Advertisement for orthosearch.org.uk
Results 1 - 100 of 2531
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1196 - 1201
1 Nov 2022
Anderson CG Brilliant ZR Jang SJ Sokrab R Mayman DJ Vigdorchik JM Sculco PK Jerabek SA

Aims. Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods. Methods. In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance. Results. Comparison of the mean postoperative femoral stem version measurements between CT and 3D hipEOS showed no significant difference (p = 0.862). In addition, the two version measurements were strongly correlated (r = 0.95; p < 0.001), and the mean paired difference in postoperative femoral version for CT scan and 3D biplanar radiography was -0.09° (95% confidence interval -1.09 to 0.91). Only three stem measurements (6.7%) were considered outliers with a > 5° difference. Conclusion. Our study supports the use of low-dose biplanar radiography for the postoperative assessment of femoral stem version after THA, demonstrating high correlation with CT. We found no significant difference for postoperative femoral version when comparing CT to 3D EOS. We believe 3D EOS is a reliable option to measure postoperative femoral version given its advantages of lower radiation dosage and shorter examination time. Cite this article: Bone Joint J 2022;104-B(11):1196–1201


Aims

Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance.

Methods

We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 726 - 732
16 Sep 2022
Hutchison A Bodger O Whelan R Russell ID Man W Williams P Bebbington A

Aims

We introduced a self-care pathway for minimally displaced distal radius fractures, which involved the patient being discharged from a Virtual Fracture Clinic (VFC) without a physical review and being provided with written instructions on how to remove their own cast or splint at home, plus advice on exercises and return to function.

Methods

All patients managed via this protocol between March and October 2020 were contacted by a medical secretary at a minimum of six months post-injury. The patients were asked to complete the Patient-Rated Wrist Evaluation (PRWE), a satisfaction questionnaire, advise if they had required surgery and/or contacted any health professional, and were also asked for any recommendations on how to improve the service. A review with a hand surgeon was organized if required, and a cost analysis was also conducted.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives. The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison. Methods. A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison. Results. The initial intraclass correlation (ICC) on the first 15 sets of radiographs was 0.67 (95% CI 0.63 to 0.71). However, the original description was being interpreted in different ways. After agreeing on the interpretation, the ICC on the second cohort improved to 0.75. The ICC improved even further to 0.79, when the baseline post-operative radiographs were available for comparison. Conclusion. This study demonstrates that the RUST scoring system is a reliable and repeatable outcome measure for assessing tibial fracture healing. Further improvement in the reliability of the scoring system can be obtained if the radiographs are compared with the baseline post-operative radiographs. Cite this article: Mr J.M. Leow. The radiographic union scale in tibial (RUST) fractures: Reliability of the outcome measure at an independent centre. Bone Joint Res 2016;5:116–121. DOI: 10.1302/2046-3758.54.2000628


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1327 - 1330
1 Oct 2006
Tokuhara Y Kadoya Y Kanekasu K Kondo M Kobayashi A Takaoka K

The shape of the flexion gap in 20 normal knees was evaluated by axial radiography of the distal femur, and the results compared with those obtained in a previous study by MRI. The observed asymmetry was reduced by 29% using radiography, with a mean value of 3.6° (1.5° to 6.3°) compared with that obtained by MRI of 5.1° (2.6° to 9.5°), a mean discrepancy of 1.49°. The results obtained by radiography and MRI showed a strong correlation (r = 0.78). Axial radiography is acceptable for the evaluation of the flexion gap and is less expensive and more comfortable to perform than MRI. Additionally, no metallic artefact occurs when the radiological method is used for assessment after arthroplasty


Bone & Joint Open
Vol. 2, Issue 10 | Pages 796 - 805
1 Oct 2021
Plumarom Y Wilkinson BG Willey MC An Q Marsh L Karam MD

Aims

The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing.

Methods

A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 485 - 489
1 Nov 1977
Simons G

A radiographic method is described for making the diagnosis of talo-navicular subluxation before ossification of the navicular bone occurs. Seven basic combinations of deformities are thought to occur in the club foot. Radiography before operation enables the surgeon to determine which of these combinations exists in a particular foot, and radiography during operation enables him to determine wheter or not all the existing deformities have been corrected, and therefore whether or not the operation must be extended


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1643 - 1646
1 Dec 2005
Miura H Matsuda S Okazaki K Kawano T Kawamura H Iwamoto Y

We have previously developed a radiographic technique, the oblique posterior condylar view, for assessment of the posterior aspect of the femoral condyles after total knee arthroplasty. The purpose of this study was to confirm the validity of this radiographic view based upon intra-operative findings at revision total knee arthroplasty. Lateral and oblique posterior condylar views were performed for 11 knees prior to revision total knee arthroplasty, and radiolucent lines or osteolysis of the posterior aspect of the femoral condyles were identified. These findings were compared with the intra-operative appearance of the posterior aspects of the femoral condyles. Statistical analysis showed that sensitivity and efficacy were significantly better for the oblique posterior condylar than the lateral view. This method can, therefore, be considered as suitable for routine follow-up radiographs of the femoral component and in the pre-operative planning of revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 608 - 609
1 Aug 1986
Gibson P Goodfellow J

The accurate assessment of compartmental involvement in degenerative arthritis of the knee is important when planning operative treatment. Standard radiographic techniques often fail to define the degree of involvement of the less affected tibiofemoral compartment. The use of stress radiography in the preoperative assessment of 30 knees with degenerative arthritis is described and the radiographic findings correlated with the changes found at arthrotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1128 - 1133
1 Nov 2003
Fukui N Nakagawa T Murakami S Hiraoka H Nakamura K

Axial radiographs were obtained under valgus and external rotation stress at 45° of knee flexion with and without contraction of the quadriceps muscle in order to assess the dynamics of patellar subluxation or dislocation. The radiography was performed on 82 knees in 61 patients with patellofemoral instability, and on 44 normal knees. The lateral patellofemoral angle and the congruence angle were measured and compared with the conventional Merchant views. Both parameters showed greater differences between symptomatic and normal knees on the stress radiographs obtained without quadriceps contraction. There was a major difference in the lateral patellofemoral angles between the groups, which clearly distinguished symptomatic knees from normal controls. Congruence angles on stress radiography had a significant correlation with the functional scores obtained after a period of conservative treatment and a positive correlation with the frequency of patellar subluxation. When the quadriceps contracted, two patterns of patellar shift were observed. While the patella reduced into the trochlear groove in all normal knees and about 70% of the symptomatic knees, contraction of the quadriceps caused further subluxation of the patella in the remaining symptomatic knees. All the knee joints which showed this displacement failed to respond to conservative treatment and eventually required surgical treatment. Thus, this technique of stress radiography is a simple, cost-effective and useful method of evaluating patellar instability and predicting the prognosis


Aims

The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury.

Methods

Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 987 - 992
1 Jul 2017
Shohat N Gilat R Shitrit R Smorgick Y Beer Y Agar G

Aims. To assess the long-term effect of distal trochanteric transfer (DTT) on the clinical and radiographic outcomes of patients with Legg-Calvé-Perthes’ disease (LCPD) following a varus derotational osteotomy (VDRO). Patients and Methods. For this single centre cross-sectional retrospective study we analysed the data of 22 patients (24 hips) with LCPD who had greater trochanteric overgrowth (GTO), following a VDRO performed in our institution between 1959 and 1983. GTO was defined as an articular trochanteric distance (ATD) of < 5 mm. We compared the radiographic and clinical outcomes of patients who underwent DTT for GTO (ten patients, ten hips) with those who did not (12 patients, 14 hips). Age at presentation was 6.9 years (4 to 10) and 8.0 years (3.2 to 12) respectively. Symptoms associated with the hip and general quality of life were assessed using the Harris hip score (HHS) and the Short Form (SF)-36 questionnaires. Results. At long-term follow-up of the DTT group, the ATD was 21.7 mm (standard deviation (. sd. ) 9.8) and the centro-trochanteric distance (CTD) was 13.8 mm (. sd. 8.3). In the control group the ATD was -0.6 mm (. sd. 7.8) and the CTD was 32.5 mm (. sd. 10.2). These differences were statistically significant (p < 0.001). The mean HHS and SF-36 scores were 68.4 (. sd. 25.0) and 62.0 (. sd. 27.7) for the DTT group and 73.2 (. sd. 24.2) and 73.3 (. sd. 21.5) for the control group, respectively. There was no statistically significant difference in the HHS (p = 0.63) or SF-36 score (p = 0.25). There were four patients who had undergone hip arthroplasty in the DTT group (40%) and one patient (7.1%) in the control group (p = 0.07). The mean age at the time of arthroplasty was 45.3 years (42.1 to 56.5) and 43.6 years respectively. Six patients in the DTT group suffered from moderate to severe osteoarthritis (Tönnis grade 2 or 3) compared with eight patients in the control group (60% versus 57.1%, p = 0.61). Conclusion. Although DTT improved the radiographic results in the long-term follow-up of patients with GTO following VDRO, there was no clinical benefit seen in the HHS, SF-36 or incidence of osteoarthritis compared with patients who had not undergone DTT. Cite this article: Bone Joint J 2017;99-B:987–92


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 598 - 601
1 Aug 1987
Bradley J Goodfellow J O'Connor J

After a unicompartmental Oxford knee replacement, a clear lateral radiographic view of the components may be obtained without the shadow of prosthetic components in the other compartment. Radiographs of 20 knees were studied; with the patient supine and the muscles relaxed, views with the knee at full extension and 90 degrees of flexion were obtained and the movement of the meniscal bearings over this range of flexion was measured. The bearings were found to move backwards on the tibia through an average distance of 4.4 mm (range 0.0 to 13.5 mm) in the medial compartment and 6.0 mm (range 1.6 to 13.0 mm) in the lateral compartment. These movements were in the same direction as that observed in cadaver specimens but smaller in magnitude. At 90 degrees of flexion, radiographs were obtained with the tibia twisted manually to the limits of medial and lateral rotation. The average movement of the bearings between these extremes was found to be 6.6 mm in the medial compartment and 5.1 mm in the lateral; their movements on the tibia were in opposite directions in the two compartments. Bearing movement was still present in knees examined five years after operation


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 457 - 460
1 May 1988
Richardson J Ramsay A Davidson J Kelly I

It is difficult to establish the diagnosis of an injured shoulder if only one radiographic projection is used. We have compared two lateral projections, the Neer trans-scapular and the apical oblique in 80 patients; the radiographs were presented randomly to 10 casualty officers and nine radiologists. The apical oblique view was found to permit more accurate diagnosis of fractures and of dislocation by both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1001 - 1004
1 Nov 1999
Takakura Y Tanaka Y Kumai T Sugimoto K

We studied the development of ball-and-socket deformity of the ankle by arthrography and radiography in 14 ankles of ten patients with congenital longitudinal deficiency of the fibula accompanied by various anomalies. The mean follow-up was for 18 years 10 months. In three ankles in infants less than one year old the lateral and medial sides of the ankle were already slightly round. In another seven ankles the ball-and-socket appearance developed before the age of five years. This was thought to be due to osseous coalition which limits eversion and inversion. In another four ankles in children who were over the age of one year at the initial examination, the deformity was demonstrated by arthrography and radiography at their first examination. Ball-and-socket deformity accompanied by tarsal coalition is an acquired deformity secondary to limitation of movement of the subtalar and midtarsal joints. It has completely developed by about five years of age


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1731 - 1735
1 Nov 2021
Iobst CA Frost MW Rölfing JD Rahbek O Bafor A Duncan M Kold S

Aims

Limb-lengthening nails have largely replaced external fixation in limb-lengthening and reconstructive surgery. However, the adverse events and high prevalence of radiological changes recently noted with the STRYDE lengthening nail have raised concerns about the use of internal lengthening nails. The aim of this study was to compare the prevalence of radiological bone abnormalities between STRYDE, PRECICE, and FITBONE nails prior to nail removal.

