Advertisement for orthosearch.org.uk
Results 781 - 800 of 1886
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1196 - 1198
1 Nov 2000
Hill PF Vedi V Williams A Iwaki H Pinskerova V Freeman MAR

In 13 unloaded living knees we confirmed the findings previously obtained in the unloaded cadaver knee during flexion and external rotation/internal rotation using MRI. In seven loaded living knees with the subjects squatting, the relative tibiofemoral movements were similar to those in the unloaded knee except that the medial femoral condyle tended to move about 4 mm forwards with flexion. Four of the seven loaded knees were studied during flexion in external and internal rotation. As predicted, flexion (squatting) with the tibia in external rotation suppressed the internal rotation of the tibia which had been observed during unloaded flexion


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1230 - 1237
1 Oct 2019
Kayani B Konan S Horriat S Ibrahim MS Haddad FS

Aims

The aim of this study was to assess the effect of posterior cruciate ligament (PCL) resection on flexion-extension gaps, mediolateral soft-tissue laxity, fixed flexion deformity (FFD), and limb alignment during posterior-stabilized (PS) total knee arthroplasty (TKA).

Patients and Methods

This prospective study included 110 patients with symptomatic osteoarthritis of the knee undergoing primary robot-assisted PS TKA. All operations were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess gaps before and after PCL resection in extension and 90° knee flexion. Measurements were made after excision of the anterior cruciate ligament and prior to bone resection. There were 54 men (49.1%) and 56 women (50.9%) with a mean age of 68 years (sd 6.2) at the time of surgery. The mean preoperative hip-knee-ankle deformity was 4.1° varus (sd 3.4).


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 4 | Pages 737 - 739
1 Nov 1963
Smith MGH

1. Twenty-three patients were treated by cross screwing for diastasis of the tibia and fibula in fractures at the ankle. 2. It is suggested that limitation of ankle dorsiflexion after this treatment was caused by the presence of a mechanical block to dorsiflexion by spur formation at the margins of tibia and talus. 3. An ordinary bone screw controlled the diastasis satisfactorily in twenty patients. 4. The screw did not interfere with movement at the inferior tibio-fibular joint because bone resorption about that part of the screw in the fibula allowed a small range of movement. 5. Discomfort from the screw was relieved by its removal


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 963 - 964
1 Nov 1996
Krettek C Blauth M Miclau T Rudolf J Könemann B Schandelmaier P

The accuracy of templates used for the preoperative planning of the fixation of intramedullary fractures depends on radiological magnification. To study the accuracy of these templates, we randomly selected 100 femoral and 100 tibial radiographs taken after stabilisation by an intramedullary nail using a standard technique. We then compared the known nail length with the corresponding measurements on the radiographs. The mean magnification factor for the femur was 9% and for the tibia 7%; these differ considerably from the range of magnification of the manufacturers’ templates (femur, 15% to 17%; tibia 10% to 15%). We conclude that templates are unreliable for the selection of implant length and that this should be done by intraoperative measurements


Aims

Enhanced perioperative protocols have significantly improved patient recovery following primary total knee arthroplasty (TKA). Little has been investigated the effectiveness of these protocols for revision TKA (RTKA). We report on a matched group of aseptic revision and primary TKA patients treated with an identical pain and rehabilitation programmes.

Methods

Overall, 40 aseptic full-component RTKA patients were matched (surgical date, age, sex, and body mass index (BMI)) to a group of primary cemented TKA patients. All RTKAs had new uncemented stemmed femoral and tibial components with metaphyseal sleeves. Both groups were treated with an identical postoperative pain protocol. Patients were followed for at least two years. Knee Society Scores (KSS) at six weeks and at final follow-up were recorded for both groups.


Bone & Joint Open
Vol. 1, Issue 2 | Pages 8 - 12
18 Feb 2020
Bhimani SJ Bhimani R Smith A Eccles C Smith L Malkani A

Aims

Robotic-assisted total knee arthroplasty (RA-TKA) has been introduced to provide accurate bone cuts and help achieve the target knee alignment, along with symmetric gap balancing. The purpose of this study was to determine if any early clinical benefits could be realized following TKA using robotic-assisted technology.

Methods

In all, 140 consecutive patients undergoing RA-TKA and 127 consecutive patients undergoing conventional TKA with minimum six-week follow-up were reviewed. Differences in visual analogue scores (VAS) for pain at rest and with activity, postoperative opiate usage, and length of stay (LOS) between the RA-TKA and conventional TKA groups were compared.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 145 - 150
1 Jun 2020
Hartzler MA Li K Geary MB Odum SM Springer BD

Aims

Two-stage exchange arthroplasty is the most common definitive treatment for prosthetic joint infection (PJI) in the USA. Complications that occur during treatment are often not considered. The purpose of this study was to analyze complications in patients undergoing two-stage exchange for infected total knee arthroplasty (TKA) and determine when they occur.

Methods

We analyzed all patients that underwent two-stage exchange arthroplasty for treatment of PJI of the knee from January 2010 to December 2018 at a single institution. We categorized complications as medical versus surgical. The intervals for complications were divided into: interstage; early post-reimplantation (three months); and late post-reimplantation (three months to minimum one year). Minimum follow-up was one year. In total, 134 patients underwent a first stage of a two-stage exchange. There were 69 males and 65 females with an mean age at first stage surgery of 67 years (37 to 89). Success was based on the new Musculoskeletal Infection Society (MSIS) definition of success reporting.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 795 - 803
1 Jun 2020
Tsuda Y Tsoi K Parry MC Stevenson JD Fujiwara T Sumathi V Jeys LM

Aims

To assess the correlation between the histological response to preoperative chemotherapy and event-free survival (EFS) or overall survival (OS) in patients with high-grade localized osteosarcoma.

Methods

Out of 625 patients aged ≤ 40 years treated for primary high-grade osteosarcoma between 1997 and 2016, 232 patients without clinically detectable metastases at the time of diagnosis and treated with preoperative high-dose methotrexate, adriamycin and cisplatin (MAP) chemotherapy and surgery were included. Associations of chemotherapy-induced necrosis in the resected specimen and EFS or OS were assessed using Cox model and the Pearson’s correlation coefficients (r). Time-dependent receiver operating characteristic analysis was applied to determine the optimal cut-off value of chemotherapy-induced necrosis for EFS and OS.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1193 - 1197
1 Sep 2008
El-Azab H Halawa A Anetzberger H Imhoff AB Hinterwimmer S

Radiographs of 110 patients who had undergone 120 high tibial osteotomies (60 closed-wedge, 60 open-wedge) were assessed for posterior tibial slope before and after operation, and before removal of the hardware. In the closed-wedge group the mean slope was 5.7° (. sd. 3.8) before and 2.4° (. sd. 3.9) immediately after operation, and 2.4° (. sd. 3.4) before removal of the hardware. In the open-wedge group, these values were 5.0° (. sd. 3.7), 7.7° (. sd. 4.3) and 8.1° (. sd. 3.9) respectively, when stabilised with a non-locking plate, and 7.7° (. sd. 3.5), 9.4° (. sd. 4.1) and 9.1° (. sd. 3.8), when stabilised with a locking plate. The reduction in slope (−2.7° (. sd. 4.1)) in the closed-wedge group and the increase (+2.5° (. sd. 3.4), in the open-wedge group was significantly different before and after operation (p = 0.002, p = 0.003). In no group were the changes in slope directly after operation and before removal of the hardware significant (p > 0.05). There was no correlation between the amount of correction in the frontal plane and the post-operative change in slope. Posterior tibial slope decreases after closed-wedge high tibial osteotomy and increases after an open-wedge procedure because of the geometry of the proximal tibia. The changes in the slope are stable over time, emphasising the influence of the operative procedure rather than of the implant


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 483 - 488
1 Apr 2005
Nakayama K Matsuda S Miura H Higaki H Otsuka K Iwamoto Y

