Aims. Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated
Aims. The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum
Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%),
Aims. The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. Methods. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision. Results. A total of 514 TEAs were included, of which 35 were revised. The
Aims. Brace treatment is the cornerstone of managing developmental dysplasia of the hip (DDH), yet there is a lack of evidence-based treatment protocols, which results in wide variations in practice. To resolve this, we have developed a comprehensive nonoperative treatment protocol conforming to published consensus principles, with well-defined a priori criteria for inclusion and successful treatment. Methods. This was a single-centre, prospective, longitudinal cohort study of a consecutive series of infants with ultrasound-confirmed DDH who underwent a comprehensive nonoperative brace management protocol in a unified multidisciplinary clinic between January 2012 and December 2016 with
Aims. Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial. Methods. The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival. Results. A total of 407 patients who underwent UKA were included in the study. The mean age of patients was 61.8 years, and the mean follow-up period of the patients was 91.7 months. The mean Knee Society Score (KSS) preoperatively and at the last follow-up were 64.2 and 89.7, respectively (p = 0.001). Overall, 28 patients (6.9%) with UKA underwent revision due to prosthesis loosening (16 patients), dislocation (eight patients), and persistent pain (four patients). Cox proportional hazards model analysis identified malposition of the prostheses as a high-risk factor for UKA failure (p = 0.007). Kaplan-Meier analysis revealed that the
Aims. The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. Methods. A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis. Results. Of 170 patients, 22 (13%) subsequently received a THA. Native hip survival in patients with a step-off ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at
Aims. Varus-valgus constrained (VVC) devices are typically used in revision settings, often with stems to mitigate the risk of aseptic loosening. However, in at least one system, the VVC insert is compatible with the primary posterior-stabilized (PS) femoral component, which may be an option in complex primary situations. We sought to determine the implant survivorship, radiological and clinical outcomes, and complications when this VVC insert was coupled with a PS femur without stems in complex primary total knee arthroplasties (TKAs). Methods. Through our institution’s total joint registry, we identified 113 primary TKAs (103 patients) performed between 2007 and 2017 in which a VVC insert was coupled with a standard cemented PS femur without stems. Mean age was 68 years (SD 10), mean BMI was 32 kg/m. 2. (SD 7), and 59 patients (50%) were male. Mean follow-up was four years (2 to 10). Results. The
Aims. The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes. Methods. We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m. 2. (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2). Results. Three liners (1.2%) were malseated, including two MDMs (1.4%) and one G7 (0.9%). No clinical consequence was identified from malseating. The
Aims. One-stage exchange for periprosthetic joint infection (PJI) in total hip arthroplasty (THA) is gaining popularity. The outcome for a repeat one-stage revision THA after a failed one-stage exchange for infection remains unknown. The aim of this study was to report the infection-free and all-cause revision-free survival of repeat one-stage exchange, and to investigate the association between the Musculoskeletal Infection Society (MSIS) staging system and further infection-related failure. Methods. We retrospectively reviewed all repeat one-stage revision THAs performed after failed one-stage exchange THA for infection between January 2008 and December 2016. The final cohort included 32 patients. The mean follow-up after repeat one-stage exchange was 5.3 years (1.2 to 13.0). The patients with a further infection-related failure and/or all-cause revision were reported, and Kaplan-Meier survival for these endpoints determined. Patients were categorized according to the MSIS system, and its association with further infection was analyzed. Results. A total of eight repeat septic revisions (25%) developed a further infection-related failure, and the
In two centres in Korea 350 patients with a diagnosis of tuberculosis of the thoracic and/or lumbar spine were allocated at random: in Masan to in-patient rest in bed (IP) for six months followed by out-patient treatment or to ambulatory out-patient treatment (OP) from the start; in Pusan to out-patient treatment with a plaster-of-Paris jacket (J) for nine months or to ambulatory treatment without any support (No J). All patients recieved chemotherapy with PAS with isoniazid for eighteen months, either supplemented with streptomycin for the first three months (SPH) or without this supplement (PH), by random allocation. The main analysis of this report concerns 299 patients (eighty-three IP, eighty-three OP, sixty-three J, seventy No J; 143 SPH, 156 PH). Pre-treatment factors were similar in both centres except that the patients in Pusan had, on average, less extensive lesions although in a greater proportion the disease was radiographically active. One patient (J/SPH) died with active spinal disease and three (all No J/SPH) with paraplegia. A fifth patient (IP/PH) who died from cardio respiratory failure also had pulmonary tuberculosis. Twenty-three patients required operation and/or additional chemotherapy for the spinal lesion. A sinus or clinically evident abscess was either present initially or developed during treatment in 41 per cent of patients. Residual lesions persisted in ten patients (four IP, two OP, one J, three No J; six SPH, four PH) at five years. Thirty-two patients had paraparesis on admission or developing later. Complete resolution occurred in twenty on the allocated regimen and in eight after operation or additional chemotherapy or both. Of the remaining four atients, all of whom had operation and additional chemotherapy, three died and one still had paraparesis at five years. Of 295 patients assessed at five years 89 per cent had a favourable status. The proportions of the patients responding favourably were similar in the IP (91 per cent) and OP (89 per cent) series, in the J (90 per cent) and No J (84 per cent) series and in the SPH (86 per cent) and PH (92 per cent) series.
Aims. This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years. Methods. We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up. Results. A total of 86 patients were evaluated at a mean follow-up of 65.4 months (60 to 90). At
Aims. Endoprosthetic reconstruction with a distal femoral arthroplasty (DFA) can be used to treat distal femoral bone loss from oncological and non-oncological causes. This study reports the short-term implant survivorship, complications, and risk factors for patients who underwent DFA for non-neoplastic indications. Methods. We performed a retrospective review of 75 patients from a single institution who underwent DFA for non-neoplastic indications, including aseptic loosening or mechanical failure of a previous prosthesis (n = 25), periprosthetic joint infection (PJI) (n = 23), and native or periprosthetic distal femur fracture or nonunion (n = 27). Patients with less than 24 months’ follow-up were excluded. We collected patient demographic data, complications, and reoperations. Reoperation for implant failure was used to calculate implant survivorship. Results. Overall one- and
Aims. Periprosthetic joint infection (PJI) occurs in approximately 1% to 2% of total knee arthroplasties (TKA) presenting multiple challenges, such as difficulty in diagnosis, technical complexity, and financial costs. Two-stage exchange is the gold standard for treating PJI but emerging evidence suggests 'two-in-one' single-stage revision as an alternative, delivering comparable outcomes, reduced morbidity, and cost-effectiveness. This study investigates
Aims. To assess the correlation between the histological response to preoperative chemotherapy and event-free survival (EFS) or overall survival (OS) in patients with high-grade localized osteosarcoma. Methods. Out of 625 patients aged ≤ 40 years treated for primary high-grade osteosarcoma between 1997 and 2016, 232 patients without clinically detectable metastases at the time of diagnosis and treated with preoperative high-dose methotrexate, adriamycin and cisplatin (MAP) chemotherapy and surgery were included. Associations of chemotherapy-induced necrosis in the resected specimen and EFS or OS were assessed using Cox model and the Pearson’s correlation coefficients (r). Time-dependent receiver operating characteristic analysis was applied to determine the optimal cut-off value of chemotherapy-induced necrosis for EFS and OS. Results. OS was 74% (95% confidence interval (CI) 67 to 79) at five years. Median chemotherapy-induced necrosis was 85% (interquartile range (IQR) 50% to 97%). In multivariate Cox model, chemotherapy-induced necrosis was significantly associated with EFS and OS (hazard ratio (HR) = 0.99 (95% CI 0.98 to 0.99); p < 0.001 and HR = 0.98 (95% CI 0.97 to 0.99); p < 0.001, respectively). Positive correlation was observed between chemotherapy-induced necrosis and
The August 2024 Shoulder & Elbow Roundup. 360. looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated
The October 2023 Trauma Roundup. 360. looks at: Intramedullary nailing versus sliding hip screw in trochanteric fracture management: the INSITE randomized clinical trial;
Aims. The outcome of repeat septic revision after a failed one-stage exchange for periprosthetic joint infection (PJI) in total knee arthroplasty (TKA) remains unknown. The aim of this study was to report the infection-free and all-cause revision-free survival of repeat septic revision after a failed one-stage exchange, and to determine whether the Musculoskeletal Infection Society (MSIS) stage is associated with subsequent infection-related failure. Methods. We retrospectively reviewed all repeat septic revision TKAs which were undertaken after a failed one-stage exchange between 2004 and 2017. A total of 33 repeat septic revisions (29 one-stage and four two-stage) met the inclusion criteria. The mean follow-up from repeat septic revision was 68.2 months (8.0 months to 16.1 years). The proportion of patients who had a subsequent infection-related failure and all-cause revision was reported and Kaplan-Meier survival for these endpoints was determined. Patients were categorized according to the MSIS staging system, and the association with subsequent infection was analyzed. Results. At the most recent follow-up, 17 repeat septic revisions (52%) had a subsequent infection-related failure and the
The October 2024 Children’s orthopaedics Roundup. 360. looks at: Cost-effectiveness analysis of soft bandage and immediate discharge versus rigid immobilization in children with distal radius torus fractures: the FORCE trial; Percutaneous Achilles tendon tenotomy in clubfoot with a blade or a needle: a single-centre randomized controlled noninferiority trial; Treatment of hip displacement in children with cerebral palsy: a