Methods

This was a retrospective case series from three centres. Patients were included if they had either of the three limb-lengthening nails (STYDE, PRECICE, or FITBONE) removed. Standard orthogonal radiographs immediately prior to nail removal were examined for bone abnormalities at the junction of the telescoping nail parts.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 696 - 698
1 Aug 1989
Backer M Kofoed H

We compared goniometric assessment of passive ankle movement with radiographic measurements in 100 normal ankles. Significant differences were recorded in both dorsiflexion and plantarflexion; clinical measurements overestimated the range of movement. For scientific documentation of tibiotalar mobility, radiographic measurements should be used


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 957 - 962
1 Jul 2015
Yamazaki H Uchiyama S Komatsu M Hashimoto S Kobayashi Y Sakurai T Kato H

There is no consensus on the benefit of arthroscopically assisted reduction of the articular surface combined with fixation using a volar locking plate for the treatment of intra-articular distal radial fractures. In this study we compared the functional and radiographic outcomes of fluoroscopically and arthroscopically guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral unstable intra-articular distal radial fractures were randomised equally into the two groups for treatment. The mean age of these 74 patients was 64 years (24 to 92). We compared functional outcomes including active range of movement of the wrist, grip strength and Disabilities of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic outcomes that included gap, step, radial inclination, volar angulation and ulnar variance. . There were no significant differences between the techniques with regard to functional outcomes or radiographic parameters. The mean gap and step in the fluoroscopic and arthroscopic groups were comparable at 0.9 mm (standard deviation. (sd). 0.7) and 0.7 mm (. sd. 0.7) and 0.6 mm (. sd. 0.6) and 0.4 mm (. sd. 0.5), respectively; p = 0.18 and p = 0.35). . Arthroscopic reduction conferred no advantage over conventional fluoroscopic guidance in achieving anatomical reduction of intra-articular distal radial fractures when using a volar locking plate. Cite this article: Bone Joint J 2015; 97-B:957–62


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 399 - 404
1 Aug 1982
Brunton F Wilkinson J Wise K Simonis R

A series of 75 patients who had undergone anterior cervical fusion between 1965 and 1977 were reviewed. The patients were divided into two groups: those in Group A had had the level of fusion indicated by cine radiography, whereas in Group B the level had been determined by plain radiographs and clinical symptoms and signs. Results showed that cine radiography was the more accurate diagnostic technique. Accurate diagnosis of the level to be fused, the careful clinical selection of patients and sound bony union were found to be vital to the success of anterior cervical fusion. The incidence of pseudarthrosis was significant in single-level fusions and was even greater in double-level fusions and in patients with a history of trauma, especially whiplash injuries. It was rare to develop recurrence of symptoms in adjacent levels after fusion of a level localised by cine radiography


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 164 - 168
1 May 1976
Benson M Evans D

The medial displacement osteotomy of Chiari has an established place in the management of older children and adults with severe hip dysplasia. The results claimed for the operation are, however, variable. There have also been reports of sciatic nerve lesions. In this study ten cadavers were operated upon. Chiari osteotomy was performed upon five, and five acted as controls. The hemipelvis was removed from each cadaver; each specimen was deep-frozen and sectioned transversely. The distance of the sciatic nerve from the nearest bony point was measured in each section and the results were recorded graphically. A further radiographic and photographic study was performed to determine whether apparent displacement at the osteotomy might be misleading. The conclusion was drawn that the sciatic nerve is angulated at the osteotomy and further endangered by the risk of bone splintering at the sciatic notch. The radiographic study suggested that some poor clinical results may be explained by a radiological artefact, because there is a tendency for the osteotomy to hinge posteriorly at the sciatic notch opening anteriorly like a book. Radiographs may suggest excellent medial displacement whereas in fact the femoral head is very poorly covered


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 233 - 239
1 Mar 1993
Hoffman E Crosier J Cremin B

We compared the usefulness of radiography, CT and MRI in 25 children with spinal tuberculosis. Radiography provided most of the information necessary for diagnosis and treatment. Axial CT was the most accurate method for visualising the posterior bony elements. Sagittal MRI best showed the severity and content of extradural compression and helped to differentiate between an abscess and fibrous tissue. The main value of CT and MRI is in the preoperative evaluation of the small proportion of patients who require surgical treatment for paraplegia


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 132 - 137
1 Feb 1981
Gregg P Walder D

A group of patients were studied 10 years after stopping work in a high-pressure environment. Radiographs of their long bones showed little change during the period, but only two of 12 scintigrams were normal. The 10 abnormal scintigrams contained 18 "hot-spots" which were not always associated with an abnormal radiographic appearance; the findings suggest that some lesions may never become visible on a radiograph. A reactive or repair process associated with these lesions may be prolonged and may not be beneficial, as structural failure of the joint may subsequently occur. Prognosis should therefore be guarded


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 188 - 194
1 Feb 2014
Gilbody J Taylor C Bartlett GE Whitehouse SL Hubble MJW Timperley AJ Howell JR Wilson MJ

Impaction bone grafting for the reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. Between 1995 and 2001 we used this technique in acetabular reconstruction, in combination with a cemented component, in 304 hips in 292 patients revised for aseptic loosening. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of ten years after the index operation. Mean follow-up was 12.4 years (. sd. 1.5) (10.0 to 16.0). Kaplan–Meier survival with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared radiologically loose. . Cite this article: Bone Joint J 2014;96-B:188–94


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 3 | Pages 301 - 305
1 Aug 1979
Wynne-Davies R Scott J

A radiographic suvey has been carried out of 147 first-degree relatives of forty-seven patients treated in Edinburgh for spondylolisthesis of the fifth lumbar vertebra; twelve patients had the dysplastic (congenital) type and thirty-five an isthmic defect. The survey identified 19 per cent of relatives with spondylolysis, and index patients with each type of spondylolisthesis had relatives with the opposite type. Index patients with the dysplastic form had a higher proportion of affected relatives (33 per cent) than had those with the isthmic type (15 per cent), but both figures were significantly in excess of the estimated frequency for the general population of under 1 per cent and 5 per cent respectively. Spina bifida occulta at the fifth lumbar or first sacral level or both, and lumbosacral segmental defects were commoner amongst all individuals with spondylolysis than amongst unaffected relatives (dysplastic form 94 per cent, isthmic type 32 per cent, unaffected relatives 7 per cent). However, there was no single instance of a neural tube defect (anencephaly, spina bifida with or without meningocele, other generalised vertebral anomalies or spinal dysraphism) amongst 826 first-, second- or third-degree relatives. It is concluded that the developmental defects of the vertebrae associated with spondylolysis are not aetiologically related to the neural tube defects. The one in three risk of spondylolysis to near relatives of patients with the dysplastic form of spondylolisthesis is emphasised in order that the deformity in their sibs and children can be recognised at any early age


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 715 - 720
1 Sep 1991
Cooke T Scudamore R Bryant J Sorbie C Siu D Fisher B

A method is described which provides standardised reproducible radiographic images of the lower limb. Anteroposterior and lateral radiographs are digitised and processed by computer to provide graphic/numeric displays of angles and linear measurements, relating the centre points of the hip, knee, and ankle. Two cases illustrate how surgical planning is facilitated when standardised data are available. These data confirm the close relationship between postoperative limb alignment and positioning of prosthetic elements


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 676 - 678
1 Jul 1991
Thomsen N Overgaard S Olsen L Hansen H Nielsen S

We recorded inter- and intra-observer variations in the classification of ankle fractures by the Lauge Hansen and Weber systems. Radiographs of 94 patients were classified independently by four observers. The observer variation was calculated by kappa statistics, which corrects the obtained values for the agreement expected by chance. There was an acceptable level of agreement for the overall classification into both systems. For the staging of supination-adduction and supination-eversion fractures in the Lauge Hansen system the agreement was poor. The results indicate that future classification systems should be subject to reliability analysis before they are accepted


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 509 - 512
1 Aug 1984
Deacon P Flood B Dickson R

Eleven articulated scoliotic spines were examined radiographically and morphometrically. Measurement of the curve on anteroposterior radiographs of the specimens gave a mean Cobb angle of 70 degrees, though true anteroposterior radiographs of the deformity revealed a mean Cobb angle of 99 degrees (41% greater). Lateral radiographs gave the erroneous impression that there was a mean kyphosis of 41 degrees while true lateral projections revealed a mean apical lordosis of 14 degrees. Morphometric measurements confirmed the presence of a lordosis at bony level, the apical vertebral bodies being significantly taller anteriorly (P less than 0.02). There were significant correlations (P less than 0.01) between the true size of the lateral scoliosis, the amount of axial rotation and the size of the apical lordosis. This study illustrates the three-dimensional nature of the deformity in scoliosis and its property of changing in character and magnitude according to the plane of radiographic projection


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 385 - 389
1 May 1992
Barrack R Mulroy R Harris W