We measured the contact areas and contact stresses at the post-cam mechanism of a posterior-stabilised total knee arthroplasty when a posterior force of 500 N was applied to the Kirschner Performance, Scorpio Superflex, NexGen LPS Flex Fixed, and NexGen LPS Flex Mobile knee systems. Measurements were made at 90°, 120°, and 150° of flexion both in neutral rotation and 10° of internal rotation of the tibial component. Peak contact stresses at 90°, 120°, and 150° were 24.0, 33.9, and 28.8 MPa, respectively, for the Kirschner; 26.0, 32.4, and 22.1 MPa, respectively, for the Scorpio; and 34.1, 31.5, and 32.5 MPa, respectively, for the NexGen LPS Flex Fixed. With an internally rotated tibia, the contact stress increased significantly with all the fixed-bearing arthroplasties but not with the NexGen LPS Flex Mobile arthroplasty. The post-cam design should be modified in order to provide a larger contact area whilst avoiding any impingement and edge loading


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 4 | Pages 597 - 600
1 Nov 1981
Minford A Hardy G Forsythe W Fitton J Rowe V

A 13-year-old girl presented with a two-year history of pain in the right thigh and right forearm. Engelmann's disease was diagnosed on the basis of radiological appearances and histological examination of the bone. Her symptoms subsided after biopsy of the bone, but two weeks later she developed severe pain in the left tibia and was unable to walk. Radiological features of Engelmann's disease were found in the left tibia and other long bones although these bones had been radiologically normal one month previously. Treatment with prednisolone gave rapid relief of pain and allowed the patient to become mobile again. Four months later the radiological appearances showed significant improvement. The use of corticosteroids in this disorder is discussed


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims

A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation.

Methods

This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded.


Bone & Joint Research
Vol. 8, Issue 11 | Pages 535 - 543
1 Nov 2019
Mohammad HR Campi S Kennedy JA Judge A Murray DW Mellon SJ

Objectives

The aim of this study was to determine the polyethylene wear rate of Phase 3 Oxford Unicompartmental Knee Replacement bearings and to investigate the effects of resin type and manufacturing process.

Methods

A total of 63 patients with at least ten years’ follow-up with three bearing types (1900 resin machined, 1050 resin machined, and 1050 resin moulded) were recruited. Patients underwent full weight-bearing model-based radiostereometric analysis to determine the bearing thickness. The linear wear rate was estimated from the change in thickness divided by the duration of implantation.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 497 - 503
1 May 2002
Hedström M åström K Sjöberg H Dalén N Sjöberg K Brosjö E

A total of 63 women who had an operation for a fracture of the hip was randomly allocated to one year of treatment either with anabolic steroids, vitamin D and calcium (anabolic group) or with calcium only (control group). The thigh muscle volume was measured by quantitative CT. The bone mineral density of the hip, femur and tibia was assessed by quantitative CT and dual-energy x-ray absorptiometry and of the heel by quantitative ultrasound. Quantitative CT showed that the anabolic group did not lose muscle volume during the first 12 months whereas the control group did (p< 0.01). There was less bone loss in the proximal tibia in the anabolic group than in the control group. The speed of gait and the Harris hip score were significantly better in the anabolic group after six and 12 months. Anabolic steroids, even in this moderate dose, given in combination with vitamin D and calcium had a beneficial effect on muscle volume, bone mineral density and clinical function in this group of elderly women


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 777 - 783
1 Nov 1988
Karrholm J Selvik G Elmqvist L Hansson L Jonsson H

Using roentgen stereophotogrammetry we have recorded the three-dimensional movements of the knee during an anteroposterior laxity test in 36 patients with torn anterior cruciate ligaments and in three cadaver knees. At 30 degrees of knee flexion and before loads were applied the tibia occupied a more laterally rotated position if the anterior cruciate ligament had been injured. When the tibia was pulled anteriorly knees with cruciate deficiency rotated more laterally and were more abducted than normal knees. Posterior traction induced lateral rotation in the injured knee and medial rotation in the intact one. Precise knowledge of the three-dimensional instability of the anterior cruciate deficient knee may be important when the laxity is evaluated only in relation to one of the three cardinal axes


