Advertisement for orthosearch.org.uk
Results 21 - 40 of 2316
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1565 - 1571
1 Dec 2018
Kristensen TB Dybvik E Furnes O Engesæter LB Gjertsen J

Aims. The aim of this large registry-based study was to compare mid-term survival rates of cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck. Patients and Methods. From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included. Polished tapered stems (n = 12 065) (Exeter and CPT), straight stems (n = 5545) (Charnley, Charnley Modular, and Spectron EF), and anatomical stems (n = 2922) (Lubinus SP2) were included. The survival of the implant with any reoperation as the endpoint was calculated using the Kaplan–Meier method and hazard ratios (HRs), and the different indications for reoperation were calculated using Cox regression analysis. Results. The one-year survival was 96.0% (95% confidence interval (CI) 95.6 to 96.4) for the Exeter stem, 97.0% (95% CI 96.4 to 97.6) for the Lubinus SP2 stem, 97.6% (95% CI 97.0 to 98.2) for the Charnley stem, 98.1% (95% CI 97.3 to 98.9) for the Spectron EF stem, and 96.4% (95% CI 95.6 to 97.2) for the Charnley Modular stem, respectively. The hazard ratio for reoperation after one year was lower for Lubinus SP2 (HR 0.77, 95% CI 0.60 to 0.97), Charnley (HR 0.64, 95% CI 0.48 to 0.86), and Spectron EF stems (HR 0.44, 95% CI 0.29 to 0.67) compared with the Exeter stem. Reoperation for periprosthetic fracture occurred almost exclusively after the use of polished tapered stems. Conclusion. We were able to confirm that implant survival after cemented hemiarthroplasty for a hip fracture is high. Differences in rates of reoperation seem to favour anatomical and straight stems compared with polished tapered stems, which had a higher risk of periprosthetic fracture


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined. . The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded. The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (. sd. 4.0) and 4.6 mm (. sd. 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (. sd. 4.6) and 6.4 mm (. sd. 4.6), respectively. Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset. Cite this article: Bone Joint J 2014;96-B:1274–81


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 603 - 609
1 May 2018
Schnetzke M Rick S Raiss P Walch G Loew M

Aims. The aim of this study was to evaluate the clinical and radiological outcome of using an anatomical short-stem shoulder prosthesis to treat primary osteoarthritis of the glenohumeral joint. Patients and Methods. A total of 66 patients (67 shoulders) with a mean age of 76 years (63 to 92) were available for clinical and radiological follow-up at two different timepoints (T1, mean 2.6 years, . sd. 0.5; T2, mean 5.3 years,. sd. 0.7). Postoperative radiographs were analyzed for stem angle, cortical contact, and filling ratio of the stem. Follow-up radiographs were analyzed for timing and location of bone adaptation (cortical bone narrowing, osteopenia, spot welds, and condensation lines). The bone adaptation was classified as low (between zero and three features of bone remodelling around the humeral stem) or high (four or more features). Results. The mean Constant score improved significantly from 28.5 (. sd. 11.6) preoperatively to 75.5 (. sd. 8.5) at T1 (p < 0.001) and remained stable over time (T2: 76.6, . sd. 10.2). No stem loosening was seen. High bone adaptation was present in 42% of shoulders at T1, with a slight decrease to 37% at T2. Cortical bone narrowing and osteopenia in the region of the calcar decreased from 76% to 66% between T1 and T2. Patients with high bone adaptation had a significantly higher mean filling ratio of the stem at the metaphysis (0.60, . sd. 0.05 vs 0.55, . sd. 0.06; p = 0.003) and at the diaphysis (0.65 . sd. 0.05 vs 0.60 . sd. 0.05; p = 0.007). Cortical contact of the stem was also associated with high bone adaptation (14/25 shoulders, p = 0.001). The clinical outcome was not influenced by the radiological changes. Conclusion. Total shoulder arthroplasty using a short-stem humeral component resulted in good clinical outcomes with no evidence of loosening. However, approximately 40% of the shoulders developed substantial bone loss in the proximal humerus at between four and seven years of follow-up. Cite this article: Bone Joint J 2018;100-B:603–9