To assess the effect of improved methods of femoral cementing on the loosening rates in young patients, we reviewed 50 'second-generation' cemented hip arthroplasties in 44 patients aged 50 years or less. The femoral stems were all collared and rectangular in cross-section with rounded corners. The cement was delivered by a gun into a medullary canal occluded distally with a cement plug. A clinical and radiographic review was undertaken at an average of 12 years (10 to 14.8) and no patient was lost to follow-up. No femoral component was revised for aseptic loosening, and only one stem was definitely loose by radiographic criteria. By contrast, 11 patients had undergone revision for symptomatic aseptic loosening of the acetabular component and 11 more had radiographic signs of acetabular loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 3 | Pages 349 - 351
1 Aug 1977
Specht E

A computerised image analyser has been used experimentally to determine its possible usefulness in quantifying bone density. Rats were prepared for this purpose and ash weight/volume readings were obtained on femora which had been radiographed and studied to estimate radiographic density by means of the image analyser. The findings indicated that rats can be prepared by administering oestradiol or by allowing an additional week's growth, both of which give a statistically significant increase of bone density. The computerised image analyser was able to detect these differences but the correlations, although real and linear, between ash weight/volume and radiographic density were not large. Further refinements in techniques will be needed before the system is applied clinically


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 684 - 688
1 Jul 1998
Haraguchi N Kato F Hayashi H

We report two new radiographic projections for evaluating avulsion fractures at the lateral malleolus. We used seven freshly amputated legs with simulated avulsion fractures and radiopaque markers to assess their value. The projections allow accurate assessment of the displacement of fragments without superimposition, and also show whether they affect the anterior talofibular or the calcaneofibular ligament or both


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 56 - 60
1 Jan 1996
Ishii T Miyagawa S Fukubayashi T Hayashi K

We investigated a new method of stress radiography of the subtalar joints using forced maximum dorsiflexion of the ankle in a supinated position. We measured transposition of the lateral process of the talus at the posterior subtalar joint in lateral views of normal amputated ankles, normal control subjects and patients with recurrent ankle sprains. The mean displacement in the control groups (n = 36) was 29.9%, significantly different from the 43.0% in patients with recurrent ankle sprains (n = 24). In the amputated specimens with intact ligaments movement was similar to that in normal subjects. Section of the calcaneofibular and the interosseous ligaments allowed much the same movement as in patients with recurrent ankle sprains. The new method is simple and useful for detecting subtalar instability


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 228 - 232
1 Apr 1982
Pearcy M Burrough S

Assessment of bony union after anterior fusion of the lumbar spine has previously relied on the skilled interpretation of plain radiograph. A biplanar radiographic technique was used to measure small movements between vertebrae and to give a quantitative measure of bony union in 11 patients who had undergone interbody fusion with autogenous bone chips at one level in the lumbar spine. The investigation gave three types of results: bony union, where the fused level showed marked restriction of movement relative to the rest of the lumbar spine; paradoxical movement, where the fused joint showed marked reverse movement (when the patient flexed, the fused level of the lumbar spine extended) which was thought to be due to an anterior bony bar which caused an altered pattern of movement; and non-union, where the level of fusion showed no restriction of movement. The intervertebral joint above the level of fusion was shown to move more than the other joints in the lumbar spine. The study showed that bony union is possible with the use of autogenous cancellous bone chips, and that biplanar radiographic technique can determine the extent of union


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 770 - 774
1 Nov 1986
Mjoberg B Selvik G Hansson L Rosenqvist R Onnerfalt R

Twenty patients were examined by standard radiography and roentgen stereophotogrammetric analysis (RSA) during a two-year period after total hip arthroplasty. Eleven of the acetabular components migrated cranially and three femoral components migrated distally. This migration was most rapid during the first four months after operation. Our findings support the possibility that mechanical loosening is initiated by thermal injury during polymerisation of the cement; the less frequent migration of the metallic femoral component compared with the polyethylene acetabular component may be because the metal acts as a heat sink. Standard radiographs were inadequate for assessment of early mechanical loosening, whereas RSA could reveal migration within four months of the arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 61 - 65
1 Jan 1993
Tiel-van Buul M van Beek E Broekhuizen A Bakker A Bos K van Royen E

Radiographs of the scaphoid after injury are difficult to interpret, and bone scintigraphy is widely used to increase the accuracy of diagnosis, though many fractures suspected on scintigraphy cannot be confirmed radiologically. We have reviewed the clinical consequences, after one year, of managing suspected scaphoid fractures according to the bone-scan results. We studied 160 patients, 35 of whom had initially positive radiographs and were treated in a cast for 12 weeks. The other 125 had bone scintigraphy and were managed according to the result. After a minimum of one year 119 patients were reviewed. Scintigraphically suspected scaphoid fracture could not be confirmed radiologically in 25%. There were no cases of nonunion. The long period of immobilisation in patients with positive radiographs or positive bone scans did not influence the frequency or severity of late symptoms compared with those with a normal bone scan


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 365 - 373
1 May 1987
Hogh J Macnicol M

We have reviewed a series of 94 Chiari pelvic osteotomies carried out from 1966 to 1982. In 83 hips the indication for surgery had been pain, and of these patients 73 (88%) had appreciable relief within one year of operation. The other 11 hips were all in children and were painless; in them the osteotomy had successfully stabilised progressive subluxation of the hip. At review after a mean follow-up of 10 years (range, 2 to 18 years) 68 previously painful hips were reassessed. Although function of the hips had deteriorated slowly with time, four of the seven cases with 18 years' follow-up had good function and only minor symptoms. A detailed analysis of the radiographic changes produced by the Chiari osteotomy was made, using computerised analysis of variance. The beneficial effects of the osteotomy resulted from complex changes, among which the provision of a stable fulcrum for the hip seemed to be the most important


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 705 - 713
1 Jul 2004
Bhat M McCarthy M Davis TRC Oni JA Dawson S

We treated 50 patients with fractures of the waist of the scaphoid in a below-elbow plaster cast for up to 13 weeks. Displacement of the fragments was assessed independently by two observers using MRI and radiographs performed within two weeks of injury. The MRI assessments showed that only the measurement of sagittal translation of the fragments and an overall assessment of displacement had satisfactory inter- and intra-observer reproducibility and revealed that nine of the 50 fractures were displaced. Only three of the 49 fractures with adequate follow-up failed to unite, and all were displaced with more than 1 mm of translation in the sagittal plane. If the MRI assessment of displacement of the fracture was used as the measurement of choice, assessment of displacement on the initial scaphoid series of radiographs showed a sensitivity of between 33% and 47% and a positive predictive value of between 27% and 86%. Neither observer was able correctly to identify more than 33% to 47% of the displaced fractures from the plain radiographs. Although the overall assessment of displacement and gapping and translation in the coronal plane on the plain radiographs influenced the rate of union, none of these parameters identified all three fractures which failed to unite. We conclude that the assessment of displacement of scaphoid fractures on MRI can probably be used to assess the likelihood of union although the small number of nonunions limits the power of the study. In contrast, the assessment of displacement on routine radiography is inaccurate and of less value in predicting union


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 428 - 432
1 Aug 1983
Vegter J van den Broek J

A diastasis between the femoral head and the acetabulum can be achieved for a short while by the application of manual traction on the lower extremity. The intra-articular low-pressure area can be visualised radiographically and is known as a "vacuum phenomenon". The resulting arthrogram clearly outlines the shape, thickness and extent of the cartilage. In the presence of an effusion the diastasis occurs without a vacuum phenomenon. This simple, non-invasive and inoffensive method of traction radiography will not only show abnormalities of the cartilage but also demonstrate the presence or absence of an effusion of the hip


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1069 - 1073
1 Aug 2016
Stirling E Jeffery J Johnson N Dias J

Aims

The degree of displacement of a fracture of the distal radius is an important factor which can be assessed using simple radiographic measurements. Our aim was to investigate the reliability and reproducibility of these measurements and to determine if they should be used clinically.

Patients and Methods

A 10% sample was randomly generated from 3670 consecutive adult patients who had presented to University Hospitals of Leicester NHS Trust between 2007 and 2010 with a fracture of the distal radius. Radiographs of the 367 patients were assessed by two independent reviewers. Four measurements of displacement of the fracture were recorded and the inter-observer correlation assessed using the intra-class correlation coefficient.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 302 - 304
1 Mar 1988
Bobyn J Engh C Glassman A

Threaded acetabular components are widely used in cementless total hip replacement, despite a poor understanding of the nature of the bone-implant interface. We have examined one case in which the threaded titanium ring appeared to be well incorporated with no discernible radiolucency. Microradiography and histology surprisingly showed that the threads were entirely encapsulated in fibrous tissue. This raises doubt about the relevance of plain radiography to the analysis of the acetabular interface


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 225 - 230
1 Mar 1990
Staubli H Jakob R

We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress radiography under anaesthesia. The gravity sign and the posterior drawer test in near extension and its passive reduction were diagnostic in 20 of the 24 knees, and the active reduction of posterior subluxation was diagnostic in 18. The reversed pivot shift sign helped to diagnose severe posterior and posterolateral subluxations, but the external rotation recurvatum test was negative in all 24 knees. Stress radiography in near extension revealed a highly significant increase in posterior tibial subluxation in the injured knees


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 757 - 760
1 Sep 1990
Mulroy R Harris W

Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only three femoral components had definitely loosened, none were probably loose and 24 were graded as possibly loose. In contrast, the incidence of radiographic loosening on the acetabular side was 42%. Improved cementing techniques have produced a marked reduction in the rate of aseptic loosening of the femoral component, but the incidence of acetabular loosening is unchanged


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 358 - 364
1 May 1993
Eyres K Bell M Kanis J

We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and radiography. Whereas new bone was detected by both DEXA and ultrasonography within 1 to 2 weeks of distraction, it was not visible on the radiographs until 4 to 8 weeks. Limb alignment and gap measurement were accurately assessed by DEXA without the need for standard radiographs or scanograms. With ultrasound the distraction gap appeared as an echolucent window which narrowed progressively producing a hyper-reflecting line after which further consolidation could not be assessed. As measured by DEXA the density of the new bone at this stage was approximately 45% of control values and did not represent normal cortication. Whereas ultrasound could be used to identify defects in mineralisation and to determine when to dynamise the fixator system, DEXA could measure the quantity and rate of formation of bone throughout lengthening


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 458 - 464
1 Apr 2017
Abrahams JM Kim YS Callary SA De Ieso C Costi K Howie DW Solomon LB

Aims

This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria.

