As residency training programmes around the globe
move towards competency-based medical education (CBME), there is
a need to review current teaching and assessment practices as they
relate to education in orthopaedic trauma. Assessment is the cornerstone
of CBME, as it not only helps to determine when a trainee is fit
to practice independently, but it also provides feedback on performance
and guides the development of competence. Although a standardised
core knowledge base for trauma care has been developed by the leading
national accreditation bodies and international agencies that teach
and perform research in orthopaedic trauma, educators have not yet established
optimal methods for assessing trainees’ performance in managing
orthopaedic trauma patients. This review describes the existing knowledge from the literature
on assessment in orthopaedic trauma and highlights initiatives that
have recently been undertaken towards CBME in the United Kingdom,
Canada and the United States. In order to support a CBME approach, programmes need to improve
the frequency and quality of assessments and improve on current
formative and summative feedback techniques in order to enhance
resident education in orthopaedic trauma. Cite this article:
The primary purpose of this meta-analysis was to determine whether statin usage could reduce the risk of glucocorticoid-related osteonecrosis in animal models. A systematic literature search up to May 2015 was carried out using the PubMed, Ovid, EBM reviews, ISI Web of Science, EBSCO, CBM, CNKI databases with the term and boolean operators: statins and osteonecrosis in all fields. Risk ratio (RR), as the risk estimate of specific outcome, was calculated along with 95% confidence intervals (CI). The methodological quality of individual studies was assessed using a quantitative tool based on the updated Stroke Therapy Academic Industry Roundtable (STAIR) recommendations.Objectives
Methods
We undertook a retrospective study investigating
the accuracy and safety of percutaneous pedicle screws placed under
fluoroscopic guidance in the lumbosacral junction and lumbar spine.
The CT scans of patients were chosen from two centres: European
patients from University Medical Center Hamburg-Eppendorf, Germany,
and Asian patients from the University of Malaya, Malaysia. Screw
perforations were classified into grades 0, 1, 2 and 3. A total
of 880 percutaneous pedicle screws from 203 patients were analysed:
614 screws from 144 European patients and 266 screws from 59 Asian
patients. The mean age of the patients was 58.8 years (16 to 91)
and there were 103 men and 100 women. The total rate of perforation
was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade
3 perforations. The rate of perforation in Europeans was 10.4% and
in Asians was 8.6%, with no significant difference between the two
(p = 0.42). The rate of perforation was the highest in S1 (19.4%)
followed by L5 (14.9%). The accuracy and safety of percutaneous
pedicle screw placement are comparable to those cited in the literature
for the open method of pedicle screw placement. Greater caution
must be taken during the insertion of L5 and S1 percutaneous pedicle
screws owing to their more angulated pedicles, the anatomical variations
in their vertebral bodies and the morphology of the spinal canal
at this location. Cite this article:
Patients with osteoarthritis of the knee commonly have degenerative
meniscal tears. Arthroscopic meniscectomy is frequently performed,
although the benefits are debatable. Recent studies have concluded
that there is no role for arthroscopic washout in osteoarthritis
of the knee. Our aim was to perform a systematic review to assess
the evidence for the efficacy of arthroscopic meniscectomy in patients
with meniscal tears and degenerative changes in the knee. A literature search was performed, using the PubMed/MEDLINE database,
for relevant articles published between 1975 and 2015. A total of
six studies, including five randomised controlled trials and one
cross-sectional study of a prospective cohort, met the inclusion
criteria. Relevant information including study design, operations,
the characteristics of the patients, outcomes, adverse events and
further operations were extracted.Aims
Patients and Methods
Injuries to the limb are the most frequent cause
of permanent disability following combat wounds. We reviewed the medical
records of 450 soldiers to determine the type of upper limb nerve
injuries sustained, the rate of remaining motor and sensory deficits
at final follow-up, and the type of Army disability ratings granted.
