A total of 219 hips in 192 patients aged between
18 and 65 years were randomised to 28-mm metal-on-metal uncemented
total hip replacements (THRs, 107 hips) or hybrid hip resurfacing
(HR, 112 hips). At a mean follow-up of eight years (6.6 to 9.3)
there was no significant difference between the THR and HR groups
regarding rate of revision (4.0% (4 of 99) Cite this article:
Obesity is an epidemic across both the developed
and developing nations that is possibly the most important current
public health factor affecting the morbidity and mortality of the global
population. Obese patients have the potential to pose several challenges
for arthroplasty surgeons from the standpoint of the influence obesity
has on osteoarthritic symptoms, their peri-operative medical management,
the increased intra-operative technical demands on the surgeon,
the intra- and post-operative complications, the long term outcomes
of total hip and knee arthroplasty. Also, there is no consensus
on the role the arthroplasty surgeon should have in facilitating
weight loss for these patients, nor whether obesity should affect
the access to arthroplasty procedures.
As it remains unproven that hypermobility of
the first tarsometatarsal joint (TMTJ-1) is a significant factor
in hallux valgus deformity, the necessity for including arthrodesis
of TMTJ-1 as part of a surgical correction of a hallux valgus is
questionable. In order to evaluate the role of this arthrodesis
on the long-term outcome of hallux valgus surgery, a prospective,
blinded, randomised study with long-term follow-up was performed,
comparing the Lapidus procedure (which includes such an arthrodesis)
with a simple Hohmann distal closing wedge metatarsal osteotomy. The
study cohort comprised 101 feet in 87 patients: 50 feet were treated
with a Hohmann procedure and 51 with a Lapidus procedure. Hypermobility
of TMTJ-1 was assessed pre-operatively by clinical examination.
After a mean of 9.25 years (7.25 to 11.42), 91 feet in 77 patients
were available for follow-up. There was no difference in clinical
or radiological outcome between the two procedures. Also, there
was no difference in outcome between the two procedures in the subgroup
clinically assessed as hypermobile. This study does not support
the theory that a hallux valgus deformity in a patient with a clinically
assessed hypermobile TMTJ-1 joint requires fusion of the first tarso-metatarsal
joint. Cite this article:
The August 2012 Knee Roundup360 looks at: meniscal defects and a polyurethane scaffold; which is best between a single or double bundle; OA of the knee; how to resolve anterior knee pain; whether yoga can be bad for your menisci; metal ions in the serum; whether ACI is any good; the ACL; whether hyaluronic acid delays collagen degradation; and hyaluronan and patellar tendinopathy.
The August 2013 Foot &
Ankle Roundup360 looks at: mobility, ankles and fractures; hindfoot nailing: not such a bad option after all?; little treatment benefit for blood injection in tendonitis; fixed bearing ankles successful in the short term; hindfoot motion following STAR ankle replacement; minimally invasive calcaneal fracture fixation?; pes planus in adolescents; and subluxing peroneals and groove deepening
Noise generation has been reported with ceramic-on-ceramic
articulations in total hip replacement (THR). This study evaluated
208 consecutive Delta Motion THRs at a mean follow-up of 21 months
(12 to 35). There were 141 women and 67 men with a mean age of 59
years (22 to 84). Patients were reviewed clinically and radiologically,
and the incidence of noise was determined using a newly described
assessment method. Noise production was examined against range of
movement, ligamentous laxity, patient-reported outcome scores, activity
level and orientation of the acetabular component. There were 143
silent hips (69%), 22 (11%) with noises other than squeaking, 17
(8%) with unreproducible squeaking and 26 (13%) with reproducible
squeaking. Hips with reproducible squeaking had a greater mean range
of movement (p <
0.001) and mean ligament laxity (p = 0.004), smaller
median head size (p = 0.01) and decreased mean acetabular component
inclination (p = 0.02) and anteversion angle (p = 0.02) compared
with the other groups. There was no relationship between squeaking
and age (p = 0.13), height (p = 0.263), weight (p = 0.333), body
mass index (p = 0.643), gender (p = 0.07) or patient outcome score
(p = 0.422). There were no revisions during follow-up. Despite the
surprisingly high incidence of squeaking, all patients remain satisfied
with their hip replacement. Cite this article:
Our study aimed to examine if a mobile-bearing total knee replacement
(TKR) offered an advantage over fixed-bearing designs with respect
to rates of secondary resurfacing of the patella in knees in which
it was initially left unresurfaced. We examined the 11-year report of the New Zealand Joint Registry
and identified all primary TKR designs that had been implanted in
>
500 knees without primary resurfacing of the patella. We examined
how many of these were mobile-bearing, fixed-bearing cruciate-retaining
and fixed-bearing posterior-stabilised designs. We assessed the rates
of secondary resurfacing of the patella for each group and constructed
Kaplan-Meier survival curves.Objectives
Methods
The August 2013 Shoulder &
Elbow Roundup360 looks at: the sternoclavicular joint revisited; surgical simulators: more than just a fancy idea?; arthroscopic tennis elbow release; costly clavicle stabilisation; a better treatment for tennis elbow?; shock news: surgeons and radiologists agree; overhead athletes and SLAP repair; and total shoulder arthroplasty more effective than hemiarthroplasty
Lateral epicondylitis, or ’tennis elbow’, is
a common condition that usually affects patients between 35 and
55 years of age. It is generally self-limiting, but in some patients
it may continue to cause persistent symptoms, which can be refractory
to treatment. This review discusses the mechanism of disease, symptoms
and signs, investigations, current management protocols and potential
new treatments. Cite this article:
Version of the femoral stem is an important factor
influencing the risk of dislocation after total hip replacement (THR)
as well as the position of the acetabular component. However, there
is no radiological method of measuring stem anteversion described
in the literature. We propose a radiological method to measure stem
version and have assessed its reliability and validity. In 36 patients
who underwent THR, a hip radiograph and CT scan were taken to measure
stem anteversion. The radiograph was a modified Budin view. This
is taken as a posteroanterior radiograph in the sitting position
with 90° hip flexion and 90° knee flexion and 30° hip abduction.
The angle between the stem-neck axis and the posterior intercondylar
line was measured by three independent examiners. The intra- and
interobserver reliabilities of each measurement were examined. The
radiological measurements were compared with the CT measurements
to evaluate their validity. The mean radiological measurement was
13.36° ( Cite this article:
We prospectively assessed the efficacy of a ceramic-on-metal
(CoM) hip bearing with uncemented acetabular and femoral components
in which cobalt–chrome acetabular liners and alumina ceramic heads
were used. The cohort comprised 94 total hip replacements (THRs) in 83 patients
(38 women and 45 men) with a mean age of 58 years (42 to 70). Minimum
follow-up was two years. All patients had pre- and post-operative
assessment using the Western Ontario and McMaster Universities osteoarthritis
index (WOMAC), Oxford hip score and Short-Form 12 scores. All showed
a statistically significant improvement from three months post-operatively
onwards (all p <
0.001). After two years whole blood metal ion levels were measured and
chromosomal analysis was performed. The levels of all metal ions
were elevated except vanadium. Levels of chromium, cobalt, molybdenum
and titanium were significantly higher in patients who underwent
bilateral THR compared with those undergoing unilateral THR (p <
0.001).
Chromosomal analysis demonstrated both structural and aneuploidy
mutations. There were significantly more breaks and losses than
in the normal population (p <
0.001). There was no significant
difference in chromosomal aberration between those undergoing unilateral
and bilateral procedures (all analyses p ≥ 0.62). The use of a CoM THR is effective clinically in the short-term,
with no concerns, but the significance of high metal ion levels
and chromosomal aberrations in the long-term remains unclear. Cite this article:
While an increasing amount of arthroplasty articles
report comorbidity measures, none have been validated for outcomes.
