The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 943 - 947
1 Jul 2007
Wong KC Kumta SM Chiu KH Antonio GE Unwin P Leung KS

The use of a navigation system in musculoskeletal tumour surgery enables the integration of pre-operative CT and MRI images to generate a precise three-dimensional anatomical model of the site and the extent of the tumour.

We carried out six consecutive resections of musculoskeletal tumour in five patients using an existing commercial computer navigation system. There were three women and two men with a mean age of 41 years (24 to 47). Reconstruction was performed using a tumour prosthesis in three lesions and a vascularised fibular graft in one. No reconstruction was needed in two cases. The mean follow-up was 6.9 months (3.5 to 10). The mean duration of surgery was 28 minutes (13 to 50). Examination of the resected specimens showed clear margins in all the tumour lesions and a resection that was exactly as planned.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1244 - 1249
1 Sep 2013
Jeon C Park J Chung N Son K Lee Y Kim J

We investigated the spinopelvic morphology and global sagittal balance of patients with a degenerative retrolisthesis or anterolisthesis. A total of 269 consecutive patients with a degenerative spondylolisthesis were included in this study. There were 95 men and 174 women with a mean age of 64.3 years (sd 10.5; 40 to 88). A total of 106 patients had a pure retrolisthesis (R group), 130 had a pure anterolisthesis (A group), and 33 had both (R+A group).

A backward slip was found in the upper lumbar levels (mostly L2 or L3) with an almost equal gender distribution in both the R and R+A groups. The pelvic incidence and sacral slope of the R group were significantly lower than those of the A (both p < 0.001) and R+A groups (both p < 0.001). The lumbar lordosis of the R+A group was significantly greater than that of the R (p = 0.025) and A groups (p = 0.014). The C7 plumb line of the R group was located more posteriorly than that of the A group (p = 0.023), but was no different from than that of the R+A group (p = 0.422). The location of C7 plumb line did not differ between the three groups (p = 0.068). The spinosacral angle of the R group was significantly smaller than that of the A group (p < 0.001) and R+A group (p < 0.001).

Our findings imply that there are two types of degenerative retrolisthesis: one occurs primarily as a result of degeneration in patients with low pelvic incidence, and the other occurs secondarily as a compensatory mechanism in patients with an anterolisthesis and high pelvic incidence.

Cite this article: Bone Joint J 2013;95-B:1244–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 455 - 460
1 Apr 2007
Sugano N Nishii T Miki H Yoshikawa H Sato Y Tamura S

We have developed a CT-based navigation system using infrared light-emitting diode markers and an optical camera. We used this system to perform cementless total hip replacement using a ceramic-on-ceramic bearing couple in 53 patients (60 hips) between 1998 and 2001. We reviewed 52 patients (59 hips) at a mean of six years (5 to 8) postoperatively. The mid-term results of total hip replacement using navigation were compared with those of 91 patients (111 hips) who underwent this procedure using the same implants, during the same period, without navigation. There were no significant differences in age, gender, diagnosis, height, weight, body mass index, or pre-operative clinical score between the two groups. The operation time was significantly longer where navigation was used, but there was no significant difference in blood loss or navigation-related complications. With navigation, the acetabular components were placed within the safe zone defined by Lewinnek, while without, 31 of the 111 components were placed outside this zone. There was no significant difference in the Merle d’Aubigne and Postel hip score at the final follow-up. However, hips treated without navigation had a higher rate of dislocation. Revision was performed in two cases undertaken without navigation, one for aseptic acetabular loosening and one for fracture of a ceramic liner, both of which showed evidence of neck impingement on the liner. A further five cases undertaken without navigation showed erosion of the posterior aspect of the neck of the femoral component on the lateral radiographs. These seven impingement-related mechanical problems correlated with malorientation of the acetabular component. There were no such mechanical problems in the navigated group.

We conclude that CT-based navigation increased the precision of orientation of the acetabular component and control of limb length in total hip replacement, without navigation-related complications. It also reduced the rate of dislocation and mechanical problems related to impingement.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 851 - 854
1 Jun 2013
Madhuri V Arora SK Dutt V

Slipped capital femoral epiphysis (SCFE) is uncommon in India and we routinely look for associated metabolic or endocrine abnormalities. In this study we investigated a possible association between vitamin D deficiency and SCFE. All children presenting with SCFE during the study period had their 25-hydroxyvitamin D levels measured as part of an overall metabolic, renal and endocrine status evaluation, which included measurement of body mass index (BMI). Vitamin D status was compared with age-, gender- and habitat-matched controls with acute trauma or sepsis presenting to our emergency department.

A total of 15 children (12 boys and three girls) with a mean age of 13 years (sd 1.81; 10 to 16) presented for treatment for SCFE during a two-year period beginning in January 2010. Renal and thyroid function was within the normal range in all cases. The mean BMI was 24.9 kg/m2 (17.0 to 33.8), which was significantly higher than that of the controls (p = 0.006). There was a statistically significant difference between the mean values of 25-hydroxyvitamin D in the children with SCFE and the controls (11.78 ng/ml (sd 5.4) versus 27.06 ng/ml (sd 5.53), respectively; p < 0.001). We concluded that, along with high BMI, there is a significant association of vitamin D deficiency and SCFE in India.

Cite this article: Bone Joint J 2013;95-B:851–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 548 - 555
1 Apr 2005
Dobson F Graham HK Baker R Morris ME

Most children with spastic hemiplegia have high levels of function and independence but fixed deformities and gait abnormalities are common. The classification proposed by Winters et al is widely used to interpret hemiplegic gait patterns and plan intervention. However, this classification is based on sagittal kinematics and fails to consider important abnormalities in the transverse plane. Using three-dimensional gait analysis, we studied the incidence of transverse-plane deformity and gait abnormality in 17 children with group IV hemiplegia according to Winters et al before and after multilevel orthopaedic surgery.

We found that internal rotation of the hip and pelvic retraction were consistent abnormalities of gait in group-IV hemiplegia. A programme of multilevel surgery resulted in predictable improvement in gait and posture, including pelvic retraction. In group IV hemiplegia pelvic retraction appeared in part to be a compensating mechanism to control foot progression in the presence of medial femoral torsion. Correction of this torsion can improve gait symmetry and function.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1602 - 1609
1 Dec 2011
Malviya A Ramaskandhan JR Bowman R Hashmi M Holland JP Kometa S Lingard E

The aim of this study was to investigate the possible benefit of large-head metal-on-metal bearing on a stem for primary hip replacement compared with a 28 mm diameter conventional metal-on-polyethylene bearing in a prospective randomised controlled trial. We investigated cemented stem behaviour between these two different bearings using Einzel-Bild-Röntgen-Analyse, clinical and patient reported measures (Harris hip score, Western Ontario and McMaster Universities osteoarthritis index, Short Form-36 and satisfaction) and whole blood metal ion levels at two years. A power study indicated that 50 hips were needed in each group to detect subsidence of > 5 mm at two years with a p-value of < 0.05.

Significant improvement (p < 0.001) was found in the mean clinical and patient reported outcomes at two years for both groups. Comparison of outcomes between the groups at two years showed no statistically significant difference for mean stem migration, clinical and patient reported outcomes; except overall patient satisfaction which was higher for metal-on-metal group (p = 0.05). Metal ion levels were raised above the Medicines and Healthcare products Regulatory Agency advised safety level (7 µg per litre) in 20% of the metal-on-metal group and in one patient in metal-on-polyethylene group (who had a metal-on-metal implant on the contralateral side). Two patients in the metal-on-metal group were revised, one for pseudotumour and one for peri-prosthetic fracture.

Use of large modular heads is associated with a risk of raised whole blood metal ion levels despite using a proven bearing from resurfacing. The head-neck junction or excess stem micromotion are possibly the weak links warranting further research.