Of 189 soldiers with an injury of the upper limb, 70 had nerve-related
trauma. There were 62 men and eight women with a mean age of 25
years (18 to 49). Disabilities due to nerve injuries were associated
with loss of function, neuropathic pain or both. The mean nerve-related
disability was 26% (0% to 70%), accounting for over one-half of
this cohort’s cumulative disability. Patients injured in an explosion
had higher disability ratings than those injured by gunshot. The
ulnar nerve was most commonly injured, but most disability was associated
with radial nerve trauma. In terms of the final outcome, at military
discharge 59 subjects (84%) experienced persistent weakness, 48
(69%) had a persistent sensory deficit and 17 (24%) experienced
chronic pain from scar-related or neuropathic pain. Nerve injury
was the cause of frequent and substantial disability in our cohort
of wounded soldiers. Cite this article:
The purpose of this study was to clarify the appearance of the reparative tissue on the articular surface and to analyse the properties of the reparative tissue after hemicallotasis osteotomy (HCO) using MRI T1ρ and T2 mapping. Coronal T1ρ and T2 mapping and three-dimensional gradient-echo images were obtained from 20 subjects with medial knee osteoarthritis. We set the regions of interest (ROIs) on the full-thickness cartilage of the medial femoral condyle (MFC) and medial tibial plateau (MTP) of the knee and measured the cartilage thickness (mm) and T1ρ and T2 relaxation times (ms). Statistical analysis of time-dependent changes in the cartilage thickness and the T1ρ and T2 relaxation times was performed using one-way analysis of variance, and Scheffe’s test was employed for Objectives
Methods
We report the clinical outcome and findings at
second-look arthroscopy of 216 patients (mean age 25 years (11 to 58))
who underwent anterior cruciate ligament (ACL) reconstruction or
augmentation. There were 73 single-bundle ACL augmentations (44
female, 29 male), 82 double-bundle ACL reconstructions (35 female,
47 male), and 61 single-bundle ACL reconstructions (34 female, 27
male). In 94 of the 216 patients, proprioceptive function of the knee
was evaluated before and 12 months after surgery using the threshold
to detect passive motion test. Second-look arthroscopy showed significantly better synovial
coverage of the graft in the augmentation group (good: 60 (82%),
fair: 10 (14%), poor: 3 (4%)) than in the other groups (p = 0.039).
The mean side-to-side difference measured with a KT-2000 arthrometer
was 0.4 mm (-3.3 to 2.9) in the augmentation group, 0.9 mm (-3.2
to 3.5) in the double-bundle group, and 1.3 mm (-2.7 to 3.9) in
the single-bundle group: the result differed significantly between
the augmentation and single-bundle groups (p = 0 .013). No significant
difference in the Lysholm score or pivot-shift test was seen between
the three groups (p = 0.09 and 0.65, respectively). In patients
with good synovial coverage, three of the four measurements used
revealed significant improvement in proprioceptive function (p = 0.177,
0.020, 0.034, and 0.026). We conclude that ACL augmentation is a reasonable treatment option
for patients with favourable ACL remnants. Cite this article:
Joint replacement of the hip and knee remain
very satisfactory operations. They are, however, expensive. The
actual manufacturing of the implant represents only 30% of the final
cost, while sales and marketing represent 40%. Recently, the patents
on many well established and successful implants have expired. Companies
have started producing and distributing implants that purport to
replicate existing implants with good long-term results. The aims of this paper are to assess the legality, the monitoring
and cost saving implications of such generic implants. We also assess
how this might affect the traditional orthopaedic implant companies. Cite this article:
The purpose of the present study was to examine the long-term
fixation of a cemented fixed-bearing polished titanium tibial baseplate
(Genesis ll). Patients enrolled in a previous two-year prospective trial (n
= 35) were recalled at ten years. Available patients (n = 15) underwent
radiostereometric analysis (RSA) imaging in a supine position using
a conventional RSA protocol. Migration of the tibial component in
all planes was compared between initial and ten-year follow-up.
Outcome scores including the Knee Society Score, Western Ontario
and McMaster Universities Arthritis Index, 12-item Short Form Health
Survey, Forgotten Joint Score, and University of California, Los
Angeles Activity Score were recorded.Aims
Patients and Methods
The aim of this study was to assess the effect
of injecting genetically engineered chondrocytes expressing transforming
growth factor beta 1 (TGF-β1) into the knees of patients with osteoarthritis.
