Advertisement for orthosearch.org.uk
Results 241 - 260 of 776
Results per page:
Bone & Joint Open
Vol. 2, Issue 5 | Pages 330 - 336
21 May 2021
Balakumar B Nandra RS Woffenden H Atkin B Mahmood A Cooper G Cooper J Hindle P

Aims

It is imperative to understand the risks of operating on urgent cases during the COVID-19 (SARS-Cov-2 virus) pandemic for clinical decision-making and medical resource planning. The primary aim was to determine the mortality risk and associated variables when operating on urgent cases during the COVID-19 pandemic. The secondary objective was to assess differences in the outcome of patients treated between sites treating COVID-19 and a separate surgical site.

Methods

The primary outcome measure was 30-day mortality. Secondary measures included complications of surgery, COVID-19 infection, and length of stay. Multiple variables were assessed for their contribution to the 30-day mortality. In total, 433 patients were included with a mean age of 65 years; 45% were male, and 90% were Caucasian.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 629 - 638
20 Oct 2021
Hayashi S Hashimoto S Kuroda Y Nakano N Matsumoto T Ishida K Shibanuma N Kuroda R

Aims

This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH).

Methods

The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims

This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty.

Methods

Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 265 - 269
1 Feb 2012
Hwang N Grimer RJ Carter SR Tillman RM Abudu A Jeys LM

We reviewed our initial seven-year experience with a non-invasive extendible prosthesis in 34 children with primary bone tumours. The distal femur was replaced in 25 cases, total femur in five, proximal femur in one and proximal tibia in three. The mean follow-up was 44 months (15 to 86) and 27 patients (79%) remain alive. The prostheses were lengthened by an electromagnetic induction mechanism in an outpatient setting and a mean extension of 32 mm (4 to 80) was achieved without anaesthesia. There were lengthening complications in two children: failed lengthening in one and the formation of scar tissue in the other. Deep infection developed in six patients (18%) and local recurrence in three. A total of 11 patients required further surgery to the leg. Amputation was necessary in five patients (20%) and a two-stage revision in another. There were no cases of loosening, but two patients had implant breakage and required revision. The mean Musculoskeletal Tumor Society functional score was 85% (60% to 100%) at last known follow-up. These early results demonstrate that the non-invasive extendible prosthesis allows successful lengthening without surgical intervention, but the high incidence of infection is a cause for concern


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1206 - 1214
1 Jul 2021
Tsikandylakis G Mortensen KRL Gromov K Mohaddes M Malchau H Troelsen A

Aims

We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty.

Methods

In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 984 - 990
1 May 2021
Laitinen MK Evans S Stevenson J Sumathi V Kask G Jeys LM Parry MC

Aims

Chondrosarcoma is the second most common primary sarcoma of bone: conventional chondrosarcoma accounts for 85% of all cases. Conventional chondrosarcoma may be central or peripheral. Most studies group central and peripheral chondrosarcomas together, although there is growing evidence that their clinical behaviour and prognosis differ. The aims of this study were to analyze any differences in characteristics between central and peripheral chondrosarcomas and to investigate the incidence and role of different syndromes.

Methods

Data from two international tertiary referral sarcoma centres between January 1995 and December 2018 were retrospectively reviewed. The study population consisted of 714 patients with surgically treated conventional chondrosarcoma of the pelvis and limbs.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 813 - 824
7 Oct 2021
Lerch TD Boschung A Schmaranzer F Todorski IAS Vanlommel J Siebenrock KA Steppacher SD Tannast M

Aims

The effect of pelvic tilt (PT) and sagittal balance in hips with pincer-type femoroacetabular impingement (FAI) with acetabular retroversion (AR) is controversial. It is unclear if patients with AR have a rotational abnormality of the iliac wing. Therefore, we asked: are parameters for sagittal balance, and is rotation of the iliac wing, different in patients with AR compared to a control group?; and is there a correlation between iliac rotation and acetabular version?

Methods

A retrospective, review board-approved, controlled study was performed including 120 hips in 86 consecutive patients with symptomatic FAI or hip dysplasia. Pelvic CT scans were reviewed to calculate parameters for sagittal balance (pelvic incidence (PI), PT, and sacral slope), anterior pelvic plane angle, pelvic inclination, and external rotation of the iliac wing and were compared to a control group (48 hips). The 120 hips were allocated to the following groups: AR (41 hips), hip dysplasia (47 hips) and cam FAI with normal acetabular morphology (32 hips). Subgroups of total AR (15 hips) and high acetabular anteversion (20 hips) were analyzed. Statistical analysis was performed using analysis of variance with Bonferroni correction.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1497 - 1504
1 Sep 2021
Rotman D Ariel G Rojas Lievano J Schermann H Trabelsi N Salai M Yosibash Z Sternheim A

Aims

Type 2 diabetes mellitus (T2DM) impairs bone strength and is a significant risk factor for hip fracture, yet currently there is no reliable tool to assess this risk. Most risk stratification methods rely on bone mineral density, which is not impaired by diabetes, rendering current tests ineffective. CT-based finite element analysis (CTFEA) calculates the mechanical response of bone to load and uses the yield strain, which is reduced in T2DM patients, to measure bone strength. The purpose of this feasibility study was to examine whether CTFEA could be used to assess the hip fracture risk for T2DM patients.

Methods

A retrospective cohort study was undertaken using autonomous CTFEA performed on existing abdominal or pelvic CT data comparing two groups of T2DM patients: a study group of 27 patients who had sustained a hip fracture within the year following the CT scan and a control group of 24 patients who did not have a hip fracture within one year. The main outcome of the CTFEA is a novel measure of hip bone strength termed the Hip Strength Score (HSS).


Bone & Joint Research
Vol. 10, Issue 4 | Pages 250 - 258
1 Apr 2021
Kwak D Bang S Lee S Park J Yoo J

Aims

There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning.

Methods

In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 952 - 956
1 Jul 2008
Haddad F Chemali R Maalouf G

Dysplasia epiphysealis hemimelica of the left proximal femur was diagnosed in an eight-month-old girl. At the age of 18 months, radiographs of the hip and MRI showed overgrowth and loss of containment of the femoral head. She underwent resection of the superior portion of the head and neck of the femur at the age of 2.5 years. Six months later further radiographs and an MR scan show that the mass has increased in size and that hip containment has been lost. Further plain radiographs have shown that the left knee, ankle and spine were involved. To the authors’ knowledge, this is the first report of dysplasia epiphysealis hemimelica involving both the lower limb and the spine. A review of the literature is presented


Bone & Joint Open
Vol. 2, Issue 8 | Pages 611 - 617
10 Aug 2021
Kubik JF Bornes TD Klinger CE Dyke JP Helfet DL

Aims

Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck.

Methods

A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 38 - 40
1 Jan 1984
Bago-Granell J Aguirre-Canyadell M Nardi J Tallada N

A patient who presented with a malignant fibrous histiocytoma in the proximal femur after a total hip replacement is reported. The arthroplasty was of the Charnley-Muller type with detachment of the greater trochanter; polymethylmethacrylate cement was used. The possible tumour-forming effect of implant materials is discussed and the literature reviewed


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 999 - 1004
1 May 2021
Pollet V Bonsel J Ganzeboom B Sakkers R Waarsing E

Aims

The most important complication of treatment of developmental dysplasia of the hip (DDH) is avascular necrosis (AVN) of the femoral head, which can result in proximal femoral growth disturbances leading to pain, dysfunction, and eventually to early onset osteoarthritis. In this study, we aimed to identify morphological variants in hip joint development that are predictive of a poor outcome.

Methods

We retrospectively reviewed all patients who developed AVN after DDH treatment, either by closed and/or open reduction, at a single institution between 1984 and 2007 with a minimal follow-up of eight years. Standard pelvis radiographs obtained at ages one, two, three, five, and eight years, and at latest follow-up were retrieved. The Bucholz-Ogden classification was used to determine the type of AVN on all radiographs. Poor outcome was defined by Severin classification grade 3 or above on the latest follow-up radiographs and/or the need for secondary surgery. With statistical shape modelling, we identified the different shape variants of the hip at each age. Logistic regression analysis was used to associate the different modes or shape variants with poor outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 558 - 564
1 Aug 1987
Weightman B Freeman M Revell P Braden M Albrektsson B Carlson L

Mechanical and biomechanical testing of a new bone cement suggests that improved load transfer to the proximal femur could be achieved with the combination of a cement having a lower modulus, a greater ductility and a lower creep resistance than polymethylmethacrylate and a suitably shaped femoral component


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 643 - 646
1 Jul 1990
Mulroy R Mankin H Harris W

We describe a patient in whom a total hip replacement had failed and who subsequently fractured her proximal femur. The prosthetic hip and the surrounding bone were excised and replaced by a matched pair of allograft components. She obtained seven years of pain free hip function before the graft showed radiographic signs of failure; it was then replaced by a new prosthetic hip


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 441 - 444
1 May 1993
Anderson G Raymakers R Gregg P

We have studied the incidence of fractures of the proximal femur in one English county from 1968 to 1991. Numbers have increased steadily, but the age-specific incidence has remained relatively unchanged since 1981. The increase is due to the rise in the population most at risk; this is likely to continue causing a 20% increase in demand for treatment by the year 2000. Suitable allocation of resources must be planned


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1182 - 1188
1 Nov 2000
Barker DS Wang AW Yeo MF Nawana NS Brumby SA Pearcy MJ Howie DW

We studied the effect of the surface finish of the stem on the transfer of load in the proximal femur in a sheep model of cemented hip arthroplasty. Strain-gauge analysis and corresponding finite-element (FE) analysis were performed to assess the effect of friction and creep at the cement-stem interface. No difference was seen between the matt and polished stems. FE analysis showed that the effects of cement creep and friction at the stem-cement interface on femoral strain were small compared with the effect of inserting a cemented stem


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 899 - 901
1 Nov 1991
McMinn D Roberts P Forward G

A new approach to the hip is described that allows better exposure for difficult revision surgery without the need for trochanteric osteotomy. A V-shaped myofascial flap consisting of the proximal part of vastus lateralis and its fascia with gluteus medius and minimus, is reflected off the greater trochanter and proximal femur giving access to the entire capsule of the hip. If the leg has been significantly lengthened by the revision procedure, abductor tension can be adjusted at closure by altering the reattachment of the flap, analogous to a V-Y-plasty


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 32 - 37
1 Jan 1984
Leung P Chow Y

A new method of treating large bony defects of the proximal femur is described. The defect is filled with a large vascular-pedicled bone graft from the iliac crest. The graft, being nourished by the deep circumflex iliac vessels, remains viable and therefore induces rapid healing of the bone. This method of bony replacement encourages adequate excision of potentially malignant bone lesions and provides sufficient mechanical support to allow early walking. Six clinical cases are presented to illustrate its application


Bone & Joint Open
Vol. 2, Issue 1 | Pages 33 - 39
14 Jan 2021
McLaughlin JR Lee KR Johnson MA

Aims

We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years.

Methods

A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one.