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 407 - 411
1 May 1995
Court-Brown C Keating J Christie J McQueen M

Exchange nailing for failure of union after primary intramedullary nailing of the tibia is widely used but the indications and effectiveness have not been reported in detail. We have reviewed 33 cases of uninfected nonunion of the tibia treated by exchange nailing. This technique was successful without open bone grafting in all closed fractures and in open fractures of Gustilo types I, II and IIIa. The requirement for open bone grafting was reduced in type-IIIb fractures, but exchange nailing failed in type-IIIb fractures with significant bone loss. For these we recommend early open bone grafting. The most common complication was wound infection, seen more often than after primary nailing. We discuss our protocol for the use and timing of exchange nailing of all grades and types of tibial fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 960 - 963
1 Nov 1994
Guzzanti V Falciglia F Gigante A Fabbriciani C

We performed intra-articular reconstruction of the anterior cruciate ligament (ACL) with the semitendinosus tendon placed in 2 mm diameter tunnels in 21 skeletally immature rabbits. The operation caused 11% damage to the physis of the femur on the frontal plane and 3% of its cross-sectional area but no alteration of growth or axial deviation of the bone resulted. In the tibia, the operation caused 12% damage to the physis in the frontal plane and 4% of the cross-sectional area. Two tibiae developed valgus deformities and one was shortened. Histological examination showed no areas of epiphysiodesis. There was no abnormality of growth-plate thickness in the two cases of tibia valga. Osseous metaplasia in the grafted tendons did not occur. The results suggest the need for careful evaluation of the percentage of damage to the growth plate before using intra-articular methods for reconstruction of the anterior cruciate ligament in adolescents


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 500 - 506
1 Aug 1965
Makin M

1. A survey of 112 cases of residual poliomyelitis with leg shortening of 2·5 centimetres or more is reported. 2. In eighty-seven patients paralysed in early infancy the fibular shortening was greater than the tibial shortening. 3. The absence of the normal "to and fro" motion of the fibula causes delay in the appearance of the fibular epiphyses and retards fibular development. 4. The shortening of the fibula in infancy causes deformity at the ankle, in the tibia itself and at the knee. 5. At the ankle the poorly developed lateral malleolus causes wedging of the lower tibial epiphysis and valgus at the ankle, which is often unstable. 6. At the knee progressive genu valgum is produced and in the tibia lateral torsion occurs. 7. The clinical significance of these deformities in relation to reconstructive procedures is stressed


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 560 - 565
1 Aug 1989
Cooke T Pichora D Siu D Scudamore R Bryant J

Some arthritic knees with varus deformity show excessive valgus angulation of the femoral joint surface with proximal tibia vara. This causes a downward and medial inclination of the articular surfaces in the coronal plane. The patients we studied had a medial shift of the standing load-bearing axis, and arthritic changes mainly in the medial compartment. Some also had lateral tibial subluxation with twisting of the distal femur and proximal tibia in opposite directions. We assessed the articular geometry by precise radiographic analysis, and compared the results with those in normal volunteers and a group of osteoarthritic patients. The prevalence of this type of deformity in our osteoarthritic patients was 11.5%; its recognition allows the use of specific operative correction that may include double osteotomy or the precise orientation of prosthetic components


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 239 - 243
1 May 1981
Young A Kinsella P Boland P

Thirteen patients suffering from rheumatoid arthritis had 19 stress fractures of the tibia or fibula. These patients characteristically presented with sudden, severe, unexplained pain with localised tenderness just below the knee or above the ankle. In seven patients examination of the adjacent joint indicated a flare-up of disease activity or a pyogenic arthritis. In six patients the diagnosis was delayed by the late appearance of callus in minute fractures. All patients had rheumatoid deformities of the ipsilateral lower limb: valgus deformities of the knee and subtalar joints occurred most frequently. All patients had osteoporosis; all except two had received steroid treatment and five had abnormalities of calcium metabolism. We suggest that deformities of the knee and ankle predispose patients with rheumatoid arthritis and osteoporosis to stress fractures of the tibia and fibula