack WJ

Aims. Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. Methods. This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years follow-up. Outcomes were determined by comparing pre- and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores, and pre- and postoperative 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores. Aseptic loosening and revision for any reason were the endpoints which were used to determine survivorship at five years. Results. At mid-term follow-up, the mean KOOS JR score improved significantly from 33.14 (0 t0 85, standard deviation (SD) 21.88) preoperatively to 84.12 (15.94 to 100, SD 20.51) postoperatively (p < 0.001), the mean VR/SF-12 scores improved significantly from physical health (PH), 31.21 (SD 5.32; 23.99 to 56.77) preoperatively to 42.62 (SD 10.72; 19.38 to 56.82) postoperatively (p < 0.001) and the mental health (MH), 38.15 (SD 8.17; 19.06 to 60.75) preoperatively to 55.09 (SD 9.64; 19.06 to 66.98) postoperatively (p < 0.001). A total of 11 revisions were undertaken, with an overall revision rate of 2.94%, including five for periprosthetic joint infection (1.34%), three for loosening (0.80%), two for instability (0.53%), and one for pain (0.27%). The overall survivorship was 97.06% and survivorship for aseptic loosening as the endpoint was 98.40%, with a 99.5% survivorship of the 3D-printed tibial component. Conclusion. This 3D-printed cementless total knee system shows excellent survivorship at mid-term follow-up. This design and the ability to obtain cementless fixation offers promise for excellent long-term durability. Cite this article: Bone Joint J 2021;103-B(6 Supple A):32–37


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 51 - 58
1 Jun 2021
Yang J Heckmann ND Nahhas CR Salzano MB Ruzich GP Jacobs JJ Paprosky WG Rosenberg AG Nam D

Aims. Recent total knee arthroplasty (TKA) designs have featured more anatomical morphologies and shorter tibial keels. However, several reports have raised concerns about the impact of these modifications on implant longevity. The aim of this study was to report the early performance of a modern, cemented TKA design. Methods. All patients who received a primary, cemented TKA between 2012 and 2017 with a minimum two-year follow-up were included. The implant investigated features an asymmetrical tibial baseplate and shortened keel. Patient demographic details, Knee Society Scores (KSS), component alignment, and the presence of radiolucent lines at final follow-up were recorded. Kaplan-Meier analyses were performed to estimate survivorship. Results. A total of 720 of 754 primary TKAs (95.5%) were included with a mean follow-up of 3.9 years (SD 1.3); 562 (78.1%) were cruciate-retaining and 158 (21.9%) were posterior-stabilized. A total of 11 (1.5%) required reoperation for periprosthetic joint infection and seven (1.0%) for aseptic tibial loosening (five cruciate-retaining, two posterior-stabilized). Loosening occurred at a mean of 3.3 years (0.9 to 6.5). There were no cases of loosening in the 33 patients who received a 14 mm × 30 mm tibial stem extension. All-cause survivorship was 96.6% at three years (95% confidence interval (CI) 95.3% to 98.0%) and 96.2% at five years (95% CI 94.8% to 97.7%). Survivorship with revision for aseptic loosening was 99.6% at three years (95% CI 99.1% to 100.0%) and 99.1% at five years (95% CI 98.4% to 99.9%). Tibial components were in significantly more varus in those with aseptic loosening (mean 3.4° (SD 3.7°) vs 1.3° (SD 2.0°); p = 0.015). There were no other differences in demographic, radiological, or surgical characteristics between revised and non-revised TKAs for aseptic loosening (p = 0.293 to 1.00). Mean KSS improved significantly from 57.3 (SD 9.5) preoperatively to 92.6 (SD 8.9) at the final follow-up (p < 0.001). Conclusion. This is the largest series to date of this design of implant. At short-term follow-up, the rate of aseptic tibial loosening is not overly concerning. Further observation is required to determine if there will be an abnormal rate of loosening at mid- to long-term follow-up. Cite this article: Bone Joint J 2021;103-B(6 Supple A):51–58


