Advertisement for orthosearch.org.uk
Results 3681 - 3700 of 6674
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 50 - 56
1 Jan 2008
Muijs SPJ Dijkstra PDS Bos CFA

We performed a retrospective study to assess the long-term outcome of non-augmented anatomical direct repair of the lateral ankle ligaments, as originally described by Duquennoy et al, for the treatment of chronic lateral instability of the ankle. This procedure aims to restore stability by the re-insertion and tightening of the original talofibular and calcaneofibular ligaments without division of the ligament. We examined the outcome in terms of the post-operative quality of life, the function of the joint and the development of osteoarthritis. Between 1985 and 2002, 23 patients (11 males, 12 females) with a mean age of 32 years (15 to 58) who had undergone this procedure completed the Short-Form 36 assessment of quality of life and the Olerud and Molander Ankle score for the subjective evaluation of symptoms. Clinical re-evaluation, including examination of the ankle and the completion of the American Orthopaedic Foot and Ankle Society questionnaire was performed on 21 patients after a mean follow-up of 13 years (3 to 22.2). At the final follow-up radiographs of both ankles were taken to assess the development of osteoarthritis. The mean total Short-Form 36 and Olerud and Molander Ankle scores in 23 patients at final follow-up were 79.6 points (37 to 100) and 81.6 points (40 to 100), respectively. The mean total post-operative American Orthopaedic Foot and Ankle Society score in 21 patients was 89.7 points (72 to 100). We found a significant post-operative reduction in talar tilt and anterior drawer sign (chi-squared test, p < 0.001). The functional outcome of the procedure was excellent in ten patients (48%), good in seven (33%) and fair in four (19%). The results in terms of ankle function and stability did not deteriorate with time and there was little restriction in movement. This procedure is simple and effective with a very low rate of complications


Bone & Joint 360
Vol. 6, Issue 6 | Pages 20 - 22
1 Dec 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 940 - 945
1 Jul 2008
Canavese F Dimeglio A

Children presenting with Perthes’ disease before their sixth birthday are considered to have a good prognosis. We describe 166 hips in children in this age group. The mean age at onset of the disease was 44 months (22 to 72). Mild forms (Catterall I and II) were treated conservatively and severe forms (Catterall III and IV) either conservatively or operatively. The aim of the former treatment was to restrict weight-bearing. Operative treatment consisted of innominate osteotomy and was indicated by a Conway type-B appearance on the bone scan. All the patients were followed to skeletal maturity with a mean follow-up of 11 years (8 to 15). The end results were evaluated radiologically using the classifications of Stulberg and Mose. A total of 50 hips were Catterall grade-I or grade-II, 65 Catterall grade-III and 51 Catterall grade-IV. All hips with mild disease had a good result at skeletal maturity. Of the hips with severe disease 78 (67.3%) had good (Stulberg I and II), 26 (22.4%) fair (Stulberg III) and 12 (10.3%) poor results (Stulberg IV and V). Of the Catterall grade-III hips 38 were treated conservatively of which 31 (81.6%) had a good result, six (15.8%) a fair and one (2.6%) a poor result. Operative treatment was carried out on 27 Catterall grade-III hips, of which 21 (77.8%) had a good, four (14.8%) a fair and two (7.4%) a poor result. By comparison conservative treatment of 19 Catterall grade-IV hips led to ten (52.7%) good, seven (36.8%) fair and two (10.5%) poor results. Operative treatment was carried out on 32 Catterall grade-IV hips, of which 16 (50.0%) had a good, nine (28.1%) a fair and seven (21.9%) a poor result. We confirm that the prognosis in Perthes’ disease is generally good when the age at onset is less than six years. In severe disease there is no significant difference in outcome after conservative or operative treatment (p > 0.05). Catterall grade-III hips had a better outcome according to the Stulberg and Mose criteria than Catterall grade-IV hips, regardless of the method of treatment


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 6 - 10
1 Jan 2018
Lovelock TM Broughton NS

The number of arthroplasties of the hip and knee is predicted to increase rapidly during the next 20 years. Accompanying this is the dilemma of how to follow-up these patients appropriately. Current guidelines recommend long-term follow-up to identify patients with aseptic loosening, which can occur more than a decade postoperatively. The current guidelines and practices of orthopaedic surgeons vary widely. Existing models take up much clinical time and are expensive. Pilot studies using ‘virtual’ clinics and advanced-practice physiotherapists have shown promise in decreasing the time and costs for orthopaedic surgeons and patients.

This review discusses current practices and future trends in the follow-up of patients who have an arthroplasty.

Cite this article: Bone Joint J 2018;100-B:6–10.


Bone & Joint Research
Vol. 1, Issue 12 | Pages 315 - 323
1 Dec 2012
Molt M Ljung P Toksvig-Larsen S

Objectives. The objective of this study was to compare the early migration characteristics and functional outcome of the Triathlon cemented knee prosthesis with its predecessor, the Duracon cemented knee prosthesis (both Stryker). Methods. A total 60 patients were prospectively randomised and tibial component migration was measured by radiostereometric analysis (RSA) at three months, one year and two years; clinical outcome was measured by the American Knee Society score and the Knee Osteoarthritis and Injury Outcome Score. Results. There were no statistically significant differences in rotation or translation around or along the three coordinal axes, or in the maximum total point motion (MTPM) during the two-year follow-up. Conclusions. The Triathlon cemented knee prosthesis has similar early stability and is likely to perform at least as well as the Duracon cemented knee prosthesis over the longer term


Bone & Joint Research
Vol. 2, Issue 8 | Pages 140 - 148
1 Aug 2013
Gauthier L Dinh L Beaulé PE

Objectives. To quantify and compare peri-acetabular bone mineral density (BMD) between a monoblock acetabular component using a metal-on-metal (MoM) bearing and a modular titanium shell with a polyethylene (PE) insert. The secondary outcome was to measure patient-reported clinical function. Methods. A total of 50 patients (25 per group) were randomised to MoM or metal-on-polyethlene (MoP). There were 27 women (11 MoM) and 23 men (14 MoM) with a mean age of 61.6 years (47.7 to 73.2). Measurements of peri-prosthetic acetabular and contralateral hip (covariate) BMD were performed at baseline and at one and two years’ follow-up. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC), University of California, Los Angeles (UCLA) activity score, Harris hip score, and RAND-36 were also completed at these intervals. Results. At two years, only zone 1 showed a loss in BMD (-2.5%) in MoM group compared with a gain in the MoP group (+2.2%). Zone 2 showed loss in both groups (-2.2% for MoM; -3.9% for MoP) and zones 3 and 4 a gain in both groups (+0.1% for MoM; +3.3% for MoP). No other between-group differences were detected. When adjusting for BMD of the contralateral hip, no differences in BMD were observed. The only significant differences in functional scores at two years were higher UCLA activity (7.3 (. sd. 1.2) vs 6.1 (. sd. 1.5); p = 0.01) and RAND-36 physical function (82.1 (. sd. 13.0) vs 64.5 (. sd. 26.4); p = 0.02) for MoM bearings versus MoP. One revision was performed in the MoM group, for aseptic acetabular loosening at 11 months. Conclusions. When controlling for systemic BMD, there were no significant differences between MoM and MoP groups in peri-acetabular BMD. However, increasing reports of adverse tissue reactions with large head MoM THR have restricted the use of the monoblock acetabular component to resurfacing only


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1016 - 1023
1 Aug 2012
Lo SJ Yeo M Puhaindran M Hsu CC Wei FC

