We investigated the incidence of and risk factors
for venous thromboembolism (VTE) following surgery of the shoulder
and elbow and assessed the role of thromboprophylaxis in upper limb
surgery. All papers describing VTE after shoulder and elbow surgery
published in the English language literature before 31 March 2012
were reviewed. A total of 14 papers were available for analysis,
most of which were retrospective studies and case series. The incidence
of VTE was 0.038% from 92 440 shoulder arthroscopic procedures,
0.52% from 42 261 shoulder replacements, and 0.64% from 4833 procedures
for fractures of the proximal humerus (open reduction and internal fixation
or hemiarthroplasty). The incidence following replacement of the
elbow was 0.26% from 2701 procedures. Diabetes mellitus, rheumatoid
arthritis and ischaemic heart disease were identified as the major
risk factors. The evidence that exists on thromboprophylaxis is based on level
III and IV studies, and we therefore cannot make any recommendations
on prophylaxis based on the current evidence. It seems reasonable
to adopt a multimodal approach that involves all patients receiving
mechanical prophylaxis, with chemical prophylaxis reserved for those
who are at high risk for VTE. Cite this article:
Recent events have highlighted the importance
of implant design for survival and wear-related complications following
metal-on-metal hip resurfacing arthroplasty. The mid-term survival
of the most widely used implant, the Birmingham Hip Resurfacing
(BHR), has been described by its designers. The aim of this study
was to report the ten-year survival and patient-reported functional
outcome of the BHR from an independent centre. In this cohort of 554 patients (646 BHRs) with a mean age of
51.9 years (16.5 to 81.5) followed for a mean of eight years (1
to 12), the survival and patient-reported functional outcome depended
on gender and the size of the implant. In female hips (n = 267)
the ten-year survival was 74% (95% confidence interval (CI) 83 to
91), the ten-year revision rate for pseudotumour was 7%, the mean
Oxford hip score (OHS) was 43 ( This study supports the ongoing use of resurfacing in young active
men, who are a subgroup of patients who tend to have problems with
conventional THR. In contrast, the results in women have been poor
and we do not recommend metal-on-metal resurfacing in women. Continuous
follow-up is recommended because of the increasing incidence of
pseudotumour with the passage of time.
We compared lower limb coronal alignment measurements
obtained pre- and post-operatively with long-leg radiographs and
computer navigation in patients undergoing primary total knee replacement
(TKR). A series of 185 patients had their pre- and post-implant
radiological and computer-navigation system measurements of coronal alignment
compared using the Bland-Altman method. The study included 81 men
and 104 women with a mean age of 68.5 years (32 to 87) and a mean
body mass index of 31.7 kg/m2 (19 to 49). Pre-implant
Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability
coefficient of 9.0°. The Bland–Altman plot showed a tendency for the
radiological measurement to indicate a higher level of pre-operative
deformity than the corresponding navigation measurement. Post-implant
limits of agreement were -5.0° to 5.4° with a repeatability coefficient
of 5.2°. The tendency for valgus knees to have greater deformity
on the radiograph was still seen, but was weaker for varus knees. The alignment seen or measured intra-operatively during TKR is
not necessarily the same as the deformity seen on a standing long-leg
radiograph either pre- or post-operatively. Further investigation
into the effect of weight-bearing and surgical exposure of the joint
on the mechanical femorotibial angle is required to enable the most appropriate
intra-operative alignment to be selected.
When transferring tissue regenerative strategies
involving skeletal stem cells to human application, consideration needs
to be given to factors that may affect the function of the cells
that are transferred. Local anaesthetics are frequently used during
surgical procedures, either administered directly into the operative
site or infiltrated subcutaneously around the wound. The aim of
this study was to investigate the effects of commonly used local anaesthetics
on the morphology, function and survival of human adult skeletal
stem cells. Cells from three patients who were undergoing elective hip replacement
were harvested and incubated for two hours with 1% lidocaine, 0.5%
levobupivacaine or 0.5% bupivacaine hydrochloride solutions. Viability
was quantified using WST-1 and DNA assays. Viability and morphology
were further characterised using CellTracker Green/Ethidium Homodimer-1
immunocytochemistry and function was assessed by an alkaline phosphatase
assay. An additional group was cultured for a further seven days
to allow potential recovery of the cells after removal of the local
anaesthetic. A statistically significant and dose dependent reduction in cell
viability and number was observed in the cell cultures exposed to
all three local anaesthetics at concentrations of 25% and 50%, and
this was maintained even following culture for a further seven days. This study indicates that certain local anaesthetic agents in
widespread clinical use are deleterious to skeletal progenitor cells
when studied
The outcome of an anatomical shoulder replacement
depends on an intact rotator cuff. In 1981 Grammont designed a novel
large-head reverse shoulder replacement for patients with cuff deficiency.