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 619 - 626
1 Apr 2021
Tolk JJ Janssen RPA Haanstra TM van der Steen MC Bierma-Zeinstra SMA Reijman M

Aims. Meeting preoperative expectations is known to be of major influence on postoperative satisfaction after total knee arthroplasty (TKA). Improved management of expectation, resulting in more realistic expectations can potentially lead to higher postoperative satisfaction. The objective of this study was to assess the effect of an additional preoperative education module, addressing realistic expectations for long-term functional recovery, on postoperative satisfaction and expectation fulfilment. Methods. In total, 204 primary TKA patients with osteoarthritis were enrolled in this randomized controlled trial (RCT). Patients were allocated to either usual preoperative education (control group) or usual education plus an additional module on realistic expectations (intervention group). Primary outcome was being very satisfied (numerical rating scale for satisfaction ≥ 8) with the treatment result at 12 months' follow-up. Other outcomes were change in preoperative expectations and postoperative expectation fulfilment. Results. A total of 187 patients (91.7%) were available for analysis at follow-up. In the intention-to-treat analysis, 58.5% (55/94) of patients were very satisfied with the treatment result in the control group, and 69.9% (65/93) of patients in the intervention group (adjusted odds ratio (AOR) 1.72, 95% confidence interval (CI) 0.90 to 3.29). A per-protocol analysis for patients who attended the education session (92.0%, n = 172) showed that 56.9% (49/86) of patients were very satisfied in the control group and 74.4% (61/86) in the intervention group (AOR 2.44, 95% CI 1.21 to 4.91). After preoperative education, the expectation scores in the intervention group were significantly lower (mean difference -6.9 (95% CI -10.2 to -3.6)) and did not alter in the control group (mean difference 0.5 (95% CI -2.9 to 3.9)). Overall, fulfilment of expectations at 12 months was significantly higher in the intervention group (mean difference 11.4% (95% CI 2.3 to 20.5)). Conclusion. Improved preoperative patient education can modify patient expectations, resulting in higher postoperative fulfilment of expectation and higher satisfaction in the group that attended the preoperative education. This is the first RCT to confirm the potential of improved expectation management on satisfaction after TKA. Cite this article: Bone Joint J 2021;103-B(4):619–626


Bone & Joint Open
Vol. 1, Issue 8 | Pages 465 - 473
1 Aug 2020
Aspinall SK Wheeler PC Godsiff SP Hignett SM Fong DTP

Aims. This study aims to evaluate a new home medical stretching device called the Self Treatment Assisted Knee (STAK) tool to treat knee arthrofibrosis. Methods. 35 patients post-major knee surgery with arthrofibrosis and mean range of movement (ROM) of 68° were recruited. Both the STAK intervention and control group received standard physiotherapy for eight weeks, with the intervention group additionally using the STAK at home. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Oxford Knee Scores (OKS) were collected at all timepoints. An acceptability and home exercise questionnaire capturing adherence was recorded after each of the interventions. Results. Compared to the control group, the STAK intervention group made significant gains in mean ROM (30° versus 8°, p < 0.0005), WOMAC (19 points versus 3, p < 0.0005), and OKS (8 points versus 3, p < 0.0005). The improvements in the STAK group were maintained at long-term follow-up. No patients suffered any complications relating to the STAK, and 96% of patients found the STAK tool ‘perfectly acceptable’. Conclusion. The STAK tool is effective in increasing ROM and reducing pain and stiffness. Patients find it acceptable and adherence to treatment was high. This study indicates that the STAK tool would be of benefit in clinical practice and may offer a new, cost-effective treatment for arthrofibrosis. Cite this article: Bone Joint Open 2020;1-8:465–473


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 148 - 157
1 Feb 2023
Koster LA Rassir R Kaptein BL Sierevelt IN Schager M Nelissen RGHH Nolte PA

Aims

The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs.

