Advertisement for orthosearch.org.uk
Results 301 - 320 of 1250
Results per page:
Bone & Joint Open
Vol. 2, Issue 10 | Pages 796 - 805
1 Oct 2021
Plumarom Y Wilkinson BG Willey MC An Q Marsh L Karam MD

Aims

The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing.

Methods

A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1754 - 1758
1 Dec 2021
Farrow L Zhong M Ashcroft GP Anderson L Meek RMD

There is increasing popularity in the use of artificial intelligence and machine-learning techniques to provide diagnostic and prognostic models for various aspects of Trauma & Orthopaedic surgery. However, correct interpretation of these models is difficult for those without specific knowledge of computing or health data science methodology. Lack of current reporting standards leads to the potential for significant heterogeneity in the design and quality of published studies. We provide an overview of machine-learning techniques for the lay individual, including key terminology and best practice reporting guidelines.

Cite this article: Bone Joint J 2021;103-B(12):1754–1758.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1586 - 1594
1 Oct 2021
Sharma N Rehmatullah N Kuiper JH Gallacher P Barnett AJ

Aims

The Oswestry-Bristol Classification (OBC) is an MRI-specific assessment tool to grade trochlear dysplasia. The aim of this study is to validate clinically the OBC by demonstrating its use in selecting treatments that are safe and effective.

Methods

The OBC and the patellotrochlear index were used as part of the Oswestry Patellotrochlear Algorithm (OPTA) to guide the surgical treatment of patients with patellar instability. Patients were assigned to one of four treatment groups: medial patellofemoral ligament reconstruction (MPFLr); MPFLr + tibial tubercle distalization (TTD); trochleoplasty; or trochleoplasty + TTD. A prospective analysis of a longitudinal patellofemoral database was performed. Between 2012 and 2018, 202 patients (233 knees) with a mean age of 24.2 years (SD 8.1), with recurrent patellar instability were treated by two fellowship-trained consultant sports/knee surgeons at The Robert Jones and Agnes Hunt Orthopaedic Hospital. Clinical efficacy of each treatment group was assessed by Kujala, International Knee Documentation Committee (IKDC), and EuroQol five-dimension questionnaire (EQ-5D) scores at baseline, and up to 60 months postoperatively. Their safety was assessed by complication rate and requirement for further surgery. The pattern of clinical outcome over time was analyzed using mixed regression modelling.


Bone & Joint Research
Vol. 11, Issue 4 | Pages 239 - 250
20 Apr 2022
Stewart CC O’Hara NN Bzovsky S Bahney CS Sprague S Slobogean GP

Aims

Bone turnover markers (BTMs) follow distinct trends after fractures and limited evidence suggests differential levels in BTMs in patients with delayed healing. The effect of vitamin D, and other factors that influence BTMs and fracture healing, is important to elucidate the use of BTMs as surrogates of fracture healing. We sought to determine whether BTMs can be used as early markers of delayed fracture healing, and the effect of vitamin D on BTM response after fracture.

Methods

A total of 102 participants aged 18 to 50 years (median 28 years (interquartile range 23 to 35)), receiving an intramedullary nail for a tibial or femoral shaft fracture, were enrolled in a randomized controlled trial comparing vitamin D3 supplementation to placebo. Serum C-terminal telopeptide of type I collagen (CTX; bone resorption marker) and N-terminal propeptide of type I procollagen (P1NP; bone formation marker) were measured at baseline, six weeks, and 12 weeks post-injury. Clinical and radiological fracture healing was assessed at three months.


Bone & Joint Research
Vol. 11, Issue 4 | Pages 189 - 199
13 Apr 2022
Yang Y Li Y Pan Q Bai S Wang H Pan X Ling K Li G

Aims

Treatment for delayed wound healing resulting from peripheral vascular diseases and diabetic foot ulcers remains a challenge. A novel surgical technique named ‘tibial cortex transverse transport’ (TTT) has been developed for treating peripheral ischaemia, with encouraging clinical effects. However, its underlying mechanisms remain unclear. In the present study, we explored the potential biological mechanisms of TTT surgery using various techniques in a rat TTT animal model.

Methods

A novel rat model of TTT was established with a designed external fixator, and effects on wound healing were investigated. Laser speckle perfusion imaging, vessel perfusion, histology, and immunohistochemistry were used to evaluate the wound healing processes.


Bone & Joint 360
Vol. 11, Issue 2 | Pages 27 - 30
1 Apr 2022


Bone & Joint Open
Vol. 3, Issue 1 | Pages 98 - 106
27 Jan 2022
Gelfer Y Leo DG Russell A Bridgens A Perry DC Eastwood DM

Aims

To identify the minimum set of outcomes that should be collected in clinical practice and reported in research related to the care of children with idiopathic congenital talipes equinovarus (CTEV).

Methods

A list of outcome measurement tools (OMTs) was obtained from the literature through a systematic review. Further outcomes were collected from patients and families through a questionnaire and interview process. The combined list, as well as the appropriate follow-up timepoint, was rated for importance in a two-round Delphi process that included an international group of orthopaedic surgeons, physiotherapists, nurse practitioners, patients, and families. Outcomes that reached no consensus during the Delphi process were further discussed and scored for inclusion/exclusion in a final consensus meeting involving international stakeholder representatives of practitioners, families, and patient charities.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1124 - 1129
1 Aug 2014
Segaren N Abdul-Jabar HB Hashemi-Nejad A

Proximal femoral varus osteotomy improves the biomechanics of the hip and can stimulate normal acetabular development in a dysplastic hip. Medial closing wedge osteotomy remains the most popular technique, but is associated with shortening of the ipsilateral femur. We produced a trigonometric formula which may be used pre-operatively to predict the resultant leg length discrepancy (LLD). We retrospectively examined the influence of the choice of angle in a closing wedge femoral osteotomy on LLD in 120 patients (135 osteotomies, 53% male, mean age six years, (3 to 21), 96% caucasian) over a 15-year period (1998 to 2013). A total of 16 of these patients were excluded due to under or over varus correction. The patients were divided into three age groups: paediatric (< 10 years), adolescent (10 to 16 years) and adult (> 16 years). When using the same saw blades as in this series, the results indicated that for each 10° of angle of resection the resultant LLD equates approximately to multiples of 4 mm, 8 mm and 12 mm in the three age groups, respectively. Statistical testing of the 59 patients who had a complete set of pre- and post-operative standing long leg radiographs, revealed a Pearson’s correlation coefficient for predicted versus radiologically observed shortening when using a wedge of either 10° or 20° of 0.93 (p <  0.001). The 95% limits of agreement from the Bland–Altman analysis for this subgroup were –3.5 mm to +3.3 mm. It has been accepted that a 10 mm discrepancy is clinically acceptable. This study identified a geometric model that provided satisfactory accuracy when using specific saw blades of known thicknesses for this formula to be used in clinical practice. Cite this article: Bone Joint J 2014;96-B:1124–9


Bone & Joint Open
Vol. 3, Issue 4 | Pages 321 - 331
8 Apr 2022
Dean BJF Srikesavan C Horton R Toye F

Aims

Osteoarthritis (OA) affecting the thumb carpometacarpal joint (CMCJ) is a common painful condition. In this study, we aimed to explore clinicians’ approach to management with a particular focus on the role of specific interventions that will inform the design of future clinical trials.

Methods

We interviewed a purposive sample of 24 clinicians, consisting of 12 surgeons and 12 therapists (four occupational therapists and eight physiotherapists) who managed patients with CMCJ OA. This is a qualitative study using semi-structured, online interviews. Interviews were audio-recorded, transcribed verbatim, and analyzed using thematic analysis.


Bone & Joint Open
Vol. 3, Issue 3 | Pages 268 - 274
21 Mar 2022
Krishnan H Eldridge JD Clark D Metcalfe AJ Stevens JM Mandalia V

Recognized anatomic variations that lead to patella instability include patella alta and trochlea dysplasia. Lateralization of the extensor mechanism relative to the trochlea is often considered to be a contributing factor; however, controversy remains as to the degree this contributes to instability and how this should be measured. As the tibial tuberosity-trochlear groove (TT-TG) is one of most common imaging measurements to assess lateralization of the extensor mechanism, it is important to understand its strengths and weaknesses. Care needs to be taken while interpreting the TT-TG value as it is affected by many factors. Medializing tibial tubercle osteotomy is sometimes used to correct the TT-TG, but may not truly address the underlying anatomical problem. This review set out to determine whether the TT-TG distance sufficiently summarizes the pathoanatomy, and if this assists with planning of surgery in patellar instability.

Cite this article: Bone Jt Open 2022;3(3):268–274.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 614 - 615
1 Aug 1986
Christensen F Soballe K Ejsted R Luxhoj T

The reliability of the Catterall grouping of Perthes' disease was examined by determining the agreement between pairs of observers using weighted kappa statistics. Anteroposterior and lateral radiographs of 100 hip joints were grouped independently by four experienced observers. There was a low, and in our opinion, unacceptable degree of inter-observer agreement even when Groups 2 and 3 were combined


Bone & Joint Open
Vol. 3, Issue 3 | Pages 245 - 251
16 Mar 2022
Lester D Barber C Sowers CB Cyrus JW Vap AR Golladay GJ Patel NK

Aims

Return to sport following undergoing total (TKA) and unicompartmental knee arthroplasty (UKA) has been researched with meta-analyses and systematic reviews of varying quality. The aim of this study is to create an umbrella review to consolidate the data into consensus guidelines for returning to sports following TKA and UKA.

Methods

Systematic reviews and meta-analyses written between 2010 and 2020 were systematically searched. Studies were independently screened by two reviewers and methodology quality was assessed. Variables for analysis included objective classification of which sports are safe to participate in postoperatively, time to return to sport, prognostic indicators of returning, and reasons patients do not.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 495 - 503
1 Apr 2022
Wong LPK Cheung PWH Cheung JPY

Aims

The aim of this study was to assess the ability of morphological spinal parameters to predict the outcome of bracing in patients with adolescent idiopathic scoliosis (AIS) and to establish a novel supine correction index (SCI) for guiding bracing treatment.

Methods

Patients with AIS to be treated by bracing were prospectively recruited between December 2016 and 2018, and were followed until brace removal. In all, 207 patients with a mean age at recruitment of 12.8 years (SD 1.2) were enrolled. Cobb angles, supine flexibility, and the rate of in-brace correction were measured and used to predict curve progression at the end of follow-up. The SCI was defined as the ratio between correction rate and flexibility. Receiver operating characteristic (ROC) curve analysis was carried out to assess the optimal thresholds for flexibility, correction rate, and SCI in predicting a higher risk of progression, defined by a change in Cobb angle of ≥ 5° or the need for surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific


Bone & Joint Open
Vol. 3, Issue 1 | Pages 20 - 28
10 Jan 2022
Fujii H Hayama T Abe T Takahashi M Amagami A Matsushita Y Otani T Saito M

Aims

Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population.

Methods

This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either radiolucent lines (RLLs), cortical hypertrophy (CH), or atrophy (AT) appeared or not on the one-year radiograph. Further, three-year radiographs of eligible cases were reviewed to determine changes such as, disappeared (D), improved (I), stable (S), and progression (P). Additionally, bone condensation (BC) was assessed on the three-year radiograph.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 639 - 649
19 Oct 2021
Bergiers S Hothi H Henckel J Di Laura A Belzunce M Skinner J Hart A

Aims

Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning.

Methods

3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham hip replacements (BHRs) allowed the co-registration of their acetabular wear maps and their computational models, segmented from CT scans. The in vivo location of edge-wear was measured within a standardized coordinate system, defined using the anterior pelvic plane.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1209 - 1215
1 Sep 2012
Murakami AM Hash TW Hepinstall MS Lyman S Nestor BJ Potter HG

Component malalignment can be associated with pain following total knee replacement (TKR). Using MRI, we reviewed 50 patients with painful TKRs and compared them with a group of 16 asymptomatic controls to determine the feasibility of using MRI in evaluating the rotational alignment of the components. Using the additional soft-tissue detail provided by this modality, we also evaluated the extent of synovitis within these two groups. Angular measurements were based on the femoral transepicondylar axis and tibial tubercle. Between two observers, there was very high interobserver agreement in the measurements of all values. Patients with painful TKRs demonstrated statistically significant relative internal rotation of the femoral component (p = 0.030). There was relative internal rotation of the tibial to femoral component and combined excessive internal rotation of the components in symptomatic knees, although these results were significant only with one of the observers (p = 0.031). There was a statistically significant association between the presence and severity of synovitis and painful TKR (p < 0.001). MRI is an effective modality in evaluating component rotational alignment


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 306 - 311
1 Mar 2015
Weber M Lechler P von Kunow F Völlner F Keshmiri A Hapfelmeier A Grifka J Renkawitz T

Femoral stem version has a major influence on impingement and early post-operative stability after total hip arthroplasty (THA). The main objective of this study was to evaluate the validity of a novel radiological method for measuring stem version. Anteroposterior (AP) radiographs and three-dimensional CT scans were obtained for 115 patients (female/male 63/72, mean age 62.5 years (50 to 75)) who had undergone minimally invasive, cementless THA. Stem version was calculated from the AP hip radiograph by rotation-based change in the projected prosthetic neck–shaft (NSA*) angle using the mathematical formula ST = arcos [tan (NSA*) / tan (135)]. We used two independent observers who repeated the analysis after a six-week interval. Radiological measurements were compared with 3D-CT measurements by an independent, blinded external institute. We found a mean difference of 1.2° (. sd. 6.2) between radiological and 3D-CT measurements of stem version. The correlation between the mean radiological and 3D-CT stem torsion was r = 0.88 (p < 0.001). The intra- (intraclass correlation coefficient ≥ 0.94) and inter-observer agreement (mean concordance correlation coefficient = 0.87) for the radiological measurements were excellent. We found that femoral tilt was associated with the mean radiological measurement error (r = 0.22, p = 0.02). . The projected neck–shaft angle is a reliable method for measuring stem version on AP radiographs of the hip after a THA. However, a highly standardised radiological technique is required for its precise measurement. . Cite this article: Bone Joint J 2015; 97-B:306–11


Bone & Joint Open
Vol. 2, Issue 10 | Pages 865 - 870
20 Oct 2021
Wignadasan W Mohamed A Kayani B Magan A Plastow R Haddad FS

Aims

The COVID-19 pandemic drastically affected elective orthopaedic services globally as routine orthopaedic activity was largely halted to combat this global threat. Our institution (University College London Hospital, UK) previously showed that during the first peak, a large proportion of patients were hesitant to be listed for their elective lower limb procedure. The aim of this study is to assess if there is a patient perception change towards having elective surgery now that we have passed the peak of the second wave of the pandemic.

Methods

This is a prospective study of 100 patients who were on the waiting list of a single surgeon for an elective hip or knee procedure. Baseline characteristics including age, American Society of Anesthesiologists (ASA) grade, COVID-19 risk, procedure type, and admission type were recorded. The primary outcome was patient consent to continue with their scheduled surgical procedure. Subgroup analysis was also conducted to define if any specific patient factors influenced decision to continue with surgery


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 311 - 320
1 Mar 2022
Cheok T Smith T Siddiquee S Jennings MP Jayasekera N Jaarsma RL

Aims

The preoperative diagnosis of periprosthetic joint infection (PJI) remains a challenge due to a lack of biomarkers that are both sensitive and specific. We investigated the performance characteristics of polymerase chain reaction (PCR), interleukin-6 (IL6), and calprotectin of synovial fluid in the diagnosis of PJI.

Methods

We performed systematic search of PubMed, Embase, The Cochrane Library, Web of Science, and Science Direct from the date of inception of each database through to 31 May 2021. Studies which described the diagnostic accuracy of synovial fluid PCR, IL6, and calprotectin using the Musculoskeletal Infection Society criteria as the reference standard were identified.