Advertisement for orthosearch.org.uk
Results 61 - 80 of 259
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 76 - 78
1 Jan 1993
Carr A Jefferson R Benson M

We measured the range of rotation in both hips of 397 normal children and in the unaffected hip of 135 children with unilateral congenital dislocation of the hip. Both groups were assessed for generalised joint laxity. Joint laxity was more common in normal children with an internally centred arc of hip rotation than in normal children with a neutral or an externally rotated arc. The children with congenitally dislocated hips had significantly more joint laxity than did the control group and significantly more of them had an internally centred arc of hip rotation. We suggest that the lax joint capsule fails to mould away the neonatal anteversion of the femoral neck during the first few months of life


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 719 - 721
1 Nov 1985
Kumar V Balasubramaniam P

The role of atmospheric pressure in providing static stability of the shoulder was studied experimentally in 24 cadaveric shoulders. Atmospheric air was allowed to enter the joint after puncturing the capsule. Three types of experiment were performed: in the first, the capsule was punctured after sequential division of the muscles; in the second, atmospheric air was let in by percutaneous puncture of of the capsule without dividing the muscles; and in the third, air was first let into the joint by percutaneous puncture of the capsule and then the muscles of the shoulder were divided. It was found that the intact shoulder subluxated after percutaneous puncture even without division of the overlying muscles or the capsule. Our findings suggest that negative pressure and muscle tone are the main static stabilisers of the shoulder, rather than the joint capsule


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 4 | Pages 578 - 589
1 Nov 1972
Colton CL

1. The results of Chiari pelvic osteotomy have been examined two to six years after operation in a group of eighteen patients with persisting acetabular dysplasia in the second and third decades. 2. The analysis suggests that for a good clinical result it is essential to create a relationship of the new outer acetabular lip to the original lip so that the CE angle is between 20 and 40 degrees and the roof angle is between 10 degrees below and 20 degrees above the horizontal. 3. This may be achieved by a pelvic osteotomy immediately above the joint capsule, angled 10 degrees upwards and inwards and displaced by 50 per cent of the pelvic thickness. 4. Details of the operative technique using a Smith-Petersen approach are presented


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 226 - 235
1 May 1960
Harrold AJ

The hypothesis provides a theoretical justification for, and re-emphasises the practical importance of, close reduction and strict immobilisation in the treatment of fractures of the neck of the femur. It does not support the view that failure of union is caused by vascular damage at the time of the original injury. Unexpected failure of union after nailing is more likely caused by unrecognised imperfection of reduction and the acknowledged deficiencies of internal fixation. Attempts to improve results by passing the sartorius muscle around the fracture (Adams 1956), or by attaching muscle or joint capsule to the proximal fragment, have failed, because such soft tissues are swept off by the acetabular rim when the hip is flexed or medially rotated. Further work is required, both on the more detailed biochemistry of haemarthroses and on the practical and wider implications of the hypothesis


Bone & Joint Research
Vol. 10, Issue 8 | Pages 474 - 487
2 Aug 2021
Duan M Wang Q Liu Y Xie J

Transforming growth factor-beta2 (TGF-β2) is recognized as a versatile cytokine that plays a vital role in regulation of joint development, homeostasis, and diseases, but its role as a biological mechanism is understood far less than that of its counterpart, TGF-β1. Cartilage as a load-resisting structure in vertebrates however displays a fragile performance when any tissue disturbance occurs, due to its lack of blood vessels, nerves, and lymphatics. Recent reports have indicated that TGF-β2 is involved in the physiological processes of chondrocytes such as proliferation, differentiation, migration, and apoptosis, and the pathological progress of cartilage such as osteoarthritis (OA) and rheumatoid arthritis (RA). TGF-β2 also shows its potent capacity in the repair of cartilage defects by recruiting autologous mesenchymal stem cells and promoting secretion of other growth factor clusters. In addition, some pioneering studies have already considered it as a potential target in the treatment of OA and RA. This article aims to summarize the current progress of TGF-β2 in cartilage development and diseases, which might provide new cues for remodelling of cartilage defect and intervention of cartilage diseases.


