Advertisement for orthosearch.org.uk
Results 1 - 100 of 665
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1669 - 1673
1 Dec 2014
Van der Merwe JM Haddad FS Duncan CP

The Unified Classification System (UCS) was introduced because of a growing need to have a standardised universal classification system of periprosthetic fractures. It combines and simplifies many existing classification systems, and can be applied to any fracture around any partial or total joint replacement occurring during or after operation. Our goal was to assess the inter- and intra-observer reliability of the UCS in association with knee replacement when classifying fractures affecting one or more of the femur, tibia or patella. We used an international panel of ten orthopaedic surgeons with subspecialty fellowship training and expertise in adult hip and knee reconstruction (‘experts’) and ten residents of orthopaedic surgery in the last two years of training (‘pre-experts’). They each received 15 radiographs for evaluation. After six weeks they evaluated the same radiographs again but in a different order. . The reliability was assessed using the Kappa and weighted Kappa values. The Kappa values for inter-observer reliability for the experts and the pre-experts were 0.741 (95% confidence interval (CI) 0.707 to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted Kappa values for intra-observer reliability for the experts and pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI 0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and ‘near perfect’ intra-observer reliability when used for periprosthetic fractures in association with knee replacement in the hands of experienced and inexperienced users. Cite this article: Bone Joint J 2014;96-B:1669–73


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims. United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures. Methods. A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up. Results. For the total cohort, stem osseointegration, fracture union, and stem subsidence were 98.6%, 98.6%, and 6.9%, respectively, at latest follow-up (mean follow-up 27.0 months (SD 22.4)). For patients with minimum one-year of follow-up, stem osseointegration, fracture union, and stem subsidence were 97.8%, 97.8%, and 6.5%, respectively. Conclusion. Monoblock fluted stems can be an acceptable modality for the management of UCS B2 periprosthetic fractures in rTHAs due to high rates of stem osseointegration and survival, and the low rates of stem subsidence, and revision. Further research on the use of this stem for UCS B3 periprosthetic fractures is warranted to determine if the same conclusion can be made for this fracture pattern. Cite this article: Bone Jt Open 2023;4(8):551–558


Bone & Joint Open
Vol. 5, Issue 6 | Pages 452 - 456
1 Jun 2024
Kennedy JW Rooney EJ Ryan PJ Siva S Kennedy MJ Wheelwright B Young D Meek RMD

Aims. Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures. Methods. We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups. Results. A total of 365 patients were identified: 140 in the early and 225 in the delayed intervention group. Mortality rate was 4.1% at 30 days and 19.2% at one year. There was some indication that those who had surgery within 36 hours had a higher mortality rate, but this did not reach statistical significance at 30 days (p = 0.078) or one year (p = 0.051). Univariate analysis demonstrated that age, preoperative haemoglobin, acute medical issue on admission, and the presence of postoperative complications influenced 30-day and one-year mortality. Using a multivariate model, age and preoperative haemoglobin were independently predictive factors for one-year mortality (odds ratio (OR) 1.071; p < 0.001 and OR 0.980; p = 0.020). There was no association between timing of surgery and postoperative complications. Postoperative complications were more likely with increasing age (OR 1.032; p = 0.001) and revision arthroplasty compared to internal fixation (OR 0.481; p = 0.001). Conclusion. While early intervention may be preferable to reduce prolonged immobilization, there is no evidence that delaying surgery beyond 36 hours increases mortality or complications in patients with a femoral periprosthetic fracture. Cite this article: Bone Jt Open 2024;5(6):452–456


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 416 - 423
1 Apr 2022
Mourkus H Phillips NJ Rangan A Peach CA

Aims. The aim of this study was to investigate the outcome of periprosthetic fractures of the humerus and to assess the uniformity of the classifications used for these fractures (including those around elbow and/or shoulder arthroplasties) by performing a systematic review of the literature. Methods. A systematic search was conducted using the National Institute for Health and Care Excellence Healthcare Databases Advance Search. For inclusion, studies had to report clinical outcomes following the management of periprosthetic fractures of the humerus. The protocol was registered on the PROSPERO database. Results. Overall, 40 studies were included, involving a total of 210 patients. The fractures were reported using very heterogeneous classification systems, as were the functional outcome scores. A total of 60 patients had nonoperative treatment with a 50% rate of nonunion. Fixation was undertaken in 99 patients; successful union was obtained in 93 (93%). Revision of either the humeral stem or the whole arthroplasty was reported in 79 patients with a high rate of union (n = 66; 84%), and a mean rate of complications of 29% (0% to 41%). Conclusion. This study highlighted a lack of uniformity in classifying these fractures and reporting the outcome of their treatment. The results may help to inform decision-making with patients, particularly about the rate of complications of nonoperative treatment. There is a need to improve the reporting of the pattern of these fractures using a uniform classification system, and the harmonization of the collection of data relating to the outcome of treatment. Based on this review, we propose a minimum dataset to be used in future studies. Cite this article: Bone Joint J 2022;104-B(4):416–423


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 987 - 996
1 Aug 2022

Aims. The aim of this study was to describe the demographic details of patients who sustain a femoral periprosthetic fracture (PPF), the epidemiology of PPFs, PPF characteristics, and the predictors of PPF types in the UK population. Methods. This is a multicentre retrospective cohort study including adult patients presenting to hospital with a new PPF between 1 January 2018 and 31 December 2018. Data collected included: patient characteristics, comorbidities, anticoagulant use, social circumstances, level of mobility, fracture characteristics, Unified Classification System (UCS) type, and details of the original implant. Descriptive analysis by fracture location was performed, and predictors of PPF type were assessed using mixed-effects logistic regression models. Results. In total, 720 femoral PPFs from 27 NHS sites were included. PPF patients were typically elderly (mean 79.9 years (SD 10.6)), female (n = 455; 63.2%), had at least one comorbidity (n = 670; 93.1%), and were reliant on walking aids or bed-/chair-bound prior to admission (n = 419; 61.7%). The study population included 539 (74.9%) hip PPFs, 151 (21.0%) knee PPFs, and 30 (4.2%) dividing type PPFs. For hip (n = 407; 75.5%) and knee (n = 88; 58.3%) arthroplasty UCS B type fractures were most common. Overall, 556 (86.2%) were treated in the presenting hospital and 89 (13.8%) required transfer for treatment. Female sex was the only significant predictor of fracture type (A/B1/C type versus B2/B3) for femoral hip PPFs (odds ratio 0.61 (95% confidence interval 0.41 to 0.91); p = 0.014). Sex, residence type, primary versus revision implant PPF, implant fixation, and time between arthroplasty and PPF were not found to predict fracture type for hip PPFs. Conclusion. This multicentre analysis describes patient and injury factors for patients presenting with femoral PPFs to centres across the UK. These patients are generally elderly and frail, comparable to those sustaining a hip fracture. These data can be useful in planning future services and clinical trials. Cite this article: Bone Joint J 2022;104-B(8):987–996


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 158 - 165
1 Feb 2024
Nasser AAHH Sidhu M Prakash R Mahmood A

Aims. Periprosthetic fractures (PPFs) around the knee are challenging injuries. This study aims to describe the characteristics of knee PPFs and the impact of patient demographics, fracture types, and management modalities on in-hospital mortality. Methods. Using a multicentre study design, independent of registry data, we included adult patients sustaining a PPF around a knee arthroplasty between 1 January 2010 and 31 December 2019. Univariate, then multivariable, logistic regression analyses were performed to study the impact of patient, fracture, and treatment on mortality. Results. Out of a total of 1,667 patients in the PPF study database, 420 patients were included. The in-hospital mortality rate was 6.4%. Multivariable analyses suggested that American Society of Anesthesiologists (ASA) grade, history of peripheral vascular disease (PVD), history of rheumatic disease, fracture around a loose implant, and cerebrovascular accident (CVA) during hospital stay were each independently associated with mortality. Each point increase in ASA grade independently correlated with a four-fold greater mortality risk (odds ratio (OR) 4.1 (95% confidence interval (CI) 1.19 to 14.06); p = 0.026). Patients with PVD have a nine-fold increase in mortality risk (OR 9.1 (95% CI 1.25 to 66.47); p = 0.030) and patients with rheumatic disease have a 6.8-fold increase in mortality risk (OR 6.8 (95% CI 1.32 to 34.68); p = 0.022). Patients with a fracture around a loose implant (Unified Classification System (UCS) B2) have a 20-fold increase in mortality, compared to UCS A1 (OR 20.9 (95% CI 1.61 to 271.38); p = 0.020). Mode of management was not a significant predictor of mortality. Patients managed with revision arthroplasty had a significantly longer length of stay (median 16 days; p = 0.029) and higher rates of return to theatre, compared to patients treated nonoperatively or with fixation. Conclusion. The mortality rate in PPFs around the knee is similar to that for native distal femur and neck of femur fragility fractures. Patients with certain modifiable risk factors should be optimized. A national PPF database and standardized management guidelines are currently required to understand these complex injuries and to improve patient outcomes. Cite this article: Bone Joint J 2024;106-B(2):158–165


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 997 - 1008
1 Aug 2022

Aims. The aim of this study was to describe the management and associated outcomes of patients sustaining a femoral hip periprosthetic fracture (PPF) in the UK population. Methods. This was a multicentre retrospective cohort study including adult patients who presented to 27 NHS hospitals with 539 new PPFs between 1 January 2018 and 31 December 2018. Data collected included: management strategy (operative and nonoperative), length of stay, discharge destination, and details of post-treatment outcomes (reoperation, readmission, and 30-day and 12-month mortality). Descriptive analysis by fracture type was performed, and predictors of PPF management and outcomes were assessed using mixed-effects logistic regression. Results. In all, 417 fractures (77%) were managed operatively and 122 (23%) conservatively. The median time to surgery was four days (interquartile range (IQR) 2 to 7). Of those undergoing surgery, 246 (59%) underwent revision and/or fixation and 169 (41%) fixation alone. The surgical strategy used differed by Unified Classification System for PPF type, with the highest rate of revision in B2/B3 fractures (both 77%, 176/228 and 24/31, respectively) and the highest rate of fixation alone in B1- (55/78; 71%) and C-type (49/65; 75%) fractures. Cemented stem fixation (odds ratio (OR) 2.66 (95% confidence interval (CI) 1.42 to 4.99); p = 0.002) and B2/B3 fracture type (OR 7.56 (95% CI 4.14 to 13.78); p < 0.001) were predictors of operative management. The median length of stay was 15 days (IQR 9 to 23), 12-month reoperation rate was 5.6% (n = 30), and 30-day readmission rate was 8.4% (n = 45). The 30-day and 12-month mortality rates were 5.2% (n = 28) and 21.0% (n = 113). Nonoperative treatment, older age, male sex, admission from residential or nursing care, and sustaining the PPF around a revision prosthesis were significant predictors of an increased 12-month mortality. Conclusion. Femoral hip PPFs have mortality, reoperation, and readmission rates comparable with hip fracture patients. However, they have a longer wait for surgery, and surgical treatment is more complex. There is a need to create a national framework for data collection for this heterogeneous group of patients in order to understand the outcomes of different approaches to treatment. Cite this article: Bone Joint J 2022;104-B(8):997–1008


Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims. Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade. Methods. Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 580 - 585
1 May 2020
Gibbs VN McCulloch RA Dhiman P McGill A Taylor AH Palmer AJR Kendrick BJL

Aims. The aim of this study was to identify modifiable risk factors associated with mortality in patients requiring revision total hip arthroplasty (THA) for periprosthetic hip fracture. Methods. The electronic records of consecutive patients undergoing revision THA for periprosthetic hip fracture between December 2011 and October 2018 were reviewed. The data which were collected included age, sex, body mass index (BMI), American Society of Anesthesiologists (ASA) classification, the preoperative serum level of haemoglobin, time to surgery, operating time, blood transfusion, length of hospital stay, and postoperative surgical and medical complications. Univariate and multivariate logistic regression analyses were used to determine independent modifiable factors associated with mortality at 90 days and one year postoperatively. Results. A total of 203 patients were identified. Their mean age was 78 years (44 to 100), and 108 (53%) were female. The median time to surgery was three days (interquartile range (IQR) 2 to 5). The mortality rate at one year was 13.8% (n = 28). The commonest surgical complication was dislocation (n = 22, 10.8%) and the commonest medical complication within 90 days of surgery was hospital-acquired pneumonia (n = 25, 12%). Multivariate analysis showed that the rate of mortality one year postoperatively was five-fold higher in patients who sustained a dislocation (odds ratio (OR) 5.03 (95% confidence interval (CI) 1.60 to 15.83); p = 0.006). The rate of mortality was also four-fold higher in patients who developed hospital-acquired pneumonia within 90 days postoperatively (OR 4.43 (95% CI 1.55 to 12.67); p = 0.005). There was no evidence that the time to surgery was a risk factor for death at one year. Conclusion. Dislocation and hospital-acquired pneumonia following revision THA for a periprosthetic fracture are potentially modifiable risk factors for mortality. This study suggests that surgeons should consider increasing constraint to reduce the risk of dislocation, and the early involvement of a multidisciplinary team to reduce the risk of hospital-acquired pneumonia. We found no evidence that the time to surgery affected mortality, which may allow time for medical optimization, surgical planning, and resource allocation. Cite this article: Bone Joint J 2020;102-B(5):580–585


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 950 - 956
1 Jul 2015
Tsitsilonis S Schaser KD Wichlas F Haas NP Manegold S

The incidence of periprosthetic fractures of the ankle is increasing. However, little is known about the outcome of treatment and their management remains controversial. The aim of this study was to assess the impact of periprosthetic fractures on the functional and radiological outcome of patients with a total ankle arthroplasty (TAA). A total of 505 TAAs (488 patients) who underwent TAA were retrospectively evaluated for periprosthetic ankle fracture: these were then classified according to a recent classification which is orientated towards treatment. The outcome was evaluated clinically using the American Orthopedic Foot and Ankle Society (AOFAS) score and a visual analogue scale for pain, and radiologically. . A total of 21 patients with a periprosthetic fracture of the ankle were identified. There were 13 women and eight men. The mean age of the patients was 63 years (48 to 74). Thus, the incidence of fracture was 4.17%. . There were 11 intra-operative and ten post-operative fractures, of which eight were stress fractures and two were traumatic. The prosthesis was stable in all patients. Five stress fractures were treated conservatively and the remaining three were treated operatively. . A total of 17 patients (81%) were examined clinically and radiologically at a mean follow-up of 53.5 months (12 to 112). The mean AOFAS score at follow-up was 79.5 (21 to 100). The mean AOFAS score in those with an intra-operative fracture was 87.6 (80 to 100) and for those with a stress fracture, which were mainly because of varus malpositioning, was 67.3 (21 to 93). Periprosthetic fractures of the ankle do not necessarily adversely affect the clinical outcome, provided that a treatment algorithm is implemented with the help of a new classification system. . Cite this article: Bone Joint J 2015;97-B:950–6


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 481 - 486
1 May 2023
Scott CEH Jain S Moran M Haddad FS

The Unified Classification System (UCS), or Vancouver system, is a validated and widely used classification system to guide the management of periprosthetic femoral fractures. It suggests that well-fixed stems (type B1) can be treated with fixation but that loose stems (types B2 and B3) should be revised. Determining whether a stem is loose can be difficult and some authors have questioned how to apply this classification system to polished taper slip stems which are, by definition, loose within their cement mantle. Recent evidence has challenged the common perception that revision surgery is preferable to fixation surgery for UCS-B periprosthetic fractures around cemented polished taper slip stems. Indications for fixation include an anatomically reducible fracture and cement mantle, a well-fixed femoral bone-cement interface, and a well-functioning acetabular component. However, not all type B fractures can or should be managed with fixation due to the risk of early failure. This annotation details specific fracture patterns that should not be managed with fixation alone. Cite this article: Bone Joint J 2023;105-B(5):481–486


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 48 - 55
1 Nov 2014
Yasen AT Haddad FS

We are currently facing an epidemic of periprosthetic fractures around the hip. They may occur either during surgery or post-operatively. Although the acetabulum may be involved, the femur is most commonly affected. We are being presented with new, difficult fracture patterns around cemented and cementless implants, and we face the challenge of an elderly population who may have grossly deficient bone and may struggle to rehabilitate after such injuries. The correct surgical management of these fractures is challenging. This article will review the current choices of implants and techniques available to deal with periprosthetic fractures of the femur. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):48–55


Bone & Joint 360
Vol. 13, Issue 5 | Pages 39 - 42
1 Oct 2024

The October 2024 Trauma Roundup. 360. looks at: Early versus delayed weightbearing following operatively treated ankle fracture (WAX): a non-inferiority, multicentre, randomized controlled trial; The effect of early weightbearing and later weightbearing rehabilitation interventions on outcomes after ankle fracture surgery; Is intramedullary nailing of femoral diaphyseal fractures in the lateral decubitus position as safe and effective as on a traction table?; Periprosthetic fractures of the hip: Back to the Future, Groundhog Day, and horses for courses; Two big bones, one big decision: when to fix bilateral femur fractures; Comparison of ankle fracture fixation using intramedullary fibular nailing versus plate fixation; Unclassified acetabular fractures: do they really exist?


