Nerve palsy is a well-described complication
following total hip arthroplasty, but is highly distressing and
disabling. A nerve palsy may cause difficulty with the post-operative
rehabilitation, and overall mobility of the patient. Nerve palsy
may result from compression and tension to the affected nerve(s)
during the course of the operation via surgical manipulation and
retractor placement, tension from limb lengthening or compression
from post-operative hematoma. In the literature, hip dysplasia,
lengthening of the leg, the use of an uncemented femoral component, and
female gender are associated with a greater risk of nerve palsy.
We examined our experience at a high-volume, tertiary care referral
centre, and found an overall incidence of 0.3% out of 39 056 primary
hip arthroplasties. Risk factors found to be associated with the
incidence of nerve palsy at our institution included the presence
of spinal stenosis or lumbar disc disease, age younger than 50,
and smoking. If a nerve palsy is diagnosed, imaging is mandatory
and surgical evacuation or compressive haematomas may be beneficial.
As palsies are slow to recover, supportive care such as bracing,
therapy, and reassurance are the mainstays of treatment. Cite this article:
Tantalum (Ta) trabecular metal components are increasingly used
to reconstruct major bone defects in revision arthroplasty surgery.
It is known that some metals such as silver have antibacterial properties.
Recent reports have raised the question regarding whether Ta components
are protective against infection in revision surgery. This laboratory
study aimed to establish whether Ta has intrinsic antibacterial
properties against planktonic bacteria, or the ability to inhibit
biofilm formation. Equal-sized pieces of Ta and titanium (Ti) acetabular components
were sterilised and incubated with a low dose inoculum of either Aims
Materials and Methods
In the present study, we aimed to assess whether gelatin/β-tricalcium phosphate (β-TCP) composite porous scaffolds could be used as a local controlled release system for vancomycin. We also investigated the efficiency of the scaffolds in eliminating infections and repairing osteomyelitis defects in rabbits. The gelatin scaffolds containing differing amounts of of β-TCP (0%, 10%, 30% and 50%) were prepared for controlled release of vancomycin and were labelled G-TCP0, G-TCP1, G-TCP3 and G-TCP5, respectively. The Kirby-Bauer method was used to examine the release profile. Chronic osteomyelitis models of rabbits were established. After thorough debridement, the osteomyelitis defects were implanted with the scaffolds. Radiographs and histological examinations were carried out to investigate the efficiency of eliminating infections and repairing bone defects.Objective
Methods
Temperature is known to influence muscle physiology, with the velocity of shortening, relaxation and propagation all increasing with temperature. Scant data are available, however, regarding thermal influences on energy required to induce muscle damage. Gastrocnemius and soleus muscles were harvested from 36 male rat limbs and exposed to increasing impact energy in a mechanical test rig. Muscle temperature was varied in 5°C increments, from 17°C to 42°C (to encompass the Objectives
Methods
Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis component and the adjacent bone. Composite tibias were implanted with fixed and RP primary and revision tibial trays and biomechanically tested under up to 2.5 kN of axial compression and 10° of external femoral component rotation. Relative micromotion between the implanted tibial tray and the neighbouring bone was quantified using high-precision digital image correlation techniques.Objectives
Methods
The purpose of this study was to compare the clinical and radiographic
outcomes of total ankle arthroplasty (TAA) in patients with pre-operatively
moderate and severe arthritic varus ankles to those achieved for
patients with neutral ankles. A total of 105 patients (105 ankles), matched for age, gender,
body mass index, and follow-up duration, were divided into three
groups by pre-operative coronal plane tibiotalar angle; neutral
(<
5°), moderate (5° to 15°) and severe (>
15°) varus deformity.
American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot
score, a visual analogue scale (VAS), and Short Form (SF)-36 score
were used to compare the clinical outcomes after a mean follow-up period
of 51 months (24 to 147).Aims
Patients and Methods
Infection following total hip or knee arthroplasty is a serious
complication. We noted an increase in post-operative infection in
cases carried out in temporary operating theatres. We therefore
compared those cases performed in standard and temporary operating
theatres and examined the deep periprosthetic infection rates. A total of 1223 primary hip and knee arthroplasties were performed
between August 2012 and June 2013. A total of 539 (44%) were performed
in temporary theatres. The two groups were matched for age, gender,
body mass index and American Society of Anesthesiologists grade.Aims
Patients and methods
The interaction between surgical lighting and laminar airflow
is poorly understood. We undertook an experiment to identify any
effect contemporary surgical lights have on laminar flow and recommend
practical strategies to limit any negative effects. Neutrally buoyant bubbles were introduced into the surgical field
of a simulated setup for a routine total knee arthroplasty in a
laminar flow theatre. Patterns of airflow were observed and the
number of bubbles remaining above the surgical field over time identified.
Five different lighting configurations were assessed. Data were analysed
using simple linear regression after logarithmic transformation.Aims
Materials and Methods
Periprosthetic femoral fractures (PFF) following total hip arthroplasty
(THA) are devastating complications that are associated with functional
limitations and increased overall mortality. Although cementless
implants have been associated with an increased risk of PFF, the
precise contribution of implant geometry and design on the risk
of both intra-operative and post-operative PFF remains poorly investigated.
A systematic review was performed to aggregate all of the PFF literature
with specific attention to the femoral implant used. A systematic search strategy of several journal databases and
recent proceedings from the American Academy of Orthopaedic Surgeons
was performed. Clinical articles were included for analysis if sufficient
implant description was provided. All articles were reviewed by
two reviewers. A review of fundamental investigations of implant
load-to-failure was performed, with the intent of identifying similar
conclusions from the clinical and fundamental literature.Aims
Patients and Methods
Advances in polyethylene (PE) in total hip arthroplasty
have led to interest and increased use of highly crosslinked PE
(HXLPE) in total knee arthroplasty (TKA). Biomechanical data suggest
improved wear characteristics for HXLPE inserts over conventional
PE in TKA. Short-term results from registry data and few clinical
trials are promising. Our aim is to present a review of the history
of HXLPEs, the use of HXLPE inserts in TKA, concerns regarding potential mechanical
complications, and a thorough review of the available biomechanical
and clinical data. Cite this article:
Tibial nonunion represents a spectrum of conditions
which are challenging to treat, and optimal management remains unclear
despite its high rate of incidence. We present 44 consecutive patients
with 46 stiff tibial nonunions, treated with hexapod external fixators
and distraction to achieve union and gradual deformity correction.
There were 31 men and 13 women with a mean age of 35 years (18 to
68) and a mean follow-up of 12 months (6 to 40). No tibial osteotomies
or bone graft procedures were performed. Bony union was achieved
after the initial surgery in 41 (89.1%) tibias. Four persistent
nonunions united after repeat treatment with closed hexapod distraction,
resulting in bony union in 45 (97.8%) patients. The mean time to
union was 23 weeks (11 to 49). Leg-length was restored to within
1 cm of the contralateral side in all tibias. Mechanical alignment
was restored to within 5° of normal in 42 (91.3%) tibias. Closed
distraction of stiff tibial nonunions can predictably lead to union
without further surgery or bone graft. In addition to generating
the required distraction to achieve union, hexapod circular external
fixators can accurately correct concurrent deformities and limb-length
discrepancies. Cite this article:
The aim of this study was to report the outcome of the non-operative
treatment of high-grade posterior cruciate ligament (PCL) injuries,
particularly Hughston grade III injuries, which have not previously
been described. This was a prospective study involving 46 consecutive patients
who were athletes with MRI-confirmed isolated PCL injuries presenting
within four weeks of injury. All had Hughston grade II (25 athletes)
or III (21 athletes) injuries. Our non-operative treatment regimen
involved initial bracing, followed by an individualised rehabilitation
