We chose unstable extra-capsular hip fractures as our study group
because these types of fractures suffer the largest blood loss.
We hypothesised that tranexamic acid (TXA) would reduce total blood
loss (TBL) in extra-capsular fractures of the hip. A single-centre placebo-controlled double-blinded randomised
clinical trial was performed to test the hypothesis on patients
undergoing surgery for extra-capsular hip fractures. For reasons
outside the control of the investigators, the trial was stopped
before reaching the 120 included patients as planned in the protocol. Aims
Patients and Methods
Until now, there has been no consensus as to whether stemmed
acetabular components are appropriate for use in patients undergoing
revision total hip arthroplasty (THA) who have major acetabular
defects or pelvic discontinuity. We wished to address this deficiency
in the literature. We carried out a retrospective study of 35 patients (six men
and 29 women) with a mean age of 68 years (37 to 87), with major
acetabular defects who underwent revision THA between 2000 and 2012.Aim
Patients and Methods
The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.Objectives
Methods
Charcot neuro-osteoarthropathy (CN) of the midfoot
presents a major reconstructive challenge for the foot and ankle
surgeon. The Synthes 6 mm Midfoot Fusion Bolt is both designed and
recommended for patients who have a deformity of the medial column
of the foot due to CN. We present the results from the first nine
patients (ten feet) on which we attempted to perform fusion of the
medial column using this bolt. Six feet had concurrent hindfoot fusion
using a retrograde nail. Satisfactory correction of deformity of
the medial column was achieved in all patients. The mean correction
of calcaneal pitch was from 6°
(-15° to +18°) pre-operatively to 16° (7° to 23°) post-operatively;
the mean Meary angle from 26° (3° to 46°) to 1° (1° to 2°); and
the mean talometatarsal angle on dorsoplantar radiographs from 27°
(1° to 48°) to 1° (1° to 3°). However, in all but two feet, at least one joint failed to fuse.
The bolt migrated in six feet, all of which showed progressive radiographic
osteolysis, which was considered to indicate loosening. Four of
these feet have undergone a revision procedure, with good radiological
evidence of fusion. The medial column bolt provided satisfactory correction
of the deformity but failed to provide adequate fixation for fusion
in CN deformities in the foot. In its present form, we cannot recommend the routine use of this
bolt. Cite this article:
The aim of this study was to examine the results of revision
total knee arthroplasty (TKA) undertaken for stiffness in the absence
of sepsis or loosening. We present the results of revision surgery for stiff TKA in 48
cases (35 (72.9%) women and 13 (27.1%) men). The mean age at revision
surgery was 65.5 years (42 to 83). All surgeries were performed
by a single surgeon. Stiffness was defined as an arc of flexion
of <
70° or a flexion contracture of >
15°. The changes in the
range of movement (ROM) and the Western Ontario and McMasters Osteoarthritis
index scores (WOMAC) were recorded.Aims
Patients and Methods
Controversy remains whether the contralateral
hip should be fixed in patients presenting with unilateral slipped capital
femoral epiphysis (SCFE). This retrospective study compares the
outcomes and cost of those patients who had prophylactic fixation
with those who did not. Between January 2000 and December 2010 a total of 50 patients
underwent unilateral fixation and 36 had prophylactic fixation of
the contralateral hip. There were 54 males and 32 females with a
mean age of 12.3 years (9 to 16). The rate of a subsequent slip
without prophylactic fixation was 46%. The risk of complications
was greater, the generic health measures (Short Form-12 physical
(p <
0.001) and mental (p = 0.004) summary scores) were worse.
Radiographic cam lesions in patients presenting with unilateral
SCFE were only seen in patients who did not have prophylactic fixation.
Furthermore, prophylactic fixation of the contralateral hip was
found to be a cost-effective procedure, with a cost per quality
adjusted life year gained of £1431 at the time of last follow-up. Prophylactic fixation of the contralateral hip is a cost-effective
operation that limits the morbidity from the complications of a
further slip, and the diminished functional outcome associated with
unilateral fixation. Cite this article:
We report our experience of performing an elbow
hemiarthroplasty in the treatment of comminuted distal humeral fractures
in the elderly patients. A cohort of 42 patients (three men and 39 women, mean age 72;
56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after
surgery. Functional outcome was measured with the Mayo Elbow Performance
Score (MEPS) and range of movement. The disabilities of the arm,
shoulder and hand questionnaire (DASH) was used as a patient rated
evaluation. Complications and ulnar nerve function were recorded.
Plain radiographs were obtained to assess prosthetic loosening,
olecranon wear and heterotopic bone formation. The mean extension deficit was 23.5° (0° to 60°) and mean flexion
was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°).
The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0
to 63). Four patients had additional surgery for limited range of
movement and one for partial instability. One elbow was revised
due to loosening, two patients had sensory ulnar nerve symptoms,
and radiographic signs of mild olecranon wear was noted in five
patients. Elbow hemiarthroplasty for comminuted intra-articular distal
humeral fractures produces reliable medium-term results with functional
outcome and complication rates, comparable with open reduction and
internal fixation and total elbow arthroplasty. Cite this article:
We present detailed information about early morbidity
after aseptic revision knee replacement from a nationwide study.
All aseptic revision knee replacements undertaken between 1st October
2009 and 30th September 2011 were analysed using the Danish National
Patient Registry with additional information from the Danish Knee
Arthroplasty Registry. The 1218 revisions involving 1165 patients
were subdivided into total revisions, large partial revisions, partial
revisions and revisions of unicondylar replacements (UKR revisions).
The mean age was 65.0 years (27 to 94) and the median length of
hospital stay was four days (interquartile range: 3 to 5), with
a 90 days re-admission rate of 9.9%,
re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges
of 51 to 55 years (p = 0.018), 76 to 80 years (p <
0.001) and ≥ 81
years (p <
0.001) were related to an increased risk of re-admission.
The age ranges of 76 to 80 years (p = 0.018) and the large partial
revision subgroup (p = 0.073) were related to an increased risk
of re-operation. The ages from 76 to 80 years (p <
0.001), age ≥ 81
years (p <
0.001) and surgical time >
120 min (p <
0.001)
were related to increased length of hospital stay, whereas the use
of a tourniquet (p = 0.008) and surgery in a low volume centre (p
= 0.013) were related to shorter length of stay. In conclusion, we found a similar incidence of early post-operative
morbidity after aseptic knee revisions as has been reported after
primary procedures. This suggests that a length of hospital stay ≤ four
days and discharge home at that time is safe following aseptic knee
revision surgery in Denmark. Cite this article:
The August 2014 Knee Roundup360 looks at: re-admission following total knee replacement; out with the old and in with the new? computer navigation revisited; approach less important in knee replacement; is obesity driving a rise in knee replacements?; knee replacement isn’t cheap in the obese; cruciate substitution doesn’t increase knee flexion; and sonication useful diagnostic aid in two-stage revision.
Induced membrane technique is a relatively new technique in the reconstruction of large bone defects. It involves the implantation of polymethylmethacrylate (PMMA) cement in the bone defects to induce the formation of membranes after radical debridement and reconstruction of bone defects using an autologous cancellous bone graft in a span of four to eight weeks. The purpose of this study was to explore the clinical outcomes of the induced membrane technique for the treatment of post-traumatic osteomyelitis in 32 patients. A total of 32 cases of post-traumatic osteomyelitis were admitted to our department between August 2011 and October 2012. This retrospective study included 22 men and ten women, with a mean age of 40 years (19 to 70). Within this group there were 20 tibias and 12 femurs with a mean defect of 5 cm (1.5 to 12.5). Antibiotic-loaded PMMA cement was inserted into the defects after radical debridement. After approximately eight weeks, the defects were implanted with bone graft.Objectives
Methods
To prevent insufficiency of the triceps after
total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar
approach. This study evaluates the clinical results and post-operative
alignment of the prosthesis using this approach. We reviewed 25 elbows in 23 patients. There were five men and
18 women with a mean age of 69 years (54 to 83). There were 18 elbows
with rheumatoid arthritis, six with a fracture or pseudoarthrosis
and one elbow with osteoarthritis. Post-operative complications included one intra-operative fracture,
one elbow with heterotopic ossification, one transient ulnar nerve
palsy, and one elbow with skin necrosis, but no elbow was affected
by insufficiency of the triceps. Patients were followed for a mean of 42 months (24 to 77). The
mean post-operative Japanese Orthopaedic Association Elbow Score
was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8
(65 to 100). The mean post-operative flexion/extension of the elbow
was 135°/-8°. The Manual Muscle Testing score of the triceps was
5 in 23 elbows and 2 in two elbows (one patient). The mean alignment
of the implants examined by 3D-CT was 2.8° pronation (standard deviation
( The triceps-sparing ulnar approach allows satisfactory alignment
of the implants, is effective in preventing post-operative triceps
insufficiency, and gives satisfactory short-term results. Cite this article: 2015;97-B:1096–1101.
The purpose of this study was to refine an accepted contaminated
rat femur defect model to result in an infection rate of approximately
50%. This threshold will allow examination of treatments aimed at
reducing infection in open fractures with less risk of type II error. Defects were created in the stablised femurs of anaethetised
rats, contaminated with Objectives
Methods
A retrospective review was performed of patients
undergoing primary cementless total knee replacement (TKR) using
porous tantalum performed by a group of surgical trainees. Clinical
and radiological follow-up involved 79 females and 26 males encompassing
115 knees. The mean age was 66.9 years (36 to 85). Mean follow-up
was 7 years (2 to 11). Tibial and patellar components were porous
tantalum monoblock implants, and femoral components were posterior
stabilised (PS) in design with cobalt–chromium fibre mesh. Radiological
assessments were made for implant positioning, alignment, radiolucencies,
lysis, and loosening. There was 95.7% survival of implants. There
was no radiological evidence of loosening and no osteolysis found.
No revisions were performed for aseptic loosening. Average tibial
component alignment was 1.4° of varus (4°of valgus to 9° varus),
and 6.2° (3° anterior to 15° posterior) of posterior slope. Mean
femoral component alignment was 6.6° (1° to 11°) of valgus. Mean tibiofemoral
alignment was 5.6° of valgus (7° varus to 16° valgus). Patellar
tilt was a mean of 2.4° lateral (5° medial to 28° lateral). Patient
satisfaction with improvement in pain was 91%. Cementless TKR incorporating
porous tantalum yielded good clinical and radiological outcomes
at a mean of follow-up of seven-years. Cite this article:
The aim of this study was to compare the operating
time, length of stay (LOS), adverse events and rate of re-admission
for elderly patients with a fracture of the hip treated using either
general or spinal anaesthesia. Patients aged ≥ 70 years who underwent
surgery for a fracture of the hip between 2010 and 2012 were identified
from the American College of Surgeons National Surgical Quality
Improvement Program (ACS-NSQIP) database. Of the 9842 patients who
met the inclusion criteria, 7253 (73.7%) were treated with general
anaesthesia and 2589 (26.3%) with spinal anaesthesia. On propensity-adjusted
multivariate analysis, general anaesthesia was associated with slightly increased
operating time (+5 minutes, 95% confidence interval (CI) +4 to +6,
p <
0.001) and post-operative time in the operating room (+5
minutes, 95% CI +2 to +8, p <
0.001) compared with spinal anaesthesia.
General anaesthesia was associated with a shorter LOS (hazard ratio
(HR) 1.28, 95% CI 1.22 to 1.34, p <
0.001). Any adverse event
(odds ratio (OR) 1.21, 95% CI 1.10 to 1.32, p <
0.001), thromboembolic
events (OR 1.90, 95% CI 1.24 to 2.89, p = 0.003), any minor adverse
event (OR 1.19, 95% CI 1.09 to 1.32, p <
0.001), and blood transfusion
(OR 1.34, 95% CI 1.22 to 1.49, p <
0.001) were associated with
general anaesthesia. General anaesthesia was associated with decreased
rates of urinary tract infection (OR 0.73, 95% CI 0.62 to 0.87,
p <
0.001). There was no clear overall advantage of one type
of anaesthesia over the other, and surgeons should be aware of the
specific risks and benefits associated with each type. Cite this article: