Periprosthetic femoral fractures (PFF) following total hip arthroplasty
(THA) are devastating complications that are associated with functional
limitations and increased overall mortality. Although cementless
implants have been associated with an increased risk of PFF, the
precise contribution of implant geometry and design on the risk
of both intra-operative and post-operative PFF remains poorly investigated.
A systematic review was performed to aggregate all of the PFF literature
with specific attention to the femoral implant used. A systematic search strategy of several journal databases and
recent proceedings from the American Academy of Orthopaedic Surgeons
was performed. Clinical articles were included for analysis if sufficient
implant description was provided. All articles were reviewed by
two reviewers. A review of fundamental investigations of implant
load-to-failure was performed, with the intent of identifying similar
conclusions from the clinical and fundamental literature.Aims
Patients and Methods
It is widely held that most Baker’s cysts resolve after treatment
of the intra-articular knee pathology. The present study aimed to
evaluate the fate of Baker’s cysts and their associated symptoms
after total knee arthroplasty (TKA). In this prospective cohort study, 102 patients with (105 were
included, however three were lost to follow-up) an MRI-verified
Baker’s cyst, primary osteoarthritis and scheduled for TKA were
included. Ultrasound was performed to evaluate the existence and
the gross size of the cyst before and at one year after TKA. Additionally,
associated symptoms of Baker's cyst were recorded pre- and post-operatively.Aims
Patients and Methods
Salubrinal is a synthetic agent that elevates phosphorylation
of eukaryotic translation initiation factor 2 alpha (eIF2α) and
alleviates stress to the endoplasmic reticulum. Previously, we reported
that in chondrocytes, Salubrinal attenuates expression and activity
of matrix metalloproteinase 13 (MMP13) through downregulating nuclear
factor kappa B (NFκB) signalling. We herein examine whether Salubrinal
prevents the degradation of articular cartilage in a mouse model
of osteoarthritis (OA). OA was surgically induced in the left knee of female mice. Animal
groups included age-matched sham control, OA placebo, and OA treated
with Salubrinal or Guanabenz. Three weeks after the induction of
OA, immunoblotting was performed for NFκB p65 and p-NFκB p65. At
three and six weeks, the femora and tibiae were isolated and the sagittal
sections were stained with Safranin O.Objectives
Methods
The aim of this study was to analyse human muscle tissue before
and after rotator cuff repair to look for evidence of regeneration,
and to characterise the changes seen in the type of muscle fibre. Patients were assessed pre-operatively and one year post-operatively
using the Oxford Shoulder Score (OSS) and MRI. The cross-sectional
area and distribution of the type of muscle fibre were assessed
on biopsies, which were taken at surgery and one year post-operatively.
Paired samples from eight patients were analysed. There were three
men and five women with a mean age of 63 years (50 to 73).Aims
Patients and Methods
The aim of this study was to analyse the gait
pattern, muscle force and functional outcome of patients who had undergone
replacement of the proximal tibia for tumour and alloplastic reconstruction
of the extensor mechanism using the patellar-loop technique. Between February 1998 and December 2009, we carried out wide
local excision of a primary sarcoma of the proximal tibia, proximal
tibial replacement and reconstruction of the extensor mechanism
using the patellar-loop technique in 18 patients. Of these, nine
were available for evaluation after a mean of 11.6 years (0.5 to
21.6). The strength of the knee extensors was measured using an
Isobex machine and gait analysis was undertaken in our gait assessment
laboratory. Functional outcome was assessed using the American Knee
Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores. The gait pattern of the patients differed in ground contact time,
flexion heel strike, maximal flexion loading response and total
sagittal plane excursion. The mean maximum active flexion was 91°
(30° to 110°). The overall mean extensor lag was 1° (0° to 5°).
The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that
in the non-operated leg (p <
0.001). The mean functional scores
were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional
score). In summary, the results show that reconstruction of the extensor
mechanism using this technique gives good biomechanical and functional
results. The patients’ gait pattern is close to normal, except for
a somewhat stiff knee gait pattern. The strength of the extensor
mechanism is reduced, but sufficient for walking. Cite this article:
We report the results of Vulpius transverse gastrocsoleus
recession for equinus gait in 26 children with cerebral palsy (CP),
using the Gait Profile Score (GPS), Gait Variable Scores (GVS) and
movement analysis profile. All children had an equinus deformity
on physical examination and equinus gait on three-dimensional gait
analysis prior to surgery. The pre-operative and post-operative
GPS and GVS were statistically analysed. There were 20 boys and
6 girls in the study cohort with a mean age at surgery of 9.2 years
(5.1 to 17.7) and 11.5 years (7.3 to 20.8) at follow-up. Of the
26 children, 14 had spastic diplegia and 12 spastic hemiplegia.