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 289 - 296
1 Aug 1975
Jones DA Lucas HK O"Driscoll M Price CHG Wibberley B

The significance of cobalt as a cause of symptoms after McKee hip arthroplasty is discussed. Seven patients are described in whom such arthroplasties became unsatisfactory after periods varying from nine months to four years. Six of these patients were cobalt-positive but nickel-and chrome-negative on patch testing. Macroscopic and histological necrosis of bone, muscle and joint capsule around the prostheses was found in five patients whose hips were explored. The symptoms were progressive pain, a feeling of instability, and in two cases spontaneous dislocation. Radiological features included acetabular fracture, bone resorption, loosening and dislocation of the prosthesis. Increased cobalt concentrations (determined by atomic absorption spectrophotometry) in the urine of four patients and in a variety of tissues in one patient are presented. Patch testing is recommended in the investigation of patients with troublesome McKee hip arthroplasties


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 750 - 754
1 Sep 1993
Klaue K Sherman M Perren S Wallin A Looser C Ganz R

The Chiari osteotomy and various shelf procedures are used to augment the weight-bearing area in dysplastic acetabula. The new articular surface derives by metaplasia from the acetabular rim and joint capsule, and is therefore of poorer quality than congruous hyaline cartilage. We reviewed 32 patients after augmentation procedures, using conventional radiographs and three-dimensional reconstruction from CT scans. We showed that Chiari osteotomy and shelf procedures generally achieve less than complete cover, especially over the posterolateral quadrant of the femoral head. Our results suggest that alternative methods which reorientate the whole of the acetabulum are the treatment of choice. Augmentation procedures remain as a salvage option when reorientation is inappropriate or the original hyaline cartilage surface is absent, as in subluxed joints with a secondary acetabulum. Computerised assessment is recommended before operation to assess existing cover and the possible extent of provision of new cover


Bone & Joint Open
Vol. 3, Issue 1 | Pages 4 - 11
3 Jan 2022
Argyrou C Tzefronis D Sarantis M Kateros K Poultsides L Macheras GA

Aims

There is evidence that morbidly obese patients have more intra- and postoperative complications and poorer outcomes when undergoing total hip arthroplasty (THA) with the direct anterior approach (DAA). The aim of this study was to determine the efficacy of DAA for THA, and compare the complications and outcomes of morbidly obese patients with nonobese patients.

Methods

Morbidly obese patients (n = 86), with BMI ≥ 40 kg/m2 who underwent DAA THA at our institution between September 2010 and December 2017, were matched to 172 patients with BMI < 30 kg/m2. Data regarding demographics, set-up and operating time, blood loss, radiological assessment, Harris Hip Score (HHS), International Hip Outcome Tool (12-items), reoperation rate, and complications at two years postoperatively were retrospectively analyzed.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 24 - 35
1 Feb 1977
McDevitt C Gilbertson E Muir H

An experimental model of osteoarthritis resulting from laxity of the joint was induced in eighteen mature dogs (at least two years old) by sectioning the anterior cruciate ligament of the right knee (stifle) with a stab incision, the left knee providing a control. A sham operation was also performed in three other dogs, in which a stab incision was made but the ligament left intact. The dogs were killed at various intervals from one to forty-eight weeks later. Morphological changes in bone, cartilage, synovial membrane and joint capsule were examined in all the joints and biochemical changes in the cartilage of three dogs killed after two, eight, and sixteen weeks. All the changes resulting from the operation progressed with time and became indistinguishable from those found in three dogs with natural osteoarthritis of the knee. There were no changes in the joints which had sham operations. As the time of onset is known, this experimental model in a larger species enables a study to be made of the biochemical as well as the morphological changes in the early stages of osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 163 - 166
1 Jan 1999
Nivbrant B Karlsson K Kärrholm J

We analysed synovial fluid from 88 hips, 38 with osteoarthritis and 12 with well-functioning and 38 with loose hip prostheses. The levels of TNF-α, IL-1ß (71 hips) and IL-6 (45 hips) were measured using the ELISA technique. Joints with well-functioning or loose prostheses had significantly increased levels of TNF-α compared with those with osteoarthritis. Hips with aseptic loosening also had higher levels of IL-1ß but not of IL-6 compared with those without an implant. The levels of TNF-α and IL-1ß did not differ between hips with stable and loose prostheses. Higher levels of TNF-α were found in hips with bone resorption of type II and type III (Gustilo-Pasternak) compared with those with type-I loosening. The level of cytokines in joint fluid was not influenced by the time in situ of the implants or the age, gender or area of the osteolysis as measured on conventional radiographs. Our findings support the theory that macrophages in the joint capsule increase the production of TNF-α at an early phase probably because of particle load and in the absence of clinical loosening. Since TNF-α has an important role in the osteolytic process, the interfaces should be protected from penetration of joint fluid


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 53 - 56
1 Jan 1991
Barrett D Cobb A Bentley G

We measured joint position sense in the knee by a new method which tests the proprioceptive contribution of the joint capsule and ligaments. The leg was supported on a splint, and held in several positions of flexion. The subjects' perception of the position was recorded on a visual analogue model and compared with the actual angle of flexion. Eighty-one normal and 45 osteoarthritic knees were examined, as were 10 knees with semi-constrained and 11 with hinged joint replacements. All were assessed with and without an elastic bandage around the knee. There was a steady decline in joint position sense with age in subjects with normal knees. Those with osteoarthritic knees had impaired joint position sense at all ages (p less than 0.001). Knee replacement improved the joint position sense slightly (p less than 0.02); semi-constrained replacement had a greater effect than hinged replacement. The effect of an elastic bandage in subjects with poor position sense was dramatic, improving accuracy by 40% (p less than 0.001). It is proposed that reduced proprioception in elderly and osteoarthritic subjects may be responsible for initiation or advancement of degeneration of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 679 - 683
1 Jul 2000
Gautier E Ganz K Krügel N Gill T Ganz R

The primary source for the blood supply of the head of the femur is the deep branch of the medial femoral circumflex artery (MFCA). In posterior approaches to the hip and pelvis the short external rotators are often divided. This can damage the deep branch and interfere with perfusion of the head. We describe the anatomy of the MFCA and its branches based on dissections of 24 cadaver hips after injection of neoprene-latex into the femoral or internal iliac arteries. The course of the deep branch of the MFCA was constant in its extracapsular segment. In all cases there was a trochanteric branch at the proximal border of quadratus femoris spreading on to the lateral aspect of the greater trochanter. This branch marks the level of the tendon of obturator externus, which is crossed posteriorly by the deep branch of the MFCA. As the deep branch travels superiorly, it crosses anterior to the conjoint tendon of gemellus inferior, obturator internus and gemellus superior. It then perforates the joint capsule at the level of gemellus superior. In its intracapsular segment it runs along the posterosuperior aspect of the neck of the femur dividing into two to four subsynovial retinacular vessels. We demonstrated that obturator externus protected the deep branch of the MFCA from being disrupted or stretched during dislocation of the hip in any direction after serial release of all other soft-tissue attachments of the proximal femur, including a complete circumferential capsulotomy. Precise knowledge of the extracapsular anatomy of the MFCA and its surrounding structures will help to avoid iatrogenic avascular necrosis of the head of the femur in reconstructive surgery of the hip and fixation of acetabular fractures through the posterior approach


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 4 | Pages 560 - 571
1 Nov 1949
Watson-Jones R

1. Léri's pleonosteosis is characterised by broadening and deformity of the thumbs and great toes, flexion contracture of the interphalangeal joints, limited movement of other joints, and often a Mongoloid facies. Four such cases are described. 2. A review of the twenty reports in the literature, and the cases now described, shows that the deformities are due to capsular contracture rather than deformity of bone. 3. In one patient there was striking evidence of fibro-cartilaginous thickening of the anterior carpal ligaments. It is suggested that the primary pathological change in pleonosteosis may be in the joint capsules rather than in the epiphyses. 4. The patient with thickening of the anterior carpal ligaments had bilateral median palsy from carpal tunnel compression. 5. The causes of carpal tunnel compression of the median nerve are reviewed. Acute compression may be due not only to dislocation of the semilunar bone but to haemorrhage in the palm. Late compression by bone may occur twenty to fifty years after injury. Late compression without bone abnormality has been attributed to occupational stress, but it is suggested that pathological thickening of the anterior carpal ligament may be the cause. 6. The patient with pleonosteosis and bilateral median palsy had also bilateral Morton's metatarsalgia with large digital neuromata. 7. Plantar digital neuritis has already been shown to be an ischaemic nerve lesion preceded by degenerative changes in the digital artery. The significance of the fibrous tunnel through which the artery passes to reach the digital cleft is considered


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 128 - 136
1 Jan 2002
Böhler M Kanz F Schwarz B Steffan I Walter A Plenk H Knahr K

We revised seven alumina-blasted cementless hip prostheses (Ti-alloy stems, cp Ti threaded sockets) with low- or high-carbon Co-alloy bearings at a mean of 20.1 months after implantation because of pain and loosening. Histological examination of the retrieved periprosthetic tissues from two cases in which the implant was stable and three in which the socket was loose showed macrophages with basophilic granules containing metal and alumina wear particles and lymph-cell infiltrates. In one of the two cases of stem loosening the thickened neocapsule also contained definite lymphatic follicles and gross lymphocyte/plasma-cell infiltrates. Spectrometric determination of the concentration of elements in periprosthetic tissues from six cases was compared with that of joint capsules from five control patients undergoing primary hip surgery. In the revisions the mean concentration of implant-relevant elements was 693.85 μg/g dry tissue. In addition to Cr (15.2%), Co (4.3%), and Ti (10.3%), Al was predominant (68.1%) and all concentrations were significantly higher (p < 0.001) than those in the control tissues. The annual rates of linear wear were calculated for six implants. The mean value was 11.1 μm (heads 6.25 μm, inserts 4.82 μm). SEM/EDXA showed numerous fine scratches and deep furrows containing alumina particles in loosened sockets, and stems showed contamination with adhering or impacted alumina particles of between 2 and 50 μm in size


Bone & Joint Research
Vol. 10, Issue 6 | Pages 354 - 362
1 Jun 2021
Luo Y Zhao X Yang Z Yeersheng R Kang P

Aims

The purpose of this study was to examine the efficacy and safety of carbazochrome sodium sulfonate (CSS) combined with tranexamic acid (TXA) on blood loss and inflammatory responses after primary total hip arthroplasty (THA), and to investigate the influence of different administration methods of CSS on perioperative blood loss during THA.

Methods

This study is a randomized controlled trial involving 200 patients undergoing primary unilateral THA. A total of 200 patients treated with intravenous TXA were randomly assigned to group A (combined intravenous and topical CSS), group B (topical CSS), group C (intravenous CSS), or group D (placebo).


Bone & Joint Research
Vol. 10, Issue 10 | Pages 693 - 703
1 Oct 2021
Wang X Wang D Xia P Cheng K Wang Q Wang X Lin Q Song J Chen A Li X

Aims

To evaluate the effect of ultrasound-targeted simvastatin-loaded microbubble destruction (UTMDSV) for alleviation of the progression of osteoarthritis (OA) in rabbits through modulation of the peroxisome proliferator-activated receptor (PPARγ).

Methods

In vitro, OA chondrocytes were treated with ultrasound (US), US-targeted microbubble destruction (UTMD), simvastatin (SV), and UTMDSV on alternate days for four weeks. Chondrocytes were also treated with PPARγ inhibitor, PPARγ inhibitor+ UTMDSV, and UTMDSV. The cholesterol efflux rate and triglyceride levels were measured using an assay kit and oil red O staining, respectively. In vivo, the OA rabbits were treated with a single intra-articular injection of UTMD, SV, and UTMDSV every seven days for four weeks. Cartilage histopathology was assessed by safranin-O staining and the Mankin score. Total cholesterol (TC) and high-density lipoprotein-cholesterol (HDL-C) in rabbit knee synovial fluid were detected by enzyme-marker assay. Aggrecan, collagen II, and PPARγ expression levels were analyzed by Western blotting (WB).