Patients and Methods

Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 235 - 239
1 Mar 1994
Nilsson L Frazen H Carlsson A Onnerfalt R

We made a study of 49 total hip arthroplasties at five years, comparing the Charnley hip score, the Nottingham Health Profile (NHP) score and the appearance on serial radiographs. Each of the three investigations was performed by an independent observer with no knowledge of the results of the other two studies. The eight patients with radiographic signs of prosthetic loosening had significant reductions in function and quality of life as measured by the NHP questionnaire, but no differences in the mean Charnley hip scores. None of the eight patients had clinical signs of prosthetic loosening sufficient to recommend revision of their THR. The NHP is a relatively low-cost method of providing long-term follow-up of THR


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 462 - 463
1 Apr 2000
SUTHERLAND AG BAKER AR


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 632 - 635
1 Jul 1999
Davies AP Calder DA Marshall T Glasgow MMS

We took posteroanterior weight-bearing radiographs, both with the joint fully extended and in 30° of flexion, in a consecutive series of 50 knees in 37 patients referred for the primary assessment of pain and/or stiffness. These radiographs were reported ‘blind’ both by an orthopaedic surgeon and a radiologist. Direct measurement of the joint space, together with grading of the severity of erosion according to the Ahlback criteria, was undertaken. Any other abnormality present was also documented.

The radiographs of the knees in 30° of flexion consistently showed more advanced erosion in both the medial (p = 0.001) and the lateral (p = 0.0001) tibiofemoral compartments, when compared with those of knees in full extension. The Ahlback classification of 25 joints was altered, in some cases by several grades, by the flexed position of the joint. In every case in which another abnormality was identified on the radiograph in full extension, it was also noted on that of the knee in 30° of flexion. In a further four cases, additional pathology could only be seen in the flexed knee. Every patient was able to complete the radiological examination without difficulty. Our study supports the adoption of a weight-bearing view in 30° of flexion as the standard posteroanterior radiograph for the assessment of tibiofemoral osteoarthritis in patients over 50 years of age.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 338 - 338
1 Mar 1987
Horsfield D Jones S


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 136 - 141
1 Jan 2010
Franken M Grimm B Heyligers I

We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value.

Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p < 0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 279 - 285
1 Feb 2013
Engesæter IØ Laborie LB Lehmann TG Fevang JM Lie SA Engesæter LB Rosendahl K

In Norway total joint replacement after hip dysplasia is reported more commonly than in neighbouring countries, implying a higher prevalence of the condition. We report on the prevalence of radiological features associated with hip dysplasia in a population of 2081 19-year-old Norwegians. The radiological measurements used to define hip dysplasia were Wiberg’s centre-edge (CE) angle at thresholds of < 20° and < 25°, femoral head extrusion index <  75%, Sharp’s angle > 45°, an acetabular depth to width ratio < 250 and the sourcil shape assessed subjectively. The whole cohort underwent clinical examination of their range of hip movement, body mass index (BMI), and Beighton hypermobility score, and were asked to complete the EuroQol (EQ-5D) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). The prevalence of hip dysplasia in the cohort varied from 1.7% to 20% depending on the radiological marker used. A Wiberg’s CE angle <  20° was seen in 3.3% of the cohort: 4.3% in women and 2.4% in men. We found no association between subjects with multiple radiological signs indicative of dysplasia and BMI, Beighton score, EQ-5D or WOMAC. Although there appears to be a high prevalence of hip dysplasia among 19-year-old Norwegians, this is dependent on the radiological parameters applied.

Cite this article: Bone Joint J 2013;95-B:279–85.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 570 - 575
1 Jul 1997
Boniforti FG Fujii G Angliss RD Benson MKD

We have evaluated the reliability of the measurement of radiological indicators in developmental dysplasia of the hip. Three observers each independently assessed 60 pelvic radiographs from infants aged from 3 to 36 months. Errors from the true value of a single measurement made by a single observer (E1), of the average of two measurements by a single observer (E2), and of the average of two single measurements by two different observers (E3) were established for the acetabular index of Hilgenreiner, for the assessment of superior and lateral femoral displacement and for indicators of pelvic alignment.

The errors for the assessment of the acetabular index were E1 ± 5°, E2 ± 5°, and E3 ± 3.5°. There was a significant correlation between the presence of an acetabular notch on the radiograph and an increased error in measurement (p = 0.01). Yamamuro’s measurement of lateral femoral displacement was more reliable than the Hilgenreiner distance. The errors of indicators of pelvic alignment showed a correlation with the age of the infant; the quotient of pelvic rotation was more reliable after seven months of age (p < 0.0001). The errors of the measurement of the symphysis os-ischium angle tended to increase with age and those of the measurement of the index of pelvic tilt decreased with skeletal maturation (p = 0.002).


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 535 - 539
1 Jul 1996
Roolker W Tiel-van Buul MMC Bossuyt PMM Bakker AJ Bos KE Marti RK Broekhuizen AH

We have assessed the value of using a simple apparatus, the Carpal Box, in patients with suspected scaphoid fracture, to produce elongated and magnified radiographs of the carpus. The interobserver agreement between 60 observers of standard scaphoid radiographs and longitudinal and transverse Carpal Box radiographs (X-CB) was compared in 11 patients. Three-phase bone scanning was used as a comparative standard. If at least 75% of the observers agreed and the result was confirmed by three-phase bone scanning, the outcome was termed reliable.

Scaphoid radiographs and the longitudinal X-CB films were reliable in four patients and the transverse X-CB films in six patients. The bone scan suggested a scaphoid fracture in five of the 11 patients.

Agreement in the interpretation of the standard scaphoid radiographs was acceptable in only 36% of patients: in interpretation of transverse Carpal Box radiographs this figure increased to 55%.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 534 - 537
1 Jul 1993
Harada T Ebara S Anwar M Kajiura I Oshita S Hiroshima K Ono K

Some radiological features of the lumbar spine of 84 patients with spastic diplegia were compared with 50 control subjects. The average age of the patients was 20.1 years (3 to 39). Spondylolysis of the fifth lumbar vertebra was found in 21%, four times more frequently than in normal subjects. No patient under nine years of age had spondylolysis and the frequency increased with age. The average angle of lumbar lordosis in spastic patients in the standing position was greater than in normal subjects, and increased with age. The patients had a decreased sacrofemoral angle which caused an increase in Ferguson's angle and explained the increased angle of lumbar lordosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 963 - 964
1 Nov 1996
Krettek C Blauth M Miclau T Rudolf J Könemann B Schandelmaier P

The accuracy of templates used for the preoperative planning of the fixation of intramedullary fractures depends on radiological magnification. To study the accuracy of these templates, we randomly selected 100 femoral and 100 tibial radiographs taken after stabilisation by an intramedullary nail using a standard technique. We then compared the known nail length with the corresponding measurements on the radiographs.

The mean magnification factor for the femur was 9% and for the tibia 7%; these differ considerably from the range of magnification of the manufacturers’ templates (femur, 15% to 17%; tibia 10% to 15%). We conclude that templates are unreliable for the selection of implant length and that this should be done by intraoperative measurements.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 28 - 32
1 Jan 1992
Rubin P Leyvraz P Aubaniac J Argenson J Esteve P de Roguin B

Biological fixation of cementless femoral implants requires primary stability by optimal fit in the proximal femur. The anatomy of the bone must then be known precisely. We analysed in vitro the accuracy of bone measurements of 32 femurs and compared the dimensions obtained from radiographs and CT scans with the true anatomical dimensions. Standard radiographs gave only a rough approximation of femoral geometry (mean difference: 2.4 +/- 1.4 mm) insufficiently accurate to allow selection of the best fitting prosthesis from a range of sizes and altogether inadequate to design a custom-made prosthesis. CT scans give greater accuracy (mean difference: 0.8 +/- 0.7 mm) in our experimental conditions, but in clinical practice additional sources of error exist.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 259 - 263
1 Mar 1989
Cruickshank J Koike M Dickson R

We have developed a simple technique for demonstrating the sagittal profile of each rotated level of a scoliotic spine and used it to determine the patterns of lordosis and kyphosis in each of six clinical types of idiopathic scoliosis. The currently accepted classification of scoliosis is inaccurate and a modification is proposed. The three main types of scoliosis were shown to have sagittal profiles distinctly different from each other and from normal. Single structural curves had short lordotic sections at their apices, limited above and below by kyphosis. Double curves showed longer lordotic sections limited only by one area of kyphosis. Lordosis throughout the thoracic and lumbar spine was associated with triple curve patterns. The biomechanical effects of the abnormal sagittal profiles provide a simple explanation for the genesis and progression of the different types of scoliosis, and the recognition of the pattern of the sagittal abnormalities permits treatment to be designed on a sound anatomical basis for individual cases.



The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 279 - 286
1 Feb 2014
Gardner ROE Bradley CS Howard A Narayanan UG Wedge JH Kelley SP

The incidence of clinically significant avascular necrosis (AVN) following medial open reduction of the dislocated hip in children with developmental dysplasia of the hip (DDH) remains unknown. We performed a systematic review of the literature to identify all clinical studies reporting the results of medial open reduction surgery. A total of 14 papers reporting 734 hips met the inclusion criteria. The mean follow-up was 10.9 years (2 to 28). The rate of clinically significant AVN (types 2 to 4) was 20% (149/734). From these papers 221 hips in 174 children had sufficient information to permit more detailed analysis. The rate of AVN increased with the length of follow-up to 24% at skeletal maturity, with type 2 AVN predominating in hips after five years’ follow-up. The presence of AVN resulted in a higher incidence of an unsatisfactory outcome at skeletal maturity (55% vs 20% in hips with no AVN; p < 0.001). A higher rate of AVN was identified when surgery was performed in children aged < 12 months, and when hips were immobilised in ≥ 60°of abduction post-operatively. Multivariate analysis showed that younger age at operation, need for further surgery and post-operative hip abduction of ≥ 60° increased the risk of the development of clinically significant AVN.

Cite this article: Bone Joint J 2014;96-B:279–86.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 240 - 244
1 Mar 1994
Alsema R Deutman R Mulder T

In 1988 we reported a ten-year review of 83 surviving patients from a group of 135 (146 prostheses) who had undergone primary hip replacement using the Stanmore prosthesis. We have now reviewed 44 of these patients at 15 to 16 years. Four patients had undergone revision, but the other 40 were all satisfied with the result of their hip replacement, 36 having little or no pain. Functional activities had decreased, but were still adequate for their average age of 81 years. There had been definite migration of the cup and/or femoral component in three hips, wear of the cup in ten and resorption of the calcar in six. Of the 24 hips inserted with radiopaque cement, eight showed an increase in radiolucent lines at the acetabular interface. The cumulative survival rate of the prosthesis was 91% at 15 to 16 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 435 - 442
1 Nov 1979
Sikorski J Peters J Watt I

A new radiological technique is presented in which serial axial radiographs of the patellofemoral joints are taken under conditions in which the muscles about the knee and hip are contracted in a manner similar to that during weight-bearing. A form of analysis has been developed whereby patellar rotation can be measured in two planes and femoral rotation about its long axis inferred. A population of asymptomatic adults and children was investigated in this way and their results (regarded as normal) compared with those in fifteen children with idiopathic chondromalacia patellae. In the normal child the femur rotates medially with the onset of muscle activity; by contrast the children with chondromalacia show a reversal of this mechanism.