Such has been the success of this replacement that it has led to
a rapid expansion of the indications. We performed a systematic
review of the literature to evaluate the functional outcome of each
indication for the reverse shoulder replacement. Secondary outcome
measures of range of movement, pain scores and complication rates
are also presented.
We reviewed 31 consecutive patients with Friedreich’s
ataxia and scoliosis. There were 24 males and seven females with
a mean age at presentation of 15.5 years (8.6 to 30.8) and a mean
curve of 51° (13° to 140°). A total of 12 patients had thoracic
curvatures, 11 had thoracolumbar and eight had double thoracic/lumbar.
Two patients had long thoracolumbar collapsing scoliosis with pelvic
obliquity and four had hyperkyphosis. Left-sided thoracic curves in
nine patients (45%) and increased thoracic kyphosis differentiated
these deformities from adolescent idiopathic scoliosis. There were
17 patients who underwent a posterior instrumented spinal fusion
at mean age of 13.35 years, which achieved and maintained good correction
of the deformity. Post-operative complications included one death due
to cardiorespiratory failure, one revision to address nonunion and
four patients with proximal junctional kyphosis who did not need
extension of the fusion. There were no neurological complications
and no wound infections. The rate of progression of the scoliosis
in children kept under simple observation and those treated with bracing
was less for lumbar curves during bracing and similar for thoracic
curves. The scoliosis progressed in seven of nine children initially
treated with a brace who later required surgery. Two patients presented
after skeletal maturity with balanced curves not requiring correction.
Three patients with severe deformities who would benefit from corrective
surgery had significant cardiac co-morbidities.
Richard Carey Smith is an orthopaedic oncology surgeon with fellowship training in the UK, USA, Australia and Canada, and has worked in Zambia, Zimbabwe and Papa New Guinea. David Wood is head of the University Department of Orthopaedics in Perth, Western Australia. He did his masters in Africa, and first experienced Papa New Guinea on his medical elective, starting a lifelong commitment to medical aid work there.
This study aims to assess the correlation of CT-based structural
rigidity analysis with mechanically determined axial rigidity in
normal and metabolically diseased rat bone. A total of 30 rats were divided equally into normal, ovariectomized,
and partially nephrectomized groups. Cortical and trabecular bone
segments from each animal underwent micro-CT to assess their average
and minimum axial rigidities using structural rigidity analysis.
Following imaging, all specimens were subjected to uniaxial compression
and assessment of mechanically-derived axial rigidity.Objectives
Methods
We report the use of a 15° face-changing cementless
acetabular component in patients undergoing total hip replacement
for osteoarthritis secondary to developmental dysplasia of the hip.
The rationale behind its design and the surgical technique used
for its implantation are described. It is distinctly different from
a standard cementless hemispherical component as it is designed
to position the bearing surface at the optimal angle of inclination,
that is, <
45°, while maximising the cover of the component by
host bone.
We studied the prevalence of severe crouch gait
over a 15-year period in a defined population of children with spastic
diplegia and Gross Motor Function Classification System levels II
and III, to determine if there had been a decrease following changes
to the management of equinus gait. These changes were replacing
observational with three-dimensional gait analysis, replacing single
level with multilevel surgery, and replacing gastrocsoleus lengthening
with gastrocnemius recession. Of 464 children and adolescents with
spastic diplegia who underwent three-dimensional gait analysis,
27 had severe crouch gait. Seventeen of these had been managed by
isolated lengthening of the gastrocsoleus. Following changes in
the management of equinus gait, the prevalence of severe crouch
gait decreased from 25% and stabilised at a significantly lower
rate, fluctuating between 0% and 4% annually (p <
0.001). We conclude that severe crouch gait in this population was precipitated
by isolated lengthening of the gastrocsoleus. These findings may
be relevant to other surgical populations, as severe crouch gait
may be a useful way to monitor the quality of the surgical management
of abnormal gait in children with cerebral palsy and spastic diplegia.
Robots have been used in surgery since the late
1980s. Orthopaedic surgery began to incorporate robotic technology
in 1992, with the introduction of ROBODOC, for the planning and
performance of total hip replacement. The use of robotic systems
has subsequently increased, with promising short-term radiological
outcomes when compared with traditional orthopaedic procedures.