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 623 - 627
1 May 2005
Kim Y

Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration of the clinical and radiological follow-up was 19.4 years (18 to 20). The mean Harris hip score initially improved from 55 points before to 95 points at two years after operation, but subsequently decreased to 91 points after six years, 87 points after 11.2 years, and 85 points after 19.4 years. At the final follow-up, 23 hips (18%) of the entire cohort and 21% of survivors had undergone revision because of loosening or osteolysis of the acetabular component and eight hips (6%) of the entire cohort and 7% of survivors for loosening or osteolysis of the femoral component. Only four femoral components (4%) were revised for isolated aseptic loosening without osteolysis and two (2%) for recurrent dislocation. On the basis of these long-term results, the porous-coated anatomic femoral component survived for a minimum of 18 years after operation while the acetabular component was less durable. The findings identify the principles of uncemented joint replacement which can be applied to current practice


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 745 - 749
1 Jun 2009
Ritter MA

The long-term success of total knee replacement is multifactorial, including factors relating to the patient, the operation and the implant. The purpose of this study was to examine the 20-year survival of the cemented Anatomical Graduated Component (AGC) total knee replacement. Between 1983 and 2004, 7760 of these were carried out at our institution. Of these, 6726 knees which received the non-modular metal-backed tibial component with compression-moulded polyethylene and had a minimum two-year follow-up were available for study. In all, 36 knees were followed over 20 years with a survival of the tibial and femoral components together of 97.8% (95% confidence interval (CI) 0.9851 to 0.9677), with no implants being revised for polyethylene wear or osteolysis. Age > 70 was associated with increased survival (99.6%, 95% CI 99.0 to 99.8) (p < 0.0001) but pre-operative valgus alignment reduced survival (95.1%, 95% CI 90.0 to 97.6) (p = 0.0056). Age < 55 (p = 0.129), pre-operative varus alignment (p = 0.707), osteonecrosis (p = 0.06), rheumatoid arthritis (p = 0.247), and gender (p = 0.666) were not statistically associated with failure. We attribute the success of the AGC implant to its relatively unconstrained articular geometry and the durability of a non-modular metal-backed tibial component with compression moulded polyethylene


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 232 - 236
1 Mar 2002
Krips R Brandsson S Swensson C van Dijk CN Karlsson J

In this retrospective study, we assessed the outcome in 99 patients who underwent reconstruction of the lateral ligaments of the ankle for chronic anterolateral instability with a minimum follow-up of 15 years. Two techniques were compared: 54 patients had an anatomical reconstruction (AR group) and 45 had an Evans tenodesis (ET group). They were followed up for 19.9 ± 3.6 years and 21.8 ± 4.6 years, respectively. During follow-up, seven patients in the AR group and 17 in the ET group required a further operation (p = 0.004). At follow-up, significantly more patients (n = 15) in the ET group had limited dorsiflexion than in the AR group (n = 6, p = 0.007) and 18 in the ET group had a positive anterior drawer test compared with seven in the AR group (p = 0002). In the ET group 27 had tenderness on palpation of the ankle compared with 15 in the AR group (p = 0.001). Stress radiographs showed ligamentous laxity significantly more often in the ET group (n = 30) than in the AR group (n = 13, p < 0.001). The mean values for talar tilt and anterior talar translation were significantly higher in the ET group than in the AR group (p < 0.001, p = 0.007, respectively). There were degenerative changes on standard radiographs in 32 patients in the AR group and 35 in the ET group (p = 0.05). Four patients in the ET group had developed severe osteoarthritis compared with none in the AR group (p = 0.025). Assessment of functional stability revealed a mean Karlsson score of 83.7 ± 10.4 points in the AR group and 67.0 ± 15.8 points in the ET group (p < 0.001). According to the Good rating system, 43 patients in the AR group had good or excellent results compared with 15 in the ET group (p < 0.001). Compared with anatomical reconstruction, the Evans tenodesis does not prevent laxity in a large number of patients. Long-standing ligamentous laxity leads to degenerative change in the ankle, resulting in chronic pain, limited dorsiflexion and further operations. The functional result deteriorates more rapidly after the Evans tenodesis than after anatomical reconstruction


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1183 - 1189
1 Sep 2017
Cho BK Kim YM Choi SM Park HW SooHoo NF

