Advertisement for orthosearch.org.uk
Results 501 - 520 of 788
Results per page:
Bone & Joint 360
Vol. 5, Issue 5 | Pages 19 - 21
1 Oct 2016


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1455 - 1462
1 Nov 2016
Matharu GS Berryman F Brash L Pynsent PB Dunlop DJ Treacy RBC

Aims

We investigated whether blood metal ion levels could effectively identify patients with bilateral Birmingham Hip Resurfacing (BHR) implants who have adverse reactions to metal debris (ARMD).

Patients and Methods

Metal ion levels in whole blood were measured in 185 patients with bilateral BHRs. Patients were divided into those with ARMD who either had undergone a revision for ARMD or had ARMD on imaging (n = 30), and those without ARMD (n = 155). Receiver operating characteristic analysis was used to determine the optimal thresholds of blood metal ion levels for identifying patients with ARMD.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 34 - 40
1 Oct 2016
Emerson RH Alnachoukati O Barrington J Ennin K

Aims

Approved by the Food and Drug Administration in 2004, the Phase III Oxford Medial Partial Knee is used to treat anteromedial osteoarthritis (AMOA) in patients with an intact anterior cruciate ligament. This unicompartmental knee arthroplasty (UKA) is relatively new in the United States, and therefore long-term American results are lacking.

Patients and Methods

This is a single surgeon, retrospective study based on prospectively collected data, analysing a consecutive series of primary UKAs using the Phase III mobile-bearing Oxford Knee and Phase III instrumentation.

Between July 2004 and December 2006, the senior author (RHE) carried out a medial UKA in 173 patients (213 knees) for anteromedial osteoarthritis or avascular necrosis (AVN).

A total of 95 patients were men and 78 were women. Their mean age at surgery was 67 years (38 to 89) and mean body mass index 29.87 kg/m2 (17 to 62).

The mean follow-up was ten years (4 to 11).


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 41 - 47
1 Oct 2016
Lisowski LA Meijer LI Bekerom MPJVD Pilot P Lisowski AE

Aims

The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs.

Patients and Methods

Between January 1999 and January 2005 a total of 138 consecutive Oxford Phase III arthroplasties were performed by a single surgeon in 129 patients for medial compartment osteoarthritis (71 right and 67 left knees, mean age 72.0 years (47 to 91), mean body mass index 28.2 (20.7 to 52.2)). Both clinical data and radiographs were prospectively recorded and obtained at intervals. Of the 129 patients, 32 patients (32 knees) died, ten patients (12 knees) were not able to take part in the final clinical and radiological assessment due to physical and mental conditions, but via telephone interview it was confirmed that none of these ten patients (12 knees) had a revision of the knee arthroplasty. One patient (two knees) was lost to follow-up.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 12 - 14
1 Feb 2016


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 278 - 281
1 Feb 2016
Švehlík M Steinwender G Lehmann T Kraus T

Aims

Single event multilevel surgery (SEMLS) has been shown to improve gait in children with cerebral palsy (CP). However, there is limited evidence regarding long-term outcomes and factors influencing them.

Methods

In total 39 children (17 females and 22 males; mean age at SEMLS ten years four months, standard deviation 37 months) with bilateral CP (20 Gross Motor Function Classification System (GMFCS) level II and 19 GMFCS level III) treated with SEMLS were included. Children were evaluated using gait analysis and the Gait Deviation Index (GDI) before SEMLS and one, two to three, five and at least ten years after SEMLS. A linear mixed model was used to estimate the effect of age at the surgery, GMFCS and follow-up period on GDI.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 402 - 409
1 Mar 2016
Sudo H Kaneda K Shono Y Iwasaki N

Aims

A total of 30 patients with thoracolumbar/lumbar adolescent idiopathic scoliosis (AIS) treated between 1989 and 2000 with anterior correction and fusion surgery using dual-rod instrumentation were reviewed.

Patients and Methods

Radiographic parameters and clinical outcomes were compared among patients with lowest instrumented vertebra (LIV) at the lower end vertebra (LEV; EV group) (n = 13) and those treated by short fusion (S group), with LIV one level proximal to EV (n = 17 patients).


Bone & Joint 360
Vol. 5, Issue 4 | Pages 20 - 22
1 Aug 2016


Bone & Joint Research
Vol. 5, Issue 6 | Pages 215 - 217
1 Jun 2016
Pijls BG Nelissen RGHH


Bone & Joint 360
Vol. 5, Issue 3 | Pages 17 - 19
1 Jun 2016


Bone & Joint 360
Vol. 4, Issue 5 | Pages 16 - 18
1 Oct 2015

The October 2015 Wrist & Hand Roundup360 looks at: Base of thumb arthritis – steroids not a waste of time; De Quervain’s tenosynovitis and steroids; Use your therapy time wisely!; Excision osteotomy for the carpometacarpal joint?; CORDLESS at five years?; Arthroscopy again of no benefit?; Distal radius stirring up trouble again!; Scaphoid arthroscopy under the spotlight


Bone & Joint Research
Vol. 5, Issue 6 | Pages 225 - 231
1 Jun 2016
Yeung M Kowalczuk M Simunovic N Ayeni OR

Objective

Hip arthroscopy in the setting of hip dysplasia is controversial in the orthopaedic community, as the outcome literature has been variable and inconclusive. We hypothesise that outcomes of hip arthroscopy may be diminished in the setting of hip dysplasia, but outcomes may be acceptable in milder or borderline cases of hip dysplasia.

Methods

A systematic search was performed in duplicate for studies investigating the outcome of hip arthroscopy in the setting of hip dysplasia up to July 2015. Study parameters including sample size, definition of dysplasia, outcomes measures, and re-operation rates were obtained. Furthermore, the levels of evidence of studies were collected and quality assessment was performed.


Aims

To investigate the longevity of uncemented fixation of a femoral component in total hip arthroplasty (THA) in patients with Dorr type C proximal femoral morphology.

Patients and Methods

A total of 350 consecutive uncemented THA in 320 patients were performed between 1983 and 1987, by a single surgeon using the Taperloc femoral component. The 63 patients (68 hips) with Dorr type C proximal femoral morphology were the focus of this review. The mean age of the patients was 69 years (24 to 88) and mean follow-up was 16.6 years (ten to 29). Survival analysis included eight patients (eight hips) who died without undergoing revision surgery prior to obtaining ten years follow-up. All 55 surviving patients (60 hips) were available for clinical assessment and radiographic review. As a comparator group, the survival and implant fixation in the remaining 282 THAs (257 patients) with Dorr type A and B morphology were evaluated. The mean age of these patients was 52 years (20 to 82).


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 634 - 640
1 May 2016
Pedowitz DI Kane JM Smith GM Saffel HL Comer C Raikin SM

Aims

Few reports compare the contribution of the talonavicular articulation to overall range of movement in the sagittal plane after total ankle arthroplasty (TAA) and tibiotalar arthrodesis. The purpose of this study was to assess changes in ROM and functional outcomes following tibiotalar arthrodesis and TAA.

Patients and Methods

Patients who underwent isolated tibiotalar arthrodesis or TAA with greater than two-year follow-up were enrolled in the study. Overall arc of movement and talonavicular movement in the sagittal plane were assessed with weight-bearing lateral maximum dorsiflexion and plantarflexion radiographs. All patients completed Short Form-12 version 2.0 questionnaires, visual analogue scale for pain (VAS) scores, and the Foot and Ankle Ability Measure (FAAM).


Bone & Joint 360
Vol. 5, Issue 2 | Pages 16 - 18
1 Apr 2016


Bone & Joint Research
Vol. 5, Issue 6 | Pages 206 - 214
1 Jun 2016
Malak TT Broomfield JAJ Palmer AJR Hopewell S Carr A Brown C Prieto-Alhambra D Glyn-Jones S

Objectives

High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA).

Methods

We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015.


Bone & Joint 360
Vol. 4, Issue 3 | Pages 25 - 26
1 Jun 2015

The June 2015 Oncology Roundup360 looks at: Infection in megaprosthesis; Impressive results for mid femoral reconstruction; Revered teaching or old myth? Femoral neck protection in metastatic disease; Megaprosthesis about the knee; Malignant transformation in multiple hereditary exostoses; Fracture of intercalary bone allograft; Comorbidity and outcomes in sarcoma; A worrying turn? Use of denosumab for giant cell tumour of bone


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 601 - 607
1 May 2016
McClelland D Barlow D Moores TS Wynn-Jones C Griffiths D Ogrodnik PJ Thomas PBM

In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment.

We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty.

Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up.

At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5).

HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term.

Cite this article: Bone Joint J 2016;98-B:601–7.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 381 - 386
1 Mar 2016
Prasad N Ali A Stanley D

Aims

We review our experience of Coonrad-Morrey total elbow arthroplasty (TEA) for fractures of the distal humerus in non-rheumatoid patients with a minimum of ten years follow-up.

Patients and Methods

TEA through a triceps splitting approach was peformed in 37 non-rheumatoid patients for a fracture of the distal humerus between 1996 and 2004. One patient could not be traced and 17 had died before the tenth anniversary of their surgery. This left 19 patients with a minimum follow-up of ten years to form the study group. Of these, 13 patients were alive at the time of final review. The other six had died, but after the tenth anniversary of their elbow arthroplasty. Their clinical and radiological data were included in the study.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 20 - 21
1 Feb 2016