Bone & Joint Research
Vol. 2, Issue 8 | Pages 149 - 154
1 Aug 2013
Aurégan J Coyle RM Danoff JR Burky RE Akelina Y Rosenwasser MP

Objectives

One commonly used rat fracture model for bone and mineral research is a closed mid-shaft femur fracture as described by Bonnarens in 1984. Initially, this model was believed to create very reproducible fractures. However, there have been frequent reports of comminution and varying rates of complication. Given the importance of precise anticipation of those characteristics in laboratory research, we aimed to precisely estimate the rate of comminution, its importance and its effect on the amount of soft callus created. Furthermore, we aimed to precisely report the rate of complications such as death and infection.

Methods

We tested a rat model of femoral fracture on 84 rats based on Bonnarens’ original description. We used a proximal approach with trochanterotomy to insert the pin, a drop tower to create the fracture and a high-resolution fluoroscopic imager to detect the comminution. We weighed the soft callus on day seven and compared the soft callus parameters with the comminution status.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1308 - 1316
1 Oct 2013
Stokes OM Luk KDK

Adolescent idiopathic scoliosis affects about 3% of children. Non-operative measures are aimed at altering the natural history to maintain the size of the curve below 40° at skeletal maturity. The application of braces to treat spinal deformity pre-dates the era of evidence-based medicine, and there is a paucity of irrefutable prospective evidence in the literature to support their use and their effectiveness has been questioned.

This review considers this evidence. The weight of the evidence is in favour of bracing over observation. The most recent literature has moved away from addressing this question, and instead focuses on developments in the design of braces and ways to improve compliance.

Cite this article: Bone Joint J 2013;95-B:1308–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1079 - 1084
1 Aug 2010
Muirhead-Allwood S Sandiford N Skinner JA Hua J Kabir C Walker PS

We present the 10- to 17-year results of 112 computer-assisted design computer-assisted manufacture femoral components. The total hip replacements were performed between 1992 and 1998 in 111 patients, comprising 53 men and 58 women. Their mean age was 46.2 years (24.6 to 62.2) with a mean follow-up of 13 years (10 to 17). The mean Harris Hip Score improved from 42.4 (7 to 99) to 90.3 (38 to 100), the mean Oxford Hip Score from 43.1 (12 to 59) to 18.2 (12 to 51) and the mean Western Ontario MacMasters University Osteoarthritis Index score from 57.0 (7 to 96) to 11.9 (0 to 85). There was one revision due to failure of the acetabular component but no failures of the femoral component. There were no revisions for aseptic loosening. The worst-case survival in this cohort of custom femoral components at 13.2 years follow-up was 98.2% (95% confidence interval 95 to 99). Overall survival of this series of total hip replacements was 97.3% (95% confidence interval 95 to 99).

These results are comparable with the best medium- to long-term results for femoral components used in primary total hip replacement with any means of fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 273 - 273
1 Feb 2011
Kolar MK Joseph S McLaren A

We present the case of a young male patient with inferior dislocation of the hip and postulate a possible mechanism for this extremely rare injury.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 764 - 769
1 Jun 2013
Roche JJW Jones CDS Khan RJK Yates PJ

The piriformis muscle is an important landmark in the surgical anatomy of the hip, particularly the posterior approach for total hip replacement (THR). Standard orthopaedic teaching dictates that the tendon must be cut in to allow adequate access to the superior part of the acetabulum and the femoral medullary canal. However, in our experience a routine THR can be performed through a posterior approach without sacrificing this tendon.

We dissected the proximal femora of 15 cadavers in order to clarify the morphological anatomy of the piriformis tendon. We confirmed that the tendon attaches on the crest of the greater trochanter, in a position superior to the trochanteric fossa, away from the entry point for broaching the intramedullary canal during THR. The tendon attachment site encompassed the summit and medial aspect of the greater trochanter as well as a variable attachment to the fibrous capsule of the hip joint. In addition we dissected seven cadavers resecting all posterior attachments except the piriformis muscle and tendon in order to study their relations to the hip joint, as the joint was flexed. At flexion of 90° the piriformis muscle lay directly posterior to the hip joint.