Aims. The aim of this prospective study was to evaluate the intermediate-term outcomes after revision anatomical ankle ligament reconstruction augmented with suture tape for a failed modified Broström procedure. Patients and Methods. A total of 30 patients with persistent instability of the ankle after a Broström procedure underwent revision augmented with suture tape. Of these, 24 patients who were followed up for more than two years were included in the study. There were 13 men and 11 women. Their mean age was 31.8 years (23 to 44). The mean follow-up was 38.5 months (24 to 56) The clinical outcome was assessed using the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measure (FAAM) score. The stability of the ankle was assessed using stress radiographs. Results. The mean FAOS and FAAM scores improved significantly to 87.5 (73 to 94) and 85.1 (70 to 95) points at final follow-up, respectively (p < 0.001). The mean angle of talar tilt and anterior talar translation improved significantly to 2.8° (0° to 6°) and 4.1 mm (2 to 7) at final follow-up, respectively (p < 0.001). Side to side comparison in stress radiographs at final follow-up showed no significant difference. The revision failed in one patient who underwent a further revision using allograft tendon. Conclusion. The revision modified Broström procedure augmented with suture tape is an effective form of treatment for recurrent instability of the ankle following a failed Broström procedure. This technique provides reliable stability and satisfactory clinical outcomes at intermediate-term follow-up. Cite this article: Bone Joint J 2017;99-B:1183–9


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 789 - 794
1 Jun 2014
Sukegawa K Kuniyoshi K Suzuki T Ogawa Y Okamoto S Shibayama M Kobayashi T Takahashi K

We conducted an anatomical study to determine the best technique for transfer of the anterior interosseous nerve (AIN) for the treatment of proximal ulnar nerve injuries. The AIN, ulnar nerve, and associated branches were dissected in 24 cadaver arms. The number of branches of the AIN and length available for transfer were measured. The nerve was divided just proximal to its termination in pronator quadratus and transferred to the ulnar nerve through the shortest available route. Separation of the deep and superficial branches of the ulnar nerve by blunt dissection alone, was also assessed. The mean number of AIN branches was 4.8 (3 to 8) and the mean length of the nerve available for transfer was 72 mm (41 to 106). The transferred nerve reached the ulnar nerve most distally when placed dorsal to flexor digitorum profundus (FDP). We therefore conclude that the AIN should be passed dorsal to FDP, and that the deep and superficial branches of the ulnar nerve require approximately 30 mm of blunt dissection and 20 mm of sharp dissection from the point of bifurcation to the site of the anastomosis. The use of this technique for transfer of the AIN should improve the outcome for patients with proximal ulnar nerve injuries. Cite this article: Bone Joint J 2014;96-B:789–94


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 224 - 228
1 Feb 2014
Simone JP Streubel PH Athwal GS Sperling JW Schleck CD Cofield RH

We assessed the clinical results, radiographic outcomes and complications of patients undergoing total shoulder replacement (TSR) for osteoarthritis with concurrent repair of a full-thickness rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%) undergoing TSR for osteoarthritis underwent rotator cuff repair. The final study group comprised 33 patients with a mean follow-up of 4.7 years (3 months to 13 years). Tears were classified into small (10), medium (14), large (9) or massive (0). On a scale of 1 to 5, pain decreased from a mean of 4.7 to 1.7 (p = < 0.0001), the mean forward elevation improved from 99° to 139° (p = < 0.0001), and the mean external rotation improved from 20° (0° to 75°) to 49° (20° to 80°) (p = < 0.0001). The improvement in elevation was greater in those with a small tear (p = 0.03). Radiographic evidence of instability developed in six patients with medium or large tears, indicating lack of rotator cuff healing. In all, six glenoid components, including one with instability, were radiologically at risk of loosening. Complications were noted in five patients, all with medium or large tears; four of these had symptomatic instability and one sustained a late peri-prosthetic fracture. Four patients (12%) required further surgery, three with instability and one with a peri-prosthetic humeral fracture. . Consideration should be given to performing rotator cuff repair for stable shoulders during anatomical TSR, but reverse replacement should be considered for older, less active patients with larger tears. Cite this article: Bone Joint J 2014;96-B:224–8


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 258 - 262
1 Mar 1994
Owen T Moran C Smith Pinder I

We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed giant macrophages incorporating numerous particles of high-density polyethylene. The femoral failures were related to a poor intramedullary fit with subsequent subsidence. Using the recommendation for revision as the end point, the cumulative survival rate for prostheses was 91% at six years (95% CI +/- 6%), 73% (+/- 11%) at seven years, and 57% (+/- 20%) at eight years. The result of uncemented PCA hip replacement is satisfactory up to six years, but then increasing failure of the acetabular component appears to be due to polyethylene wear, leading to osteolysis, loosening and component migration. At first, failure is often asymptomatic; routine follow-up of uncemented hip replacement is essential, especially after five years


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 587 - 592
1 May 2011
Kim Y Kim J Park J Joo J

We reviewed the results of 84 total hip replacements performed with a short metaphyseal-fitting anatomical cementless femoral component in 84 unselected consecutive patients with a mean age of 78.9 years (70 to 88). The mean follow-up was 4.6 years (4 to 5). The mean pre-operative Harris hip score was 26 points (0 to 56), which improved to 89 (61 to 100) at the final follow-up. No patient had thigh pain. The mean pre-operative Western Ontario and McMaster Universities osteoarthritis index score was 61 points (48 to 75), which improved to 21 (6 to 46). The mean University of California, Los Angeles activity score was 5.5 points (3 to 7) at the final follow-up. Osseointegration was seen in all femoral and acetabular components. All hips had grade 1 stress shielding of the proximal femur. No acetabular or femoral osteolysis was identified. These results demonstrate that a short metaphyseal-fitting femoral component achieves optimal fixation without diaphyseal anchorage in elderly patients


Bone & Joint Research
Vol. 8, Issue 9 | Pages 437 - 437
2 Sep 2019
Pękala PA Henry BM Pękala JR Piska K Tomaszewski KA


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1495 - 1497
1 Nov 2007
Jones BG Mehin R Young D

Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw. The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 79 - 86
1 Jan 2000
Mehta JA Bain GI Heptinstall RJ

We treated 31 intra-articular fractures of the distal radius by arthroscopically-assisted reduction and percutaneous fixation with Kirschner (K-) wires. Tears of the triangular fibrocartilage (58%), scapholunate (85%) and lunotriquetral (61%) instability and osteochondral lesions (19%) were also treated. A total of 26 patients was independently reviewed at an average of 19 months. The mean pain score was 1.3/10, the range of movement 79% and the grip strength 90% of the contralateral wrist. Using the New York Orthopaedic Hospital score, 88% were graded excellent to good. On follow-up radiographs, 65% had no step and 31% had a step of ≤1 mm. Pain was significantly related to the size of the step. There was a significant difference in the incidence of persistent scapholunate diastasis and the Leibovic and Geissler grade (p < 0.01): I (0%), II (0%), III (42%) and IV (100%). We recommend anatomical reduction and acceptance of a step of < 1 mm since the size of the step is related to the incidence of pain


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 327 - 332
1 Mar 2009
García-Rey E García-Cimbrelo E Cordero-Ampuero J

We reviewed 111 hemispherical Duraloc series-500 acetabular components with a minimum follow-up of 12 years. The mean clinical and radiological follow-up was 13.4 years (12 to 15). A Profile hydroxyapatite-coated anatomical femoral component was used in each case. Six patients had a late dislocation, for whom the polyethylene liner was exchanged. Each acetabular component was well fixed and all femoral components showed signs of bone ingrowth. The mean rate of femoral head penetration was 0.10 mm/year (0.021 to 0.481). The probability of not developing femoral cortical hypertrophy and proximal osteopenia by 12 years was 80.2% (95% confidence interval, 72.7 to 87.6) and 77.5% (95% confidence interval, 69.7 to 85.2), respectively. Despite these good clinical results, further follow-up is needed to determine whether these prostheses will loosen with time


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 424 - 429
1 Mar 2013
Madan SS Cooper AP Davies AG Fernandes JA