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 4 | Pages 627 - 642
1 Nov 1953
Lloyd-Roberts GC

1. The synovial membrane and capsule in osteoarthritis of the hip have been studied in twenty-five cases. Dissections have been made on fresh cadavers to establish the normal structure and function of these tissues at different ages. 2. Fragments of bone and cartilage were found beneath the synovial surface in twenty-three cases of the twenty-five cases of osteoarthritis. 3. The source of these fragments is the degenerate articular surfaces. 4. The fibrosis of the synovial membrane and capsule follows the synovial hyperplasia which accompanies the phagocytosis of these fragments. 5. A similar histological picture has been produced by injecting fragmented cartilage into the knee joints of rabbits. The injected fragments are found beneath the surface, and synovial hyperplasia is followed by subsynovial fibrosis. 6. The greatest amount of this joint debris is found in the lowest part of the joint cavity. 7. The joint capsule is particularly sensitive to traction. 8. All parts of the capsule are tight in extension, which is the weight-bearing position. 9. Fibrotic shortening of the capsule in the lowest part of the joint cavity explains many of the symptoms and signs of the disease: pain is caused by an attempt to stretch the capsule; muscle spasm occurs in the muscles supplied by the sensory nerves of this part of the capsule; extension, medial rotation and abduction, which tighten this area, are lost first; progressive shortening causes deformity in the opposite direction, namely flexion, lateral rotation and adduction; the loss of extension causes a more rapid wearing of articular cartilage on weight bearing; subperiosteal new bone is formed on the under-surface of the neck of the femur. 10. The symptomatology is discussed


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1367 - 1372
1 Aug 2021
Plancher KD Brite JE Briggs KK Petterson SC

Aims

The patient-acceptable symptom state (PASS) is a level of wellbeing, which is measured by the patient. The aim of this study was to determine if the proportion of patients who achieved an acceptable level of function (PASS) after medial unicompartmental knee arthroplasty (UKA) was different based on the status of the anterior cruciate ligament (ACL) at the time of surgery.

Methods

A total of 114 patients who underwent UKA for isolated medial osteoarthritis (OA) of the knee were included in the study. Their mean age was 65 years (SD 10). No patient underwent a bilateral procedure. Those who had undergone ACL reconstruction during the previous five years were excluded. The Knee injury Osteoarthritis Outcome Score Activities of Daily Living (KOOS ADL) function score was used as the primary outcome measure with a PASS of 87.5, as described for total knee arthroplasty (TKA). Patients completed all other KOOS subscales, Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the Veterans Rand 12-item health survey score. Failure was defined as conversion to TKA.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 17 - 27
1 Jan 2000
Zadeh HG Catterall A Hashemi-Nejad A Perry RE

After open reduction for developmental dysplasia of the hip (DDH), a pelvic or femoral osteotomy may be required to maintain a stable concentric reduction. We report the clinical and radiological outcome in 82 children (95 hips) with DDH treated by open reduction through an anterior approach in which a test of stability was used to assess the need for a concomitant osteotomy. The mean age at the time of surgery was 28 months (9 to 79) and at the latest follow-up, 17 years (12 to 25). All patients have been followed up until closure of the triradiate cartilage with a mean period of 15 years (8 to 23). At the time of open reduction before closure of the joint capsule, the position of maximum stability was assessed. A hip which required flexion with abduction for stability was considered to need an innominate osteotomy. If only internal rotation and abduction were required, an upper femoral derotational and varus osteotomy was carried out. For a ‘double-diameter’ acetabulum with anterolateral deficiency, a Pemberton-type osteotomy was used. A hip which was stable in the neutral position required no concomitant osteotomy. Overall, 86% of the patients have had a satisfactory radiological outcome (Severin groups I and II) with an incidence of 7% of secondary procedures for persistent dysplasia including one hip which redislocated. The results were better (p = 0.04) in children under the age of two years. Increased leg length on the affected side was associated with poor acetabular development and recurrence of joint dysplasia (p = 0.01). The incidence of postoperative avascular necrosis was 7%. In a further 18%, premature physeal arrest was noted during the adolescent growth spurt (Kalamchi-MacEwen types II and III). Both of these complications were also associated with recurrence of joint dysplasia (p = 0.01). Studies with a shorter follow-up are therefore likely to underestimate the proportion of poor radiological results


Bone & Joint 360
Vol. 10, Issue 2 | Pages 5 - 16
1 Apr 2021
Coco V Shivji F Thompson P Grassi A Zaffagnini S Spalding T