We determined serum cobalt levels in 55 patients by atomic absorption spectrophotometry before and after implantation of uncemented total hip arthroplasties. In a randomised,
In a
Osteotomy has been used in the treatment of unstable intertrochanteric hip fractures in an attempt to increase the stability of the fracture fragments. We have assessed this stability in a randomised
We report a
Aims. Displaced fractures of the lateral condyle of the humerus are
frequently managed surgically with the aim of avoiding nonunion,
malunion, disturbances of growth and later arthritis. The ideal
method of fixation is however not known, and treatment varies between
surgeons and hospitals. The aim of this study was to compare the
outcome of two well-established forms of surgical treatment, Kirschner
wire (K-wire) and screw fixation. Patients and Methods. A retrospective cohort study of children who underwent surgical
treatment for a fracture of the lateral condyle of the humerus between
January 2005 and December 2014 at two centres was undertaken. Pre,
intraoperative and postoperative characteristics were evaluated. A total of 336 children were included in the study. Their mean
age at the time of injury was 5.8 years (0 to 15) with a male:female
patient ratio of 3:2. A total of 243 (72%) had a Milch II fracture
and the fracture was displaced by > 2 mm in 228 (68%). In all, 235
patients underwent K-wire fixation and 101 had screw fixation. . Results. There was a higher rate of nonunion with K-wire fixation (p =
0.02). There was no difference in Baumann’s angle, carrying angle
or the rate of major complications between the two groups. No benefit
was obtained by immobilizing the elbow for more than four weeks
in either group. No short-term complications were seen when fixation
crossed the lateral ossific nucleus. Conclusions. Fixation of lateral condylar humeral fractures in children using
either K-wires or screws gives satisfactory results. Proponents
of both techniques may find justification of their methods in our
data, but
We have examined the effect of arthrodiastasis on the preservation of the femoral head in older children with Perthes’ disease. We carried out a
In a
A new and simple operative technique has been developed to provide rigid internal fixation for all types of fractures of the scaphoid. This involves the use of a double-threaded bone screw which provides such good fixation that, after operation, a plaster cast is rarely required and most patients are able to return to work within a few weeks. A classification of scaphoid fractures is proposed. The indications for operation included not only acute unstable fractures, but also fractures with delayed healing and those with established non-union; screw fixation was combined with bone grafting to treat non-union. In a
Previous studies of the Ilizarov procedure have concentrated on musculoskeletal assessments rather than the opinions of patients. In a
We performed a randomised
We report a randomised
We present the results of a
We performed a randomised,
Total hip and total knee arthroplasty both provide a considerable improvement in quality of life, but there is no evidence to suggest that one is more successful than the other. We studied 72 patients in a
Neither a surgeon’s intraoperative impression nor the parameters of computer navigation have been shown to be predictive of the outcomes following total knee arthroplasty (TKA). The aim of this study was to determine whether a surgeon, with robotic assistance, can predict the outcome as assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) for pain (KPS), one year postoperatively, and establish what factors correlate with poor KOOS scores in a well-aligned and balanced TKA. A total of 134 consecutive patients who underwent TKA using a dynamic ligament tensioning robotic system with a tibia first resection technique and a cruciate sacrificing ultracongruent TKA system were enrolled into a prospective study. Each TKA was graded based on the final mediolateral ligament balance at 10° and 90° of flexion: 1) < 1 mm difference in the thickness of the tibial insert and that which was planned (n = 75); 2) < 1 mm difference (n = 26); 3) between 1 mm to 2 mm difference (n = 26); and 4) > 2 mm difference (n = 7). The mean one-year KPS score for each grade of TKA was compared and the likelihood of achieving an KPS score of > 90 was calculated. Finally, the factors associated with lower KPS despite achieving a high-grade TKA (grade A and B) were analyzed.Aims
Methods
We have studied prospectively the outcome of wound discharge in patients after arthroplasty of the hip and knee. Over a period of 3.5 years 530 primary arthroplasties were carried out in one hospital. Postoperative wound infections developed in 82. At a mean follow-up of two years a comparison was made between these patients and 82 with healthy wounds, in terms of symptoms and signs of deep infection. There was an incidence of 1.1% of early deep infection, within six weeks in all cases. The rate of ‘superficial’ infection was 17.3% in the hips, 10.5% in the knees and 14.3% in total. At a mean follow-up of 26 months, there were no significant differences between the patients with infected wounds and a matched group of patients with healthy wounds in terms of the ESR, level of C-reactive protein, white cell count and radiological scores, but clinical scores were significantly worse in the patients with infected knees (p <
0.05). The length of stay was also significantly longer in this group (mean 14.6 days in the healthy wound group, 19 days in the problem group; p <
0.005). There was, however, no convincing evidence that these wound infections led to deep infection and early revision in the early to medium follow-up period. A larger and longer
Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and anatomical loading. A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. This single cohort was then retrospectively compared with previously reported randomized cohorts of cemented monoblock (cemented) and trabecular metal (trabecular) acetabular implants. The primary outcome measure was periprosthetic bone density using dual-energy x-ray absorptiometry over two years. Secondary outcomes included radiological and clinical analysis.Aims
Methods