The current indications for functional restoration of extension of the knee following quadriceps resection or loss require reappraisal. The contribution of pedicled and free functional muscle transfer is likely to be over-emphasised in many studies, with good functional outcomes predominantly reported only in the context of cases with residual quadriceps function. In cases with total quadriceps resection or loss, all forms of reconstruction perform poorly. Furthermore, in smaller resections with loss of two or fewer components of the quadriceps, minimal impairment of function occurs in the absence of functional reconstruction, suggesting that functional restoration may not be warranted. Thus there is a paradox in the current approach to quadriceps reconstruction, in that small resections are likely to be over-treated and large resections remain under-treated. This review suggests a shift is required in the approach and rationale for reconstructing functional extension of the knee after quadriceps resection or loss. A classification based on current evidence is suggested that emphasises more clearly the indications and rationale for functional transfers


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1571 - 1576
1 Dec 2017
Jacofsky DJ

‘Big data’ is a term for data sets that are so large or complex that traditional data processing applications are inadequate. Billions of dollars have been spent on attempts to build predictive tools from large sets of poorly controlled healthcare metadata. Companies often sell reports at a physician or facility level based on various flawed data sources, and comparative websites of ‘publicly reported data’ purport to educate the public. Physicians should be aware of concerns and pitfalls seen in such data definitions, data clarity, data relevance, data sources and data cleaning when evaluating analytic reports from metadata in health care.

Cite this article: Bone Joint J 2017;99-B:1571–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1148 - 1150
1 Aug 2012
Nakamura Y Ohishi H Kishiya M Toh S

Although good to excellent short-term results of arthroscopic partial limbectomy of the hip have been reported, there is little information on the long-term outcome of the procedure. We report a case with a 16-year follow-up. A 34-year old woman presented with a three-month history of severe pain and limitation of movement of the hip. Plain radiographs and arthrography showed no abnormality. MRI showed an effusion and a deformity of the anterosuperior part of the labrum. This was confirmed as an inverted labral tear that was debrided arthroscopically. At 16 years post-operatively, she remained symptom-free. Plain radiographs showed no abnormality and MRI suggested that the sealing effect of the scar tissue prevented articular damage and degeneration


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 263 - 269
1 Feb 2014
Batta V Coathup MJ Parratt MT Pollock RC Aston WJ Cannon SR Skinner JA Briggs TW Blunn GW

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years. The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial. Cite this article: Bone Joint J 2014;96-B:263–9


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 129 - 132
1 Nov 2013
Berend KR Lombardi Jr AV Adams JB

Debate has raged over whether a cruciate retaining (CR) or a posterior stabilised (PS) total knee replacement (TKR) provides a better range of movement (ROM) for patients. Various sub-sets of CR design are frequently lumped together when comparing outcomes. Additionally, multiple factors have been proven to influence the rate of manipulation under anaesthetic (MUA) following TKR. The purpose of this study was to determine whether different CR bearing insert designs provide better ROM or different MUA rates. All primary TKRs performed by two surgeons between March 2006 and March 2009 were reviewed and 2449 CR-TKRs were identified. The same CR femoral component, instrumentation, and tibial base plate were consistently used. In 1334 TKRs a CR tibial insert with 3° posterior slope and no posterior lip was used (CR-S). In 803 there was an insert with no slope and a small posterior lip (CR-L) and in 312 knees the posterior cruciate ligament (PCL) was either resected or lax and a deep-dish, anterior stabilised insert was used (CR-AS). More CR-AS inserts were used in patients with less pre-operative ROM and greater pre-operative tibiofemoral deformity and flexion contracture (p < 0.05). The mean improvement in ROM was highest for the CR-AS inserts (5.9° (-40° to 55°) vs CR-S 3.1° (-45° to 70°) vs CR-L 3.0° (-45° to 65°); p = 0.004). There was a significantly higher MUA rate with the CR-S and CR-L inserts than CR-AS (Pearson rank 6.51; p = 0.04). Despite sacrificing or not substituting for the PCL, ROM improvement was highest, and the MUA rate was lowest in TKRs with a deep-dish, anterior-stabilised insert. Substitution for the posterior cruciate ligament (PCL) in the form of a PS design may not be necessary even when the PCL is deficient. . Cite this article: Bone Joint J 2013;95-B, Supple A:129–32


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 649 - 656
1 May 2013
Park C Jang J Lee S Lee W

The purpose of this study was to compare the results of proximal and distal chevron osteotomy in patients with moderate hallux valgus. We retrospectively reviewed 34 proximal chevron osteotomies without lateral release (PCO group) and 33 distal chevron osteotomies (DCO group) performed sequentially by a single surgeon. There were no differences between the groups with regard to age, length of follow-up, demographic or radiological parameters. The clinical results were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring system and the radiological results were compared between the groups. At a mean follow-up of 14.6 months (14 to 32) there were no significant differences in the mean AOFAS scores between the DCO and PCO groups (93.9 (82 to 100) and 91.8 (77 to 100), respectively; p = 0.176). The mean hallux valgus angle, intermetatarsal angle and sesamoid position were the same in both groups. The metatarsal declination angle decreased significantly in the PCO group (p = 0.005) and the mean shortening of the first metatarsal was significantly greater in the DCO group (p < 0.001). We conclude that the clinical and radiological outcome after a DCO is comparable with that after a PCO; longer follow-up would be needed to assess the risk of avascular necrosis. Cite this article: Bone Joint J 2013;95-B:649–56


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 127 - 131
1 Jan 2013
Grimer RJ Chandrasekar CR Carter SR Abudu A Tillman RM Jeys L

A total of 157 hindquarter amputations were carried out in our institution during the last 30 years. We have investigated the reasons why this procedure is still required and the outcome. This operation was used as treatment for 13% of all pelvic bone sarcomas. It was curative in 140 and palliative in 17, usually to relieve pain. There were 90 primary procedures (57%) with the remaining 67 following the failure of previous operations to control the disease locally. The indication for amputation in primary disease was for large tumours for which limb-salvage surgery was no longer feasible. The peri-operative mortality was 1.3% (n = 2) and major complications of wound healing or infection arose in 71 (45%) patients. The survival at five years after hindquarter amputation with the intent to cure was 45%, and at ten years 38%. Local recurrence occurred in 23 patients (15%). Phantom pain was a significant problem, and only 20% used their prosthesis regularly. Functional scores were a mean of 57%. With careful patient selection the oncological results and functional outcomes of hindquarter amputation justify its continued use. Cite this article: Bone Joint J 2013;95-B:127–31


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1561 - 1570
1 Dec 2017
Laumonerie P Reina N Kerezoudis P Declaux S Tibbo ME Bonnevialle N Mansat P

Aims

The primary aim of this study was to define the standard minimum follow-up required to produce a reliable estimate of the rate of re-operation after radial head arthroplasty (RHA). The secondary objective was to define the leading reasons for re-operation.

Materials and Methods

Four electronic databases, between January 2000 and March 2017 were searched. Articles reporting reasons for re-operation (Group I) and results (Group II) after RHA were included. In Group I, a meta-analysis was performed to obtain the standard minimum follow-up, the mean time to re-operation and the reason for failure. In Group II, the minimum follow-up for each study was compared with the standard minimum follow-up.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 2 - 10
1 Dec 2017
Luokkala T Watts AC


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1611 - 1617
1 Dec 2017
Frisch NB Courtney PM Darrith B Della Valle CJ

Aims

The purpose of this study is to determine if higher volume hospitals have lower costs in revision hip and knee arthroplasty.

Materials and Methods

We questioned the Centres for Medicare and Medicaid Services (CMS) Inpatient Charge Data and identified 789 hospitals performing a total of 29 580 revision arthroplasties in 2014. Centres were dichotomised into high-volume (performing over 50 revision cases per year) and low-volume. Mean total hospital-specific charges and inpatient payments were obtained from the database and stratified based on Diagnosis Related Group (DRG) codes. Patient satisfaction scores were obtained from the multiyear CMS Hospital Compare database.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1622 - 1626
1 Dec 2005
Hailer NP Soykaner L Ackermann H Rittmeister M

We investigated the variables which determine the outcome after triple osteotomy of the pelvis for the treatment of congenital dysplasia of the hip. We reviewed 51 patients (61 hips) with a median age at operation of 23 years who were treated with a Tönnis triple osteotomy. The median follow-up was six years with a minimum of two years. Eight patients (eight hips) required a revision procedure. Of the remaining 53 hips, the results were good or excellent in 36 (68%) when evaluated according to the Harris hip score (median 90 points), and 33 patients (65%) were satisfied with the procedure. Logistic regression analysis indicated that the incidence of complications such as nonunion at an osteotomy site influenced patient satisfaction (p = 0.079). The incidence of complications correlated positively with increasing patient age at operation (p = 0.004). The amount of acetabular correction did not correlate with patient satisfaction. In univariate analysis, the groups of ’satisfied’ and ‘not satisfied’ patients differed significantly in Harris hip score, age, incidence of nonunion at the osteotomy sites, complications and late revisions. In conclusion, the patient’s age at operation and the incidence of complications influence patient satisfaction after triple osteotomy, but the amount of radiologically evident acetabular correction shows no correlation to outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 297 - 301
1 Mar 2012
Haddad FS Konan S

An international faculty of orthopaedic surgeons presented their work on the current challenges in hip surgery at the London Hip Meeting which was attended by over 400 delegates. The topics covered included femoroacetabular impingement, thromboembolic phenomena associated with hip surgery, bearing surfaces (including metal-on-metal articulations), outcomes of hip replacement surgery and revision hip replacement. We present a concise report of the current opinions on hip surgery from this meeting with appropriate references to the current literature


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 181 - 187
1 Feb 2013
Liddle AD Pandit H O’Brien S Doran E Penny ID Hooper GJ Burn PJ Dodd CAF Beverland DE Maxwell AR Murray DW

The Cementless Oxford Unicompartmental Knee Replacement (OUKR) was developed to address problems related to cementation, and has been demonstrated in a randomised study to have similar clinical outcomes with fewer radiolucencies than observed with the cemented device. However, before its widespread use it is necessary to clarify contraindications and assess the complications. This requires a larger study than any previously published. We present a prospective multicentre series of 1000 cementless OUKRs in 881 patients at a minimum follow-up of one year. All patients had radiological assessment aligned to the bone–implant interfaces and clinical scores. Analysis was performed at a mean of 38.2 months (19 to 88) following surgery. A total of 17 patients died (comprising 19 knees (1.9%)), none as a result of surgery; there were no tibial or femoral loosenings. A total of 19 knees (1.9%) had significant implant-related complications or required revision. Implant survival at six years was 97.2%, and there was a partial radiolucency at the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies. There was no significant increase in complication rate compared with cemented fixation (p = 0.87), and no specific contraindications to cementless fixation were identified. Cementless OUKR appears to be safe and reproducible in patients with end-stage anteromedial osteoarthritis of the knee, with radiological evidence of improved fixation compared with previous reports using cemented fixation. Cite this article: Bone Joint J 2013;95-B:181–7


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 109 - 118
1 Jan 2018
Talbot C Davis N Majid I Young M Bouamra O Lecky FE Jones S

Aims

The aim of this study was to describe the epidemiology of closed isolated fractures of the femoral shaft in children, and to compare the treatment and length of stay (LOS) between major trauma centres (MTCs) and trauma units (TUs) in England.

Patients and Methods

National data were obtained from the Trauma and Audit Research Network for all isolated, closed fractures of the femoral shaft in children from birth to 15 years of age, between 2012 and 2015. Age, gender, the season in which the fracture occurred, non-accidental injury, the mechanism of injury, hospital trauma status, LOS and type of treatment were recorded.