Methods

A total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 914 - 922
1 Dec 2023
Sang W Qiu H Xu Y Pan Y Ma J Zhu L

Aims

Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial.

Methods

The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 808 - 816
24 Oct 2023
Scott CEH Snowden GT Cawley W Bell KR MacDonald DJ Macpherson GJ Yapp LZ Clement ND

Aims

This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up.

Methods

From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims

The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design.

Methods

This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims

Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis).

Methods

Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 249 - 255
1 Mar 2024
Inclan PM Brophy RH Saccone NL Ma Y Pham V Yanik EL

Aims

The purpose of this study is to determine an individual’s age-specific prevalence of total knee arthroplasty (TKA) after cruciate ligament surgery, and to identify clinical and genetic risk factors associated with undergoing TKA.

Methods

This study was a retrospective case-control study using the UK Biobank to identify individuals reporting a history of cruciate ligament surgery. Data from verbal history and procedural codes recorded through the NHS were used to identify instances of TKA. Patient clinical and genetic data were used to identify risk factors for progression from cruciate ligament surgery to TKA. Individuals without a history of cruciate ligament reconstruction were used for comparison.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1416 - 1425
1 Dec 2024
Stroobant L Jacobs E Arnout N Van Onsem S Tampere T Burssens A Witvrouw E Victor J

Aims

Approximately 10% to 20% of knee arthroplasty patients are not satisfied with the result, while a clear indication for revision surgery might not be present. Therapeutic options for these patients, who often lack adequate quadriceps strength, are limited. Therefore, the primary aim of this study was to evaluate the clinical effect of a novel rehabilitation protocol that combines low-load resistance training (LL-RT) with blood flow restriction (BFR).

Methods

Between May 2022 and March 2024, we enrolled 45 dissatisfied knee arthroplasty patients who lacked any clear indication for revision to this prospective cohort study. All patients were at least six months post-surgery and had undergone conventional physiotherapy previously. The patients participated in a supervised LL-RT combined with BFR in 18 sessions. Primary assessments included the following patient-reported outcome measures (PROMs): Knee injury and Osteoarthritis Outcome Score (KOOS); Knee Society Score: satisfaction (KSSs); the EuroQol five-dimension five-level questionnaire (EQ-5D-5L); and the pain catastrophizing scale (PCS). Functionality was assessed using the six-minute walk Test (6MWT) and the 30-second chair stand test (30CST). Follow-up timepoints were at baseline, six weeks, three months, and six months after the start.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims

Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice.

Methods

This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m2 (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims

The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs).

Methods

All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1003 - 1012
8 Nov 2024
Gabr A Fontalis A Robinson J Hage W O'Leary S Spalding T Haddad FS

Aims

The aim of this study was to compare patient-reported outcomes (PROMs) following isolated anterior cruciate ligament reconstruction (ACLR), with those following ACLR and concomitant meniscal resection or repair.

Methods

We reviewed prospectively collected data from the UK National Ligament Registry for patients who underwent primary ACLR between January 2013 and December 2022. Patients were categorized into five groups: isolated ACLR, ACLR with medial meniscus (MM) repair, ACLR with MM resection, ACLR with lateral meniscus (LM) repair, and ACLR with LM resection. Linear regression analysis, with isolated ACLR as the reference, was performed after adjusting for confounders.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims

The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA).

Methods

A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years.


Aims

The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients.

Methods

A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1013 - 1019
11 Nov 2024
Clark SC Pan X Saris DBF Taunton MJ Krych AJ Hevesi M

Aims

Distal femoral osteotomies (DFOs) are commonly used for the correction of valgus deformities and lateral compartment osteoarthritis. However, the impact of a DFO on subsequent total knee arthroplasty (TKA) function remains a subject of debate. Therefore, the purpose of this study was to determine the effect of a unilateral DFO on subsequent TKA function in patients with bilateral TKAs, using the contralateral knee as a self-matched control group.

Methods

The inclusion criteria consisted of patients who underwent simultaneous or staged bilateral TKA after prior unilateral DFO between 1972 and 2023. The type of osteotomy performed, osteotomy hardware fixation, implanted TKA components, and revision rates were recorded. Postoperative outcomes including the Forgotten Joint Score-12 (FJS-12), Tegner Activity Scale score, and subjective knee preference were also obtained at final follow-up.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1123 - 1129
20 Dec 2024
Manara JR Nixon M Tippett B Pretty W Collopy D Clark GW

Aims

Unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) have both been shown to be effective treatments for osteoarthritis (OA) of the knee. Many studies have compared the outcomes of the two treatments, but less so with the use of robotics, or individualized TKA alignment techniques. Functional alignment (FA) is a novel technique for performing a TKA and shares many principles with UKA. Our aim was to compare outcomes from a case-matched series of robotic-assisted UKAs and robotic-assisted TKAs performed using FA.

Methods

From a prospectively collected database between April 2015 and December 2019, patients who underwent a robotic-assisted medial UKA (RA-UKA) were case-matched with patients who had undergone a FA robotic-assisted TKA (RA-TKA) during the same time period. Patients were matched for preoperative BMI, sex, age, and Forgotten Joint Score (FJS). A total of 101 matched pairs were eligible for final review. Postoperatively the groups were then compared for differences in patient-reported outcome measures (PROMs), range of motion (ROM), ability to ascend and descend stairs, and ability to kneel.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1177 - 1183
1 Nov 2023
van der Graaff SJA Reijman M Meuffels DE Koopmanschap MA

Aims

The aim of this study was to evaluate the cost-effectiveness of arthroscopic partial meniscectomy versus physical therapy plus optional delayed arthroscopic partial meniscectomy in young patients aged under 45 years with traumatic meniscal tears.

Methods

We conducted a multicentre, open-labelled, randomized controlled trial in patients aged 18 to 45 years, with a recent onset, traumatic, MRI-verified, isolated meniscal tear without knee osteoarthritis. Patients were randomized to arthroscopic partial meniscectomy or standardized physical therapy with an optional delayed arthroscopic partial meniscectomy after three months of follow-up. We performed a cost-utility analysis on the randomization groups to compare both treatments over a 24-month follow-up period. Cost utility was calculated as incremental costs per quality-adjusted life year (QALY) gained of arthroscopic partial meniscectomy compared to physical therapy. Calculations were performed from a healthcare system perspective and a societal perspective.


Bone & Joint Open
Vol. 4, Issue 9 | Pages 682 - 688
6 Sep 2023
Hampton M Balachandar V Charalambous CP Sutton PM

Aims

Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA.

Methods

A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years’ consultant experience in the NHS and fulfilling any one of the following criteria: a ‘high volume’ knee arthroplasty practice (> 150 TKAs per annum) as identified from the National joint Registry of England, Wales, Northern Ireland and the Isle of Man; a senior author of at least five peer reviewed articles related to TKA in the previous five years; a surgeon who is named trainer for a post-certificate of comletion of training fellowship in TKA.


Aims

The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness.

Methods

A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 277 - 283
1 Mar 2023
Gausden EB Puri S Chiu Y Figgie MP Sculco TP Westrich G Sculco PK Chalmers BP

Aims

The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution.

Methods

We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 240 - 248
1 Mar 2024
Kim SE Kwak J Ro DH Lee MC Han H

Aims

The aim of this study was to evaluate whether achieving medial joint opening, as measured by the change in the joint line convergence angle (∆JLCA), is a better predictor of clinical outcomes after high tibial osteotomy (HTO) compared with the mechanical axis deviation, and to find individualized targets for the redistribution of load that reflect bony alignment, joint laxity, and surgical technique.

Methods

This retrospective study analyzed 121 knees in 101 patients. Patient-reported outcome measures (PROMs) were collected preoperatively and one year postoperatively, and were analyzed according to the surgical technique (opening or closing wedge), postoperative mechanical axis deviation (deviations above and below 10% from the target), and achievement of medial joint opening (∆JLCA > 1°). Radiological parameters, including JLCA, mechanical axis deviation, and the difference in JLCA between preoperative standing and supine radiographs (JLCAPD), an indicator of medial soft-tissue laxity, were measured. Cut-off points for parameters related to achieving medial joint opening were calculated from receiver operating characteristic (ROC) curves.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1240 - 1248
1 Nov 2024
Smolle MA Keintzel M Staats K Böhler C Windhager R Koutp A Leithner A Donner S Reiner T Renkawitz T Sava M Hirschmann MT Sadoghi P

Aims

This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision.

Methods

A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims

This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults.

Methods

This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1579 - 1584
1 Dec 2018
Turgeon TR Gascoyne TC Laende EK Dunbar MJ Bohm ER Richardson CG

Aims. The introduction of a novel design of total knee arthroplasty (TKA) must achieve outcomes at least as good as existing designs. A novel design of TKA with a reducing radius of the femoral component and a modified cam-post articulation has been released and requires assessment of the fixation to bone. Radiostereometric analysis (RSA) of the components within the first two postoperative years has been shown to be predictive of medium- to long-term fixation. The aim of this study was to assess the stability of the tibial component of this system during this period of time using RSA. Patients and Methods. A cohort of 30 patients underwent primary, cemented TKA using the novel posterior stabilized fixed-bearing (ATTUNE) design. There was an even distribution of men and women (15:15). The mean age of the patients was 64 years (sd 8) at the time of surgery; their mean body mass index (BMI) was 35.4 kg/m2 (sd 7.9). RSA was used to assess the stability of the tibial component at 6, 12, and 24 months compared with a six-week baseline examination. Patient-reported outcome measures were also assessed. Results. The mean maximum total point motion (MTPM) of the tibial component between 12 and 24 months postoperatively was 0.08 mm (sd 0.08), which is well below the published threshold of 0.2 mm (p < 0.001). Patient-reported outcome measures consistently improved. Conclusion. The tibial component of this novel design of TKA showed stability between assessment 12 and 24 months postoperatively, suggesting an acceptably low risk of medium- to long-term failure due to aseptic loosening


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims

Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs.

Methods

A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m2 (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19).


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1313 - 1322
1 Dec 2022
Yapp LZ Clement ND Moran M Clarke JV Simpson AHRW Scott CEH

Aims

The aim of this study was to assess factors associated with the estimated lifetime risk of revision surgery after primary knee arthroplasty (KA).

Methods

All patients from the Scottish Arthroplasty Project dataset undergoing primary KA during the period 1 January 1998 to 31 December 2019 were included. The cumulative incidence function for revision and death was calculated up to 20 years. Adjusted analyses used cause-specific Cox regression modelling to determine the influence of patient factors. The lifetime risk was calculated as a percentage for patients aged between 45 and 99 years using multiple-decrement life table methodology.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 984 - 991
6 Nov 2024
Molloy T Gompels B McDonnell S

Aims

This Delphi study assessed the challenges of diagnosing soft-tissue knee injuries (STKIs) in acute settings among orthopaedic healthcare stakeholders.

Methods

This modified e-Delphi study consisted of three rounds and involved 32 orthopaedic healthcare stakeholders, including physiotherapists, emergency nurse practitioners, sports medicine physicians, radiologists, orthopaedic registrars, and orthopaedic consultants. The perceived importance of diagnostic components relevant to STKIs included patient and external risk factors, clinical signs and symptoms, special clinical tests, and diagnostic imaging methods. Each round required scoring and ranking various items on a ten-point Likert scale. The items were refined as each round progressed. The study produced rankings of perceived importance across the various diagnostic components.


Aims

Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear.

