Advertisement for orthosearch.org.uk
Results 461 - 480 of 1053
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 240 - 242
1 Mar 1998
Witt JD Kamineni S

We dissected 21 cadaver elbows to determine the relationship of the posterior interosseous nerve to the posterolateral approach to the elbow and head of the radius. At the distal end of the exposure the first branches at risk, those to extensor carpi ulnaris, were on average 6.0 ± 1.0 cm (4.0 to 8.4) from the articular surface of the radial head. When using the posterolateral approach it is important that the interval between extensor carpi ulnaris and anconeus is clearly identified with the forearm fully pronated. The supinator should be released close to its ulnar border. It is safe to expose the proximal radius as far as the distal aspect of the bicipital tuberosity


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 24 - 33
1 Jan 2019
Kayani B Konan S Tahmassebi J Rowan FE Haddad FS

Aims

The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) versus robotic-arm assisted UKA.

Patients and Methods

This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 650 - 652
1 Jul 1997
Buckingham RA Winson IG Kelly AJ

We describe a medial midline portal between the tendons of extensor hallucis longus and tibialis anterior for arthroscopy of the ankle. We dissected 20 cadaver specimens to compare the risk of neurovascular injury using this approach with that of using standard arthroscopic portals. Compared with the anterocentral portal, the medial midline was a mean of 11.2 mm further from the nearest branch of the superficial peroneal nerve and 10.3 mm further from the dorsalis pedis artery. This portal allows good access to the joint surface and intra-articular structures and has a lower risk of injury to the dorsalis pedis artery, deep peroneal nerve or the medial branch of the superficial peroneal nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 381 - 384
1 May 1991
Cohen M Wall E Kerber C Abitbol J Garfin

The nerve roots of the cauda equina may be visualised by contrast-enhanced CT scans and by surface-coil MRI. We have identified the pattern of anatomy from L2-L3 to L5-S1 in 10 human cadaver specimens and correlated this with anatomical dissections. Individual roots are slightly more distinct on contrast-enhanced CT than on surface-coil MRI. There is a crescentic oblique pattern of nerve roots at the lower lumbar levels which is still apparent in the more crowded proximal sections. In all cases, the axial images correlated precisely with the dissections. Current imaging modalities can help the clinical understanding and management of abnormalities in this region of the spine


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1062 - 1065
1 Sep 2002
Nishikawa S Toh S

There have been few descriptions of the site of attachment onto the triquetrum, the so-called meniscal homologue, of the triangular fibrocartilage complex (TFCC). We have investigated the sites of attachment onto the triquetrum of 87 TFCCs collected from embalmed cadavers. All TFCCs were smoothly attached to the triquetrum. In 79 (46 cases, 90%) they were attached to the triquetrum and fifth metacarpal bone, and in eight (5 cases, 10%) they were attached widely on the articular surface of the triquetrum. It is necessary to have accurate positional information about the normal triquetrum and TFCC in order to perform arthroscopy. The meniscal homologue attached to the triquetrum is smooth in almost all cases. In about 10% of joints the TFCC is attached to the lunotriquetral ligament, either partly or completely obscuring the articular surface of the triquetrum


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 819 - 824
1 Nov 1989
Amis A

The anteroposterior stability of cadaveric knees was investigated. There was a wide range of normal laxity; knees were more stable at 90 degrees than at 20 degrees flexion. Anterior cruciate ligament implants with different stiffnesses were inserted; normal stability could always be restored, and the stiffness or extensibility of implants did not affect knee behaviour significantly. The tightness of implants was critical--small tensioning errors caused subluxation, inhibited knee extension and allowed damagingly high implant tensions. It is concluded that the tension of ligament implants could not be adjusted simply with a pre-set instrument; the procedure will remain critically dependent on the judgment of the operating surgeon


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 432 - 437
1 May 1985
Silver R de la Garza J Rang M

The lower limbs of five cadavers were dissected and the lengths of the muscle fibres and the weights of all the muscles below the knee were measured. From this information the relative strength and excursion of each muscle was determined. We found that the plantarflexors of the ankle were six times as strong as the dorsiflexors. We have therefore discarded the concept of "muscle balance" in tendon transfer surgery and propose that task appropriateness should be the guide. The constant relationship between muscle fibre length and muscle excursion means that contractures are accompanied by decreased excursion. Tendon lengthening improves deformity but does not improve the decreased active range of movement


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 460 - 464
1 Nov 1980
McCullough C Burge P

The range of rotation of the talus in the horizontal plane was studied in the cadaveric ankle under conditions which simulated normal load-bearing. In the unloaded state there was 25 degrees of rotation, approximately half of which resulted from movement of the inferior tibiofibular joint. Rotation was load-dependent in both the intact ankle and in the ankle rendered unstable by division of the ligaments. Experimental division of the ligaments increased the range of rotation. The malleoli were contact areas during flexion and extension but excision of their articular surfaces caused only a moderate increase in rotation. The factors which limit talar rotation in intact and injured ankles are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 4 | Pages 735 - 741
1 Nov 1973
Krenz J Troup JDG

1. An anatomical study of the bony structure of the pars interarticularis of the fourth and fifth lumbar vertebrae has been made in specimens from seven cadavers aged seventeen to sixty-seven. 2. Layers of cortical bone have been described antero-laterally and postero-medially which are thickest in the narrowest region of the pars. 3. In one specimen from a seventeen-year-old male, a healing fracture was found in the antero-lateral layer of cortical bone in the right neural arch of the fourth lumbar vertebra. 4. The stresses to which the pars is subject consist primarily of shear forces applied to the articular processes. The significance of these stresses to the etiology of spondylolysis is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 448 - 454
1 Aug 1971
Aichroth P

1. In sixty mature rabbits osteochondral fractures of various types were made in the medial femoral condyle. 2. The fractures or fragments which remained stable united but those in which movement occurred progressed to non-union. 3. An ununited osteochondral fragment resembled osteochondritis dissecans in the human both radiologically and histologically. 4. Experiments in the cadaveric knee show that the patella articulates with the classical site on the intercondylar aspect of the medial femoral condyle in full flexion of the joint and here an osteochondral fracture could be sustained. 5. It is concluded that the fragment in osteochondritis dissecans follows an osteochondral fracture which remains ununited


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 680 - 683
1 Jul 1997
Kumar VP Satku K Liu J Shen Y

We studied the origin of the anterior deltoid from the lateral third of the clavicle and the leading anterior edge of the acromion in 18 cadaver shoulders by anatomical and histological methods. The main origin of the deltoid was from the superior surface of the anterior acromion, but muscle and tendinous attachments were also seen on the entire anterior surface of the acromion, its anteroinferior surface and on the whole width of the anterior surface of the clavicle. Mock arthroscopic acromioplasty was shown to detach deltoid fibres from the anterior surfaces, leaving the superior attachment in continuity. Potentially, arthroscopic subacromial and clavicular resection can detach deltoid fibres originating from the anterior and anteroinferior surfaces of the acromion and clavicle and thus weaken the anterior deltoid


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 452 - 458
1 May 1999
Stäubli H Dürrenmatt U Porcellini B Rauschning W

We studied the anatomy of the patellofemoral joint in the axial plane on cryosections from a cadaver knee and on MR arthrotomograms from 30 patients. The cryosections revealed differences in the geometry and anatomy of the surface of the articular cartilage and corresponding subchondral osseous contours of the patellofemoral joint. On the MR arthrotomograms the surface geometry of the cartilage matched the osseous contour of the patella in only four of the 30 knees. The articular cartilaginous surface of the intercondylar sulcus and corresponding osseous contour of the femoral trochlea matched in only seven knees. Since MR arthrotomography can distinguish between the surface geometry of the articular cartilage and subchondral osseous anatomy of the patellofemoral joint, it allows the surgeon and the radiologist to appraise the true articulating surfaces. We therefore recommend MR arthrotomography as the imaging technique of choice


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 452 - 455
1 May 1989
Nunn D Freeman M Tanner K Bonfield W

Torsional instability of femoral components has not received much attention, and is difficult to detect in conventional radiographs. To test this we designed a system to apply a load in an anteroposterior direction to the head of a femoral component, implanted into a cadaveric femur. Rotation within the bone was measured, using a purpose built transducer, with and without preservation of the neck, with and without cement, and with longitudinal ridges but no cement. The results show that torsional instability may be a problem in uncemented replacement. Preservation of the femoral neck and the use of a ridged prosthesis increases resistance to rotation. Rotational movements occurring in vivo during such activities as climbing stairs and rising from the seated position may contribute to mechanical loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 397 - 403
1 May 1988
Amis A

This study aimed to compare the holding strength of various commercially-available anchorage devices for artificial ligaments, so that surgeons might make a reasoned choice. Tensile tests to failure were performed on screws, bollards, toggles and staples which had been implanted into cadaveric bones. The holding strength of all devices correlated significantly with the local thickness of cortical bone, so it is recommended that anchorages should be placed away from the joint line, into diaphyseal bone if possible. A new trans-cortical grommet was developed which, when used around an AO screw, had significantly greater holding strength than the other devices


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 319 - 322
1 Jun 1982
Wicks M Garrett R Vernon-Roberts B Fazzalari N

A clinical, radiological and histopathological study of femoral heads from 125 patients with fracture of the neck of the femur and from 30 cadavers was carried out to identify various risk factors. The findings showed that the Singh index was unreliable as a radiological indicator of the bone content of the femoral heads; that the bone content of the femoral head in patients sustaining a fracture of the femoral neck did not differ from that of the controls; that osteomalacia was not found in any of the heads examined; and that the distribution of trabecular microfractures did not support the hypothesis that fracture of the neck was the result of progressive fatigue. It was concluded that the single most important factor leading to fracture in this Australian population was injury caused by falls and that such injury was frequently associated with other disease processes


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 572 - 576
1 Jul 1993
Knight D Rymaszewski L Amis A Miller J

Compression testing of cadaver specimens showed that excision of the radial head allowed proximal radial displacement. The insertion of a metallic radial head restored normal mechanics, while a silicone rubber implant did not. We reviewed 31 of 36 comminuted fractures of the radial head, 21 associated with dislocation or ulnar fracture, which had been treated by primary replacement with a Vitallium prosthesis. At a mean follow-up of 4.5 years, there was reliable restoration of stability and prevention of proximal radial migration. There had been no dislocations or prosthetic failures, but two implants had been removed for loosening. The prosthesis is recommended for use as a spacer to stabilise the elbow after severe injuries while the soft tissues heal


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 202 - 206
1 Mar 1993
Miller S Burkart B Damson E Shrive N Bray R

We used 15 pairs of femora from fresh human cadavers to study the effects of the size and location of the entry hole for an intramedullary nail on the strength of the femur. Right femora were used as controls. Left femora in group 1 had a 10 mm entry hole in the 'ideal' location in the piriformis fossa. Group 2 had a 14 mm entry hole in the same position and group 3 had a 14 mm entry hole anterior to this on the superior aspect of the femoral neck. Femora were equipped with strain gauges and loaded to failure in compression. There was reduced stiffness and load to failure in group 3 specimens, suggesting that the location of the hole was more important than its size


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 255 - 260
1 Mar 1985
Nakamura N Ellis M Seedhom B

The effects of advancement of the tibial tuberosity by inserting bony wedges was studied on cadaveric specimens of the knee. The geometry, the contact areas and the forces acting on the patellofemoral joint were investigated, and the forces acting on the tibiofemoral compartment were calculated. A 1 cm advancement was found to be optimal in reducing the high patellofemoral joint forces occurring at 90 degrees and 110 degrees of flexion, whilst causing least reduction of the contact areas; the stresses on the joint were reduced significantly. Advancement by 2 cm and by 3 cm drastically reduced the congruity and the size of the contact area. It was also shown that 2 cm and 3 cm advancement caused an increase in forces at the patellofemoral joint and also in the tibiofemoral joint in a direction tangential to the articular surfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 408 - 410
1 May 1984
Dymond I

The integrity of the periosteum and the interosseous membrane determine the stability of fractures of the distal ulna; this is indicated by the initial displacement. In fractures displaced by less than 50% the periosteum and interosseous membranes are largely intact; these fractures are stable and require only below-elbow immobilisation for protection and relief of pain. In fractures displaced by more than 50% the membranes are disrupted; these fractures are unstable and require above-elbow immobilisation for stability. As most fractures are displaced by less than 50%, immobilisation of the elbow, which significantly increases morbidity, is usually unnecessary. I report the results of a cadaveric study on the pathomechanics of fractures of the distal ulna, and of a prospective clinical trial in which the type of cast used for immobilisation was determined by the stability of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 474 - 482
1 Aug 1971
Wiley JJ

1. Twenty cases of tarso-metatarsal joint injury have been studied with regard to the mechanism of injury, and experiments have been done on cadavers to confirm clinical impressions. 2. Injuries of the tarso-metatarsal joints occur by direct and indirect mechanisms, the latter being more common. 3. Indirect injuries occur in at least two ways-namely, acute abduction of the forefoot and plantar-flexion of the forefoot. 4. Most of the indirect injuries occur when the ankle joint is in a plantar-flexed position. 5. Whereas this foot injury once gained prominence on the field of battle amongst cavalrymen, it is currently associated with the motor car, the step ladder, the toboggan, the joy-rider, and commonly the simple misguided step