header advert
Results 301 - 320 of 713
Results per page:
Bone & Joint 360
Vol. 8, Issue 3 | Pages 23 - 26
1 Jun 2019


Bone & Joint 360
Vol. 9, Issue 1 | Pages 53 - 53
1 Feb 2020


Bone & Joint 360
Vol. 8, Issue 5 | Pages 21 - 24
1 Oct 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 696 - 700
1 Jul 2004
Harvie P Ostlere SJ Teh J McNally EG Clipsham K Burston BJ Pollard TCB Carr AJ

From a retrospective, cohort study of 205 patients diagnosed with full-thickness tears of the rotator cuff, we determined, using ultrasound, the prevalence of such tears in their 129 siblings. Using 150 spouses as controls, the relative risk of full-thickness tears in siblings versus controls was 2.42 (95% CI 1.77 to 3.31). The relative risk of symptomatic full-thickness tears in siblings versus controls was 4.65 (95% CI 2.42 to 8.63). The significantly increased risk for tears in siblings implies that genetic factors play a major role in the development of full-thickness tears of the rotator cuff


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 236 - 237
1 Mar 2019
Perry DC Paton RW


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 890 - 892
1 Sep 1999
Rickman M Saleh M Gaines PA Eyres K

Osteotomies are commonly carried out in orthopaedic surgery, particularly in limb reconstruction. Complications are uncommon provided that sufficient care is taken and a sound technique used. We describe three cases of formation of false aneurysm after osteotomy, with acute, delayed and asymptomatic onset. The diagnosis was supported by ultrasound investigation, and confirmed by angiography. Embolisation with coils was a successful method of treatment. We recommend a safe method of osteotomy with good bone exposure and adequate soft-tissue protection


Bone & Joint 360
Vol. 9, Issue 1 | Pages 4 - 9
1 Feb 2020
Logishetty K Muirhead-Allwood SK Cobb JP


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1385 - 1391
1 Oct 2019
Nicholson JA Gribbin H Clement ND Robinson CM

Aims

The primary aim of this study was to determine if delayed clavicular fixation results in a greater risk of operative complications and revision surgery.

Patients and Methods

A retrospective case series was undertaken of all displaced clavicular fractures that underwent plate fixation over a ten-year period (2007 to 2017). Patient demographics, time to surgery, complications, and mode of failure were collected. Logistic regression was used to identify independent risk factors contributing towards operative complications. Receiver operating characteristic (ROC) curve analysis was used to determine if a potential ‘safe window’ exists from injury to delayed surgery. Propensity score matching was used to construct a case control study for comparison of risk.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 204 - 205
1 Mar 2001
Thomas RH Holt MD James SH White PG

The imaging techniques available to aid the diagnosis of ruptures of tendo Achillis, the rotator cuff and the tendon of tibialis posterior in rheumatoid patients are well described. However, ruptures of tendon or muscle at other sites are uncommon and may be overlooked. Diagnosis is often made by localised tenderness, swelling and a lack of active movement associated with a palpable defect. Clinical examination may be inconclusive and can be aided by imaging studies. We report two cases in which ruptures of a tendon were suspected, and ultrasound imaging demonstrated the palpable defect to be a cleavage plane in the subcutaneous fat – a ‘fat fracture’


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 479 - 482
1 May 1993
Dias J Thomas I Lamont A Mody B Thompson

Ultrasound scans were made of the hips of 209 neonates born consecutively over a two-week period. Of the 418 scans, 62 images were selected at random and 25 of these were duplicated to give a total of 87 scans. These static images were then presented to five experienced observers who each made nine different assessments and measurements. Interobserver and intraboserver agreement was calculated and expressed as kappa values. Our results showed poor reliability on both counts


Bone & Joint 360
Vol. 9, Issue 1 | Pages 44 - 47
1 Feb 2020


Bone & Joint 360
Vol. 9, Issue 1 | Pages 28 - 32
1 Feb 2020


Bone & Joint 360
Vol. 8, Issue 3 | Pages 26 - 29
1 Jun 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1037 - 1040
1 Sep 2001
Eisele R Weickert E Eren A Kinzl L

We studied the effect of full and partial weight-bearing on venous peak velocity in the legs of 73 subjects. We used colourflow Duplex ultrasound to determine the minimal amount of weight-bearing required to produce the same venous peak velocity as full weight-bearing. We found that the venous peak velocity remains the same in the femoral vein during partial weight-bearing (196 N and above). This is important for postoperative physiotherapy and thrombo-prophylaxis. The median peak velocity was 30 cm/s. This corresponds to an amplification factor of four in relation to the individual resting level (peak velocity). In addition, we found that partial weight-bearing at 196 N can reliably be reproduced. The median value of partial weight-bearing after a three-day training programme was 206 N


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1100 - 1106
1 Sep 2019
Schemitsch C Chahal J Vicente M Nowak L Flurin P Lambers Heerspink F Henry P Nauth A

Aims

The purpose of this study was to compare the effectiveness of surgical repair to conservative treatment and subacromial decompression for the treatment of chronic/degenerative tears of the rotator cuff.

Materials and Methods

PubMed, Cochrane database, and Medline were searched for randomized controlled trials published until March 2018. Included studies were assessed for methodological quality, and data were extracted for statistical analysis. The systematic review was conducted following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 132 - 136
1 Jan 2020
Hommel H Becker R Fennema P Kopf S

Aims

We report the natural course of Baker’s cysts following total knee arthroplasty (TKA) at short- and mid-term follow-up.

Methods

In this prospective case series, 105 TKA patients were included. All patients who received surgery had a diagnosis of primary osteoarthritis and had preoperatively presented with a Baker’s cyst. Sonography and MRI were performed to evaluate the existence and the gross size of the cyst before TKA, and sonography was repeated at a mean follow-up time of 1.0 years (0.8 to 1.3; short-term) and 4.9 years (4.0 to 5.6; mid-term) after TKA. Symptoms potentially attributable to the Baker’s cyst were recorded at each assessment.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 683 - 685
1 Jul 1991
Weinstabl R Stiskal M Neuhold A Aamlid B Hertz H

Magnetic resonance imaging was performed on 28 patients with suspected calcaneal tendon injury prior to treatment. None of the patients were involved in competitive sports. All underwent clinical examination, some had had ultrasound or CT scans. We identified four types of lesions: type I, inflammatory reaction; type II, degenerative change; type III, incomplete rupture and type IV, complete rupture. Thirteen of the 28 patients underwent surgery and the diagnostic findings were verified. We recommend that type I, type II and type III lesions be managed conservatively, while type IV lesions should be operated in the young and active patient


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 100 - 103
1 Jan 2002
Saifuddin A Heffernan G Birch R

Ultrasound (US) was used to determine the congruity of the shoulder in 22 children with a deformity of the shoulder secondary to chronic obstetric brachial plexus palsy. There were 11 boys and 11 girls with a mean age of 4.75 years (0.83 to 13.92). The shoulder was scanned in the axial plane using a posterior approach with the arm internally rotated. The humeral head was classified as being either congruent or incongruent. The US appearance was compared with that on clinical examination and related to the intraoperative findings. All 17 shoulders diagnosed as incongruent on US were found to be incongruent at operation, whereas three diagnosed as congruent by US were found to be incongruent at operation. The diagnostic accuracy of US for the identification of shoulder incongruity was 82% when compared with the findings at surgery. US is a valuable, but not infallible tool, for the detection of incongruity of the shoulder


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 588 - 591
1 Jul 1994
Skirving A Kozak T Davis S

We describe five patients, seen since 1984, with posterior shoulder pain and isolated wasting and weakness of the infraspinatus. In four of these a ganglion in the spinoglenoid notch was demonstrated by MRI and in one recent case ultrasound scans were positive. Three patients have been treated by operation, but there was recurrence in one after five years. In each confirmed case, the ganglion straddled the base of the spine of the scapula, extending into both supraspinatus and infraspinatus fossae. The nerve was either compressed against the spine or stretched over the posterior aspect of the ganglion. Adequate surgical exposure is essential to preserve the nerve to the infraspinatus and to allow complete removal of the ganglion. This is difficult because of the location and thin-walled nature of the cysts


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 422 - 427
1 May 1997
Wallace AL Walsh WR van Rooijen M Hughes JS Sonnabend DH

In severe forearm injuries, the diagnosis of disruption of the interosseous membrane is frequently delayed and sometimes missed, giving difficulties in the salvage of forearm stability. We studied the structure and function of the interosseous membrane in 11 cadaver preparations, using mechanical and histological analysis. Seven of the specimens tested in uniaxial tension sustained a mid-substance tear of the central band of the membrane at a mean peak load of 1038 ± 308 N. The axial stiffness was 190 ± 44 N/mm with elongation to failure of 10.34 ± 2.46 mm. These results provide criteria for the evaluation of reconstructive methods. A preliminary clinical investigation of the use of ultrasound suggests that this may be of value in the screening of patients with complex fractures of the forearm, and for investigating the natural history of tears of the interosseous membrane