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1489 - 1496
1 Nov 2016
Konan S Sandiford N Unno F Masri BS Garbuz DS Duncan CP

Fractures around total knee arthroplasties pose a significant surgical challenge. Most can be managed with osteosynthesis and salvage of the replacement. The techniques of fixation of these fractures and revision surgery have evolved and so has the assessment of outcome. This specialty update summarises the current evidence for the classification, methods of fixation, revision surgery and outcomes of the management of periprosthetic fractures associated with total knee arthroplasty. Cite this article: Bone Joint J 2016;98-B:1489–96


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 71 - 78
1 Jan 2021
Maggs JL Swanton E Whitehouse SL Howell JR Timperley AJ Hubble MJW Wilson MJ

Aims. Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification. Methods. We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment. Results. In total, 47 B2W fractures (54.0%) and one B3 fracture (1.1%) had cement that remained well-fixed at the cement-bone interface. These cases were treated with cement-in-cement (CinC) revision arthroplasty. Overall, 43 fractures with follow-up united, and two patients sustained further fractures secondary to nonunion and required further revision surgery. A total of 19 B2L fractures (21.8%) and 19 B3 fractures (21.8%) had cement that was loose at the cement-bone interface. These cases were managed by revision arthroplasty with either cemented or uncemented femoral components, or proximal femoral arthroplasty. One case could not be classified. Conclusion. We endorse a modification of the original Vancouver system to include a subclassification of B2 fractures around cemented femoral prostheses to include B2W (where cement is well-fixed to bone) and B2L (where the cement is loose). Fractures around taper-slip design stems are more likely to fracture in a B2W pattern compared to fractures around composite beam design stems which are more likely to fracture in a B2L pattern. B2W fractures can reliably be managed with CinC revision. Cite this article: Bone Joint J 2021;103-B(1):71–78


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 451 - 457
1 Apr 2017
Gromov K Bersang A Nielsen CS Kallemose T Husted H Troelsen A

Aims. The aim of this study was to identify patient- and surgery-related risk factors for sustaining an early periprosthetic fracture following primary total hip arthroplasty (THA) performed using a double-tapered cementless femoral component (Bi-Metric femoral stem; Biomet Inc., Warsaw, Indiana). Patients and Methods. A total of 1598 consecutive hips, in 1441 patients receiving primary THA between January 2010 and June 2015, were retrospectively identified. Level of pre-operative osteoarthritis, femoral Dorr type and cortical index were recorded. Varus/valgus placement of the stem and canal fill ratio were recorded post-operatively. Periprosthetic fractures were identified and classified according to the Vancouver classification. Regression analysis was performed to identify risk factors for early periprosthetic fracture. Results. The mean follow-up was 713 days (1 to 2058). A total of 48 periprosthetic fractures (3.0%) were identified during the follow-up and median time until fracture was 16 days, (interquartile range 10 to 31.5). Patients with femoral Dorr type C had a 5.2 times increased risk of post-operative periprosthetic fracture compared with type B, while female patients had a near significant two times increased risk over time for post-operative fracture. Conclusion. Dorr type C is an independent risk factor for early periprosthetic fracture, following THA using a double tapered cementless stem such as the Bi-Metric. Surgeons should take bone morphology into consideration when planning for primary THA and consider using cemented femoral components in female patients with poor bone quality. Cite this article: Bone Joint J 2017;99-B:451–7


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 26 - 30
1 Jan 2006
Lindahl H Malchau H Odén A Garellick G

Periprosthetic fracture of the femur is an uncommon complication after total hip replacement, but appears to be increasing. We undertook a nationwide observational study to determine the risk factors for failure after treatment of these fractures, examining patient- and implant-related factors, the classification of the fractures and the outcome. Between 1979 and 2000, 1049 periprosthetic fractures of the femur were reported to the Swedish National Hip Arthroplasty Register. Of these, 245 had a further operation after failure of their initial management. Data were collected from the Register and hospital records. The material was analysed by the use of Poisson regression models. It was found that the risk of failure of treatment was reduced for Vancouver type B2 injuries (p = 0.0053) if revision of the implant was undertaken (p = 0.0033) or revision and open reduction and internal fixation (p = 0.0039) were performed. Fractures classified as Vancouver type B1 had a significantly higher risk of failure (p = 0.0001). The strongest negative factor was the use of a single plate for fixation (p = 0.001). The most common reasons for failure in this group were loosening of the femoral prosthesis, nonunion and re-fracture. It is probable that many fractures classified as Vancouver type B1 (n = 304), were in reality type B2 fractures with a loose stem which were not recognised. Plate fixation was inadequate in these cases. The difficulty in separating type B1 from type B2 fractures suggests that the prosthesis should be considered as loose until proven otherwise


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1565 - 1571
1 Dec 2018
Kristensen TB Dybvik E Furnes O Engesæter LB Gjertsen J

Aims. The aim of this large registry-based study was to compare mid-term survival rates of cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck. Patients and Methods. From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included. Polished tapered stems (n = 12 065) (Exeter and CPT), straight stems (n = 5545) (Charnley, Charnley Modular, and Spectron EF), and anatomical stems (n = 2922) (Lubinus SP2) were included. The survival of the implant with any reoperation as the endpoint was calculated using the Kaplan–Meier method and hazard ratios (HRs), and the different indications for reoperation were calculated using Cox regression analysis. Results. The one-year survival was 96.0% (95% confidence interval (CI) 95.6 to 96.4) for the Exeter stem, 97.0% (95% CI 96.4 to 97.6) for the Lubinus SP2 stem, 97.6% (95% CI 97.0 to 98.2) for the Charnley stem, 98.1% (95% CI 97.3 to 98.9) for the Spectron EF stem, and 96.4% (95% CI 95.6 to 97.2) for the Charnley Modular stem, respectively. The hazard ratio for reoperation after one year was lower for Lubinus SP2 (HR 0.77, 95% CI 0.60 to 0.97), Charnley (HR 0.64, 95% CI 0.48 to 0.86), and Spectron EF stems (HR 0.44, 95% CI 0.29 to 0.67) compared with the Exeter stem. Reoperation for periprosthetic fracture occurred almost exclusively after the use of polished tapered stems. Conclusion. We were able to confirm that implant survival after cemented hemiarthroplasty for a hip fracture is high. Differences in rates of reoperation seem to favour anatomical and straight stems compared with polished tapered stems, which had a higher risk of periprosthetic fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1424 - 1430
1 Nov 2009
Corten K Vanrykel F Bellemans J Frederix PR Simon J Broos PLO

The use of plate-and-cable constructs to treat periprosthetic fractures around a well-fixed femoral component in total hip replacements has been reported to have high rates of failure. Our aim was to evaluate the results of a surgical treatment algorithm to use these lateral constructs reliably in Vancouver type-B1 and type-C fractures. The joint was dislocated and the stability of the femoral component was meticulously evaluated in 45 type-B1 fractures. This led to the identification of nine (20%) unstable components. The fracture was considered to be suitable for single plate-and-cable fixation by a direct reduction technique if the integrity of the medial cortex could be restored. Union was achieved in 29 of 30 fractures (97%) at a mean of 6.4 months (3 to 30) in 29 type-B1 and five type-C fractures. Three patients developed an infection and one construct failed. Using this algorithm plate-and-cable constructs can be used safely, but indirect reduction with minimal soft-tissue damage could lead to shorter times to union and lower rates of complications


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1347 - 1354
1 Oct 2016
Palan J Smith MC Gregg P Mellon S Kulkarni A Tucker K Blom AW Murray DW Pandit H

Aims. Periprosthetic fracture (PF) after primary total hip arthroplasty (THA) is an uncommon but potentially devastating complication. This study aims to investigate the influence of cemented stem designs on the risk of needing a revision for a PF. Patients and Methods. We analysed data on 257 202 primary THAs with cemented stems and 390 linked first revisions for PF recorded in the National Joint Registry (NJR) of England, Wales and Northern Ireland to determine if a cemented femoral stem brand was associated with the risk of having revision for a PF after primary THA. All cemented femoral stem brands with more than 10 000 primary operations recorded in the NJR were identified. The four most commonly used cemented femoral stems were the Exeter V40 (n = 146 409), CPT (n = 24 300), C-Stem (n = 15 113) and Charnley (n = 20 182). We compared the revision risk ratios due to PF amongst the stems using a Poisson regression model adjusting for patient factors. Compared with the Exeter V40, the age, gender and ASA grade adjusted revision rate ratio was 3.89 for the cemented CPT stem (95% confidence interval (CI) 3.07 to 4.93), 0.89 for the C-Stem (95% CI 0.57 to 1.41) and 0.41 for the Charnley stem (95% CI 0.24 to 0.70). Conclusions. The limitations of the study include incomplete data capture, analysis of only PF requiring revision and that observation does not imply causality. Nevertheless, this study demonstrates that the choice of a cemented stem may influence the risk of revision for PF. Cite this article: Bone Joint J 2016;98-B:1347–54


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 547 - 549
1 May 2020
Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 144 - 150
1 Feb 2024
Lynch Wong M Robinson M Bryce L Cassidy R Lamb JN Diamond O Beverland D

Aims

The aim of this study was to determine both the incidence of, and the reoperation rate for, postoperative periprosthetic femoral fracture (POPFF) after total hip arthroplasty (THA) with either a collared cementless (CC) femoral component or a cemented polished taper-slip (PTS) femoral component.

Methods

We performed a retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All POPFFs were identified using regional radiograph archiving and electronic care systems.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 115 - 120
1 Mar 2024
Ricotti RG Flevas DA Sokrab R Vigdorchik JM Mayman DJ Jerabek SA Sculco TP Sculco PK

Aims

Periprosthetic femoral fracture (PPF) is a major complication following total hip arthroplasty (THA). Uncemented femoral components are widely preferred in primary THA, but are associated with higher PPF risk than cemented components. Collared components have reduced PPF rates following uncemented primary THA compared to collarless components, while maintaining similar prosthetic designs. The purpose of this study was to analyze PPF rate between collarless and collared component designs in a consecutive cohort of posterior approach THAs performed by two high-volume surgeons.

Methods

This retrospective series included 1,888 uncemented primary THAs using the posterior approach performed by two surgeons (PKS, JMV) from January 2016 to December 2022. Both surgeons switched from collarless to collared components in mid-2020, which was the only change in surgical practice. Data related to component design, PPF rate, and requirement for revision surgery were collected. A total of 1,123 patients (59.5%) received a collarless femoral component and 765 (40.5%) received a collared component. PPFs were identified using medical records and radiological imaging. Fracture rates between collared and collarless components were analyzed. Power analysis confirmed 80% power of the sample to detect a significant difference in PPF rates, and a Fisher’s exact test was performed to determine an association between collared and collarless component use on PPF rates.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 11 - 15
1 Jan 2024
Jain S Lamb JN Pandit H

Polished taper-slip (PTS) cemented stems have an excellent clinical track record and are the most common stem type used in primary total hip arthroplasty (THA) in the UK. Due to low rates of aseptic loosening, they have largely replaced more traditional composite beam (CB) cemented stems. However, there is now emerging evidence from multiple joint registries that PTS stems are associated with higher rates of postoperative periprosthetic femoral fracture (PFF) compared to their CB stem counterparts. The risk of both intraoperative and postoperative PFF remains greater with uncemented stems compared to either of these cemented stem subtypes. PFF continues to be a devastating complication following primary THA and is associated with high complication and mortality rates. Recent efforts have focused on identifying implant-related risk factors for PFF in order to guide preventative strategies, and therefore the purpose of this article is to present the current evidence on the effect of cemented femoral stem design on the risk of PFF.

Cite this article: Bone Joint J 2024;106-B(1):11–15.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 309 - 320
1 Feb 2021
Powell-Bowns MFR Oag E Ng N Pandit H Moran M Patton JT Clement ND Scott CEH

Aims

The aim of this study was to determine whether fixation, as opposed to revision arthroplasty, can be safely used to treat reducible Vancouver B type fractures in association with a cemented collarless polished tapered femoral stem (the Exeter).

Methods

This retrospective cohort study assessed 152 operatively managed consecutive unilateral Vancouver B fractures involving Exeter stems; 130 were managed with open reduction and internal fixation (ORIF) and 22 with revision arthroplasty. Mean follow-up was 6.5 years (SD 2.6; 3.2 to 12.1). The primary outcome measure was revision of at least one component. Kaplan–Meier survival analysis was performed. Regression analysis was used to identify risk factors for revision following ORIF. Secondary outcomes included any reoperation, complications, blood transfusion, length of hospital stay, and mortality.


Aims

Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients.