Robotic systems can be classified into two categories: autonomous
and haptic (or surgeon-guided). Passive surgery systems, which represent
a third type of technology, have also been adopted recently by orthopaedic
surgeons. While autonomous systems have fallen out of favour, tactile systems
with technological improvements have become widely used. Specifically,
the use of tactile and passive robotic systems in unicompartmental
knee replacement (UKR) has addressed some of the historical mechanisms
of failure of non-robotic UKR. These systems assist with increasing
the accuracy of the alignment of the components and produce more
consistent ligament balance. Short-term improvements in clinical
and radiological outcomes have increased the popularity of robot-assisted
UKR. Robot-assisted orthopaedic surgery has the potential for improving
surgical outcomes. We discuss the different types of robotic systems
available for use in orthopaedics and consider the indication, contraindications
and limitations of these technologies.
Abnormal knee kinematics following reconstruction
of the anterior cruciate ligament may exist despite an apparent resolution
of tibial laxity and functional benefit. We performed upright, weight-bearing
MR scans of both knees in the sagittal plane at different angles
of flexion to determine the kinematics of the knee following unilateral reconstruction
(n = 12). The uninjured knee acted as a control. Scans were performed
pre-operatively and at three and six months post-operatively. Anteroposterior
tibial laxity was determined using an arthrometer and patient function
by validated questionnaires before and after reconstruction. In
all the knees with deficient anterior cruciate ligaments, the tibial
plateau was displaced anteriorly and internally rotated relative
to the femur when compared with the control contralateral knee,
particularly in extension and early flexion (mean lateral compartment displacement:
extension 7.9 mm ( Our results show that despite improvement in laxity and functional
benefit, abnormal knee kinematics remain at six months and actually
deteriorate from three to six months following reconstruction of
the anterior cruciate ligament.
Isolated fractures of the anterior column and anterior wall are a relatively rare subgroup of acetabular fractures. We report our experience of 30 consecutive cases treated over ten years. Open reduction and internal fixation through an ilioinguinal approach was performed for most of these cases (76.7%) and percutaneous techniques were used for the remainder. At a mean follow-up of four years (2 to 6), 26 were available for review. The radiological and functional outcomes were good or excellent in 23 of 30 patients (76.7%) and 22 of 26 patients (84.6%) according to Matta’s radiological criteria and the modified Merlé d’Aubigné score, respectively. Complications of minor to moderate severity were seen in six of the 30 cases (20%) and none of the patients underwent secondary surgery or replacement of the hip.
Bicruciate-stabilised total knee replacement (TKR) aims to restore normal kinematics by replicating the function of both cruciate ligaments. We performed a prospective, randomised controlled trial in which bicruciate- and posterior-stabilised TKRs were implanted in 13 and 15 osteo-arthritic knees, respectively. The mean age of the bicruciate-stabilised group was 63.9 years ( At near full extension during step-up, the bicruciate-stabilised TKR produced a higher mean PTA than the posterior-stabilised TKR, indicating that the bicruciate design at least partially restored the kinematic role of the anterior cruciate ligament. The bicruciate-stabilised TKR largely restored the pre-operative kinematics, whereas the posterior-stabilised TKR resulted in a consistently lower PTA at all activities. The PTA in the pre-operative knees was higher than in the control group during the step-up and at near full knee extension. Overall, both groups generated a more normal PTA than that seen in previous studies in high knee flexion. This suggested that both designs of TKR were more effective at replicating the kinematic role of the posterior cruciate ligament than those used in previous studies.
The Oxford unicompartmental knee replacement gives good results in patients with symptomatic osteoarthritis of the medial compartment. Previous studies have suggested that the presence of radiolucent lines (RLLs) does not reflect a poor outcome in such patients. However, the reliability and validity of this assessment have not been determined. Our aim was to assess the intra- and interobserver reliability and the sensitivity and specificity of the assessment of RLLs around both tibial and femoral components using standard radiographs. Two reviewers assessed the radiographs of 45 patients who had loosening of the tibial or femoral component confirmed at revision surgery and compared them with those of a series of 45 asymptomatic patients matched for age and gender. The results suggested that, using standard radiographs, tibial RLLs were 63.6% sensitive and 94.4% specific and femoral RLLs 63.9% sensitive and 72.7% specific for loosening. Overall intra- and interobserver reliability was highly variable, but zonal analysis showed that lucency at the tip of the femoral peg was significantly associated with loosening of the femoral component. Fluoroscopically guided radiographs may improve the zonal reliability of the assessment of RLLs, but further independent and comparative studies are required. In the meantime, the innocence of the physiological RLLs detected by standard radiographs should be viewed with caution.
