Forward DP Ollivere BJ Ng JWG Coughlin TA Rollins KE

Rib fracture fixation by orthopaedic and cardiothoracic surgeons has become increasingly popular for the treatment of chest injuries in trauma. The literature, though mainly limited to Level II and III evidence, shows favourable results for operative fixation. In this paper we review the literature and discuss the indications for rib fracture fixation, surgical approaches, choice of implants and the future direction for management. With the advent of NICE guidance and new British Orthopaedic Association Standards for Trauma (BOAST) guidelines in production, the management of rib fractures is going to become more and more commonplace.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1208 - 1214
1 Sep 2016
Cowling PD Akhtar MA Liow RYL

Objectives

A variety of operative techniques have been described as under the term ‘Bristow-Latarjet’ procedure. This review aims to define the original procedure, and compare the variation in techniques described in the literature, assessing any effect on clinical outcomes.

Materials and Methods

A systematic review of 24 studies was performed to compare specific steps of the technique (coracoid osteotomy site, subscapularis approach, orientation and position of coracoid graft fixation and fixation method, additional labral and capsular repair) and detect any effect this variability had on outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1069 - 1073
1 Aug 2009
Hamid N Loeffler BJ Braddy W Kellam JF Cohen BE Bosse MJ

The purpose of this study was to compare the clinical and radiological outcome of patients with intact, broken and removed syndesmosis screws after Weber B or C ankle fracture with an associated injury to the syndesmosis. We hypothesised that there would be no difference. Of a possible 142 patients who fulfilled our inclusion criteria, 52 returned for clinical and radiological assessment at least one year after surgery. Of these, 27 had intact syndesmosis screws, ten had broken screws, and 15 had undergone elective removal of the screw. The mean American Orthopaedic Foot and Ankle Society ankle/hindfoot score was 83.07 (sd 13.59) in the intact screw group, 92.40 (sd 12.69) in the broken screw group, and 85.80 (sd 11.33) in the removed screw group (p = 0.0466).

There was no difference in clinical outcome of patients with intact or removed syndesmotic screws. Paradoxically, patients with a broken syndesmosis screw had the best clinical outcome. Our data do not support the removal of intact or broken syndesmosis screws, and we caution against attributing post-operative ankle pain to breakage of the syndesmosis screw.


Bone & Joint Research
Vol. 5, Issue 2 | Pages 46 - 51
1 Feb 2016
Du J Wu J Wen Z Lin X

Objectives

To employ a simple and fast method to evaluate those patients with neurological deficits and misplaced screws in relatively safe lumbosacral spine, and to determine if it is necessary to undertake revision surgery.

Methods

A total of 316 patients were treated by fixation of lumbar and lumbosacral transpedicle screws at our institution from January 2011 to December 2012. We designed the criteria for post-operative revision scores of pedicle screw malpositioning (PRSPSM) in the lumbosacral canal. We recommend the revision of the misplaced pedicle screw in patients with PRSPSM = 5′ as early as possible. However, patients with PRSPSM < 5′ need to follow the next consecutive assessment procedures. A total of 15 patients were included according to at least three-stage follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 78 - 84
1 Jan 2011
Putnis SE Pearce R Wali UJ Bircher MD Rickman MS

The aim of this study was to review the number of patients operated on for traumatic disruption of the pubic symphysis who developed radiological signs of movement of the anterior pelvic metalwork during the first post-operative year, and to determine whether this had clinical implications. A consecutive series of 49 patients undergoing internal fixation of a traumatic diastasis of the pubic symphysis were studied. All underwent anterior fixation of the diastasis, which was frequently combined with posterior pelvic fixation. The fractures were divided into groups using the Young and Burgess classification for pelvic ring fractures. The different combinations of anterior and posterior fixation adopted to stabilise the fractures and the type of movement of the metalwork which was observed were analysed and related to functional outcome during the first post-operative year.

In 15 patients the radiographs showed movement of the anterior metalwork, with broken or mobile screws or plates, and in six there were signs of a recurrent diastasis. In this group, four patients required revision surgery; three with anterior fixation and one with removal of anterior pelvic metalwork; the remaining 11 functioned as well as the rest of the study group.

We conclude that radiological signs of movement in the anterior pelvic metalwork, albeit common, are not in themselves an indication for revision surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 270 - 275
1 Feb 2012
Ilharreborde B Gaumetou E Souchet P Fitoussi F Presedo A Penneçot GF Mazda K

Percutaneous epiphysiodesis using transphyseal screws (PETS) has been developed for the treatment of lower limb discrepancies with the aim of replacing traditional open procedures. The goal of this study was to evaluate its efficacy and safety at skeletal maturity. A total of 45 consecutive patients with a mean skeletal age of 12.7 years (8.5 to 15) were included and followed until maturity. The mean efficacy of the femoral epiphysiodesis was 35% (14% to 87%) at six months and 66% (21% to 100%) at maturity. The mean efficacy of the tibial epiphysiodesis was 46% (18% to 73%) at six months and 66% (25% to 100%) at maturity. In both groups of patients the under-correction was significantly reduced between six months post-operatively and skeletal maturity. The overall rate of revision was 18% (eight patients), and seven of these revisions (87.5%) involved the tibia. This series showed that use of the PETS technique in the femur was safe, but that its use in the tibia was associated with a significant rate of complications, including a valgus deformity in nine patients (20%), leading us to abandon it in the tibia. The arrest of growth was delayed and the final loss of growth at maturity was only 66% of that predicted pre-operatively. This should be taken into account in the pre-operative planning.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 73 - 77
1 Nov 2014
Brown NM Hellman M Haughom BH Shah RP Sporer SM Paprosky WG

A pelvic discontinuity occurs when the superior and inferior parts of the hemi-pelvis are no longer connected, which is difficult to manage when associated with a failed total hip replacement. Chronic pelvic discontinuity is found in 0.9% to 2.1% of hip revision cases with risk factors including severe pelvic bone loss, female gender, prior pelvic radiation and rheumatoid arthritis. Common treatment options include: pelvic plating with allograft, cage reconstruction, custom triflange implants, and porous tantalum implants with modular augments. The optimal technique is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable healing between the two segments. A method of treating pelvic discontinuity using porous tantalum components with a distraction technique that achieves both initial stability and subsequent long-term biological fixation is described.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):73–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model.

A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads.

All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (sd 1500), 28 800 cycles (sd 6300), and 26 400 cycles (sd 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (sd 10 700), 36 000 cycles (sd 7200), and 36 600 cycles (sd 10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution.

In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 111 - 117
1 Jun 2012
von Recum J Matschke S Jupiter JB Ring D Souer J Huber M Audigé L

Objectives

To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type.

Methods

A total of 136 patients who received either a 2.4 mm (n = 61) or 3.5 mm (n = 75) distal radius locking compression plate (LCP DR) using a volar approach were followed over two years. The main outcome measurements included motion, grip strength, pain, and the scores of Gartland and Werley, the Short-Form 36 (SF-36) and the Disabilities of the Arm, Shoulder, and Hand (DASH). Differences between the treatment groups were evaluated using regression analysis and the likelihood ratio test with significance based on the Bonferroni corrected p-value of < 0.003.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 73 - 77
1 Jan 2011
Altaf F Osei NA Garrido E Al-Mukhtar M Natali C Sivaraman A Noordeen HH

We describe the results of a prospective case series of patients with spondylolysis, evaluating a technique of direct stabilisation of the pars interarticularis with a construct that consists of a pair of pedicle screws connected by a U-shaped modular link passing beneath the spinous process. Tightening the link to the screws compresses bone graft in the defect in the pars, providing rigid intrasegmental fixation. We have carried out this procedure on 20 patients aged between nine and 21 years with a defect of the pars at L5, confirmed on CT. The mean age of the patients was 13.9 years (9 to 21). They had a grade I or less spondylolisthesis and no evidence of intervertebral degeneration on MRI. The mean follow-up was four years (2.3 to 7.3). The patients were assessed by the Oswestry Disability Index (ODI) and a visual analogue scale (VAS). At the latest follow-up, 18 patients had an excellent clinical outcome, with a significant (p < 0.001) improvement in their ODI and VAS scores. The mean ODI score at final follow-up was 8%. Assessment of the defect by CT showed a rate of union of 80%. There were no complications involving the internal fixation.

The strength of the construct removes the need for post-operative immobilisation.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1436 - 1440
1 Nov 2014
Henderson ER O’Connor MI Ruggieri P Windhager R Funovics PT Gibbons CL Guo W Hornicek FJ Temple HT Letson GD

Previous classification systems of failure of limb salvage focused primarily on endoprosthetic failures and lacked sufficient depth for the effective study of the causes of failure. In order to address these inadequacies, the International Society of Limb Salvage (ISOLS) formed a committee to recommend revisions of the previous systems. The purpose of this study was to report on their recommendations. The modifications were prepared using an earlier, evidence-based model with subclassification based on the existing medical literature. Subclassification for all five primary types of failure of limb salvage following endoprosthetic reconstruction were formulated and a complementary system was derived for the failure of biological reconstruction. An additional classification of failure in paediatric patients was also described.

Limb salvage surgery presents a complex array of potential mechanisms of failure, and a complete and precise classification of types of failure is required. Earlier classification systems lacked specificity, and the evidence-based system outlined here is designed to correct these weaknesses and to provide a means of reporting failures of limb salvage in order to allow the interpretation of outcome following reconstructive surgery.

Cite this article: Bone Joint J 2014;96-B:1436–40.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1699 - 1705
1 Dec 2014
Boyle MJ Gao R Frampton CMA Coleman B

Our aim was to compare the one-year post-operative outcomes following retention or removal of syndesmotic screws in adult patients with a fracture of the ankle that was treated surgically. A total of 51 patients (35 males, 16 females), with a mean age of 33.5 years (16 to 62), undergoing fibular osteosynthesis and syndesmotic screw fixation, were randomly allocated to retention of the syndesmotic screw or removal at three months post-operatively. The two groups were comparable at baseline.

One year post-operatively, there was no significant difference in the mean Olerud–Molander ankle score (82.4 retention vs 86.7 removal, p = 0.367), the mean American Orthopedic Foot and Ankle Society ankle-hindfoot score (88.6 vs 90.1, p = 0.688), the mean American Academy of Orthopedic Surgeons foot and ankle score (96.3 vs 94.0, p = 0.250), the mean visual analogue pain score (1.0 vs 0.7, p = 0.237), the mean active dorsiflexion (10.2° vs 13.0°, p = 0.194) and plantar flexion (33.6° vs 31.3°, p = 0.503) of the ankle, or the mean radiological tibiofibular clear space (5.0 mm vs 5.3 mm, p = 0.276) between the two groups. A total of 19 patients (76%) in the retention group had a loose and/or broken screw one year post-operatively.

We conclude that removal of a syndesmotic screw produces no significant functional, clinical or radiological benefit in adult patients who are treated surgically for a fracture of the ankle.

Cite this article: Bone Joint J 2014;96-B:1699–1705.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 109 - 113
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Pelvic discontinuity represents a rare but challenging problem for orthopaedic surgeons. It is most commonly encountered during revision total hip replacement, but can also result from an iatrogentic acetabular fracture during hip replacement. The general principles in management of pelvic discontinuity include restoration of the continuity between the ilium and the ischium, typically with some form of plating. Bone grafting is frequently required to restore pelvic bone stock. The acetabular component is then impacted, typically using an uncemented, trabecular metal component. Fixation with multiple supplemental screws is performed. For larger defects, a so-called ‘cup–cage’ reconstruction, or a custom triflange implant may be required. Pre-operative CT scanning can greatly assist in planning and evaluating the remaining bone stock available for bony ingrowth. Generally, good results have been reported for constructs that restore stability to the pelvis and allow some form of biologic ingrowth.

Cite this article: Bone Joint J 2013;95-B, Supple A:109–13.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 289 - 296
1 Nov 2012
Savaridas T Wallace RJ Muir AY Salter DM Simpson AHRW

Objectives

Small animal models of fracture repair primarily investigate indirect fracture healing via external callus formation. We present the first described rat model of direct fracture healing.

Methods

A rat tibial osteotomy was created and fixed with compression plating similar to that used in patients. The procedure was evaluated in 15 cadaver rats and then in vivo in ten Sprague-Dawley rats. Controls had osteotomies stabilised with a uniaxial external fixator that used the same surgical approach and relied on the same number and diameter of screw holes in bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm3) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations.

In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1061 - 1065
1 Aug 2010
Cho W Cho SK Wu C

There are three basic concepts that are important to the biomechanics of pedicle screw-based instrumentation. First, the outer diameter of the screw determines pullout strength, while the inner diameter determines fatigue strength. Secondly, when inserting a pedicle screw, the dorsal cortex of the spine should not be violated and the screws on each side should converge and be of good length. Thirdly, fixation can be augmented in cases of severe osteoporosis or revision.

A trajectory parallel or caudal to the superior endplate can minimise breakage of the screw from repeated axial loading. Straight insertion of the pedicle screw in the mid-sagittal plane provides the strongest stability.

Rotational stability can be improved by adding transverse connectors. The indications for their use include anterior column instability, and the correction of rotational deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups.

The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 12 - 18
1 Jan 2011
Eastwood DM Sanghrajka AP

Guiding growth by harnessing the ability of growing bone to undergo plastic deformation is one of the oldest orthopaedic principles. Correction of deformity remains a major part of the workload for paediatric orthopaedic surgeons and recently, along with developments in limb reconstruction and computer-directed frame correction, there has been renewed interest in surgical methods of physeal manipulation or ‘guided growth’. Manipulating natural bone growth to correct a deformity is appealing, as it allows gradual correction by non- or minimally invasive methods.

This paper reviews the techniques employed for guided growth in current orthopaedic practice, including the basic science and recent advances underlying mechanical physeal manipulation of both healthy and pathological physes.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1206 - 1209
1 Sep 2007
Moonot P Ashwood N Hamlet M

Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population.

This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 527 - 534
1 Apr 2010
Streubel PN Gardner MJ Morshed S Collinge CA Gallagher B Ricci WM

It is unclear whether there is a limit to the amount of distal bone required to support fixation of supracondylar periprosthetic femoral fractures. This retrospective multicentre study evaluated lateral locked plating of periprosthetic supracondylar femoral fractures and compared the results according to extension of the fracture distal with the proximal border of the femoral prosthetic component.

Between 1999 and 2008, 89 patients underwent lateral locked plating of a supracondylar periprosthetic femoral fracture, of whom 61 patients with a mean age of 72 years (42 to 96) comprising 53 women, were available after a minimum follow-up of six months or until fracture healing. Patients were grouped into those with fractures located proximally (28) and those with fractures that extended distal to the proximal border of the femoral component (33).

Delayed healing and nonunion occurred respectively in five (18%) and three (11%) of more proximal fractures, and in two (6%) and five (15%) of the fractures with distal extension (p = 0.23 for delayed healing; p = 0.72 for nonunion, Fisher’s exact test). Four construct failures (14%) occurred in more proximal fractures, and three (9%) in fractures with distal extension (p = 0.51). Of the two deep infections that occurred in each group, one resolved after surgical debridement and antibiotics, and one progressed to a nonunion.

Extreme distal periprosthetic supracondylar fractures of the femur are not a contra-indication to lateral locked plating. These fractures can be managed with internal fixation, with predictable results, similar to those seen in more proximal fractures.