Methods

A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 713 - 716
1 Jun 2014
Duncan CP Haddad FS

Periprosthetic fractures are an increasingly common complication following joint replacement. The principles which underpin their evaluation and treatment are common across the musculoskeletal system. The Unified Classification System proposes a rational approach to treatment, regardless of the bone that is broken or the joint involved. Cite this article: Bone Joint J 2014;96-B:713–16


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims. Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees. Methods. A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed. Results. There were 22 periprosthetic fractures; they occurred exclusively in the femur: two in the femoral neck, 14 intertrochanteric and six subtrochanteric, representing 4.2% of 518 osseointegration operations and 6.3% of 347 femoral implants. The vast majority (19/22, 86.4%) occurred within 2 cm of the proximal tip of the implant and after a fall. No fractures occurred spontaneously. Fixation most commonly involved dynamic hip screws (10) and reconstruction plates (9). No osseointegration implants required removal, the K-level was not reduced after fixation of the fracture in any patient, and all retained a K-level of ≥ 2. All fractures united, 21 out of 22 patients (95.5%) wear their osseointegration-mounted prosthetic limb longer daily than when using a socket, with 18 out of 22 (81.8%) reporting using it for ≥ 16 hours daily. Regression analysis identified a 3.89-fold increased risk of fracture for females (p = 0.007) and a 1.02-fold increased risk of fracture per kg above a mean of 80.4 kg (p = 0.046). No increased risk was identified for bilateral implants (p = 0.083), time from amputation to osseointegration (p = 0.974), age at osseointegration (p = 0.331), or bone density (g/cm2, p = 0.560; T-score, p = 0.247; Z-score, p = 0.312). Conclusion. The risks and sequelae of periprosthetic fracture after press-fit osseointegration for amputation should not deter patients or clinicians from considering this procedure. Females and heavier patients are likely to have an increased risk of fracture. Age, years since amputation, and bone density do not appear influential. Cite this article: Bone Joint J 2020;102-B(2):162–169


Aims

The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an intracapsular hip fracture.

Methods

This retrospective study included hip fracture patients aged 50 years and older treated with Exeter (PTS) bipolar hemiarthroplasty between 2019 and 2022. Patient demographics, place of domicile, fracture type, delirium status, American Society of Anesthesiologists (ASA) grade, length of stay, and mortality were collected. Reoperation and mortality were recorded up to a median follow-up of 29.5 months (interquartile range 12 to 51.4). Cox regression was performed to evaluate independent risk factors associated with reoperation and mortality.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 711 - 712
1 Jun 2014
Duncan CP


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 527 - 534
1 Apr 2010
Streubel PN Gardner MJ Morshed S Collinge CA Gallagher B Ricci WM

It is unclear whether there is a limit to the amount of distal bone required to support fixation of supracondylar periprosthetic femoral fractures. This retrospective multicentre study evaluated lateral locked plating of periprosthetic supracondylar femoral fractures and compared the results according to extension of the fracture distal with the proximal border of the femoral prosthetic component. Between 1999 and 2008, 89 patients underwent lateral locked plating of a supracondylar periprosthetic femoral fracture, of whom 61 patients with a mean age of 72 years (42 to 96) comprising 53 women, were available after a minimum follow-up of six months or until fracture healing. Patients were grouped into those with fractures located proximally (28) and those with fractures that extended distal to the proximal border of the femoral component (33). Delayed healing and nonunion occurred respectively in five (18%) and three (11%) of more proximal fractures, and in two (6%) and five (15%) of the fractures with distal extension (p = 0.23 for delayed healing; p = 0.72 for nonunion, Fisher’s exact test). Four construct failures (14%) occurred in more proximal fractures, and three (9%) in fractures with distal extension (p = 0.51). Of the two deep infections that occurred in each group, one resolved after surgical debridement and antibiotics, and one progressed to a nonunion. Extreme distal periprosthetic supracondylar fractures of the femur are not a contra-indication to lateral locked plating. These fractures can be managed with internal fixation, with predictable results, similar to those seen in more proximal fractures


Bone & Joint 360
Vol. 13, Issue 1 | Pages 13 - 16
1 Feb 2024

The February 2024 Hip & Pelvis Roundup. 360. looks at: Trial of vancomycin and cefazolin as surgical prophylaxis in arthroplasty; Is preoperative posterior femoral neck tilt a risk factor for fixation failure? Cemented versus uncemented hemiarthroplasty for displaced intracapsular fractures of the hip; Periprosthetic fractures in larger hydroxyapatite-coated stems: are collared stems a better alternative for total hip arthroplasty?; Postoperative periprosthetic fracture following hip arthroplasty with a polished taper slip versus composite beam stem; Is oral tranexamic acid as good as intravenous?; Stem design and the risk of early periprosthetic femur fractures following THA in elderly patients; Does powered femoral broaching compromise patient safety in total hip arthroplasty?


Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims. This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. Methods. We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018. Results. Of the surviving 30 patients (34 THAs), there were four periprosthetic fractures: one underwent femoral revision after 21 years, two had surgical fixation as the stem was deemed stable, and one was treated nonoperatively due to the patient’s comorbidities. The periprosthetic fracture patients showed radiological evidence of change in bone stock around the femoral stem, which may have contributed to the fractures; this was reflected in change of the canal flare index at the proximal femur. Two patients (two hips) were lost to follow-up. Using aseptic loosening as the endpoint, 16 patients (18 hips; 48%) needed acetabular revision. None of the femoral components were revised for aseptic loosening, demonstrating 100% survival. The estimate of the cumulative proportion surviving for revisions due to any cause was 0.97 (standard error 0.03). Conclusion. In young patients with high demands, the Furlong HAC-coated femoral component gives excellent long-term results. Cite this article: Bone Jt Open 2024;5(4):286–293


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 649 - 656
1 Jun 2023
Dagneaux L Amundson AW Larson DR Pagnano MW Berry DJ Abdel MP

Aims. Nonagenarians (aged 90 to 99 years) have experienced the fastest percent decile population growth in the USA recently, with a consequent increase in the prevalence of nonagenarians living with joint arthroplasties. As such, the number of revision total hip arthroplasties (THAs) and total knee arthroplasties (TKAs) in nonagenarians is expected to increase. We aimed to determine the mortality rate, implant survivorship, and complications of nonagenarians undergoing aseptic revision THAs and revision TKAs. Methods. Our institutional total joint registry was used to identify 96 nonagenarians who underwent 97 aseptic revisions (78 hips and 19 knees) between 1997 and 2018. The most common indications were aseptic loosening and periprosthetic fracture for both revision THAs and revision TKAs. Mean age at revision was 92 years (90 to 98), mean BMI was 27 kg/m. 2. (16 to 47), and 67% (n = 65) were female. Mean time between primary and revision was 18 years (SD 9). Kaplan-Meier survival was used for patient mortality, and compared to age- and sex-matched control populations. Reoperation risk was assessed using cumulative incidence with death as a competing risk. Mean follow-up was five years. Results. Mortality rates were 9%, 18%, 26%, and 62% at 90 days, one year, two years, and five years, respectively, but similar to control populations. There were 43 surgical complications and five reoperations, resulting in a cumulative incidence of reoperation of 4% at five years. Medical complications were common, with a cumulative incidence of 65% at 90 days. Revisions for periprosthetic fractures were associated with higher mortality and higher 90-day risk of medical complications compared to revisions for aseptic loosening. Conclusion. Contemporary revision THAs and TKAs appeared to be relatively safe in selected nonagenarians managed with multidisciplinary teams. Cause of revision affected morbidity and mortality risks. While early medical and surgical complications were frequent, they seldom resulted in reoperation. Cite this article: Bone Joint J 2023;105-B(6):649–656


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims. Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs. Methods. A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m. 2. (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19). Results. The ten-year survivorship free from revision was 91% (95% confidence interval (CI) 81 to 100) in affected and 84% (95% CI 68 to 100) in unaffected limbs. There were six revisions in affected limbs: three for periprosthetic femoral fractures and one each for periprosthetic joint infection (PJI), patellar clunk syndrome, and instability. Unaffected limbs were revised in four cases: two for instability and one each for PJI and tibial component loosening. The ten-year survivorship free from any reoperation was 86% (95% CI 75 to 97) and 80% (95% CI 64 to 99) in affected and unaffected limbs, respectively. There were three additional reoperations among affected and two in unaffected limbs. There were 12 nonoperative complications, including four periprosthetic fractures. Arthrofibrosis occurred in five affected (8%) and two unaffected limbs (4%). Postoperative range of motion decreased with 31% achieving less than 90° knee flexion by five years. Conclusion. TKAs in post-polio patients are complex cases associated with instability, and one in four require constraint on the affected side. Periprosthetic fracture was the main mode of failure. Arthrofibrosis rates were high and twice as frequent in affected limbs. Cite this article: Bone Joint J 2023;105-B(6):635–640


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 124 - 134
1 Feb 2023
Jain S Farook MZ Aslam-Pervez N Amer M Martin DH Unnithan A Middleton R Dunlop DG Scott CEH West R Pandit H

Aims. The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA). Methods. Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint. Results. A total of 317 periprosthetic fractures (in 317 patients) with a median follow-up of 3.6 years (interquartile range (IQR) 2.0 to 5.4) were included. The fractures were type B1 in 133 (42.0%), B2 in 170 (53.6%), and B3 in 14 patients (4.4%). ORIF was performed in 167 (52.7%) and revision in 150 patients (47.3%). The two-year reoperation rate (15.3% vs 7.2%; p = 0.021), time to surgery (4.0 days (IQR 2.0 to 7.0) vs 2.0 days (IQR 1.0 to 4.0); p < 0.001), transfusion requirements (55 patients (36.7%) vs 42 patients (25.1%); p = 0.026), critical care requirements (36 patients (24.0%) vs seven patients (4.2%); p < 0.001) and two-year local complication rates (26.7% vs 9.0%; p < 0.001) were significantly higher in the revision group. The two-year rate of survival was significantly higher for ORIF (91.9% (standard error (SE) 0.023%) vs 83.9% (SE 0.031%); p = 0.032) compared with revision. For B1 fractures, the two-year reoperation rate was significantly higher for revision compared with ORIF (29.4% vs 6.0%; p = 0.002) but this was similar for B2 and B3 fractures (9.8% vs 13.5%; p = 0.341). The most common indication for reoperation after revision was dislocation (12 patients; 8.0%). Conclusion. Revision surgery has higher reoperation rates, longer surgical waiting times, higher transfusion requirements, and higher critical care requirements than ORIF in the management of periprosthetic fractures around polished taper-slip femoral components after THA. ORIF is a safe option providing anatomical reconstruction is achievable. Cite this article: Bone Joint J 2023;105-B(2):124–134


Bone & Joint Open
Vol. 4, Issue 6 | Pages 457 - 462
26 Jun 2023
Bredgaard Jensen C Gromov K Petersen PB Jørgensen CC Kehlet H Troelsen A

Aims. Medial unicompartmental knee arthroplasty (mUKA) is an advised treatment for anteromedial knee osteoarthritis. While long-term survival after mUKA is well described, reported incidences of short-term surgical complications vary and the effect of surgical usage on complications is less established. We aimed to describe the overall occurrence and treatment of surgical complications within 90 days of mUKA, as well as occurrence in high-usage centres compared to low-usage centres. Methods. mUKAs performed in eight fast-track centres from February 2010 to June 2018 were included from the Lundbeck Foundation Centre for Fast-track Hip and Knee Replacement Database. All readmissions within 90 days of surgery underwent chart review and readmissions related to the surgical wound or the prosthesis were recorded. Centres were categorized as high-usage centres when using mUKA in ≥ 20% of annual knee arthroplasties. The occurrence of complications between high- and low-usage centres were compared using Fisher’s exact test. Results. We included 3,757 mUKAs: 2,377 mUKAs from high-usage centres and 1,380 mUKAs from low-usage centres. Surgical complications within 90 days occurred in 69 cases (1.8%), 45 (1.9%) in high-usage centres and 24 (1.7%) in low-usage centres (odds ratio (OR) 1.1 (95% confidence interval (CI) 0.65 to 1.8)). The most frequent complications were periprosthetic joint infections (PJIs) (n = 18; 0.48%), wound-related issues (n = 14; 0.37%), and periprosthetic fractures (n = 13; 0.35%). Bearing dislocations (n = 7; 0.19%) occurred primarily in procedures from high-usage centres. In high-usage centres, seven periprosthetic fractures (0.29%) occurred compared to six (0.43%) in low-usage centres (OR 0.68 (95% CI 0.20 to 2.0)). In high-usage centres, nine PJIs (0.38%) occurred compared to nine (0.65%) in low-usage centres (OR 0.58 (95% CI 0.22 to 1.6)). Conclusion. Surgical complications are rare after fast-track mUKA surgery and with no difference in overall occurrence of surgical complications between high- and low-usage centres, although the risk of some specific surgical complications may favour high-usage centres. Cite this article: Bone Jt Open 2023;4(6):457–462


Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results. In total, 1,312 Thompson’s hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4), acetabular erosion (n = 3), and metastatic bone disease (n = 1). Their status at ten years is summarized as follows: 1,180 (89.9%) dead without revision, 34 (2.6%) dead having had revision, 84 (6.6%) alive with the stem unrevised, and 14 (1.1%) alive having had revision. Cumulative implant survivorship was 90.3% at ten years; patient survivorship was 7.4%. Conclusion. The Thompson’s stem demonstrates very low rates of complications requiring reoperation and revision, up to ten years after the index procedure. Fewer than one in ten patients live for ten years after fracture. This study supports the use of a cemented Thompson’s implant as a cost-effective option for frail hip fracture patients. Cite this article: Bone Jt Open 2022;3(9):710–715


Bone & Joint Research
Vol. 13, Issue 6 | Pages 272 - 278
5 Jun 2024
Niki Y Huber G Behzadi K Morlock MM

Aims. Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model. Methods. Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods. Results. Impaction force was reduced by 89% and 53% for vibratory insertion in 15 and 30 PCF foams, respectively. Both methods positioned the component with polar gaps under 2 mm in 15 PCF foam. However, in 30 PCF foam, the vibratory insertion resulted in a clinically undesirable polar gap of over 2 mm. A higher lever-out moment was achieved with the consecutive single blow insertion by 42% in 15 PCF and 2.7 times higher in 30 PCF foam. Conclusion. Vibratory implant insertion may lower periprosthetic fracture risk by reducing impaction forces, particularly in low-quality bone. Achieving implant seating using vibratory insertion requires adjustment of the nominal press-fit, especially in denser bone. Further preclinical testing on real bone tissue is necessary to assess whether its viscoelasticity in combination with an adjusted press-fit can compensate for the reduced primary stability after vibratory insertion observed in this study. Cite this article: Bone Joint Res 2024;13(6):272–278


Bone & Joint Open
Vol. 3, Issue 3 | Pages 229 - 235
11 Mar 2022
Syam K Unnikrishnan PN Lokikere NK Wilson-Theaker W Gambhir A Shah N Porter M

Aims. With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases. Methods. A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS). Results. At mean follow-up of 5.9 years, there were no periprosthetic fractures. Clearance of infection was achieved in 63.6% of cases. One hip was re-revised to pseudo arthroplasty for deep infection. Instability was noted in eight of the hips (32%), of which seven needed further surgery. Out of these eight hips with instability, five had preoperative infection. Deep infection was noted in five of the hips (20%), of which four were primarily revised for infection. One patient had aseptic loosening of the femoral component and awaits revision surgery. The Kaplan-Meier survivorship free of revision of any component for any reason was 72% (95% confidence interval (CI) 51.3% to 92.7%), and for revisions of only femoral component for any reason was 96% (95% CI 86.3% to 105.7%) at five years. Conclusion. Dislocation and infection remain the major cause for failure, particularly in patients with pre-existing infection. The use of dual mobility cups, silver-coated implants, and less aggressive postoperative rehabilitation regimens would possibly aid in the reduction of complications. PFA performed in patients with periprosthetic fracture seem to fair better. This study supports the judicious use of PFA in non-oncological revision hip arthroplasties, and that they be performed by experienced revision arthroplasty surgeons. Cite this article: Bone Jt Open 2022;3(3):229–235


Bone & Joint 360
Vol. 13, Issue 3 | Pages 20 - 24
3 Jun 2024

The June 2024 Knee Roundup. 360. looks at: The estimated lifetime risk of revision after primary knee arthroplasty influenced by age, sex, and indication; Should high-risk patients seek out care from high-volume surgeons?; Stability and fracture rates in medial unicondylar knee arthroplasties; Rethinking antibiotic prophylaxis for dental procedures post-arthroplasty; Evaluating DAIR: a viable alternative for acute periprosthetic joint infection; The characteristics and predictors of mortality in periprosthetic fractures around the knee; Patient health-related quality of life deteriorates significantly while waiting six to 12 months for total hip or knee arthroplasty; The importance of looking for diversity in knee implants


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 59 - 67
1 Jan 2022
Kingsbury SR Smith LK Shuweihdi F West R Czoski Murray C Conaghan PG Stone MH

Aims. The aim of this study was to conduct a cross-sectional, observational cohort study of patients presenting for revision of a total hip, or total or unicompartmental knee arthroplasty, to understand current routes to revision surgery and explore differences in symptoms, healthcare use, reason for revision, and the revision surgery (surgical time, components, length of stay) between patients having regular follow-up and those without. Methods. Data were collected from participants and medical records for the 12 months prior to revision. Patients with previous revision, metal-on-metal articulations, or hip hemiarthroplasty were excluded. Participants were retrospectively classified as ‘Planned’ or ‘Unplanned’ revision. Multilevel regression and propensity score matching were used to compare the two groups. Results. Data were analyzed from 568 patients, recruited in 38 UK secondary care sites between October 2017 and October 2018 (43.5% male; mean (SD) age 71.86 years (9.93); 305 hips, 263 knees). No significant inclusion differences were identified between the two groups. For hip revision, time to revision > ten years (odds ratio (OR) 3.804, 95% confidence interval (CI) (1.353 to 10.694), p = 0.011), periprosthetic fracture (OR 20.309, 95% CI (4.574 to 90.179), p < 0.001), and dislocation (OR 12.953, 95% CI (4.014 to 41.794), p < 0.001), were associated with unplanned revision. For knee, there were no associations with route to revision. Revision after ten years was more likely for those who were younger at primary surgery, regardless of route to revision. No significant differences in cost outcomes, length of surgery time, and access to a health professional in the year prior to revision were found between the two groups. When periprosthetic fractures, dislocations, and infections were excluded, healthcare use was significantly higher in the unplanned revision group. Conclusion. Differences between characteristics for patients presenting for planned and unplanned revision are minimal. Although there was greater healthcare use in those having unplanned revision, it appears unlikely that routine orthopaedic review would have detected many of these issues. It may be safe to disinvest in standard follow-up provided there is rapid access to orthopaedic review. Cite this article: Bone Joint J 2022;104-B(1):59–67


Bone & Joint 360
Vol. 11, Issue 6 | Pages 15 - 18
1 Dec 2022

The December 2022 Hip & Pelvis Roundup. 360. looks at: Fix and replace: simultaneous fracture fixation and hip arthroplasty for acetabular fractures in older patients; Is the revision rate for femoral neck fracture lower for total hip arthroplasty than for hemiarthroplasty?; Femoral periprosthetic fractures: data from the COMPOSE cohort study; Dual-mobility cups and fracture of the femur; What’s the deal with outcomes for hip and knee arthroplasty outcomes internationally?; Osteochondral lesions of the femoral head: is costal cartilage the answer?


Bone & Joint 360
Vol. 12, Issue 2 | Pages 13 - 16
1 Apr 2023

The April 2023 Hip & Pelvis Roundup. 360. looks at: Do technical errors determine outcomes of operatively managed femoral neck fractures in younger adults?; Single-stage or two-stage revision for hip prosthetic joint infection (INFORM); Fixation better than revision in type B periprosthetic fractures of taper slip stems; Can you maximize femoral head size at the expense of liner thickness?; Plasma D-dimer for periprosthetic joint infection?; How important is in vivo oxidation?; Total hip arthroplasty for HIV patients with osteonecrosis


Bone & Joint Research
Vol. 13, Issue 10 | Pages 611 - 621
24 Oct 2024
Wan Q Han Q Liu Y Chen H Zhang A Zhao X Wang J

Aims. This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture. Methods. Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk. Results. During gait, varied sagittal positioning did not lead to excessive Von Mises stress or micromotion. However, under squat conditions, posterior positioning (-4 and -5 mm) resulted in stress exceeding 150 MPa at the femoral notch, indicating potential fracture risk. Conversely, +1 mm and 0 mm sagittal positions demonstrated minimal interface micromotion. Conclusion. Slightly anterior sagittal positioning (+1 mm) or neutral positioning (0 mm) effectively reduced stress concentration at the femoral notch and minimized interface micromotion. Thus, these positions are deemed suitable to decrease the risk of aseptic loosening and periprosthetic femoral fracture


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 779 - 786
1 Jul 2019
Lamb JN Baetz J Messer-Hannemann P Adekanmbi I van Duren BH Redmond A West RM Morlock MM Pandit HG

Aims. The aim of this study was to estimate the 90-day risk of revision for periprosthetic femoral fracture associated with design features of cementless femoral stems, and to investigate the effect of a collar on this risk using a biomechanical in vitro model. Materials and Methods. A total of 337 647 primary total hip arthroplasties (THAs) from the United Kingdom National Joint Registry (NJR) were included in a multivariable survival and regression analysis to identify the adjusted hazard of revision for periprosthetic fracture following primary THA using a cementless stem. The effect of a collar in cementless THA on this risk was evaluated in an in vitro model using paired fresh frozen cadaveric femora. Results. The prevalence of early revision for periprosthetic fracture was 0.34% (1180/337 647) and 44.0% (520/1180) occurred within 90 days of surgery. Implant risk factors included: collarless stem, non-grit-blasted finish, and triple-tapered design. In the in vitro model, a medial calcar collar consistently improved the stability and resistance to fracture. Conclusion. Analysis of features of stem design in registry data is a useful method of identifying implant characteristics that affect the risk of early periprosthetic fracture around a cementless femoral stem. A collar on the calcar reduced the risk of an early periprosthetic fracture and this was confirmed by biomechanical testing. This approach may be useful in the analysis of other uncommon modes of failure after THA. Cite this article: Bone Joint J 2019;101-B:779–786


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 254 - 260
1 Mar 2023
Bukowski BR Sandhu KP Bernatz JT Pickhardt PJ Binkley N Anderson PA Illgen R

Aims. Osteoporosis can determine surgical strategy for total hip arthroplasty (THA), and perioperative fracture risk. The aims of this study were to use hip CT to measure femoral bone mineral density (BMD) using CT X-ray absorptiometry (CTXA), determine if systematic evaluation of preoperative femoral BMD with CTXA would improve identification of osteopenia and osteoporosis compared with available preoperative dual-energy X-ray absorptiometry (DXA) analysis, and determine if improved recognition of low BMD would affect the use of cemented stem fixation. Methods. Retrospective chart review of a single-surgeon database identified 78 patients with CTXA performed prior to robotic-assisted THA (raTHA) (Group 1). Group 1 was age- and sex-matched to 78 raTHAs that had a preoperative hip CT but did not have CTXA analysis (Group 2). Clinical demographics, femoral fixation method, CTXA, and DXA data were recorded. Demographic data were similar for both groups. Results. Preoperative femoral BMD was available for 100% of Group 1 patients (CTXA) and 43.6% of Group 2 patients (DXA). CTXA analysis for all Group 1 patients preoperatively identified 13 osteopenic and eight osteoporotic patients for whom there were no available preoperative DXA data. Cemented stem fixation was used with higher frequency in Group 1 versus Group 2 (28.2% vs 14.3%, respectively; p = 0.030), and in all cases where osteoporosis was diagnosed, irrespective of technique (DXA or CTXA). Conclusion. Preoperative hip CT scans which are routinely obtained prior to raTHA can determine bone health, and thus guide femoral fixation strategy. Systematic preoperative evaluation with CTXA resulted in increased recognition of osteopenia and osteoporosis, and contributed to increased use of cemented femoral fixation compared with routine clinical care; in this small study, however, it did not impact short-term periprosthetic fracture risk. Cite this article: Bone Joint J 2023;105-B(3):254–260


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. Methods. We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification. Results. A total of seven stems (4.2%) were revised during the study period: one for aseptic loosening, three for periprosthetic fracture, two for infection, and one for recurrent dislocation. At 20 years, survival with revision of the stem for any indication and for aseptic loosening as the endpoint was 96.0% (95% confidence interval (CI) 92.6 to 99.5) and 98.4% (95% CI 96.2 to 100), respectively. At 25 years, the corresponding rates of survival were 94.5% (95% CI 89.9 to 99.3) and 98.1% (95% CI 95.7 to 99.6), respectively. There was radiological evidence of stable bony fixation in 86 stems (76.1%) and evidence of loosening in four (3.5%) at 20 years. All patients with radiological evidence of loosening were asymptomatic. Conclusion. The Omnifit HA femoral stem offered promising long-term survival into the third decade. Cite this article: Bone Joint J 2024;106-B(3 Supple A):110–114


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 888 - 894
1 Aug 2023
Murray J Jeyapalan R Davies M Sheehan C Petrie M Harrison T

Aims. Total femoral arthroplasty (TFA) is a rare procedure used in cases of significant femoral bone loss, commonly from cancer, infection, and trauma. Low patient numbers have resulted in limited published work on long-term outcomes, and even less regarding TFA undertaken for non-oncological indications. The aim of this study was to evaluate the long-term clinical outcomes of all TFAs in our unit. Methods. Data were collected retrospectively from a large tertiary referral revision arthroplasty unit’s database. Inclusion criteria included all patients who underwent TFA in our unit. Preoperative demographics, operative factors, and short- and long-term outcomes were collected for analysis. Outcome was defined using the Musculoskeletal Infection Society (MSIS) outcome reporting tool. Results. Overall, 38 TFAs were identified. The mean age was 73 years (42 to 80). All patients underwent TFA for non-oncological indications, most commonly as a consequence of infection (53%) and periprosthetic fracture (26%). The mean follow-up time was ten years (0 to 26); 63% of TFAs were considered a success based upon the MSIS outcome reporting tool. The mean time between TFA and death was 8.5 years (0.2 to 19.2), with two patients dying within one year of surgery. Within the cohort, 66% suffered at least one complication, dislocation being most common (37%); 55% of the total cohort required at least one subsequent operation. In total, 70% of TFAs undertaken for infection were considered infection-free at time of final follow-up. The percentage of mobile patients improved from 52% to 65% between pre- and postoperation, with all patients being able to at least transfer from bed to chair at time of final review. Conclusion. This study is the largest in the UK assessing the use of TFA in patients with bone loss secondary to non-oncological conditions. It demonstrates that TFA has a significant complication profile, however it is favourable in terms of mortality and rehabilitation when compared to amputation and disarticulation. Cite this article: Bone Joint J 2023;105-B(8):888–894


Bone & Joint Open
Vol. 4, Issue 8 | Pages 584 - 593
15 Aug 2023
Sainio H Rämö L Reito A Silvasti-Lundell M Lindahl J

Aims. Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. Methods. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures. Results. We were able to include 299 fractures in 291 patients. Altogether, 31/299 fractures (10%) developed nonunion. In the first analysis, pseudo-R. 2. was 0.27 and area under the receiver operating characteristic curve (AUC) was 0.81. BMI was the most important variable in the prediction. In the second analysis, pseudo-R. 2. was 0.06 and AUC was 0.67. Plate length was the most important variable in the prediction. Conclusion. The model including patient- and injury-related factors had moderate fit and predictive ability in the prediction of distal femur fracture nonunion leading to secondary surgery. BMI was the most important variable in prediction of nonunion. Surgeon-controlled factors had a minor role in prediction of nonunion. Cite this article: Bone Jt Open 2023;4(8):584–593


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1223 - 1230
1 Nov 2024
Dugdale EM Uvodich ME Pagnano MW Berry DJ Abdel MP Bedard NA

Aims. The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following total hip arthroplasty (THA). We sought to evaluate trends in BMI and complication rates of obese patients undergoing primary THA over the last 30 years. Methods. Through our institutional total joint registry, we identified 15,455 primary THAs performed for osteoarthritis from 1990 to 2019. Patients were categorized according to the World Health Organization (WHO) obesity classification and groups were trended over time. Cox proportional hazards regression analysis controlling for confounders was used to investigate the association between year of surgery and two-year risk of any reoperation, any revision, dislocation, periprosthetic joint infection (PJI), venous thromboembolism (VTE), and periprosthetic fracture. Regression was stratified by three separate groups: non-obese; WHO Class I and Class II (BMI 30 to 39 kg/m. 2. ); and WHO Class III patients (BMI ≥ 40 kg/m. 2. ). Results. There was a significant increase in the proportion of all obesity classes from 1990 to 2019, and the BMI values within each WHO class significantly increased over time. Risk of any reoperation did not change over time among non-obese or WHO Class I/II patients, but increased for WHO Class III patients (hazard ratio (HR) 1.04; p = 0.044). Risk of dislocation decreased over time for non-obese (HR 0.96; p < 0.001) and WHO Class I/II (HR 0.96; p = 0.002) patients, but did not change over time for WHO Class III (HR 0.94; p = 0.073) patients. Risks of any revision and PJI did not change over time for any group. Conclusion. The proportion of patients undergoing THA who are obese has increased dramatically at our institution between 1990 and 2019. Despite BMI values increasing within all WHO classes over time, two-year complication risks have remained stable or decreased in WHO Class I/II patients. However, continued efforts will be required to mitigate risks in the heaviest WHO Class III patients. Cite this article: Bone Joint J 2024;106-B(11):1223–1230


Bone & Joint Open
Vol. 5, Issue 5 | Pages 401 - 410
20 May 2024
Bayoumi T Burger JA van der List JP Sierevelt IN Spekenbrink-Spooren A Pearle AD Kerkhoffs GMMJ Zuiderbaan HA

Aims. The primary objective of this registry-based study was to compare patient-reported outcomes of cementless and cemented medial unicompartmental knee arthroplasty (UKA) during the first postoperative year. The secondary objective was to assess one- and three-year implant survival of both fixation techniques. Methods. We analyzed 10,862 cementless and 7,917 cemented UKA cases enrolled in the Dutch Arthroplasty Registry, operated between 2017 and 2021. Pre- to postoperative change in outcomes at six and 12 months’ follow-up were compared using mixed model analyses. Kaplan-Meier and Cox regression models were applied to quantify differences in implant survival. Adjustments were made for patient-specific variables and annual hospital volume. Results. Change from baseline in the Oxford Knee Score (OKS) and activity-related pain was comparable between groups. Adjustment for covariates demonstrated a minimally greater decrease in rest-related pain in the cemented group (β = -0.09 (95% confidence interval (CI) -0.16 to -0.01)). Cementless fixation was associated with a higher probability of achieving an excellent OKS outcome (> 41 points) (adjusted odds ratio 1.2 (95% CI 1.1 to 1.3)). The likelihood of one-year implant survival was greater for cemented implants (adjusted hazard ratio (HR) 1.35 (95% CI 1.01 to 1.71)), with higher revision rates for periprosthetic fractures of cementless implants. During two to three years’ follow-up, the likelihood of implant survival was non-significantly greater for cementless UKA (adjusted HR 0.64 (95% CI 0.40 to 1.04)), primarily due to increased revision rates for tibial loosening of cemented implants. Conclusion. Cementless and cemented medial UKA led to comparable improvement in physical function and pain reduction during the initial postoperative year, albeit with a greater likelihood of achieving excellent OKS outcomes after cementless UKA. Anticipated differences in early physical function and pain should not be a decisive factor in the choice of fixation technique. However, surgeons should consider the differences in short- and long-term implant survival when deciding which implant to use. Cite this article: Bone Jt Open 2024;5(5):401–410


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1261 - 1269
1 Jul 2021
Burger JA Zuiderbaan HA Sierevelt IN van Steenbergen L Nolte PA Pearle AD Kerkhoffs GMMJ

Aims. Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs. Methods. A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed. Results. In hospitals performing less than 100 cases per year, cemented mobile bearings reported comparable adjusted risks of revision as uncemented mobile bearings. However, in hospitals performing more than 100 cases per year, the adjusted risk of revision was higher for cemented mobile bearings compared to uncemented mobile bearings (hazard ratio 1.78 (95% confidence interval 1.34 to 2.35)). The adjusted risk of revision between cemented fixed bearing and uncemented mobile bearing was comparable, independent of annual hospital volume. In addition, 12.3% of uncemented mobile bearing, 20.3% of cemented mobile bearing, and 41.5% of uncemented fixed bearing revisions were for tibial component loosening. The figures for instability were 23.6%, 14.5% and 11.7%, respectively, and for periprosthetic fractures were 10.0%, 2.8%, and 3.5%. Bearing exchange was the type of revision in 40% of uncemented mobile bearing, 24.3% of cemented mobile bearing, and 5.3% cemented fixed bearing revisions. Conclusion. The findings of this study demonstrated improved survival with use of uncemented compared to cemented mobile bearings in medial UKA, only in those hospitals performing more than 100 cases per year. Cemented fixed bearings reported comparable survival results as uncemented mobile bearings, regardless of the annual hospital volume. The high rates of instability, periprosthetic fractures, and bearing exchange in uncemented mobile bearings emphasize the need for further research. Cite this article: Bone Joint J 2021;103-B(7):1261–1269


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1247 - 1253
1 Jul 2021
Slullitel PA Oñativia JI Zanotti G Comba F Piccaluga F Buttaro MA

Aims. There is a paucity of long-term studies analyzing risk factors for failure after single-stage revision for periprosthetic joint infection (PJI) following total hip arthroplasty (THA). We report the mid- to long-term septic and non-septic failure rate of single-stage revision for PJI after THA. Methods. We retrospectively reviewed 88 cases which met the Musculoskeletal Infection Society (MSIS) criteria for PJI. Mean follow-up was seven years (1 to 14). Septic failure was diagnosed with a Delphi-based consensus definition. Any reoperation for mechanical causes in the absence of evidence of infection was considered as non-septic failure. A competing risk regression model was used to evaluate factors associated with septic and non-septic failures. A Kaplan-Meier estimate was used to analyze mortality. Results. The cumulative incidence of septic failure was 8% (95% confidence interval (CI) 3.5 to 15) at one year, 13.8% (95% CI 7.6 to 22) at two years, and 19.7% (95% CI 12 to 28.6) at five and ten years of follow-up. A femoral bone defect worse than Paprosky IIIA (hazard ratio (HR) 13.58 (95% CI 4.86 to 37.93); p < 0.001) and obesity (BMI ≥ 30 kg/m. 2. ; HR 3.88 (95% CI 1.49 to 10.09); p = 0.005) were significantly associated with septic failure. Instability and periprosthetic fracture were the most common reasons for mechanical failure (5.7% and 4.5%, respectively). The cumulative incidence of aseptic failure was 2% (95% CI 0.4 to 7) at two years, 9% (95% CI 4 to 17) at five years, and 12% (95% CI 5 to 22) at ten years. A previous revision to treat PJI was significantly associated with non-septic failure (HR 9.93 (95% CI 1.77 to 55.46); p = 0.009). At the five-year timepoint, 93% of the patients were alive (95% CI 84% to 96%), which fell to 86% (95% CI 75% to 92%) at ten-year follow-up. Conclusion. Massive femoral bone loss was associated with greater chances of developing a further septic failure. All septic failures occurred within the first five years following the one-stage exchange. Surgeons should be aware of instability and periprosthetic fracture being potential causes of further aseptic revision surgery. Cite this article: Bone Joint J 2021;103-B(7):1247–1253


Bone & Joint Open
Vol. 4, Issue 5 | Pages 299 - 305
2 May 2023
Shevenell BE Mackenzie J Fisher L McGrory B Babikian G Rana AJ

Aims. Obesity is associated with an increased risk of hip osteoarthritis, resulting in an increased number of total hip arthroplasties (THAs) performed annually. This study examines the peri- and postoperative outcomes of morbidly obese (MO) patients (BMI ≥ 40 kg/m. 2. ) compared to healthy weight (HW) patients (BMI 18.5 to < 25 kg/m. 2. ) who underwent a THA using the anterior-based muscle-sparing (ABMS) approach. Methods. This retrospective cohort study observes peri- and postoperative outcomes of MO and HW patients who underwent a primary, unilateral THA with the ABMS approach. Data from surgeries performed by three surgeons at a single institution was collected from January 2013 to August 2020 and analyzed using Microsoft Excel and Stata 17.0. Results. This study compares 341 MO to 1,140 HW patients. Anaesthesia, surgery duration, and length of hospital stay was significantly lower in HW patients compared to MO. There was no difference in incidence of pulmonary embolism, periprosthetic fracture, or dislocation between the two groups. The rate of infection in MO patients (1.47%) was significantly higher than HW patients (0.14%). Preoperative patient-reported outcome measures (PROMs) show a significantly higher pain level in MO patients and a significantly lower score in functional abilities. Overall, six-week and one-year postoperative data show higher levels of pain, lower levels of functional improvement, and lower satisfaction scores in the MO group. Conclusion. The comorbidities of obesity are well studied; however, the implications of THA using the ABMS approach have not been studied. Our peri- and postoperative results demonstrate significant improvements in PROMs in MO patients undergoing THA. However, the incidence of deep infection was significantly higher in this group compared with HW patients. Cite this article: Bone Jt Open 2023;4(5):299–305


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 768 - 774
1 Jul 2023
Wooster BM Kennedy NI Dugdale EM Sierra RJ Perry KI Berry DJ Abdel MP

Aims. Contemporary outcomes of primary total hip arthroplasties (THAs) with highly cross-linked polyethylene (HXLPE) liners in patients with inflammatory arthritis have not been well studied. This study examined the implant survivorship, complications, radiological results, and clinical outcomes of THA in patients with inflammatory arthritis. Methods. We identified 418 hips (350 patients) with a primary diagnosis of inflammatory arthritis who underwent primary THA with HXLPE liners from January 2000 to December 2017. Of these hips, 68% had rheumatoid arthritis (n = 286), 13% ankylosing spondylitis (n = 53), 7% juvenile rheumatoid arthritis (n = 29), 6% psoriatic arthritis (n = 24), 5% systemic lupus erythematosus (n = 23), and 1% scleroderma (n = 3). Mean age was 58 years (SD 14.8), 66.3% were female (n = 277), and mean BMI was 29 kg/m. 2. (SD 7). Uncemented femoral components were used in 77% of cases (n = 320). Uncemented acetabular components were used in all patients. Competing risk analysis was used accounting for death. Mean follow-up was 4.5 years (2 to 18). Results. The ten-year cumulative incidence of any revision was 3%, and was highest in psoriatic arthritis patients (16%). The most common indications for the 15 revisions were dislocations (n = 8) and periprosthetic joint infections (PJI; n = 4, all on disease-modifying antirheumatic drugs (DMARDs)). The ten-year cumulative incidence of reoperation was 6.1%, with the most common indications being wound infections (six cases, four on DMARDs) and postoperative periprosthetic femur fractures (two cases, both uncemented femoral components). The ten-year cumulative incidence of complications not requiring reoperation was 13.1%, with the most common being intraoperative periprosthetic femur fracture (15 cases, 14 uncemented femoral components; p = 0.13). Radiological evidence of early femoral component subsidence was observed in six cases (all uncemented). Only one femoral component ultimately developed aseptic loosening. Harris Hip Scores substantially improved (p < 0.001). Conclusion. Contemporary primary THAs with HXLPE in patients with inflammatory arthritis had excellent survivorship and good functional outcomes regardless of fixation method. Dislocation, PJI, and periprosthetic fracture were the most common complications in this cohort with inflammatory arthritis. Cite this article: Bone Joint J 2023;105-B(7):768–774


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims. The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution. Methods. Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6). Results. Using revision for any reason as an endpoint, five-year survival for FB UKAs was 97.2% (95% CI 96.4 to 98.1) compared to 96.0% for MB (95% CI 94.1 to 97.9; p = 0.008). The FB group experienced fewer component revisions (14/2,315, 0.6% vs 12/684, 1.8%; p < 0.001) and conversion arthroplasties (38/2315, 1.6% vs 24/684, 3.5%; p < 0.001). A greater number of MB UKAs underwent revision due to osteoarthritis progression (FB = 21/2,315, 0.9% vs MB = 16/684, 2.3%; p = 0.003). In the MB group, 12 (1.8%) subjects experienced bearing dislocations which required revision surgery. There were 15 early periprosthetic tibia fractures (0.6%) in the FB group compared to 0 for MB (p = 0.035). Conclusion. In similar patient populations, FB UKAs demonstrated slightly higher survival than a commonly used MB design. Adverse event profiles differed by bearing type, with an increased risk of bearing dislocation and OA progression with MB designs, and early periprosthetic tibia fractures for FB designs. Cite this article: Bone Joint J 2024;106-B(9):916–923


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1113 - 1121
14 Sep 2020
Nantha Kumar N Kunutsor SK Fernandez MA Dominguez E Parsons N Costa ML Whitehouse MR

Aims. We conducted a systematic review and meta-analysis to compare the mortality, morbidity, and functional outcomes of cemented versus uncemented hemiarthroplasty in the treatment of intracapsular hip fractures, analyzing contemporary and non-contemporary implants separately. Methods. PubMed, Medline, EMBASE, CINAHL, and Cochrane Library were searched to 2 February 2020 for randomized controlled trials (RCTs) comparing the primary outcome, mortality, and secondary outcomes of function, quality of life, reoperation, postoperative complications, perioperative outcomes, pain, and length of hospital stay. Relative risks (RRs) and mean differences (with 95% confidence intervals (CIs)) were used as summary association measures. Results. A total of 18 studies corresponding to 16 non-overlapping RCTs with a total of 2,819 intracapsular hip fractures were included. Comparing contemporary cemented versus uncemented hemiarthroplasty, RRs (95% CIs) for mortality were 1.32 (0.44 to 3.99) perioperatively, 1.01 (0.48 to 2.10) at 30 days, and 0.90 (0.71 to 1.15) at one year. The use of contemporary cemented hemiarthroplasty reduced the risk of intra- and postoperative periprosthetic fracture. There were no significant differences in the risk of other complications, function, pain, and quality of life. There were no significant differences in perioperative outcomes except for increases in operating time and overall anaesthesia for contemporary cemented hemiarthroplasty with mean differences (95% CIs) of 6.67 (2.65 to 10.68) and 4.90 (2.02 to 7.78) minutes, respectively. The morbidity and mortality outcomes were not significantly different between non-contemporary cemented and uncemented hemiarthroplasty. Conclusion. There are no differences in the risk of mortality when comparing the use of contemporary cemented with uncemented hemiarthroplasty in the management of intracapsular hip fractures. Contemporary cemented hemiarthroplasty is associated with a substantially lower risk of intraoperative and periprosthetic fractures. Cite this article: Bone Joint J 2020;102-B(9):1113–1121


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 646 - 651
1 Jun 2019
Aggarwal VK Elbuluk A Dundon J Herrero C Hernandez C Vigdorchik JM Schwarzkopf R Iorio R Long WJ

Aims. A variety of surgical approaches are used for total hip arthroplasty (THA), all with reported advantages and disadvantages. A number of common complications can occur following THA regardless of the approach used. The purpose of this study was to compare five commonly used surgical approaches with respect to the incidence of surgery-related complications. Patients and Methods. The electronic medical records of all patients who underwent primary elective THA at a single large-volume arthroplasty centre, between 2011 and 2016, with at least two years of follow-up, were reviewed. After exclusion, 3574 consecutive patients were included in the study. There were 1571 men (44.0%) and 2003 women (56.0%). Their mean age and body mass index (BMI) was 63.0 years (. sd. 11.8) and 29.1 kg/m. 2. (. sd. 6.1), respectively. Data gathered included the age of the patient, BMI, the American Society of Anesthesiologists (ASA) score, estimated blood loss (EBL), length of stay (LOS), operating time, the presence of intra- or postoperative complications, type of complication, and the surgical approach. The approaches used during the study were posterior, anterior, direct lateral, anterolateral, and the northern approach. The complications that were recorded included prolonged wound drainage without infection, superficial infection, deep infection, dislocation, aseptic loosening, and periprosthetic fracture. Finally, the need for re-operation was recorded. Means were compared using analysis of variance (ANOVA) and Student’s t-tests where appropriate and proportions were compared using the chi-squared test. Results. A total of 248 patients had 263 complications related to the surgery, with an incidence of 6.94%. The anterior approach had the highest incidence of complications (8.5% (113/1329)) and the posterior approach had the lowest, at 5.85% (97/1657; p = 0.006). Most complications were due to deep infection (22.8%), periprosthetic fracture (22.4%), and prolonged wound drainage (21.3%). The rate of dislocation was 0.84% (14/1657) with the posterior approach and 1.28% (17/1329) with the anterior approach (p = 0.32). Conclusion. Overall, THA has a relatively low complication rate. However, the surgical approach plays a role in the incidence of complications. We found that the posterior approach had a significantly lower overall complication rate compared with the anterior approach, with an equal dislocation rate. Periprosthetic fracture and surgical site infection contributed most to the early complication rates. Cite this article: Bone Joint J 2019;101-B:646–651


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 361 - 364
15 Mar 2023
Vallier HA

Benefits of early stabilization of femoral shaft fractures, in mitigation of pulmonary and other complications, have been recognized over the past decades. Investigation into the appropriate level of resuscitation, and other measures of readiness for definitive fixation, versus a damage control strategy have been ongoing. These principles are now being applied to fractures of the thoracolumbar spine, pelvis, and acetabulum. Systems of trauma care are evolving to encompass attention to expeditious and safe management of not only multiply injured patients with these major fractures, but also definitive care for hip and periprosthetic fractures, which pose a similar burden of patient recumbency until stabilized. Future directions regarding refinement of patient resuscitation, assessment, and treatment are anticipated, as is the potential for data sharing and registries in enhancing trauma system functionality. Cite this article: Bone Joint J 2023;105-B(4):361–364


Bone & Joint 360
Vol. 13, Issue 2 | Pages 17 - 20
1 Apr 2024

The April 2024 Hip & Pelvis Roundup. 360. looks at: Impaction bone grafting for femoral revision hip arthroplasty with the Exeter stem; Effect of preoperative corticosteroids on postoperative glucose control in total joint replacement; Tranexamic acid in patients with a history of venous thromboembolism; Bisphosphonate use may be associated with an increased risk of periprosthetic hip fracture; A balanced approach: exploring the impact of surgical techniques on hip arthroplasty outcomes; A leap forward in hip arthroplasty: dual-mobility bearings reduce groin pain; A new perspective on complications: the link between blood glucose and joint infection risks


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1578 - 1585
1 Oct 2021
Abram SGF Sabah SA Alvand A Price AJ

Aims. To compare rates of serious adverse events in patients undergoing revision knee arthroplasty with consideration of the indication for revision (urgent versus elective indications), and compare these with primary arthroplasty and re-revision arthroplasty. Methods. Patients undergoing primary knee arthroplasty were identified in the national Hospital Episode Statistics (HES) between 1 April 1997 to 31 March 2017. Subsequent revision and re-revision arthroplasty procedures in the same patients and same knee were identified. The primary outcome was 90-day mortality and a logistic regression model was used to investigate factors associated with 90-day mortality and secondary adverse outcomes, including infection (undergoing surgery), pulmonary embolism, myocardial infarction, and stroke. Urgent indications for revision arthroplasty were defined as infection or fracture, and all other indications (e.g. loosening, instability, wear) were included in the elective indications cohort. Results. A total of 939,021 primary knee arthroplasty procedures were included (939,021 patients), of which 40,854 underwent subsequent revision arthroplasty, and 9,100 underwent re-revision arthroplasty. Revision surgery for elective indications was associated with a 90-day rate of mortality of 0.44% (135/30,826; 95% confidence interval (CI) 0.37 to 0.52) which was comparable to primary knee arthroplasty (0.46%; 4,292/939,021; 95% CI 0.44 to 0.47). Revision arthroplasty for infection was associated with a much higher mortality of 2.04% (184/9037; 95% CI 1.75 to 2.35; odds ratio (OR) 3.54; 95% CI 2.81 to 4.46), as was revision for periprosthetic fracture at 5.25% (52/991; 95% CI 3.94 to 6.82; OR 6.23; 95% CI 4.39 to 8.85). Higher rates of pulmonary embolism, myocardial infarction, and stroke were also observed in the infection and fracture cohort. Conclusion. Patients undergoing revision arthroplasty for urgent indications (infection or fracture) are at higher risk of mortality and serious adverse events in comparison to primary knee arthroplasty and revision arthroplasty for elective indications. These findings will be important for patient consent and shared decision-making and should inform service design for this patient cohort. Cite this article: Bone Joint J 2021;103-B(10):1578–1585


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 540 - 547
1 Jun 2024
Nandra RS Elnahal WA Mayne A Brash L McBryde CW Treacy RBC

Aims. The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years. Methods. The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken. Results. Overall implant survival was 83.50% (95% confidence interval (CI) 0.79 to 0.90) at 25 years, and the number at risk was 79. Survival in male patients at 25 years was 89.5% (95% CI 0.83 to 0.96) compared to 66.9% for female patients (95% CI 0.51 to 0.83). Ten additional failures occurred in the period of ten to 25 years. These involved an adverse reaction to metal debris in four patients, a periprosthetic femoral neck fracture affecting five patients, and aseptic loosening in one patient. The median chromium levels were 49.50 nmol/l (interquartile range (IQR) 34 to 70), and the median cobalt serum levels were 42 nmol/l (IQR 24.50 to 71.25). The median OHS at last follow-up was 35 (IQR 10 to 48). During the 25-year study period, 29 patients died. Patient survival at 25 years was 75.10% (95% CI 0.67 to 0.83). Conclusion. This study demonstrates that MoM hip resurfacing using the BHR provides a durable alternative to total hip arthroplasty (THA), particularly in younger male patients with osteoarthritis wishing to maintain a high level of function. These results compare favourably to the best results for THAs. Cite this article: Bone Joint J 2024;106-B(6):540–547


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1285 - 1291
1 Oct 2019
MacKenzie SA Ng RT Snowden G Powell-Bowns MFR Duckworth AD Scott CEH

Aims. Currently, periprosthetic fractures are excluded from the American Society for Bone and Mineral Research (ASBMR) definition of atypical femoral fracture (AFFs). This study aims to report on a series of periprosthetic femoral fractures (PFFs) that otherwise meet the criteria for AFFs. Secondary aims were to identify predictors of periprosthetic atypical femoral fractures (PAFFs) and quantify the complications of treatment. Patients and Methods. This was a retrospective case control study of consecutive patients with periprosthetic femoral fractures between 2007 and 2017. Two observers identified 16 PAFF cases (mean age 73.9 years (44 to 88), 14 female patients) and 17 typical periprosthetic fractures in patients on bisphosphonate therapy as controls (mean age 80.7 years (60 to 86, 13 female patients). Univariate and multivariate analysis was performed to identify predictors of PAFF. Management and complications were recorded. Results. Interobserver agreement for the PAFF classification was excellent (kappa = 0.944; p < 0.001). On univariate analysis compared with controls, patients with PAFFs had higher mean body mass indices (28.6 kg/m. 2. (. sd. 8.9) vs 21.5 kg/m. 2. (. sd. 3.3); p = 0.009), longer durations of bisphosphonate therapy (median 5.5 years (IQR 3.2 to 10.6) vs 2.4 years (IQR 1.0 to 6.4); p = 0.04), and were less likely to be on alendronate (50% vs 94%; p = 0.02) with an indication of secondary osteoporosis (19% vs 0%; p = 0.049). Duration of bisphosphonate therapy was an independent predictor of PAFF on multivariate analysis (R. 2. = 0.733; p = 0.05). Following primary fracture management, complication rates were higher in PAFFs (9/16, 56%) than controls (5/17, 29%; p = 0.178) with a relative risk of any complication following PAFF of 1.71 (95% confidence interval (CI) 0.77 to 3.8) and of reoperation 2.56 (95% CI 1.3 to 5.2). Conclusion. AFFs do occur in association with prostheses. Longer duration of bisphosphonate therapy is an independent predictor of PAFF. Complication rates are higher following PAFFs compared with typical PFFs, particularly of reoperation and infection. Cite this article: Bone Joint J 2019;101-B:1285–1291


Bone & Joint Research
Vol. 10, Issue 4 | Pages 250 - 258
1 Apr 2021
Kwak D Bang S Lee S Park J Yoo J

Aims. There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning. Methods. In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition. Results. Stress concentration was observed on the medial and lateral interfaces between the cortical bone and stem. With neutral stem insertion, mean stress over a region of interest was greater at the medial than lateral interface regardless of stem length, which increased as the stem shortened. Mean stress increased in the varus-inserted stems compared to the stems inserted neutrally, especially at the lateral interface in contact with the stem tip. The maximum stress was observed at the lateral interface in a varus-inserted short stem. All mean stresses were greater in stair-climbing condition than walking. Each micromotion was also greater in shorter stems and varus-inserted stems, and in stair-climbing condition. Conclusion. The stem should be inserted neutrally and stair-climbing movement should be avoided in the early postoperative period, in order to preserve early stability and reduce the possibility of thigh pain, especially when using a shorter stem. Cite this article: Bone Joint Res 2021;10(4):250–258


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 116 - 121
1 Jul 2021
Inoue D Grace TR Restrepo C Hozack WJ

Aims. Total hip arthroplasty (THA) using the direct anterior approach (DAA) is undertaken with the patient in the supine position, creating an opportunity to replace both hips under one anaesthetic. Few studies have reported simultaneous bilateral DAA-THA. The aim of this study was to characterize a cohort of patients selected for this technique by a single, high-volume arthroplasty surgeon and to investigate their early postoperative clinical outcomes. Methods. Using an institutional database, we reviewed 643 patients who underwent bilateral DAA-THA by a single surgeon between 1 January 2010 and 31 December 2018. The demographic characteristics of the 256 patients (39.8%) who underwent simultaneous bilateral DAA-THA were compared with the 387 patients (60.2%) who underwent staged THA during the same period of time. We then reviewed the length of stay, rate of discharge home, 90-day complications, and readmissions for the simultaneous bilateral group. Results. Patients undergoing simultaneous bilateral DAA-THA had a 3.5% transfusion rate, a 1.8 day mean length of stay, a 98.1% rate of discharge home, and low rates of 90-day infection (0.39%), dislocation (0.39%), periprosthetic fracture (0.77%), venous thromboembolism (0%), haematoma (0.39%), further surgery (0.77%), and readmission (0.77%). These patients were significantly younger (mean 58.2 years vs 62.5 years; p < 0.001), more likely to be male (60.3% vs 46.5%; p < 0.001), and with a trend towards having a lower mean BMI (27.8 kg/m. 2. vs 28.4 kg/m. 2. ; p = 0.071) than patients who underwent staged bilateral DAA-THA. Conclusion. Patients selected for simultaneous bilateral DAA-THA in a single surgeon’s practice had a 3% rate of postoperative transfusion and a low rate of complications, readmissions, and discharge to a rehabilitation facility. Simultaneous bilateral DAA-THA appears to be a reasonable and safe form of treatment for patients with bilateral symptomatic osteoarthritis of the hip when undertaken by an experienced arthroplasty surgeon with appropriate selection criteria. Cite this article: Bone Joint J 2021;103-B(7 Supple B):116–121


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 479 - 485
1 Mar 2021
Nugent M Young SW Frampton CM Hooper GJ

Aims. Joint registries typically use revision of an implant as an endpoint and report survival rates after a defined number of years. However, reporting lifetime risk of revision may be more meaningful, especially in younger patients. We aimed to assess lifetime risk of revision for patients in defined age groups at the time of primary surgery. Methods. The New Zealand Joint Registry (NZJR) was used to obtain rates and causes of revision for all primary total hip arthroplasties (THAs) performed between January 1999 and December 2016. The NZJR is linked to the New Zealand Registry of Births, Deaths and Marriages to obtain complete and accurate data. Patients were stratified by age at primary surgery, and lifetime risk of revision calculated according to age, sex, and American Society of Anesthesiologists (ASA) classification. The most common causes for revision were also analyzed for each age group. Results. The overall, ten-year implant survival rate was 93.6% (95% confidence interval (CI) 93.4% to 93.8%). It was lowest in the youngest age group (46 to 50 years), rising sequentially with increasing age to 97.5% in the oldest group (90 to 95 years). Lifetime risk of revision surgery was 27.6% (95% CI 27.3% to 27.8%) in those aged 46 to 50 years, decreasing with age to 1.1% (95% CI 0.0% to 5.8%) in those aged 90 to 95 years at the time of primary surgery. Higher ASA grades were associated with an increased lifetime risk of revision across all ages. The commonest causes for revision THA were aseptic loosening, infection, periprosthetic fracture, and dislocation. Conclusion. When counselling patients preoperatively, the lifetime risk of revision may be a more meaningful and useful measure of longer-term outcome than implant survival at defined time periods. This study highlights the considerably increased likelihood of subsequent revision surgery in younger age groups. Cite this article: Bone Joint J 2021;103-B(3):479–485


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims. Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants. Methods. A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed. Results. At mean 12.2 years (2 to 24) follow-up, HHS improved from mean 34.2 (20.8 to 60.5) to 75 (53.6 to 94.0; p < 0.001). Mean postoperative ROM was flexion 77° (50° to 95°), abduction 30° (10° to 40°), adduction 20° (5° to 25°), internal rotation 18° (2° to 30°), and external rotation 17° (5° to 30°). LLD improved from mean -3.36 cm (0 to 8) to postoperative mean -1.14 cm (0 to 4; p < 0.001). Postoperatively, 26 patients (68.4%) required the use of a walking aid. Complications included one (2.5%) dislocation, two (5.1%) partial sciatic nerve injuries, one (2.5%) deep periprosthetic joint infection, two instances of (5.1%) acetabular component aseptic loosening, two (5.1%) periprosthetic fractures, and ten instances of HO (40%), of which three (7.7%) were functionally limiting and required excision. Kaplan-Meier Survival was 97.1% (95% confidence interval (CI) 91.4% to 100%) at ten years and 88.2% (95% CI 70.96 to 100) at 15 years with implant revision for aseptic loosening as endpoint and 81.7% (95% CI 70.9% to 98.0%) at ten years and 74.2% (95% CI 55.6 to 92.8) at 15 years follow-up with implant revision for all cause failure as endpoint. Conclusion. The use of an optimal and consistent surgical technique and cementless implants can result in significant functional improvement, low complication rates, long-term implant survival, and high patient satisfaction following conversion of hip fusion to THA. The possibility of requiring a walking aid should be discussed with the patient before surgery. Cite this article: Bone Joint J 2021;103-B(7 Supple B):129–134


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1774 - 1781
1 Dec 2020
Clement ND Hall AJ Makaram NS Robinson PG Patton RFL Moran M Macpherson GJ Duckworth AD Jenkins PJ

Aims. The primary aim of this study was to assess the independent association of the coronavirus disease 2019 (COVID-19) on postoperative mortality for patients undergoing orthopaedic and trauma surgery. The secondary aim was to identify factors that were associated with developing COVID-19 during the postoperative period. Methods. A multicentre retrospective study was conducted of all patients presenting to nine centres over a 50-day period during the COVID-19 pandemic (1 March 2020 to 19 April 2020) with a minimum of 50 days follow-up. Patient demographics, American Society of Anesthesiologists (ASA) grade, priority (urgent or elective), procedure type, COVID-19 status, and postoperative mortality were recorded. Results. During the study period, 1,659 procedures were performed in 1,569 patients. There were 68 (4.3%) patients who were diagnosed with COVID-19. There were 85 (5.4%) deaths postoperatively. Patients who had COVID-19 had a significantly lower survival rate when compared with those without a proven SARS-CoV-2 infection (67.6% vs 95.8%, p < 0.001). When adjusting for confounding variables (older age (p < 0.001), female sex (p = 0.004), hip fracture (p = 0.003), and increasing ASA grade (p < 0.001)) a diagnosis of COVID-19 was associated with an increased mortality risk (hazard ratio 1.89, 95% confidence interval (CI) 1.14 to 3.12; p = 0.014). A total of 62 patients developed COVID-19 postoperatively, of which two were in the elective and 60 were in the urgent group. Patients aged > 77 years (odds ratio (OR) 3.16; p = 0.001), with increasing ASA grade (OR 2.74; p < 0.001), sustaining a hip (OR 4.56; p = 0.008) or periprosthetic fracture (OR 14.70; p < 0.001) were more likely to develop COVID-19 postoperatively. Conclusion. Perioperative COVID-19 nearly doubled the background postoperative mortality risk following surgery. Patients at risk of developing COVID-19 postoperatively (patients > 77 years, increasing morbidity, sustaining a hip or periprosthetic fracture) may benefit from perioperative shielding. Cite this article: Bone Joint J 2020;102-B(12):1774–1781


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 921 - 926
1 Jul 2017
Märdian S Perka C Schaser K Gruner J Scheel F Schwabe P

Aims. Periprosthetic fracture is a significant complication of total hip and knee arthroplasty. This study aimed to describe the survival of patients sustaining periprosthetic femoral fractures and compare this with that of the general population, as well as to identify the factors that influence survival. Patients and Methods. A total of 151 patients (women: men 116:35, mean age 74.6 years, standard deviation 11.5) that sustained a periprosthetic fracture between January 2005 and October 2012 were retrospectively analysed. Epidemiological data, comorbidities, type of surgical management, type of implant, and mortality data were studied. Results. The mean survival time was 77 months (95% confidence interval 71 to 84; numbers at risk: 73) and was lower than that of the general population. The risk analyses showed that previous cardiac disease, particularly ischaemic heart disease, cardiac arrhythmias, and heart failure, age over 75 years and American Society of Anesthesiologists (ASA) scores above 3 were associated with a significantly higher mortality. Conclusions. Periprosthetic fractures carry a high risk of post-operative mortality. Our data demonstrate that advanced age (> 75 years) and previous cardiac disease are associated with a significantly higher risk of mortality. The ASA score is an appropriate instrument for risk stratification. Pre-operative cardiac status should be optimised before surgery. Cite this article: Bone Joint J 2017;99-B:921–6


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 811 - 821
1 Jul 2020
You D Sepehri A Kooner S Krzyzaniak H Johal H Duffy P Schneider P Powell J

Aims. Dislocation is the most common indication for further surgery following total hip arthroplasty (THA) when undertaken in patients with a femoral neck fracture. This study aimed to assess the complication rates of THA with dual mobility components (THA-DMC) following a femoral neck fracture and to compare outcomes between THA-DMC, conventional THA, and hemiarthroplasty (HA). Methods. We performed a systematic review of all English language articles on THA-DMC published between 2010 and 2019 in the MEDLINE, EMBASE, and Cochrane databases. After the application of rigorous inclusion and exclusion criteria, 23 studies dealing with patients who underwent treatment for a femoral neck fracture using THA-DMC were analyzed for the rate of dislocation. Secondary outcomes included reoperation, periprosthetic fracture, infection, mortality, and functional outcome. The review included 7,189 patients with a mean age of 77.8 years (66.4 to 87.6) and a mean follow-up of 30.9 months (9.0 to 68.0). Results. THA-DMC was associated with a significantly lower dislocation rate compared with both THA (OR 0.26; 95% CI 0.08 to 0.79) and HA (odds ratio (OR) 0.27; 95% confidence interval (CI) 0.15 to 0.50). The rate of large articulations and of intraprosthetic dislocation was 1.5% (n = 105) and 0.04% (n = 3) respectively. Conclusion. THA-DMC when used in patients with a femoral neck fracture is associated with a lower dislocation rate compared with conventional arthroplasty options. There was no increase in the rates of other complication when THA-DMC was used. Future cost analysis and prospective, comparative studies are required to assess the potential benefit of using THA-DMC in these patients. Cite this article: Bone Joint J 2020;102-B(7):811–821


Aims. To evaluate the hypothesis that failed osteosynthesis of periprosthetic Vancouver type B1 fractures can be treated successfully with stem revision using a transfemoral approach and a cementless, modular, tapered revision stem with reproducible rates of fracture healing, stability of the revision stem, and clinically good results. Patients and Methods. A total of 14 patients (11 women, three men) with a mean age of 72.4 years (65 to 90) undergoing revision hip arthroplasty after failed osteosynthesis of periprosthetic fractures of Vancouver type B1 were treated using a transfemoral approach to remove the well-fixed stem before insertion of a modular, fluted titanium stem which obtained distal fixation. These patients were clinically and radiologically followed up for a mean 52.2 months (24 to 144). Results. After a mean of 15.5 weeks (standard deviation (. sd. ) 5.7) all fractures had healed. No stems subsided and bony-ingrowth fixation had occurred according to the classification of Engh et al. The mean Harris Hip Score increased from a pre-operative score of 22.2 points (. sd. 9.7) to 81.5 points (. sd. 16.8) 24 months post-operatively. All hips had obtained an excellent result according to the classification of Beals and Tower. Conclusions. The technique described here for stem revision provides reproducibly good results in the treatment of failed osteosynthesis for Vancouver types B1 periprosthetic fractures of the hip. Cite this article: Bone Joint J 2017;99-B(4 Supple B):11–16


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 959 - 964
1 Jul 2020
Malik AT Li M Khan SN Alexander JH Li D Scharschmidt TJ

Aims. Currently, the US Center for Medicaid and Medicare Services (CMS) has been testing bundled payments for revision total joint arthroplasty (TJA) through the Bundled Payment for Care Improvement (BPCI) programme. Under the BPCI, bundled payments for revision TJAs are defined on the basis of diagnosis-related groups (DRGs). However, these DRG-based bundled payment models may not be adequate to account appropriately for the varying case-complexity seen in revision TJAs. Methods. The 2008-2014 Medicare 5% Standard Analytical Files (SAF5) were used to identify patients undergoing revision TJA under DRG codes 466, 467, or 468. Generalized linear regression models were built to assess the independent marginal cost-impact of patient, procedural, and geographic characteristics on 90-day costs. Results. A total of 9,263 patients (DRG-466 = 838, DRG-467 = 4,573, and DRG-468 = 3,842) undergoing revision TJA from 2008 to 2014 were included in the study. Undergoing revision for a dislocation (+$1,221), periprosthetic fracture (+$4,454), and prosthetic joint infection (+$5,268) were associated with higher 90-day costs. Among comorbidities, malnutrition (+$10,927), chronic liver disease (+$3,894), congestive heart failure (+$3,292), anaemia (+$3,149), and coagulopathy (+$2,997) had the highest marginal cost-increase. The five US states with the highest 90-day costs were Alaska (+$14,751), Maryland (+$13,343), New York (+$7,428), Nevada (+$6,775), and California (+$6,731). Conclusion. Under the proposed DRG-based bundled payment methodology, surgeons would be reimbursed the same amount of money for revision TJAs, regardless of the indication (periprosthetic fracture, prosthetic joint infection, mechanical loosening) and/or patient complexity. Cite this article: Bone Joint J 2020;102-B(7):959–964


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 664 - 670
1 Jun 2020
Wyatt MC Kunutsor SK Beswick AD Whitehouse MR Kieser DC

Aims. There is inconsistent evidence on whether prior spinal fusion surgery adversely impacts outcomes following total hip arthroplasty (THA). We conducted a systematic review and meta-analysis to assess the association between pre-existing spinal fusion surgery and the rate of complications following primary THA. Methods. We searched MEDLINE, Embase, Web of Science, and Cochrane Library up to October 2019 for randomized controlled trials (RCTs) and observational studies comparing outcomes of dislocation, revision, or reasons for revision in patients following primary THA with or without pre-existing spinal fusion surgery. Furthermore, we compared short (two or less levels) or long (three or more levels) spinal fusions to no fusion. Summary measures of association were relative risks (RRs) (with 95% confidence intervals (CIs)). Results. We identified ten articles corresponding to nine unique observational studies comprising of 1,992,366 primary THAs. No RCTs were identified. There were 32,945 cases of spinal fusion and 1,752,362 non-cases. Comparing prior spinal fusion versus no spinal fusion in primary THA, RRs (95% CI) for dislocation was 2.23 (1.81 to 2.74; seven studies), revision 2.14 (1.63 to 2.83; five studies), periprosthetic joint infection 1.71 (1.53 to 1.92; four studies), periprosthetic fracture 1.52 (1.28 to 1.81; three studies), aseptic loosening 1.76 (1.54 to 2.01; three studies), and any complications 2.82 (1.37 to 5.80; three studies) were identified. Both short and long spinal fusions, when compared with no fusion, were associated dislocation, revision, or reasons for revision. Conclusions. Patients with prior spinal fusion are at risk of adverse events following primary THA. Measures that reduce the risk of these complications should be considered in this high-risk population when undergoing primary THA. These patients should also be counselled appropriately around their risks of undergoing THA. Cite this article: Bone Joint J 2020;102-B(6):664–670


Bone & Joint Open
Vol. 1, Issue 12 | Pages 743 - 748
1 Dec 2020
Mahon J McCarthy CJ Sheridan GA Cashman JP O'Byrne JM Kenny P

Aims. The Exeter V40 cemented femoral stem was first introduced in 2000. The largest single-centre analysis of this implant to date was published in 2018 by Westerman et al. Excellent results were reported at a minimum of ten years for the first 540 cases performed at the designer centre in the Exeter NHS Trust, with stem survivorship of 96.8%. The aim of this current study is to report long-term outcomes and survivorship for the Exeter V40 stem in a non-designer centre. Methods. All patients undergoing primary total hip arthroplasty using the Exeter V40 femoral stem between 1 January 2005 and 31 January 2010 were eligible for inclusion. Data were collected prospectively, with routine follow-up at six to 12 months, two years, five years, and ten years. Functional outcomes were assessed using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores. Outcome measures included data on all components in situ beyond ten years, death occurring within ten years with components in situ, and all-cause revision surgery. Results. A total of 829 stems in 745 patients were included in the dataset; 155 patients (20.8%) died within ten years, and of the remaining 664 stems, 648 stems (97.6%) remained in situ beyond ten years. For the 21 patients (2.5%) undergoing revision surgery, 16 femoral stems (1.9%) were revised and 18 acetabular components (2.2%) were revised. Indications for revision in order of decreasing frequency were infection (n = 6), pain (n = 6), aseptic component loosening (n = 3), periprosthetic fracture (n = 3), recurrent dislocation (n = 2), and noise production (ceramic-on-ceramic squeak) (n = 1). One patient was revised for aseptic stem loosening. The mean preoperative WOMAC score was 61 (SD 15.9) with a mean postoperative score of 20.4 (SD 19.3) (n = 732; 88.3%). Conclusion. The Exeter V40 cemented femoral stem demonstrates excellent functional outcomes and survival when used in a high volume non-designer centre. Outcomes are comparable to those of its serially validated predecessor, the Exeter Universal stem. Cite this article: Bone Jt Open 2020;1-12:743–748


Bone & Joint Open
Vol. 2, Issue 1 | Pages 33 - 39
14 Jan 2021
McLaughlin JR Lee KR Johnson MA

Aims. We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. Methods. A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one. Results. Two femoral components (3.2%) required revision. One stem was revised secondary to a periprosthetic fracture one year postoperatively and one was revised for late sepsis. No femoral component was revised for aseptic loosening. Six acetabular components had required revision, five for aseptic loosening. One additional acetabular component was revised for sepsis. Radiologically, all femoral components remained well fixed. One acetabular was judged loose by radiological criteria. The mean Harris Hip Score improved from 46 points (30 to 67) preoperatively to 89 points (78 to 100) at final follow-up. With revision for aseptic loosening as the endpoint, survival of the acetabular component was 95% (95% confidence interval (CI) 90 to 98) at 25 years. Femoral component survival was 100%. Conclusion. The most significant finding of this report was the low prevalence of aseptic loosening and revision of the femoral component at a mean follow-up of 22 years. A second important finding was the survival of over 90% of the hemispheric threaded ring acetabular components. While these shells remain controversial, in this series they performed well. Cite this article: Bone Jt Open 2021;2(1):33–39


Bone & Joint Research
Vol. 11, Issue 5 | Pages 270 - 277
6 May 2022
Takegami Y Seki T Osawa Y Imagama S

Aims. Periprosthetic hip fractures (PPFs) after total hip arthroplasty are difficult to treat. Therefore, it is important to identify modifiable risk factors such as stem selection to reduce the occurrence of PPFs. This study aimed to clarify differences in fracture torque, surface strain, and fracture type analysis between three different types of cemented stems. Methods. We conducted biomechanical testing of bone analogues using six cemented stems of three different types: collarless polished tapered (CPT) stem, Versys Advocate (Versys) stem, and Charnley-Marcel-Kerboull (CMK) stem. Experienced surgeons implanted each of these types of stems into six bone analogues, and the analogues were compressed and internally rotated until failure. Torque to fracture and fracture type were recorded. We also measured surface strain distribution using triaxial rosettes. Results. There was a significant difference in fracture torque between the three stem types (p = 0.036). Particularly, the median fracture torque for the CPT stem was significantly lower than that for the CMK stem (CPT vs CMK: 164.5 Nm vs 200.5 Nm; p = 0.046). The strain values for the CPT stem were higher than those for the other two stems at the most proximal site. The fracture pattern of the CPT and Versys stems was Vancouver type B, whereas that of the CMK stem was type C. Conclusion. Our study suggested that the cobalt-chromium alloy material, polished surface finish, acute-square proximal form, and the absence of a collar may be associated with lower fracture torque, which may be related to PPF. Cite this article: Bone Joint Res 2022;11(5):270–277


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 11 - 16
1 Jan 2020
Parker MJ Cawley S

Aims. Debate continues about whether it is better to use a cemented or uncemented hemiarthroplasty to treat a displaced intracapsular fracture of the hip. The aim of this study was to attempt to resolve this issue for contemporary prostheses. Methods. A total of 400 patients with a displaced intracapsular fracture of the hip were randomized to receive either a cemented polished tapered stem hemiarthroplasty or an uncemented Furlong hydroxyapatite-coated hemiarthroplasty. Follow-up was conducted by a nurse blinded to the implant at set intervals for up to one year from surgery. Results. A total of 115 patients died in the year after surgery. There was a tendency towards a slightly higher mortality in those treated with the uncemented prosthesis after one year (64 vs 51; p = 0.18). For the survivors, there was no significant difference in pain score at any of the time intervals. Patients treated using the cemented hemiarthroplasty recovered mobility better than those treated with the uncemented hemiarthroplasty (mean decrease in mobility score at one year: 1.7 vs 1.1, SD 1.9; p = 0.008). There was a tendency to more periprosthetic fractures in the uncemented group (five vs two cases; p = 0.45), but overall the need for further surgery was similar in both groups (nine vs seven cases). There were four perioperative deaths in the cemented group. Conclusion. These results indicate that a contemporary cemented hemiarthroplasty gives better results than an uncemented hemiarthroplasty for patients with a displaced intracapsular fracture of the hip. When the condition of the patient permits, a cemented hemiarthroplasty should be used. Cite this article: Bone Joint J. 2020;102-B(1):11–16


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 107 - 115
1 Jun 2020
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP

Aims. Metaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system. Methods. We reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m. 2. (18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6). Results. Survivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully. Conclusion. Novel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 191 - 197
1 Feb 2020
Gabor JA Padilla JA Feng JE Schnaser E Lutes WB Park KJ Incavo S Vigdorchik J Schwarzkopf R

Aims. Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications. Methods. A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m. 2. (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year). Results. There were eight intraoperative complications (4.9%), six of which were intraoperative fractures; none occurred during stem insertion. Six hips (3.7%) underwent re-revision within one year; only one procedure involved removal of the prosthesis due to infection. Mean total subsidence at latest follow-up was 1.64 mm (SD 2.47). Overall, 17 of 144 stems (11.8%) on which measurements could be performed had >5 mm of subsidence, and 3/144 (2.1%) had >10 mm of subsidence within one year. A univariate regression analysis found that additional subsidence after three months was minimal. A multivariate regression analysis found that subsidence was not significantly associated with periprosthetic fracture as an indication for surgery, the presence of an extended trochanteric osteotomy (ETO), Paprosky classification of femoral bone loss, stem length, or type of procedure performed (i.e. full revision vs conversion/primary). Conclusion. Advances in implant design, improved trials, a range of stem lengths and diameters, and high offset options mitigate concerns of early subsidence and dislocation with monolithic TFTS, making them a valuable option for femoral revision. Cite this article: Bone Joint J 2020;102-B(2):191–197


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 116 - 122
1 Jun 2020
Bedard NA Cates RA Lewallen DG Sierra RJ Hanssen AD Berry DJ Abdel MP

Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in relation to implant fixation. Moreover, radiographs revealed incorporation of the bone graft and biological fixation of the cone. While long-term follow-up will be important, this technique provides an excellent option for the management of complex revision TKAs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):116–122


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1319 - 1323
3 Oct 2020
Khatun F Gill DF Atrey A Porteous M

Aims. We present the results, in terms of survival, clinical outcome, and radiological appearance at 20 years, in a cohort of 225 cemented Exeter Universal femoral components (Stryker, Newbury, UK) implanted in 207 patients, at a district general hospital. Methods. All patients in this study had a total hip arthroplasty (THA) using an Exeter Universal femoral component with a cemented (n = 215) or cementless (n = 10) acetabular component. Clinical and radiological data were collected prospectively at one year, five years, and every five years thereafter. Patients lost to radiological and clinical follow-up (five) were cross-referenced with National Joint Registry (NJR) data and general practitioner (GP) records to assess whether they had undergone revision for any reason. Results. During this period of study 144 patients (157 hips) died (69.78%). Two patients were lost to follow-up, leaving 61 patients (66 hips) available for review (29.33%). Of the 225 hips, three underwent revision for femoral failure with osteolysis. One underwent femoral component revision for treatment of a periprosthetic fracture. Eight underwent revision of the acetabular component only for loosening. Two hips had both components revised, when components were found to be loose at time of revision for acetabular loosening, though no radiological femoral osteolysis. Two patients underwent revision for infection. Using femoral loosening as an endpoint, the survival of the Exeter Universal femoral component was 98.7% (n = 220, 95% confidence interval (CI) 96.1% to 100%) at 20 to 22 years. Survival with an endpoint of revision for any reason was 92.6% (n = 209, 95% CI 89.4 to 95.55), with a ‘worst-case scenario’ (considering two patients lost to follow-up to have failed), the overall survival rate was 91.7% (n = 207, 95% CI 87.8 to 95.9) at 20 to 22 years. Conclusion. Our results confirm excellent long-term results for the cemented Exeter Universal femoral componentimplanted outside of the originating centre. Cite this article: Bone Joint J 2020;102-B(10):1319–1323


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1447 - 1458
1 Nov 2019
Chatziagorou G Lindahl H Kärrholm J

Aims. We investigated patient characteristics and outcomes of Vancouver type B periprosthetic fractures treated with femoral component revision and/or osteosynthesis. Patients and Methods. The study utilized data from the Swedish Hip Arthroplasty Register (SHAR) and information from patient records. We included all primary total hip arthroplasties (THAs) performed in Sweden since 1979, and undergoing further surgery due to Vancouver type B periprosthetic femoral fracture between 2001 and 2011. The primary outcome measure was any further reoperation between 2001 and 2013. Cross-referencing with the National Patient Register was performed in two stages, in order to identify all surgical procedures not recorded on the SHAR. Results. Out of 1381 Vancouver type B fractures that fulfilled the inclusion criteria, 257 underwent further reoperation by the end of 2013. Interprosthetic and Type B1 fractures had a higher risk for reoperation. For B1 fractures, the rate of reoperation did not differ (p = 0.322) after use of conventional (26%) or locking plate osteosynthesis (19%). No significant differences were observed between cemented, cementless monoblock, and cementless modular revision components for the treatment of type B2 and B3 fractures. Conclusion. In this country-specific study, the choice of locking or conventional plates for the treatment of type B1, and cemented or cementless femoral components fixation for B2 and B3 fractures, had no significant influence on risk for reoperation. Interprosthetic fractures adversely affected the outcome of treatment of type B fractures. Differences in the patient characteristics of the compared groups were observed. Cite this article: Bone Joint J 2019;101-B:1447–1458


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1199 - 1208
1 Oct 2019
Lamb JN Matharu GS Redmond A Judge A West RM Pandit HG

Aims. We compared implant and patient survival following intraoperative periprosthetic femoral fractures (IOPFFs) during primary total hip arthroplasty (THA) with matched controls. Patients and Methods. This retrospective cohort study compared 4831 hips with IOPFF and 48 154 propensity score matched primary THAs without IOPFF implanted between 2004 and 2016, which had been recorded on a national joint registry. Implant and patient survival rates were compared between groups using Cox regression. Results. Ten-year stem survival was worse in the IOPFF group (p < 0.001). Risk of revision for aseptic loosening increased 7.2-fold following shaft fracture and almost 2.8-fold after trochanteric fracture (p < 0.001). Risk of periprosthetic fracture of the femur revision increased 4.3-fold following calcar-crack and 3.6-fold after trochanteric fracture (p < 0.01). Risk of instability revision was 3.6-fold after trochanteric fracture and 2.4-fold after calcar crack (p < 0.001). Risk of 90-day mortality following IOPFF without revision was 1.7-fold and 4.0-fold after IOPFF with early revision surgery versus uncomplicated THA (p < 0.001). Conclusion. IOPFF increases risk of stem revision and mortality up to ten years following surgery. The risk of revision depends on IOPFF subtype and mortality risk increases with subsequent revision surgery. Surgeons should carefully diagnose and treat IOPFF to minimize fracture progression and implant failure. Cite this article: Bone Joint J 2019;101-B:1199–1208


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1144 - 1150
1 Sep 2019
Tsuda Y Fujiwara T Sree D Stevenson JD Evans S Abudu A

Aims. The aim of this study was to report the results of custom-made endoprostheses with extracortical plates plus or minus a short, intramedullary stem aimed at preserving the physis after resection of bone sarcomas in children. Patients and Methods. Between 2007 and 2017, 18 children aged less than 16 years old who underwent resection of bone sarcomas, leaving ≤ 5 cm of bone from the physis, and reconstruction with a custom-made endoprosthesis were reviewed. Median follow-up was 67 months (interquartile range 45 to 91). The tumours were located in the femur in 11 patients, proximal humerus in six, and proximal tibia in one. Results. The five-year overall survival rate was 78%. No patient developed local recurrence. The five-year implant survival rate was 79%. In all, 11 patients (61%) developed a complication. Seven patients (39%) required further surgery to treat the complications. Implant failures occurred in three patients (17%) including one patient with aseptic loosening and two patients with implant or periprosthetic fracture. The preserved physis continued to grow at mean 3.3 cm (0 to 14). The mean Musculoskeletal Society score was 88% (67% to 97%). Conclusion. Custom-made endoprostheses that aim to preserve the physis are a safe and effective option for preserving physeal growth, limb length, and joint function with an acceptable rate of complications. Cite this article: Bone Joint J 2019;101-B:1144–1150


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1002 - 1009
1 Aug 2018
Westerman RW Whitehouse SL Hubble MJW Timperley AJ Howell JR Wilson MJ

Aims. The aim of this study was to report the initial results of the Exeter V40 stem, which became available in 2000. Patients and Methods. A total of 540 total hip arthroplasties (THAs) were performed in our unit using this stem between December 2000 and May 2002. Our routine protocol is to review patients postoperatively and at one, five, and ten years following surgery. Results. A total of 145 patients (26.9%) died before ten years and of the remaining 395 stems, 374 (94.7%) remain in situ. A total of 21 well-fixed stems (5.3%) were revised. Ten were exchanged using a cement-in-cement technique to facilitate acetabular revision. Three were revised for infection, one for instability, one for fracture of the stem, and six following a periprosthetic fracture. An additional 16 acetabular components (4.1%) were revised; five for aseptic loosening and 11 for instability. There were no revisions for aseptic loosening of the stem, and no evidence of aseptic loosening in any hip. The fate of every stem is known and all patients remain under review. Survivorship, with revision of the stem for aseptic loosening as the endpoint, was 100%. At 13.5 years, the Kaplan–Meier survival rate for all-cause revision of the stem was 96.8% (95% confidence interval (CI) 94.8 to 98.8) and all-cause revision (including acetabular revision, infection, and instability) was 91.2% (95% CI 88.3 to 94.1). Conclusion. No stem was revised for aseptic loosening in this series. The contemporary Exeter V40 stem continues to perform well, and survival has remained comparable with that of the Exeter Universal stem. Cite this article: Bone Joint J 2018;100-B:1002–9


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims. Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA. Patients and Methods. We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10). Results. Six patients (22%) developed complications requiring further revision surgery, at a mean of 1.7 years (0.1 to 5.3) postoperatively. The indication for further revision was dislocation in two, glenoid loosening in one, fracture of the humeral component in one, disassociation of the glenosphere in one, and infection in one. The five-year survival free of further revision was 85%. Five additional RSAs developed complications that did not need surgery, including dislocation in three and periprosthetic fracture in two. Overall, patients who did not require further revision had excellent pain relief, and significant improvements in elevation and external rotation of the shoulder (p < 0.01). The mean postoperative American Shoulder and Elbow Surgeons (ASES), and simple shoulder test (SST) scores were 66 and 7, respectively. Radiological results were available in 26 patients (96.3%) at a mean of 4.3 years (1.5 to 9.5). At the most recent follow-up, six patients (23%) had glenoid lucency, which were classified as grade III or higher in three (12%). Smokers had a significantly increased risk of glenoid lucency (p < 0.01). Conclusion. Revision RSA, when used to salvage a failed primary RSA, can be a successful procedure. At intermediate follow-up, survival rates are reasonable, but dislocation and glenoid lucency remain a concern, particularly in smokers. Cite this article: Bone Joint J 2018;100-B:1493–98


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims. Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). Patients and Methods. A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m. 2. (17.3 to 66.4). Results. Greater tuberosity stress shielding was noted in 14 shoulders (two TSA and 12 RSA) and was graded as mild in nine, moderate in two, and severe in three. Medial calcar resorption was noted in 23 shoulders (seven TSA and 16 RSA), and was graded as mild in 21 and moderate in two. No humeral components were revised for loosening or considered to be loose radiologically. Nine shoulders underwent reoperation for infection (n = 3), fracture of the humeral tray (n = 2), aseptic glenoid loosening (n = 1), and instability (n = 3). No periprosthetic fractures occurred. Conclusion. Implantation of this particular short cementless humeral component at the time of TSA or RSA was associated with a low rate of adverse radiological findings on the humeral side at mid-term follow-up. Our data do not raise any concerns regarding the use of a short stem in TSA or RSA. Cite this article: Bone Joint J 2019;101-B:610–614


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 220 - 223
1 Mar 2024
Kayani B Luo TD Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 879 - 883
1 Sep 2024
Kayani B Staats K Haddad FS


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims. The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal. Patients and Methods. A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years. Results. At a mean follow-up of three years (1.5 to 5.7), no local or systemic symptoms of hypersensitivity to metal were observed. One patient underwent revision surgery to a bicondylar prosthesis due to a tibial periprosthetic fracture resulting in a survival rate of 98.8% (95% confidence interval (CI) 91.7 to 99.8; number at risk, 28) at three years with the endpoint of revision for any reason and a survival rate of 97.6% (95% CI 90.6 to 99.3; number at risk, 29) for the endpoint of all reoperations. Clinical outcome was good to excellent with a mean Oxford Knee Score of 42.5 (. sd. 2.5; 37 to 48). Conclusion. This study is the first demonstrating clinical results and survival analysis of UKA using a CoCr alloy in patients with a history of metal hypersensitivity. Functional outcome and survivorship are on a high-level equivalent to those reported for UKA in patients without a history of metal hypersensitivity. No serious local or systemic symptoms of metal hypersensitivity could be detected, and no revision surgery was performed due to an adverse reaction to metal ions


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 593 - 601
1 Jun 2023
Scott CEH Yapp LZ Howard T Patton JT Moran M

Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further peri-implant fracture. The surgical approach to these fractures, the associated soft-tissue handling, and exposure of the fracture are key elements in minimizing the high rate of complications. This annotation describes the approaches to the femur that can be used to facilitate the surgical management of peri- and interprosthetic fractures of the femur at all levels using either modern methods of fixation or revision arthroplasty.

Cite this article: Bone Joint J 2023;105-B(6):593–601.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 47 - 55
1 Jan 2023
Clement ND Avery P Mason J Baker PN Deehan DJ

Aims

The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge knee arthroplasty (HKA) when used for first-time knee revision surgery and factors that were associated with re-revision.

Methods

Patient demographic details, BMI, American Society of Anesthesiologists (ASA) grade, indication for revision, surgical approach, surgeon grade, implant type (fixed and rotating), time of revision from primary implantation, and re-revision if undertaken were obtained from the National Joint Registry data for England, Wales, Northern Ireland, and the Isle of Man over an 18-year period (2003 to 2021).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1293 - 1300
1 Nov 2024
O’Malley O Craven J Davies A Sabharwal S Reilly P

Aims

Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA.

Methods

MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 923 - 931
4 Dec 2023
Mikkelsen M Rasmussen LE Price A Pedersen AB Gromov K Troelsen A

Aims

The aim of this study was to describe the pattern of revision indications for unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) and any change to this pattern for UKA patients over the last 20 years, and to investigate potential associations to changes in surgical practice over time.

Methods

All primary knee arthroplasty surgeries performed due to primary osteoarthritis and their revisions reported to the Danish Knee Arthroplasty Register from 1997 to 2017 were included. Complex surgeries were excluded. The data was linked to the National Patient Register and the Civil Registration System for comorbidity, mortality, and emigration status. TKAs were propensity score matched 4:1 to UKAs. Revision risks were compared using competing risk Cox proportional hazard regression with a shared γ frailty component.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims

Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty.

Methods

Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1611 - 1619
1 Dec 2016
Wilson MJ Hook S Whitehouse SL Timperley AJ Gie GA

Aims. Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time. . Patients and Methods. Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died. Results. There were 76 further revisions (10.8%) involving the stem; seven for aseptic loosening, 23 for periprosthetic fracture, 24 for infection, one for malposition, one for fracture of the stem and 19 cement-in-cement exchanges of the stem during acetabular revision. The 20-year survival rate for the entire series was 98.8% (95% confidence interval (CI) 97.8 to 99.8) with aseptic loosening as the endpoint, and 87.7% (95% CI 82.8 to 92.6) for revision for any reason. Survival improved with the evolution of the technique, although this was not statistically significant due to the overall low rate of further revision. Conclusion. This is the largest series of revision total hip arthroplasties with femoral impaction grafting, and the results support the continued use of this technique. Cite this article: Bone Joint J 2016;98-B:1611–19


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 130 - 136
1 Mar 2024
Morlock M Perka C Melsheimer O Kirschbaum SM

Aims

Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients.

Methods

A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 20 - 23
1 Apr 2024

The April 2024 Knee Roundup360 looks at: Challenging the status quo: re-evaluating the impact of obesity on unicompartmental knee arthroplasty outcomes; Timing matters: the link between ACL reconstruction delays and cartilage damage; Custom fit or off the shelf: evaluating patient outcomes in tailored versus standard knee replacements; Revolutionizing knee replacement: a comparative study on robotic-assisted and computer-navigated techniques; Pre-existing knee osteoarthritis and severe joint depression are associated with the need for total knee arthroplasty after tibial plateau fracture in patients aged over 60 years; Modern digital therapies?; A matched study on fracture rates following knee replacement surgeries;


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.