Methods

A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 880 - 887
1 Aug 2023
Onodera T Momma D Matsuoka M Kondo E Suzuki K Inoue M Higano M Iwasaki N

Aims

Implantation of ultra-purified alginate (UPAL) gel is safe and effective in animal osteochondral defect models. This study aimed to examine the applicability of UPAL gel implantation to acellular therapy in humans with cartilage injury.

Methods

A total of 12 patients (12 knees) with symptomatic, post-traumatic, full-thickness cartilage lesions (1.0 to 4.0 cm2) were included in this study. UPAL gel was implanted into chondral defects after performing bone marrow stimulation technique, and assessed for up to three years postoperatively. The primary outcomes were the feasibility and safety of the procedure. The secondary outcomes were self-assessed clinical scores, arthroscopic scores, tissue biopsies, and MRI-based estimations.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1265 - 1270
1 Dec 2023
Hurley ET Sherman SL Chahla J Gursoy S Alaia MJ Tanaka MJ Pace JL Jazrawi LM

Aims

The aim of this study was to establish consensus statements on medial patellofemoral ligament (MPFL) reconstruction, anteromedialization tibial tubercle osteotomy, trochleoplasty, and rehabilitation and return to sporting activity in patients with patellar instability, using the modified Delphi process.

Methods

This was the second part of a study dealing with these aspects of management in these patients. As in part I, a total of 60 surgeons from 11 countries contributed to the development of consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered unanimous.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1067 - 1073
1 Oct 2024
Lodge CJ Adlan A Nandra RS Kaur J Jeys L Stevenson JD

Aims

Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context.

Methods

A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 621 - 627
22 Aug 2023
Fishley WG Paice S Iqbal H Mowat S Kalson NS Reed M Partington P Petheram TG

Aims

The rate of day-case total knee arthroplasty (TKA) in the UK is currently approximately 0.5%. Reducing length of stay allows orthopaedic providers to improve efficiency, increase operative throughput, and tackle the rising demand for joint arthroplasty surgery and the COVID-19-related backlog. Here, we report safe delivery of day-case TKA in an NHS trust via inpatient wards with no additional resources.

Methods

Day-case TKAs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1059 - 1066
1 Oct 2024
Konishi T Hamai S Tsushima H Kawahara S Akasaki Y Yamate S Ayukawa S Nakashima Y

Aims

The Coronal Plane Alignment of the Knee (CPAK) classification has been developed to predict individual variations in inherent knee alignment. The impact of preoperative and postoperative CPAK classification phenotype on the postoperative clinical outcomes of total knee arthroplasty (TKA) remains elusive. This study aimed to examine the effect of postoperative CPAK classification phenotypes (I to IX), and their pre- to postoperative changes on patient-reported outcome measures (PROMs).

Methods

A questionnaire was administered to 340 patients (422 knees) who underwent primary TKA for osteoarthritis (OA) between September 2013 and June 2019. A total of 231 patients (284 knees) responded. The ­Knee Society Score 2011 (KSS 2011), Knee injury and Osteoarthritis Outcome Score-12 (KOOS-12), and Forgotten Joint Score-12 (FJS-12) were used to assess clinical outcomes. Using preoperative and postoperative anteroposterior full-leg radiographs, the arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) were calculated and classified based on the CPAK classification. To investigate the impact on PROMs, multivariable regression analyses using stepwise selection were conducted, considering factors such as age at surgery, time since surgery, BMI, sex, implant use, postoperative aHKA classification, JLO classification, and changes in aHKA and JLO classifications from preoperative to postoperative.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1286 - 1293
1 Dec 2023
Yang H Cheon J Jung D Seon J

Aims

Fungal periprosthetic joint infections (PJIs) are rare, but their diagnosis and treatment are highly challenging. The purpose of this study was to investigate the clinical outcomes of patients with fungal PJIs treated with two-stage exchange knee arthroplasty combined with prolonged antifungal therapy.

Methods

We reviewed our institutional joint arthroplasty database and identified 41 patients diagnosed with fungal PJIs and treated with two-stage exchange arthroplasty after primary total knee arthroplasty (TKA) between January 2001 and December 2020, and compared them with those who had non-fungal PJIs during the same period. After propensity score matching based on age, sex, BMI, American Society of Anesthesiologists grade, and Charlson Comorbidity Index, 40 patients in each group were successfully matched. The surgical and antimicrobial treatment, patient demographic and clinical characteristics, recurrent infections, survival rates, and relevant risk factors that affected joint survivorship were analyzed. We defined treatment success as a well-functioning arthroplasty without any signs of a PJI, and without antimicrobial suppression, at a minimum follow-up of two years from the time of reimplantation.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims

Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort.

Methods

Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 992 - 998
6 Nov 2024
Wignadasan W Magan A Kayani B Fontalis A Chambers A Rajput V Haddad FS

Aims

While residual fixed flexion deformity (FFD) in unicompartmental knee arthroplasty (UKA) has been associated with worse functional outcomes, limited evidence exists regarding FFD changes. The objective of this study was to quantify FFD changes in patients with medial unicompartmental knee arthritis undergoing UKA, and investigate any correlation with clinical outcomes.

Methods

This study included 136 patients undergoing robotic arm-assisted medial UKA between January 2018 and December 2022. The study included 75 males (55.1%) and 61 (44.9%) females, with a mean age of 67.1 years (45 to 90). Patients were divided into three study groups based on the degree of preoperative FFD: ≤ 5°, 5° to ≤ 10°, and > 10°. Intraoperative optical motion capture technology was used to assess pre- and postoperative FFD. Clinical FFD was measured pre- and postoperatively at six weeks and one year following surgery. Preoperative and one-year postoperative Oxford Knee Scores (OKS) were collected.


Aims

The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs).

Methods

A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


Bone & Joint Open
Vol. 4, Issue 3 | Pages 210 - 218
28 Mar 2023
Searle HKC Rahman A Desai AP Mellon SJ Murray DW

Aims

To assess the incidence of radiological lateral osteoarthritis (OA) at 15 years after medial unicompartmental knee arthroplasty (UKA) and assess the relationship of lateral OA with symptoms and patient characteristics.

Methods

Cemented Phase 3 medial Oxford UKA implanted by two surgeons since 1998 for the recommended indications were prospectively followed. A 15-year cumulative revision rate for lateral OA of 5% for this series was previously reported. A total of 163 unrevised knees with 15-year (SD 1) anterior-posterior knee radiographs were studied. Lateral joint space width (JSWL) was measured and severity of lateral OA was classified as: nil/mild, moderate, and severe. Preoperative and 15-year Oxford Knee Scores (OKS) and American Knee Society Scores were determined. The effect of age, sex, BMI, and intraoperative findings was analyzed. Statistical analysis included one-way analysis of variance and Kruskal-Wallis H test, with significance set at 5%.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 232 - 239
1 Mar 2024
Osmani HT Nicolaou N Anand S Gower J Metcalfe A McDonnell S

Aims

To identify unanswered questions about the prevention, diagnosis, treatment, and rehabilitation and delivery of care of first-time soft-tissue knee injuries (ligament injuries, patella dislocations, meniscal injuries, and articular cartilage) in children (aged 12 years and older) and adults.

Methods

The James Lind Alliance (JLA) methodology for Priority Setting Partnerships was followed. An initial survey invited patients and healthcare professionals from the UK to submit any uncertainties regarding soft-tissue knee injury prevention, diagnosis, treatment, and rehabilitation and delivery of care. Over 1,000 questions were received. From these, 74 questions (identifying common concerns) were formulated and checked against the best available evidence. An interim survey was then conducted and 27 questions were taken forward to the final workshop, held in January 2023, where they were discussed, ranked, and scored in multiple rounds of prioritization. This was conducted by healthcare professionals, patients, and carers.