Inherent disadvantages of reverse shoulder arthroplasty
designs based on the Grammont concept have raised a renewed interest
in less-medialised designs and techniques. The aim of this study
was to evaluate the outcome of reverse shoulder arthroplasty (RSA)
with the fully-constrained, less-medialised, Bayley–Walker prosthesis performed
for the treatment of rotator-cuff-deficient shoulders with glenohumeral
arthritis. A total of 97 arthroplasties in 92 patients (53 women
and 44 men, mean age 67 years (standard deviation ( The Bayley–Walker prosthesis provides reliable pain relief and
reasonable functional improvement for patients with symptomatic
cuff-deficient shoulders. Compared with other designs of RSA, it
offers a modest improvement in forward elevation, but restores external
rotation to some extent and prevents scapular notching. A longer
follow-up is required to assess the survival of the prosthesis and
the clinical performance over time. Cite this article:
Crescent fracture dislocations are a well-recognised subset of pelvic ring injuries which result from a lateral compression force. They are characterised by disruption of the sacroiliac joint and extend proximally as a fracture of the posterior iliac wing. We describe a classification with three distinct types. Type I is characterised by a large crescent fragment and the dislocation comprises no more than one-third of the sacroiliac joint, which is typically inferior. Type II fractures are associated with an intermediate-size crescent fragment and the dislocation comprises between one- and two-thirds of the joint. Type III fractures are associated with a small crescent fragment where the dislocation comprises most, but not all of the joint. The principal goals of surgical intervention are the accurate and stable reduction of the sacroiliac joint. This classification proves useful in the selection of both the surgical approach and the reduction technique. A total of 16 patients were managed according to this classification and achieved good functional results approximately two years from the time of the index injury. Confounding factors compromise the summary short-form-36 and musculoskeletal functional assessment instrument scores, which is a well-recognised phenomenon when reporting the outcome of high-energy trauma.
During open reduction of an irreducible anterior dislocation of a total hip replacement with an Oxinium femoral head, it was observed that the head had been significantly damaged. Gross and scanning electron microscopic examination revealed cracking, gouging, and delamination of the surface. Because of the risk which this poses for damaging the polyethylene acetabular liner, it is strongly recommended that patients with this type of prosthetic head be carefully monitored after a dislocation.
We reviewed the outcome of patients who had been
treated operatively for symptomatic peri-acetabular metastases and
present an algorithm to guide treatment. The records of 81 patients who had been treated operatively for
symptomatic peri-acetabular metastases between 1987 and 2010 were
identified. There were 27 men and 54 women with a mean age of 61
years (15 to 87). The diagnosis, size of lesion, degree of pelvic
continuity, type of reconstruction, World Health Organization performance
status, survival time, pain, mobility and complications including
implant failure were recorded in each case. The overall patient survivorship at five years was 5%. The longest
lived patient survived 16 years from the date of diagnosis. The
mean survival was 23 months (<
1 to 16 years) and the median
was 15 months. At follow-up 14 patients remained alive. Two cementoplasties
failed because of local disease progression. Three Harrington rods broke:
one patient needed a subsequent Girdlestone procedure. One ‘ice-cream
cone’ prosthesis dislocated and was subsequently revised without
further problems. We recommend the ‘ice-cream cone’ for pelvic discontinuity
and Harrington rod reconstruction for severe bone loss. Smaller
defects can be safely managed using standard revision hip techniques. Cite this article:
The outcome of displaced hips treated by Somerville and Scott’s method was assessed after more than 25 years. A total of 147 patients (191 displaced hips) was reviewed which represented an overall follow-up of 65.6%. The median age at the index operation was two years. During the first five years, 25 (13%) hips showed signs of avascular change. The late development of valgus angulation of the neck, after ten years, was seen in 69 (36%) hips. Further operations were frequently necessary. Moderate to severe osteoarthritis developed at a young age in 40% of the hips. Total hip replacement or arthrodesis was necessary in 27 (14%) hips at a mean age of 36.5 years. Risk factors identified were high dislocation, open reduction, and age at the original operation. Two groups of patients were compared according to outcome. All the radiographic indices were different between the two groups after ten years, but most were similar before. It takes a generation to establish the prognosis, although some early indicators may help to predict outcome.
There are several reports clarifying successful results following
open reduction using Ludloff’s medial approach for congenital (CDH)
or developmental dislocation of the hip (DDH). This study aimed
to reveal the long-term post-operative course until the period of
hip-joint maturity after the conventional surgical treatments. A long-term follow-up beyond the age of hip-joint maturity was
performed for 115 hips in 103 patients who underwent open reduction
using Ludloff’s medial approach in our hospital. The mean age at
surgery was 8.5 months (2 to 26) and the mean follow-up was 20.3
years (15 to 28). The radiological condition at full growth of the hip
joint was evaluated by Severin’s classification.Objectives
Methods
The most common injury in rugby resulting in
spinal cord injury (SCI) is cervical facet dislocation. We report
on the outcome of a series of 57 patients with acute SCI and facet
dislocation sustained when playing rugby and treated by reduction
between 1988 and 2000 in Conradie Hospital, Cape Town. A total of
32 patients were completely paralysed at the time of reduction.
Of these 32, eight were reduced within four hours of injury and
five of them made a full recovery. Of the remaining 24 who were
reduced after four hours of injury, none made a full recovery and only
one made a partial recovery that was useful. Our results suggest
that low-velocity trauma causing SCI, such as might occur in a rugby
accident, presents an opportunity for secondary prevention of permanent
SCI. In these cases the permanent damage appears to result from
secondary injury, rather than primary mechanical spinal cord damage.
In common with other central nervous system injuries where ischaemia
determines the outcome, the time from injury to reduction, and hence
reperfusion, is probably important. In order to prevent permanent neurological damage after rugby
injuries, cervical facet dislocations should probably be reduced
within four hours of injury.
We investigated the detailed anatomy of the gluteus
maximus, gluteus medius and gluteus minimus and their neurovascular
supply in 22 hips in 11 embalmed adult Caucasian human cadavers.
This led to the development of a surgical technique for an extended
posterior approach to the hip and pelvis that exposes the supra-acetabular
ilium and preserves the glutei during revision hip surgery. Proximal
to distal mobilisation of the gluteus medius from the posterior
gluteal line permits exposure and mobilisation of the superior gluteal
neurovascular bundle between the sciatic notch and the entrance
to the gluteus medius, enabling a wider exposure of the supra-acetabular
ilium. This technique was subsequently used in nine patients undergoing
revision total hip replacement involving the reconstruction of nine
Paprosky 3B acetabular defects, five of which had pelvic discontinuity.
Intra-operative electromyography showed that the innervation of
the gluteal muscles was not affected by surgery. Clinical follow-up
demonstrated good hip abduction function in all patients. These
results were compared with those of a matched cohort treated through
a Kocher–Langenbeck approach. Our modified approach maximises the
exposure of the ilium above the sciatic notch while protecting the
gluteal muscles and their neurovascular bundle. Cite this article: Bone Joint J 2014;96-B:48–53.
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group.
Pre-operative planning for total hip replacement
(THR) is challenging in hips with severe acetabular deformities, including
those with a hypoplastic acetabulum or severe defects and in the
presence of arthrodesis or ankylosis. We evaluated whether a Rapid
Prototype (RP) model, which is a life-sized reproduction based on
three-dimensional CT scans, can determine the feasibility of THR
and provide information about the size and position of the acetabular component
in severe acetabular deformities. THR was planned using an RP model
in 21 complex hips in five men (five hips) and 16 women (16 hips)
with a mean age of 47.7 years (24 to 70) at operation. An acetabular
component was implanted successfully and THR completed in all hips.
The acetabular component used was within 2 mm of the predicted size
in 17 hips (80.9%). All of the acetabular components and femoral
stems had radiological evidence of bone ingrowth and stability at
the final follow-up, without any detectable wear or peri-prosthetic
osteolysis. The RP model allowed a simulated procedure pre-operatively
and was helpful in determining the feasibility of THR pre-operatively,
and to decide on implant type, size and position in complex THRs. Cite this article:
Increased femoral head size may reduce dislocation rates following total hip replacement. The National Joint Registry for England and Wales has highlighted a statistically significant increase in the use of femoral heads ≥ 36 mm in diameter from 5% in 2005 to 26% in 2009, together with an increase in the use of the posterior approach. The aim of this study was to determine whether rates of dislocation have fallen over the same period. National data for England for 247 546 procedures were analysed in order to determine trends in the rate of dislocation at three, six, 12 and 18 months after operation during this time. The 18-month revision rates were also examined. Between 2005 and 2009 there were significant decreases in cumulative dislocations at three months (1.12% to 0.86%), six months (1.25% to 0.96%) and 12 months (1.42% to 1.11%) (all p <
0.001), and at 18 months (1.56% to 1.31%) for the period 2005 to 2008 (p <
0.001). The 18-month revision rates did not significantly change during the study period (1.26% to 1.39%, odds ratio 1.10 (95% confidence interval 0.98 to 1.24), p = 0.118). There was no evidence of changes in the coding of dislocations during this time. These data have revealed a significant reduction in dislocations associated with the use of large femoral head sizes, with no change in the 18-month revision rate.
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for patients with unstable trochanteric proximal
femoral fractures. The recognised treatment alternatives are extramedullary
fixation usually with a sliding hip screw and intramedullary fixation
with a cephalomedullary nail. Current evidence suggests that best
results and lowest complication rates occur using a sliding hip screw.
Complications in these difficult fractures are relatively common
regardless of type of treatment. We believe that a novel device,
the X-Bolt dynamic plating system, may offer superior fixation over
a sliding hip screw with lower reoperation risk and better function.
We therefore propose to investigate the clinical effectiveness of
the X-bolt dynamic plating system compared with standard sliding
hip screw fixation within the framework of a the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
The October 2013 Children’s orthopaedics Roundup360 looks at: Half a century of Pavlik treatment; Step away from the child!: trends in fracture management; Posterolateral rotatory elbow instability in children; Osteochondral lesions undiagnosed in patellar dislocations; Oral bisphosphonates in osteogenesis imperfecta; Crossed or parallel pins in supracondylar fractures?; Not too late nor too early: getting epiphysiodesis right; Fixation of supramalleolar osteotomies.
The purpose of this study was to investigate
the development of the osseous acetabular index (OAI) and cartilaginous
acetabular index (CAI) using MRI. The OAI and CAI were measured
on the coronal MR images of the hip in 81 children with developmental
dysplasia of the hip (DDH), with a mean age of 19.6 months (3 to
70), and 241 normal control children with a mean age of 5.1 years
(1 month to 12.5 years). Additionally the developmental patterns
of the OAI and CAI in normal children were determined by age-based
cross-sectional analysis. Unlike the OAI, the normal CAI decreased rapidly from a mean
of 10.17° (
We investigated the functional outcome in patients
who underwent reverse shoulder replacement (RSR) after removal of
a tumour of the proximal humerus. A total of 16 patients (ten women
and six men) underwent this procedure between 1998 and 2011 in our
hospital. Five patients died and one was lost to follow-up. Ten
patients were available for review at a mean follow-up of 46 months
(12 to 136). Eight patients had a primary and two patients a secondary
bone tumour. At final follow up the mean range of active movement was: abduction
78° (30° to 150°); flexion 98° (45° to 180°); external rotation
32° (10° to 60°); internal rotation 51° (10° to 80°). The mean Musculoskeletal
Tumor Society score was 77% (60% to 90%) and the mean Toronto Extremity
Salvage Score was 70% (30% to 91%). Two patients had a superficial
infection and one had a deep infection and underwent a two-stage
revision procedure. In two patients there was loosening of the RSR;
one dislocated twice. All patients had some degree of atrophy or
pseudo-atrophy of the deltoid muscle. Use of a RSR in patients with a tumour of the proximal humerus
gives acceptable results. Cite this article:
We present a case of early retrieval of an Oxinium femoral head and corresponding polyethylene liner where there was significant surface damage to the head and polyethylene. The implants were retrieved at the time of revision surgery to correct leg-length discrepancy just 48 hours after the primary hip replacement. Appropriate analysis of the retrieved femoral head demonstrated loss of the Oxinium layer with exposure of the underlying substrate and transfer of titanium from the acetabular shell at the time of a reduction of the index total hip replacement. In addition, the level of damage to the polyethylene was extensive despite only 48 hours The purpose of this report is to highlight the care that is required at the time of reduction, especially with these hard femoral counter-faces such as Oxinium. To our knowledge, the damage occurring at the time of reduction has not been previously reported following the retrieval of an otherwise well-functioning hip replacement.
The National Institute for Health and Clinical
Excellence (NICE) guidelines from 2011 recommend the use of cemented
hemi-arthroplasty for appropriate patients with an intracapsular
hip fracture. In our institution all patients who were admitted
with an intracapsular hip fracture and were suitable for a hemi-arthroplasty
between April 2010 and July 2012 received an uncemented prosthesis
according to our established departmental routine practice. A retrospective
analysis of outcome was performed to establish whether the continued
use of an uncemented stem was justified. Patient, surgical and outcome
data were collected on the National Hip Fracture database. A total
of 306 patients received a Cathcart modular head on a Corail uncemented
stem as a hemi-arthroplasty. The mean age of the patients was 83.3
years ( Cite this article:
The use of recombinant human bone morphogenetic protein-2 (rhBMP-2) for the treatment of congenital pseudarthrosis of the tibia has been investigated in only one previous study, with promising results. The aim of this study was to determine whether rhBMP-2 might improve the outcome of this disorder. We reviewed the medical records of five patients with a mean age of 7.4 years (2.3 to 21) with congenital pseudarthrosis of the tibia who had been treated with rhBMP-2 and intramedullary rodding. Ilizarov external fixation was also used in four of these patients. Radiological union of the pseudarthrosis was evident in all of them at a mean of 3.5 months (3.2 to 4) post-operatively. The Ilizarov device was removed after a mean of 4.2 months (3.0 to 5.3). These results indicate that treatment of congenital pseudarthrosis of the tibia using rhBMP-2 in combination with intramedullary stabilisation and Ilizarov external fixation may improve the initial rate of union and reduce the time to union. Further studies with more patients and longer follow-up are necessary to determine whether this surgial procedure may significantly enhance the outcome of congenital pseudarthrosis of the tibia, considering the refracture rate (two of five patients) in this small case series.
Impaction bone grafting for the reconstitution
of bone stock in revision hip surgery has been used for nearly 30 years.
Between 1995 and 2001 we used this technique in acetabular reconstruction,
in combination with a cemented component, in 304 hips in 292 patients
revised for aseptic loosening. The only additional supports used
were stainless steel meshes placed against the medial wall or laterally
around the acetabular rim to contain the graft. All Paprosky grades
of defect were included. Clinical and radiographic outcomes were
collected in surviving patients at a minimum of ten years after
the index operation. Mean follow-up was 12.4 years ( Cite this article:
Fractures of the proximal interphalangeal joint include a wide spectrum of injuries, from stable avulsion fractures to complex fracture-dislocations. Stability of the joint is paramount in determining the appropriate treatment, which should aim to facilitate early mobilisation and restoration of function.