We assessed the resultant function, pain and quality of life. A total of 54 patients (20 men, 34 women) who had a mean age
of 58 years (50 to 66) were blinded and randomised (1:1) to receive
a single injection of the active treatment or a placebo. We assessed
post-treatment function, pain severity, physical function, quality
of life and the incidence of treatment-associated adverse events. Patients
were followed at four, 12 and 24 weeks after injection. At final follow-up the treatment group had a significantly greater
improvement in the mean International Knee Documentation Committee
score than the placebo group (16 points; -18 to 49, This technique may result in improved clinical outcomes, with
the aim of slowing the degenerative process, leading to improvements
in pain and function. However, imaging and direct observational
studies are needed to verify cartilage regeneration. Nevertheless,
this study provided a sufficient basis to proceed to further clinical testing. Cite this article:
The results of the DRAFFT (distal radius acute
fracture fixation trial) study, which compared volar plating with
Kirschner (K-) wire fixation for dorsally displaced fractures of
the distal radius, were published in August 2014. The use of K-wires
to treat these fractures is now increasing, with a concomitant decline
in the use of volar locking plates. We provide a critical appraisal of the DRAFFT study and question
whether surgeons have been unduly influenced by its headline conclusions. Cite this article:
Our aim, using English Hospital Episode Statistics data before
during and after the Distal Radius Acute Fracture Fixation Trial
(DRAFFT), was to assess whether the results of the trial affected
clinical practice. Data were grouped into six month intervals from July 2005 to
December 2014. All patient episodes in the National Health Service
involving emergency surgery for an isolated distal radial fracture
were included.Aims
Patients and Methods
The purpose of the study was to investigate whether closed intramedullary
(IM) nailing with percutaneous cement augmentation is better than
conventional closed nailing at relieving pain and suppressing tumours
in patients with metastases of the femur and humerus. A total of 43 patients (27 men, 16 women, mean age 63.7 years,
standard deviation (Aims
Patients and Methods
The purpose of this study was to analyse the biomechanics of
walking, through the ground reaction forces (GRF) measured, after
first metatarsal osteotomy or metatarsophalangeal joint (MTP) arthrodesis. A total of 19 patients underwent a Scarf osteotomy (50.3 years,
standard deviation (Aims
Patients and Methods
Total wrist arthrodesis (TWA) produces a spectrum of outcomes.
We investigated this by reviewing 77 consecutive TWA performed for
inflammatory and post-traumatic arthropathies, wrist instability
and as a salvage procedure. All operations were performed by a single surgeon using a specifically
designed pre-contoured dorsally applied non-locking wrist arthrodesis
plate at a single centre. Aims
Patients and Methods
Induced membrane technique is a relatively new technique in the reconstruction of large bone defects. It involves the implantation of polymethylmethacrylate (PMMA) cement in the bone defects to induce the formation of membranes after radical debridement and reconstruction of bone defects using an autologous cancellous bone graft in a span of four to eight weeks. The purpose of this study was to explore the clinical outcomes of the induced membrane technique for the treatment of post-traumatic osteomyelitis in 32 patients. A total of 32 cases of post-traumatic osteomyelitis were admitted to our department between August 2011 and October 2012. This retrospective study included 22 men and ten women, with a mean age of 40 years (19 to 70). Within this group there were 20 tibias and 12 femurs with a mean defect of 5 cm (1.5 to 12.5). Antibiotic-loaded PMMA cement was inserted into the defects after radical debridement. After approximately eight weeks, the defects were implanted with bone graft.Objectives
Methods
We report a prospective cohort study of the midterm results of
surgical dislocation of the hip (according to Ganz) to perform resection
of osteochondromas involving the femoral neck in patients with multiple
hereditary exostoses (MHE). Hip range of movement (ROM) was assessed pre- and post-operatively.
Patients’ judgment of post-operative reduction of pain, symptoms,
the Rand 36-item Health Survey (RAND-36) and complications were
analysed. Aims
Methods
Hip fracture is a global public health problem.
The National Hip Fracture Database provides a framework for service evaluation
in this group of patients in the United Kingdom, but does not collect
patient-reported outcome data and is unable to provide meaningful
data about the recovery of quality of life. We report one-year patient-reported outcomes of a prospective
cohort of patients treated at a single major trauma centre in the
United Kingdom who sustained a hip fracture between January 2012
and March 2014. There was an initial marked decline in quality of life from baseline
measured using the EuroQol 5 Dimensions score (EQ-5D). It was followed
by a significant improvement to 120 days for all patients. Although
their quality of life improved during the year after the fracture,
it was still significantly lower than before injury irrespective
of age group or cognitive impairment (mean reduction EQ-5D 0.22;
95% confidence interval (CI) 0.17 to 0.26). There was strong evidence
that quality of life was lower for patients with cognitive impairment.
There was a mean reduction in EQ-5D of 0.28 (95% CI 0.22 to 0.35)
in patients <
80 years of age. This difference was consistent
(and fixed) throughout follow-up. Quality of life does not improve
significantly during recovery from hip fracture in patients over
80 years of age (p = 0.928). Secondary measures of function showed
similar trends. Hip fracture marks a step down in the quality of life of a patient:
it accounts for approximately 0.22 disability adjusted life years
in the first year after fracture. This is equivalent to serious
neurological conditions for which extensive funding for research
and treatment is made available. Cite this article: