Advertisement for orthosearch.org.uk
Results 961 - 980 of 1756
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 788 - 792
1 Jun 2017
Bradley B Middleton S Davis N Williams M Stocker M Hockings M Isaac DL

Aims

Unicompartmental knee arthroplasty (UKA) has been successfully performed in the United States healthcare system on outpatients. Despite differences in healthcare structure and financial environment, we hypothesised that it would be feasible to replicate this success and perform UKA with safe day of surgery discharge within the NHS, in the United Kingdom. This has not been reported in any other United Kingdom centres.

Patients and Methods

We report our experience of implementing a pathway to allow safe day of surgery discharge following UKA. Data were prospectively collected on 72 patients who underwent UKA as a day case between December 2011 and September 2015.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 894 - 903
1 Jul 2017
Bonnin MP Saffarini M Nover L van der Maas J Haeberle C Hannink G Victor J

Aims

The morphometry of the distal femur was largely studied to improve bone-implant fit in total knee arthroplasty (TKA), but little is known about the asymmetry of the posterior condyles. This study aimed to investigate the dimensions of the posterior condyles and the influence of externally rotating the femoral component on potential prosthetic overhang or under-coverage.

Patients and Methods

We analysed the shape of 110 arthritic knees at the time of primary TKA using pre-operative CT scans. The height and width of each condyle were measured at the posterior femoral cut in neutral position, and in 3º and 5º of external rotation, using both central and medial referencing systems. We compared the morphological characteristics with those of 14 TKA models.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 806 - 811
1 Jun 2017
Takahashi N Sugaya H Matsuki K Miyauchi H Matsumoto M Tokai M Onishi K Hoshika S Ueda Y

Aims

The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear.

Patients and Methods

The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 25 - 28
1 Dec 2017


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1020 - 1026
1 Aug 2016
Śmigielski R Zdanowicz U Drwięga M Ciszek B Williams A

Anterior cruciate ligament (ACL) reconstruction is commonly performed and has been for many years. Despite this, the technical details related to ACL anatomy, such as tunnel placement, are still a topic for debate. In this paper, we introduce the flat ribbon concept of the anatomy of the ACL, and its relevance to clinical practice.

Cite this article: Bone Joint J 2016;98-B:1020–6.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 2 - 10
1 Dec 2017
Luokkala T Watts AC


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1620 - 1624
1 Dec 2016
Pailhé R Cognault J Massfelder J Sharma A Rouchy R Rubens-Duval B Saragaglia D

Aims

The role of high tibial osteotomy (HTO) is being questioned by the use of unicompartmental knee arthroplasty (UKA) in the treatment of medial compartment femorotibial osteoarthritis. Our aim was to compare the outcomes of revision HTO or UKA to a total knee arthroplasty (TKA) using computer-assisted surgery in matched groups of patients.

Patients and Methods

We conducted a retrospective study to compare the clinical and radiological outcome of patients who underwent revision of a HTO to a TKA (group 1) with those who underwent revision of a medial UKA to a TKA (group 2). All revision procedures were performed using computer-assisted surgery. We extracted these groups of patients from our database. They were matched by age, gender, body mass index, follow-up and pre-operative functional score. The outcomes included the Knee Society Scores (KSS), radiological outcomes and the rate of further revision.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 204 - 210
1 Feb 2017
Xu J Jia Y Kang Q Chai Y

Aims

To present our experience of using a combination of intra-articular osteotomy and external fixation to treat different deformities of the knee.

Patients and Methods

A total of six patients with a mean age of 26.5 years (15 to 50) with an abnormal hemi-joint line convergence angle (HJLCA) and mechanical axis deviation (MAD) were included. Elevation of a tibial hemiplateau or femoral condylar advancement was performed and limb lengthening with correction of residual deformity using a circular or monolateral Ilizarov frame.


Bone & Joint Research
Vol. 6, Issue 3 | Pages 162 - 171
1 Mar 2017
Walker JA Ewald TJ Lewallen E Van Wijnen A Hanssen AD Morrey BF Morrey ME Abdel MP Sanchez-Sotelo J

Objectives

Sustained intra-articular delivery of pharmacological agents is an attractive modality but requires use of a safe carrier that would not induce cartilage damage or fibrosis. Collagen scaffolds are widely available and could be used intra-articularly, but no investigation has looked at the safety of collagen scaffolds within synovial joints. The aim of this study was to determine the safety of collagen scaffold implantation in a validated in vivo animal model of knee arthrofibrosis.

Materials and Methods

A total of 96 rabbits were randomly and equally assigned to four different groups: arthrotomy alone; arthrotomy and collagen scaffold placement; contracture surgery; and contracture surgery and collagen scaffold placement. Animals were killed in equal numbers at 72 hours, two weeks, eight weeks, and 24 weeks. Joint contracture was measured, and cartilage and synovial samples underwent histological analysis.


Bone & Joint Research
Vol. 5, Issue 11 | Pages 586 - 593
1 Nov 2016
Rakhra KS Bonura AA Nairn R Schweitzer ME Kolanko NM Beaule PE

Objectives

The purpose of this study was to compare the thickness of the hip capsule in patients with surgical hip disease, either with cam-femoroacetabular impingement (FAI) or non-FAI hip pathology, with that of asymptomatic control hips.

Methods

A total of 56 hips in 55 patients underwent a 3Tesla MRI of the hip. These included 40 patients with 41 hips with arthroscopically proven hip disease (16 with cam-FAI; nine men, seven women; mean age 39 years, 22 to 58) and 25 with non-FAI chondrolabral pathology (four men, 21 women; mean age 40 years, 18 to 63) as well as 15 asymptomatic volunteers, whose hips served as controls (ten men, five women; mean age 62 years, 33 to 77). The maximal capsule thickness was measured anteriorly and superiorly, and compared within and between the three groups with a gender subanalysis using student’s t-test. The correlation between alpha angle and capsule thickness was determined using Pearson’s correlation coefficient.


Bone & Joint 360
Vol. 6, Issue 5 | Pages 24 - 27
1 Oct 2017


Bone & Joint 360
Vol. 6, Issue 5 | Pages 16 - 18
1 Oct 2017


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 16 - 21
1 Jan 2017
Aprato A Leunig M Massé A Slongo T Ganz R

Aims

Several studies have reported the safety and efficacy of subcapital re-alignment for patients with slipped capital femoral epiphysis (SCFE) using surgical dislocation of the hip and an extended retinacular flap. Instability of the hip and dislocation as a consequence of this surgery has only recently gained attention. We discuss this problem with some illustrative cases.

Materials and Methods

We explored the literature on the possible pathophysiological causes and surgical steps associated with the risk of post-operative instability and articular damage. In addition, we describe supplementary steps that could be used to avoid these problems.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 22 - 28
1 Jan 2017
Khan OH Malviya A Subramanian P Agolley D Witt JD

Aims

Periacetabular osteotomy is an effective way of treating symptomatic hip dysplasia. We describe a new minimally invasive technique using a modification of the Smith-Peterson approach.

We performed a prospective, longitudinal cohort study to assess for any compromise in acetabular correction when using this approach, and to see if the procedure would have a higher complication rate than that quoted in the literature for other approaches. We also assessed for any improvement in functional outcome.

Patients and Methods

From 168 consecutive patients (189 hips) who underwent acetabular correction between March 2010 and March 2013 we excluded those who had undergone previous pelvic surgery for DDH and those being treated for acetabular retroversion. The remaining 151 patients (15 men, 136 women) (166 hips) had a mean age of 32 years (15 to 56) and the mean duration of follow-up was 2.8 years (1.2 to 4.5). In all 90% of cases were Tönnis grade 0 or 1. Functional outcomes were assessed using the Non Arthritic Hip Score (NAHS), University of California, Los Angeles (UCLA) and Tegner activity scores.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims

Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA.

Patients and Methods

Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three.

Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89).


Bone & Joint Research
Vol. 5, Issue 7 | Pages 280 - 286
1 Jul 2016
Ozkurt B Sen T Cankaya D Kendir S Basarır K Tabak Y

Objectives

The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty.

Methods

The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, sd 9.4; 34 to 69). The ratios of the DMAD, PMAD, DLAD and PLAD to TEW were calculated.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 38 - 39
1 Aug 2017
Khan T


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1176 - 1182
1 Sep 2017
Berger P Van Cauter M Driesen R Neyt J Cornu O Bellemans J

Aims

The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS).

Patients and Methods

A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 475 - 482
1 Apr 2017
Hamilton TW Pandit HG Inabathula A Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims

While medial unicompartmental knee arthroplasty (UKA) is indicated for patients with full-thickness cartilage loss, it is occasionally used to treat those with partial-thickness loss. The aim of this study was to investigate the five-year outcomes in a consecutive series of UKAs used in patients with partial thickness cartilage loss in the medial compartment of the knee.

Patients and Methods

Between 2002 and 2014, 94 consecutive UKAs were undertaken in 90 patients with partial thickness cartilage loss and followed up independently for a mean of six years (1 to 13). These patients had partial thickness cartilage loss either on both femur and tibia (13 knees), or on either the femur or the tibia, with full thickness loss on the other surface of the joint (18 and 63 knees respectively). Using propensity score analysis, these patients were matched 1:2 based on age, gender and pre-operative Oxford Knee Score (OKS) with knees with full thickness loss on both the femur and tibia. The functional outcomes, implant survival and incidence of re-operations were assessed at one, two and five years post-operatively. A subgroup of 36 knees in 36 patients with partial thickness cartilage loss, who had pre-operative MRI scans, was assessed to identify whether there were any factors identified on MRI that predicted the outcome.


Bone & Joint 360
Vol. 5, Issue 4 | Pages 4 - 15
1 Aug 2016
Sehat K

Anatomical total knee arthroplasty alignment versus conventional mechanical alignment; or a combination?