We present our experience of the modified Dunn procedure in combination with a Ganz surgical dislocation of the hip to treat patients with severe slipped capital femoral epiphysis (SCFE). The aim was to prospectively investigate whether this technique is safe and reproducible. We assessed the degree of reduction, functional outcome, rate of complications, radiological changes and range of movement in the hip. There were 28 patients with a mean follow-up of 38.6 months (24 to 84). The lateral slip angle was corrected by a mean of 50.9° (95% confidence interval 44.3 to 57.5). The mean modified Harris hip score at the final follow-up was 89.1 (. sd. 9.0) and the mean Non-Arthritic Hip score was 91.3 (. sd. 9.0). Two patients had proven pre-existing avascular necrosis and two developed the condition post-operatively. There were no cases of nonunion, implant failure, infection, deep-vein thrombosis or heterotopic ossification. The range of movement at final follow-up was nearly normal. This study adds to the evidence that the technique of surgical dislocation and anatomical reduction is safe and reliable in patients with SCFE. Cite this article: Bone Joint J 2013;95-B:424–9


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 378 - 385
1 Apr 2019
García-Rey E Carbonell-Escobar R Cordero-Ampuero J García-Cimbrelo E

Aims

We previously reported the long-term results of the cementless Duraloc-Profile total hip arthroplasty (THA) system in a 12- to 15-year follow-up study. In this paper, we provide an update on the clinical and radiological results of a previously reported cohort of patients at 23 to 26 years´ follow-up.

Patients and Methods

Of the 99 original patients (111 hips), 73 patients (82 hips) with a mean age of 56.8 years (21 to 70) were available for clinical and radiological study at a minimum follow-up of 23 years. There were 40 female patients (44 hips) and 33 male patients (38 hips).


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 702 - 707
1 Jun 2019
Moeini S Rasmussen JV Salomonsson B Domeij-Arverud E Fenstad AM Hole R Jensen SL Brorson S

Aims

The aim of this study was to use national registry database information to estimate cumulative rates and relative risk of revision due to infection after reverse shoulder arthroplasty.

Patients and Methods

We included 17 730 primary shoulder arthroplasties recorded between 2004 and 2013 in The Nordic Arthroplasty Register Association (NARA) data set. With the Kaplan–Meier method, we illustrated the ten-year cumulative rates of revision due to infection and with the Cox regression model, we reported the hazard ratios as a measure of the relative risk of revision due to infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 411 - 416
1 May 1984
Kadish L Simmons E

Lumbosacral nerve root anomalies have been documented in the literature for over 30 years; however, no significant quantitative studies have been undertaken so far. We describe parallel studies of 100 cadaveric specimens and an equal number of metrizamide myelograms. The anatomical specimens were prepared by wide deroofing of the lumbar canal to permit precise examination of individual nerve roots and their intradural and extradural connections. The incidence of nerve root anomalies was 14%, the L5-S1 level being most commonly involved. In sharp contrast the incidence of nerve root anomalies determined by myelography was only 4%. The anomalies were classified into four groups and the diagnostic and practical implications of our findings are discussed


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1344 - 1348
1 Oct 2014
Ballal MS Walker CR Molloy AP

We dissected 12 fresh-frozen leg specimens to identify the insertional footprint of each fascicle of the Achilles tendon on the calcaneum in relation to their corresponding muscles. A further ten embalmed specimens were examined to confirm an observation on the retrocalcaneal bursa. The superficial part of the insertion of the Achilles tendon is represented by fascicles from the medial head of the gastrocnemius muscle, which is inserted over the entire width of the inferior facet of the calcaneal tuberosity. In three specimens this insertion was in continuity with the plantar fascia in the form of periosteum. The deep part of the insertion of the Achilles tendon is made of fascicles from the soleus tendon, which insert on the medial aspect of the middle facet of the calcaneal tuberosity, while the fascicles of the lateral head of the gastrocnemius tendon insert on the lateral aspect of the middle facet of the calcaneal tuberosity. A bicameral retrocalcaneal bursa was present in 15 of the 22 examined specimens.

This new observation and description of the insertional footprint of the Achilles tendon and the retrocalcaneal bursa may allow a better understanding of the function of each muscular part of the gastrosoleus complex. This may have clinical relevance in the treatment of Achilles tendinopathies.

Cite this article: Bone Joint J 2014; 96-B:1344–8