The piriform fossa is a term used by orthopaedic surgeons to refer the trochanteric fossa and normally has no relation to the attachment site of the piriformis tendon. In hip flexion the piriformis lies directly behind the hip joint and might reasonably be considered to contribute to the stability of the joint.

We conclude that the anatomy of the piriformis muscle is often inaccurately described in the current surgical literature and terms are used and interchanged inappropriately.

Cite this article: Bone Joint J 2013;95-B:764–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 980 - 983
1 Jul 2011
Malhas AM Grimer RJ Abudu A Carter SR Tillman RM Jeys L

We investigated the eventual diagnosis in patients referred to a tertiary centre with a possible diagnosis of a primary bone malignancy.

We reviewed our database from between 1986 and 2010, during which time 5922 patients referred with a suspicious bone lesion had a confirmed diagnosis. This included bone sarcoma in 2205 patients (37%), benign bone tumour in 1309 (22%), orthopaedic conditions in 992 (17%), metastatic disease in 533 (9%), infection in 289 (5%) and haematological disease in 303 (5%). There was a similar frequency of all diagnoses at different ages except for metastatic disease. Only 0.6% of patients (17 of 2913) under the age of 35 years had metastatic disease compared with 17.1% (516 of 3009) of those over 35 years (p < 0.0001). Of the 17 patients under 35 years with metastatic disease, only four presented with an isolated lesion, had no past history of cancer and were systematically well.

Patients under the age of 35 years should have suitable focal imaging (plain radiography, CT or MRI) and simple systemic studies (blood tests and chest radiography). Reduction of the time to biopsy can be achieved by avoiding an unnecessary investigation for a primary tumour to rule out metastatic disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 427 - 433
1 Apr 2006
van Vugt AB van Kampen A


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1194 - 1200
1 Sep 2011
Akiyama H Yamamoto K Tsukanaka M Kawanabe K Otsuka H So K Goto K Nakamura T

We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts were used for the management of Type III defects in 23 hips. A total of five hips showed radiological failure at a mean follow-up of 6.7 years (4.5 to 9.3), two of which were infected. The mean pre-operative Merle d’Aubigné score was 10 (5 to 15) vs 13.6 (9 to 18) at the latest follow-up. The Kaplan-Meier survival rate at ten years, calculated using radiological failure or revision of the acetabular component for any reason as the endpoint, was 87% (95% confidence interval 76.3 to 97.7). A separate experimental analysis of the mechanical properties of the device and the load-displacement properties of bone grafts showed that a structurally hard allograft resected from femoral heads of patients with osteoarthritis should be preferentially used in any type of defect. If impacted bone allografts were used, a bone graft thickness of < 25 mm was acceptable in Type II defects.

This clinical study indicates that revision total hip replacement using the Kerboull-type acetabular reinforcement device with bone allografts yielded satisfactory mid-term results.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1088 - 1093
1 Aug 2013
Hsu W Lai L Chang H Hsu RW

It has been suggested that extracorporeal shockwave therapy is a safe and effective treatment for pain relief from recalcitrant plantar fasciopathy (PF). However, the changes in gait and associated biomechanical parameters have not been well characterised. We recruited 12 female patients with recalcitrant PF who had a mean age of 59 years (50 to 70) and mean body mass index of 25 kg/m2 (22 to 30). The patients reported a mean duration of symptoms of 9.3 months (6 to 15). Shockwave therapy consisting of 1500 impulses (energy flux density 0.26 mJ/mm2) was applied for three sessions, each three weeks apart. A pain visual analogue scale (VAS) rating, plantar pressure assessment and motion analysis were carried out before and nine weeks after first shock wave therapy. It was demonstrated that patients increased their walking velocity and cadence as well indicating a decrease in pain after shockwave therapy. In the symptomatic foot, the peak contact pressure over the forefoot increased and the contact area over the digits decreased. The total foot impulse also decreased as did stance duration. The duration the centre of pressure remained in the hindfoot increased in the symptomatic foot after shockwave therapy. The differences in centre of pressure trajectory at baseline decreased at final follow-up. In conclusion, shockwave therapy not only decreased the pain VAS rating but also improved the gait parameters of the symptomatic foot in PF patients.

Cite this article: Bone Joint J 2013;95-B:1088–93.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 578 - 582
1 May 2013
Kim S Postigo R Koo S Kim JH

The timing of total hip replacement (THR) in patients with active tuberculosis (TB) of the hip is controversial, because of the potential risk of reactivation of infection. There is little information about the outcome of THR in these patients. We conducted a systematic review of published studies that evaluated the outcome of THR in patients with active TB of the hip. A review of multiple databases referenced articles published between 1950 and 2012. A total of six articles were identified, comprising 65 patients. TB was confirmed histologically in all patients. The mean follow-up was 53.2 months (24 to 108). Antituberculosis treatment continued post-operatively for between six and 15 months, after debridement and THR. One non-compliant patient had reactivation of infection. At the final follow-up the mean Harris hip score was 91.7 (56 to 98). We conclude that THR in patients with active TB of the hip is a safe procedure, providing symptomatic relief and functional improvement if undertaken in association with extensive debridement and appropriate antituberculosis treatment.

Cite this article: Bone Joint J 2013;95-B:578–82.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1464 - 1473
1 Nov 2013
Vendittoli P Rivière C Roy AG Barry J Lusignan D Lavigne M

A total of 219 hips in 192 patients aged between 18 and 65 years were randomised to 28-mm metal-on-metal uncemented total hip replacements (THRs, 107 hips) or hybrid hip resurfacing (HR, 112 hips). At a mean follow-up of eight years (6.6 to 9.3) there was no significant difference between the THR and HR groups regarding rate of revision (4.0% (4 of 99) vs 5.8% (6 of 104), p = 0.569) or re-operation rates without revision (5.1% (5 of 99) vs 2.9% (3 of 104), p = 0.428). In the THR group one recurrent dislocation, two late deep infections and one peri-prosthetic fracture required revision, whereas in the HR group five patients underwent revision for femoral head loosening and one for adverse reaction to metal debris. The mean University of California, Los Angeles activity scores were significantly higher in HR (7.5 (sd 1.7) vs 6.9 (sd 1.7), p = 0.035), but similar mean Western Ontario and McMaster Universities Osteoarthritis Index scores were obtained (5.8 (sd 9.5) in HR vs 5.1 (sd 8.9) in THR, p = 0.615) at the last follow-up. Osteolysis was found in 30 of 81 THR patients (37.4%), mostly in the proximal femur, compared with two of 83 HR patients (2.4%) (p < 0.001). At five years the mean metal ion levels were < 2.5 μg/l for cobalt and chromium in both groups; only titanium was significantly higher in the HR group (p = 0.001). Although revision rates and functional scores were similar in both groups at mid-term, long-term survival analysis is necessary to determine whether one procedure is more advantageous than the other.

Cite this article: Bone Joint J 2013;95-B:1464–73.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 510 - 511
1 Apr 2008
Wong K Ng TP Chiu KY

Arthrodesis of the hip has been employed since the late 19th century. Late complications can arise decades after fusion in patients who were previously asymptomatic. We describe two patients who developed pain in the hip many years after a successful fusion. There was no infection or loosening of the implants. After careful investigation, including oblique radiographs and diagnostic injections of local anaesthetic, the pain was found to be caused by protrusion of the implant. Subsequent removal of the device resulted in complete resolution of the symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 390 - 392
1 Mar 2007
Manzotti A Confalonieri N Pullen C

We report the case of a 74-year-old woman who sustained an intertrochanteric fracture of the femoral neck in a previously arthrodesed hip. The hip arthrodesis had been performed 53 years earlier to treat septic arthritis. The fracture was treated successfully using a double-plating technique with 4.5 mm titanium reconstruction plates.