Gait function improved for the cohort, confirmed by a decrease in
mean GPS from 13.4° pre-operatively to 9.0° final review (p <
0.001). The change was 2.8 times the minimal clinically important
difference (MCID). Thus the improvements in gait were both clinically and
statistically significant. The transverse gastrocsoleus recession
described by Vulpius is an effective procedure for equinus gait
in selected children with CP, when there is a fixed contracture
of the gastrocnemius and soleus muscles. Cite this article:
We hypothesised that the removal of the subchondral
bone plate (SCBP) for cemented acetabular component fixation in
total hip arthroplasty (THA) offers advantages over retention by
improving the cement-bone interface, without jeopardising implant
stability. We have previously published two-year follow-up data
of a randomised controlled trial (RCT), in which 50 patients with
primary osteoarthritis were randomised to either retention or removal
of the SCBP. The mean age of the retention group (n = 25, 13 males)
was 70.0 years ( Cite this article:
The degree of displacement of a fracture of the distal radius
is an important factor which can be assessed using simple radiographic
measurements. Our aim was to investigate the reliability and reproducibility
of these measurements and to determine if they should be used clinically. A 10% sample was randomly generated from 3670 consecutive adult
patients who had presented to University Hospitals of Leicester
NHS Trust between 2007 and 2010 with a fracture of the distal radius.
Radiographs of the 367 patients were assessed by two independent
reviewers. Four measurements of displacement of the fracture were recorded
and the inter-observer correlation assessed using the intra-class
correlation coefficient.Aims
Patients and Methods
This study tests the biomechanical properties of adjacent locked
plate constructs in a femur model using Sawbones. Previous studies
have described biomechanical behaviour related to inter-device distances.
We hypothesise that a smaller lateral inter-plate distance will
result in a biomechanically stronger construct, and that addition
of an anterior plate will increase the overall strength of the construct. Sawbones were plated laterally with two large-fragment locking
compression plates with inter-plate distances of 10 mm or 1 mm.
Small-fragment locking compression plates of 7-hole, 9-hole, and
11-hole sizes were placed anteriorly to span the inter-plate distance.
Four-point bend loading was applied, and the moment required to
displace the constructs by 10 mm was recorded.Objectives
Methods
The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos
R) bone cement is no longer commercially available and was superseded
by Refobacin bone cement R and Palacos R + G in 2005. However, the
performance of these newly introduced bone cements have not been
tested in a phased evidence-based manner, including roentgen stereophotogrammetric
analysis (RSA). In this blinded, randomised, clinical RSA study, the migration
of the Stanmore femoral component was compared between Refobacin
bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties.
The primary outcome measure was femoral component migration measured
using RSA and secondary outcomes were Harris hip score (HHS), Hip
disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D)
and Short Form 36 (SF-36).Aims
Patients and Methods
Demineralised bone matrix (DBM) is rarely used for the local
delivery of prophylactic antibiotics. Our aim, in this study, was
to show that a graft with a bioactive glass and DBM combination,
which is currently available for clinical use, can be loaded with
tobramycin and release levels of antibiotic greater than the minimum
inhibitory concentration for Antibiotic was loaded into a graft and subsequently evaluated
for drug elution kinetics and the inhibition of bacterial growth.
A rat femoral condylar plug model was used to determine the effect
of the graft, loaded with antibiotic, on bone healing.Aims
Materials and Methods
Our aim was to investigate the outcomes of patients with a displaced
fracture of the glenoid fossa who are treated conservatively. There
is little information in the literature about the treatment of these
rare injuries non-operatively. We reviewed 24 patients with a mean age of 52 years (19 to 81)
at a mean of 5.6 years (11 months to 18 years) after the injury.Aims
Patients and Methods
Loosening of pedicle screws is a major complication of posterior
spinal stabilisation, especially in the osteoporotic spine. Our
aim was to evaluate the effect of cement augmentation compared with
extended dorsal instrumentation on the stability of posterior spinal
fixation. A total of 12 osteoporotic human cadaveric spines (T11-L3) were
randomised by bone mineral density into two groups and instrumented
with pedicle screws: group I (SHORT) separated T12 or L2 and group
II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were
augmented with cement unilaterally in each vertebra. Fatigue testing
was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz)
load with stepwise increasing peak force.Aims
Materials and Methods
We present the clinical and radiographic outcome of 81 children
with Gartland type I to III supracondylar humeral fractures at a
minimum follow-up of ten years (mean 12.1 years; 10.3 to 16.1) following
injury. The clinical and functional outcomes are compared with normal
age- and gender-matched individuals. The population-based study
setting was first identified from the institutional registries;
the rate of participation was 76%. Controls were randomly selected
from Finnish National Population Registry.Aims
Patients and Methods
The restoration of knee alignment is an important
goal during total knee arthroplasty (TKA). In the past surgeons aimed
to restore neutral limb alignment during surgery. However, previous
studies have demonstrated alignment to be dynamic, varying depending
on the position of the limb and the degree of weight-bearing, and
between patients. We used a validated computer navigation system
to measure the femorotibial mechanical angle (FTMA) in 264 knees in
77 male and 55 female healthy volunteers aged 18 to 35 years (mean
26.2). We found the mean supine alignment to be a varus angle of
1.2° (standard deviation ( Knee alignment is different in different individuals and is dynamic
in nature, changing with different postures. This may have implications
for the assessment of alignment in TKA, which is achieved in non-weight-bearing conditions
and which may not represent the situation observed during weight-bearing. Cite this article:
Anterior cruciate ligament (ACL) reconstruction
is commonly performed and has been for many years. Despite this, the
technical details related to ACL anatomy, such as tunnel placement,
are still a topic for debate. In this paper, we introduce the flat
ribbon concept of the anatomy of the ACL, and its relevance to clinical
practice. Cite this article:
Chronic osteomyelitis may recur if dead space management, after
excision of infected bone, is inadequate. This study describes the
results of a strategy for the management of deep bone infection
and evaluates a new antibiotic-loaded biocomposite in the eradication
of infection from bone defects. We report a prospective study of 100 patients with chronic osteomyelitis,
in 105 bones. Osteomyelitis followed injury or surgery in 81 patients.
Nine had concomitant septic arthritis. 80 patients had comorbidities
(Cierny-Mader (C-M) Class B hosts). Ten had infected nonunions. All patients were treated by a multidisciplinary team with a
single-stage protocol including debridement, multiple sampling,
culture-specific systemic antibiotics, stabilisation, dead space
filling with the biocomposite and primary skin closure. Aims
Patients and Methods
Tibial nonunion represents a spectrum of conditions
which are challenging to treat, and optimal management remains unclear
despite its high rate of incidence. We present 44 consecutive patients
with 46 stiff tibial nonunions, treated with hexapod external fixators
and distraction to achieve union and gradual deformity correction.
There were 31 men and 13 women with a mean age of 35 years (18 to
68) and a mean follow-up of 12 months (6 to 40). No tibial osteotomies
or bone graft procedures were performed. Bony union was achieved
after the initial surgery in 41 (89.1%) tibias. Four persistent
nonunions united after repeat treatment with closed hexapod distraction,
resulting in bony union in 45 (97.8%) patients. The mean time to
union was 23 weeks (11 to 49). Leg-length was restored to within
1 cm of the contralateral side in all tibias. Mechanical alignment
was restored to within 5° of normal in 42 (91.3%) tibias. Closed
distraction of stiff tibial nonunions can predictably lead to union
without further surgery or bone graft. In addition to generating
the required distraction to achieve union, hexapod circular external
fixators can accurately correct concurrent deformities and limb-length
discrepancies. Cite this article:
Back pain is a common symptom in children and
adolescents. Here we review the important causes, of which defects
and stress reactions of the pars interarticularis are the most common
identifiable problems. More serious pathology, including malignancy
and infection, needs to be excluded when there is associated systemic
illness. Clinical evaluation and management may be difficult and
always requires a thorough history and physical examination. Diagnostic
imaging is obtained when symptoms are persistent or severe. Imaging
is used to reassure the patient, relatives and carers, and to guide
management. Cite this article: