Advertisement for orthosearch.org.uk
Results 221 - 240 of 8475
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1537 - 1544
1 Nov 2017
Wahl P Guidi M Benninger E Rönn K Gautier E Buclin T Magnin J Livio F

Aims. Calcium sulphate (CaSO. 4. ) is a resorbable material that can be used simultaneously as filler of a dead space and as a carrier for the local application of antibiotics. Our aim was to describe the systemic exposure and the wound fluid concentrations of vancomycin in patients treated with vancomycin-loaded CaSO. 4. as an adjunct to the routine therapy of bone and joint infections. Patients and Methods. A total of 680 post-operative blood and 233 wound fluid samples were available for analysis from 94 implantations performed in 87 patients for various infective indications. Up to 6 g of vancomycin were used. Non-compartmental pharmacokinetic analysis was performed on the data from 37 patients treated for an infection of the hip. Results. The overall systemic exposure remained within a safe range, even in patients with post-operative renal failure, none requiring removal of the pellets. Local concentrations were approximately ten times higher than with polymethylmethacrylate (PMMA) as a carrier, but remained below reported cell toxicity thresholds. Decreasing concentrations in wound fluid were observed over several weeks, but remained above the common minimum inhibitory concentrations for Staphylococcus up to three months post-operatively. . Conclusion. This study provides the first pharmacokinetic description of the local application of vancomycin with CaSO. 4. as a carrier, documenting slow release, systemic safety and a release profile far more interesting than from PMMA. In particular, considering in vitro data, concentrations of vancomycin active against staphylococcal biofilm were seen for several weeks. Cite this article: Bone Joint J 2017;99-B:1537–44


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 677 - 683
1 May 2014
Greenberg A Berenstein Weyel T Sosna J Applbaum J Peyser A

Osteoid osteoma is treated primarily by radiofrequency (RF) ablation. However, there is little information about the distribution of heat in bone during the procedure and its safety. We constructed a model of osteoid osteoma to assess the distribution of heat in bone and to define the margins of safety for ablation. Cavities were drilled in cadaver bovine bones and filled with a liver homogenate to simulate the tumour matrix. Temperature-sensing probes were placed in the bone in a radial fashion away from the cavities. RF ablation was performed 107 times in tumours < 10 mm in diameter (72 of which were in cortical bone, 35 in cancellous bone), and 41 times in cortical bone with models > 10 mm in diameter. Significantly higher temperatures were found in cancellous bone than in cortical bone (p <  0.05). For lesions up to 10 mm in diameter, in both bone types, the temperature varied directly with the size of the tumour (p < 0.05), and inversely with the distance from it. Tumours of > 10 mm in diameter showed a trend similar to those of smaller lesions. No temperature rise was seen beyond 12 mm from the edge of a cortical tumour of any size. Formulae were developed to predict the expected temperature in the bone during ablation. Cite this article: Bone Joint J 2014; 96-B:677–83


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 590 - 595
1 May 2018
Sawa M Nakasa T Ikuta Y Yoshikawa M Tsuyuguchi Y Kanemitsu M Ota Y Adachi N

Aims. The aim of this study was to evaluate antegrade autologous bone grafting with the preservation of articular cartilage in the treatment of symptomatic osteochondral lesions of the talus with subchondral cysts. Patients and Methods. The study involved seven men and five women; their mean age was 35.9 years (14 to 70). All lesions included full-thickness articular cartilage extending through subchondral bone and were associated with subchondral cysts. Medial lesions were exposed through an oblique medial malleolar osteotomy, and one lateral lesion was exposed by expanding an anterolateral arthroscopic portal. After refreshing the subchondral cyst, it was grafted with autologous cancellous bone from the distal tibial metaphysis. The fragments of cartilage were fixed with 5-0 nylon sutures to the surrounding cartilage. Function was assessed at a mean follow-up of 25.3 months (15 to 50), using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot outcome score. The radiological outcome was assessed using MRI and CT scans. Results. The mean AOFAS score improved from 65.7 (47 to 81) preoperatively to 92 (90 to 100) at final follow-up, with 100% patient satisfaction. The radiolucent area of the cysts almost disappeared on plain radiographs in all patients immediately after surgery, and there were no recurrences at the most recent follow-up. The medial malleolar screws were removed in seven patients, although none had symptoms. At this time, further arthroscopy was undertaken, when it was found that the mean International Cartilage Repair Society (ICRS) arthroscopic score represented near-normal cartilage. Conclusion. Autologous bone grafting with fixation of chondral fragments preserves the original cartilage in the short term, and could be considered in the treatment for adult patients with symptomatic osteochondral defect and subchondral cysts. Cite this article: Bone Joint J 2018;100-B:590–5


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1503 - 1509
1 Nov 2014
Ritter MA Davis KE Small SR Merchun JG Farris A

The relationship between post-operative bone density and subsequent failure of total knee replacement (TKR) is not known. This retrospective study aimed to determine the relationship between bone density and failure, both overall and according to failure mechanism. All 54 aseptic failures occurring in 50 patients from 7760 consecutive primary cemented TKRs between 1983 and 2004 were matched with non-failing TKRs, and 47 failures in 44 patients involved tibial failures with the matching characteristics of age (65.1 for failed and 69.8 for non-failed), gender (70.2% female), diagnosis (93.6% OA), date of operation, bilaterality, pre-operative alignment (0.4 and 0.3 respectively), and body mass index (30.2 and 30.0 respectively). In each case, the density of bone beneath the tibial component was assessed at each follow-up interval using standardised, calibrated radiographs. Failing knees were compared with controls both overall and, as a subgroup analysis, by failure mechanism. Knees were compared with controls using univariable linear regression. Significant and continuous elevation in tibial density was found in knees that eventually failed by medial collapse (p < 0.001) and progressive radiolucency (p < 0.001) compared with controls, particularly in the medial region of the tibia. Knees failing due to ligamentous instability demonstrated an initial decline in density (p = 0.0152) followed by a non-decreasing density over time (p = 0.034 for equivalence). Non-failing knees reported a decline in density similar to that reported previously using dual-energy x-ray absorptiometry (DEXA). Differences between failing and non-failing knees were observable as early as two months following surgery. This tool may be used to identify patients at risk of failure following TKR, but more validation work is needed. Cite this article: Bone Joint J 2014;96-B:1503–9


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 73 - 77
1 Jan 2017
Frew NM Cannon T Nichol T Smith TJ Stockley I

Aims. Vancomycin is commonly added to acrylic bone cement during revision arthroplasty surgery. Proprietary cement preparations containing vancomycin are available, but are significantly more expensive. We investigated whether the elution of antibiotic from ‘home-made’ cement containing vancomycin was comparable with more expensive commercially available vancomycin impregnated cement. Materials and Methods. A total of 18 cement discs containing either proprietary CopalG+V; or ‘home-made’ CopalR+G with vancomycin added by hand, were made. Each disc contained the same amount of antibiotic (0.5 g gentamycin, 2 g vancomycin) and was immersed in ammonium acetate buffer in a sealed container. Fluid from each container was sampled at eight time points over a two-week period. The concentrations of gentamicin and vancomycin in the fluid were analysed using high performance liquid chromatography mass spectrometry. Results. The highest peak concentrations of antibiotic were observed from the ‘home-made’ cements containing vancomycin, added as in the operating theatre. The overall elution of antibiotic was, fivefold (vancomycin) and twofold (gentamicin) greater from the ‘home-made’ mix compared with the commercially mixed cement. The use of a vacuum during mixing had no significant effect on antibiotic elution in any of the samples. Conclusion. These findings suggest that the addition of 2 g vancomycin powder to gentamicin-impregnated bone cement by hand significantly increases the elution of both antibiotics compared with commercially prepared cements containing vancomycin. We found no significant advantages of using expensive commercially produced vancomycin-impregnated cement and recommend the addition of vancomycin powder by hand in the operating theatre. Cite this article: Bone Joint J 2017;99-B:73–7


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 607 - 613
1 May 2017
Mäkinen TJ Abolghasemian M Watts E Fichman SG Kuzyk P Safir OA Gross AE

Aims. It may not be possible to undertake revision total hip arthroplasty (THA) in the presence of massive loss of acetabular bone stock using standard cementless hemispherical acetabular components and metal augments, as satisfactory stability cannot always be achieved. We aimed to study the outcome using a reconstruction cage and a porous metal augment in these patients. Patients and Methods. A total of 22 acetabular revisions in 19 patients were performed using a combination of a reconstruction cage and porous metal augments. The augments were used in place of structural allografts. The mean age of the patients at the time of surgery was 70 years (27 to 85) and the mean follow-up was 39 months (27 to 58). The mean number of previous THAs was 1.9 (1 to 3). All patients had segmental defects involving more than 50% of the acetabulum and seven hips had an associated pelvic discontinuity. . Results. Three failures were observed in two hips, both of which had undergone a previous resection of a tumour affecting the acetabulum. Other complications included a late arterial injury, a sciatic nerve palsy, a dislocation treated with a femoral revision, a deep infection treated with irrigation and debridement and a fracture of the greater trochanter treated conservatively. The mean Oxford Hip Score significantly increased from 13.9 (2 to 23) to 28.7 (13 to 38) (p < 0.00001). The mean vertical distance between the centre of rotation of the hip and its normal location decreased from 30 mm to 10 mm. Conclusions. Acceptable early survivorship can be achieved using this novel technique, but it may be unsuitable for use in patients who have previously undergone the resection of a tumour involving the acetabulum. Cite this article: Bone Joint J 2017;99-B:607–13


Bone & Joint Research
Vol. 3, Issue 1 | Pages 14 - 19
1 Jan 2014
James SJ Mirza SB Culliford DJ Taylor PA Carr AJ Arden NK

Aims. Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic loosening and peri-prosthetic fracture. We aimed to investigate baseline bone mineral density (BMD) and bone turnover in patients about to undergo arthroplasty of the hip and knee. Methods. We prospectively measured bone mineral density of the hip and lumbar spine using dual-energy X-ray absorptiometry (DEXA) scans in a cohort of 194 patients awaiting hip or knee arthroplasty. We also assessed bone turnover using urinary deoxypyridinoline (DPD), a type I collagen crosslink, normalised to creatinine. Results. The prevalence of DEXA proven hip osteoporosis (T-score ≤ -2.5) among hip and knee arthroplasty patients was found to be low at 2.8% (4 of 143). Spinal osteoporosis prevalence was higher at 6.9% (12 of 175). Sixty patients (42% (60 of 143)) had osteopenia or osteoporosis of either the hip or spine. The mean T-score for the hip was -0.34 (. sd. 1.23), which is within normal limits, and the mean hip Z-score was positive at 0.87 (. sd. 1.17), signifying higher-than-average BMD for age. The median urinary DPD/creatinine was raised in both female patients at 8.1 (interquartile range (IQR) 6.6 to 9.9) and male patients at 6.2 (IQR 4.8 to 7.5). Conclusions. Our results indicate hip and knee arthroplasty patients have higher BMD of the hip and spine compared with an age-matched general population, and a lower prevalence of osteoporosis. However, untreated osteoporotic patients are undergoing arthroplasty, which may negatively impact their outcome. Raised DPD levels suggest abnormal bone turnover, requiring further investigation. Cite this article: Bone Joint Res 2014;3:14–19


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1673 - 1680
1 Dec 2013
Papakostidis C Bhandari M Giannoudis PV

We carried out a systematic review of the literature to evaluate the evidence regarding the clinical results of the Ilizarov method in the treatment of long bone defects of the lower limbs. Only 37 reports (three non-randomised comparative studies, one prospective study and 33 case-series) met our inclusion criteria. Although several studies were unsatisfactory in terms of statistical heterogeneity, our analysis appears to show that the Ilizarov method of distraction osteogenesis significantly reduced the risk of deep infection in infected osseous lesions (risk ratio 0.14 (95% confidence interval (CI) 0.10 to 0.20), p < 0.001). However, there was a rate of re-fracture of 5% (95% CI 3 to 7), with a rate of neurovascular complications of 2.2% (95% CI 0.3 to 4) and an amputation rate of 2.9% (95% CI 1.4 to 4.4).The data was generally not statistically heterogeneous. Where tibial defects were > 8 cm, the risk of re-fracture increased (odds ratio 3.7 (95% CI 1.1 to 12.5), p = 0.036). . The technique is demanding for patients, illustrated by the voluntary amputation rate of 1.6% (95% CI 0 to 3.1), which underlines the need for careful patient selection. Cite this article: Bone Joint J 2013;95-B:1673–80


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1489 - 1492
1 Nov 2010
Grimer RJ Briggs TWR

Although bone and soft-tissue sarcomas are rare, early diagnosis and prompt referral to a specialised unit offers the best chance of a successful outcome both in terms of survival and surgical resection. This paper highlights the clinical and radiological features that might suggest the possibility of a bone or soft-tissue sarcoma and suggests a succinct management pathway for establishing whether a suspicious bone or soft-tissue lesion could be malignant


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1227 - 1231
1 Sep 2009
Abuhassan FO Shannak AO

We describe the treatment by subperiosteal resection of an aneurysmal bone cyst in the distal fibula in eight patients and highlight the role of the periosteum in the regeneration of bone defects. The mean age of the patients was 13.5 years (12 to 17). Seven had an open growth plate. The mean size of the resected specimen was 5.12 cm (3.5 to 8.0). None of the patients received instillation of bone marrow, autogenous bone graft, allograft or any synthetic bone substitutes. All had complete regeneration of the bone defect within three to nine months, with no joint instability or recurrence. The mean length of follow-up was 11.5 years (2 to 18). At the final follow-up there was no difference in the range of movement, alignment or stability of the ankle when compared with the opposite side. The periosteum played a major role in the complete filling of the bone defects and avoided the morbidity of other techniques


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1338 - 1344
1 Oct 2015
te Stroet MAJ Keurentjes JC Rijnen WHC Gardeniers JWM Verdonschot N Slooff TJJH Schreurs BW

We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). . We performed Kaplan–Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. . A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint ‘re-revision for any reason’ was 58.0% (95% confidence interval (CI) 38 to 73) and for ‘re-revision for aseptic loosening’ 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years. Cite this article: Bone Joint J 2015;97-B:1338–44


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1164 - 1171
1 Sep 2008
Ochs BG Schmid U Rieth J Ateschrang A Weise K Ochs U

Deficiencies of acetabular bone stock at revision hip replacement were reconstructed with two different types of allograft using impaction bone grafting and a Burch-Schneider reinforcement ring. We compared a standard frozen non-irradiated bone bank allograft (group A) with a freeze-dried irradiated bone allograft, vitalised with autologous marrow (group B). We studied 78 patients (79 hips), of whom 87% (69 hips) had type III acetabular defects according to the American Academy of Orthopaedic Surgeons classification at a mean of 31.4 months (14 to 51) after surgery. At the latest follow-up, the mean Harris hip score was 69.9 points (13.5 to 97.1) in group A and 71.0 points (11.5 to 96.5) in group B. Each hip showed evidence of trabeculation and incorporation of the allograft with no acetabular loosening. These results suggest that the use of an acetabular reinforcement ring and a living composite of sterile allograft and autologous marrow appears to be a method of reconstructing acetabular deficiencies which gives comparable results to current forms of treatment


Bone & Joint Research
Vol. 6, Issue 5 | Pages 296 - 306
1 May 2017
Samara E Moriarty TF Decosterd LA Richards RG Gautier E Wahl P

Objectives. Thermal stability is a key property in determining the suitability of an antibiotic agent for local application in the treatment of orthopaedic infections. Despite the fact that long-term therapy is a stated goal of novel local delivery carriers, data describing thermal stability over a long period are scarce, and studies that avoid interference from specific carrier materials are absent from the orthopaedic literature. Methods. In this study, a total of 38 frequently used antibiotic agents were maintained at 37°C in saline solution, and degradation and antibacterial activity assessed over six weeks. The impact of an initial supplementary heat exposure mimicking exothermically curing bone cement was also tested as this material is commonly used as a local delivery vehicle. Antibiotic degradation was assessed by liquid chromatography coupled to mass spectrometry, or by immunoassays, as appropriate. Antibacterial activity over time was determined by the Kirby-Bauer disk diffusion assay. Results. The heat exposure mimicking curing bone cement had minimal effect on stability for most antibiotics, except for gentamicin which experienced approximately 25% degradation as measured by immunoassay. Beta-lactam antibiotics were found to degrade quite rapidly at 37°C regardless of whether there was an initial heat exposure. Excellent long-term stability was observed for aminoglycosides, glycopeptides, tetracyclines and quinolones under both conditions. Conclusions. This study provides a valuable dataset for orthopaedic surgeons considering local application of antibiotics, and for material scientists looking to develop next-generation controlled or extended-release antibiotic carriers. Cite this article: E. Samara, T. F. Moriarty, L. A. Decosterd, R. G. Richards, E. Gautier, P. Wahl. Antibiotic stability over six weeks in aqueous solution at body temperature with and without heat treatment that mimics the curing of bone cement. Bone Joint J 2017;6:296–306. DOI: 10.1302/2046-3758.65.BJR-2017-0276.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 3 | Pages 532 - 566
1 Aug 1966
Burwell RG

1. The present study is an attempt to analyse and apportion significance to the role of inductive mechanisms in bone transplantation. 2. The experimental model used in the present work is that of the composite homograftautograft of cancellous bone previously described (Burwell 1964a). 3. Iliac bone was removed from hooded rats and washed free from its marrow. The bone was then treated by various physical and chemical methods (some of which have been used by other workers to prepare bank bone), namely freezing (-20 degrees Centigrade, -79 degrees Centigrade, -196 degrees Centigrade); freeze-drying (without sterilisation, sterilisation with high energy radiation, sterilisation with ß-propiolactone); decalcification (with E.D.T.A.); irradiation (in the frozen state at a dose of 4 million rads); boiling in water; immersion in merthiolate solution; extraction of organic components with ethylenediamine: and calcining at 660 degrees Centigrade. The treated bone was then impregnated with fresh autologous marrow procured from the femoral shaft of the Wistar rat into which the treated composite graft was to be implanted. The grafts were inserted intramuscularly and removed for study after two, six and twelve weeks. 4. After fixation, serial sectioning and staining, each graft was examined microscopically, and the proportion of new bone/grafted bone scored using an arbitrary scale (0-4). The mean score (and the standard error of the mean score) was then plotted for each treated composite graft and also for several types of fresh cancellous bone grafts. 5. It was found (Fig. 2) that the various treated composite grafts formed a spectrum of bone-forming capacities–the maximum scores being attained by the frozen and freeze-dried composite grafts, the lowest scores by the "deproteinised" composite grafts. 6. The reasons for these differences are discussed. It is concluded that cancellous bone, after transplantation, has the property to induce and promote osteogenesis in marrow; moreover, that this property is contained in the organic components of bone. 7. From the standpoint of inductive mechanisms, cancellous bone treated by freezing or freeze-drying seems to be the most suitable devitalised bone for grafting purposes; bone which has been boiled or merthiolated less suitable; and "deproteinised" bone the least suitable. 8. Freeze-dried bone sterilised physically (by high energy radiation) or chemically (by ß-propiolactone) did not form significantly less new bone than did freeze-dried bone which had not been sterilised. 9. Remodelling mechanisms in bone transplantation are briefly discussed and attention drawn to the deficiencies of present knowledge. The quantitative studies of other workers have indicated that freeze-dried bone may be more rapidly remodelled than is frozen bone. 10. The importance of fresh red marrow in promoting osteogenesis in bone transplantation and in the healing of certain fractures, is emphasised. It seems likely that the interrelationship of bone and marrow revealed by experiment has wider significance not only in health and in response to injury but also in causation of certain idiopathic bone disorders


Bone & Joint Research
Vol. 4, Issue 10 | Pages 170 - 175
1 Oct 2015
Sandberg OH Aspenberg P

Objectives. Healing in cancellous metaphyseal bone might be different from midshaft fracture healing due to different access to mesenchymal stem cells, and because metaphyseal bone often heals without a cartilaginous phase. Inflammation plays an important role in the healing of a shaft fracture, but if metaphyseal injury is different, it is important to clarify if the role of inflammation is also different. The biology of fracture healing is also influenced by the degree of mechanical stability. It is unclear if inflammation interacts with stability-related factors. Methods. We investigated the role of inflammation in three different models: a metaphyseal screw pull-out, a shaft fracture with unstable nailing (IM-nail) and a stable external fixation (ExFix) model. For each, half of the animals received dexamethasone to reduce inflammation, and half received control injections. Mechanical and morphometric evaluation was used. Results. As expected, dexamethasone had a strong inhibitory effect on the healing of unstable, but also stable, shaft fractures. In contrast, dexamethasone tended to increase the mechanical strength of metaphyseal bone regenerated under stable conditions. Conclusions. It seems that dexamethasone has different effects on metaphyseal and diaphyseal bone healing. This could be explained by the different role of inflammation at different sites of injury. Cite this article: Bone Joint Res 2015;4:170–175


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1427 - 1432
1 Oct 2012
Chassanidis CG Malizos KN Varitimidis S Samara S Koromila T Kollia P Dailiana Z

Periosteum is important for bone homoeostasis through the release of bone morphogenetic proteins (BMPs) and their effect on osteoprogenitor cells. Smoking has an adverse effect on fracture healing and bone regeneration. The aim of this study was to evaluate the effect of smoking on the expression of the BMPs of human periosteum. Real-time polymerase chain reaction was performed for BMP-2,-4,-6,-7 gene expression in periosteal samples obtained from 45 fractured bones (19 smokers, 26 non-smokers) and 60 non-fractured bones (21 smokers, 39 non-smokers). A hierarchical model of BMP gene expression (BMP-2 > BMP-6 > BMP-4 > BMP-7) was demonstrated in all samples. When smokers and non-smokers were compared, a remarkable reduction in the gene expression of BMP-2, -4 and -6 was noticed in smokers. The comparison of fracture and non-fracture groups demonstrated a higher gene expression of BMP-2, -4 and -7 in the non-fracture samples. Within the subgroups (fracture and non-fracture), BMP gene expression in smokers was either lower but without statistical significance in the majority of BMPs, or similar to that in non-smokers with regard to BMP-4 in fracture and BMP-7 in non-fracture samples. In smokers, BMP gene expression of human periosteum was reduced, demonstrating the effect of smoking at the molecular level by reduction of mRNA transcription of periosteal BMPs. Among the BMPs studied, BMP-2 gene expression was significantly higher, highlighting its role in bone homoeostasis


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 836 - 841
1 Jun 2015
Jónsson BY Mjöberg B

A total of 20 patients with a depressed fracture of the lateral tibial plateau (Schatzker II or III) who would undergo open reduction and internal fixation were randomised to have the metaphyseal void in the bone filled with either porous titanium granules or autograft bone. Radiographs were undertaken within one week, after six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower (p < 0.001) and the operating time less (p < 0.002) when titanium granules were used. The indication is that it is therefore beneficial to use porous titanium granules than autograft bone to fill the void created by reducing a depressed fracture of the lateral tibial plateau. There is no donor site morbidity, the operating time is shorter and the risk of recurrent depression of the articular surface is less. . Cite this article: Bone Joint J 2015; 97-B:836–41


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 606 - 613
1 May 2006
Abu-Rajab RB Watson WS Walker B Roberts J Gallacher SJ Meek RMD

We compared peri-prosthetic bone mineral density between identical cemented and cementless LCS rotating platform total knee arthroplasties. Two matched cohorts had dual energy x-ray absorptiometry scans two years post-operatively using a modified validated densitometric analysis protocol, to assess peri-prosthetic bone mineral density. The knee that was not operated on was also scanned to enable the calculation of a relative bone mineral density difference. Oxford Knee and American Knee Society scores were comparable in the two cohorts. Statistical analysis revealed no significant difference in absolute, or relative peri-prosthetic bone mineral density with respect to the method of fixation. However, the femoral peri-prosthetic bone mineral density and relative bone mineral density difference were significantly decreased, irrespective of the method of fixation, particularly in the anterior distal portion of the femur, with a mean reduction in relative bone mineral density difference of 27%. There was no difference in clinical outcome between the cemented and cementless LCS total knee arthroplasty. However, both produce stress-shielding around the femoral implants. This leads us to question the use of more expensive cementless total knee components


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 4 | Pages 814 - 819
1 Nov 1961
BURWELL RG Gowland G

1. An immunological examination of the sera of thirty rabbits which had received primary and secondary homografts of cancellous bone into a subcutaneous site did not reveal the presence of circulating precipitins, haemagglutinins or passive haemagglutinins. These findings are consistent with the observations of Bonfiglio and his colleagues (1955). 2. Electrophoretic examination of the serum of four rabbits receiving primary and secondary homografts of bone into an intramuscular site did not reveal any change in the serum protein fractions. 3. A search for auto-antibodies produced by primary and secondary autografts of cancellous bone was unsuccessful in fifteen rabbits. 4. The multiple injections of saline extracts of bone into four rabbits did not evoke the production of demonstrable circulating antibodies, results which are in accord with the findings of Bonfiglio and colleagues (1955) and Curtiss and colleagues (1959). 5. For the first time the production of classical antibodies in response to injections of extracts of heterologous bone has been recorded. The repeated injections of a saline extract of rabbit bone intraperitoneally into ten mice produced demonstrable precipitins and passive haemagglutinins both to protein and polysaccharide fractions present in the bone extracts. 6. Knowledge concerning the production of humoral antibodies to transplants and extracts of bone has been reviewed


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1566 - 1571
1 Nov 2015
Salunke AA Chen Y Chen X Tan JH Singh G Tai BC Khin LW Puhaindran ME

We investigated whether the presence of a pathological fracture increased the risk of local recurrence in patients with a giant cell tumour (GCT) of bone. We also assessed if curettage is still an appropriate form of treatment in the presence of a pathological fracture. We conducted a comprehensive review and meta-analysis of papers which reported outcomes in patients with a GCT with and without a pathological fracture at presentation. We computed the odds ratio (OR) of local recurrence in those with and without a pathological fracture. . We selected 19 eligible papers for final analysis. This included 3215 patients, of whom 580 (18.0%) had a pathological fracture. The pooled OR for local recurrence between patients with and without a pathological fracture was 1.05 (95% confidence interval (CI) 0.66 to 1.67, p = 0.854). Amongst the subgroup of patients who were treated with curettage, the pooled OR for local recurrence was 1.23 (95% CI 0.75 to 2.01, p = 0.417). . A post hoc sample size calculation showed adequate power for both comparisons. . There is no difference in local recurrence rates between patients who have a GCT of bone with and without a pathological fracture at the time of presentation. The presence of a pathological fracture should not preclude the decision to perform curettage as carefully selected patients who undergo curettage can have similar outcomes in terms of local recurrence to those without such a fracture. Cite this article: Bone Joint J 2015;97-B:1566–71