The contraindications for unicompartmental knee replacement (UKR) remain controversial. The views of many surgeons are based on Kozinn and Scott’s 1989 publication which stated that patients who weighed more than 82 kg, were younger than 60 years, undertook heavy labour, had exposed bone in the patellofemoral joint or chondrocalcinosis, were not ideal candidates for UKR. Our aim was to determine whether these potential contraindications should apply to patients with a mobile-bearing UKR. In order to do this the outcome of patients with these potential contraindications was compared with that of patients without the contraindications in a prospective series of 1000 UKRs. The outcome was assessed using the Oxford knee score, the American Knee Society score, the Tegner activity score, revision rate and survival. The clinical outcome of patients with each of the potential contraindications was similar to or better than those without each contraindication. Overall, 678 UKRs (68%) were performed in patients who had at least one potential contraindication and only 322 (32%) in patients deemed to be ideal. The survival at ten years was 97.0% (95% confidence interval 93.4 to 100.0) for those with potential contraindications and 93.6% (95% confidence interval 87.2 to 100.0) in the ideal patients. We conclude that the thresholds proposed by Kozinn and Scott using weight, age, activity, the state of the patellofemoral joint and chondrocalcinosis should not be considered to be contraindications for the use of the Oxford UKR.
There has been debate about the role of unicompartmental knee replacement in the presence of radiologically identifiable degenerative changes of the patellofemoral joint. We studied 195 knees in 163 patients in whom an Oxford unicompartmental knee replacement had been performed for medial osteoarthritis between January 2004 and July 2007. The mean age of the patients was 66 years (51 to 93). The degree of degenerative change of the patellofemoral joint was assessed using Jones’ criteria. Functional outcome was assessed at a mean of 3.4 years (2 to 7) post-operatively, using the Oxford knee score and the Short-form 12 score. Degenerative changes of the patellofemoral joint were seen pre-operatively in 125 knees (64%) on the skyline radiographs. There was no statistically significant difference in the Oxford knee or Short-form 12 scores between those patients who had patellofemoral osteoarthritis pre-operatively and those who did not (p = 0.22 and 0.54, respectively). These results support the opinion expressed at the designer’s hospital that degenerative changes of the patellofemoral joint in isolation should not be considered to be a contraindication to medial Oxford unicompartmental knee replacement.
Peri-prosthetic fracture after joint replacement in the lower limb is associated with significant morbidity. The primary aim of this study was to investigate the incidence of peri-prosthetic fracture after total hip replacement (THR) and total knee replacement (TKR) over a ten-year period using a population-based linked dataset. Between 1 April 1997 and 31 March 2008, 52 136 primary THRs, 8726 revision THRs, 44 511 primary TKRs, and 3222 revision TKRs were performed. Five years post-operatively, the rate of fracture was 0.9% after primary THR, 4.2% after revision THR, 0.6% after primary TKR and 1.7% after revision TKR. Comparison of survival analysis for all primary and revision arthroplasties showed peri-prosthetic fractures were more likely in females, patients aged >
70 and after revision arthroplasty. Female patients aged >
70 should be warned of a significantly increased risk of peri-prosthetic fracture after hip or knee replacement. The use of adjuvant medical treatment to reduce the effect of peri-prosthetic osteoporosis may be a direction of research for these patients.
We identified a series of 128 patients who had unilateral open reconstruction of the anterior cruciate ligament (ACL) by a single surgeon between 1993 and 2000. In all, 79 patients were reviewed clinically and radiologically eight to 15 years after surgery. Assessment included measurement of the Lysholm and Tegner scores, the ACL quality-of-life score and the Short Form-12 score, as well as the International Knee Documentation Committee clinical assessment, measurement of laxity by the KT-1000 arthrometer, a single-leg hop test and standardised radiography of both knees using the uninjured knee as a control. Of the injured knees, 46 (57%) had definite radiological evidence of osteoarthritis (Kellgren-Lawrence grade 2 or 3), with a mean difference between the injured and non-injured knees of 1.2 grades. The median ACL quality-of-life score was 80 (interquartile range (IQR) 60 to 90), the Lysholm score 84 (IQR 74 to 95), the Short Form-12 physical component score 54 (IQR 49 to 56) and the mean Hop Index 0.94 (0.52 to 1.52). In total 58 patients were graded as normal, 20 as nearly normal and one as abnormal on the KT-1000 assessment and pivot-shift testing. Taking the worst-case scenario of assuming all non-attenders (n = 48), two septic failures and one identified unstable knee found at review to be failures, the failure rate was 40%. Only two of the patients reviewed stated that they would not have similar surgery again. Open reconstruction of the ACL gives good, durable functional results, but with a high rate of radiologically evident osteoarthritis.