In this study, we compared commonly used International Classification
of Diseases-based comorbidity measures with re-operation rates after
total hip replacement (THR). Scores used included the Charlson,
the Royal College of Surgeons Charlson, and the Elixhauser comorbidity
score. We identified a nationwide cohort of 134 423 THRs from the
Swedish Hip Arthroplasty Register. Re-operations were registered
post-operatively for up to 12 years. The hazard ratio was estimated
by Cox’s proportional hazards regression, and we used C-statistics
to assess each measure’s ability to predict re-operation. Confounding
variables were age, gender, type of implant fixation, hospital category,
hospital implant volume and year of surgery. In the first two years only the Elixhauser score showed any significant
relationship with increased risk of re-operation, with increased
scores for both one to two and three or more comorbidities. However,
the predictive C-statistic in this period for the Elixhauser score
was poor (0.52). None of the measures proved to be of any value between
two and 12 years. They might be of value in large cohort or registry
studies, but not for the individual patient. Cite this article:
Some surgeons are reluctant to perform a reverse
total shoulder arthroplasty (RTSA) on both shoulders because of concerns
regarding difficulty with activities of daily living post-operatively
as a result of limited rotation of the shoulders. Nevertheless,
we hypothesised that outcomes and patient satisfaction following
bilateral RTSA would be comparable to those following unilateral
RTSA. A single-surgeon RTSA registry was reviewed for patients who underwent
bilateral staged RTSA with a minimum follow-up of two years. A unilateral
RTSA matched control was selected for each shoulder in those patients
undergoing bilateral procedures. The Constant–Murley score (CMS), American
Shoulder and Elbow Surgeons (ASES) score, Subjective Shoulder Values
(SSV), visual analogue scale (VAS) for pain, range of movement and
strength were measured pre- and post-operatively. The mean CMS,
ASES, SSV, VAS scores, strength and active forward elevation were
significantly improved
(all p <
0.01) following each operation in those undergoing bilateral
procedures. The mean active external rotation (p = 0.63 and p =
0.19) and internal rotation (p = 0.77 and p = 0.24) were not significantly
improved. The improvement in the mean ASES score after the first
RTSA was greater than the improvement in its control group (p =
0.0039). The improvement in the mean CMS, ASES scores and active
forward elevation was significantly less after the second RTSA than
in its control group (p = 0.0244, p = 0.0183, and p = 0.0280, respectively).
Pain relief and function significantly improved after each RTSA
in those undergoing a bilateral procedure. Bilateral RTSA is thus a reasonable form of treatment for patients
with severe bilateral rotator cuff deficiency, although inferior
results may be seen after the second procedure compared with the
first. Cite this article:
In this prospective study a total of 80 consecutive
Chinese patients with Crowe type I or II developmental dysplasia of
the hip were randomly assigned for hip resurfacing arthroplasty
(HRA) or total hip replacement (THR). Three patients assigned to HRA were converted to THR, and three
HRA patients and two THR patients were lost to follow-up. This left
a total of 34 patients (37 hips) who underwent HRA and 38 (39 hips)
who underwent THR. The mean follow-up was 59.4 months (52 to 70)
in the HRA group and 60.6 months (50 to 72) in the THR group. There was
no failure of the prosthesis in either group. Flexion of the hip
was significantly better after HRA, but there was no difference
in the mean post-operative Harris hip scores between the groups.
The mean size of the acetabular component in the HRA group was significantly
larger than in the THR group (49.5 mm vs 46.1 mm, p = 0.001). There was
no difference in the mean abduction angle of the acetabular component
between the two groups. Although the patients in this series had risk factors for failure
after HRA, such as low body weight, small femoral heads and dysplasia,
the clinical results of resurfacing in those with Crowe type I or
II hip dysplasia were satisfactory. Patients in the HRA group had
a better range of movement, although neck-cup impingement was observed.
However, more acetabular bone was sacrificed in HRA patients, and
it is unclear whether this will have an adverse effect in the long
term.
We report the results of revision total knee
replacement (TKR) in 26 patients with major metaphyseal osteolytic defects
using 29 trabecular metal cones in conjunction with a rotating hinged
total knee prosthesis. The osteolytic defects were types II and
III (A or B) according to the Anderson Orthopaedic Research Institute
(AORI) classification. The mean age of the patients was 72 years
(62 to 84) and there were 15 men and 11 women. In this series patients had
undergone a mean of 2.34 previous total knee arthroplasties. The
main objective was to restore anatomy along with stability and function
of the knee joint to allow immediate full weight-bearing and active
knee movement. Outcomes were measured using Knee Society scores,
Oxford knee scores, range of movement of the knee and serial radiographs.
Patients were followed for a mean of 36 months (24 to 49). The mean
Oxford knee clinical scores improved from 12.83 (10 to 15) to 35.20
(32 to 38) (p <
0.001) and mean American Knee Society scores
improved from 33.24 (13 to 36) to 81.12 (78 to 86) (p <
0.001).
No radiolucent lines suggestive of loosening were seen around the trabecular
metal cones, and by one year all the radiographs showed good osteo-integration.
There was no evidence of any collapse or implant migration. Our
early results confirm the findings of others that trabecular metal
cones offer a useful way of managing severe bone loss in revision
TKR. Cite this article:
The aim of this study was to determine whether there is any significant
difference in temporal measurements of pain, function and rates
of re-tear for arthroscopic rotator cuff repair (RCR) patients compared
with those patients undergoing open RCR. This study compared questionnaire- and clinical examination-based
outcomes over two years or longer for two series of patients who
met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR
patients. All surgery was performed by a single surgeon. Objectives
Methods
Early total hip replacement (THR) for acetabular
fractures offers accelerated rehabilitation, but a high risk of heterotopic
ossification (HO) has been reported. The purpose of this study was
to evaluate the incidence of HO, its associated risk factors and
functional impact. A total of 40 patients with acetabular fractures
treated with a THR weres retrospectively reviewed. The incidence
and severity of HO were evaluated using the modified Brooker classification,
and the functional outcome assessed. The overall incidence of HO
was 38%
(n = 15), with nine severe grade III cases. Patients who underwent
surgery early after injury had a fourfold increased chance of developing
HO. The mean blood loss and operating time were more than twice
that of those whose surgery was delayed (p = 0.002 and p <
0.001,
respectively). In those undergoing early THR, the incidence of grade
III HO was eight times higher than in those in whom THR was delayed
(p = 0.01). Only three of the seven patients with severe HO showed
good or excellent Harris hip scores compared with eight of nine
with class 0, I or II HO (p = 0.049). Associated musculoskeletal
injuries, high-energy trauma and head injuries were associated with
the development of grade III HO. The incidence of HO was significantly higher in patients with
a displaced acetabular fracture undergoing THR early compared with
those undergoing THR later and this had an adverse effect on the
functional outcome. Cite this article:
The development of tibiofemoral angle in children has shown ethnic
variations. However this data is unavailable for our population. We measured the tibiofemoral angle (TFA) and intercondylar and
intermalleolar distances in 360 children aged between two and 18
years, dividing them into six interrupted age group intervals: two
to three years; five to six years; eight to nine years; 11 to 12
years; 14 to 15Â years; and 17 to 18 years. Each age group comprised
30 boys and 30 girls. Other variables recorded included standing
height, sitting height, weight, thigh length, leg length and length
of the lower limb.Objectives
Methods
Femoroacetabular impingement (FAI) causes pain
and chondrolabral damage via mechanical overload during movement
of the hip. It is caused by many different types of pathoanatomy,
including the cam ‘bump’, decreased head–neck offset, acetabular
retroversion, global acetabular overcoverage, prominent anterior–inferior
iliac spine, slipped capital femoral epiphysis, and the sequelae
of childhood Perthes’ disease. Both evolutionary and developmental factors may cause FAI. Prevalence
studies show that anatomic variations that cause FAI are common
in the asymptomatic population. Young athletes may be predisposed
to FAI because of the stress on the physis during development. Other
factors, including the soft tissues, may also influence symptoms and
chondrolabral damage. FAI and the resultant chondrolabral pathology are often treated
arthroscopically. Although the results are favourable, morphologies
can be complex, patient expectations are high and the surgery is
challenging. The long-term outcomes of hip arthroscopy are still
forthcoming and it is unknown if treatment of FAI will prevent arthrosis.
The aim of this study was to perform a cost–utility
analysis of total hip (THR) and knee replacement (TKR). Arthritis is
a disabling condition that leads to long-term deterioration in quality
of life. Total joint replacement, despite being one of the greatest
advances in medicine of the modern era, has recently come under
scrutiny. The National Health Service (NHS) has competing demands,
and resource allocation is challenging in times of economic restraint. Patients
who underwent THR (n = 348) or TKR (n = 323) between January and
July 2010 in one Scottish region were entered into a prospective
arthroplasty database. A health–utility score was derived from the
EuroQol (EQ-5D) score pre-operatively and at one year, and was combined
with individual life expectancy to derive the quality-adjusted life years
(QALYs) gained. Two-way analysis of variance was used to compare
QALYs gained between procedures, while controlling for baseline
differences. The number of QALYs gained was higher after THR than
after TKR (6.5 Cite this article: