Advertisement for orthosearch.org.uk
Results 2381 - 2400 of 3118
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 911 - 916
1 Jul 2013
Small SR Ritter MA Merchun JG Davis KE Rogge RD

Stress shielding resulting in diminished bone density following total knee replacement (TKR) may increase the risk of migration and loosening of the prosthesis. This retrospective study was designed to quantify the effects of the method of fixation on peri-prosthetic tibial bone density beneath cemented and uncemented tibial components of similar design and with similar long-term survival rates. Standard radiographs taken between two months and 15 years post-operatively were digitised from a matched group of TKRs using cemented (n = 67) and uncemented (n = 67) AGC tibial prostheses. Digital radiograph densitometry was used to quantify changes in bone density over time. Age, length of follow-up, gender, body mass index and alignment each significantly influenced the long-term pattern of peri-prosthetic bone density. Similar long-term changes in density irrespective of the method of fixation correlated well with the high rate of survival of this TKR at 20 years, and suggest that cemented and uncemented fixation are both equally viable.

Cite this article: Bone Joint J 2013;95-B:911–16.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 906 - 910
1 Jul 2013
Lin S Chen C Fu Y Huang P Lu C Su J Chang J Huang H

Minimally invasive total knee replacement (MIS-TKR) has been reported to have better early recovery than conventional TKR. Quadriceps-sparing (QS) TKR is the least invasive MIS procedure, but it is technically demanding with higher reported rates of complications and outliers. This study was designed to compare the early clinical and radiological outcomes of TKR performed by an experienced surgeon using the QS approach with or without navigational assistance (NA), or using a mini-medial parapatellar (MP) approach. In all, 100 patients completed a minimum two-year follow-up: 30 in the NA-QS group, 35 in the QS group, and 35 in the MP group. There were no significant differences in clinical outcome in terms of ability to perform a straight-leg raise at 24 hours (p = 0.700), knee score (p = 0.952), functional score (p = 0.229) and range of movement (p = 0.732) among the groups. The number of outliers for all three radiological parameters of mechanical axis, frontal femoral component alignment and frontal tibial component alignment was significantly lower in the NA-QS group than in the QS group (p = 0.008), but no outlier was found in the MP group.

In conclusion, even after the surgeon completed a substantial number of cases before the commencement of this study, the supplementary intra-operative use of computer-assisted navigation with QS-TKR still gave inferior radiological results and longer operating time, with a similar outcome at two years when compared with a MP approach.

Cite this article: Bone Joint J 2013;95-B:906–10.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 25 - 27
1 Jun 2013

The June 2013 Wrist & Hand Roundup360 looks at: whether size is a limitation; cancellous bone grafting in scaphoid nonunion; the Kienböck’s dichotomy; late displacement of the distal radius; flexor slide for finger contracture; aesthetic syndactyly; flexor tendon repair; and fixation of trapeziometacarpal cups.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 38 - 44
1 Jan 2013
Williams DP Price AJ Beard DJ Hadfield SG Arden NK Murray DW Field RE

We present a comparison of patient-reported outcomes (PROMs) in relation to patient age, in patients who had received a total (TKR) or unicompartmental knee replacement (UKR). The outcome was evaluated using the Oxford knee score (OKS), EuroQol (EQ-5D) and satisfaction scores. Patients aged 65 to 84 years demonstrated better pre-operative function scores than those aged < 65 years (OKS, p = 0.03; EQ-5D, p = 0.048) and those aged ≥ 85 years (OKS, p = 0.03). Post-operative scores were comparable across age groups, but a linear trend for greater post-operative improvement in OKS and EQ-5D was seen with decreasing age (p < 0.033). The overall mean satisfaction score at six months was 84.9, but those aged <  55 years exhibited a lower mean level of satisfaction (78.3) compared with all other age groups (all p < 0.031). The cumulative overall two-year revision rate was 1.3%. This study demonstrates that good early outcomes, as measured by the OKS and EQ-5D, can be anticipated following knee replacement regardless of the patient’s age, although younger patients gain greater improvement. However, the lower satisfaction in those aged < 55 years is a concern, and suggests that outcome is not fully encapsulated by the OKS and EQ-5D evaluation, and raises the question whether the OKS alone is an appropriate measure of pain and function in younger, more active individuals.

Cite this article: Bone Joint J 2013;95-B:38–44.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 23 - 30
1 Jan 2013
Kiernan S Hermann KL Wagner P Ryd L Flivik G

Progressive retroversion of a cemented stem is predictive of early loosening and failure. We assessed the relationship between direct post-operative stem anteversion, measured with CT, and the resulting rotational stability, measured with repeated radiostereometric analysis over ten years. The study comprised 60 cemented total hip replacements using one of two types of matt collared stem with a rounded cross-section. The patients were divided into three groups depending on their measured post-operative anteversion (< 10°, 10° to 25°, >  25°). There was a strong correlation between direct post-operative anteversion and later posterior rotation. At one year the < 10° group showed significantly more progressive retroversion together with distal migration, and this persisted to the ten-year follow-up. In the < 10° group four of ten stems (40%) had been revised at ten years, and an additional two stems (20%) were radiologically loose. In the ‘normal’ (10° to 25°) anteversion group there was one revised (3%) and one loose stem (3%) of a total of 30 stems, and in the > 25° group one stem (5%) was revised and another loose (5%) out of 20 stems. This poor outcome is partly dependent on the design of this prosthesis, but the results strongly suggest that the initial rotational position of cemented stems during surgery affects the subsequent progressive retroversion, subsidence and eventual loosening. The degree of retroversion may be sensitive to prosthetic design and stem size, but < 10° of anteversion appears deleterious to the long-term outcome for cemented hip prosthetic stems.

Cite this article: Bone Joint J 2013;95-B:23–30.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1660 - 1665
1 Dec 2012
Megerle K Bertel D Germann G Lehnhardt M Hellmich S

The purpose of this study was to assess the clinical and radiological outcomes of dorsal intercarpal ligament capsulodesis for the treatment of static scapholunate instability at a minimum follow-up of four years. A total of 59 patients who underwent capsulodesis for this condition were included in a retrospective analysis after a mean of 8.25 years (4.3 to 12). A total of eight patients underwent a salvage procedure at a mean of 2.33 years (0.67 to 7.6) and were excluded. The mean range of extension/flexion was 88° (15° to 135°) and of ulnar/radial deviation was 38° (0° to 75°) at final follow-up. The mean Disabilities of the Arm Shoulder and Hand (DASH) score and Mayo wrist scores were 28 (0 to 85) and 61 (0 to 90), respectively. After significant improvement immediately post-operatively (p < 0.001 and p = 0.001, respectively), the mean scapholunate and radiolunate angles deteriorated to 70° (40° to 90°) and 8° (-15° to 25°), respectively, at final follow-up, which were not significantly different from their pre-operative values (p = 0.6 and p = 0.4, respectively). The mean carpal height index decreased significantly from 1.53 (1.38 to 1.65) to 1.48 (1.29 to 1.65) indicating progressive carpal collapse (p < 0.001); 40 patients (78%) had radiological evidence of degenerative arthritis.

Capsulodesis did not maintain carpal reduction over time. Although the consequent ongoing scapholunate instability resulted in early arthritic degeneration, most patients had acceptable long-term function of the wrist.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 893 - 899
1 Jul 2013
Diaz-Ledezma C Novack T Marin-Peña O Parvizi J

Orthopaedic surgeons have accepted various radiological signs to be representative of acetabular retroversion, which is the main characteristic of focal over-coverage in patients with femoroacetabular impingement (FAI). Using a validated method for radiological analysis, we assessed the relevance of these signs to predict intra-articular lesions in 93 patients undergoing surgery for FAI. A logistic regression model to predict chondral damage showed that an acetabular retroversion index (ARI) > 20%, a derivative of the well-known cross-over sign, was an independent predictor (p = 0.036). However, ARI was less significant than the Tönnis classification (p = 0.019) and age (p = 0.031) in the same model. ARI was unable to discriminate between grades of chondral lesions, while the type of cam lesion (p = 0.004) and age (p = 0.047) were able to. Other widely recognised signs of acetabular retroversion, such as the ischial spine sign, the posterior wall sign or the cross-over sign were irrelevant according to our analysis. Regardless of its secondary predictive role, an ARI > 20% appears to be the most clinically relevant radiological sign of acetabular retroversion in symptomatic patients with FAI.

Cite this article: Bone Joint J 2013;95-B:893–9.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 788 - 792
1 Jun 2013
Chen JY Lo NN Jiang L Chong HC Tay DKJ Chin PL Chia S Yeo SJ

We prospectively followed 171 patients who underwent bilateral unicompartmental knee replacement (UKR) over a period of two years. Of these, 124 (72.5%) underwent a simultaneous bilateral procedure and 47 (27.5%) underwent a staged procedure. The mean cumulative operating time and length of hospital stay were both shorter in the simultaneous group, by 22.5 minutes (p < 0.001) and three days (p < 0.001), respectively. The mean reduction in haemoglobin level post-operatively was greater by 0.15 g/dl in the simultaneous group (p = 0.023), but this did not translate into a significant increase in the number of patients requiring blood transfusion (p = 1.000). The mean hospital cost was lower by $8892 in the simultaneous group (p < 0.001). There was no significant difference in the rate of complications between the groups, and at two-year follow-up there was no difference in the outcomes between the two groups.

We conclude that simultaneous bilateral UKR can be recommended as an appropriate treatment for patients with bilateral medial compartment osteoarthritis of the knee.

Cite this article: Bone Joint J 2013;95-B:788–92.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 14 - 18
1 Nov 2012
Lombardi, Jr AV Barrack RL Berend KR Cuckler JM Jacobs JJ Mont MA Schmalzried TP

Since 1996 more than one million metal-on-metal articulations have been implanted worldwide. Adverse reactions to metal debris are escalating. Here we present an algorithmic approach to patient management. The general approach to all arthroplasty patients returning for follow-up begins with a detailed history, querying for pain, discomfort or compromise of function. Symptomatic patients should be evaluated for intra-articular and extra-articular causes of pain. In large head MoM arthroplasty, aseptic loosening may be the source of pain and is frequently difficult to diagnose. Sepsis should be ruled out as a source of pain. Plain radiographs are evaluated to rule out loosening and osteolysis, and assess component position. Laboratory evaluation commences with erythrocyte sedimentation rate and C-reactive protein, which may be elevated. Serum metal ions should be assessed by an approved facility. Aspiration, with manual cell count and culture/sensitivity should be performed, with cloudy to creamy fluid with predominance of monocytes often indicative of failure. Imaging should include ultrasound or metal artifact reduction sequence MRI, specifically evaluating for fluid collections and/or masses about the hip. If adverse reaction to metal debris is suspected then revision to metal or ceramic-on-polyethylene is indicated and can be successful. Delay may be associated with extensive soft-tissue damage and hence poor clinical outcome.


Bone & Joint Research
Vol. 2, Issue 8 | Pages 169 - 178
1 Aug 2013
Rodrigues-Pinto R Richardson SM Hoyland JA

Mesenchymal stem-cell based therapies have been proposed as novel treatments for intervertebral disc degeneration, a prevalent and disabling condition associated with back pain. The development of these treatment strategies, however, has been hindered by the incomplete understanding of the human nucleus pulposus phenotype and by an inaccurate interpretation and translation of animal to human research. This review summarises recent work characterising the nucleus pulposus phenotype in different animal models and in humans and integrates their findings with the anatomical and physiological differences between these species. Understanding this phenotype is paramount to guarantee that implanted cells restore the native functions of the intervertebral disc.

Cite this article: Bone Joint Res 2013;2:169–78.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 85 - 89
1 Nov 2012
Drexler M Dwyer T Marmor M Abolghasemian M Sternheim A Cameron HU

In this study we present our experience with four generations of uncemented total knee arthroplasty (TKA) from Smith & Nephew: Tricon M, Tricon LS, Tricon II and Profix, focusing on the failure rates correlating with each design change. Beginning in 1984, 380 Tricon M, 435 Tricon LS, 305 Tricon 2 and 588 Profix were implanted by the senior author. The rate of revision for loosening was 1.1% for the Tricon M, 1.1% for the Tricon LS, 0.5% for the Tricon 2 with a HA coated tibial component, and 1.3% for the Profix TKA. No loosening of the femoral component was seen with the Tricon M, Tricon LS or Tricon 2, with no loosening seen of the tibial component with the Profix TKA. Regarding revision for wear, the incidence was 13.1% for the Tricon M, 6.6% for the Tricon LS, 2.3% for the Tricon 2, and 0% for the Profix. These results demonstrate that improvements in the design of uncemented components, including increased polyethylene thickness, improved polyethylene quality, and the introduction of hydroxyapatite coating, has improved the outcomes of uncemented TKA over time.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1071 - 1076
1 Aug 2012
Lim H Bae J Song S Kim S

Medium-term survivorship of the Oxford phase 3 unicompartmental knee replacement (UKR) has not yet been established in an Asian population. We prospectively evaluated the outcome of 400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at the time of operation of 69 years (48 to 82). The mean follow-up was 5.2 years (1 to 10). Clinical and radiological assessment was carried out pre- and post-operatively. At five years, the mean Knee Society knee and functional scores had increased significantly from 56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively. The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival rate was 94% (95% confidence interval 90.1 to 98.0). A total of 14 UKRs (3.5%) required revision. The most common reason for revision was dislocation of the bearing in 12 (3%). Conversion to a total knee replacement was required in two patients who developed osteoarthritis of the lateral compartment.

This is the largest published series of UKR in Korean patients. It shows that the mid-term results after a minimally invasive Oxford phase 3 UKR can yield satisfactory clinical and functional results in this group of patients.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 12 - 14
1 Jun 2012

The June 2012 Knee Roundup360 looks at: ACI and mosaicplasty; ACI after microfracture; exercise therapy and the degenerate medial meniscal tear; intra-articular bupivacaine or ropivacaine at knee arthroscopy; lateral trochlear inclination and patellofemoral osteoarthritis; bone loss and ACL reconstruction; assessing stability using the contralateral knee; tranexamic acid and a useful review of knee replacement.


Bone & Joint Research
Vol. 2, Issue 6 | Pages 116 - 121
1 Jun 2013
Duijnisveld BJ Saraç Ç Malessy MJA Brachial Plexus Advisory Board TI Vliet Vlieland TPM Nelissen RGHH

Background

Symptoms of obstetric brachial plexus injury (OBPI) vary widely over the course of time and from individual to individual and can include various degrees of denervation, muscle weakness, contractures, bone deformities and functional limitations. To date, no universally accepted overall framework is available to assess the outcome of patients with OBPI. The objective of this paper is to outline the proposed process for the development of International Classification of Functioning, Disability and Health (ICF) Core Sets for patients with an OBPI.

Methods

The first step is to conduct four preparatory studies to identify ICF categories important for OBPI: a) a systematic literature review to identify outcome measures, b) a qualitative study using focus groups, c) an expert survey and d) a cross-sectional, multicentre study. A first version of ICF Core Sets will be defined at a consensus conference, which will integrate the evidence from the preparatory studies. In a second step, field-testing among patients will validate this first version of Core Sets for OBPI.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 19 - 21
1 Jun 2012

The June 2012 Shoulder & Elbow Roundup360 looks at: reverse shoulder replacement; torn rotator cuffs and platelet-rich fibrin; rotator cuff repair; frozen shoulder; whether an arthroscopic rotator cuff repair actually heals; the torn rotator cuff’s effect on activities of daily living; subacromial impingement; how to improve the reliability of the Constant-Murley score; and failure of the Neer modification of an open Bankart procedure.


Bone & Joint Research
Vol. 1, Issue 10 | Pages 234 - 237
1 Oct 2012
Hughes AW Dwyer AJ Govindaswamy R Lankester B

Objectives

Our aim was to assess the use of intra-operative fluoroscopy in the assessment of the position of the tibial tunnel during reconstruction of the anterior cruciate ligament (ACL).

Methods

Between January and June 2009 a total of 31 arthroscopic hamstring ACL reconstructions were performed. Intra-operative fluoroscopy was introduced (when available) to verify the position of the guidewire before tunnel reaming. It was only available for use in 20 cases, due to other demands on the radiology department. The tourniquet times were compared between the two groups and all cases where radiological images lead to re-positioning of the guide wire were recorded. The secondary outcome involved assessing the tibial interference screw position measured on post-operative radiographs and comparing with the known tunnel position as shown on intra-operative fluoroscopic images.


Bone & Joint Research
Vol. 2, Issue 7 | Pages 132 - 139
1 Jul 2013
Ketola S Lehtinen J Rousi T Nissinen M Huhtala H Konttinen YT Arnala I

Objectives

To report the five-year results of a randomised controlled trial examining the effectiveness of arthroscopic acromioplasty in the treatment of stage II shoulder impingement syndrome.

Methods

A total of 140 patients were randomly divided into two groups: 1) supervised exercise programme (n = 70, exercise group); and 2) arthroscopic acromioplasty followed by a similar exercise programme (n = 70, combined treatment group).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 459 - 465
1 Apr 2012
Nikolaou VS Edwards MR Bogoch E Schemitsch EH Waddell JP

The ideal bearing surface for young patients undergoing total hip replacement (THR) remains controversial. We report the five-year results of a randomised controlled trial comparing the clinical and radiological outcomes of 102 THRs in 91 patients who were <  65 years of age. These patients were randomised to receive a cobalt–chrome on ultra-high-molecular-weight polyethylene, cobalt–chrome on highly cross-linked polyethylene, or a ceramic-on-ceramic bearing. In all, 97 hip replacements in 87 patients were available for review at five years. Two hips had been revised, one for infection and one for peri-prosthetic fracture.

At the final follow-up there were no significant differences between the groups for the mean Western Ontario and McMaster Universities osteoarthritis index (pain, p = 0.543; function, p = 0.10; stiffness, p = 0.99), Short Form-12 (physical component, p = 0.878; mental component, p = 0.818) or Harris hip scores (p = 0.22). Radiological outcomes revealed no significant wear in the ceramic group.

Comparison of standard and highly cross-linked polyethylene, however, revealed an almost threefold difference in the mean annual linear wear rates (0.151 mm/year versus 0.059 mm/year, respectively) (p < 0.001).


Bone & Joint 360
Vol. 1, Issue 5 | Pages 30 - 32
1 Oct 2012

The October 2012 Research Roundup360 looks at: whether you can escape your genes; oral prophylaxis for DVT; non-responders and the internet; metal-on-metal, mice and damaged livers; sleeping on the job; cartilage contact stress in the normal human hip; and a perfect reason to subscribe to 360.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 103 - 111
1 Nov 2012
Vince KG

Seven stiff total knee arthroplasties are presented to illustrate the roles of: 1) manipulation under general anesthesia; 2) multiple concurrent diagnoses in addition to stiffness; 3) extra-articular pathology; 4) pain as part of the stiffness triad (pain and limits to flexion or extension); 5) component internal rotation; 6) multifactorial etiology; and 7) surgical exposure in this challenging clinical problem.