programme determined by the symptoms and physical signs. The patients
were reviewed until they had returned to sports-specific training,
and were reviewed again at a mean of 5.2 years (3 to 9).Aims
Patients and Methods
Cellular movement and relocalisation are important for many physiologic properties. Local mesenchymal stem cells (MSCs) from injured tissues and circulating MSCs aid in fracture healing. Cytokines and chemokines such as Stromal cell-derived factor 1(SDF-1) and its receptor chemokine receptor type 4 (CXCR4) play important roles in maintaining mobilisation, trafficking and homing of stem cells from bone marrow to the site of injury. We investigated the differences in migration of MSCs from the femurs of young, adult and ovariectomised (OVX) rats and the effect of CXCR4 over-expression on their migration. MSCs from young, adult and OVX rats were put in a Boyden chamber to establish their migration towards SDF-1. This was compared with MSCs transfected with CXCR4, as well as MSCs differentiated to osteoblasts.Objectives
Methods
Hip and groin injuries are common in athletes
who take part in high level sports. Adductor muscle tendon injuries represent
a small but important number of these injuries. Avulsion of the
tendons attached to the symphysis pubis has previously been described:
these can be managed both operatively and non-operatively. We describe
an uncommon variant of this injury, namely complete avulsion of
the adductor sleeve complex: this includes adductor longus, pectineus
and rectus abdominis. We go on to describe a surgical technique
which promotes a full return to the pre-injury level of sporting
activity. Over a period of ten years, 15 high-level athletes with an MRI-confirmed
acute adductor complex avulsion injury (six to 34 days old) underwent
surgical repair. The operative procedure consisted of anatomical
re-attachment of the avulsed tissues in each case and mesh reinforcement
of the posterior inguinal wall in seven patients. All underwent a
standardised rehabilitation programme, which was then individualised
to be sport-specific. One patient developed a superficial wound infection, which was
successfully treated with antibiotics. Of the 15 patients, four
complained of transient local numbness which resolved in all cases.
All patients (including seven elite athletes) returned to their
previous level of participation in sport. Cite this article:
Extracorporeal irradiation of an excised tumour-bearing
segment of bone followed by its re-implantation is a technique used
in bone sarcoma surgery for limb salvage when the bone is of reasonable
quality. There is no agreement among previous studies about the
dose of irradiation to be given: up to 300 Gy have been used. We investigated the influence of extracorporeal irradiation on
the elastic and viscoelastic properties of bone. Bone was harvested
from mature cattle and subdivided into 13 groups: 12 were exposed
to increasing levels of irradiation: one was not and was used as
a control. The specimens, once irradiated, underwent mechanical
testing in saline at 37°C. The mechanical properties of each group, including Young’s modulus,
storage modulus and loss modulus, were determined experimentally
and compared with the control group. There were insignificant changes in all of these mechanical properties
with an increasing level of irradiation. We conclude that the overall mechanical effect of high levels
of extracorporeal irradiation (300 Gy) on bone is negligible. Consequently
the dose can be maximised to reduce the risk of local tumour recurrence. Cite this article:
Thermal stability is a key property in determining the suitability of an antibiotic agent for local application in the treatment of orthopaedic infections. Despite the fact that long-term therapy is a stated goal of novel local delivery carriers, data describing thermal stability over a long period are scarce, and studies that avoid interference from specific carrier materials are absent from the orthopaedic literature. In this study, a total of 38 frequently used antibiotic agents were maintained at 37°C in saline solution, and degradation and antibacterial activity assessed over six weeks. The impact of an initial supplementary heat exposure mimicking exothermically curing bone cement was also tested as this material is commonly used as a local delivery vehicle. Antibiotic degradation was assessed by liquid chromatography coupled to mass spectrometry, or by immunoassays, as appropriate. Antibacterial activity over time was determined by the Kirby-Bauer disk diffusion assay.Objectives
Methods
To assess the extent of osteointegration in two designs of shoulder
resurfacing implants. Bony integration to the Copeland cylindrical
central stem design and the Epoca RH conical-crown design were compared. Implants retrieved from six patients in each group were pair-matched.
Mean time to revision surgery of Copeland implants was 37 months
(standard deviation (Aims
Patients and Methods