Normal sagittal spine-pelvis-lower extremity alignment is crucial in humans for maintaining an ergonomic upright standing posture, and pathogenesis in any segment leads to poor balance. The present study aimed to investigate how this sagittal alignment can be affected by severe knee osteoarthritis (KOA), and whether associated changes corresponded with symptoms of lower back pain (LBP) in this patient population. Lateral radiograph films in an upright standing position were obtained from 59 patients with severe KOA and 58 asymptomatic controls free from KOA. Sagittal alignment of the spine, pelvis, hip and proximal femur was quantified by measuring several radiographic parameters. Global balance was accessed according to the relative position of the C7 plumb line to the sacrum and femoral heads. The presence of chronic LBP was documented. Comparisons between the two groups were carried by independent samples Objectives
Methods
In arthritis of the varus knee, a high tibial
osteotomy (HTO) redistributes load from the diseased medial compartment
to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women)
with 42 varus, arthritic knees who underwent HTO and dynamic correction
using a Garches external fixator until they felt that normal alignment
had been restored. The mean age of the patients was 54.11 years
(34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3
to 10) post-operatively. Radiographs, gait analysis and visual analogue
scores for pain were measured pre- and post-operatively, at one
year and at medium-term follow-up (mean six years; 2 to 10). Failure
was defined as conversion to knee arthroplasty. Pre-operative gait analysis divided the 42 knees into two equal
groups with high (17 patients) or low (19 patients) adductor moments.
After correction, a statistically significant (p <
0.001, At final follow-up, after a mean of 15.9 years (12 to 20), there
was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of
adductor moment group, with a mean time to conversion to knee arthroplasty
of 9.5 years (3 to 18; 95% confidence interval ± 2.5). HTO remains a useful option in the medium-term for the treatment
of medial compartment osteoarthritis of the knee but does not last
in the long-term. Cite this article:
In our department we use an enhanced recovery
protocol for joint replacement of the lower limb. This incorporates the
use of intravenous tranexamic acid (IVTA; 15 mg/kg) at the induction
of anaesthesia. Recently there was a national shortage of IVTA for
18 weeks; during this period all patients received an oral preparation
of tranexamic acid (OTA; 25 mg/kg). This retrospective study compares
the safety (surgical and medical complications) and efficacy (reduction
of transfusion requirements) of OTA and IVTA. During the study period
a total of 2698 patients received IVTA and 302 received OTA. After
adjusting for a range of patient and surgical factors, the odds
ratio (OR) of receiving a blood transfusion was significantly higher
with IVTA than with OTA (OR 0.48 (95% confidence interval 0.26 to
0.89), p = 0.019), whereas the safety profile was similar, based
on length of stay, rate of readmission, return to theatre, deep
infection, stroke, gastrointestinal bleeding, myocardial infarction,
pneumonia, deep-vein thrombosis and pulmonary embolism. The financial
benefit of OTA is £2.04 for a 70 kg patient; this is amplified when
the cost saving associated with significantly fewer blood transfusions
is considered. Although the number of patients in the study is modest, this
work supports the use of OTA, and we recommend that a randomised
trial be undertaken to compare the different methods of administering
tranexamic acid. Cite this article:
During open orthopaedic surgery, joints may be exposed to air, potentially leading to cartilage drying and chondrocyte death, however, the long-term effects of joint drying The patellar groove of anaesthetised rats was exposed (sham-operated), or exposed and then subjected to laminar airflow (0.25m/s; 60 minutes) before wounds were sutured and animals recovered. Animals were monitored for up to eight weeks and then sacrificed. Cartilage and chondrocyte properties were studied by histology and confocal microscopy, respectively.Objectives
Methods
An extensive review of the spinal and arthroplasty
literature was undertaken to evaluate the effectiveness of local
antibiotic irrigation during surgery. The efficacy of antibiotic
irrigation for the prevention of acute post-operative infection
after total joint arthroplasty was evaluated retrospectively in
2293 arthroplasties (1990 patients) between January 2004 and December
2013. The mean follow-up was 73 months (20 to 139). One surgeon
performed all the procedures with minimal post-operative infection. The intra-operative protocol included an irrigation solution
of normal saline with vancomycin 1000 mg/l and polymyxin 250 000
units/l at the rate of 2 l per hour. No patient required re-admission
for primary infection or further antibiotic treatment. Two morbidly obese
patients (two total hip arthroplasties) developed subcutaneous fat
necrosis requiring debridement and one was revised because the deep
capsular sutures were contaminated by the draining subcutaneous
haematoma. One patient who had undergone total knee arthroplasty
had unrecognised damage to the lateral superior geniculate artery
and developed a haematoma that became infected secondarily four
months after the surgery and underwent revision. The use of antibiotic irrigation during arthroplasty surgery
has been highly effective for the prevention of infection in the
author’s practice. However, it should be understood that any routine
prophylactic use of antibiotics may result in resistant organisms,
and the wise stewardship of the use of antibiotics is an important
part of surgical practice. Cite this article:
The purpose of this article is to provide the
reader with a seven-step checklist that could help in minimising
the risk of PJI. The check list includes strategies that can be
implemented pre-operatively such as medical optimisation, and reduction
of the bioburden by effective skin preparation or actions taking
during surgery such as administration of timely and appropriate
antibiotics or blood conservation, and finally implementation of
post-operative protocols such as efforts to minimise wound drainage
and haematoma formation. Cite this article:
The December 2015 Spine Roundup360 looks at: Ketamine in scoliosis surgery; Teriparatide in osteoporotic spinal fractures; Trabecular metal in the spine?; Revision surgery a SPORTing chance?; The course of degenerative lumbar spondylolisthesis; Hip or lumbar spine: a common conundrum
The December 2015 Research Roundup360 looks at: Biomarkers in periprosthetic joint infection; HbA1c and complications in arthroplasty; Getting to the bottom of biofilms; Effective antibiosis for biofilms; Stem cells and avascular necrosis; Predicting LOS in total joint arthroplasty; Long-term antibiotics reduce recurrence in periprosthetic infection
Sagittal alignment of the lumbosacral spine, and specifically pelvic incidence (PI), has been implicated in the development of spine pathology, but generally ignored with regards to diseases of the hip. We aimed to determine if increased PI is correlated with higher rates of hip osteoarthritis (HOA). The effect of PI on the development of knee osteoarthritis (KOA) was used as a negative control. We studied 400 well-preserved cadaveric skeletons ranging from 50 to 79 years of age at death. Each specimen’s OA of the hip and knee were graded using a previously described method. PI was measured from standardised lateral photographs of reconstructed pelvises. Multiple regression analysis was performed to determine the relationship between age and PI with HOA and KOA.Objectives
Methods
To review the current best surgical practice and detail a multi-disciplinary
approach that could further reduce joint replacement infection. Review of relevant literature indexed in PubMed.Objectives
Methods
We describe our technique and rationale using
hybrid fixation for primary total hip arthroplasty (THA) at the Hospital
for Special Surgery. Modern uncemented acetabular components have
few screw holes, or no holes, polished inner surfaces, improved
locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented
sockets can be combined with highly cross-linked polyethylene liners,
which have demonstrated very low wear and osteolysis rates after
ten to 15 years of implantation. The results of cement fixation
with a smooth or polished surface finished stem have been excellent,
virtually eliminating complications seen with cementless fixation
like peri-operative femoral fractures and thigh pain. Although mid-term
results of modern cementless stems are encouraging, the long-term
data do not show reduced revision rates for cementless stems compared
with cemented smooth stems. In this paper we review the conduct
of a hybrid THA, with emphasis on pre-operative planning, surgical
technique, hypotensive epidural anaesthesia, and intra-operative
physiology. Cite this article:
A retrospective review was performed of patients
undergoing primary cementless total knee replacement (TKR) using
porous tantalum performed by a group of surgical trainees. Clinical
and radiological follow-up involved 79 females and 26 males encompassing
115 knees. The mean age was 66.9 years (36 to 85). Mean follow-up
was 7 years (2 to 11). Tibial and patellar components were porous
tantalum monoblock implants, and femoral components were posterior
stabilised (PS) in design with cobalt–chromium fibre mesh. Radiological
assessments were made for implant positioning, alignment, radiolucencies,
lysis, and loosening. There was 95.7% survival of implants. There
was no radiological evidence of loosening and no osteolysis found.
No revisions were performed for aseptic loosening. Average tibial
component alignment was 1.4° of varus (4°of valgus to 9° varus),
and 6.2° (3° anterior to 15° posterior) of posterior slope. Mean
femoral component alignment was 6.6° (1° to 11°) of valgus. Mean tibiofemoral
alignment was 5.6° of valgus (7° varus to 16° valgus). Patellar
tilt was a mean of 2.4° lateral (5° medial to 28° lateral). Patient
satisfaction with improvement in pain was 91%. Cementless TKR incorporating
porous tantalum yielded good clinical and radiological outcomes
at a mean of follow-up of seven-years. Cite this article:
Bactericidal levels of antibiotics are difficult
to achieve in infected total joint arthroplasty when intravenous antibiotics
or antibiotic-loaded cement spacers are used, but intra-articular
(IA) delivery of antibiotics has been effective in several studies.
This paper describes a protocol for IA delivery of antibiotics in
infected knee arthroplasty, and summarises the results of a pharmacokinetic
study and two clinical follow-up studies of especially difficult
groups: methicillin-resistant Cite this article:
Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral shaft were included in this retrospective
study. The mean age was 51.3 years (14 to 88). The patients had
a mean of 1.5 prior operations ( All patients were assessed according to a specific risk score
in order to devise an optimal and individual therapy plan consistent
with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis
to an angular stable locking compression plate was performed. According
to the individual risk an additional bone graft and/or bone morphogenetic
protein-7 (BMP-7) were applied. A successful consolidation of the nonunion was observed in 37
cases (80.4%) with a median healing time of six months (IQR 6).
Younger patients showed significantly better consolidation. Four
patients were lost to follow-up. Revision was necessary in a total
of eight (16%) cases. In the initial treatment, intramedullary nailing
was most common. Methods
Results
Total knee replacement (TKR) is an effective
method of treating end-stage arthritis of the knee. It is not, however,
a procedure without risk due to a number of factors, one of which
is diabetes mellitus. The purpose of this study was to estimate
the general prevalence of diabetes in patients about to undergo
primary TKR and to determine whether diabetes mellitus adversely
affects the outcome. We conducted a systematic review and meta-analysis
according to the Meta-analysis Of Observational Studies in Epidemiology
(MOOSE) guidelines. The Odds Ratio (OR) and mean difference (MD)
were used to represent the estimate of risk of a specific outcome.
Our results showed the prevalence of diabetes mellitus among patients
undergoing TKR was 12.2%. Patients with diabetes mellitus had an increased
risk of deep infection (OR = 1.61, 95% confidence interval (CI),
1.38 to 1.88), deep vein thrombosis (in Asia, OR = 2.57, 95% CI,
1.58 to 4.20), periprosthetic fracture (OR = 1.89, 95% CI, 1.04
to 3.45), aseptic loosening (OR = 9.36, 95% CI, 4.63 to 18.90),
and a poorer Knee Society function subscore (MD = -5.86, 95% CI,
-10.27 to -1.46). Surgeons should advise patients specifically about
these increased risks when obtaining informed consent and be meticulous about
their peri-operative care. Cite this article:
The June 2013 Hip &
Pelvis Roundup360 looks at: failure in metal-on-metal arthroplasty; minimal hip approaches; whether bisphosphonates improve femoral bone stock following arthroplasty; whether more fat means more operative time; surgical infection; vascularised fibular graft for osteonecrosis; subclinical SUFE; and dentists, hips and antibiotics.
In this paper, we consider wound healing after
total knee arthroplasty.
Unicompartmental knee arthroplasty (UKA) has
advantages over total knee arthroplasty but national joint registries report
a significantly higher revision rate for UKA. As a result, most
surgeons are highly selective, offering UKA only to a small proportion
(up to 5%) of patients requiring arthroplasty of the knee, and consequently
performing few each year. However, surgeons with large UKA practices
have the lowest rates of revision. The overall size of the practice
is often beyond the surgeon’s control, therefore case volume may
only be increased by broadening the indications for surgery, and
offering UKA to a greater proportion of patients requiring arthroplasty
of the knee. The aim of this study was to determine the optimal UKA usage
(defined as the percentage of knee arthroplasty practice comprised
by UKA) to minimise the rate of revision in a sample of 41 986 records
from the for National Joint Registry for England and Wales (NJR). UKA usage has a complex, non-linear relationship with the rate
of revision. Acceptable results are achieved with the use of 20%
or more. Optimal results are achieved with usage between 40% and
60%. Surgeons with the lowest usage (up to 5%) have the highest
rates of revision. With optimal usage, using the most commonly used
implant, five-year survival is 96% (95% confidence interval (CI)
94.9 to 96.0), compared with 90% (95% CI 88.4 to 91.6) with low
usage (5%) previously considered ideal. The rate of revision of UKA is highest with low usage, implying
the use of narrow, and perhaps inappropriate, indications. The widespread
use of broad indications, using appropriate implants, would give
patients the advantages of UKA, without the high rate of revision. Cite this article:
In England and Wales more than 175 000 hip and
knee arthroplasties were performed in 2012. There continues to be a
steady increase in the demand for joint arthroplasty because of
population demographics and improving survivorship. Inevitably though
the absolute number of periprosthetic infections will probably increase
with severe consequences on healthcare provision. The Department
of Health and the Health Protection Agency in United Kingdom established
a Surgical Site Infection surveillance service (SSISS) in 1997 to
undertake surveillance of surgical site infections. In 2004 mandatory
reporting was introduced for one quarter of each year. There has
been a wide variation in reporting rates with variable engagement
with the process. The aim of this article is to improve surgeon
awareness of the process and emphasise the importance of engaging
with SSISS to improve the quality and type of data submitted. In
Exeter we have been improving our practice by engaging with SSISS.
Orthopaedic surgeons need to take ownership of the data that are
submitted to ensure these are accurate and comprehensive. Cite this article:
It is probable that both genetic and environmental
factors play some part in the aetiology of most cases of degenerative
hip disease. Geneticists have identified some single gene disorders
of the hip, but have had difficulty in identifying the genetics
of many of the common causes of degenerative hip disease. The heterogeneity
of the phenotypes studied is part of the problem. A detailed classification
of phenotypes is proposed. This study is based on careful documentation
of 2003 consecutive total hip replacements performed by a single
surgeon between 1972 and 2000. The concept that developmental problems
may initiate degenerative hip disease is supported. The influences
of gender, age and body mass index are outlined. Biomechanical explanations
for some of the radiological appearances encountered are suggested.
The body weight lever, which is larger than the abductor lever, causes
the abductor power to be more important than body weight. The possibility
that a deficiency in joint lubrication is a cause of degenerative
hip disease is discussed. Identifying the phenotypes may help geneticists
to identify genes responsible for degenerative hip disease, and
eventually lead to a definitive classification.