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 2 | Pages 273 - 273
1 May 1950
Burrows HJ


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 367 - 372
1 May 1988
Samuelson K Freeman M Levack B Rassmussen G Revell P

Thirty-seven patients with extensive acetabular defects due to loose implants had revisions with uncemented components, the acetabulum being augmented with homograft bone. In six of these, a histological study of graft incorporation was made. At a mean follow-up of 1.5 years 34 patients were free of pain and 35 could walk for 30 minutes or longer. No graft had obviously sequestrated. Two components had radiological evidence of migration but remain asymptomatic. We conclude that cementless revision surgery with homograft supplementation of the acetabulum is clinically successful in the short-term. The long-term outcome is unknown.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 4 | Pages 567 - 568
1 Nov 1981
Skirving A


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 186 - 188
1 Mar 1989
Chen S Badrinath K Pell L Mitchell K

We aimed to find out whether the Hastings bipolar prosthesis moved in a bipolar fashion after its use for displaced fractures of the femoral neck. In 65 patients non-weight-bearing movement was assessed radiographically and compared with an earlier study of the Monk prosthesis. In 70% of patients, the only movement was between the acetabulum and the prosthetic shell, the prosthesis behaving as if it were unipolar. This did not change with time, but there was a slight improvement in the range of movement, particularly in flexion. The absence of movement between the outer shell and the metal head is most probably due to the design of the prosthesis and makes this prosthesis unsuitable for use in osteoarthritic hips.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 214 - 221
1 May 1980
Gregg P Walder D

The early diagnosis of caisson disease of bone is hindered by the long delay which must elapse before an abnormality becomes apparent on a radiograph. The possible use of bone scintigraphy for this purpose was investigated. Necrosis of the bone and marrow was produced in rabbits by glass microspheres to simulate persistent gas-bubble emboli and then serial radiographs and scintigrams using 99mTc-diphosphonate were obtained. Regions of necrosis could be detected as "hot-spots" on the scintigrams as early as three weeks after the causative insult, which was many weeks before any abnormality could be detected on the radiographs. Histological examination of excised femora suggested that the scintigraphic abnormality might depend on the new bone formation during a reactive or repair process. It is suggested that scintigraphy may have clinical value in caisson disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 747 - 747
1 Jul 1999
Brueton RN


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 412 - 417
1 May 1990
Kim Y

In 44 consecutive patients, 60 porous-coated anatomic total knee (PCA) prostheses with a porous-coated central tibial stem were implanted without using cement. The clinical results and bony remodelling have been assessed after five years' follow-up. The average Hospital for Special Surgery knee score was 33.1 before operation and 95.7 at the latest follow-up, while the average range of movement improved from 63 degrees to 123 degrees. No subsidence or migration of the components was seen. A radiodense line appeared around the components at six months to one year after the operation and became more dense with time. There was no evidence of bone resorption related to stress-shielding in the tibial plateau.


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 3 | Pages 513 - 513
1 Aug 1953
Golding FC



Bone & Joint Research
Vol. 12, Issue 5 | Pages 313 - 320
8 May 2023
Saiki Y Kabata T Ojima T Kajino Y Kubo N Tsuchiya H

Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements. Results. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R. 2. of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3° fixed error in the extension position, compared to radiography. Conclusion. OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner’s skills. Cite this article: Bone Joint Res 2023;12(5):313–320


Bone & Joint 360
Vol. 13, Issue 2 | Pages 41 - 44
1 Apr 2024

The April 2024 Children’s orthopaedics Roundup. 360. looks at: Ultrasonography or radiography for suspected paediatric distal forearm fractures?; Implant density in scoliosis: an important variable?; Gait after paediatric femoral shaft fracture treated with intramedullary nail fixation: a longitudinal prospective study; The opioid dilemma: navigating pain management for children’s bone fractures; 12- to 20-year follow-up of Dega acetabuloplasty in patients with developmental dysplasia of the hip; Physeal fractures of the distal ulna: incidence and risk factors for premature growth arrest; Analysis of growth after transphyseal anterior cruciate ligament reconstruction in children; Management of lateral condyle humeral fracture associated with elbow dislocation in children: a retrospective international multicentre cohort study


Bone & Joint 360
Vol. 12, Issue 5 | Pages 34 - 36
1 Oct 2023

The October 2023 Spine Roundup. 360. looks at: Cutting through surgical smoke: the science of cleaner air in spinal operations; Unlocking success: key factors in thoracic spine decompression and fusion for ossification of the posterior longitudinal ligament; Deep learning algorithm for identifying cervical cord compression due to degenerative canal stenosis on radiography; Surgeon experience influences robotics learning curve for minimally invasive lumbar fusion; Decision-making algorithm for the surgical treatment of degenerative lumbar spondylolisthesis of L4/L5; Response to preoperative steroid injections predicts surgical outcomes in patients undergoing fusion for isthmic spondylolisthesis


Bone & Joint 360
Vol. 13, Issue 1 | Pages 41 - 43
1 Feb 2024

The February 2024 Research Roundup. 360. looks at: If you use a surgical helmet, you should seal your gown-glove interface; The use of iodophor-impregnated drapes in patients with iodine-related allergies: a case series and review of the literature; Location of the ovaries in children and efficacy of gonadal shielding in hip and pelvis radiography; Prehospital tranexamic acid administration does not improve outcomes in severe trauma patients; Silver-coated distal femur megaprosthesis in chronic infections with severe bone loss: a multicentre case series


Bone & Joint Open
Vol. 5, Issue 2 | Pages 117 - 122
9 Feb 2024
Chaturvedi A Russell H Farrugia M Roger M Putti A Jenkins PJ Feltbower S

Aims. Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial radiography typically results in multiple follow-up attendances to clinic, radiation exposure, and delays return to work. Suboptimal management can result in significant disability and, frequently, litigation. Methods. We present a service evaluation report following the introduction of a quality-improvement themed, streamlined, clinical scaphoid pathway. Patients are offered a removable wrist splint with verbal and written instructions to remove it two weeks following injury, for self-assessment. The persistence of pain is the patient’s guide to ‘opt-in’ and to self-refer for a follow-up appointment with a senior emergency physician. On confirmation of ongoing signs of clinical scaphoid injury, an urgent outpatient ‘fast’-wrist protocol MRI scan is ordered, with instructions to maintain wrist immobilization. Patients with positive scan results are referred for specialist orthopaedic assessment via a virtual fracture clinic. Results. From February 2018 to January 2019, there were 442 patients diagnosed as clinical scaphoid fractures. 122 patients (28%) self-referred back to the emergency department at two weeks. Following clinical review, 53 patients were discharged; MRI was booked for 69 patients (16%). Overall, six patients (< 2% of total; 10% of those scanned) had positive scans for a scaphoid fracture. There were no known missed fractures, long-term non-unions or malunions resulting from this pathway. Costs were saved by avoiding face-to-face clinical review and MRI scanning. Conclusion. A patient-focused opt-in approach is safe and effective to managing the suspected occult (clinical) scaphoid fracture. Cite this article: Bone Jt Open 2024;5(2):117–122



Aims. Osteochondral lesions of the talus (OLT) are a common cause of disability and chronic ankle pain. Many operative treatment strategies have been introduced; however, they have their own disadvantages. Recently lesion repair using autologous cartilage chip has emerged therefore we investigated the efficacy of particulated autologous cartilage transplantation (PACT) in OLT. Methods. We retrospectively analyzed 32 consecutive symptomatic patients with OLT who underwent PACT with minimum one-year follow-up. Standard preoperative radiography and MRI were performed for all patients. Follow-up second-look arthroscopy or MRI was performed with patient consent approximately one-year postoperatively. Magnetic resonance Observation of Cartilage Repair Tissue (MOCART) score and International Cartilage Repair Society (ICRS) grades were used to evaluate the quality of the regenerated cartilage. Clinical outcomes were assessed using the pain visual analogue scale (VAS), Foot Function Index (FFI), and Foot Ankle Outcome Scale (FAOS). Results. All patients had ICRS grade IV cartilage lesions, except for one (ICRS grade III). The paired MOCART scores significantly improved from 42.5 (SD 1.53) to 63.5 (SD 22.60) (p = 0.025) in ten patients. Seven patients agreed to undergo second-look arthroscopy; 5 patients had grade I (normal) ICRS scores and two patients had grade II (nearly normal) ICRS scores. VAS, FFI, and all subscales of FAOS were significantly improved postoperatively (p ≤ 0.003). Conclusion. PACT significantly improved the clinical, radiological, and morphological outcomes of OLT. We consider this to be a safe and effective surgical method based on the short-term clinical results of this study. Cite this article: Bone Jt Open 2023;4(12):942–947


Bone & Joint Research
Vol. 11, Issue 7 | Pages 465 - 476
13 Jul 2022
Li MCM Chow SK Wong RMY Chen B Cheng JCY Qin L Cheung W

Aims. There is an increasing concern of osteoporotic fractures in the ageing population. Low-magnitude high-frequency vibration (LMHFV) was shown to significantly enhance osteoporotic fracture healing through alteration of osteocyte lacuno-canalicular network (LCN). Dentin matrix protein 1 (DMP1) in osteocytes is known to be responsible for maintaining the LCN and mineralization. This study aimed to investigate the role of osteocyte-specific DMP1 during osteoporotic fracture healing augmented by LMHFV. Methods. A metaphyseal fracture was created in the distal femur of ovariectomy-induced osteoporotic Sprague Dawley rats. Rats were randomized to five different groups: 1) DMP1 knockdown (KD), 2) DMP1 KD + vibration (VT), 3) Scramble + VT, 4) VT, and 5) control (CT), where KD was performed by injection of short hairpin RNA (shRNA) into marrow cavity; vibration treatment was conducted at 35 Hz, 0.3 g; 20 minutes/day, five days/week). Assessments included radiography, micro-CT, dynamic histomorphometry and immunohistochemistry on DMP1, sclerostin, E11, and fibroblast growth factor 23 (FGF23). In vitro, murine long bone osteocyte-Y4 (MLO-Y4) osteocyte-like cells were randomized as in vivo groupings. DMP1 KD was performed by transfecting cells with shRNA plasmid. Assessments included immunocytochemistry on osteocyte-specific markers as above, and mineralized nodule staining. Results. Healing capacities in DMP1 KD groups were impaired. Results showed that DMP1 KD significantly abolished vibration-enhanced fracture healing at week 6. DMP1 KD significantly altered the expression of osteocyte-specific markers. The lower mineralization rate in DMP1 KD groups indicated that DMP1 knockdown was associated with poor fracture healing process. Conclusion. The blockage of DMP1 would impair healing outcomes and negate LMHFV-induced enhancement on fracture healing. These findings reveal the importance of DMP1 in response to the mechanical signal during osteoporotic fracture healing. Cite this article: Bone Joint Res 2022;11(7):465–476


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims. The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance. Methods. A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated. Results. The mean follow-up was six years (2 to 14). PRNR started after a mean of 7.5 weeks (SD 2.1) and progressed significantly during the first two years, by the end of which the bone resorption stabilized. PRNR was detected in 81% (n = 45) of patients in Group 1 and 88% (n = 36) in Group 2. The final mean PRNR was 3.0 mm (SD 2.3) in Group 1 and 3.7 mm (SD 2.5) in Group 2. The mean MEPS, QuickDASH, and pASES-E were 95.9 (SD 11.5), 4.4 (SD 9.2), and 94.8 (SD 10.9) in Group 1 and 92.2 (SD 16.2), 9.9 (SD 21.5), and 90.8 (SD 15) in Group 2, respectively. No significant differences were observed between groups in the clinical and radiological outcomes. No correlations were found between PRNR and the clinical results. Conclusion. PRNR after press-fit RHA is a common radiological finding that develops in the first 24 months before stabilizing definitively. PRNR does not affect the clinical results or implant survival in the mid term. Cite this article: Bone Joint J 2023;105-B(8):905–911


Bone & Joint Open
Vol. 5, Issue 6 | Pages 524 - 531
24 Jun 2024
Woldeyesus TA Gjertsen J Dalen I Meling T Behzadi M Harboe K Djuv A

Aims. To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. Methods. A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1). Results. We included 120 fractures in 119 patients. Compared to radiographs, CT increased the sensitivity of detecting unstable trochanteric fractures from 63% to 70% (p = 0.028) and from 70% to 76% (p = 0.004) using AO/OTA and EVJ, respectively. Compared to radiographs alone, CT increased the sensitivity of detecting a large posterolateral trochanter major fragment or a comminuted trochanter major fragment from 63% to 76% (p = 0.002) and from 38% to 55% (p < 0.001), respectively. CT improved intra-rater reliability for stability assessment using EVJ (AC1 0.68 to 0.78; p = 0.049) and for detecting a large posterolateral trochanter major fragment (AC1 0.42 to 0.57; p = 0.031). Conclusion. A preoperative CT of trochanteric fractures increased detection of unstable fractures using the AO/OTA and EVJ classification systems. Compared to radiographs, CT improved intra-rater reliability when assessing fracture stability and detecting large posterolateral trochanter major fragments. Cite this article: Bone Jt Open 2024;5(6):524–531


Bone & Joint Open
Vol. 3, Issue 6 | Pages 502 - 509
20 Jun 2022
James HK Griffin J Pattison GTR

Aims. To identify a core outcome set of postoperative radiographic measurements to assess technical skill in ankle fracture open reduction internal fixation (ORIF), and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. An e-Delphi exercise was undertaken at a major trauma centre (n = 39) to identify relevant parameters. Feasibility was tested by two authors. Reliability and validity was tested using postoperative radiographs of ankle fracture operations performed by trainees enrolled in an educational trial (IRCTN 20431944). To determine construct validity, trainees were divided into novice (performed < ten cases at baseline) and intermediate groups (performed ≥ ten cases at baseline). To assess concurrent validity, the procedure-based assessment (PBA) was considered the gold standard. The inter-rater and intrarater reliability was tested using a randomly selected subset of 25 cases. Results. Overall, 235 ankle ORIFs were performed by 24 postgraduate year three to five trainees during ten months at nine NHS hospitals in England, UK. Overall, 42 PBAs were completed. The e-Delphi panel identified five ‘final product analysis’ parameters and defined acceptability thresholds: medial clear space (MCS); medial malleolar displacement (MMD); lateral malleolar displacement (LMD); tibiofibular clear space (TFCS) (all in mm); and talocrural angle (TCA) in degrees. Face validity, content validity, and feasibility were excellent. PBA global rating scale scores in this population showed excellent construct validity as continuous (p < 0.001) and categorical (p = 0.001) variables. Concurrent validity of all metrics was poor against PBA score. Intrarater reliability was substantial for all parameters (intraclass correlation coefficient (ICC) > 0.8), and inter-rater reliability was substantial for LMD, MMD, TCA, and moderate (ICC 0.61 to 0.80) for MCS and TFCS. Assessment was time efficient compared to PBA. Conclusion. Assessment of technical skill in ankle fracture surgery using the first postoperative radiograph satisfies the tested Van der Vleuten’s utility criteria for effective assessment. 'Final product analysis' assessment may be useful to assess skill transfer in the simulation-based research setting. Cite this article: Bone Jt Open 2022;3(6):502–509


Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims. Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade. Methods. Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims. Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. Methods. This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC). Results. Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. Conclusion. We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis. Cite this article: Bone Jt Open 2023;4(1):3–12


Bone & Joint Research
Vol. 12, Issue 10 | Pages 657 - 666
17 Oct 2023
Sung J Barratt KR Pederson SM Chenu C Reichert I Atkins GJ Anderson PH Smitham PJ

Aims. Impaired fracture repair in patients with type 2 diabetes mellitus (T2DM) is not fully understood. In this study, we aimed to characterize the local changes in gene expression (GE) associated with diabetic fracture. We used an unbiased approach to compare GE in the fracture callus of Zucker diabetic fatty (ZDF) rats relative to wild-type (WT) littermates at three weeks following femoral osteotomy. Methods. Zucker rats, WT and homozygous for leptin receptor mutation (ZDF), were fed a moderately high-fat diet to induce T2DM only in the ZDF animals. At ten weeks of age, open femoral fractures were simulated using a unilateral osteotomy stabilized with an external fixator. At three weeks post-surgery, the fractured femur from each animal was retrieved for analysis. Callus formation and the extent of healing were assessed by radiograph and histology. Bone tissue was processed for total RNA extraction and messenger RNA (mRNA) sequencing (mRNA-Seq). Results. Radiographs and histology demonstrated impaired fracture healing in ZDF rats with incomplete bony bridge formation and an influx of intramedullary inflammatory tissue. In comparison, near-complete bridging between cortices was observed in Sham WT animals. Of 13,160 genes, mRNA-Seq analysis identified 13 that were differentially expressed in ZDF rat callus, using a false discovery rate (FDR) threshold of 10%. Seven genes were upregulated with high confidence (FDR = 0.05) in ZDF fracture callus, most with known roles in inflammation. Conclusion. These findings suggest that elevated or prolonged inflammation contributes to delayed fracture healing in T2DM. The identified genes may be used as biomarkers to monitor and treat delayed fracture healing in diabetic patients. Cite this article: Bone Joint Res 2023;12(10):657–666


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. Methods. We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification. Results. A total of seven stems (4.2%) were revised during the study period: one for aseptic loosening, three for periprosthetic fracture, two for infection, and one for recurrent dislocation. At 20 years, survival with revision of the stem for any indication and for aseptic loosening as the endpoint was 96.0% (95% confidence interval (CI) 92.6 to 99.5) and 98.4% (95% CI 96.2 to 100), respectively. At 25 years, the corresponding rates of survival were 94.5% (95% CI 89.9 to 99.3) and 98.1% (95% CI 95.7 to 99.6), respectively. There was radiological evidence of stable bony fixation in 86 stems (76.1%) and evidence of loosening in four (3.5%) at 20 years. All patients with radiological evidence of loosening were asymptomatic. Conclusion. The Omnifit HA femoral stem offered promising long-term survival into the third decade. Cite this article: Bone Joint J 2024;106-B(3 Supple A):110–114


Bone & Joint Open
Vol. 5, Issue 1 | Pages 28 - 36
18 Jan 2024
Selmene MA Moreau PE Zaraa M Upex P Jouffroy P Riouallon G

Aims. Post-traumatic periprosthetic acetabular fractures are rare but serious. Few studies carried out on small cohorts have reported them in the literature. The aim of this work is to describe the specific characteristics of post-traumatic periprosthetic acetabular fractures, and the outcome of their surgical treatment in terms of function and complications. Methods. Patients with this type of fracture were identified retrospectively over a period of six years (January 2016 to December 2021). The following data were collected: demographic characteristics, date of insertion of the prosthesis, details of the intervention, date of the trauma, characteristics of the fracture, and type of treatment. Functional results were assessed with the Harris Hip Score (HHS). Data concerning complications of treatment were collected. Results. Our series included 20 patients, with a mean age of 77 years (46 to 90). All the patients had at least one comorbid condition. Radiographs showed that 75% of the fractures were pure transverse fractures, and a transverse component was present in 90% of patients. All our patients underwent surgical treatment: open reduction and internal fixation, revision of the acetabular component, or both. Mean follow-up was 24 months, and HHS at last follow-up was 75.5 (42 to 95). The principal complications observed were dislocations of the prosthesis (30%) and infections (20%). A need for revision surgery was noted in 30% of patients. No dislocation occurred in patients undergoing osteosynthesis with acetabular reconstruction. We did not note either mechanical loosening of the acetabular component nor thromboembolic complications. In all, 30% of patients presented acute anemia requiring transfusion, and one death was reported. Conclusion. Post-traumatic periprosthetic acetabular fractures frequently have a transverse component that can destabilize the acetabular implant. The frequency of complications, principally dislocations, led to a high rate of revision surgery. Improvements in preoperative planning should make it possible to codify management to reduce this high rate of complications. The best results were obtained when the surgical strategy combined osteosynthesis with acetabular reconstruction. Cite this article: Bone Jt Open 2024;5(1):28–36


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 17 - 24
1 May 2024
Anderson LA Wylie JD Kapron C Blackburn BE Erickson JA Peters CL

Aims. Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular procedures such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary cohort of patients, who underwent PAO in isolation without any intra-articular procedures. Methods. From June 2012 to March 2022, 349 rectus-sparing PAOs were performed and followed for a minimum of one year (mean 6.2 years (1 to 11)). The mean age was 24 years (14 to 46) and 88.8% were female (n = 310). Patients were evaluated at final follow-up for patient-reported outcome measures (PROMs). Clinical records were reviewed for complications or subsequent surgery. Radiographs were reviewed for the following acetabular parameters: lateral centre-edge angle, anterior centre-edge angle, acetabular index, and the alpha-angle (AA). Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics were used to analyze risk factors for HA. Results. A total of 16 hips (15 patients; 4.6%) underwent subsequent HA with labral repair and femoral osteochondroplasty, the most common interventions. For those with a minimum of two years of follow-up, 5.3% (n = 14) underwent subsequent HA. No hips underwent total hip arthroplasty and one revision PAO was performed. Overall, 17 hips (4.9%) experienced a complication and 99 (26.9%) underwent hardware removal. All PROMs improved significantly postoperatively. Radiologically, 80% of hips (n = 279) reached the goal for acetabular correction (77% for acetbular index and 93% for LCEA), with no significant differences between those who underwent subsequent HA and those who did not. Conclusion. Rectus-sparing PAO is associated with a low rate of subsequent HA for intra-articular pathology at a mean of 6.2 years’ follow-up (1 to 11). Acetabular correction alone may be sufficient as the primary intervention for the majority of patients with symptomatic acetabular dysplasia. Cite this article: Bone Joint J 2024;106-B(5 Supple B):17–24


Bone & Joint Open
Vol. 4, Issue 5 | Pages 306 - 314
3 May 2023
Rilby K Mohaddes M Kärrholm J

Aims. Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. Methods. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years. Results. At two and five years, more patients considered the hip with the CLS femoral component as superior but without a statistically significant difference. There were no differences in clinical outcome, magnitude of femoral component migration, or change of bone mineral density at five years. At three months, the Fitmore femoral component had subsided a median -0.71 mm (interquartile range (IQR) -1.67 to -0.20) and the CLS femoral component -0.70 mm (IQR -1.53 to -0.17; p = 0.742). In both groups the femoral head centre had migrated posteriorly (Fitmore -0.17 mm (IQR -0.98 to -0.04) and CLS -0.23 mm (IQR -0.87 to 0.07; p = 0.936)). After three months neither of the femoral components showed much further migration. During the first postoperative year, one Fitmore femoral component was revised due to aseptic loosening. Conclusion. Up to five years, we found no statistically significant difference in outcomes between the Fitmore and the CLS femoral components. The slightly worse outcomes, including one revised hip because of loosening, speaks against the hypothesis that the Fitmore femoral component should be advantageous compared to the CLS if more patients had been recruited to this study. Cite this article: Bone Jt Open 2023;4(5):306–314


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 89 - 97
1 May 2024
Scholz J Perka C Hipfl C

Aims. There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. Methods. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75). Results. DM bearings were used significantly more frequently in elderly patients (p = 0.003) and in hips with abductor deficiency (p < 0.001). The re-dislocation rate was 13.2% for DM bearings compared with 17.9% for standard bearings, and 22.2% for constrained liners (p = 0.432). Re-revision-free survival for DM bearings was 84% (95% confidence interval (CI) 0.77 to 0.91) compared with 74% (95% CI 0.67 to 0.81) for standard articulations, and 67% (95% CI 0.51 to 0.82) for constrained liners (p = 0.361). Younger age (hazard ratio (HR) 0.92 (95% CI 0.85 to 0.99); p = 0.031), lower comorbidity (HR 0.44 (95% CI 0.20 to 0.95); p = 0.037), smaller heads (HR 0.80 (95% CI 0.64 to 0.99); p = 0.046), and retention of the acetabular component (HR 8.26 (95% CI 1.37 to 49.96); p = 0.022) were significantly associated with re-dislocation. All DM bearings which re-dislocated were in patients with abductor muscle deficiency (HR 48.34 (95% CI 0.03 to 7,737.98); p = 0.303). The radiological analysis did not reveal a significant relationship between restoration of the geometry of the hip and re-dislocation. The mean mHHSs significantly improved from 43 points (0 to 88) to 67 points (20 to 91; p < 0.001) at the final follow-up, with no differences between the types of bearing. Conclusion. We found that the use of DM bearings reduced the rates of re-dislocation and re-revision in revision THA for recurrent dislocation, but did not guarantee stability. Abductor deficiency is an important predictor of persistent instability. Cite this article: Bone Joint J 2024;106-B(5 Supple B):89–97


Bone & Joint Research
Vol. 11, Issue 2 | Pages 49 - 60
1 Feb 2022
Li J Wong RMY Chung YL Leung SSY Chow SK Ip M Cheung W

Aims. With the ageing population, fragility fractures have become one of the most common conditions. The objective of this study was to investigate whether microbiological outcomes and fracture-healing in osteoporotic bone is worse than normal bone with fracture-related infection (FRI). Methods. A total of 120 six-month-old Sprague-Dawley (SD) rats were randomized to six groups: Sham, sham + infection (Sham-Inf), sham with infection + antibiotics (Sham-Inf-A), ovariectomized (OVX), OVX + infection (OVX-Inf), and OVX + infection + antibiotics (OVX-Inf-A). Open femoral diaphysis fractures with Kirschner wire fixation were performed. Staphylococcus aureus at 4 × 10. 4. colony-forming units (CFU)/ml was inoculated. Rats were euthanized at four and eight weeks post-surgery. Radiography, micro-CT, haematoxylin-eosin, mechanical testing, immunohistochemistry (IHC), gram staining, agar plating, crystal violet staining, and scanning electron microscopy were performed. Results. Agar plating analysis revealed a higher bacterial load in bone (p = 0.002), and gram staining showed higher cortical bone colonization (p = 0.039) in OVX-Inf compared to Sham-Inf. OVX-Inf showed significantly increased callus area (p = 0.013), but decreased high-density bone volume (p = 0.023) compared to Sham-Inf. IHC staining showed a significantly increased expression of TNF-α in OVX-Inf compared to OVX (p = 0.049). Significantly reduced bacterial load on bone (p = 0.001), enhanced ultimate load (p = 0.001), and energy to failure were observed in Sham-Inf-A compared to Sham-Inf (p = 0.028), but not in OVX-Inf-A compared to OVX-Inf. Conclusion. In osteoporotic bone with FRI, infection was more severe with more bone lysis and higher bacterial load, and fracture-healing was further delayed. Systemic antibiotics significantly reduced bacterial load and enhanced callus quality and strength in normal bone with FRI, but not in osteoporotic bone. Cite this article: Bone Joint Res 2022;11(2):49–60


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims. This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes. Methods. Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence. Results. In all, 500 patients reached six-month follow-up, 420 reached one-year follow-up, and 188 reached two-year follow-up. The mean age was 67.8 years (23.9 to 88.5). A total of 38 patients (7.5%) presented with inflammatory arthritis. A total of 101 (20.0%) of implantations used patient-specific instrumentation; 167 patients (33.1%) underwent an additional procedure at the time of surgery. A total of seven patients died of unrelated causes, two withdrew, and one was lost to follow-up. The mean follow-up was 16.2 months (6 to 36). There was a significant improvement from baseline across all functional outcome scores at six months, one, and two years. There was no significant difference in outcomes with the use of patient-specific instrumentation, type of arthritis, or COFAS type. Five (1.0%) implants were revised. The overall complication rate was 8.8%. The non-revision reoperation rate was 1.4%. The 30-day readmission rate was 1.2% and the one-year mortality 0.74%. Conclusion. The early experience and complications reported in this study support the current use of the INFINITY TAA as a safe and effective implant in the treatment of end-stage ankle arthritis. Cite this article: Bone Joint J 2021;103-B(7):1270–1276


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 78 - 83
1 Jul 2021
Roedel GG Kildow BJ Sveom DS Garvin KL

Aims. Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Methods. Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis. Results. Clinical outcomes showed significant improvement of mean Harris Hip Scores from 52.8 (SD 13.5) preoperatively to 94.8 (SD 7.6) postoperatively. One hip was revised for recurrent instability, and there were no infections. No hips were revised for mechanical loosening or osteolysis. Mean polyethylene linear wear was 0.04 mm/year and volumetric wear was 6.22 mm. 3. /year, with no significant differences between head size or material. Osteolysis was not present in any of the hips. Conclusion. The use of HXLPE in THA for patients aged 50 years and younger has performed exceptionally well without evidence of significant wear causing mechanical loosening or necessitating revision. The radiolucent lines of the acetabular component must be followed to determine the prognostic significance. This investigation represents the longest clinical follow-up of a large, consecutive cohort of patients aged 50 years or younger with THA using HXLPE. This long-term analysis found negligible polyethylene wear, no incidence of aseptic loosening, and excellent clinical outcomes at and beyond 15 years of follow-up. Cite this article: Bone Joint J 2021;103-B(7 Supple B):78–83


Bone & Joint Research
Vol. 10, Issue 12 | Pages 767 - 779
8 Dec 2021
Li Y Yang Y Wang M Zhang X Bai S Lu X Li Y Waldorff EI Zhang N Lee WY Li G

Aims. Distraction osteogenesis (DO) is a useful orthopaedic procedure employed to lengthen and reshape bones by stimulating bone formation through controlled slow stretching force. Despite its promising applications, difficulties are still encountered. Our previous study demonstrated that pulsed electromagnetic field (PEMF) treatment significantly enhances bone mineralization and neovascularization, suggesting its potential application. The current study compared a new, high slew rate (HSR) PEMF signal, with different treatment durations, with the standard Food and Drug Administration (FDA)-approved signal, to determine if HSR PEMF is a better alternative for bone formation augmentation. Methods. The effects of a HSR PEMF signal with three daily treatment durations (0.5, one, and three hours/day) were investigated in an established rat DO model with comparison of an FDA-approved classic signal (three hrs/day). PEMF treatments were applied to the rats daily for 35 days, starting from the distraction phase until termination. Radiography, micro-CT (μCT), biomechanical tests, and histological examinations were employed to evaluate the quality of bone formation. Results. All rats tolerated the treatment well and no obvious adverse effects were found. By comparison, the HSR signal (three hrs/day) treatment group achieved the best healing outcome, in that endochondral ossification and bone consolidation were enhanced. In addition, HSR signal treatment (one one hr/day) had similar effects to treatment using the classic signal (three three hrs/day), indicating that treatment duration could be significantly shortened with the HSR signal. Conclusion. HSR signal may significantly enhance bone formation and shorten daily treatment duration in DO, making it a potential candidate for a new clinical protocol for patients undergoing DO treatments. Cite this article: Bone Joint Res 2021;10(12):767–779


Bone & Joint Research
Vol. 10, Issue 3 | Pages 156 - 165
1 Mar 2021
Yagi H Kihara S Mittwede PN Maher PL Rothenberg AC Falcione ADCM Chen A Urish KL Tuan RS Alexander PG

Aims. Periprosthetic joint infections (PJIs) and osteomyelitis are clinical challenges that are difficult to eradicate. Well-characterized large animal models necessary for testing and validating new treatment strategies for these conditions are lacking. The purpose of this study was to develop a rabbit model of chronic PJI in the distal femur. Methods. Fresh suspensions of Staphylococcus aureus (ATCC 25923) were prepared in phosphate-buffered saline (PBS) (1 × 10. 9. colony-forming units (CFUs)/ml). Periprosthetic osteomyelitis in female New Zealand white rabbits was induced by intraosseous injection of planktonic bacterial suspension into a predrilled bone tunnel prior to implant screw placement, examined at five and 28 days (n = 5/group) after surgery, and compared to a control aseptic screw group. Radiographs were obtained weekly, and blood was collected to measure ESR, CRP, and white blood cell (WBC) counts. Bone samples and implanted screws were harvested on day 28, and processed for histological analysis and viability assay of bacteria, respectively. Results. Intraosseous periprosthetic introduction of planktonic bacteria induced an acute rise in ESR and CRP that subsided by day 14, and resulted in radiologically evident periprosthetic osteolysis by day 28 accompanied by elevated WBC counts and histological evidence of bacteria in the bone tunnels after screw removal. The aseptic screw group induced no increase in ESR, and no lysis developed around the implants. Bacterial viability was confirmed by implant sonication fluid culture. Conclusion. Intraosseous periprosthetic introduction of planktonic bacteria reliably induces survivable chronic PJI in rabbits. Cite this article: Bone Joint Res 2021;10(3):156–165


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 411 - 414
1 Feb 2021
Wordie SJ Bugler KE Bessell PR Robb JE Gaston MS

Aims. The migration percentage (MP) is one criterion used for surgery in dislocated or displaced hips in children with cerebral palsy (CP). The MP at which a displaced hip can no longer return to normal is unclear. The aim of this paper was to identify the point of no return of the MP through a large population-based study. Methods. All children registered on the Cerebral Palsy Integrated Pathway Scotland surveillance programme undergo regular pelvic radiographs. Any child who had a MP measuring over 35% since the programme’s inception in 2013, in at least one hip and at one timepoint, was identified. The national radiography database was then interrogated to identify all pelvic radiographs for each of these children from birth through to the date of analysis. A minimum of a further two available radiographs following the initial measurement of MP ≥ 35% was required for inclusion. Results. A total of 239 children (346 hips) were identified as suitable for analysis at a mean of 6.5 years (2.0 to 14.8) follow-up. In all, 1,485 radiographs taken both prior to and after a hip had a MP ≥ 35% were examined and the MP measured to identify any progression of displacement. Interrogation of the data identified that hips with a MP up to 46% returned to a MP below 40% without intervention, and all hips with a MP equal to or greater than 46% displaced further and the MP did not return to the normal range. Statistical analysis showed the result to be 98% specific with this degree of certainty that hips reaching a MP ≥ 46% would not spontaneously regress. Conclusion. These findings are clinically relevant in showing that it may be reasonable to continue to monitor hips with a MP not exceeding 46%. This threshold will also guide referral for further management of a displacing hip. Cite this article: Bone Joint J 2021;103-B(2):411–414


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims. This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type. Results. A total of 584 cases were included. Median age was 79.1 years (interquartile range 72.0 to 86.0), 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The most common AO/OTA type was spiral (352, 60.3%). Metaphyseal split fractures occurred only with PTS stems with an incidence of 10.1%. Male sex was associated with a five-fold reduction in odds of a type C fracture (OR 0.22 (95% CI 0.12 to 0.41); p < 0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51 (95% CI 3.72 to 24.34); p < 0.001) and wedge fracture (OR 3.72 (95% CI 1.16 to 11.95); p = 0.027) compared to PTS stems. Both UCS grade and AO/OTA type differed significantly (p < 0.001 and p = 0.001, respectively) between the revision and fixation groups but a similar proportion of B1 fractures underwent revision compared to fixation (45.3% vs 50.6%). Conclusion. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems have higher odds of bending type fractures (transverse and wedge) compared to PTS stems. There is considerable variation in practice when treating B1 fractures around cemented stems. Cite this article: Bone Jt Open 2021;2(7):466–475


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 644 - 649
1 Apr 2021
Alsousou J Oragu E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S

Aims. The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA). Methods. A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported. Results. At two years, the mean subsidence of the head and tip for the TriFit stem was 0.38 mm (SD 0.32) and 0.52 mm (SD 0.36), respectively. The total migration of the head and tip was 0.55 mm (SD 0.32) and 0.71 mm (SD 0.38), respectively. There were no statistically significant differences between the three to 12 months' migration (p = 0.105) and 12 to 24 months' migration (p = 0.694). The OHS and EQ-5D showed significant improvements at two years. Conclusion. The results of this study suggest that the TriFit femoral stem achieves initial stability and is likely to be stable in the mid and long term. A long-term outcome study is required to assess late mechanisms of failure and the effects of bone mineral density (BMD) related changes. Cite this article: Bone Joint J 2021;103-B(4):644–649


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 299 - 304
1 Feb 2021
Goto E Umeda H Otsubo M Teranishi T

Aims. Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. Methods. A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation. Results. Radiographs immediately after surgery showed a mean vertical distance from the centre of the hip to the teardrop line of 21.5 mm (SD 3.3; 14.5 to 30.7) and a mean cover of the acetabular component by bone graft of 46% (SD 6%; 32% to 60%). All bone grafts united without collapse, and only three acetabular components loosened. The rate of survival of the acetabular component with mechanical loosening or revision as the endpoint was 86.4% at 25 years after surgery. Conclusion. The technique of using autologous bone graft from the femoral neck and placing a cemented acetabular component in the true acetabulum can provide good long-term outcomes in patients with Crowe type III dislocated hips. Cite this article: Bone Joint J 2021;103-B(2):299–304


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1100 - 1105
1 Aug 2018
Howard EL Shepherd KL Cribb G Cool P

Aims. The aim of this study was to validate the Mirels score in predicting pathological fractures in metastatic disease of the lower limb. Patients and Methods. A total of 62 patients with confirmed metastatic disease met the inclusion criteria. Of the 62 patients, 32 were female and 30 were male. The mean age of patients was 65 years (35 to 89). The primary malignancy originated from the breast in 27 (44%) patients, prostate in 15 (24%) patients, kidney in seven (11%), and lung in four (6%) of patients. One patient (2%) had metastatic carcinoma from the lacrimal gland, two patients (3%) had multiple myeloma, one patient (2%) had lymphoma of bone, and five patients (8%) had metastatic carcinoma of unknown primary. Plain radiographs at the time of initial presentation were scored using Mirels system by the four authors. The radiographic components of the score (anatomical site, size, and radiographic appearance) were scored two weeks apart. Inter- and intraobserver reliability were calculated with Fleiss’ kappa test. Bland-Altman plots were created to compare the variances of the individual components of the score and the total Mirels score. Results. Kappa values for the interobserver variability of the components of the Mirels score were k = 0.554 (95% CI 0.483 to 0.626) for site, k = 0.342 (95% CI 0.285 to 0.400) for size, k = 0.443 (95% CI 0.387 to 0.499) for radiographic appearance, and k = 0.294 (95% CI 0.258 to 0.331)for the total score. Kappa values for the intra-observer reliability were k = 0.608 (95% CI 0.506 to 0.710) for site, k = 0.579 (95% CI 0.487 to 0.670) for size, k = 0.614 (95% CI 0.522 to 0.703) for radiographic appearance, and k = 0.323 (95% CI 0.266 to 0.379) for total score. Conclusion. Our study showed fair to moderate agreement between authors when using the Mirels score, and moderate to substantial agreement when authors rescored radiographs. The Mirels score is subjective and lacks reproducibility in predicting the risk of pathological fracture. Cite this article: Bone Joint J 2018;100-B:1100–5


Bone & Joint Open
Vol. 2, Issue 9 | Pages 696 - 704
1 Sep 2021
Malhotra R Gautam D Gupta S Eachempati KK

Aims. Total hip arthroplasty (THA) in patients with post-polio residual paralysis (PPRP) is challenging. Despite relief in pain after THA, pre-existing muscle imbalance and altered gait may cause persistence of difficulty in walking. The associated soft tissue contractures not only imbalances the pelvis, but also poses the risk of dislocation, accelerated polyethylene liner wear, and early loosening. Methods. In all, ten hips in ten patients with PPRP with fixed pelvic obliquity who underwent THA as per an algorithmic approach in two centres from January 2014 to March 2018 were followed-up for a minimum of two years (2 to 6). All patients required one or more additional soft tissue procedures in a pre-determined sequence to correct the pelvic obliquity. All were invited for the latest clinical and radiological assessment. Results. The mean Harris Hip Score at the latest follow-up was 79.2 (68 to 90). There was significant improvement in the coronal pelvic obliquity from 16.6. o. (SD 7.9. o. ) to 1.8. o. (SD 2.4. o. ; p < 0.001). Radiographs of all ten hips showed stable prostheses with no signs of loosening or migration, regardless of whether paralytic or non-paralytic hip was replaced. No complications, including dislocation or infection related to the surgery, were observed in any patient. The subtrochanteric shortening osteotomy done in two patients had united by nine months. Conclusion. Simultaneous correction of soft tissue contractures is necessary for obtaining a stable hip with balanced pelvis while treating hip arthritis by THA in patients with PPRP and fixed pelvic obliquity. Cite this article: Bone Jt Open 2021;2(9):696–704


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Methods. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. Results. Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. Conclusion. This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339–1344


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 568 - 574
1 May 2023
Kobayashi H Ito N Nakai Y Katoh H Okajima K Zhang L Tsuda Y Tanaka S

Aims

The aim of this study was to report the patterns of symptoms and insufficiency fractures in patients with tumour-induced osteomalacia (TIO) to allow the early diagnosis of this rare condition.

Methods

The study included 33 patients with TIO who were treated between January 2000 and June 2022. The causative tumour was detected in all patients. We investigated the symptoms and evaluated the radiological patterns of insufficiency fractures of the rib, spine, and limbs.